• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] VIBRATION CONTROL OF SLENDER TOWERS WITH A PENDULUM ABSORBER / [pt] ABSORSOR PENDULAR PARA CONTROLE DE VIBRAÇÕES DE TORRES ESBELTAS

DIEGO ORLANDO 24 July 2006 (has links)
[pt] Nesse trabalho, estuda-se o desempenho de um absorsor pendular no controle de vibrações de torres altas e esbeltas, ocasionadas por carregamentos dinâmicos, tais como, por exemplo, cargas ambientais. Em virtude da possibilidade de oscilações de grande amplitude, considera- se na modelagem do problema a não-linearidade do pêndulo. O principal objetivo é estudar o comportamento do sistema torre-pêndulo, submetido a um carregamento harmônico, no regime não-linear, abordando-se aspectos gerais ligados à estabilidade dinâmica. Apresenta-se, inicialmente, a formulação necessária para obter o funcional de energia do sistema coluna-pêndulo, tanto para o caso linear quanto para o caso não-linear, do qual derivam-se as equações diferenciais parciais de movimento. A partir das equações lineares, obtêm-se as freqüências naturais e modos de vibração para alguns casos relevantes de coluna. A seguir, com base na análise modal do sistema coluna-pêndulo, deriva-se um modelo de dois graus de liberdade capaz de descrever com precisão o comportamento do sistema na vizinhança da freqüência fundamental da coluna, do qual obtêm-se as equações de movimento e as equações de estado não- lineares. Uma análise paramétrica detalhada das oscilações não-lineares do sistema coluna-pêndulo demonstra que o absorsor pendular passivo pode reduzir ou amplificar a resposta da coluna. No estudo da influência da não-linearidade geométrica do pêndulo, verifica-se a importância dessa na resposta do sistema, evidenciando que a nãolinearidade não pode ser desprezada nessa classe de problema. Por fim, com base nos resultados, propõe-se um absorsor pendular híbrido. Os estudos revelam que este controle é mais eficiente que o passivo e que não requer grande gasto de energia. / [en] In the present work the performance of a pendulum absorber in the vibration control of tall and slender towers, caused by dynamic loads, such as, environmental loads, is studied in detail. Due to the possibility of large amplitude oscillations, the non-linearity of the pendulum is considered in the modeling of the problem. The main objective of this research is to study the behavior of the tower-pendulum system, submitted to a harmonic load, in the nonlinear regimen, with emphasis on general aspects related to its dynamic stability. It is presented, initially, the formulation necessary for the derivation of the system´s energy functional, both for the linear and the nonlinear cases, from which the partial differential equations of motion are derived and the vibration frequencies and related vibration modes are obtained. Then, based on the modal analysis of the column-pendulum system, a two degrees of freedom model, capable of describing with precision the behavior of the system in the neighborhood of the fundamental frequency of the column is derived, from which the equations of motion and the nonlinear state-space equations are obtained. A detailed parametric analysis of the nonlinear oscillations of the system is carried out. It shows that the pendulum may reduce or amplify the response of the column. The results show a marked influence of the geometric not-linearity of the pendulum on the response of the system, showing that its not-linearity cannot be neglected in this class of problems. Finally, based on the results, a hybrid control approach is proposed. These studies show that this control strategy is more efficient than the passive control alone and that it does not require a large amount of energy.

Page generated in 0.0566 seconds