Spelling suggestions: "subject:"[een] WATER FLOW"" "subject:"[enn] WATER FLOW""
51 |
The pattern of surface waves in a shallow free surface flowHoroshenkov, Kirill V., Nichols, Andrew, Tait, Simon J., Maximov, G.A. January 2013 (has links)
Yes / This work presents new water surface elevation data including evidence of the spatial correlation of water surface waves generated in shallow water flows over a gravel bed without appreciable bed forms. Careful laboratory experiments have shown that these water surface waves are not well-known gravity or capillary waves but are caused by a different physical phenomenon. In the flow conditions studied, the shear present in shallow flows generates flow structures, which rise and impact on the water-air interface. It is shown that the spatial correlation function observed for these water surface waves can be approximated by the following analytical expression W(rho) = e(-rho 2/2 sigma w2)COS(2 pi L-0(-1)rho). The proposed approximation depends on the spatial correlation radius, sigma(w), characteristic spatial period, L-0, and spatial lag, . This approximation holds for all the hydraulic conditions examined in this study. It is shown that L-0 relates to the depth-averaged flow velocity and carries information on the shape of the vertical velocity profile and bed roughness. It is also shown that sigma(w) is related to the hydraulic roughness and the flow Reynolds number.
|
52 |
Interregional Commodity and Virtual Water Trade: Impact of Changing Climate and Water SupplyGuliani, Manraj 19 May 2015 (has links)
No description available.
|
53 |
Effect of Surface State on Water Wetting and Carbon Dioxide Corrosion in Oil-water Two-phase FlowTang, Xuanping 26 July 2011 (has links)
No description available.
|
54 |
Development of kerosene–water two-phase up-flow in a vertical pipe downstream of A 90° bendHamad, Faik A., He, S., Khan, M. Khurshid, Bruun, Hans H. 27 December 2011 (has links)
No / The development of kerosene–water up-flow in a vertical pipe of 77.8 mm inner diameter and 4500 mm, length downstream of a 90◦bend, hasbeen investigated using a Pitot tube and dual optical probe. The CFD ANSYS Fluent 12.0 is used to model the flow and the results are comparedwith experimental data. The CFD provides detailed information on flow structure which is difficult to obtain in experiments. The experimentalmeasurements of the local parameters demonstrate that the single phase and two-phase flows reached the fully developed axisymmetricalconditions at L/D = 54. These results also show the severe asymmetry distributions of the two-phase flow parameters at the entrance region(L/D = 1). The predictions from Fluent are found to be in close agreement with experimental data for L/D ≥ 16 but there is a significant discrepancyat L/D = 1.
|
55 |
Experimental study of kerosene–water two-phase flow in a vertical pipe using hot-film and dual optical probesHamad, Faik A., Khan, M. Khurshid, Bruun, Hans H. 24 September 2012 (has links)
No / The local parameters for kerosene–water upward flow are measured in a vertical pipe of 77.8 mm inner diameter at 4200 mm from the inlet(L/D = 54) using hot-film and dual optical probes. The effect of superficial water velocity and volumetric quality on radial distribution of two-phaseflow parameters is investigated. The results show the following: (i) the profiles of volume fraction and drop frequency are very similar, and increasing superficial water velocity at low volumetric qualities (<18.6%) change the profile from a convex shape with peak at the pipe centreline to uniform then to concave shape with peak near the wall; (ii) the profiles of drop cut chord change from a parabolic shape with peak at centreline for lows uperficial water velocities to a flat shape at higher superficial water velocity, and the area-averaged drop diameter decreases with higher superficial water velocities for all volumetric qualities; (iii) velocity profiles for both phases have shapes similar to single phase flow, flatter at higher values of superficial water velocity and volumetric quality and centreline peaked at low superficial water velocities and volumetric qualities; (iv) the slip velocity decreases with radial distance having a peak at centreline and zero values near the wall; (v) introducing kerosene drops into single phasewater flow results in a sharp increase in turbulent intensity, particularly at low water velocity, and the difference between the single phase and two-phase flow turbulence intensities decreases with higher superficial water velocities and (vi) the results show that interfacial area concentration increased with higher volumetric quality and higher number of bubbles thereby increases the contact area between the two phases.
|
56 |
Optimal Operation of Water and Power Distribution NetworksSingh, Manish K. 12 1900 (has links)
Under the envisioned smart city paradigm, there is an increasing demand for the coordinated operation of our infrastructure networks. In this context, this thesis puts forth a comprehensive toolbox for the optimization of electric power and water distribution networks. On the analytical front, the toolbox consists of novel mixed-integer (non)-linear program (MINLP) formulations; convex relaxations with optimality guarantees; and the powerful technique of McCormick linearization. On the application side, the developed tools support the operation of each of the infrastructure networks independently, but also towards their joint operation. Starting with water distribution networks, the main difficulty in solving any (optimal-) water flow problem stems from a piecewise quadratic pressure drop law. To efficiently handle these constraints, we have first formulated a novel MINLP, and then proposed a relaxation of the pressure drop constraints to yield a mixed-integer second-order cone program. Further, a novel penalty term is appended to the cost that guarantees optimality and exactness under pre-defined network conditions. This contribution can be used to solve the WF problem; the OWF task of minimizing the pumping cost satisfying operational constraints; and the task of scheduling the operation of tanks to maximize the water service time in an area experiencing electric power outage. Regarding electric power systems, a novel MILP formulation for distribution restoration using binary indicator vectors on graph properties alongside exact McCormick linearization is proposed. This can be used to minimize the restoration time of an electric system under critical operational constraints, and to enable a coordinated response with the water utilities during outages. / Master of Science / The advent of smart cities has promoted research towards interdependent operation of utilities such as water and power systems. While power system analysis is significantly developed due to decades of focused research, water networks have been relying on relatively less sophisticated tools. In this context, this thesis develops Advanced efficient computational tools for the analysis and optimization for water distribution networks. Given the consumer demands, an optimal water flow (OWF) problem for minimizing the pump operation cost is formulated. Developing a rigorous analytical framework, the proposed formulation provides significant computational improvements without compromising on the accuracy. Explicit network conditions are provided that guarantee the optimality and feasibility of the obtained OWF solution. The developed formulation is next used to solve two practical problems: the water flow problem, that solves the complex physical equations yielding nodal pressures and pipeline flows given the demands/injections; and an OWF problem that finds the best operational strategy for water utilities during power outages. The latter helps the water utility to maximize their service time during power outages, and helps power utilities better plan their restoration strategy. While the increased instrumentation and automation has enabled power utilities to better manage restoration during outages, finding an optimal strategy remains a difficult problem. The operational and coordination requirements for the upcoming distributed resources and microgrids further complicate the problem. This thesis develops a computationally fast and reasonably accurate power distribution restoration scheme enabling optimal coordination of different generators with optimal islanding. Numerical tests are conducted on benchmark water and power networks to corroborate the claims of the developed formulations.
|
57 |
A Study of Flow Patterns and Surface Wetting in Gas-Oil-Water FlowKee, Kok Eng 24 September 2014 (has links)
No description available.
|
58 |
Improved implementation strategies to sustain energy saving measures on mine cooling systems / Philip MareMaré, Philip January 2015 (has links)
Reliable, efficient and cost-effective energy supply is crucial for economic and social development. Mining and industrial sectors consumed close to 37% of the total energy produced in the world during 2013. The South African power network is strained by the rapid expansion of mining, industrial and public sectors. Generation, transmission and distribution of electrical energy are in progress, but supply will not meet demand in the near future.
The South African electricity supplier needs capital for expansion. Electricity price increases have been significantly higher than increases in the gold price over the last few years. Mining companies are under pressure from government to improve their labour relations. They are obligated to spend money on local infrastructure development. Therefore, cost efficiency receives higher priority than ever before and requires an implementation strategy.
Cooling systems on mines proved to be significant electricity consumers. These systems lack integrated management and efficient and optimised control. Electricity demand can be reduced through implementation of energy saving measures on these cooling systems. Energy saving measures reduce the operational costs of mining to ensure that mines stay globally competitive. The identification of long-term challenges for energy saving measures is crucial.
Successful implementation of energy saving measures results in improved utilisation and performance of mine cooling systems. These measures must be maintained to ensure a
constant positive impact on reduced electrical energy consumption. The electrical energy savings are dependent on external factors, such as ambient conditions.
Improved implementation strategies of energy saving measures will prevent deterioration of utilisation and performance of the mine cooling systems. Monitoring and reporting of key performance indicators are crucial. Lack of integrated maintenance can lead to lost opportunities and the deterioration of equipment and machines.
The improved implementation strategies in two separate case studies proved sustainable savings of 1.73 MW and 0.66 MW respectively. The electricity cost savings for Mine A and Mine B are R8.8 million and R2.9 million respectively. These savings have been sustained for periods of seventeen and seven months respectively, indicating the value of the study. / MIng (Mechanical Engineering), North-West University, Potchefstroom Campus, 2015
|
59 |
Improved implementation strategies to sustain energy saving measures on mine cooling systems / Philip MareMaré, Philip January 2015 (has links)
Reliable, efficient and cost-effective energy supply is crucial for economic and social development. Mining and industrial sectors consumed close to 37% of the total energy produced in the world during 2013. The South African power network is strained by the rapid expansion of mining, industrial and public sectors. Generation, transmission and distribution of electrical energy are in progress, but supply will not meet demand in the near future.
The South African electricity supplier needs capital for expansion. Electricity price increases have been significantly higher than increases in the gold price over the last few years. Mining companies are under pressure from government to improve their labour relations. They are obligated to spend money on local infrastructure development. Therefore, cost efficiency receives higher priority than ever before and requires an implementation strategy.
Cooling systems on mines proved to be significant electricity consumers. These systems lack integrated management and efficient and optimised control. Electricity demand can be reduced through implementation of energy saving measures on these cooling systems. Energy saving measures reduce the operational costs of mining to ensure that mines stay globally competitive. The identification of long-term challenges for energy saving measures is crucial.
Successful implementation of energy saving measures results in improved utilisation and performance of mine cooling systems. These measures must be maintained to ensure a
constant positive impact on reduced electrical energy consumption. The electrical energy savings are dependent on external factors, such as ambient conditions.
Improved implementation strategies of energy saving measures will prevent deterioration of utilisation and performance of the mine cooling systems. Monitoring and reporting of key performance indicators are crucial. Lack of integrated maintenance can lead to lost opportunities and the deterioration of equipment and machines.
The improved implementation strategies in two separate case studies proved sustainable savings of 1.73 MW and 0.66 MW respectively. The electricity cost savings for Mine A and Mine B are R8.8 million and R2.9 million respectively. These savings have been sustained for periods of seventeen and seven months respectively, indicating the value of the study. / MIng (Mechanical Engineering), North-West University, Potchefstroom Campus, 2015
|
60 |
Effect of water maldistribution on cooling tower fill performance evaluationBertrand, Timothy Paul 03 1900 (has links)
Thesis (MScEng (Mechanical and Mechatronic Engineering))--University of Stellenbosch, 2011. / ENGLISH ABSTRACT: A 1.5 x 1.5 m2 counter-flow fill performance test facility is described in detail.
Instrumentation was selected and installed in the cooling tower fill test facility and
calibrated to ensure measurement accuracy. A facility control program was written
to simplify the operation of the test facility via a user interface. The program
calculates automatically the Merkel number and loss coefficients as measures of
fill thermal and flow performance respectively. A spray frame was designed and
manufactured to ensure uniform water distribution to the fill. The water
distribution through different fills with varying fill heights and different water
flow rates was measured. The water attached to the walls of the test facility was
examined.
Film, trickle and splash fills are tested in the upgraded test facility. The film and
trickle fill performance determined during testing is deemed acceptable as these
fills have minimal migration effects. Fills with poor distribution effects and large
migration of water towards the walls of the test facility, like the splash fill tested,
cannot to be tested accurately in a 1.5 x 1.5 m2 test section as the results do not
represent the performance of the fill in a relatively large cooling tower.
Other aspects examined were:
• air flow uniformity
• air fill bypass effects
• location of water inlet and outlet temperature measurement points
• location of pressure measurement probes.
It was determined that, in the current test facility:
• air uniformity is suitable for performance testing
• air bypass effects can be ignored for open fills and can be minimised for
dense fills by packing sponge between the fill and walls
• water inlet and outlet temperatures should be measured in the pipe-work,
resulting in a measurement method that is not influenced by the relative
weightings of each thermocouple
• pressure difference over the fill height measured by the pressure
measurement tap is independent of its location on the fill outlet plane
provided the pressure measurement points are perpendicular to the air
stream and are not against the walls. / AFRIKAANSE OPSOMMING: 'n 1.5 x 1.5 m² Teenvloei pakking werkverrigting toetsfasiliteit word in detail
beskryf. Instrumentasie is gekies en geïnstalleer in die koeltoring pakking
toetsfasiliteit en gekalibreer om akkuraatheid te verseker. 'n Fasiliteit beheer
program is geskryf om die gebruik van die toetsfasiliteit te vereenvoudig. Die
program het ‘n vriendelike gebruikers intervalk. Die program bereken outomaties
die Merkel-getal en verlies koëffisiënte as mate van pakking termiese- en vloeiwerksverrigting.
'n Sproeiraam is ontwerp en vervaardig om uniforme water
verspreiding aan die pakking te verseker. Die water verspreiding deur verskillende
pakkings met verskillende pakking hoogtes en water vloei snelhede is gemeet. Die
water aangeheg aan die mure van die toetsfasiliteit is ook ondersoek.
Film, druppel en spat pakkings word in die opgegradeerde toetsfasiliteit getoets.
Die film- en druppelpakking werksverrigting bepaal tydens die toetse is
aanvaarbaar, aangesien hierdie pakkings minimale migrasie effekte het. Pakking
met swak verspreiding effekte en 'n groot migrasie van water na die wande van die
toetsfasiliteit, soos gevind met die spatpakking toetse, kan nie met akkuraatheid in
'n 1.5 x 1.5 m² toets seksie getoets word nie omdat die resultate nie die
werkverrigting van die pakking verteenwoordig in 'n relatief groot koeltoring.
Ander aspekte wat ondersoek was:
• lugvloei uniformiteit
• lug omleiding effeckte
• die posisie van water in- en uitlaat temperatuur meetpunte
• posisie van die drukmeetapparaat.
Dit is vasgestel dat, in die huidige toetsfasiliteit
• lugvloei eenvormigheid geskik is vir prestasietoetsing
• lug omleiding effekte kan geïgnoreer word vir oop pakkings en kan
verklein word vir digte pakkings deur spons tussen die pakking en mure te
pak
• water inlaat- en uitlaattemperature behoort gemeet te word in die pypwerk
en lei tot 'n metings metode wat nie beïnvloed word deur die relatiewe
gewigte van elke thermokoppel nie
• die druk verskil gemeet deur die drupmeetpunte oor die pakkinghoogte is
onafhanklik van hul posisie op die pakkinguitlaatvlak op voorwaarde dat
die drukmeetpunte loodreg is teen die lugstroom en nie teen die mure nie.
|