• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 133
  • 24
  • 22
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 203
  • 203
  • 47
  • 45
  • 35
  • 32
  • 31
  • 29
  • 27
  • 23
  • 22
  • 22
  • 22
  • 18
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

An?lise de sedimento de fundo: uma amostragem representativa do estu?rio Potengi/RN

Dantas, A?cia Seleide 02 September 2009 (has links)
Made available in DSpace on 2014-12-17T15:41:47Z (GMT). No. of bitstreams: 1 AeciaSD.pdf: 4171408 bytes, checksum: b9c9bc4aed8af7d73b5b0b74a8b69ab1 (MD5) Previous issue date: 2009-09-02 / The aim of this study is to quantify the presence of major and minor elements in the sediments of estuary Potengi. Four georeferenced sampling points were used in the study, at which sediment samples were collected in the channel of the river and on the right and left banks. In addition, dissolved oxygen, salinity and water conductivity were taken in situ at the time of sample collection. The percentage of organic matter, determined by gravimetry, and granulometric analysis of the sediment samples were conducted in the laboratory. To quantify the major and minor elements a prior test to open the sample was conducted with standard NIST 1646? estuarine sediment to choose the best methodology to be adopted. The sediment samples were dissolved in microwaves with nitric acid and chloridric acid, according to methodology proposed by US EPA 3051?. Quantitative analyses of the elements Al, Fe, Cd, Cr, Cu, Mn, Ni, Pb and Zn were conducted by inductively coupled plasma optical emission spectrometry (ICPOES). The results showed that the partial concentrations of the elements analyzed are below average worldwide shale levels, the standard described by Turekian and Wedepohl (1961) / Esse trabalho objetiva avaliar, por meio da quantifica??o, a presen?a dos elementos maiores e menores nos sedimentos do estu?rio Potengi. Para o estudo, foram definidos quatro pontos de amostragem georeferenciados, onde em cada um deles foram coletadas amostras de sedimento na calha do rio e nas margens esquerda e direita. Al?m disso, foram realizadas medidas de pH, oxig?nio dissolvido, salinidade e condutividade da ?gua in situ no momento da coleta. Em laborat?rio foram feitas determina??es da porcentagem de mat?ria org?nica por Gravimetria e an?lise granulom?trica nas amostras de sedimento. Para quantifica??o dos elementos maiores e menores foi realizado um teste pr?vio para abertura da amostra com um padr?o de sedimento estuarino NIST 1646a para escolha da melhor metodologia a ser adotada. As amostras de sedimento foram digeridas em microondas com ?cido n?trico e ?cido lor?drico segundo metodologia proposta pela US EPA 3051A. As an?lises quantitativas dos elementos Al, Fe, Cd, Cr, Cu, Mn, Ni, Pb e Zn foram realizadas por espectrometria de emiss?o ?tica com plasma acoplado indutivamente (ICP-OES). Atrav?s destas observou-se que as concentra??es parciais dos elementos analisados est?o abaixo do folhelho padr?o tomado como m?dia mundial descritas por Turekian e Wedepohl (1961)
22

Avaliação da concentração de metais e elementos traço em amostras de sedimento do reservatório Guarapiranga, Bacia do Alto Tietê, São Paulo, Brasil / Metal and trace element sediment assessment from Guarapiranga reservoir, alto tietê basin, São Paulo, Brasil

Guilherme Moura Guimarães 15 June 2011 (has links)
O reservatório Guarapiranga está localizado na região metropolitana de São Paulo, Brasil, e é responsável pelo abastecimento de cerca de 20% das necessidades de água da população dessa região, aproximadamente 3,7 milhões de pessoas. Contudo, esse sistema tem apresentado significante degradação em sua qualidade de água, devido ao recebimento de esgotos domésticos não tratados e efluentes industriais. Nesse estudo amostras de sedimentos foram coletadas em cinco pontos ao longo do reservatório e a concentração total de alguns elementos maiores (Fe, K e Na), traço (As, Ba, Br, Co, Cr, Cs, Hf, Rb, Sb, Sc, Ta, Tb, Th, U, V e Zn) e terras raras (Ce, Eu, La, Lu, Nd, Sm, Tb e Yb) foram determinadas pela técnica de Análise por Ativação Neutrônica Instrumental (INAA). Utilizando-se a técnica de Espectrometria de Emissão Ótica com Plasma Acoplado Indutivamente (ICP OES) as concentrações dos elementos Al, Ba, Be, Ca, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Na, Ni, Pb, Ti, V e Zn foram determinadas após a digestão ácida dos sedimentos de acordo com a metodologia US EPA 3051. As determinações dos metais Cd e Pb foram feitas por espectrometria de absorção atômica com forno de grafite (GFAAS) e a de Hg total, por espectrometria de absorção atômica com geração de vapor frio (CVAAS). A validação das três metodologias analíticas, em termos de precisão e exatidão, foi feita por meio da análise de materiais de referência certificados. Os resultados obtidos por INAA foram comparados aos valores de referência do NASC (North American Shale Composite), UCC (Upper Continental Crust) e de solos coletados na região do parque da Guarapiranga. O fator de enriquecimento (FE) e o índice de geoacumulação (Igeo) foram calculados para esses dados. As concentrações dos metais obtidos por ICP OES e AAS foram comparadas aos valores orientadores TEL e PEL do Conselho Canadense de Ministros do Meio Ambiente (CCME) e adotados pela CETESB. Os resultados foram também comparados aos valores de referência regionais (VRR) de sedimentos límnicos da Bacia do Alto Tietê. A partir desses dados foi possível realizar uma avaliação do acúmulo de metais e elementos traço nos sedimentos do reservatório e verificar a possibilidade desses elementos interferirem, adversamente, na biota e na qualidade da água desse ambiente. / The Guarapiranga Reservoir, located in São Paulo metropolitan region, Brazil, is responsible for supplying about 20% of the entire populations water needs of this region or approximately 3.7 million people. However, this system has shown significant degradation in water quality, due to untreated domestic sewage and industrial effluents. In this study sediment samples were collected at five points along the reservoir and total concentration of some major (Fe, K and Na), trace (As, Ba, Br, Co, Cr, Cs, Hf, Hg, Rb, Sb, Sc, Ta, Tb, Th, U, V and Zn) and rare earth (Ce, Eu, La, Lu, Nd, Sm, Tb and Yb) elements were determined by instrumental neutron activation analysis (INAA). By inductively coupled plasma optical emission spectrometry (ICP OES) the concentrations of Al, Ba, Be, Ca, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Na, Ni, Pb, Ti, V e Zn were determined after digestion procedure following US EPA 3051 methodology. The concentrations of metals Cd and Pb were determined by graphite furnace atomic absorption spectrometry (GFAAS) and total Hg by cold vapor atomic absorption spectrometry (CVAAS). Methodology validation according to precision and accuracy was performed by reference materials analyses for the three different analytical techniques used. Multielemental results obtained by INAA were compared to NASC (North American Shale Composite), Upper Continental Crust (UCC) and soil from Guarapiranga park values. The Enrichment Factor (EF) and Geoaccumulation Index (Igeo) were also evaluated for these data. Metal concentration results by ICP OES and AAS in the samples were compared to the TEL and PEL oriented values established by the Canadian Council of Ministers of the Environment and also adopted by CETESB (Environmental Protection Agency of the São Paulo State). The results were also compared to regional reference values (VRR) of limnic sediments from the Alto Tietê Basin. From these data an assessment of metal and trace element accumulated in the sediments from the reservoir was carried out and the possibility of these elements interfering adversely on biota and water quality of this environment.
23

Acoplamento das técnicas HPLC-ICP OES para separação e identificação de metaloproteínas em castanhas de caju / Coupling of LC-ICP OES techniques for separation and identification of metalloproteins in cashew nuts

Bruno Menezes Siqueira 02 September 2016 (has links)
O objetivo desse trabalho foi demonstrar a viabilidade do acoplamento entre as técnicas de cromatografia líquida de alta eficiência com a espectrometria de emissão óptica com plasma indutivamente acoplado (HPLC - ICP OES) em um equipamento da Thermo Fisher Scientific, visando análise de especiação elementar de espécies com maiores concentrações na amostra. A identificação de espécies moleculares associadas aos elementos Cu, Fe, Mg, e Zn em amostras de castanha de caju foi adotada como modelo para comprovar tal acoplamento. Para que o ICP OES pudesse adquirir sinais de emissão ao longo de um tempo determinado, ou seja, para que o equipamento pudesse coletar um sinal transiente, fundamental para o acoplamento HPLC - ICP OES, foi necessário executar algumas modificações. Para isso, foram feitas alterações na placa eletrônica principal do equipamento, e trocada sua caixa controladora de gases. Os parâmetros instrumentais do ICP OES foram otimizados em uma série de ensaios com o intuito de estabelecer e avaliar desempenho do instrumento e a robustez do método empregado nas análises de castanha de caju. Determinações das concentrações totais de Ca, Cu, Fe, Mg, Mn, Ni, e Zn foram feitas em amostras de castanha de caju e nos materiais de referência NIST 1515 e NIST 1547, apresentando uma exatidão do método aceitável, levando-se em consideração o preparo de amostra e a medida no ICP OES. As determinações totais elementares nas amostras de castanha de caju indicaram que os teores de Ca foram de (0,04 ± 0,01) % ; Cu (26,3 ± 5,0) mg kg-1; Fe (47,9 ± 8,8) mg kg-1; Mg (0,31 ± 0,04) %; Mn (25,6 ± 3,9) mg kg-1; Ni (24,8 ± 1,9) mg kg-1; Zn (66,3 ± 2,4) mg kg-1. Para identificação de espécies moleculares associadas aos elementos Cu, Fe, Mg, e Zn, foi feita nas amostras de castanha de caju uma extração de metais e proteínas utilizando-se de uma solução extrato de NaOH 1 mol L-1. O extrato ainda foi submetido à uma etapa de clean-up, com precipitação das proteínas com acetona e ressupenção das mesmas com tampão Tris-HCl, pH 7,4. As proteínas e metais ressupensos em tampão foram analisados no sistema HPLC ICP OES, em que a separação cromatográfica ocorreu através de uma coluna de exclusão por tamanho (SEC), a detecção molecular através do detector UV-Vis do HPLC, e a detecção elementar através do ICP OES. As espécies moleculares identificadas estão no intervalo de massa molecular compreendido entre 2 e 177 kDa, sendo que Cu, Fe e Zn apresentam associação com essas espécies moleculares. Foram monitorados ainda, no ICP OES, os sinais de intensidade de emissão de P e S. Esses elementos também apresentaram associação com espécies moleculares com peso molecular entre 2 e 177 kDa, sugerindo que essas espécies se tratam de metaloproteínas. / The aim of this study was to demonstrate the capability of coupling between liquid chromatography techniques of high efficiency with the optical emission spectrometry with inductively coupled plasma (HPLC - ICP OES) in an equipment of Thermo Fisher Scientific, aiming elemental speciation analysis of species with higher concentrations in the sample. The identification of molecular species associated with elements Cu, Fe, Mg and Zn in cashew nuts samples was adopted as a model to prove such coupling. For ICP OES could get emission signal through a certain time, so that the equipment could collect a transient signal, critical to the HPLC coupling - ICP OES, it was necessary to perform some modifications in the instrument. For this, changes were made to the main electronic board of the equipment and also changed their gas controller box. The instrumental parameters of the ICP OES were optimized in a series of tests in order to establish and evaluate performance of the instrument and the robustness of the method employed in cashew nut analysis. Determination of the total concentration of Ca, Cu, Fe, Mg, Mn, Ni and Zn were made in cashew sample and reference materials NIST 1515 and NIST in 1547, with an accuracy acceptable method, taking into account the sample preparation and measurement by ICP OES. The elemental total determinations in cashew nut samples indicated that Ca were (0.04 ± 0.01)%; Cu (26.3 ± 5.0) mg kg-1; Fe (47.9 ± 8.8) mg kg-1; Mg (0.31 ± 0.04)%; Mn (25.6 ± 3.9) mg kg-1; Ni (24.8 ± 1.9) mg kg-1; Zn (66.3 ± 2.4) mg kg-1. For the identification of molecular species associated with the elements Cu, Fe, Mg, and Zn was performed on samples of cashew nuts an extract of metals and proteins using an extract solution of NaOH 1 mol L-1. The extract was further subjected to one-step of clean-up with protein precipitation with acetone following by a resuspension with Tris-HCl buffer, pH 7.4. Proteins and metals resuspended in buffer, were analyzed in the HPLC - ICP OES system, wherein the chromatographic separation took place by a size exclusion column (SEC), the molecular detection by UV-Vis detector of HPLC, and elemental detection by ICP OES. The molecular species were identified in the molecular weight range between 2 and 177 kDa, and Cu, Fe and Zn are associated with these molecular species. Were also monitored in the ICP OES, P and S emission intensity signals. These elements also associated with molecular species having a molecular weight between 2 and 177 kDa, suggesting that this species are metalloproteins.
24

Otimização de métodos para a determinação de P, Pb e Si em gasolinas por ICP-OES / Optimization of methods for the determination of Pb, Si and P in gasolines by ICP-OES

Sandra Patricia de Andrade Mariano Santos 08 December 2017 (has links)
O objetivo deste trabalho foi desenvolver métodos para a determinação simultânea de Pb, Si e P em gasolinas por ICP OES em conformidade com a Agência Nacional de Petróleo (ANP). O mercado da gasolina no Brasil é regulado pela Agência Nacional do Petróleo (ANP) e pela Lei Federal 9.478/97 (Lei do Petróleo) e, conforme Resolução ANP n°40, de 25.10.2013, a determinação de chumbo é exigida quando houver suspeita de contaminação. O chumbo era adicionado, desde 1922 para elevar o índice antidetonante da gasolina, mas devido a sua toxicidade foi mundialmente substituído. A determinação do silício passou a ser exigida em 1 de Janeiro de 2014 nas gasolinas, porque frações leves contaminadas com silício, quando usadas como combustíveis, podem gerar problemas aos motores automotivos, uma vez que os aditivos antiespumantes, a base de oligômeros contendo silício, são adicionados durante o processo de refino. O fósforo é um aditivo estimulante da extração do petróleo, sua determinação também é exigida quando houver suspeita de contaminação, pois concentrações acima do limite máximo podem desativar os catalisadores dos carros. No preparo de amostras foram utilizadas duas estratégias, a primeira diluição da gasolina com solventes orgânicos 10% da gasolina e 90% de Premisolv-Constan, com a vantagem da int rodução direta, porém necessita câmara refrigerada e fluxo de O2. E preparo da amostra por emulsão tipo óleo/água (O/W), preparada utilizando 1 mL de gasolina com 3 mL de surfactante Tergitol TMN-6® (20% m v-1), o qual foi escolhido entre 4 surfactantes (TritonTM X-100,TritonTM X-114, TergitolTMTMN-6 e TergitolTM 15-S-9) por ter apresentado melhor desempenho na formação da emulsão e menor branco analítico. Essa segunda estratégia apresentou vantagens em relação a primeira, pois reduz a introdução da matéria orgânica para 10% e dispensa o uso de câmara especial e fluxo de O2. As amostras foram analisadas com a construção de curvas de adição padrão a fim de eliminar os efeitos de matriz. Também foram analisadas amostras dopadas com padrão orgânico nas concentrações dos limites estabelecidos pela Resolução ANP. As recuperações foram de 86% a 98% para Pb, 90% a 106% para Si e 86% a 110% para P. Portanto o método desenvolvido demonstrou a possibilidade da determinação simultânea de Si, Pb e P nos limites estabelecidos pela legislação (Pb = 5 mg LTM-1, P = 1,3 mg L-1 e Si limite máximo ainda não estabelecido) e está de acordo com a Química Verde e Gestão de Saúde Meio Ambiente e Segurança. / The objective of this work was to develop methods for the simultaneous determination of Pb, Si and P in gasoline by ICP-OES in accordance with the National Petroleum Agency (ANP). The Brazilian gasoline market is regulated by the National Petroleum Agency (ANP) and Federal Law 9.478 / 97 (Petroleum Law) and according to ANP Resolution No. 40, dated 10.25.2013, the determination of lead is required when there is suspected contamination. Lead was added since 1922 to raise the antiknock index of gasoline, but because of its toxicity it has been worldwide replaced. The determination of silicon was required on 1 January 2014 in gasoline. Light fractions contaminated with silicon, when used as fuel, can cause problems for automotive engines, since antifoaming additives, based on silicon-containing oligomers, are added during the refining process. Phosphorus is a stimulating additive to petroleum extraction; its determination is also required when contamination is suspected, as concentrations above the upper limit can deactivate the catalysts of the cars. In the preparation of samples, two strategies were used, the first dilution of gasoline with organic solvents 10% of the gasoline and 90% of Premisolv-Constan, with the advantage of direct introduction, however, requires refrigerated chamber and O2 flow. Preparation of the sample by oil / water (O / W) emulsion, using 1 ml of gasoline with 3 ml of Tergitol TMN-6 surf surfactant (20% m v-1), which was chosen among 4 surfactants (TritonTM X-100, TritonTM X-114, TergitolTM TMN-6 e TergitolTM 15-S-9), because it showed better performance in the formation of the emulsion and lower analytical blank. This second strategy presents advantages over the first one because it reduces the introduction of the organic matter to 10% and dispenses with the use of special chamber and O2 flow. Samples were analyzed by constructing standard addition curves to eliminate matrix effects. We also analyzed doped samples with organic standards in the concentrations of the limits established by ANP Resolution. The recoveries were 86% to 98% for Pb, 90% to 106% for Si and 86% to 110% for P. Therefore, the method developed demonstrated the possibility of simultaneous determination of Si, Pb and P within the limits established by the legislation (Pb = 5 mg L-1, P = 1,3 mg L-1 and Si maximum limit not yet established) and is in accordance with the Green Chemistry and Health Management Environment and Safety.
25

Avaliação da concentração de micro e macroconstituintes do sedimento do reservatório Itupararanga/Sorocaba-SP / Micro and macro sediment constituint concentration assessment of the Itupararanga reservoir/Sorocaba-SP

Sharlleny Alves Silva 28 September 2012 (has links)
O reservatório de Itupararanga foi construído pela LIGHT para gerar energia elétrica, iniciando suas operações em 1912. É formado pela barragem das águas do rio Sorocaba, o qual possui como afluentes os rios Sorocamirim, Sorocabuçu e Una. O reservatório localiza-se em uma área de fortes pressões ambientais devido à poluição difusa da produção agrícola, à carga orgânica e uso e ocupação do solo com atividades antrópicas. Desde 2003 vem recebendo alertas da CETESB, devido à presença de grande quantidade de cianobactérias que têm se mantido até os dias atuais. Em decorrência dos problemas observados nesse reservatório, o presente estudo teve por objetivo, avaliar a concentração, dos micro e macroconstituintes em amostras de perfil sedimentar de quatro pontos distintos do reservatório. Para estas análises foram utilizadas as seguintes técnicas analíticas e os respectivos elementos analisados: Análise por Ativação com Nêutrons Instrumental (INAA): As, Ba, Br, Ca, Ce, Co, Cr, Cs, Eu, Fe, Hf, K, La, Lu, Na, Nd, Rb, Sb, Sc, Sm, Ta, Tb, Th, U, Yb e Zn; Espectrometria de Emissão Ótica com Plasma Indutivamente Acoplado (ICP OES): Ag, Al, Ba, Be, Co, Cr, Cu, Fe, Li, Mg, Mn, Mo, Ni, P, Sn, Sr, Ti, V e Zn; Espectrometria de Absorção Atômica com Forno de Grafite (FG AAS) As, Cd e Pb e Analisador Direto de Mercúrio: Hg total. A validação das metodologias utilizadas foi realizada por meio das análises de materiais de referencia certificados. Os resultados obtidos foram comparados aos valores de referência NASC (North American Shale Comosite) e UCC (Upper Continental Crust). Foram calculados o fator de enriquecimento (FE) e o índice de geoacumulação (Igeo), ferramentas usadas para avaliação da presença de fontes de poluição antrópicas. As concentrações dos metais obtidos por ICP OES e FG AAS foram comparadas aos valores orientadores TEL e PEL do Conselho Canadense de Ministros do Meio Ambiente (CCME) e adotado pela CETESB. A partir desse estudo, foi possível realizar um diagnóstico da qualidade e a carga de fósforo contida nos sedimentos do reservatório, direcionando para ações corretivas que antecipem um dano maior a qualidade do reservatório. / The Itupararanga reservoir was constructed by LIGHT for generating electrical energy, starting its operations 1912. It is formed by the barrage of the waters of the Sorocaba river, formed by the rivers Sorocamirim, Sorocabuçu and Una. The reservoir finds itself in an area of strong environmental pressures due to the diffuse pollution from the agricultural production and the organic load and the use and the occupation of the soil with anthropic activities. Since 2003 it keeps receiving alerts from CETESB due to the presence of cyanobacteria that continues today. In its waters there is the presence of a toxicity which did not correlate with the results of chemical analyzes performed. Due to the problems observed in this reservoir, the present study aimed to evaluate the concentration of micro and macro constituents in samples of sedimentary profile of four different reservoir points. For these analyzes the following analytical techniques were used, with the respective elements analyzed: Analysis by Instrumental Neutron Activation (INAA): As, Ba, Br, Ca, Ce, Co, Cr, Cs, Eu, Fe, Hf, K, La, Lu, Na, Nd, Rb, Sb, Sc, Sm, Ta, Tb, Th, U, Yb and Zn; Optical Emission Spectrometry with Inductively Coupled Plasma (ICP OES): Ag, Al, Ba, Be, Co, Cr, Cu, Fe, Li, Mg, Mn, Mo, Ni, P, Sn, Sr, Ti, V and Zn; Atomic Absorption Spectrometry with Graphite Furnace (FG AAS) As, Cd and Pb and Direct Mercury Analyzer: total Hg. The validation of used methodologies was performed by the analysis of certified reference materials. The results obtained were compared to reference values NASC (North American Shale Comosite), UCC (Upper Continental Crust). The enrichment factors (EF) and the geoaccumulation index (Igeo), were calculated; they are tools used to evaluate the presence of anthropic pollution sources. The metal concentrations obtained by ICP OES and FG AAS were compared to the guiding values TEL and PEL from the Canadian Council of Ministers of the Environment (CCME) and adopted by CETESB. From this study, it was possible to make a diagnosis of the quality and load of phosphorus in the reservoir sediments, directing to corrective actions that prevent greater harm to the quality of the reservoir.
26

Laser induced breakdown spectroscopy (LIBS) applied to the quantification of elements in fertilizers / Laser Induced Breakdown Spectroscopy (LIBS) applied to the quantification of elements in fertilizer

Cesar Cervantes 16 February 2017 (has links)
A capacidade do instrumento Laser Induced Breakdown Spectroscopy (LIBS) foi investigada para a possibilidade de atuar como uma ferramenta de quantificação. Um instrumento de baixo custo fechado do dispositivo de acoplamento de cargas (CCD) foi utilizado a fim de quantificar (K), (Ca), (Mn), (Mg), e (Cu) presente em 26 amostras de fertilizantes constituídos de diferentes matrizes, alguns fosfato de organo-mineral e outros de material inorgânico (quantificação de elementos presentes em fertilizante organominerais nunca tinha acontecido). Duas técnicas de referências foram utilizadas para validar as habilidades de quantificação: Plasma Acoplado Indutivo-Espectroscopia de Emissão Ótica (ICP-OES) e Espectroscopia de Absorção Atômica (AAS). O melhor pico representando cada elemento foi encontrado para produzir a melhor correlação entre cada pixel CCD e a concentração de elementos obtidos a partir das técnicas de referência. O pico mais adequado de LIBS foi tratado com um procedimento de normalização, a fim de corrigir os efeitos de matriz e as pequenas flutuações no plasma. Após o pico produzido por LIBS ser normalizado, foi linearmente montado contra os dados das duas técnicas de referência e duas curvas de calibração para cada um dos elementos foram construídas. Quando o procedimento de normalização não foi aplicado, valores de R-quadrado diminuiu entre 0,1-0,2 em quase todos os elementos. No entanto, entre os resultados produzidos pelas duas curvas de calibração, após o procedimento de normalização ser aplicado, os valores de correlação R-quadrado variaram de 0,8-0,98, o que foi considerado adequado para os elementos de interesse. O LOD para LIBS também foi calculado e verificou-se que quando os valores estavam abaixo do limite de determinação, a validade de LIBS como uma ferramenta de quantificação diminuiu. Além disso, uma análise de erro de validação cruzada foi feita com LIBS-ICP e LIBS-AAS, o que originou valores de erro de 22% - 28% para alguns dos elementos, quando todas as amostras foram incluídas. Mas quando as amostras abaixo do LOD foram excluídas, aqueles valores de erro desceram significativamente, e resultou na gama de 7% - 20%. Uma análise de validação cruzada também foi feita para as concentrações dos elementos determinados pelas técnicas de referência e esses resultados produziram valores de erro variando de 9% - 23%. As semelhanças entre os valores de erro LIBS e os valores de erro das técnicas de referência, dá credibilidade para a capacidade de LIBS para atuar como uma ferramenta para a quantificação de elementos presentes em fertilizantes compostos de diferentes matrizes. / The ability of the instrument Laser Induced Breakdown Spectroscopy (LIBS) was investigated for the possibility of acting as a quantification tool of analysis. A low-cost gated charged coupled device (CCD) was used in order to quantify (K), (Ca), (Mn), (Mg), and (Cu) present in 26 fertilizer samples made up of different matrixes, some of organic-mineral phosphate and others of inorganic material; evaluation of elements in organomineral fertilizers had never been done by LIBS. Two reference techniques were used in order to validate the quantification abilities: Inductive Coupled Plasma-Optical Emission Spectroscopy (ICP-OES) and Atomic Absorption Spectroscopy (AAS). The best peak representing each element was found by finding the best correlation between each CCD pixel and the element concentration obtained from the reference techniques. The most appropriate peak from LIBS was treated with a normalization procedure in order to correct for physical matrix effects and small plasma fluctuations. After the LIBS peak was normalized, it was linearly fitted against the data from the two reference techniques, thus two calibration curves for each element were built. When the normalization procedure was not applied, R-squared values decreased between 0.1 - 0.2 in almost all the elements. However, amongst the results of the two calibration curves after the normalization procedure was applied, R-squared correlation values ranged from 0.8-0.98, which were considered adequate for the elements of interest. The LOD for LIBS was also calculated and it was found that when values were below the LOD, the validity of LIBS as a quantification tool decreased. Moreover, a cross-validation error analysis was done with LIBS-ICP and LIBS-AAS, which yielded error values of 22% - 28% for some of the elements when all samples were included, but when samples below the LOD were excluded, those error values went down significantly, and resulted within the range of 7% - 20%. A cross-validation analysis was also done for the element concentrations determined by the reference techniques and those results yielded error values ranging from 9%- 23%. The similarities between the LIBS error values and the reference techniques error values, gives credibility to the ability of LIBS to act as a tool for quantifying elements in fertilizers composed of different matrixes.
27

Avaliação da concentração de metais e outros elementos de interesse em amostras de sedimentos dos estuários de Santos/São Vicente e Cananéia, Estado de São Paulo, Brasil / Metal and trace element sediment assessment from two estuarine systems: Santos/São Vicente and Cananéia, State of São Paulo, Brazil

Amorim, Eduardo Paulo de 10 October 2012 (has links)
No presente trabalho foram avaliados os teores de alguns metais tóxicos como Cd, Hg e Pb, outros elementos maiores e traço em amostras de sedimentos superficiais, provenientes de dois sistemas sob diferentes graus de ação antrópica, o sistema estuarino de Santos/São Vicente e na porção sul do sistema estuarino lagunar de Cananéia, ambos no litoral do Estado de São Paulo. Foram coletados sedimentos em 16 estações no estuário de Santos/São Vicente e 13 estações no estuário de Cananéia, durante o verão e inverno de 2005 e 2006, em ambos os estuários. Foram utilizadas 3 técnicas analíticas: NAA, AAS e ICP OES. Pela técnica de ativação neutrônica (NAA) foram determinados os teores dos elementos maiores (Ca, Fe e Na), elementos traço (As, Ba, Br, Cd, Co, Cu, Cr, Cs, Hf, Rb, Sb, Sc, Ta, Th, U, Zn e terras raras La, Ce, Eu, Nd, Sm, Lu, Tb, Yb). Pela técnica de espectrometria de emissão ótica com plasma indutivamente acoplado (ICP OES), foram avaliados os teores de Al, Ba, Be, Bi, Co, Cu, Cr, Fe, Li, Mn, Mo, Ni, Sr e Zn. Pela técnica de espectrometria de absorção atômica atômica (AAS), foram determinados por forno de grafite (GF AAS) Cd e Pb, e pela técnica de geração de vapor frio (CV AAS), o Hg. As metodologias analíticas foram validadas quanto à precisão e exatidão, por meio da análise de materiais de referência certificados. Foram calculados os limites de detecção e quantificação, para cada elemento analisado, para as diferentes técnicas analíticas. Foram avaliadas também as variações espaciais, sazonais (inverno e verão) e temporais (2005 e 2006) dos metais e elementos traço nos sedimentos. No estuário de Santos/São Vicente, em geral, as concentrações de metais e elementos traço, teores de matéria orgânica e % da fração pelítica encontrados no canal de Santos (área 1), foram maiores do que na baía de Santos (área 2) e no canal de São Vicente (área 3). A área 1 sofre grande impacto das atividades industriais da região de Cubatão e do porto de Santos. Os sedimentos da estação 14 (área 3, Canal de São Vicente) apresentaram comportamento semelhante aos da área 1, sofrendo influência do polo industrial e por estar localizado em uma área de mangue. Na comparação com os valores orientadores TEL e PEL adotados pela CETESB para os metais tóxicos em sedimentos, verificou-se que a área 1 ultrapassou os limites TEL para alguns dos metais, principalmente para Hg. Os sedimentos da área 2 e da área 3 (exceto estação 14), não ultrapassaram os valores limites para a maioria dos metais analisados. Apesar dos sedimentos do estuário de Cananéia serem compostos principalmente por frações de areia, em algumas estações a fração pelítica foi bastante significativa. A partir dos resultados obtidos na região de Cananéia, observou-se que as concentrações potencialmente disponíveis dos metais Cd, Pb, Hg, Cr, Cu, Ni e Zn se encontraram abaixo dos limites estabelecidos pela legislação CONAMA 344/2004 para sedimentos e dos limites TEL e PEL, para as 3 áreas avaliadas: área 1 (Mar de Cananéia), área 2 (Baia de Trapandé) e área 3 (Mar de Cubatão). Fator de Enriquecimento (FE) e índice de geoacumulação (Igeo), ferramentas geoquímicas para avaliação da contaminação de metais e elementos traço, foram usadas para avaliar os níveis de contaminação em ambos os estuários. Aos resultados obtidos foi aplicada análise estatística multivariada e por último, os resultados foram comparados com outros dados publicados na literatura para as regiões em estudo (Santos/São Vicente e Cananéia). / This study evaluated some toxic metals such as Cd, Hg and Pb and some other major and trace elements in surface sediment samples, from two different systems under different degrees of anthropogenic actions: the estuarine system of Santos/São Vicente and the southern part of the Cananéia estuary, both on the São Paulo state coast. Sediment samples were collected in 16 stations in the Santos/São Vicente estuary and 13 stations in the Cananéia estuary, during summer and winter of 2005 and 2006, in both estuaries. Three analytical techniques were used: NAA, AAS and ICP OES. NAA was used for the quantification of major element concentration levels (Ca, Fe and Na), trace elements (As, Ba, Br, Cd, Co, Cu, Cr, Cs, Hf, Rb, Sb, Sc, Se, Ta, Th, U, and Zn and rare earths elements La, Ce, Eu, Nd, Sm, Lu, Tb, Yb). ICP OES was used for determination of the concentration levels of Al, Ba, Be, Bi, B, Cd, Co, Pb, Cu, Cr, Sn, Sr, Fe, Li, Mn, Mo, Ni, Tl, Ti, V and Zn. AAS for Cd and Pb quantification through graphite furnace (GF AAS) and Hg through cold vapor generation (CV AAS). Methodology validation according to precision and accuracy was performed by reference material analyses for the three analytical techniques used. Detection and quantification limits were calculated for each element evaluated. Seasonal variations (summer and winter), spatial and temporal (2005 e 2006) variations of metals and trace elements were also evaluated. In the Santos estuary, in general, metal and trace element concentrations , organic matter content and % of pellitic fraction found in the Santos channel (area 1) were higher than those of the Santos Bay (area 2) and São Vicente channel (area 3). Area 1 suffers high impact from industrial activities from the Cubatão region and Santos port. The sediments from station 14 (area 3, São Vicente channel), showed the same behavior of those from area 1, suffering influence from the industrial pole and located in a mangrove area. In comparison with TEL and PEL oriented values adopted by CETESB for toxic metals content in sediments, area 1 surpassed the TEL limits for some metals, mainly for Hg. Sediments from area 2 and 3 (except station 14), did not exceed the limits for most of the metals analyzed. Although the sediments from Cananéia region were composed mainly of sandy fractions, in some stations the pellitic fraction was greatly significant. From the results obtained in the region, the concentration levels of metals potentially available such as Cd, Cr, Cu, Hg, Ni, Pb and Zn were below the limits TEL and PEL oriented values and CONAMA 344/2004 resolution for the 3 areas assessed: area 1 (Cananéia sea), area 2 (Trapandé Bay) and area 3 (Cubatão sea). Enrichment Factor (EF) and Geoaccumulation index (Igeo), geochemical tools used for contamination assessment were used to evaluate the contamination level in both estuaries. Multivariate statistical analysis was applied to the results which were then compared to the results of other published studies in these regions (Santos/São Vicente and Cananéia).
28

Avaliação da concentração de micro e macroconstituintes do sedimento do reservatório Itupararanga/Sorocaba-SP / Micro and macro sediment constituint concentration assessment of the Itupararanga reservoir/Sorocaba-SP

Silva, Sharlleny Alves 28 September 2012 (has links)
O reservatório de Itupararanga foi construído pela LIGHT para gerar energia elétrica, iniciando suas operações em 1912. É formado pela barragem das águas do rio Sorocaba, o qual possui como afluentes os rios Sorocamirim, Sorocabuçu e Una. O reservatório localiza-se em uma área de fortes pressões ambientais devido à poluição difusa da produção agrícola, à carga orgânica e uso e ocupação do solo com atividades antrópicas. Desde 2003 vem recebendo alertas da CETESB, devido à presença de grande quantidade de cianobactérias que têm se mantido até os dias atuais. Em decorrência dos problemas observados nesse reservatório, o presente estudo teve por objetivo, avaliar a concentração, dos micro e macroconstituintes em amostras de perfil sedimentar de quatro pontos distintos do reservatório. Para estas análises foram utilizadas as seguintes técnicas analíticas e os respectivos elementos analisados: Análise por Ativação com Nêutrons Instrumental (INAA): As, Ba, Br, Ca, Ce, Co, Cr, Cs, Eu, Fe, Hf, K, La, Lu, Na, Nd, Rb, Sb, Sc, Sm, Ta, Tb, Th, U, Yb e Zn; Espectrometria de Emissão Ótica com Plasma Indutivamente Acoplado (ICP OES): Ag, Al, Ba, Be, Co, Cr, Cu, Fe, Li, Mg, Mn, Mo, Ni, P, Sn, Sr, Ti, V e Zn; Espectrometria de Absorção Atômica com Forno de Grafite (FG AAS) As, Cd e Pb e Analisador Direto de Mercúrio: Hg total. A validação das metodologias utilizadas foi realizada por meio das análises de materiais de referencia certificados. Os resultados obtidos foram comparados aos valores de referência NASC (North American Shale Comosite) e UCC (Upper Continental Crust). Foram calculados o fator de enriquecimento (FE) e o índice de geoacumulação (Igeo), ferramentas usadas para avaliação da presença de fontes de poluição antrópicas. As concentrações dos metais obtidos por ICP OES e FG AAS foram comparadas aos valores orientadores TEL e PEL do Conselho Canadense de Ministros do Meio Ambiente (CCME) e adotado pela CETESB. A partir desse estudo, foi possível realizar um diagnóstico da qualidade e a carga de fósforo contida nos sedimentos do reservatório, direcionando para ações corretivas que antecipem um dano maior a qualidade do reservatório. / The Itupararanga reservoir was constructed by LIGHT for generating electrical energy, starting its operations 1912. It is formed by the barrage of the waters of the Sorocaba river, formed by the rivers Sorocamirim, Sorocabuçu and Una. The reservoir finds itself in an area of strong environmental pressures due to the diffuse pollution from the agricultural production and the organic load and the use and the occupation of the soil with anthropic activities. Since 2003 it keeps receiving alerts from CETESB due to the presence of cyanobacteria that continues today. In its waters there is the presence of a toxicity which did not correlate with the results of chemical analyzes performed. Due to the problems observed in this reservoir, the present study aimed to evaluate the concentration of micro and macro constituents in samples of sedimentary profile of four different reservoir points. For these analyzes the following analytical techniques were used, with the respective elements analyzed: Analysis by Instrumental Neutron Activation (INAA): As, Ba, Br, Ca, Ce, Co, Cr, Cs, Eu, Fe, Hf, K, La, Lu, Na, Nd, Rb, Sb, Sc, Sm, Ta, Tb, Th, U, Yb and Zn; Optical Emission Spectrometry with Inductively Coupled Plasma (ICP OES): Ag, Al, Ba, Be, Co, Cr, Cu, Fe, Li, Mg, Mn, Mo, Ni, P, Sn, Sr, Ti, V and Zn; Atomic Absorption Spectrometry with Graphite Furnace (FG AAS) As, Cd and Pb and Direct Mercury Analyzer: total Hg. The validation of used methodologies was performed by the analysis of certified reference materials. The results obtained were compared to reference values NASC (North American Shale Comosite), UCC (Upper Continental Crust). The enrichment factors (EF) and the geoaccumulation index (Igeo), were calculated; they are tools used to evaluate the presence of anthropic pollution sources. The metal concentrations obtained by ICP OES and FG AAS were compared to the guiding values TEL and PEL from the Canadian Council of Ministers of the Environment (CCME) and adopted by CETESB. From this study, it was possible to make a diagnosis of the quality and load of phosphorus in the reservoir sediments, directing to corrective actions that prevent greater harm to the quality of the reservoir.
29

[pt] DESENVOLVIMENTO DE MÉTODO PARA DETERMINAÇÃO MULTIELEMENTAR EM BIODIESEL POR ICP-MS / [en] DEVELOPMENT OF A METHOD FOR MULTIELEMENTAL DETERMINATION IN BIODIESEL BY ICP-MS

EIDER FERNANDO ALVES DOS SANTOS 27 December 2011 (has links)
[pt] Os elementos de maior interesse no biodiesel são os resíduos de catálise do processo produtivo (Na e K), os delimitados por legislação ambiental vigente (S, por exemplo) e os elementos venenosos aos catalisadores automotivos (Pb, V, P e Hg); porém, pesquisas orientadas no sentido de produzir metodologias analíticas para a realização de determinações em biodiesel vêm buscando um mapeamento elementar mais completo do combustível. Técnicas como ICP OES, ICP-MS com célula de reação/colisão, FAAS, GFAAS têm sido usualmente empregadas em determinações diretas ou não, mas ainda existem combinações de preparo de amostra e técnica analítica a ser pesquisadas. O presente trabalho teve como objetivo a avaliação de um sistema de decomposição ácida de amostra de biodiesel, visando à decomposição ácida da maior quantidade possível de matéria orgânica presente na matriz e a consequente determinação em ICP-MS. O processo de decomposição ácida, avaliado pela concentração de carbono residual, determinado em ICP OES, não requer grandes quantidades nem de energia térmica e nem do agente oxidante e ainda permite, após processo de redução da matriz nítrica remanescente, uma determinação direta em ICP-MS utilizando padrões aquosos na confecção das curvas e sem a necessidade de célula de colisão/reação. Foram determinados Ag, Ba, Cu, Mn, Mo, Ni, Ti e Zn em amostras de biodiesel de 4 matérias-primas diferentes e em duas amostras certificadas de biodiesel (NIST) e, tanto os resultados de recuperação, que variaram entre 90 e 110 por cento, quanto o comparativo realizado com as metodologias por ICP OES, validaram os resultados. / [en] Biodiesel appeared in this scenario as an alternative short-term, compatible with the current technologies and without the necessity of major modifications. The elements of greatest interest are the residue of catalyst of the production process (Na, K), those limited by environmental regulations (S) and those that act like poisons for the catalyst system of vehicles (Pb, V, P and Hg), but researches aimed to produce analytical methodologies for determinations in Biodiesel, have sought to achieve a multielement mapping of the fuel (Woods ET AL, 2007). Techniques like ICP OES, ICP-MS with reaction cell, FAAS, GFAAS have been usually used in direct or indirect determinations, but still there are combinations of sample preparation and analytical techniques to be studied. This present work sought to evaluate an analyzing system in ICP-MS after a digestion procedure looking for the minimal quantity of organic matter at the final sample. The preliminary results showed that the digestion process, evaluated by the concentration of residual carbon determined by ICP OES, it can be fast and does not require large amounts of energy and oxidizing agent. And still allow, after reducing the nitric matrix, the use of aqueous standards at the calibration curve. It was monitored Ag, Ba, Cu, Mn, Mo, Ni, Ti and Zn in 4 different sources of raw material for biodiesel, and the method was validated by the analysis of two NIST standards by the comparison with ICP OES results and by the recover results ranged between 90 and 110 per cent.
30

Determinação multielementar de elementos traços em radiofármacos produzidos na Diretoria de Radiofarmácia por espectrometria de emissão por plasma / Multielemental determination of trace elements in radiopharmaceuticals produced at the radiopharmacy center using icp-oes technique

Angélica Tamião Tavares 29 November 2013 (has links)
Os radiofármacos são preparações farmacêuticas, que contém radionuclídeo, utilizados em medicina nuclear. O objetivo desse trabalho foi estudar as concentrações de elementos químicos, principalmente metais, em amostras de radiofármacos ALBUMINA-TEC, DEX 70-TEC, DEX 500-TEC, DISIDATEC, DMSA-TEC, EC-TEC, DTPA-TEC, FITATO-TEC, GHA-TEC, MDP-TEC, MIBI-TEC, PIRO-TEC, FDG-Flúor-18, GERADOR IPEN-TEC, IODO-131 SOLUÇÃO. As análises foram realizadas em equipamento Vista MPX simultâneo ICP-OES (Agilent, Australia). A validação do método foi realizado segundo os critérios descritos na RDC n° 899: Guia para validação de métodos analíticos e bioanalíticos de 29 de maio de 2003. De acordo com a Farmacopeia Americana (USP), as impurezas elementares com potencial toxicidade devem ser quantificados. Uma proposta de revisão USP 35 introduz a técnica de espectrometria de emissão atômica para a análise de elementos. Os resultados de validação das análises no ICP-OES indicam a necesidade de controle da limpeza e manutenção do equipamento, alterações do sample uptake delay e avaliação da robustez com as linhas do Mg. As curvas analíticas e faixas de concentracões analisadas foram lineares com r > 0,99. Os resultados de DPR foram abaixo de 5%. Todos os resultados dos parâmetros avaliados estão de acordo com os estabelecidos pela ANVISA. / Radiopharmaceuticals are pharmaceutical preparations containing radionuclide used in nuclear medicine. The aim of this work was to study the concentrations of chemical elements, especially metals, in samples of radiopharmaceuticals ALBUMINA-TEC, DEX 70-TEC, DEX 500-TEC, DISIDA-TEC, DMSA-TEC, EC-TEC, DTPA-TEC, FITATO-TEC, GHA-TEC, MDP-TEC, MIBI-TEC, PIRO-TEC, FDG-FLÚOR-18, GERADOR IPEN-TEC, IODO-131 SOLUÇÃO. The analyses were carried out simultaneously in an ICP-OES Vista MPX (Agilent). The method validation was performed according to the criteria defined in RDC No. 899 : Guide for validation of analytical and bioanalytical methods for May 29, 2003 of the ANVISA. According to the U.S. Pharmacopeia (USP), the elemental impurities with potential toxicity must be quantified. A proposed revision to USP 35 introduces the technique of atomic emission spectrometry for the analysis of elements. The validation results of the ICP- OES analyzes indicated the necessary to control the cleaning and maintenance of equipment, changes in sample uptake delay and robustness evaluation with the lines of Mg. The analytical curves and concentration ranges analyzed were linear with r > 0.99. The results of DPR were below 5%. All the parameters were below the established by ANVISA .

Page generated in 0.0656 seconds