• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 249
  • 78
  • 59
  • 33
  • 26
  • 14
  • 13
  • 6
  • 5
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 592
  • 116
  • 69
  • 58
  • 55
  • 51
  • 42
  • 40
  • 39
  • 36
  • 36
  • 35
  • 34
  • 31
  • 31
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

MODELING AND CONTROL OF MAGNETOSTRICTIVE ACTUATORS

Zhang, Wei 01 January 2005 (has links)
Most smart actuators exhibit rate-dependant hysteresis when the working frequency is higher than 5Hz. Although the Preisach model has been a very powerful tool to model the static hysteresis, it cannot be directly used to model the dynamic hysteresis. Some researchers have proposed various generalizations of the Preisach operator to model the rate-dependant hysteresis, however, most of them are application-dependant and only valid for low frequency range. In this thesis, a first-order dynamic relay operator is proposed. It is then used to build a novel dynamic Preisach model. It can be used to model general dynamic hysteresis and is valid for a large frequency range. Real experiment data of magnetostrictive actuator is used to test the proposed model. Experiments have shown that the proposed model can predict all the static major and minor loops very well and at the same time give an accurate prediction for the dynamic hysteresis loops. The controller design using the proposed model is also studied. An inversion algorithm is developed and a PID controller with inverse hysteresis compensation is proposed and tested through simulations. The results show that the PID controller with inverse compensation is good at regulating control; its tracking performance is really limited (average error is 10 micron), especially for high frequency signals. Hence, a simplified predictive control scheme is developed to improve the tracking performance. It is proved through experiments that the proposed predictive controller can reduce the average tracking error to 2 micron while preserve a good regulating performance.
112

Control of Hysteresis in the Landau-Lifshitz Equation

Chow, Amenda January 2013 (has links)
There are two main tools for determining the stability of nonlinear partial differential equations (PDEs): Lyapunov Theory and linearization. The former has the advantage of providing stability results for nonlinear equations directly, while the latter considers the stability of linear equations and then further justification is needed to show the linear stability implies local stability of the nonlinear equation. Linearization has the advantage of investigating stability on a simpler equation; however, the justification can be difficult to prove. Both Lyapunov Theory and linearization are applied to the Landau--Lifshitz equation, a nonlinear PDE that describes the behaviour of magnetization inside a magnetic object. It is known that the Landau-Lifshitz equation has an infinite number of stable equilibrium points. We present a control that forces the system from one equilibrium to another. This is proved using Lyapunov Theory. The linear Landau--Lifshitz equation is also investigated because it provides insight to the nonlinear equation. The linear model is shown to be well--posed and its eigenvalue problem is solved. The resulting eigenvalues suggest an appropriate control for the nonlinear Landau--Lifshitz equation. Mathematically, the control causes the initial equilibrium to no longer be an equilibrium and the second point to be an asymptotically stable equilibrium point. This implies the magnetization has moved to the second equilibrium and hence the control objective is successfully achieved. The existence of multiple stable equilibria is closely related to hysteresis. This is a phenomenon that is often characterized by a looping behaviour; however, the existence of a loop is not sufficient to identify hysteretic systems. A more precise definition is required, which is presented, and applied to the Landau--Lifshitz equation (both linear and nonlinear) to establish the presence of hysteresis.
113

Experimental Investigation of Wind-Forced Drop Stability

Schmucker, Jason 2012 August 1900 (has links)
The stability of drops forced by both wind and gravity is a fluid mechanics problem relevant to heat exchangers, fuel cells, and aircraft icing. To investigate this phenomenon, drops from 15 micro-liters to 400 micro-liters were placed on the rough aluminum (RA = 3.26 micrometers) floor of a tiltable wind tunnel and brought to critical conditions, when the drop begins to run downstream. Various combinations of drop size, inclination angle, and flow speed were employed. A measurement technique capable of measuring full 3D drop profiles was implemented to investigate the drops' evolution toward runback. The measurement requires the comparison of the speckle pattern captured by an overhead drop image with a corresponding image of the dry surface. Stability limits for 235 drops are measured as functions of drop volume and surface inclination. Drops experiencing airflow alone are found to shed at a Weber number of 8.0 +/- 0.5. From measurement sequences of reconstructed drop profiles, the evolution of contact lines, drop profiles, and contact angle distributions are detailed. Contact line integral adhesion forces are calculated from contact angle distributions and related to the forcing air velocity. Drops whose stability limits are dominated by gravity are found to exhibit significantly different evolution toward runback than those dominated by airflow.
114

BIOELECTRICAL IMPEDANCE ANALYSIS OF MUSCLE FUNCTION AND ACTIVITY: (BIODYNAMIC ANALYSIS)

William Mccullagh Unknown Date (has links)
Abstract There is a need in medicine and research for noninvasive, painless, safe and simple bed-side techniques to measure physiological processes associated with muscle function and activity. Bioelectrical Impedance Analysis (BIA) is a widely used, noninvasive, painless, safe and simple procedure for the measurement of body composition. However, although capable of producing accurate and reproducible data, it is known to be prone to movement artifacts. This poses the interesting question “Could impedance changes be used to monitor movement and, consequently, be related to muscle function or activity?” This project investigated the utility of impedance change as a monitoring technique for physiological processes that involve movement such as muscular contraction, the calf muscle pump, and swallowing. The impedance of leg muscle segments during locomotion, whilst riding a stationary exercise cycle, was measured at discrete frequencies and by bioimpedance spectroscopy to monitor muscle function or activity. Impedance traces were compared to information obtained by electromyography (EMG). Impedance, at a discrete frequency, was able to measure the cadence of cycling and its magnitude was related to the position of the pedal during the pedal cycle. When the cycling action was measured by bioimpedance spectroscopy, R0 and Zc showed a statistically significant difference, (p<0.05), between all angles of the pedal crank cycle while R∞ showed a statistically significant difference between angles in the lower hemisphere of the pedal crank cycle. The cyclical changes in impedance during cycling may be attributed to changes in shape and volume of the muscle during contraction as well as a volume change due to blood and lymph being pumped from the limb by the action of the calf muscle pump. Based on procedures used in the cycling studies, an impedance-based method for the measurement of calf muscle pump function during an exercise protocol, originally designed for use with air plethysmography, was developed. It was shown that impedance measured at 5 kHz provides a simple, non-invasive method for the measurement of the ejection fraction and ejection volume of the calf muscle pump as well as other haemodynamic variables. The impedance-based method was less technically challenging than accepted volumetric methods, such as air plethysmography and strain gauge plethysmography, and non-invasive c.f. ambulatory venous pressure, enabling it to be used repeatedly. Muscle function and activity is not confined to the legs so impedance changes in the arm and forearm during exercise were measured. Impedance measurements, at discrete frequencies and using bioimpedance spectroscopy, of the forearm during contractions of the hand were able to distinguish the difference between a ramp and a pulse contraction. When the impedance of the arm and forearm were plotted against the angle of the forearm to the horizontal during a bicep curl, there was an hysteresis effect. Impedance traces of a bicep curl were compared to an EMG trace of the same action. The larynx is a hollow muscular organ situated in the front of the neck above the trachea consisting of a framework of cartilages bound together by muscles and ligaments. The two major functions of the larynx are deglutition and phonation. Dysphagia, which is becoming more prevalent as the population ages, is defined as difficulty in swallowing thin liquids such as water or juices which splash into the trachea because the patient is unable to control the thin liquid bolus. Aspiration pneumonia and dehydration can be prevented by using thickened liquids which allow patients to achieve a safer swallowing response, but it is difficult to assess this response without interfering with the swallowing process. Impedance pharynography (IPG) is a technique using BIA to monitor an impedance waveform of the swallowing process that presents no radiation hazard to the patient, is non-invasive and does not require specialist trained personnel to operate it. Resistance changes across the neck were measured while subjects swallowed solutions of different viscosities. The resistance changes were distinctive and reproducible for each of the solutions of different viscosities which were swallowed. Measuring the function of the larynx by this method could be useful in the diagnosis and treatment of dysphagia. In conclusion, the studies described in this thesis demonstrate the potential usefulness of the measurement of change in impedance as a measure of muscle activity. Impedance-based methods can measure volume changes associated with changes in cross-sectional area of the muscles involved in contraction as well as compartmental fluid changes caused by the force of the contraction on the surrounding tissues including the vasculature. In particular, measuring the ejection fraction and other haemodynamic variables of the calf muscle pump by impedance has the potential to become the method of choice in the future because it is easy to use, inexpensive, non-invasive, safe, and hygenic. Measuring resistance changes across the neck during swallowing yields distinctive waveforms with features corresponding to the physiological phases of the swallowing process as well as identifying distinctive swallowing patterns associated with the different viscosities of liquids swallowed. Function of the larynx and the associated diseases of the larynx will potentially be easier to diagnose and treat with a safe, non-invasive, inexpensive, portable bed-side method of assessment such as BIA.
115

BIOELECTRICAL IMPEDANCE ANALYSIS OF MUSCLE FUNCTION AND ACTIVITY: (BIODYNAMIC ANALYSIS)

William Mccullagh Unknown Date (has links)
Abstract There is a need in medicine and research for noninvasive, painless, safe and simple bed-side techniques to measure physiological processes associated with muscle function and activity. Bioelectrical Impedance Analysis (BIA) is a widely used, noninvasive, painless, safe and simple procedure for the measurement of body composition. However, although capable of producing accurate and reproducible data, it is known to be prone to movement artifacts. This poses the interesting question “Could impedance changes be used to monitor movement and, consequently, be related to muscle function or activity?” This project investigated the utility of impedance change as a monitoring technique for physiological processes that involve movement such as muscular contraction, the calf muscle pump, and swallowing. The impedance of leg muscle segments during locomotion, whilst riding a stationary exercise cycle, was measured at discrete frequencies and by bioimpedance spectroscopy to monitor muscle function or activity. Impedance traces were compared to information obtained by electromyography (EMG). Impedance, at a discrete frequency, was able to measure the cadence of cycling and its magnitude was related to the position of the pedal during the pedal cycle. When the cycling action was measured by bioimpedance spectroscopy, R0 and Zc showed a statistically significant difference, (p<0.05), between all angles of the pedal crank cycle while R∞ showed a statistically significant difference between angles in the lower hemisphere of the pedal crank cycle. The cyclical changes in impedance during cycling may be attributed to changes in shape and volume of the muscle during contraction as well as a volume change due to blood and lymph being pumped from the limb by the action of the calf muscle pump. Based on procedures used in the cycling studies, an impedance-based method for the measurement of calf muscle pump function during an exercise protocol, originally designed for use with air plethysmography, was developed. It was shown that impedance measured at 5 kHz provides a simple, non-invasive method for the measurement of the ejection fraction and ejection volume of the calf muscle pump as well as other haemodynamic variables. The impedance-based method was less technically challenging than accepted volumetric methods, such as air plethysmography and strain gauge plethysmography, and non-invasive c.f. ambulatory venous pressure, enabling it to be used repeatedly. Muscle function and activity is not confined to the legs so impedance changes in the arm and forearm during exercise were measured. Impedance measurements, at discrete frequencies and using bioimpedance spectroscopy, of the forearm during contractions of the hand were able to distinguish the difference between a ramp and a pulse contraction. When the impedance of the arm and forearm were plotted against the angle of the forearm to the horizontal during a bicep curl, there was an hysteresis effect. Impedance traces of a bicep curl were compared to an EMG trace of the same action. The larynx is a hollow muscular organ situated in the front of the neck above the trachea consisting of a framework of cartilages bound together by muscles and ligaments. The two major functions of the larynx are deglutition and phonation. Dysphagia, which is becoming more prevalent as the population ages, is defined as difficulty in swallowing thin liquids such as water or juices which splash into the trachea because the patient is unable to control the thin liquid bolus. Aspiration pneumonia and dehydration can be prevented by using thickened liquids which allow patients to achieve a safer swallowing response, but it is difficult to assess this response without interfering with the swallowing process. Impedance pharynography (IPG) is a technique using BIA to monitor an impedance waveform of the swallowing process that presents no radiation hazard to the patient, is non-invasive and does not require specialist trained personnel to operate it. Resistance changes across the neck were measured while subjects swallowed solutions of different viscosities. The resistance changes were distinctive and reproducible for each of the solutions of different viscosities which were swallowed. Measuring the function of the larynx by this method could be useful in the diagnosis and treatment of dysphagia. In conclusion, the studies described in this thesis demonstrate the potential usefulness of the measurement of change in impedance as a measure of muscle activity. Impedance-based methods can measure volume changes associated with changes in cross-sectional area of the muscles involved in contraction as well as compartmental fluid changes caused by the force of the contraction on the surrounding tissues including the vasculature. In particular, measuring the ejection fraction and other haemodynamic variables of the calf muscle pump by impedance has the potential to become the method of choice in the future because it is easy to use, inexpensive, non-invasive, safe, and hygenic. Measuring resistance changes across the neck during swallowing yields distinctive waveforms with features corresponding to the physiological phases of the swallowing process as well as identifying distinctive swallowing patterns associated with the different viscosities of liquids swallowed. Function of the larynx and the associated diseases of the larynx will potentially be easier to diagnose and treat with a safe, non-invasive, inexpensive, portable bed-side method of assessment such as BIA.
116

BIOELECTRICAL IMPEDANCE ANALYSIS OF MUSCLE FUNCTION AND ACTIVITY: (BIODYNAMIC ANALYSIS)

William Mccullagh Unknown Date (has links)
Abstract There is a need in medicine and research for noninvasive, painless, safe and simple bed-side techniques to measure physiological processes associated with muscle function and activity. Bioelectrical Impedance Analysis (BIA) is a widely used, noninvasive, painless, safe and simple procedure for the measurement of body composition. However, although capable of producing accurate and reproducible data, it is known to be prone to movement artifacts. This poses the interesting question “Could impedance changes be used to monitor movement and, consequently, be related to muscle function or activity?” This project investigated the utility of impedance change as a monitoring technique for physiological processes that involve movement such as muscular contraction, the calf muscle pump, and swallowing. The impedance of leg muscle segments during locomotion, whilst riding a stationary exercise cycle, was measured at discrete frequencies and by bioimpedance spectroscopy to monitor muscle function or activity. Impedance traces were compared to information obtained by electromyography (EMG). Impedance, at a discrete frequency, was able to measure the cadence of cycling and its magnitude was related to the position of the pedal during the pedal cycle. When the cycling action was measured by bioimpedance spectroscopy, R0 and Zc showed a statistically significant difference, (p<0.05), between all angles of the pedal crank cycle while R∞ showed a statistically significant difference between angles in the lower hemisphere of the pedal crank cycle. The cyclical changes in impedance during cycling may be attributed to changes in shape and volume of the muscle during contraction as well as a volume change due to blood and lymph being pumped from the limb by the action of the calf muscle pump. Based on procedures used in the cycling studies, an impedance-based method for the measurement of calf muscle pump function during an exercise protocol, originally designed for use with air plethysmography, was developed. It was shown that impedance measured at 5 kHz provides a simple, non-invasive method for the measurement of the ejection fraction and ejection volume of the calf muscle pump as well as other haemodynamic variables. The impedance-based method was less technically challenging than accepted volumetric methods, such as air plethysmography and strain gauge plethysmography, and non-invasive c.f. ambulatory venous pressure, enabling it to be used repeatedly. Muscle function and activity is not confined to the legs so impedance changes in the arm and forearm during exercise were measured. Impedance measurements, at discrete frequencies and using bioimpedance spectroscopy, of the forearm during contractions of the hand were able to distinguish the difference between a ramp and a pulse contraction. When the impedance of the arm and forearm were plotted against the angle of the forearm to the horizontal during a bicep curl, there was an hysteresis effect. Impedance traces of a bicep curl were compared to an EMG trace of the same action. The larynx is a hollow muscular organ situated in the front of the neck above the trachea consisting of a framework of cartilages bound together by muscles and ligaments. The two major functions of the larynx are deglutition and phonation. Dysphagia, which is becoming more prevalent as the population ages, is defined as difficulty in swallowing thin liquids such as water or juices which splash into the trachea because the patient is unable to control the thin liquid bolus. Aspiration pneumonia and dehydration can be prevented by using thickened liquids which allow patients to achieve a safer swallowing response, but it is difficult to assess this response without interfering with the swallowing process. Impedance pharynography (IPG) is a technique using BIA to monitor an impedance waveform of the swallowing process that presents no radiation hazard to the patient, is non-invasive and does not require specialist trained personnel to operate it. Resistance changes across the neck were measured while subjects swallowed solutions of different viscosities. The resistance changes were distinctive and reproducible for each of the solutions of different viscosities which were swallowed. Measuring the function of the larynx by this method could be useful in the diagnosis and treatment of dysphagia. In conclusion, the studies described in this thesis demonstrate the potential usefulness of the measurement of change in impedance as a measure of muscle activity. Impedance-based methods can measure volume changes associated with changes in cross-sectional area of the muscles involved in contraction as well as compartmental fluid changes caused by the force of the contraction on the surrounding tissues including the vasculature. In particular, measuring the ejection fraction and other haemodynamic variables of the calf muscle pump by impedance has the potential to become the method of choice in the future because it is easy to use, inexpensive, non-invasive, safe, and hygenic. Measuring resistance changes across the neck during swallowing yields distinctive waveforms with features corresponding to the physiological phases of the swallowing process as well as identifying distinctive swallowing patterns associated with the different viscosities of liquids swallowed. Function of the larynx and the associated diseases of the larynx will potentially be easier to diagnose and treat with a safe, non-invasive, inexpensive, portable bed-side method of assessment such as BIA.
117

Trickle flow hydrodynamic multiplicity

Van der Merwe, Werner. January 2007 (has links)
Thesis (PhD.)(Chemical Engineering)--University of Pretoria, 2007. / Includes abstract. Includes bibliographical references.
118

Study of the magnetic field dependence of the critical current of Bi2Sr2CaCu208+x and (Bi, Pb)2Sr2Ca2Cu3O10+x superconducting tapes

Xu, Bin. Schwartz, Justin, January 2004 (has links)
Thesis (M.S.)--Florida State University, 2004. / Advisor: Dr. Cesar Luongo, Florida State University, College of Engineering, Dept. of Mechanical Engineering. Title and description from dissertation home page (viewed Sept. 23, 2004). Includes bibliographical references.
119

Hysteresis modeling of wood joints and structural systems /

Foliente, Greg C., January 1993 (has links)
Thesis (M.S.)--Virginia Polytechnic Institute and State University, 1993. / Vita. Abstract. Includes bibliographical references (leaves 105-113). Also available via the Internet.
120

Essays on growth, trade and producer heterogeneity

Irarrazabal, Alfonso A. January 2007 (has links)
Thesis (Ph. D.)--New York University, 2007. / Includes bibliographical references (leaves 174-177).

Page generated in 0.0369 seconds