• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • 10
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 44
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo sobre a determinação de antimônio em amostras ambientais pelo método de análise por ativação com nêutrons. validação da metodologia e determinação da incerteza da medição / A study on antimony determination in environmental samples by neutron activation analysis. validation of the methodology and determination of the uncertainty of the measurement

Matsubara, Tassiane Cristina Martins 09 September 2011 (has links)
O antimônio é um elemento encontrado em baixas concentrações no meio ambiente. No entanto, a sua determinação tem despertado grande interesse devido ao conhecimento de sua toxicidade e da crescente aplicação na indústria. A determinação de antimônio tem sido um desafio para os pesquisadores uma vez que o elemento é encontrado em baixas concentrações, o que faz de sua análise uma tarefa difícil. Portanto, embora a análise por ativação de nêutrons (NAA) seja um método adequado para a determinação de vários elementos em diferentes tipos de matriz, no caso de Sb, a análise apresenta algumas dificuldades. A principal dificuldade é devido às interferências espectrais. O objetivo desta pesquisa foi validar o método de NAA para a determinação de Sb em amostras ambientais. Para estabelecer condições adequadas para a determinação de Sb, ensaios preliminares foram realizados para posterior análise de materiais de referência certificados (MRC). O procedimento experimental consistiu em irradiar amostras juntamente com padrão sintético de Sb por períodos de 8 ou 16 horas no reator nuclear de pesquisa IEA-R1, seguido de espectrometria de raios gama. A quantificação de Sb foi realizada pela medição dos radioisótopos de 122Sb e 124Sb. Ensaios preliminares indicaram a presença de Sb em papel de filtro Whatman, utilizado no preparo do padrão, porém em teor muito baixo, podendo ser considerado desprezível. No caso do material plástico utilizado como invólucro para a irradiação da amostra, foi verificado que ele deve ser escolhido cuidadosamente, pois dependendo do plástico, este pode conter Sb. A análise da estabilidade da solução padrão diluída de Sb, dentro do período de oito meses, mostrou que não há alteração significativa na concentração deste elemento. Os resultados obtidos nas análises dos materiais de referência certificados indicaram a formação de radioisótopos de 76As e também de 134Cs e 152Eu, podendo interferir na determinação de Sb pela medição de 122Sb, devido à proximidade de energias dos raios gama emitidos. Além disso, a alta atividade do 24Na pode mascarar o pico do 122Sb e dificultar a sua detecção. As análises dos MRC indicaram que a exatidão e a precisão dos resultados de Sb dependem principalmente do tipo e composição da matriz, da sua concentração na amostra, do radioisotopo medido e do tempo de decaimento utilizado para a medição. A avaliação dos componentes que contribuem para a medição da incerteza da concentração de Sb, mostrou que a maior contribuição da incerteza é dada pela estatística de contagem da amostra. Os resultados da avaliação da incerteza indicaram também que o valor da incerteza padrão combinada depende do radioisótopo medido e do tempo de decaimento utilizado para as contagens. Este estudo mostrou que a NAA é um método bastante adequado na determinação de Sb em amostras ambientais, possibilitando a obtenção de resultados com baixos valores de incerteza e por ser uma técnica puramente instrumental, permite a análise de um grande número de amostras. / Antimony is an element found in low concentrations in the environment. However, its determination has attracted great interest due to the knowledge of its toxicity and increasing application in industry. The determination of antimony has been a challenge for researchers since this element is found in low concentrations which make its analysis a difficult task. Therefore, although neutron activation analysis (NAA) is an appropriate method for the determination of various elements in different types of matrix, in the case of Sb its analysis presents some difficulties, mainly due to spectral interferences. The objective of this research was to validate the NAA method for Sb determination in environmental samples. To establish appropriate conditions for Sb determinations, preliminary assays were carried out for further analysis of certified reference materials (CRM). The experimental procedure was to irradiate samples with a synthetic Sb standard for a period of 8 or 16 hours in the IEA-R1 nuclear research reactor, followed by gamma ray spectrometry. The quantification of Sb was performed by measuring the radioactive isotopes of 122Sb and 124Sb. The results of preliminary assays indicated the presence of Sb in Whatman no 40 filter paper used in the preparation of the synthetic standard, but at very low concentrations, which could be considered negligible. In the case of the plastic material used in bags for the sample irradiation, it should be chosen carefully, because depending on the thickness, they may contain Sb. The analyses of the stability of the diluted Sb standard solution showed no change in the Sb concentration within eight months after its preparation. Results obtained in the analysis of certified reference materials indicated the interference of 76As and also of 134Cs and 152Eu in the Sb determinations by measuring 122Sb, due to the proximity of the gamma ray energies. The high activity of 24Na can also mask the peak of 122Sb hindering its detection. The analysis of CRM indicated that the accuracy and precision of the results depend on the type of matrix analyzed, its concentration in the sample, radioisotope measured and of the decay time used for the measurements. The analysis of the components that contribute to the uncertainty of the Sb concentration indicated that the largest uncertainty contribution is given by statistical counting of the sample. The findings also showed that the value of combined standard uncertainty depends on the radioisotopes of Sb measured and the decay time used for counting. This study showed that NAA is a very adequate method for Sb determinations in environmental samples furnishing results with low uncertainty values.
2

Estudo sobre a determinação de antimônio em amostras ambientais pelo método de análise por ativação com nêutrons. validação da metodologia e determinação da incerteza da medição / A study on antimony determination in environmental samples by neutron activation analysis. validation of the methodology and determination of the uncertainty of the measurement

Tassiane Cristina Martins Matsubara 09 September 2011 (has links)
O antimônio é um elemento encontrado em baixas concentrações no meio ambiente. No entanto, a sua determinação tem despertado grande interesse devido ao conhecimento de sua toxicidade e da crescente aplicação na indústria. A determinação de antimônio tem sido um desafio para os pesquisadores uma vez que o elemento é encontrado em baixas concentrações, o que faz de sua análise uma tarefa difícil. Portanto, embora a análise por ativação de nêutrons (NAA) seja um método adequado para a determinação de vários elementos em diferentes tipos de matriz, no caso de Sb, a análise apresenta algumas dificuldades. A principal dificuldade é devido às interferências espectrais. O objetivo desta pesquisa foi validar o método de NAA para a determinação de Sb em amostras ambientais. Para estabelecer condições adequadas para a determinação de Sb, ensaios preliminares foram realizados para posterior análise de materiais de referência certificados (MRC). O procedimento experimental consistiu em irradiar amostras juntamente com padrão sintético de Sb por períodos de 8 ou 16 horas no reator nuclear de pesquisa IEA-R1, seguido de espectrometria de raios gama. A quantificação de Sb foi realizada pela medição dos radioisótopos de 122Sb e 124Sb. Ensaios preliminares indicaram a presença de Sb em papel de filtro Whatman, utilizado no preparo do padrão, porém em teor muito baixo, podendo ser considerado desprezível. No caso do material plástico utilizado como invólucro para a irradiação da amostra, foi verificado que ele deve ser escolhido cuidadosamente, pois dependendo do plástico, este pode conter Sb. A análise da estabilidade da solução padrão diluída de Sb, dentro do período de oito meses, mostrou que não há alteração significativa na concentração deste elemento. Os resultados obtidos nas análises dos materiais de referência certificados indicaram a formação de radioisótopos de 76As e também de 134Cs e 152Eu, podendo interferir na determinação de Sb pela medição de 122Sb, devido à proximidade de energias dos raios gama emitidos. Além disso, a alta atividade do 24Na pode mascarar o pico do 122Sb e dificultar a sua detecção. As análises dos MRC indicaram que a exatidão e a precisão dos resultados de Sb dependem principalmente do tipo e composição da matriz, da sua concentração na amostra, do radioisotopo medido e do tempo de decaimento utilizado para a medição. A avaliação dos componentes que contribuem para a medição da incerteza da concentração de Sb, mostrou que a maior contribuição da incerteza é dada pela estatística de contagem da amostra. Os resultados da avaliação da incerteza indicaram também que o valor da incerteza padrão combinada depende do radioisótopo medido e do tempo de decaimento utilizado para as contagens. Este estudo mostrou que a NAA é um método bastante adequado na determinação de Sb em amostras ambientais, possibilitando a obtenção de resultados com baixos valores de incerteza e por ser uma técnica puramente instrumental, permite a análise de um grande número de amostras. / Antimony is an element found in low concentrations in the environment. However, its determination has attracted great interest due to the knowledge of its toxicity and increasing application in industry. The determination of antimony has been a challenge for researchers since this element is found in low concentrations which make its analysis a difficult task. Therefore, although neutron activation analysis (NAA) is an appropriate method for the determination of various elements in different types of matrix, in the case of Sb its analysis presents some difficulties, mainly due to spectral interferences. The objective of this research was to validate the NAA method for Sb determination in environmental samples. To establish appropriate conditions for Sb determinations, preliminary assays were carried out for further analysis of certified reference materials (CRM). The experimental procedure was to irradiate samples with a synthetic Sb standard for a period of 8 or 16 hours in the IEA-R1 nuclear research reactor, followed by gamma ray spectrometry. The quantification of Sb was performed by measuring the radioactive isotopes of 122Sb and 124Sb. The results of preliminary assays indicated the presence of Sb in Whatman no 40 filter paper used in the preparation of the synthetic standard, but at very low concentrations, which could be considered negligible. In the case of the plastic material used in bags for the sample irradiation, it should be chosen carefully, because depending on the thickness, they may contain Sb. The analyses of the stability of the diluted Sb standard solution showed no change in the Sb concentration within eight months after its preparation. Results obtained in the analysis of certified reference materials indicated the interference of 76As and also of 134Cs and 152Eu in the Sb determinations by measuring 122Sb, due to the proximity of the gamma ray energies. The high activity of 24Na can also mask the peak of 122Sb hindering its detection. The analysis of CRM indicated that the accuracy and precision of the results depend on the type of matrix analyzed, its concentration in the sample, radioisotope measured and of the decay time used for the measurements. The analysis of the components that contribute to the uncertainty of the Sb concentration indicated that the largest uncertainty contribution is given by statistical counting of the sample. The findings also showed that the value of combined standard uncertainty depends on the radioisotopes of Sb measured and the decay time used for counting. This study showed that NAA is a very adequate method for Sb determinations in environmental samples furnishing results with low uncertainty values.
3

Avaliação da concentração de metais e outros elementos de interesse em amostras de sedimentos dos estuários de Santos/São Vicente e Cananéia, Estado de São Paulo, Brasil / Metal and trace element sediment assessment from two estuarine systems: Santos/São Vicente and Cananéia, State of São Paulo, Brazil

Eduardo Paulo de Amorim 10 October 2012 (has links)
No presente trabalho foram avaliados os teores de alguns metais tóxicos como Cd, Hg e Pb, outros elementos maiores e traço em amostras de sedimentos superficiais, provenientes de dois sistemas sob diferentes graus de ação antrópica, o sistema estuarino de Santos/São Vicente e na porção sul do sistema estuarino lagunar de Cananéia, ambos no litoral do Estado de São Paulo. Foram coletados sedimentos em 16 estações no estuário de Santos/São Vicente e 13 estações no estuário de Cananéia, durante o verão e inverno de 2005 e 2006, em ambos os estuários. Foram utilizadas 3 técnicas analíticas: NAA, AAS e ICP OES. Pela técnica de ativação neutrônica (NAA) foram determinados os teores dos elementos maiores (Ca, Fe e Na), elementos traço (As, Ba, Br, Cd, Co, Cu, Cr, Cs, Hf, Rb, Sb, Sc, Ta, Th, U, Zn e terras raras La, Ce, Eu, Nd, Sm, Lu, Tb, Yb). Pela técnica de espectrometria de emissão ótica com plasma indutivamente acoplado (ICP OES), foram avaliados os teores de Al, Ba, Be, Bi, Co, Cu, Cr, Fe, Li, Mn, Mo, Ni, Sr e Zn. Pela técnica de espectrometria de absorção atômica atômica (AAS), foram determinados por forno de grafite (GF AAS) Cd e Pb, e pela técnica de geração de vapor frio (CV AAS), o Hg. As metodologias analíticas foram validadas quanto à precisão e exatidão, por meio da análise de materiais de referência certificados. Foram calculados os limites de detecção e quantificação, para cada elemento analisado, para as diferentes técnicas analíticas. Foram avaliadas também as variações espaciais, sazonais (inverno e verão) e temporais (2005 e 2006) dos metais e elementos traço nos sedimentos. No estuário de Santos/São Vicente, em geral, as concentrações de metais e elementos traço, teores de matéria orgânica e % da fração pelítica encontrados no canal de Santos (área 1), foram maiores do que na baía de Santos (área 2) e no canal de São Vicente (área 3). A área 1 sofre grande impacto das atividades industriais da região de Cubatão e do porto de Santos. Os sedimentos da estação 14 (área 3, Canal de São Vicente) apresentaram comportamento semelhante aos da área 1, sofrendo influência do polo industrial e por estar localizado em uma área de mangue. Na comparação com os valores orientadores TEL e PEL adotados pela CETESB para os metais tóxicos em sedimentos, verificou-se que a área 1 ultrapassou os limites TEL para alguns dos metais, principalmente para Hg. Os sedimentos da área 2 e da área 3 (exceto estação 14), não ultrapassaram os valores limites para a maioria dos metais analisados. Apesar dos sedimentos do estuário de Cananéia serem compostos principalmente por frações de areia, em algumas estações a fração pelítica foi bastante significativa. A partir dos resultados obtidos na região de Cananéia, observou-se que as concentrações potencialmente disponíveis dos metais Cd, Pb, Hg, Cr, Cu, Ni e Zn se encontraram abaixo dos limites estabelecidos pela legislação CONAMA 344/2004 para sedimentos e dos limites TEL e PEL, para as 3 áreas avaliadas: área 1 (Mar de Cananéia), área 2 (Baia de Trapandé) e área 3 (Mar de Cubatão). Fator de Enriquecimento (FE) e índice de geoacumulação (Igeo), ferramentas geoquímicas para avaliação da contaminação de metais e elementos traço, foram usadas para avaliar os níveis de contaminação em ambos os estuários. Aos resultados obtidos foi aplicada análise estatística multivariada e por último, os resultados foram comparados com outros dados publicados na literatura para as regiões em estudo (Santos/São Vicente e Cananéia). / This study evaluated some toxic metals such as Cd, Hg and Pb and some other major and trace elements in surface sediment samples, from two different systems under different degrees of anthropogenic actions: the estuarine system of Santos/São Vicente and the southern part of the Cananéia estuary, both on the São Paulo state coast. Sediment samples were collected in 16 stations in the Santos/São Vicente estuary and 13 stations in the Cananéia estuary, during summer and winter of 2005 and 2006, in both estuaries. Three analytical techniques were used: NAA, AAS and ICP OES. NAA was used for the quantification of major element concentration levels (Ca, Fe and Na), trace elements (As, Ba, Br, Cd, Co, Cu, Cr, Cs, Hf, Rb, Sb, Sc, Se, Ta, Th, U, and Zn and rare earths elements La, Ce, Eu, Nd, Sm, Lu, Tb, Yb). ICP OES was used for determination of the concentration levels of Al, Ba, Be, Bi, B, Cd, Co, Pb, Cu, Cr, Sn, Sr, Fe, Li, Mn, Mo, Ni, Tl, Ti, V and Zn. AAS for Cd and Pb quantification through graphite furnace (GF AAS) and Hg through cold vapor generation (CV AAS). Methodology validation according to precision and accuracy was performed by reference material analyses for the three analytical techniques used. Detection and quantification limits were calculated for each element evaluated. Seasonal variations (summer and winter), spatial and temporal (2005 e 2006) variations of metals and trace elements were also evaluated. In the Santos estuary, in general, metal and trace element concentrations , organic matter content and % of pellitic fraction found in the Santos channel (area 1) were higher than those of the Santos Bay (area 2) and São Vicente channel (area 3). Area 1 suffers high impact from industrial activities from the Cubatão region and Santos port. The sediments from station 14 (area 3, São Vicente channel), showed the same behavior of those from area 1, suffering influence from the industrial pole and located in a mangrove area. In comparison with TEL and PEL oriented values adopted by CETESB for toxic metals content in sediments, area 1 surpassed the TEL limits for some metals, mainly for Hg. Sediments from area 2 and 3 (except station 14), did not exceed the limits for most of the metals analyzed. Although the sediments from Cananéia region were composed mainly of sandy fractions, in some stations the pellitic fraction was greatly significant. From the results obtained in the region, the concentration levels of metals potentially available such as Cd, Cr, Cu, Hg, Ni, Pb and Zn were below the limits TEL and PEL oriented values and CONAMA 344/2004 resolution for the 3 areas assessed: area 1 (Cananéia sea), area 2 (Trapandé Bay) and area 3 (Cubatão sea). Enrichment Factor (EF) and Geoaccumulation index (Igeo), geochemical tools used for contamination assessment were used to evaluate the contamination level in both estuaries. Multivariate statistical analysis was applied to the results which were then compared to the results of other published studies in these regions (Santos/São Vicente and Cananéia).
4

Avaliação da concentração de micro e macroconstituintes do sedimento do reservatório Itupararanga/Sorocaba-SP / Micro and macro sediment constituint concentration assessment of the Itupararanga reservoir/Sorocaba-SP

Sharlleny Alves Silva 28 September 2012 (has links)
O reservatório de Itupararanga foi construído pela LIGHT para gerar energia elétrica, iniciando suas operações em 1912. É formado pela barragem das águas do rio Sorocaba, o qual possui como afluentes os rios Sorocamirim, Sorocabuçu e Una. O reservatório localiza-se em uma área de fortes pressões ambientais devido à poluição difusa da produção agrícola, à carga orgânica e uso e ocupação do solo com atividades antrópicas. Desde 2003 vem recebendo alertas da CETESB, devido à presença de grande quantidade de cianobactérias que têm se mantido até os dias atuais. Em decorrência dos problemas observados nesse reservatório, o presente estudo teve por objetivo, avaliar a concentração, dos micro e macroconstituintes em amostras de perfil sedimentar de quatro pontos distintos do reservatório. Para estas análises foram utilizadas as seguintes técnicas analíticas e os respectivos elementos analisados: Análise por Ativação com Nêutrons Instrumental (INAA): As, Ba, Br, Ca, Ce, Co, Cr, Cs, Eu, Fe, Hf, K, La, Lu, Na, Nd, Rb, Sb, Sc, Sm, Ta, Tb, Th, U, Yb e Zn; Espectrometria de Emissão Ótica com Plasma Indutivamente Acoplado (ICP OES): Ag, Al, Ba, Be, Co, Cr, Cu, Fe, Li, Mg, Mn, Mo, Ni, P, Sn, Sr, Ti, V e Zn; Espectrometria de Absorção Atômica com Forno de Grafite (FG AAS) As, Cd e Pb e Analisador Direto de Mercúrio: Hg total. A validação das metodologias utilizadas foi realizada por meio das análises de materiais de referencia certificados. Os resultados obtidos foram comparados aos valores de referência NASC (North American Shale Comosite) e UCC (Upper Continental Crust). Foram calculados o fator de enriquecimento (FE) e o índice de geoacumulação (Igeo), ferramentas usadas para avaliação da presença de fontes de poluição antrópicas. As concentrações dos metais obtidos por ICP OES e FG AAS foram comparadas aos valores orientadores TEL e PEL do Conselho Canadense de Ministros do Meio Ambiente (CCME) e adotado pela CETESB. A partir desse estudo, foi possível realizar um diagnóstico da qualidade e a carga de fósforo contida nos sedimentos do reservatório, direcionando para ações corretivas que antecipem um dano maior a qualidade do reservatório. / The Itupararanga reservoir was constructed by LIGHT for generating electrical energy, starting its operations 1912. It is formed by the barrage of the waters of the Sorocaba river, formed by the rivers Sorocamirim, Sorocabuçu and Una. The reservoir finds itself in an area of strong environmental pressures due to the diffuse pollution from the agricultural production and the organic load and the use and the occupation of the soil with anthropic activities. Since 2003 it keeps receiving alerts from CETESB due to the presence of cyanobacteria that continues today. In its waters there is the presence of a toxicity which did not correlate with the results of chemical analyzes performed. Due to the problems observed in this reservoir, the present study aimed to evaluate the concentration of micro and macro constituents in samples of sedimentary profile of four different reservoir points. For these analyzes the following analytical techniques were used, with the respective elements analyzed: Analysis by Instrumental Neutron Activation (INAA): As, Ba, Br, Ca, Ce, Co, Cr, Cs, Eu, Fe, Hf, K, La, Lu, Na, Nd, Rb, Sb, Sc, Sm, Ta, Tb, Th, U, Yb and Zn; Optical Emission Spectrometry with Inductively Coupled Plasma (ICP OES): Ag, Al, Ba, Be, Co, Cr, Cu, Fe, Li, Mg, Mn, Mo, Ni, P, Sn, Sr, Ti, V and Zn; Atomic Absorption Spectrometry with Graphite Furnace (FG AAS) As, Cd and Pb and Direct Mercury Analyzer: total Hg. The validation of used methodologies was performed by the analysis of certified reference materials. The results obtained were compared to reference values NASC (North American Shale Comosite), UCC (Upper Continental Crust). The enrichment factors (EF) and the geoaccumulation index (Igeo), were calculated; they are tools used to evaluate the presence of anthropic pollution sources. The metal concentrations obtained by ICP OES and FG AAS were compared to the guiding values TEL and PEL from the Canadian Council of Ministers of the Environment (CCME) and adopted by CETESB. From this study, it was possible to make a diagnosis of the quality and load of phosphorus in the reservoir sediments, directing to corrective actions that prevent greater harm to the quality of the reservoir.
5

Avaliação da concentração de metais e outros elementos de interesse em amostras de sedimentos dos estuários de Santos/São Vicente e Cananéia, Estado de São Paulo, Brasil / Metal and trace element sediment assessment from two estuarine systems: Santos/São Vicente and Cananéia, State of São Paulo, Brazil

Amorim, Eduardo Paulo de 10 October 2012 (has links)
No presente trabalho foram avaliados os teores de alguns metais tóxicos como Cd, Hg e Pb, outros elementos maiores e traço em amostras de sedimentos superficiais, provenientes de dois sistemas sob diferentes graus de ação antrópica, o sistema estuarino de Santos/São Vicente e na porção sul do sistema estuarino lagunar de Cananéia, ambos no litoral do Estado de São Paulo. Foram coletados sedimentos em 16 estações no estuário de Santos/São Vicente e 13 estações no estuário de Cananéia, durante o verão e inverno de 2005 e 2006, em ambos os estuários. Foram utilizadas 3 técnicas analíticas: NAA, AAS e ICP OES. Pela técnica de ativação neutrônica (NAA) foram determinados os teores dos elementos maiores (Ca, Fe e Na), elementos traço (As, Ba, Br, Cd, Co, Cu, Cr, Cs, Hf, Rb, Sb, Sc, Ta, Th, U, Zn e terras raras La, Ce, Eu, Nd, Sm, Lu, Tb, Yb). Pela técnica de espectrometria de emissão ótica com plasma indutivamente acoplado (ICP OES), foram avaliados os teores de Al, Ba, Be, Bi, Co, Cu, Cr, Fe, Li, Mn, Mo, Ni, Sr e Zn. Pela técnica de espectrometria de absorção atômica atômica (AAS), foram determinados por forno de grafite (GF AAS) Cd e Pb, e pela técnica de geração de vapor frio (CV AAS), o Hg. As metodologias analíticas foram validadas quanto à precisão e exatidão, por meio da análise de materiais de referência certificados. Foram calculados os limites de detecção e quantificação, para cada elemento analisado, para as diferentes técnicas analíticas. Foram avaliadas também as variações espaciais, sazonais (inverno e verão) e temporais (2005 e 2006) dos metais e elementos traço nos sedimentos. No estuário de Santos/São Vicente, em geral, as concentrações de metais e elementos traço, teores de matéria orgânica e % da fração pelítica encontrados no canal de Santos (área 1), foram maiores do que na baía de Santos (área 2) e no canal de São Vicente (área 3). A área 1 sofre grande impacto das atividades industriais da região de Cubatão e do porto de Santos. Os sedimentos da estação 14 (área 3, Canal de São Vicente) apresentaram comportamento semelhante aos da área 1, sofrendo influência do polo industrial e por estar localizado em uma área de mangue. Na comparação com os valores orientadores TEL e PEL adotados pela CETESB para os metais tóxicos em sedimentos, verificou-se que a área 1 ultrapassou os limites TEL para alguns dos metais, principalmente para Hg. Os sedimentos da área 2 e da área 3 (exceto estação 14), não ultrapassaram os valores limites para a maioria dos metais analisados. Apesar dos sedimentos do estuário de Cananéia serem compostos principalmente por frações de areia, em algumas estações a fração pelítica foi bastante significativa. A partir dos resultados obtidos na região de Cananéia, observou-se que as concentrações potencialmente disponíveis dos metais Cd, Pb, Hg, Cr, Cu, Ni e Zn se encontraram abaixo dos limites estabelecidos pela legislação CONAMA 344/2004 para sedimentos e dos limites TEL e PEL, para as 3 áreas avaliadas: área 1 (Mar de Cananéia), área 2 (Baia de Trapandé) e área 3 (Mar de Cubatão). Fator de Enriquecimento (FE) e índice de geoacumulação (Igeo), ferramentas geoquímicas para avaliação da contaminação de metais e elementos traço, foram usadas para avaliar os níveis de contaminação em ambos os estuários. Aos resultados obtidos foi aplicada análise estatística multivariada e por último, os resultados foram comparados com outros dados publicados na literatura para as regiões em estudo (Santos/São Vicente e Cananéia). / This study evaluated some toxic metals such as Cd, Hg and Pb and some other major and trace elements in surface sediment samples, from two different systems under different degrees of anthropogenic actions: the estuarine system of Santos/São Vicente and the southern part of the Cananéia estuary, both on the São Paulo state coast. Sediment samples were collected in 16 stations in the Santos/São Vicente estuary and 13 stations in the Cananéia estuary, during summer and winter of 2005 and 2006, in both estuaries. Three analytical techniques were used: NAA, AAS and ICP OES. NAA was used for the quantification of major element concentration levels (Ca, Fe and Na), trace elements (As, Ba, Br, Cd, Co, Cu, Cr, Cs, Hf, Rb, Sb, Sc, Se, Ta, Th, U, and Zn and rare earths elements La, Ce, Eu, Nd, Sm, Lu, Tb, Yb). ICP OES was used for determination of the concentration levels of Al, Ba, Be, Bi, B, Cd, Co, Pb, Cu, Cr, Sn, Sr, Fe, Li, Mn, Mo, Ni, Tl, Ti, V and Zn. AAS for Cd and Pb quantification through graphite furnace (GF AAS) and Hg through cold vapor generation (CV AAS). Methodology validation according to precision and accuracy was performed by reference material analyses for the three analytical techniques used. Detection and quantification limits were calculated for each element evaluated. Seasonal variations (summer and winter), spatial and temporal (2005 e 2006) variations of metals and trace elements were also evaluated. In the Santos estuary, in general, metal and trace element concentrations , organic matter content and % of pellitic fraction found in the Santos channel (area 1) were higher than those of the Santos Bay (area 2) and São Vicente channel (area 3). Area 1 suffers high impact from industrial activities from the Cubatão region and Santos port. The sediments from station 14 (area 3, São Vicente channel), showed the same behavior of those from area 1, suffering influence from the industrial pole and located in a mangrove area. In comparison with TEL and PEL oriented values adopted by CETESB for toxic metals content in sediments, area 1 surpassed the TEL limits for some metals, mainly for Hg. Sediments from area 2 and 3 (except station 14), did not exceed the limits for most of the metals analyzed. Although the sediments from Cananéia region were composed mainly of sandy fractions, in some stations the pellitic fraction was greatly significant. From the results obtained in the region, the concentration levels of metals potentially available such as Cd, Cr, Cu, Hg, Ni, Pb and Zn were below the limits TEL and PEL oriented values and CONAMA 344/2004 resolution for the 3 areas assessed: area 1 (Cananéia sea), area 2 (Trapandé Bay) and area 3 (Cubatão sea). Enrichment Factor (EF) and Geoaccumulation index (Igeo), geochemical tools used for contamination assessment were used to evaluate the contamination level in both estuaries. Multivariate statistical analysis was applied to the results which were then compared to the results of other published studies in these regions (Santos/São Vicente and Cananéia).
6

Avaliação da concentração de micro e macroconstituintes do sedimento do reservatório Itupararanga/Sorocaba-SP / Micro and macro sediment constituint concentration assessment of the Itupararanga reservoir/Sorocaba-SP

Silva, Sharlleny Alves 28 September 2012 (has links)
O reservatório de Itupararanga foi construído pela LIGHT para gerar energia elétrica, iniciando suas operações em 1912. É formado pela barragem das águas do rio Sorocaba, o qual possui como afluentes os rios Sorocamirim, Sorocabuçu e Una. O reservatório localiza-se em uma área de fortes pressões ambientais devido à poluição difusa da produção agrícola, à carga orgânica e uso e ocupação do solo com atividades antrópicas. Desde 2003 vem recebendo alertas da CETESB, devido à presença de grande quantidade de cianobactérias que têm se mantido até os dias atuais. Em decorrência dos problemas observados nesse reservatório, o presente estudo teve por objetivo, avaliar a concentração, dos micro e macroconstituintes em amostras de perfil sedimentar de quatro pontos distintos do reservatório. Para estas análises foram utilizadas as seguintes técnicas analíticas e os respectivos elementos analisados: Análise por Ativação com Nêutrons Instrumental (INAA): As, Ba, Br, Ca, Ce, Co, Cr, Cs, Eu, Fe, Hf, K, La, Lu, Na, Nd, Rb, Sb, Sc, Sm, Ta, Tb, Th, U, Yb e Zn; Espectrometria de Emissão Ótica com Plasma Indutivamente Acoplado (ICP OES): Ag, Al, Ba, Be, Co, Cr, Cu, Fe, Li, Mg, Mn, Mo, Ni, P, Sn, Sr, Ti, V e Zn; Espectrometria de Absorção Atômica com Forno de Grafite (FG AAS) As, Cd e Pb e Analisador Direto de Mercúrio: Hg total. A validação das metodologias utilizadas foi realizada por meio das análises de materiais de referencia certificados. Os resultados obtidos foram comparados aos valores de referência NASC (North American Shale Comosite) e UCC (Upper Continental Crust). Foram calculados o fator de enriquecimento (FE) e o índice de geoacumulação (Igeo), ferramentas usadas para avaliação da presença de fontes de poluição antrópicas. As concentrações dos metais obtidos por ICP OES e FG AAS foram comparadas aos valores orientadores TEL e PEL do Conselho Canadense de Ministros do Meio Ambiente (CCME) e adotado pela CETESB. A partir desse estudo, foi possível realizar um diagnóstico da qualidade e a carga de fósforo contida nos sedimentos do reservatório, direcionando para ações corretivas que antecipem um dano maior a qualidade do reservatório. / The Itupararanga reservoir was constructed by LIGHT for generating electrical energy, starting its operations 1912. It is formed by the barrage of the waters of the Sorocaba river, formed by the rivers Sorocamirim, Sorocabuçu and Una. The reservoir finds itself in an area of strong environmental pressures due to the diffuse pollution from the agricultural production and the organic load and the use and the occupation of the soil with anthropic activities. Since 2003 it keeps receiving alerts from CETESB due to the presence of cyanobacteria that continues today. In its waters there is the presence of a toxicity which did not correlate with the results of chemical analyzes performed. Due to the problems observed in this reservoir, the present study aimed to evaluate the concentration of micro and macro constituents in samples of sedimentary profile of four different reservoir points. For these analyzes the following analytical techniques were used, with the respective elements analyzed: Analysis by Instrumental Neutron Activation (INAA): As, Ba, Br, Ca, Ce, Co, Cr, Cs, Eu, Fe, Hf, K, La, Lu, Na, Nd, Rb, Sb, Sc, Sm, Ta, Tb, Th, U, Yb and Zn; Optical Emission Spectrometry with Inductively Coupled Plasma (ICP OES): Ag, Al, Ba, Be, Co, Cr, Cu, Fe, Li, Mg, Mn, Mo, Ni, P, Sn, Sr, Ti, V and Zn; Atomic Absorption Spectrometry with Graphite Furnace (FG AAS) As, Cd and Pb and Direct Mercury Analyzer: total Hg. The validation of used methodologies was performed by the analysis of certified reference materials. The results obtained were compared to reference values NASC (North American Shale Comosite), UCC (Upper Continental Crust). The enrichment factors (EF) and the geoaccumulation index (Igeo), were calculated; they are tools used to evaluate the presence of anthropic pollution sources. The metal concentrations obtained by ICP OES and FG AAS were compared to the guiding values TEL and PEL from the Canadian Council of Ministers of the Environment (CCME) and adopted by CETESB. From this study, it was possible to make a diagnosis of the quality and load of phosphorus in the reservoir sediments, directing to corrective actions that prevent greater harm to the quality of the reservoir.
7

Evaluación del efecto raleador de cianamida hidrogenada en manzanos var. red king oregon, braeburn y red chief

García Palominos, Cecilia Loreto January 2005 (has links)
Memoria para optar al Título Profesional de Ingeniero Agrónom o Mención: Fruticultura
8

Continuous Zeolite Crystallization in Micro-Batch Segmented Flow

Vicens, Jim 25 April 2018 (has links)
Zeolites are porous aluminosilicates that occur both naturally and synthetically, having numerous applications in catalysis, adsorption and separations. Despite over a half century of characterization and synthetic optimization of hundreds of frameworks, the exact mechanism of synthesis remains highly contested, with crystallization typically occurring under transport-limited regimes. In this work, a microcrystallization reactor working under segmented oscillatory flow has been designed to produce a semi-continuous flow of zeolite A. The fast injection of the reactants in a mixing section forms droplets of aqueous precursors in a stream of paraffin, dispersing microdroplets and avoiding any clog from occurring in the system. The crystallization occurred in the system at atmospheric pressure and isothermal conditions (65ºC). This allowed for a rather slow crystallization kinetics which was important to study and highlight the different crystallization mechanisms between flow and batch synthesis. The morphology, size distributions, crystallinity, and porosity were examined by ex-situ characterization of the samples by scanning electron microscopy, X-ray diffraction, Raman spectroscopy, and N2 Physisorption to support the conclusions drawn. The size distribution of the particles achieved in the flow reactor was conclusively narrower than the distribution achieved in the batch reactor. The average size of the crystals for both synthesis methods is reported as 400 nm and the crystallinity achieved was comparable between the two. However, the morphology was quite different between the two systems, the flow products having a much higher mesoporosity due to the presence of crystal aggregates at high crystallinity when compared to the batch crystals. Finally, extended crystallization times leads to a decline of the crystallinity of the product, which might be explained by the metastable state of zeolites in solution.
9

Continuous Zeolite Crystallization in Micro-Batch Segmented Flow

Vicens, Jim 25 April 2018 (has links)
Zeolites are porous aluminosilicates that occur both naturally and synthetically, having numerous applications in catalysis, adsorption and separations. Despite over a half century of characterization and synthetic optimization of hundreds of frameworks, the exact mechanism of synthesis remains highly contested, with crystallization typically occurring under transport-limited regimes. In this work, a microcrystallization reactor working under segmented oscillatory flow has been designed to produce a semi-continuous flow of zeolite A. The fast injection of the reactants in a mixing section forms droplets of aqueous precursors in a stream of paraffin, dispersing microdroplets and avoiding any clog from occurring in the system. The crystallization occurred in the system at atmospheric pressure and isothermal conditions (65ºC). This allowed for a rather slow crystallization kinetics which was important to study and highlight the different crystallization mechanisms between flow and batch synthesis. The morphology, size distributions, crystallinity, and porosity were examined by ex-situ characterization of the samples by scanning electron microscopy, X-ray diffraction, Raman spectroscopy, and N2 Physisorption to support the conclusions drawn. The size distribution of the particles achieved in the flow reactor was conclusively narrower than the distribution achieved in the batch reactor. The average size of the crystals for both synthesis methods is reported as 400 nm and the crystallinity achieved was comparable between the two. However, the morphology was quite different between the two systems, the flow products having a much higher mesoporosity due to the presence of crystal aggregates at high crystallinity when compared to the batch crystals. Finally, extended crystallization times leads to a decline of the crystallinity of the product, which might be explained by the metastable state of zeolites in solution.
10

Caracterização físico-química da cerâmica do sítio arqueológico São Paulo II / Physical and chemical characterization of ceramics from archaeological site São Paulo II

Ribeiro, Rogério Baria 27 May 2013 (has links)
A arqueometria é uma área consolidada, com ampla utilização de métodos analíticos nucleares destrutivos e não destrutivos para caracterização, proteção e restauração de peças arqueológicas. O presente projeto teve como objetivo estudar a composição química elementar de amostras de fragmentos cerâmicos encontradas no sítio arqueológico São Paulo II localizado na calha do rio Solimões, próximo ao município de Coari na Amazônia Brasileira. Realizou-se a caracterização das amostras pela determinação de Ce, Co, Cr, Cs, Eu, Fe, Hf, K, La, Lu, Na, Nd, Sb, Sm, Rb, Sc, Ta, Tb, Th, U, Yb and Zn por meio da análise por ativação com nêutrons (NAA). A partir da composição química da cerâmica, foi possível definir o agrupamento de amostras em função da similaridade/dissimilaridade da composição química presente no material cerâmico. O agrupamento foi interpretado por métodos estatísticos multivariados como análise de cluster, análise de componentes principais e análise de discriminante. Foram selecionadas, a partir da formação dos grupos, 7 cerâmicas com o objetivo de elaborar o horizonte temporal do sítio, realizado por termoluminescência (TL) e ressonância paramagnética eletrônica (EPR). A temperatura de queima da cerâmica foi determinada em 6 fragmentos por meio da técnica de EPR. Os resultados apresentados neste trabalho podem contribuir com os estudos arqueológicos sobre a dinâmica da ocupação da Amazônia Central anterior à colonização Brasileira. / Archaeometry is currently a well established field in the archaeological sciences. The nuclear method for analysis of chemical elements is one of the important instruments for the characterization of the archaeological materials and has influences on the preservation and restoration. From the chemical and physical analyses it is possible to infer technical processes in ceramics manufacture and tools used by ancient people. Therefore, it contributes to the typology and to understand the roles of materials available in the archaeological sites, such as clays and lythic sources. Evidently, all the archaeological materials and sites are related to people that lived there a long time ago, and studies, as outlined above, reconstruct at least partially the history of such a population. This project aimed at studying the elementary chemical composition of 70 ceramic fragments samples from São Paulo II archaeological site, located along the Solimões River channel, next to Coari city, in Brazilian Amazon. The characterization of samples was performed by neutron activation analysis (NAA). By the determination of 22 elements in the ceramic fragments ( Ce, Co, Cr, Cs, Eu, Fe, Hf, K, La, Lu, Na, Nd, Sb, Sm, Rb, Sc, Ta, Tb, Th, U, Yb and Zn), it was possible to define groups of samples regarding the similarity/dissimilarity in elementary chemical composition. For such a task, the multivariate statistical methods employed were cluster analysis (CA), principal component analysis (PCA) and discriminant analysis (DA). Afterwards, seven ceramic fragments have been selected to elaborate the site temporal horizon using thermoluminescence (TL) and electron paramagnetic resonance (EPR) dating results. The EPR technique was also used to find the average firing temperature to produce the ceramics. The results of this research may contribute to the study on the occupation dynamics in the pre-colonial Brazilian Amazon.

Page generated in 0.4106 seconds