Characterisation of coal slurries for introduction into ICP OES for multi-element determinationsMujuru, M, McCrindle, RI, Panichev, N 22 January 2009 (has links)
The characterisation and stability of coal slurries for introduction into an inductively coupled plasma
optical emission spectrometer (ICP OES) and the application of slurries in the analysis of coal was
investigated. The importance of rheology and the stability of the coal slurries on the analytical results
produced by ICP OES was demonstrated. The homogeneity and stability of various coal slurries were
characterised by sedimentation tests, scanning electron microscopy (SEM), zeta potential and viscosity
measurements. The porosities and surface areas of different South African coals and a mechanism for
the adsorption of the dispersants onto the coals were determined using low-temperature nitrogen
physisorption studies. The possibility of partially solubulising the coal in N,N-dimethylformamide
(DMF) was investigated. SEM indicated that DMF solubulised coal fines and that 0.1% (m/v) Triton
X-100 with 10% (v/v) DMFresulted in well dispersed slurries relative to other dispersants (glycerol, PEI
and water). Slurry analysis of coarse and ground coal in 0.1% (m/v) Triton X-100, showed that higher
emission intensities and better precision was obtained when using ground coal. This was confirmed by
lower RSDs (less than 5% for most of the elements analysed) relative to the unground, coarse coal.
Glycerol slurries gave higher RSDs (higher than 5% for most of the elements) most of the time, thus
negatively influencing the precision of measurement. Physisorption studies indicated that ground coal
had up to ten times higher surface areas than coarse coal. The higher surface areas for fine ground coals
suggested why they were better dispersed and thus better transported into the plasma, resulting in
higher emission signals. Zeta potentials indicated that for all dispersants, the coal particles were well
repelled from each other, although SEM pictures indicated better dispersion for 0.1% (m/v) Triton
X-100 with 10% (v/v) DMF. It was demonstrated that higher intensities and higher precision could be
obtained with well dispersed and stable coal slurries.
|
2 |
Slurry nebulization ICP-OES for the determination of Cu, Fe, Mg, Mn and Zn in bovine liverMokgalaka, NS, Wondimu, T, McCrindle, RI 17 November 2007 (has links)
A method that involves analysis of bovine liver by slurry nebulization and ICP-OES has been
developed. This method permits rapid and accurate determination of Cu, Fe, Mg, Mn and Zn in bovine liver.
Aliquots of freeze-dried and powdered bovine liver sample were dispersed in 2.0 M HNO3 and sonicated to
homogenize the resulting slurries. Bovine liver samples were also microwave digested or subjected to aqueous
extraction for comparison of analytical results. Concentrations of Cu, Fe, Mg, Mn and Zn in aqueous slurries, the
digests, and aqueous extracts were determined by the ICP-OES using external calibration curves. A student’s ttest
showed that the results obtained using the slurry method were in good agreement at 95 % confidence level
(CL) with those of microwave digestion or aqueous extraction techniques, except for Fe. To check the accuracy
and precision of the slurry method, a bovine liver CRM was analyzed and good agreement was achieved with the
certified values at 95 % CL. The results demonstrate inefficiency of aqueous extraction technique for complete
removal of Fe in bovine liver sample.
|
3 |
Desenvolvimento de metodologia para determinação de Ba, Ca, Mg e Na em amostras de petróleo por ICP OES após extração induzida por quebra de emulsãoTREVELIN, A. M. 29 October 2014 (has links)
Made available in DSpace on 2016-08-29T15:35:37Z (GMT). No. of bitstreams: 1
tese_8211_Alex Marcilino Trevelin.pdf: 2482801 bytes, checksum: a97ebee08956099a48e526b59100f9da (MD5)
Previous issue date: 2014-10-29 / Atualmente, a indústria petrolífera necessita de investigar concentrações de metais vestigiais em petróleo e seus produtos, devido aos vários problemas decorrentes de suas presenças. Assim, o presente trabalho visa o desenvolvimento de uma metodologia apropriada para a determinação de Ba, Ca, Mg e Na em petróleo por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) utilizando como tratamento preliminar das amostras a extração induzida por quebra de emulsão (EIQE). O método é baseado na formação de emulsões de óleo-em-água, com agitação vigorosa das amostras com uma solução Triton X-100 contendo HNO3 e posterior ruptura da emulsão por meio de aquecimento. Após a quebra da emulsão, duas fases foram obtidas: fase superior, que é uma fase orgânica que contém apenas o petróleo, e uma fase aquosa ácida que contém os metais extraídos. Os parâmetros que poderiam influenciar a extração foram avaliados, como por exemplo, a concentração e a natureza do agente surfactante (Triton X-100 e Triton X-114), a concentração de HNO3 e a temperatura. As melhores condições foram preparadas por mistura de 0.2 g de petróleo com 2 mL de solução Triton X-100 5 % m/v em 10 % v/v HNO3 com temperatura de 80 °C de quebra. Os metais foram determinados por ICP OES utilizando padrão inorgânico aquoso como calibração externa. Os limites de detecção para o Ba, Ca, Mg e Na foram iguais a 0.0058, 0.062, 0.0068, 0.29 μg g-1 e os limites de quantificação são 0.019, 0.21, 0.023, 0.97 μg g-1, respectivamente. Além disso, testes de recuperação foram realizados nas amostras com valores conhecidos dos metais sob a forma de padrões organometálicos, com resultados entre 99.5% a 103.9%, e também foi verificado padrão de referência NIST 1634c que apresentou concordância nos valores para Ba e Na. Essas características tornam o procedimento EIQE um potencial substituto para preparo de amostras de petróleo e posterior determinação de elementos traço em ICP OES.
|
4 |
Determinação Simultânea de Metais em Cachaças Utilizando Voltametria de Redissolução Com Eletrodos de Nanotubo de Carbono e Calibração Multivariada.FERREIRA, R. J. 29 June 2015 (has links)
Made available in DSpace on 2016-08-29T15:35:40Z (GMT). No. of bitstreams: 1
tese_8951_Romário Junior Ferreira.pdf: 2456499 bytes, checksum: 142e67c95a725fc2498e81dabccf27f2 (MD5)
Previous issue date: 2015-06-29 / Cachaças são destilados provenientes de cana de açúcar, gerando teores alcoólicos em faixas de porcentagem de 38% a 48% em volume. Devido a seu grande consumo no país e sua complexidade em constituição química, promoveu-se neste trabalho a determinação dos metais cobre, zinco, cadmio e chumbo, que em quantidades elevadas, são nocivos à saúde e ao metabolismo humano. Determinou-se as concentrações desses metais por meio da espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) e por voltametria de redissolução anódica com onda quadrada, onde as cachaças sofreram apenas uma acidificação para serem inseridas no ICP OES, sendo elas analisadas por voltametria em caráter in situ. Com as concentrações encontradas no ICP OES, juntamente com as correntes obtidas pela voltametria, desenvolveram-se duas metodologias quimiometricas para a previsão desses metais em amostras de cachaça. As determinações simultâneas desses metais foram construídas por meio das as Redes Neurais Artificiais (RNA) e os Mínimos Quadrados Parciais (PLS), utilizando as correntes obtidas pela voltametria utilizando eletrodos de mercúrio e carbono comerciais, e um eletrodo de nanotubo de carbono construído em laboratório. Antes do desenvolvimento dessas técnicas, pré-tratamentos estatísticos particulares foram desenvolvidos nos dados de corrente de voltametria, a fim de obter-se uma melhor resposta de previsão dos metais. Tanto para a voltametria quanto para o ICP OES, a determinação de chumbo fora ineficaz, podendo justificar que o limite de detecção dos aparelhos era maior que a concentração deste metal nas amostras. Após o desenvolvimento dos métodos quimiometricos, calculou-se o erro de predição (RMSEP) para todos os metais, tanto no PLS quanto nas redes neurais, além de uma construção de gráficos de correlação de valores obtidos pelo ICP OES pelos valores previstos pela quimiometria. Os valores de RMSEP foram significativos, informando que as redes neurais obtiveram os melhores resultados para este trabalho. A metodologia proposta é simples, rápido e pode ser facilmente utilizado para controle em laboratórios de qualidade, como um método de análise alternativa.
|
5 |
Utilização do Lodo Gerado no Tratamento Por Eletrocoagulação de Chorume Como Fonte de Nutrientes no Crescimento Inicial de Milho (zea Mays L.)BETIM, F. S. 28 March 2016 (has links)
Made available in DSpace on 2016-08-29T15:35:42Z (GMT). No. of bitstreams: 1
tese_9764_Fernando Silva Betim.pdf: 1495331 bytes, checksum: b41448f270e426dc58753a0014c5f3ab (MD5)
Previous issue date: 2016-03-28 / Os resíduos sólidos urbanos (RSU) em grandes lixões são um dos maiores problemas urbanos atuais. Dentre os produtos gerados, há o chorume, um contaminante derivado de processos físicos, químicos e bioquímicos da decomposição do RSU, que, no geral, é composto de matéria orgânica dissolvida, compostos orgânicos xenobióticos, macrocomponentes inorgânicos e metais altamente tóxicos. Dentre os possíveis tratamentos, destaca-se a eletrocoagulação. Após este tratamento, resta-se um lodo, no qual há matéria orgânica e diversos nutrientes, altamente importantes para a agricultura. O presente trabalho avaliou a utilização do lodo gerado nesse tratamento como fonte de nutrientes no crescimento inicial de milho. Dose equivalentes a 0, 5, 10, 20, 30 e 40 t ha-1 foram aplicadas em um latossolo e, após 30 dias, o milho foi semeado, sendo colhido após 30 dias. Utilizando-se as técnicas de ICP-OES e FAAS, foi verificado o aumento da disponibilidade de Na, K, Ca, Mg, Mn, Fe, Cu e Zn, no solo, e redução da fração tóxica do Al no mesmo. Já nas folhas de milho, observou-se aumento nos teores de Na, K, Mn e Fe, e redução do Ca e Mg. Não foram observados aumentos significativos na massa seca e altura das plantas. Também verificou-se bom linearidade, exatidão e LD e LQ adequados em ambas as técnicas de análise.
|
6 |
Prekoncentrační techniky pro stanovení uranu s využitím modifikovaných sorbentů. / Preconcentration Techniques for Determination of Uranium Using the Modified Sorbents.Moos, Martin January 2011 (has links)
The work has been focused on the preconcentration techniques for determination of uranium on the modified sorbent, with the final use of ICP-OES and ICP-MS. First ICP-OES at a wavelength of 385.958 nm was used for determination of uranium. Parameters were optimized and the effect of mineral acids (HCl, HNO3), tensides (Septonex, Ajatin) and organic reagents like (4-(2-pyridylazo)resorcinol, ammonium pyrrolidinedithiocarbamate, 8-hydroxyquinoline-5-sulphonic acid and 1,2-dihydroxyanthraquinone-3-sulphonic acid) was observed. For ICP-MS an isotope 238U was chosen. As an internal standard 209Bi (200 ?g•l-1) was used. Modified silica gel was used (Silicagel tethered with C18, C8 alkyls and phenyl) and two types of Amberlite XAD 4 and XAD 16 for the preconcentration of uranium (VI). Commercially produced Amberlite was modified as follows: Drying at 100 °C (24 hours), milled, minced sorbent was selected and fractionated to particles size ranging from 0.32 to 0.63 ?m and finally activated in methanol. The deionised water and Septonex (5•10-3 mol•l-1) at pH 8 were used for Amberlite conditioning. The optimal sorption of uranium (VI) proceeded at pH 8 in the presence of 4-(2-pyridylazo)resorcinol or ammonium pyrrolidinedithiocarbamate with Amberlite XAD-16 moreover with 1,2-dihydroxyanthraquinone-3-sulphonic acid. All organic reagents have mass concentration five time larger than uranium . For the elution of uranium the mixture of 1 mol•l-1 HNO3 with acetone (ratio of 1:1) was used. Acetone was evaporated and the final analysis performed using ICP-OES. The preconcentration of uranium (VI) using Silicagel-C18 conditioning was performed with ethanol, deionised water and Zephyraminu (5•10-4 mol•l-1) at pH 8. For the Silica-C8 and Silicagel-Phenyl the same conditioning procedure without zephyramin was used. Silica-C18 had the highest sorption efficiency with 1,2-dihydroxyanthraquinone-3-sulphonic acid, Silicagel-C8 with ammonium pyrrolidinedithiocarbamate and Silicagel-Phenyl with 8-hydroxyquinoline-5-sulfonic acid, all organic reagents have mass concentration five time larger than uranium concentration. As an optimal elution mixture acetone and ethanol (ratio of 1:1) in the presence of 1 mol•l-1 HCl was evaluated. Acetone and ethanol was evaporated and the final analysis was performed using ICP-MS. Silicagel-C18 was evaluate as the most effective in the presence of zephyramin and 1,2-dihydroxyanthraquinone-3-sulphonic acid. Sorption was also tested in the presence of 20 ?g•l-1 microelements (Be, V, Co, Ni, Y, Pb, Th, Cd) and in the presence of a defined concentrations of K, Na, Ca, Mg, Al and Fe. Direct analysis of uranium was carried out on samples of water from the river Ploucnice and Turonian aquifers containing uranium, 3,5 and 19,3 ?g•l-1. Different type of water required preconcentration of uranium (VI) on Silica-C18 in the presence of 1,2-dihydroxyanthraquinone-3-sulphonic acid and zephyramin. The analysis results gave statistically satisfactory results, which were confirmed using standard addition of 20 ?g•l-1.
|
7 |
[en] STUDY FOR DETERMINATION OF THE CA/P RATIO IN HYDROXYAPATITE BY SPECTROMETRIC METHODS / [pt] ESTUDO DA DETERMINAÇÃO DA RAZÃO CA/P EM HIDROXIAPATITA POR MÉTODOS ESPECTROMÉTRICOSSORAYA RODRIGUES DOS SANTOS 12 September 2012 (has links)
[pt] A hidroxiapatita (Hap) é um mineral bastante estudado, devido à sua excelente biocompatibilidade e similaridade química com a porção mineral do osso humano. A hidroxiapatita estequiométrica Ca10(PO4)6(OH)2, com razão Ca/P igual a 1,67, pode ser de origem natural ou sintética. Os processos de fabricação são os mais diversos e a qualidade do produto dependente da natureza dos reagentes e dos parâmetros utilizados no processo, sendo importante, posteriormente, a sua caracterização estrutural e elementar. O presente trabalho tem como objetivo estudar a determinação da razão Ca/P em hidroxiapatita utilizando duas técnicas analíticas distintas: espectrometria de absorção atômica de alta resolução com fonte contínua (HR-CS AAS) e espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES). No caso da HR-CS AAS, os parâmetros instrumentais estudados foram vazão de acetileno, altura do queimador, taxa de aspiração e em seguida, número de pixels e tempo de integração. Já na técnica de ICP-OES, os parâmetros foram taxa de aspiração, potência da radiofrequência e vazão do gás de nebulização. Foi realizada uma otimização multivariada e as condições ótimas para cada parâmetro estudado foram determinadas pela função desejabilidade. O meio de leitura por HR-CS AAS para o cálcio foi uma solução HNO3 0,2 por cento v/v e KCl 1 por cento m/v e, para o fósforo, HNO3 5 por cento e KCl 0,1 por cento, já por ICP OES só foi empregado o HNO3 nas concentrações já especificadas A maior contribuição à incerteza do resultado final foi devido às soluções de calibração. Uma amostra de hidroxiapatita, produzida no Laboratório de Biomateriais do Centro Brasileiro de Pesquisas Físicas (CBPF) apresentou resultados de suas razões molares concordantes quando analisada pelas técnicas empregadas neste trabalho. / [en] Hydroxyapatite is a widely studied mineral due to its excellent biocompatibility and chemical similarity with the mineral portion of human bone. Stoichiometric hydroxyapatite Ca10(PO4)6(OH)2 with a Ca/P ratio of 1.67 can be natural or synthetic. Its manufacturing processes are diverse and the final product depends on the mineral type and the parameters used in the process, and subsequent structural and elemental characterizations are important. This study aims to determine hydroxyapatite Ca/P ratios by using two different analytical techniques: HR-CS AAS and ICP OES. In the case of HR-CS AAS the following instrumental parameters were studied: acetylene flow rate, burner height, rate of aspiration, pixels and integration time. In the ICP-OES technique, the parameters were rate of aspiration, radiofrequency power and nebulizer gas flow rate. We performed a multivariate optimization and optimal conditions for each studied parameter were determined by the function of desirability. The HR-CS AAS measurements for calcium were conducted in a medium containing HNO3 0.2 per cent v/v and KCl 1 per cent m/v and, for phosphorous, a medium containing HNO3 5 per cent and KCl 0.1 per cent was used. For the ICP OES measurements we used only HNO3 at the concentrations specified above. The major contribution to the uncertainty of the final results was from the calibration solutions. A hydroxiapatite sample, produced in the Biomaterial Laboratory at the Brazilian Center for Physical Research (CBPF), presented compatible molar ratio results among themselves when analyzed by the techniques utilized in the present study.
|
8 |
Acoplamento das técnicas HPLC-ICP OES para separação e identificação de metaloproteínas em castanhas de caju / Coupling of LC-ICP OES techniques for separation and identification of metalloproteins in cashew nutsSiqueira, Bruno Menezes 02 September 2016 (has links)
O objetivo desse trabalho foi demonstrar a viabilidade do acoplamento entre as técnicas de cromatografia líquida de alta eficiência com a espectrometria de emissão óptica com plasma indutivamente acoplado (HPLC - ICP OES) em um equipamento da Thermo Fisher Scientific, visando análise de especiação elementar de espécies com maiores concentrações na amostra. A identificação de espécies moleculares associadas aos elementos Cu, Fe, Mg, e Zn em amostras de castanha de caju foi adotada como modelo para comprovar tal acoplamento. Para que o ICP OES pudesse adquirir sinais de emissão ao longo de um tempo determinado, ou seja, para que o equipamento pudesse coletar um sinal transiente, fundamental para o acoplamento HPLC - ICP OES, foi necessário executar algumas modificações. Para isso, foram feitas alterações na placa eletrônica principal do equipamento, e trocada sua caixa controladora de gases. Os parâmetros instrumentais do ICP OES foram otimizados em uma série de ensaios com o intuito de estabelecer e avaliar desempenho do instrumento e a robustez do método empregado nas análises de castanha de caju. Determinações das concentrações totais de Ca, Cu, Fe, Mg, Mn, Ni, e Zn foram feitas em amostras de castanha de caju e nos materiais de referência NIST 1515 e NIST 1547, apresentando uma exatidão do método aceitável, levando-se em consideração o preparo de amostra e a medida no ICP OES. As determinações totais elementares nas amostras de castanha de caju indicaram que os teores de Ca foram de (0,04 ± 0,01) % ; Cu (26,3 ± 5,0) mg kg-1; Fe (47,9 ± 8,8) mg kg-1; Mg (0,31 ± 0,04) %; Mn (25,6 ± 3,9) mg kg-1; Ni (24,8 ± 1,9) mg kg-1; Zn (66,3 ± 2,4) mg kg-1. Para identificação de espécies moleculares associadas aos elementos Cu, Fe, Mg, e Zn, foi feita nas amostras de castanha de caju uma extração de metais e proteínas utilizando-se de uma solução extrato de NaOH 1 mol L-1. O extrato ainda foi submetido à uma etapa de clean-up, com precipitação das proteínas com acetona e ressupenção das mesmas com tampão Tris-HCl, pH 7,4. As proteínas e metais ressupensos em tampão foram analisados no sistema HPLC ICP OES, em que a separação cromatográfica ocorreu através de uma coluna de exclusão por tamanho (SEC), a detecção molecular através do detector UV-Vis do HPLC, e a detecção elementar através do ICP OES. As espécies moleculares identificadas estão no intervalo de massa molecular compreendido entre 2 e 177 kDa, sendo que Cu, Fe e Zn apresentam associação com essas espécies moleculares. Foram monitorados ainda, no ICP OES, os sinais de intensidade de emissão de P e S. Esses elementos também apresentaram associação com espécies moleculares com peso molecular entre 2 e 177 kDa, sugerindo que essas espécies se tratam de metaloproteínas. / The aim of this study was to demonstrate the capability of coupling between liquid chromatography techniques of high efficiency with the optical emission spectrometry with inductively coupled plasma (HPLC - ICP OES) in an equipment of Thermo Fisher Scientific, aiming elemental speciation analysis of species with higher concentrations in the sample. The identification of molecular species associated with elements Cu, Fe, Mg and Zn in cashew nuts samples was adopted as a model to prove such coupling. For ICP OES could get emission signal through a certain time, so that the equipment could collect a transient signal, critical to the HPLC coupling - ICP OES, it was necessary to perform some modifications in the instrument. For this, changes were made to the main electronic board of the equipment and also changed their gas controller box. The instrumental parameters of the ICP OES were optimized in a series of tests in order to establish and evaluate performance of the instrument and the robustness of the method employed in cashew nut analysis. Determination of the total concentration of Ca, Cu, Fe, Mg, Mn, Ni and Zn were made in cashew sample and reference materials NIST 1515 and NIST in 1547, with an accuracy acceptable method, taking into account the sample preparation and measurement by ICP OES. The elemental total determinations in cashew nut samples indicated that Ca were (0.04 ± 0.01)%; Cu (26.3 ± 5.0) mg kg-1; Fe (47.9 ± 8.8) mg kg-1; Mg (0.31 ± 0.04)%; Mn (25.6 ± 3.9) mg kg-1; Ni (24.8 ± 1.9) mg kg-1; Zn (66.3 ± 2.4) mg kg-1. For the identification of molecular species associated with the elements Cu, Fe, Mg, and Zn was performed on samples of cashew nuts an extract of metals and proteins using an extract solution of NaOH 1 mol L-1. The extract was further subjected to one-step of clean-up with protein precipitation with acetone following by a resuspension with Tris-HCl buffer, pH 7.4. Proteins and metals resuspended in buffer, were analyzed in the HPLC - ICP OES system, wherein the chromatographic separation took place by a size exclusion column (SEC), the molecular detection by UV-Vis detector of HPLC, and elemental detection by ICP OES. The molecular species were identified in the molecular weight range between 2 and 177 kDa, and Cu, Fe and Zn are associated with these molecular species. Were also monitored in the ICP OES, P and S emission intensity signals. These elements also associated with molecular species having a molecular weight between 2 and 177 kDa, suggesting that this species are metalloproteins.
|
9 |
Otimização de métodos para a determinação de P, Pb e Si em gasolinas por ICP-OES / Optimization of methods for the determination of Pb, Si and P in gasolines by ICP-OESSantos, Sandra Patricia de Andrade Mariano 08 December 2017 (has links)
O objetivo deste trabalho foi desenvolver métodos para a determinação simultânea de Pb, Si e P em gasolinas por ICP OES em conformidade com a Agência Nacional de Petróleo (ANP). O mercado da gasolina no Brasil é regulado pela Agência Nacional do Petróleo (ANP) e pela Lei Federal 9.478/97 (Lei do Petróleo) e, conforme Resolução ANP n°40, de 25.10.2013, a determinação de chumbo é exigida quando houver suspeita de contaminação. O chumbo era adicionado, desde 1922 para elevar o índice antidetonante da gasolina, mas devido a sua toxicidade foi mundialmente substituído. A determinação do silício passou a ser exigida em 1 de Janeiro de 2014 nas gasolinas, porque frações leves contaminadas com silício, quando usadas como combustíveis, podem gerar problemas aos motores automotivos, uma vez que os aditivos antiespumantes, a base de oligômeros contendo silício, são adicionados durante o processo de refino. O fósforo é um aditivo estimulante da extração do petróleo, sua determinação também é exigida quando houver suspeita de contaminação, pois concentrações acima do limite máximo podem desativar os catalisadores dos carros. No preparo de amostras foram utilizadas duas estratégias, a primeira diluição da gasolina com solventes orgânicos 10% da gasolina e 90% de Premisolv-Constan, com a vantagem da int rodução direta, porém necessita câmara refrigerada e fluxo de O2. E preparo da amostra por emulsão tipo óleo/água (O/W), preparada utilizando 1 mL de gasolina com 3 mL de surfactante Tergitol TMN-6® (20% m v-1), o qual foi escolhido entre 4 surfactantes (TritonTM X-100,TritonTM X-114, TergitolTMTMN-6 e TergitolTM 15-S-9) por ter apresentado melhor desempenho na formação da emulsão e menor branco analítico. Essa segunda estratégia apresentou vantagens em relação a primeira, pois reduz a introdução da matéria orgânica para 10% e dispensa o uso de câmara especial e fluxo de O2. As amostras foram analisadas com a construção de curvas de adição padrão a fim de eliminar os efeitos de matriz. Também foram analisadas amostras dopadas com padrão orgânico nas concentrações dos limites estabelecidos pela Resolução ANP. As recuperações foram de 86% a 98% para Pb, 90% a 106% para Si e 86% a 110% para P. Portanto o método desenvolvido demonstrou a possibilidade da determinação simultânea de Si, Pb e P nos limites estabelecidos pela legislação (Pb = 5 mg LTM-1, P = 1,3 mg L-1 e Si limite máximo ainda não estabelecido) e está de acordo com a Química Verde e Gestão de Saúde Meio Ambiente e Segurança. / The objective of this work was to develop methods for the simultaneous determination of Pb, Si and P in gasoline by ICP-OES in accordance with the National Petroleum Agency (ANP). The Brazilian gasoline market is regulated by the National Petroleum Agency (ANP) and Federal Law 9.478 / 97 (Petroleum Law) and according to ANP Resolution No. 40, dated 10.25.2013, the determination of lead is required when there is suspected contamination. Lead was added since 1922 to raise the antiknock index of gasoline, but because of its toxicity it has been worldwide replaced. The determination of silicon was required on 1 January 2014 in gasoline. Light fractions contaminated with silicon, when used as fuel, can cause problems for automotive engines, since antifoaming additives, based on silicon-containing oligomers, are added during the refining process. Phosphorus is a stimulating additive to petroleum extraction; its determination is also required when contamination is suspected, as concentrations above the upper limit can deactivate the catalysts of the cars. In the preparation of samples, two strategies were used, the first dilution of gasoline with organic solvents 10% of the gasoline and 90% of Premisolv-Constan, with the advantage of direct introduction, however, requires refrigerated chamber and O2 flow. Preparation of the sample by oil / water (O / W) emulsion, using 1 ml of gasoline with 3 ml of Tergitol TMN-6 surf surfactant (20% m v-1), which was chosen among 4 surfactants (TritonTM X-100, TritonTM X-114, TergitolTM TMN-6 e TergitolTM 15-S-9), because it showed better performance in the formation of the emulsion and lower analytical blank. This second strategy presents advantages over the first one because it reduces the introduction of the organic matter to 10% and dispenses with the use of special chamber and O2 flow. Samples were analyzed by constructing standard addition curves to eliminate matrix effects. We also analyzed doped samples with organic standards in the concentrations of the limits established by ANP Resolution. The recoveries were 86% to 98% for Pb, 90% to 106% for Si and 86% to 110% for P. Therefore, the method developed demonstrated the possibility of simultaneous determination of Si, Pb and P within the limits established by the legislation (Pb = 5 mg L-1, P = 1,3 mg L-1 and Si maximum limit not yet established) and is in accordance with the Green Chemistry and Health Management Environment and Safety.
|
10 |
Desenvolvimento de métodos alternativos ao fire assay para a determinação Ag, Au e Pd em sucata eletrônica por ICP-OES e WDSXRF / Development of alternative methods to Fire Assay for the determination of Ag, Au and Pd in electronic scrap by ICP-OES and WDSXRFMargatho, Vinícius Salles 15 December 2017 (has links)
As sucatas eletrônicas são hoje consideradas como matéria prima de alto valor agregado e economicamente viável, devido à presença de metais preciosos (e.g. prata, ouro, platina e paládio) em sua composição. Em geral, a comercialização é baseada no teor de metais preciosos e cobre, sendo assim, as análises químicas desempenham papel fundamental nesse ambiente de negócios. O método mais empregado para esse tipo de análise, considerado padrão é o Fire Assay, que consiste na extração dos analitos da matriz tornando determinação final praticamente livre de interferências. Entretanto o Fire Assay é um método susceptível a erros sistemáticos devido ao grande número de etapas, lento, caro e ambientalmente insustentável devido à quantidade de reagentes utilizados e resíduos gerados (e.g. chumbo). Diante dessas importantes desvantagens, o desenvolvimento de métodos que apresentem exatidão, precisão, boa frequência analítica, custo e que gere poucos resíduos se tornam necessários para a melhoria do controle de qualidade desses materiais. Sendo assim, o objetivo dessa pesquisa foi o desenvolvimento de método para a determinação simultânea de Au, Ag e Pd por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) e espectroscopia de fluorescência de raios-x por comprimento de ondas (WDSXRF), usando diferentes estratégias de preparação de amostras. As sucatas eletrônicas se caracterizam por serem heterogêneas, além disso, o material possui grande quantidade de metais como Al, Cu e Fe na composição fazendo com que a comunição seja um elemento chave no método e determinante da frequência analítica. Considerando esta dificuldade as amostras foram moídas em moinho oscilatório de discos de em diferentes tempos a fim de se investigar a influencia do tamanho de partículas para estudo de representatividade e precisão além da influencia do tamanho de partículas nas determinações por WDSXRF devido ao efeito sombra. Para os analises por WDSXRF as amostras com 40 minutos de moagem e preparadas com fusão com ferro e enxofre demonstraram boas correlações quando comprados ao Fire Assay. As dissoluções das amostras para analises em ICP OES ocorreu em duas etapas, a 1ª com HNO3 (aquecimento em chapa) para evitar passivação do ouro e a 2ª com 10 ml de água régia, usando o programa do forno de micro-ondas, com rampa de 160 °C a 210 °C (30 min). Foi observado que o excesso de Cl- formou complexos que inibiram perdas de Ag+ pro precipitação. As soluções finais foram analisadas no ICP OES e as concentrações obtidas foram comparadas ao método de Fire Assay. O método proposto mostrou boa correção para todos os elementos ao método padrão. A reprodutibilidade para Au foi de 4,1% (n=15 amostras) e a recuperação média comparada ao método padrão foi de 102%. Com base nos resultados obtidos pode-se dizer que o método proposto é comparável ao Fire Assay quanto à precisão e limites de detecção, apresentando melhores respostas quanto à frequência analítica, custo e geração de resíduos / Electronic scraps are today considered as raw material of high added value and economically viable, due to the presence of precious metals (e.g. silver, gold, platinum and palladium) in your composition. In general, the marketing is based on the content of precious metals and copper, therefore, chemical analysis plays a key role in this business environment. The method employed for this kind of analysis, considered standard, is the Fire Assay, which consists of the extraction of analytes in the array, making final determination virtually free of interference. However the Fire Assay is a method susceptible to systematic errors due to the large number of steps, slow, expensive and environmentally unsustainable due to the amount of reagents used and waste generated (e.g. lead). On these important disadvantages, the development of methods which have accuracy, precision, good analytical cost and frequency that generate few residues become necessary for the improvement of the quality control of these materials. Therefore, the objective of this research was the development of method for the simultaneous determination of Au, Ag and Pd by optical emission spectrometry with inductively coupled plasma (ICP OES) and fluorescence spectroscopy for x-ray wavelengths (WDSXRF), using different sampling strategies. Electronic scraps are characterized for being heterogeneous, in addition, the material possesses large amount of metals such as Al, Cu and Fe in the composition so that the communication is a key element in determining the frequency and analytical method. Considering this difficulty the samples were ground into oscillatory grinder discs at different times in order to investigate the influence of the particle size for study of representativeness and accuracy beyond the influence of the particle size determination by WDSXRF due to the shadow effect. For the analysis by WDSXRF samples with 40 minutes of grinding and prepared with merger with iron and sulfur showed good correlations when purchased the Fire Assay. The dissolutions of the samples for analysis in ICP-OES occurred in two steps, first with HNO3 (heating plate) to avoid gold passivation and the 2nd with 10 ml of aqua regia, by using the microwave oven, with 160 °C ramp to 210 °C (30 min). It was observed that the excess of Cl-formed complex that inhibit loss of Ag+ by precipitation. The final solutions were analysed at the ICP OES and the concentrations obtained were compared to the method of Fire Assay. The proposed method showed good fix for all elements to the standard method. Reproducibility for Au was 4.1% (n = 15 samples) and the average recovery compared to the standard method was 102%. Based on the results obtained can be said that the proposed method is comparable to the Fire Assay for accuracy and limits of detection, showing best answers regarding the analytical frequency, cost and waste generation.
|