21 |
Enhanced Boiling Heat Transfer on a Dendritic and Micro-Porous Copper StructureFurberg, Richard January 2011 (has links)
A novel surface structure comprising dendritically ordered nano-particles of copper was developed during the duration of this thesis research project. A high current density electrodeposition process, where hydrogen bubbles functioned as a dynamic mask for the materials deposition, was used as a basic fabrication method. A post processing annealing treatment was further developed to stabilize and enhance the mechanical stability of the structure. The structure was studied quite extensively in various pool boiling experiments in refrigerants; R134a and FC-72. Different parameters were investigated, such as; thickness of the porous layer, presence of vapor escape channels, annealed or non-annealed structure. Some of the tests were filmed with a high speed camera, from which visual observation were made as well as quantitative bubble data extracted. The overall heat transfer coefficient in R134a was enhanced by about an order of magnitude compared to a plain reference surface and bubble image data suggests that both single- and two-phase heat transfer mechanisms were important to the enhancement. A quantitative and semi-empirical boiling model was presented where the main two-phase heat transfer mechanism inside the porous structure was assumed to be; micro-layer evaporation formed by an oscillating vapor-liquid meniscus front with low resistance vapor transport through escape channels. Laminar liquid motion induced by the oscillating vapor front was suggested as the primary single-phase heat transfer mechanism. The structure was applied to a standard plate heat exchanger evaporator with varying hydraulic diameter in the refrigerant channel. Again, a 10 times improved heat transfer coefficient in the refrigerant channel was recorded, resulting in an improvement of the overall heat transfer coefficient with over 100%. A superposition model was used to evaluate the results and it was found that for the enhanced boiling structure, variations of the hydraulic diameter caused a change in the nucleate boiling mechanism, which accounted for the largest effect on the heat transfer performance. For the standard heat exchanger, it was mostly the convective boiling mechanism that was affected by the change in hydraulic diameter. The structure was also applied to the evaporator surface in a two-phase thermosyphon with R134a as working fluid. The nucleate boiling mechanism was found to be enhanced with about 4 times and high speed videos of the enhanced evaporator reveal an isolated bubble flow regime, similar to that of smooth channels with larger hydraulic diameters. The number and frequency of the produced bubbles were significantly higher for the enhanced surface compared to that of the plain evaporator. This enhanced turbulence and continuous boiling on the porous structure resulted in decreased oscillations in the thermosyphon for the entire range of heat fluxes. / QC 20111111
|
22 |
[en] EXPERIMENTAL DETERMINATION OF TRANSPORTATIONS COEFFICIENTS FOR ICE SLURRY IN PLATE HEAT EXCHANGERS / [pt] DETERMINAÇÃO EXPERIMENTAL DOS COEFICIENTES DE TRANSPORTE DA PASTA DE GELO EM TROCADORES DE CALOR DE PLACASLUIS CARLOS CASTILLO MARTINEZ 25 August 2005 (has links)
[pt] A pasta de gelo é uma mistura de água e um aditivo, com finas partículas de gelo, apresentando uma alta densidade de energia térmica. O principal motivo de sua utilização deve-se à combinação do aproveitamento do calor latente na mudança de fase com capacidade de ser bombeado. O presente
trabalho trata do estudo experimental sobre a transfe rência de calor e queda de pressão, com mudança de fase, utilizando uma mistura de propileno glicol - água com 13,8% de concentração em peso, num trocador de calor de placas com arranjo em U para 16 placas. Realizaram-se testes de troca de calor com
escoamento em paralelo e contra-corrente, para duas condições de fração mássica de gelo e números de
Reynolds para a pasta de gelo entre 150 e 425, com diferentes condições de carga térmica. Dos testes foram observados aumentos de até 25% no coeficiente global de troca calor, ao se incrementar a vazão e,
conseqüentemente, o número de Reynolds da pasta de gelo. Com o aumento da fração de gelo melhora-se a capacidade de resfriamento, diminuindo o número de Nusselt da pasta de gelo. O coeficiente global de troca, porém, começa a diminuir. Na literatura esta relação ainda não está bem definida. Alguns autores relatam ganhos, perdas ou indiferença no coeficiente global. Resultados do coeficiente global e do número
de Nusselt, nos modos paralelo e contra-corrente, não apresentaram grande diferença. A capacidade de resfriamento em contra-corrente foi maior, apresentando valores de efetividade cerca 10% acima dos
resultados observados no modo paralelo. Os fatores de atrito encontrados variaram entre 0,030 a 0,085, o
que concorda com os resultados apresentados por outros pesquisadores. Como era de se esperar, o fator de atrito diminui com o aumento da vazão mássica e de maneira inversa com o aumento da fração de gelo. / [en] Ice slurry is an aqueous solution from which ice crystals are formed. These crystals possess high energy density, in the form of latent heat. Furthermore, the fact of being a slurry makes it an excellent energy
carrier, for it can be easily pumped. The present work presents an experimental procedure to assess the heat transfer and the pressure loss, with phase change, using a mixture of propyleneglycol and water, 13.8% weight, in a U-plate heat exchanger with 16 plates. Tests were carried out for both parallel and counter-flow configurations of the heat exchanger, for two different mass fractions of ice and with
Reynolds numbers between 150 and 425 for the slurry. Different thermal loads were considered. The
experiments showed increases of up to 25% in the overall heat transfer coeficiente when the slurry flow is increased, with consequent increase in the Reynolds number. By increasing the ice fraction the cooling capacity is improved, reducing the Nusselt number. In the literature, this relationship is not clearly defined, as some authors show gains in the heat exchange coefficient, losses, and some others did not observe any influence on this parameter. Regarding the heat Exchange configuration, i.e., parallel or counter-flow, neither the heat exchange coefficient, nor the Nusselt number suffered major influence. The
effectiveness is up to 10% higher for the counter-flow configuration in comparison with the parallel
configuration. The figures found for the friction coefficient, between 0,030 and 0,085, are in good agreement with the literature. As expected, the friction coefficient decreases when the mass flow is increased, and increases when the ice fraction is increased.
|
23 |
Plynová tepelná čerpadla se spalovacím motorem / Gas heat pumps based on stroke engineBedřich, Miroslav January 2014 (has links)
The aim of this Diploma thesis is a description of gas heat pump (GHP) technology and the possibility of their usage in real life. Also units from the major manufactures of GHP units in the Czech Republic and abroad are evaluated from technical and economical point of view. The thesis as well includes a part where is decided if it is better to further develop GHP units with higher or lower performance. In the last part of thesis are cooling circuits designed for both lower and higher performance, than performance of existing GHP unit Polo 100. As a result, the units with higher performance are more perspective. Therefore heat plate exchangers, which serve as a condenser and an evaporator, are designed for unit with higher performance.
|
24 |
Vnitřní prostředí a výplně otvorů / Internal environment and windowsBuřič, Jan January 2016 (has links)
The aim this diploma thesis is the design of heating and hot water in the building of a primary school in Trhové Sviny. The first part dealt with the issue of indoor environment and windows. The second part deals with a separate proposal heating and hot water in primary school. As a heat source was designed gas boiler, the second variant hot transfer station. The third part consists of technical reports and drawings of the specified object. The fourth part deals with the assessment of surface condensation on the surface of the window panes.
|
25 |
Modélisation de l'encrassement en régime turbulent dans un échangeur de chaleur à plaques avec un revêtement fibreux sur les parois / Numerical modeling of fouling induced by turbulent flow in a plate heat exchanger with fibrous coating on the wallsSadouk, Hamza Chérif 15 June 2009 (has links)
Les transferts de chaleur par convection forcée turbulente dans une conduite plane partiellement remplie par un milieu poreux sont étudiés numériquement. L’étude concerne l’analyse de l’encrassement dans un canal plan représentatif d’un échangeur de chaleur à plaques. Un fluide, ayant un fort pouvoir encrassant, est considéré en régime turbulent. L’objectif de cette étude est de proposer une technique qui repose sur l’utilisation de matériaux fibreux comme capteur de particules pouvant réduire les méfaits de l’encrassement. Cela consiste à essayer de réduire la résistance d’encrassement en agissant sur les propriétés thermiques du dépôt. L’étude de la cinétique de l’encrassement permet de déterminer la loi de variation de l’épaisseur du dépôt au cours du temps. Cette équation est couplée aux équations de conservation. Un modèle de conductivité thermique effective (fluide, dépôt, fibres poreuses) a été choisi et le phénomène de colmatage de la matrice poreuse est considéré. L’apport du milieu poreux sur les performances de l’échangeur est analysé / A numerical study is carried out to investigate the forced convection heat transfer induced by a turbulent flow in a parallel plate channel partly filled with a porous or fibrous material. The study involves the analysis of fouling in a plate heat exchanger, represented by a parallel plate channel with a high fouling potential liquid flow in turbulent regime. The objective is to come out with a technical solution that relies on the use of fibrous materials capability to capture deposited particles, and therefore to reduce the fouling impacts within heat exchangers. This solution focuses on reducing the fouling resistance on wall surfaces by modifying the thermal properties of the deposit. The deposit thickness evolution is obtained through a kinetics model of fouling, which is coupled to the conservation equations. An effective thermal conduction model (liquid, deposit, porous material) is selected in order to account for fouling within the porous matrix. The benefits of porous material on heat exchanger performance are analyzed
|
26 |
Vytápění krytého bazénu / Heating of the indoor swimming poolMusílková, Julie January 2018 (has links)
Theme of diploma thesis is the heating of the indoor swimming pool. The thesis is departed to three parts. In the first part, there is a theoretical solution indoor climate of swimming pool. In the second part, there is a calculation solution of the project. Project solves heating of the indoor swimming pool. The last part is an experimental part. Theme of the experiment is measurement of temperature and relative humidity of the swimming pool.
|
Page generated in 0.0309 seconds