• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] METHODS BASED ON COMPUTATIONAL INTELLIGENCE TECHNIQUES FOR LOCALIZATION OF FIREARMS PROJECTILES INSERTED INTO THE HUMAN BODY, BY HIGH SENSITIVITY MAGNETIC MEASUREMENTS / [pt] MÉTODOS BASEADOS EM TÉCNICAS DE INTELIGÊNCIA COMPUTACIONAL PARA LOCALIZAÇÃO DE PROJÉTEIS DE ARMAS DE FOGO INSERIDOS NO CORPO HUMANO, POR MEIO DE MEDIÇÕES MAGNÉTICAS DE ALTA SENSIBILIDADE

JUAN DARIO TIMARAN JIMENEZ 16 November 2017 (has links)
[pt] Um dos casos clínicos mais frequentes na sociedade moderna envolve a localização e extração de projéteis de armas de fogo, que normalmente são feitos de chumbo, um material não ferromagnético. O desenvolvimento de uma técnica que possibilite a localização precisa destes auxiliará o procedimento de remoção cirúrgica, tendo vasta relevância e impactando diretamente no aumento da taxa de sobrevivência de pessoas feridas. Dessa forma, esta dissertação apresenta e discute duas novas abordagens baseadas em técnicas de inteligência computacional, objetivando a localização de projéteis de armas de fogo inseridos no corpo humano, a partir do processamento da informação contida em mapas de campo magnético. Em ambas as abordagens analisadas modela-se o projétil como uma esfera de raio a, localizado em um espaço de busca contido em um plano xy, o qual está situado a uma distância h do sensor no eixo z. As técnicas de localização requerem a geração de um campo magnético primário alternado por meio de um solenoide, o qual incide sobre o espaço de busca. Caso exista um projétil de arma de fogo nesta região, serão induzidas correntes parasitas no projétil, as quais, por sua vez, produzirão um campo magnético secundário, que pode ser medido por um sensor de alta sensibilidade localizado na extremidade do solenoide. Na primeira abordagem analisada, as posições x e y do projétil são determinadas por um algoritmo de janelamento que considera valores máximos e médios pertencentes aos mapas de campo magnético secundário. A determinação da distância h entre a esfera e o sensor foi obtida por meio de uma rede neural, e o raio da esfera a é estimado por um algoritmo genético. Na segunda abordagem, as quatro variáveis de interesse (x, y, h e a) são inferidas diretamente por um algoritmo genético. Os resultados obtidos são avaliados e comparados. / [en] In modern society, one of the most frequent clinical cases involves location and extraction of firearms projectiles, usually made of lead, a non-ferromagnetic material. The development of a technique that allows the precise location of these projectiles will aid their surgical removal, which has a great relevance because it contributes directly to the increase of the survival rate of wounded patients. Thus, this dissertation presents and discusses two new approaches based on computational intelligence techniques, aiming at locating firearm projectiles inserted into the human body, by processing the information contained in magnetic field maps. On both approaches, the projectile is modeled by a sphere with radius a, located on a search space contained in a xy plane that is situated at a distance h from the sensor, along the z axis. The proposed location techniques require the generation of a primary alternating magnetic field by means of a solenoid, which aims at inducing eddy currents in a firearm projectile contained in the search space. In turn, these currents will produce a secondary magnetic field, which can be measured by a high-sensitivity sensor located at the bottom of the solenoid. In the first developed technique, the x and y positions of the projectile were estimated by a windowing algorithm that takes into account maximum and mean values contained on the secondary magnetic field maps. In turn, the distance h between the sphere and the sensor is inferred by a neural network, and the radius of the sphere a is estimated by a genetic algorithm. In the second technique, the four variables of interest (x, y, h and a) are inferred directly by a genetic algorithm. The results obtained are evaluated and compared.
2

[pt] DETECÇÃO DE CORPOS ESTRANHOS METÁLICOS NÃO-FERROMAGNÉTICOS POR CORRENTES PARASITAS / [en] NON-FERROMAGNETIC METALLIC FOREIGN BODY DETECTION BY EDDY CURRENTS

LEONARDO GOUVEA E SILVA FORTALEZA 07 December 2016 (has links)
[pt] Projéteis de chumbo (não-ferromagnéticos) são corpos estranhos comuns na prática médica. Métodos convencionais de localização utilizam radiações ionizantes, impondo riscos à saúde e procedimentos que duram várias horas e tipicamente terminam malsucedidos. Mapas de campos magnéticos obtidos não-invasivamente e inocuamente com SQUIDs beneficiam a localização de agulhas metálicas ferromagnéticas, reduzindo o tempo de remoção bem-sucedida de 6 horas para 10 minutos. SQUIDs são os magnetômetros mais sensíveis, entretanto requerem temperaturas criogênicas, levando a altos custos e baixa portabilidade que impedem a difusão do uso clínico. O objetivo é desenvolver um dispositivo para localizar corpos estranhos metálicos não-ferromagnéticos visando remoção cirúrgica, respeitando requerimentos de projeto: alta sensibilidade, inocuidade, não-invasividade, baixo custo, segurança, portabilidade, facilidade de uso e operação em temperatura ambiente. Sensores GMR e GMI são considerados alternativas mais adequadas. Modelos teóricos de eletrodinâmica clássica aplicados às correntes parasitas servem como base. Dois sistemas eletrônicos são desenvolvidos em configuração gradiométrica para remover interferência ambiente, usando elementos sensores GMR e GMI disponíveis comercialmente. O desempenho é obtido com resultados de simulações, provando a capacidade de detecção de níveis esperados de densidade de fluxo magnético para certos raios de projéteis e distâncias. O Sistema GMI é mais qualificado, sua mais alta sensibilidade e melhor resolução favorecem maiores faixas de medição, inocuidade, segurança e facilidade de uso. Os resultados demonstram a viabilidade dos elementos sensores GMI nessa aplicação. Os benefícios de baixo custo, maior portabilidade e segurança facilitam a utilização clínica de técnicas de localização para corpos estranhos metálicos não-ferromagnéticos mais inócuas e efetivas. / [en] Lead projectiles (non-ferromagnetic) are common foreign bodies in the medical practice. Conventional means of location use ionizing radiation, pose health risks and lead to procedures that last several hours, typically ending unsuccessfully. Magnetic field maps obtained non-invasively and innocuously with SQUIDs benefit the location of ferromagnetic metallic needles, reducing the time of successful removal from 6 hours to 10 minutes. SQUIDs are currently the most sensitive magnetometers, however require cryogenic temperatures, leading to high cost and low portability which prevent widespread clinical use. The objective is to design a device for locating non-ferromagnetic metallic foreign bodies for surgical removal, respecting project requirements of: high sensitivity, innocuousness, non-invasiveness, low cost, safety, portability, ease of use and room temperature operation. GMR and GMI sensors are considered as more suitable alternatives. Classical electrodynamics theoretical models applied to eddy currents induction serve as framework. Two electronic location systems are developed in gradiometric configuration to remove environmental interference, using commercially available GMR and GMI sensor elements. System performance is obtained from simulation results, demonstrating the capability of detecting the magnetic flux density levels expected under certain projectile radii and distances. The GMI system is more qualified, as its higher sensitivity and improved resolution favors larger measurement ranges, innocuousness, safety and ease of use. The results prove the viability of using GMI sensor elements in this application. The benefits of lower cost, higher portability and safety facilitate the clinical use of more innocuous and effective location techniques for non-ferromagnetic metallic foreign bodies.

Page generated in 0.0229 seconds