• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] DETERMINATION OF RARE EARTH ELEMENTS IN GEOLOGICAL SAMPLES BY INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY / [pt] DETERMINAÇÃO DE ELEMENTOS TERRAS RARAS EM AMOSTRAS GEOLÓGICAS POR ESPECTROMETRIA DE MASSA COM PLASMA INDUTIVAMENTE ACOPLADO

WENDY JOHANA SANDOVAL ROJANO 05 October 2020 (has links)
[pt] A distribuição de elementos de terras raras (REE) é representativa das rochas e solos que originalmente os contêm e é frequentemente usada como parâmetro geoquímico ou ambiental para identificação de fontes. Este trabalho propõe um novo método de preparo de amostras para a determinação de elementos de terras raras (REE) por espectrometria de massa de plasma acoplada indutivamente (ICPMS) em amostras ambientais com altas concentrações de Ba. O método consiste na diluição das amostras, obtidas após decomposição ácida em sistema aberto, com ácido sulfúrico 10 porcento (v/v) para a separação de Ba2positive como BaSO4. A remoção da interferência sobre os isótopos de Eu (151Eu and 153Eu) foi eficiente para concentrações de Ba superiores a 0,1 mg L-1. A exatidão e a precisão foram verificadas pela análise de tres materiais certificados, rocha basáltica (NIST 688), Geological Survey (Granite G-2) e sedimento marinho (MESS-3). A metodologia proposta foi aplicada ao pavimento asfáltico, à brita e ao material de referencia certificado. Adicionalmente, todas as amostras foram decompostas por fusão alcalina e as concentrações de elementos majoritários e Eu foram determinadas por espectrometria de emissão ótica de plasma acoplada indutivamente (ICP OES). Os resultados da Eu estavam de acordo com a metodologia proposta, e os limites de detecção (LOD) para REE variaram de 0,003 mg L-1 (Lu) a 0,010 mg L-1 (Gd). A distribuição de REE foi medida em sedimentos superficiais e amostras de testemunhos coletados na Baía de Sepetiba, entre junho e setembro de 2016. A faixa de concentração de SREE foi entre 25-496 mg kg-1. Esse monitoramento é importante para avaliar o impacto da urbanização e desenvolvimento rápido e não planejado de atividades antropogênicas, comuns em muitas áreas costeiras tropicais do Brasil. / [en] The distribution of rare earth elements (REE) is representative of the rocks and soils that originally contain them and it is often used as a geochemical or an environmental parameter for source identification. This thesis proposes a new method for the determination of rare earth elements (REE), by inductively coupled plasma mass spectrometry (ICP-MS), in challenging environmental samples with high Ba concentrations. The method consists in diluting the wet sample digests, obtained after acid decomposition in an open system, with 10 porcento (v/v) sulfuric acid for the separation of Ba2+ as BaSO4. The interference removal on both Eu isotopes (151Eu and 153Eu) was efficient for Ba concentrations higher than 0.1 mg L-1. Accuracy and precision were verified by analysis of two certified materials, NIST 688 Standard Reference Material of basalt rock, Geological Survey G-2 granite and marine sediment reference material (MESS-3) provided by the National Research Council in Canada (NRC) was used to evaluate the accuracy of the REE determination in marine sediments. The proposed methodology was applied to asphalt pavement and crushed stone. Additionally, for comparison, all samples were decomposed by fusion and major elements and Eu concentrations were determined by inductively coupled plasma optical emission spectrometry (ICP OES). The Eu results were in agreement with the proposed methodology, and limits of detection (LOD) for REE varied from 0.003 mg L-1 (Lu) to 0.010 mg L-1 (Gd). The distribution of REE was also measured in surface sediments and sediment core collected in Sepetiba Bay, between June and September of 2016. The range of SREE concentrations was established between 25-496 mg kg-1. This monitoring is important to evaluate the impact of the fast and unplanned urbanization and development of anthropogenic activities, common to many tropical coastal areas in Brazil.
2

[en] DETERMINATION OF NICKEL AND CHROMIUM IN GEOLOGICAL SAMPLES BY ISOTOPE DILUTION USING INDUCTIVELY COUPLED PLASMA MASS SPECTROMETRY. / [pt] DETERMINAÇÃO DE NÍQUEL E CROMO POR DILUIÇÃO ISOTÓPICA EM AMOSTRAS GEOLÓGICAS UTILIZANDO ESPECTROMETRIA DE MASSA COM PLASMA INDUTIVAMENTE ACOPLADO

LAIS NASCIMENTO VIANA 15 July 2020 (has links)
[pt] Os metais estão presentes em diversos materiais e muitos deles, como o níquel e o cromo, possuem papeis significativos em diversos setores industriais. A quantificação desses metais é importante tanto para obtenção de informações relevantes a respeito desses materiais, como para avaliação de possíveis contaminações ambientais. No presente trabalho, foram desenvolvidos métodos analíticos para a determinação de níquel e cromo em amostras de asfalto, brita e CAP por espectrometria de massa com plasma indutivamente acoplado usando calibração externa e diluição isotópica. Para a avaliação da exatidão dos métodos foram utilizados os materiais de referência certificados NIST 1084a e NBS 688. Como métodos de preparo de amostra, foram estudadas a decomposição ácida em bloco digestor, e a diluição em uma mistura de xileno/butanol na proporção 60:40 v:v (para amostras de óleo). Para a correção da interferência da espécie 40Ar12C positivo sobre o isótopo de 52Cr foi utilizada a célula de reação dinâmica com introdução de CH4 como gás de reação, o que reduziu de forma significativa o sinal de fundo característico para o isótopo de cromo. Os métodos desenvolvidos se mostraram eficientes na determinação dos metais. As recuperações obtidas para os SRMs se encontram entre 80-120 porcento. As concentrações médias, em mg kg-1 , encontradas para Ni pelos diferentes métodos nas amostras de CAP, brita e asfalto foram, respectivamente 39,9 mais ou menos 0,6, 6,7 mais ou menos 0,5 e 11,2 mais ou menos 0,8, enquanto para Cr as concentrações foram 1,8 mais ou menos 0,1, 15,3 mais ou menos 0,3, 16,6 mais ou menos 0,4. O sucesso da aplicação da diluição isotópica em amostras dissolvidas em solvente orgânico mostrou-se muito promissor, pois elimina a necessidade da decomposição ácida das matrizes tornando o preparo das amostras mais rápido e menos trabalhoso. / [en] Metals are present in several samples and many of them, such as nickel and chromium, have significant roles in several industry sectors. The quantification of these metals is important both for obtaining relevant information regarding these materials, and for evaluating possible environmental contaminations. In the present work, analytical methods were developed for the determination of nickel and chromium in asphalt, crushed stone and CAP samples by inductively coupled plasma mass spectrometry using both external calibration technique and isotopic dilution. To evaluate accuracy of the method, the certified reference materials NIST 1084a and NBS 688 were used. Two different methods of sample preparation were employed, block digestion and direct dilution in a xylene / butanol mixture using a 60:40 v:v ratio (for the oil samples). For the interference correction imposed by 40Ar12C over 52Cr, the dynamic reaction cell was used with CH4 as the reaction gas, which significantly reduced the characteristic background signal of the chromium isotope. The methods developed proved to be efficient in the determination of the metals in question. The recovery values obtained for the SRMs were between 80-120 percent. The average concentrations, in mg kg-1 , found for Ni by the different methods in CAP, crushed stone and asphalt samples were, respectively, 39,9 more or less 0,6, 6,7 more or less 0,5 and 11,2 more or less 0,8, while for Cr the concentrations were 1,8 more or less 0,1, 15,3 more or less 0,3, 16,6 more or less 0,4. The successful application of isotope dilution in samples dissolved in organic solvent is very promising because it eliminates the need for acid digestion, making the sample preparation faster and less labor intensive.

Page generated in 0.0442 seconds