[en] LOSS OF CONTROL AND INADEQUATE VOLTAGE CONTROL ACTION IN THE EVALUATION OF VOLTAGE STABILITY CONDITIONS / [pt] PERDA E INADEQUAÇÃO DO CONTROLE DE TENSÃO NA AVALIAÇÃO DAS CONDIÇÕES DE ESTABILIDADE DE TENSÃO

OSCAR CUARESMA ZEVALLOS 03 February 2015 (has links)
[pt] Esta pesquisa está relacionada à avaliação das condições de estabilidade de tensão em pontos de operação do sistema elétrico. A modelagem de geradores / compensadores síncronos e compensadores estáticos são analisadas. Estabeleceram-se os melhores modelos com controle de tensão ativo e com perda do controle. A questão da adequação do controle de tensão foi tratada através da análise dos elementos da matriz de sensibilidade entre as grandezas controladoras e as tensões controladas. Os índices de estabilidade de tensão foram calculados. Em todos os casos, a perda de controle de tensão tem impacto negativo sobre as condições de estabilidade de tensão. Nos casos com ação de controle inadequada, independe da relação inversa entre grandeza controladora e tensão controlada, um aumento da tensão na barra controlada teve um impacto positivo sobre as condições de estabilidade de tensão, e uma diminuição da tensão na barra controlada teve impacto negativo sobre as condições de estabilidade de tensão. Esse é o resultado esperado também quando a ação de controle é adequada. / [en] This research is related to the evaluation of voltage stability conditions of operating points of the power system. It has been studied the modelling of synchronous generators/synchronous compensators and static var compensators. The best models were established with active voltage control and with loss of control. The issue of voltage control was treated through analysis of the matrix sensitivity elements between the controlling variables and voltages at controlled buses. The voltage stability indexes were evaluated. In all cases, control loss proved to have a negative impact on voltage stability conditions. In cases with inadequate control action, results are non-dependent of the opposed relation between the controlling variable and voltage at controlling bus, an increase on voltage at controlled busbar proved to have a positive impact on voltage stability conditions, and a decrease on voltage at controlled busbar proved to have a negative impact on voltage stability conditions. This is also expected when the control action is appropriate.

Page generated in 0.0518 seconds