• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 2
  • 2
  • Tagged with
  • 10
  • 10
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo do escoamento bifásico padrão golfada de líquido na transição vertical ascendente-horizontal utilizando um modelo slug-tracking / Study of two phase slug flow in the vertical upward-horizontal transition using a slug-tracking model

Barbosa Filho, Francisco Elpídio Vianna 17 August 2018 (has links)
Orientador: Ricardo Augusto Mazza / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-17T08:41:20Z (GMT). No. of bitstreams: 1 BarbosaFilho_FranciscoElpidioVianna_M.pdf: 5790999 bytes, checksum: fa54092632bda478168f180355312ced (MD5) Previous issue date: 2010 / Resumo: O escoamento bifásico padrão golfada de líquido é caracterizado pela passagem alternada de pistões de líquido seguidos por bolhas alongadas de gás. Este trabalho desenvolve um estudo experimental e numérico sobre este padrão de escoamento em uma tubulação contendo uma curva de 90 graus. Essa configuração permite a passagem do escoamento vertical ascendente para horizontal em uma curva com raio interno de 410 mm e diâmetro interno da tubulação de 26 mm. O arranjo experimental permite fazer a medição das propriedades do escoamento padrão golfada antes e depois da passagem pela curva. As grandezas medidas são: a velocidade de propagação das bolhas, os comprimentos de bolhas e pistões, a frequência de passagem e a queda de pressão ao longo da tubulação. Um modelo numérico do tipo slug-tracking é empregado para capturar as alterações das características dos pistões e das bolhas durante a transição vertical para horizontal. O modelo se concentra em capturar os efeitos da mudança de direção relacionados com: a força da gravidade, a aeração pistão líquido e a espessura do filme líquido que envolve as bolhas de gás alongada. Os resultados numéricos foram favoravelmente comparados em relação aos dados experimentais / Abstract: The slug flow pattern is characterized by the alternating passage of liquid slugs trailed by elongated gas bubbles. This work develops an experimental and numerical study in slug flow regime occurring in a 90 degree pipe bend. The pipe bend allows the transition from upward vertical flow to horizontal flow in a curve with inner radius of 410 mm and inside diameter of 26 mm. The experimental set up allows the measurement of the slug flow properties at the inlet and outlet of the pipe bend. The quantities measured are: bubble's nose velocity, bubble and slug lengths, the frequency of passage and the pressure drop. A numerical slug tracking model is employed to capture the changes of the slugs features during the vertical to horizontal transition. The modeling efforts concentrate on the effects of the change of direction on: the gravity force, liquid slug aeration and on liquid film thickness surrounding the elongated gas bubbles. The numerical results compare favorably against the experimental data / Mestrado / Termica e Fluidos / Mestre em Engenharia Mecânica
2

Impact of Piping Materials on Water Quality in Tegucigalpa, Honduras

Cerrato, Jose Manuel 28 September 2005 (has links)
The possible effects of pipe materials on drinking water quality have been analyzed in the distribution system of the water treatment plant of "La La Concepciónâ " in Tegucigalpa, Honduras. "La La Concepciónâ " is a surface water reservoir experiencing biogeochemical cycling of manganese. Black water problems have been reported in the distribution system since 1998. An evaluation of the potential influence that PVC and iron pipes could have on the concentration of iron and manganese in drinking water, the effects caused by the presence of manganese in PVC and iron pipe surfaces, and residual chlorine and Pb concentrations in the distribution system was performed. The sampled neighborhoods received an intermittent service. Water was suspended for 8 hours every day due to water quantity problems in the city. Water and pipe samples were obtained for PVC and galvanized iron pipes because these constitute the majority of the infrastructure used for distribution systems in Honduras. Thermodynamic and kinetic conditions for possible manganese oxidation by chlorine and dissolved oxygen in the distribution system were also evaluated. As expected, total Fe concentrations were greater for first flush conditions from the iron pipe. Water samples obtained from the PVC pipe showed higher total Mn concentrations and more black color than those obtained from the iron pipe for both first flush and continuous flow conditions. Residual chlorine decayed relatively fast along the sampled section of the distribution system. Pb concentrations were detected on water samples obtained from PVC for first flush and continuous flow and on iron pipe for first flush. Preliminary experiments showed that manganese-oxidizing and -reducing bacteria were present in the walls of both PVC and iron pipes. Higher numbers of colony-forming microorganisms were recovered from iron (30-fold more) compared to PVC pipe sections. However, the majority of isolates from the PVC biofilm (8 of 10, 80 %) were capable of Mn-oxidation while only 35 % (11 of 31) of isolates from the iron biofilm sample demonstrated Mn-oxidation. This research demonstrates the importance of the different interactions between water and the infrastructure used for its supply in producing safe drinking water. / Master of Science
3

An Optimization Study of an Intermittent-Flow Multistage Fluidized Ion Exchange Column with Fluid Diode Downcomers

Egan, Stephen Martin 10 1900 (has links)
<p> An optimization study of an intermittent-flow multistage fluidized ion exchange column was performed using a stochastic approximation method. A new type of downcomer, a fluid diode, was designed and employed to alleviate liquid bypassing through the downcomer. The well known ion exchange system, H⁺/Na⁺ exchange on Dowex 50W resin, was used in this work. </p> <p> The volumetric efficiency of the system was optimized with regard to certain column and diode parameters. A maximum volumetric efficiency of 71.8 hr⁻¹ was obtained for the following conditions: </p> <p> average liquid flowrate = 3661 ml/min ; </p> <p> resin flowrate = 56.1 gm/min ; </p> <p> plate spacing 11.43 cm ; </p> <p> lateral diode displacement= 0.794 cm. </p> <p> Experiments have shown that a 78.2% increase in volumetric efficiency was achieved by use of the fluidic diode downcomers. </p> / Thesis / Master of Engineering (ME)
4

[en] NUMERICAL SIMULATION OF A GAS-LIQUID MIXER FOR PUMPING STATIONS / [pt] SIMULAÇÃO NUMÉRICA DE UM MISTURADOR GÁS-LÍQUIDO PARA ESTAÇÕES DE BOMBEIO

LEONARDO CHAGAS CARBONE 26 January 2016 (has links)
[pt] A produção de petróleo offshore tem requerido cada vez mais a utilização de equipamentos de bombeio no leito marinho para a produção de poços a longas distâncias das unidades de produção. A grande maioria destes equipamentos tem dificuldade de operar com a presença de gás, ainda mais em condições de golfadas, onde a fração de vazio na sucção pode variar significativamente. Isto limita enormemente a janela operacional dos equipamentos. Uma forma de minimizar os efeitos das golfadas e, assim, ampliar a janela de operação destes equipamentos é a instalação de misturadores de fluxo na sucção das bombas, que atuam de forma a garantir uma maior sobrevida ao equipamento. Portanto, o projeto e a previsão do comportamento deste tipo de equipamento são fundamentais para bom funcionamento dos sistemas de bombeamento submarino. O presente trabalho investiga numericamente, com o modelo de dois fluidos, a eficiência de um tipo de misturador em uniformizar as frações de vazio. Diferentes configurações geométricas são analisadas e a influência das vazões de admissão de ambas as fases é discutida. A metodologia é validada através da comparação da queda de pressão através do misturador com dados experimentais disponíveis, onde se observou boa concordância. O modelo numérico mostra ainda que uma reserva de líquido é mantida no interior do equipamento e, o gás é forçado a se dispersar na corrente de líquido para sair do misturador. O comportamento do misturador frente à presença de golfadas também é investigado. Ao final do trabalho é proposta uma nova geometria, que se mostra mais tolerante a intermitências no escoamento. / [en] The offshore oil production is increasingly using pumping equipment at the seabed for production of wells at long distances from production units. Most of these devices have difficulty to operate in the presence of gas, especially in slug flow conditions, where the pump suction s void fraction can vary significantly. This problem limits the equipment s range of operation. One way to minimize the effects of slugging and thus enlarge the operation range of these devices is to use flow mixers at the pump s suction, which helps to ensure the operation even in the presence of large gas bubbles. Therefore, the design and prediction of the behavior of this type of equipment are essential for proper operation of subsea pumping systems. At the present work, the efficiency of a type of flow mixer to provide uniform void fractions at its outlet is numerically investigated, with the two fluid model. Different geometric configurations are analyzed and the influence of intake flow of both phases is discussed. The methodology is validated through comparison of the pressure drop through the flow mixer with available experimental data, where good agreement was observed. The numerical model also shows that a buffer of liquid is maintained inside the equipment and the gas is forced to disperse in the liquid stream to exit the mixer. The mixer s behavior in the presence of slugs is also investigated. Finally, a new geometry is proposed, which seems to be more efficient to avoid flow s intermittencies.
5

[pt] MEDIÇÃO DO CAMPO DE VELOCIDADE DO LÍQUIDO NO ESCOAMENTO BIFÁSICO, INTERMITENTE, EM DUTO HORIZONTAL, UTILIZANDO VELOCIMETRIA ESTEREOSCÓPICA / [en] STEREO-PIV LIQUID VELOCITY MEASUREMENTS IN TWO-PHASE, INTERMITENT FLOW IN A HORIZONTAL PIPE

16 August 2017 (has links)
[pt] Escoamentos intermitentes gás-líquido são encontrados em diversas aplicações de engenharia, como em linhas de produção de petróleo e em sistemas de refrigeração de reatores nucleares. O conhecimento detalhado deste padrão de escoamento é indispensável para a construção de modelos matemáticos representativos deste fenômeno físico complexo. No presente trabalho, foi desenvolvido um estudo experimental com o objetivo de fornecer informações que possibilitem a melhoria dos modelos existentes para o escoamento bifásico intermitente em duto horizontal. A técnica de velocimetria por imagem de partículas estereoscópica (SPIV) de alta frequência foi empregada, em conjunto com a técnica de fluorescência induzida por laser (LIF), permitindo a obtenção de campos de velocidade na região do pistão de líquido, a jusante da bolha alongada, e na região do filme líquido, a montante da bolha. O arranjo experimental possibilitou a medição das três componentes do vetor velocidade do escoamento bifásico água-glicerina e ar na seção transversal de uma tubulação horizontal de 40mm de diâmetro interno. Os resultados obtidos, originais na literatura, mostraram a evolução detalhada das três componentes dos campos médios do vetor velocidade ao longo da passagem da bolha alongada durante o escoamento intermitente. / [en] Gas-liquid intermittent flows can be found in many engineering applications, such as oil production lines and nuclear reactors cooling systems. The detailed knowledge of this flow pattern is necessary for the development of accurate mathematical models of this complex phenomenon. In this work, an experimental study was developed with the goal to provide data that could be used to improve the existing models for two-phase intermittent flow in horizontal pipes. The high-frequency stereoscopic particle image velocimetry (SPIV) technique was employed along with the laser induced fluorescence (LIF) technique, allowing the measurement of velocity fields in the liquid slug, downstream of the elongated bubble, and in the liquid film, upstream of the elongated bubble. The experimental arrangement allowed the measurement of the three components of the velocity vector in an intermittent two-phase water-glycerine and air flow, in a transversal sections of a 40mm internal diameter horizontal pipe. The results obtained revealed original detailed information on the evolution of the three components of the averaged velocity field associated with the passage of the elongated bubble characteristic of the intermittent flow.
6

Investigation of Spray Cooling Schemes for Dynamic Thermal Management

Yata, Vishnu Vardhan Reddy 05 1900 (has links)
This study aims to investigate variable flow and intermittent flow spray cooling characteristics for efficiency improvement in active two-phase thermal management systems. Variable flow spray cooling scheme requires control of pump input voltage (or speed), while intermittent flow spray cooling scheme requires control of solenoid valve duty cycle and frequency. Several testing scenarios representing dynamic heat load conditions are implemented to characterize the overall performance of variable flow and intermittent flow spray cooling cases in comparison with the reference, steady flow spray cooling case with constant flowrate, continuous spray cooling. Tests are conducted on a small-scale, closed loop spray cooling system featuring a pressure atomized spray nozzle. HFE-7100 dielectric liquid is selected as the working fluid. Two types of test samples are prepared on 10 mm x 10 mm x 2 mm copper substrates with matching size thick film resistors attached onto the opposite side, to generate heat and simulate high heat flux electronic devices. The test samples include: (i) plain, smooth surface, and (ii) microporous surface featuring 100 μm thick copper-based coating prepared by dual stage electroplating technique. Experimental conditions involve HFE-7100 at atmospheric pressure and 30°C and ~10°C subcooling. Steady flow spray cooling tests are conducted at flow rates of 2 - 5 ml/cm².s, by controlling the heat flux in increasing steps, and recording the corresponding steady-state temperatures to obtain cooling curves in the form of surface superheat vs. heat flux. Variable flow and intermittent flow spray cooling tests are done at selected flowrate and subcooling conditions to investigate the effects of dynamic flow conditions on maintaining the target surface temperatures defined based on reference steady flow spray cooling performance.
7

[pt] MEDIÇÃO DO CAMPO TRI-DIMENSIONAL DE VELOCIDADE DA FASE LÍQUIDA DE ESCOAMENTOS TURBULENTOS, GAS-LÍQUIDO, INTERMITENTES EM TUBO HORIZONTAL / [en] THREE-COMPONENT LIQUID VELOCITY FIELD MEASUREMENTS IN TURBULENT, GAS-LIQUID, INTERMITTENT FLOWS IN HORIZONTAL PIPES

RODRIGO DOS SANTOS NAVARRO DE MESQUITA 30 June 2020 (has links)
[pt] O estudo do escoamento intermitente de gás e líquido é de enorme relevância. Devido a sua vasta ocorrência em diversos problemas industriais, como na indústria do petróleo, em escoamentos de água e vapor em trocadores de calor e em sistemas de refrigeração de usinas nucleares, diversos estudos experimentais e numéricos buscam obter um conhecimento mais profundo deste complexo fenômeno. Devido a esta complexidade, se fazem necessários experimentos detalhados de maneira a dar suporte aos modelos matemáticos desenvolvidos. O presente trabalho descreve um estudo experimental de um escoamento turbulento gás-líquido no regime intermitente para tubo horizontal. As técnicas de velocimetria por imagem de partícula estereoscópica de alta frequência (SPIV ) e fluorescência induzida por laser (LIF) foram usadas para medir todos os três componentes do vetor de velocidade em diferentes seções do tubo, referenciadas pelo nariz da bolha de gás. A seção de testes consistiu de uma tubulação de acrílico com diâmetro interno de 40mm e 17,7m de comprimento. Os fluidos de trabalho utilizados foram água e ar, com velocidades superficiais de jL igual 0,3 0,4 e 0,5m/s e jG igual 0,5m/s que formaram o padrão de escoamento intermitente. Um sistema de sensores fotossensíveis foi utilizado para medir a velocidade de translação da bolha de gás, além de acionar o sistema SPIV. Desta forma, foi possível determinar os campos médios das três componentes de velocidade da fase líquida do escoamento turbulento gás-líquido em regiões de interesse na vizinhança da bolha alongada. Os dados obtidos revelaram a influência das bolhas de gás de maior velocidade, na dinâmica do campo de velocidade do líquido. Tais dados contém informações valiosas que contribuem não apenas para uma melhor compreensão da física que rege o escoamento, mas também como forma de validação e aprimoramento de modelos numéricos. / [en] The analysis of gas-liquid intermittent flow in horizontal pipes is of great relevance importance due its applications in many industrial problems, such as in the petroleum industry, boiler and heat exchanger tubes and cooling systems of nuclear power plants. A considerable number of experimental and analytical studies have been carried out on the pursuit of a deeper knowledge of this complex phenomenon. The present work describes an experimental study of a horizontal, gas-liquid pipe flow in the intermittent regime. Experimental techniques such as high frequency stereoscopic particle image velocimetry (SPIV ) and laser induced fluorescence (LIF), were applied in order to obtain all three components of the velocity vector at different pipe sections, referred to the gas bubble nose tip. A 40mm inner diameter, 17.7m long acrylic pipe was used as test section (L/D approximately 450). The working fluids, water and air formed the intermittent flow pattern, with superficial velocities of jL equal 0.3, 0.4 and 0.5 m/s and jG equal 0.5 m/s. A set of three photogate sensors, equally-spaced along the pipe, were used to measure the bubble translational velocities, and to trigger the SPIV system, allowing for the determination of ensemble-averaged, threecomponent velocity fields of the turbulent liquid flow in cross-stream planes around the gas bubble. The original data obtained revealed the influence of the faster-moving gas bubbles on the dynamics of the liquid velocity field, providing valuable information that contribute to a better understanding of the physics governing the flow, also serving for the validation of numerical simulations.
8

Conséquences de l’acclimatation à différents régimes thermiques sur les taux métaboliques standards des tacons du saumon de l’Atlantique(Salmo salar)

Beauregard, David 06 1900 (has links)
Les poissons vivant au sein d’une rivière sont soumis à des variations circadiennes de température pouvant influencer la croissance, la digestion et le métabolisme standard. Les modèles bioénergétiques utilisant les fonctions métaboliques pour déterminer la croissance d’un poisson ont souvent été élaborés avec des poissons acclimatés à des températures constantes. Ces modèles pourraient sous-estimer l’énergie dépensée par un poisson soumis à des températures fluctuantes. En utilisant la respirométrie par débit intermittent, les objectifs de ce travail étaient : (1) de quantifier les différences entre les taux métaboliques standards de poissons acclimatés à une température constante (20.2 oC ± 0.5 oC) et à des fluctuations circadiennes de température (19.8 oC ± 2.0 oC; 19.5 oC ± 3.0 oC) et (2) comparer deux méthodologies pour calculer les taux métaboliques standards de poissons sujets aux fluctuations circadiennes de températures : respirométrie (a) en température constante ou (b) en température fluctuante. Les poissons acclimatés à des fluctuations circadiennes de température ont des taux métaboliques standards plus élevés que des poissons acclimatés à une température constante. À 20.2 oC ± 0.5 oC, les taux métabolique standards ont été de 25% à 32% plus bas pour des poissons maintenus à une température constante que pour des poissons gardés sous des fluctuations circadiennes de température. Les méthodologies utilisées pour estimer les taux métaboliques standards de poissons sujets aux fluctuations de température offrent des résultats similaires. / Fish that inhabits river are subjected to circadian fluctuations in water temperature. These fluctuations can influence growth, digestion and metabolic processes. Bioenergetic models are traditionally modeled using data recorded from fish kept at constant water temperatures. These models could underestimate the energy spent by fish subjected to fluctuating temperatures. Thus, with intermittent-flow respirometry, the objectives of this study were to: (1) quantify the differences between standard metabolic rates of fish acclimatized to a constant temperature (20.2 oC ± 0.5 oC) and two circadian fluctuating temperatures (19.8 oC ± 2.0 oC; 19.5 oC ± 3.0 oC) and (2) compare two methodology for calculate standard metabolic rates of fish subjected to circadian fluctuating temperatures: intermittent-flow respirometry with (a) constant temperature or (b) fluctuating temperatures. Fish held at circadian fluctuating temperatures have higher standard metabolic rates than fish acclimatized to a constant temperature. At 20.2 oC ± 0.5 oC, standard metabolic rates was 25% to 32% lower for fish held at constant temperature than for fish held under circadian fluctuations. However, results of the two different strategies used to calculate standard metabolic rates of fish subjected to circadian fluctuating temperatures did not differ.
9

Conséquences de l’acclimatation à différents régimes thermiques sur les taux métaboliques standards des tacons du saumon de l’Atlantique(Salmo salar)

Beauregard, David 06 1900 (has links)
Les poissons vivant au sein d’une rivière sont soumis à des variations circadiennes de température pouvant influencer la croissance, la digestion et le métabolisme standard. Les modèles bioénergétiques utilisant les fonctions métaboliques pour déterminer la croissance d’un poisson ont souvent été élaborés avec des poissons acclimatés à des températures constantes. Ces modèles pourraient sous-estimer l’énergie dépensée par un poisson soumis à des températures fluctuantes. En utilisant la respirométrie par débit intermittent, les objectifs de ce travail étaient : (1) de quantifier les différences entre les taux métaboliques standards de poissons acclimatés à une température constante (20.2 oC ± 0.5 oC) et à des fluctuations circadiennes de température (19.8 oC ± 2.0 oC; 19.5 oC ± 3.0 oC) et (2) comparer deux méthodologies pour calculer les taux métaboliques standards de poissons sujets aux fluctuations circadiennes de températures : respirométrie (a) en température constante ou (b) en température fluctuante. Les poissons acclimatés à des fluctuations circadiennes de température ont des taux métaboliques standards plus élevés que des poissons acclimatés à une température constante. À 20.2 oC ± 0.5 oC, les taux métabolique standards ont été de 25% à 32% plus bas pour des poissons maintenus à une température constante que pour des poissons gardés sous des fluctuations circadiennes de température. Les méthodologies utilisées pour estimer les taux métaboliques standards de poissons sujets aux fluctuations de température offrent des résultats similaires. / Fish that inhabits river are subjected to circadian fluctuations in water temperature. These fluctuations can influence growth, digestion and metabolic processes. Bioenergetic models are traditionally modeled using data recorded from fish kept at constant water temperatures. These models could underestimate the energy spent by fish subjected to fluctuating temperatures. Thus, with intermittent-flow respirometry, the objectives of this study were to: (1) quantify the differences between standard metabolic rates of fish acclimatized to a constant temperature (20.2 oC ± 0.5 oC) and two circadian fluctuating temperatures (19.8 oC ± 2.0 oC; 19.5 oC ± 3.0 oC) and (2) compare two methodology for calculate standard metabolic rates of fish subjected to circadian fluctuating temperatures: intermittent-flow respirometry with (a) constant temperature or (b) fluctuating temperatures. Fish held at circadian fluctuating temperatures have higher standard metabolic rates than fish acclimatized to a constant temperature. At 20.2 oC ± 0.5 oC, standard metabolic rates was 25% to 32% lower for fish held at constant temperature than for fish held under circadian fluctuations. However, results of the two different strategies used to calculate standard metabolic rates of fish subjected to circadian fluctuating temperatures did not differ.
10

Desenvolvimento de um simulador físico de gas lift intermitente e bombeio pneumático Zadson em escala de laboratório / Development of a physical simulator for intermittent gas lift and Zadson pneumatic pump in laboratory scale

Ochoa Lara, Ismael Orlando, 1987- 22 August 2018 (has links)
Orientador: Sérgio Nascimento Bordalo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica e Instituto de Geociências / Made available in DSpace on 2018-08-22T17:35:33Z (GMT). No. of bitstreams: 1 OchoaLara_IsmaelOrlando_M.pdf: 12454353 bytes, checksum: de02a7be086b8fd068a57b93d2f5270a (MD5) Previous issue date: 2013 / Resumo: Apesar dos avanços alcançados, alguns aspectos da operação do gas-lift intermitente (GLI) convencional permanecem inexplorados ou pouco estudados até o presente, como por exemplo, a concomitância de etapas do ciclo apresentada por Carvalho (2004), ou a estabilidade de ciclos em função da temporização da válvula motora e do ajuste da válvula operadora. Ao mesmo tempo, o bombeio pneumático de Zadson (BPZ) tem apresentado bons resultados em sua aplicação em campos no Brasil, motivando-se estudos para se desenvolverem simuladores computacionais para o projeto e análise destes sistemas. Neste trabalho, foi construído um simulador físico para os métodos GLI convencional e BPZ, para validar simuladores numéricos propostos anteriormente por outros autores. O aparato laboratorial é constituído por quatro conjuntos operacionais: o primeiro conjunto representa a coluna de produção do GLI convencional, o segundo conjunto representa a coluna do BPZ, o terceiro conjunto representa o acoplamento poço-reservatório e o quarto conjunto representa a injeção de gás comprimido. Para a medição, há transdutores de pressão localizados em vários pontos do aparato e tanques de medição do volume produzido. O sistema de aquisição de dados e atuação das válvulas operadora e motora é operado por uma placa micro-controlada. Testes foram realizados alterando-se as variáveis operacionais dos métodos. Como conclusões do trabalho foram identificadas a concomitância das etapas do ciclo GLI, avaliado o fallback para várias condições operacionais, estudada a estabilidade dos ciclos de GLI, e desenhado um mapa operacional das condições de um ciclo GLI regular. Além disso, foi testado o funcionamento de três modos de operação do BPZ / Abstract: Despite the advances achieved so far, some important aspects of the operation of the conventional intermittent gas-lift (IGL) remain unexplored or poorly studied, as for instance, the concurrency of cycle stages, as presented by Carvalho (2004), or the stability of cycles due to motor valve timing and adjustment of the gas-lift valve. At the same time, the Zadson pneumatic pump (ZPP) has presented good results in Brazilian fields, motivating studies to develop computational simulators for the design of this method. In the course of the present work, a physical simulator was built for the IGL and ZPP, to validate numerical simulators proposed by previous authors. The laboratory apparatus consists of four operational sets; the first set is the production column of conventional IGL, the second set is the column of ZPP, the third set represents the well-reservoir coupling and the fourth set is the injection of compressed gas. For measurement, there are pressure transducers located at various points of the apparatus and tanks for measuring the produced volume. The system of data acquisition and actuation of gas-lift and motor valves are operated by a microcontroller board. Tests were performed by changing the operating variables of the gas lift methods. The results of the study are: the identification of the concurrent stages during the IGL cycle, the fallback for various operating conditions, the stability of IGL cycles, and an operating map for the conditions of a stable IGL cycle. In addition, the operation of three lifting modes of the ZPP were tested / Mestrado / Explotação / Mestre em Ciências e Engenharia de Petróleo

Page generated in 0.448 seconds