• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] METROLOGICAL RELIABILITY OF THE ANALYTICAL METHOD BY X-RAY FLUORESCENCE FOR STEEL INDUSTRY MATERIALS / [pt] CONFIABILIDADE METROLÓGICA NA DETERMINAÇÃO DE ESPÉCIES QUÍMICAS EM MATERIAIS SIDERÚRGICOS POR ESPECTROMETRIA DE FLUORESCÊNCIA DE RAIOS-X

EDGAR ADRIAN DE OLIVEIRA 15 December 2011 (has links)
[pt] O objetivo da dissertação é avaliar a confiabilidade metrológica da técnica de fluorescência de raios-X utilizada em análises quantitativas de espécies químicas presentes em materiais siderúrgicos utilizados na produção do aço. O estudo da técnica e a avaliação da capacidade do equipamento analítico associado às etapas de recebimento, preparação e análise das amostras permitem definir os itens críticos de controle para monitoramento e garantia dos resultados emitidos. Como motivação, o interesse em garantir a aplicação de um método já conhecido às novas demandas de análises químicas, suprindo as necessidades dos clientes, otimizando-se, assim, os serviços prestados no laboratório responsável pelo processo de controle de qualidade da ArcelorMittal Tubarão. A metodologia de desenvolvimento do trabalho baseou-se nas boas práticas da metrologia, assegurando que medições sejam adequadamente realizadas, reduzindo o consumo e o desperdício de matéria-prima e gerando ganhos de produtividade. Em conformidade às recomendações do Guia EURACHEM, a validação da técnica levou em conta a confirmação do analito, seletividade/especificidade, limite de detecção, limite de quantificação, recuperação, intervalo de medição, linearidade, exatidão, veracidade, precisão (repetitividade, precisão intermediária) e robustez. Dentre os resultados, o trabalho valida o método para o trabalho de rotina, qualificando a fluorescência de raios-X como método de análise para os materiais analisados no laboratório. Como conclusão o estudo da metodologia de validação metrológica deixa uma fonte bibliográfica da técnica e do equipamento utilizados, de forma a difundir estes princípios. Outra contribuição do presente trabalho foi a possibilidade de expansão da referida técnica para outras análises químicas realizadas no laboratório da ArcelorMittal Tubarão. / [en] This master’s degree dissertation purpose is evaluate, by means of metrological validation techniques, the reliability of the analytical method by Xray fluorescence, used in quantitative analysis of chemical species presents in various materials used in steel production process. The method study and the evaluation of the analytical equipment capacity associated with the correct understanding of the steps of receiving, preparation and analysis of samples will define the critical issues of control to guarantee the emitted results. As motivation, the interest for ensuring the implementation of a method already known in the new demands of chemical analysis, supplying the needs of customers, optimizing, thus, the services provided in the laboratory responsible for quality control of ArcelorMittal Tubarão. The methodological study development was based on good practice of metrology in order to ensure adequate measurements made during a production process, reducing consumption and waste of raw materials and generating productivity gains. In accordance with the EURACHEM Guide, the method validation took into account the Confirmation of identity, Selectivity / Specificity, Limit of detection, Limit of quantification, Recovery, Working and linear ranges, Accuracy, Trueness, Precision (repeatability, intermediate precision) and Robustness. Among the results, the study validates the method for routine work, qualifying X-ray fluorescence as a method of analysis for materials tested in the laboratory. As conclusion the study of the metrological validation methodology leaves a bibliographic source of the method and equipment used, in order to spread these principles. Another contribution of this work was the possibility of expanding this technique to other analysis realized in the laboratory of ArcelorMittal Tubarão.
2

[en] METROLOGICAL EVALUATION AND INTERLABORATORY COMPARISON OF THE MEASUREMENT TECHNIQUE OF SULFUR IN DIESEL OIL BY MEANS OF X-RAY FLUORESCENCE / [pt] AVALIAÇÃO METROLÓGICA E COMPARAÇÃO INTERLABORATORIAL DA TÉCNICA DE MEDIÇÃO DE ENXOFRE EM ÓLEO DIESEL POR FLUORESCÊNCIA DE RAIOS-X

OLIVIA WOYAMES PINTO 14 January 2004 (has links)
[pt] Os compostos de enxofre estão presentes em todos os derivados de petróleo bruto. Para o meio ambiente, dois poluentes resultantes da queima do óleo diesel são considerados críticos, o material particulado (MP) e os óxidos de nitrogênio. Sendo que o primeiro tem relação direta com o teor de enxofre no óleo diesel e a presença do segundo nos gases de escapamento tem relação primordial com o projeto de motor. Daí a importância do monitoramento do teor de enxofre em óleo diesel, cuja qualidade e a rastreabilidade de medição foi verificada em seis laboratórios do Rio de Janeiro através de uma participação em um Programa de Comparação Interlaboratorial. Houve a necessidade de enquadramento da técnica de medição de enxofre por fluorescência de raios-x (FRX) baseado na norma ASTM D 2622-98 em cumprimento aos requisitos da ABNT ISO/IEC 17025, a qual especifica a competência para a realização de ensaios e/ou calibrações. O objetivo deste trabalho foi realizar uma análise metrológica do ensaio de determinação do teor de enxofre em óleo diesel por fluorescência de raios-x. Foram utilizados como parâmetros de desempenho, a faixa de trabalho, a linearidade, o limite de detecção e de quantificação, a exatidão, a repetitividade, a reprodutibilidade e a incerteza de medição. Nesta análise metrológica foi observado que o uso de material de referência certificado e os parâmetros de desempenho no limite de 95,45 por cento de confiança apresentaram resultados compatíveis com a metodologia. Quanto ao desempenho no ensaio de proficiência dos laboratórios participantes, o programa orientou-os na identificação de erros não detectados pelo próprio laboratório, propiciando o aprimoramento das técnicas analíticas, melhoria na qualidade das medições e maior confiabilidade dos resultados obtidos. / [en] Sulfur compounds are among the components of most crude oils and their products. When burning diesel fuel, two main pollutants are discharged into the atmosphere. Particulate matter (PM) is directly related to the amount of the sulfur content in the diesel fuel. Nitrogen oxides in the exhaust gases are a direct function of the engine design and operating conditions. It is therefore important to monitor the sulfur content of the diesel fuel. In this dissertation, its measurement quality and traceability were determined when comparing the results obtained by six laboratories, which are operating in the state of Rio de Janeiro. The x-ray fluorescence (XRF) sulfur measurement technique, as described by the ASTM D2622-98 standard, was used by all the laboratories in this intercomparison program, which was conducted following the ABNT ISO/IEC 17025 standard. The objective of this work is thus to perform a metrological evaluation of the sulfur content in the diesel fuel through the x-ray fluorescence technique. Working range, linearity, resolution, accuracy, repeatability, reproducibility and measurement uncertainty are the parameters used for the performance evaluation, as referred to the 95,45 percent confidence level. The metrological evaluation showed that the use of a certified reference material, together with the performance evaluation parameters, produced results, which were compatible with the used methodology. This intercomparison program also helped the laboratories to identify nonpreviously detected measurement errors, thus improving the measurement quality and reliability in the analytical technique.

Page generated in 0.0312 seconds