1 |
[en] CORONA EFFECTS NUMERICAL SIMULATION IN SINGLE PHASE TRANSMISSION LINES / [pt] SIMULAÇÃO NUMÉRICA DO EFEITO CORONA EM LINHAS DE TRANSMISSÃO MONOFÁSICASMARCOS ANDRE DA FROTA MATTOS 26 August 2009 (has links)
[pt] Uma análise teórica, comparativa e de sensibilidade é feita com quatro modelos básicos para o efeito corona em linhas de transmissão monofásicas. A análise de ocorrência de choque em linhas de transmissão é também considerada na análise os modelos. Um algoritmo computacional é desenvolvido para estudo de transitórios eletromagnéticos em linhas de transmissão monofásicas. Por fim são analisados casos interessantes do ponto de vista da Engenharia Elétrica. / [en] The corona effect on monophasic transmission lines was subjected to a theoretical comparative sensibility analysis. Four basic models were used. The analysis of shock occurrence in transmission lines was also considered in the analysis of the models. A computational algorithms was developed to study electromagnetic transients on monophasic transmission lines. Finally, interesting cases from the Electrical Engeneering standpoint were analysed.
|
2 |
[en] STEADY-STATE VOLTAGE STABILITY ASSESSMENT METHOD / [pt] AVALIAÇÃO ESTÁTICA DA ESTABILIDADE DE TENSÃO EM REDES ELÉTRICASJORGESON OLIVEIRA RODRIGUES DOS SANTOS 31 August 2006 (has links)
[pt] Atualmente os sistemas elétricos altamente carregados
estão enfrentando um crescente risco de estabilidade de
tensão na medida que restrições ambientais e incertezas
econômicas limitam o investimento em novas linhas de
transmissão. Uma revisão dos problemas ocorridos em vários
países indicam claramente que o problema de estabilidade
de tensão é real e que o pior ainda está por vir [1].
Portanto existe a necessidade do desenvolvimento de
ferramentas analíticas capazes de prever o colapso de
tensão em redes complexas. Estas ferramentas devem ser
capazes de quantificar com precisão as margens de
estabilidade e os limites de transferência de potência,
identificando os pontos fracos e as áreas susceptíveis á
estabilidade de tensão.
Um método para determinação das condições de estabilidade
local de tensão é mostrado. A eficiência computacional
desta ferramenta analítica é enfatizada em estudos de
análise de cotingência.
Estudos comparativos mostram a influência do modelo da
carga estática, dos equivalentes de redes e da
representação dos limites de geração ou absorção de
potência reativa a partir da curva de capabilidade da
máquina síncrona, no índice que avalia a estabilidade
local de tensão.
Um estudo sobre o determinante da matriz que serve como
índice que avalia a estabilidade local de tensão.
Neste trabalho são propostos novos estudos para dar
continuidade aos avanços obtidos até o momento. / [en] Nowadays, heavy loaded eletric power systems are facing
voltage stability problems due to environmental
restrictions and budget cuts. Power systems incidents
involving voltage stability clearly show that it is real
problem and worse conditions are expected [1]. Therefore,
there is a need of developing analytical tools to detect
voltage collapse in complex networks. These tools must
show, with good accuracy, stability ranges and power
transfer limits, identifying weak nodes and susceptible
areas to voltage stability.
It is show a method to determine local voltage stability
conditions and its computational efficiency is emphasized
through contingency analysis studies.
Comparative studies show the influence of static load
model, network equivalent and reactive power
generation/absorption limits representation using the
synchronous machine capability curve, over the index which
evaluates local voltage stability.
It is show a study about the determinant which plays as an
index to evaluate local voltage stability.
Suggestions are made for future research.
|
3 |
[en] PROBABILISTIC LOAD FLOW CONSIDERING DEPENDENCE BETWEEN INPUT NODAL POWERS / [pt] FLUXO DE POTÊNCIA PROBABILÍSTICO CONSIDERANDO DEPENDÊNCIA ENTRE POTÊNCIA NODAISVINICIUS LEAL ARIENTI 10 May 2007 (has links)
[pt] O fluxo de potência probabilístico é considerado uma
técnica eficiente na obtenção de índices de segurança,
tais como: a probabilidade de sobrecarga nas linhas de
transmissão, probabilística de sobretensão em barramentos,
etc., os quais são medidas extremamente úteis no
planejamento e na operação de sistemas de potência. Este
índices são obtidos dada a capacidade de tal algoritmo
considerar a natureza probabilística das cargas em uma
única solução.
Nesta tese, a dependência entre as potências nodais é
modelada de forma a considerar fatores ambientais e
sociais como também o critério de pré-despacho usado no
balanço da potência ativa do sistema. Estes aspectos são
então incluídos no fluxo de potência probabilístico e o
novo algoritmo é testado com dois sistemas de potência.
O novo algoritmo de fluxo de potência probabilístico
considerando dependências entre as potências nodais
proposto por esta tese pode ser visto como uma técnica
bastante realística para avaliar os riscos de insegurança
dos sistemas de potência. / [en] Probabilistic load flow can be considered an efficient
technique in order to essess security índices, such as:
the probability of a line being greater than its thermal
rating, probability of a busbar voltage being outside its
operational constraints, etc., which are extremely useful
measurements in planning and operation of power systems.
These indices are schieved due to the capability of such
algorithm in recognising the probabilistic nature of
generation and load within one solution.
In this thesis, the dependence between nodal powers is
modelled in order to account environmental and social
factors and the unit commitment criteria used to balance
the system active power. These aspects are then included
in the conventional probabilistic load flow and the new
algorithm is tested with two power systems.
The new probabilistic load flow algorithm considering
dependence between nodal powers proposed by this thesis
can be seen as very realistic technique to evaluate system
security risks.
|
4 |
[en] DETERMINATION OF THE LONGITUDINAL COMPONENT OF ELETROMAGNETIC FIELSD PRODUCED BY SURFACE CURRENT DENSITIES, IN APPLICATIONS OF DIADIC GREENNULLS FUNCTION / [pt] DETERMINAÇÃO PELO MÉTODO DAS DIÁDICAS DE GREEN DA COMPONENTE LONGITUDINAL DE CAMPOS ELETROMAGNÉTICOS EXCITADOS POR DENSIDADES SUPERFICIAIS DE CORRENTEOSCAR HERNAN POLANCO PEREZ 17 April 2006 (has links)
[pt] Neste trabalho desenvolve-se uma técnica para determinação
da componente longitudinal do campo elétrico gerado por
uma densidade superficial de corrente. A metodologia
proposta baseia-se na diádica de Green da região em
consideração, sendo estudadas regiões interiores em que
existe uma solução analítica da equação de onda escalar em
coordenadas ortogonais e regiões exteriores, em sistemas
de coordenadas esféricas e cilíndricas. Para cada uma das
soluções, mostra-se a convergência da expressão obtida
para a componente longitudinal do campo elétrico, expressa
por uma série ou integrais de funções modais. Baseado na
metodologia desenvolvida, elabora-se um modelo de análise
para determinação de campos e impedância característica em
cabos coaxiais de seção arbitrária. O modelo é aplicado a
cabos de seção circular e retangular. A metodologia de
determinação de campos por diádicas de Green é ainda
aplicada à análise de cabos coaxiais de seção retangular,
com estais de fixação do condutor interno, localizados
periodicamente. / [en] It is developed a method for the determination of the
longitudinal component of the electric field generated by
a surface current density in the interior or the exterior
regions.
The proposed method is based on the dyadic Green´s
function of the region under consideration, beeing
analysed interior regions, assuming the knowledge of the
analytical solution for the scalar wave equation in the
orthogonal coordinate systems and external regions, using
spherical and cylindrical coordinate systems.
For the each solution, it is shown the convergence of the
expression obtained for the longitudinal component of the
electric field.
Based on the developed method, a model of analysis is
elaborated to determine the field and the characteristics
impedance of coaxial cables of arbitrary cross section.
The model is applied to cables with circular and
rectangular sections.
The dyadic Green´s function method is finally applied to
the analysis of coaxial cables with internal metallic
struts periodicaly placed.
|
5 |
[en] ANALYSIS OF THE INSULATION OF AERIAL TRANSMISSION LINES SUBJECT TO VOLTAGE SURGES / [pt] ESTUDO DE ISOLAMENTO DE LINHAS AÉREAS DE TRANSMISSÃO SUBMETIDAS A SURTOS DE TENSÃOPAULO ALEXANDRE MACHADO 12 February 2008 (has links)
[pt] Vários aspectos de um sistema elétrico de potência devem
ser avaliados em detalhe antes de sua construção e
operação. A escolha dos níveis de isolamento utilizadas
é
editada pelas condições em regime permanente e de sobre
tensões que poderão ocorrer no sistema. Naturalmente, as
linhas de transmissão veículos de transporte de energia
estão intimamente ligadas a este problema. A sua
perfeita
operação determina níveis de atendimento apropriados aos
consumidores. Portanto, é de extrema importância que se
conheça o comportamento do isolamento do sistema de
transmissão. O presente trabalho tem por objetivo
fornecer
ao engenheiro condições d analisar a performance de uma
linha de transmissão quando submetida a surtos
atmosféricos e a surtos de manobra através de dois
programas desenvolvidos para o computador digital HP-
2100. / [en] Many aspects of an electric utility power system design
must be evaluated in detail prior to construction and
operation. The choice of insulation requirements on
eletric utility system equipment is dictated both by the
steady state conditions as well as by overvoltages which
can occur on the system. Transmission lines, which are the
way to carry energy, are certainly involved in this
problem. Therefore it is very important to know their
insulation behavior. The purpose of this work is to give
the engineer conditions to analyze transmission lines
behavior, by way of two digital programs, one concerning
lightining strokes and the other switching surges.
|
6 |
[en] METHODIZATION OF TRANSMISSION LINE FOUNDATION - STUDY AND DESIGN / [pt] METODIZAÇÃO DO ESTUDO DAS FUNDAÇÕES PARA SUPORTES DE LINHAS DE TRANSMISSÃOLILIANE TOJEIRA VELOZO 27 August 2010 (has links)
[pt] As fundações dos elementos de apoio de uma linha aérea de transmissão de
energia elétrica situam-se ao longo de extensos traçados, onde diferentes
condições de apoio para as estruturas são encontradas em razão da variação
natural dos horizontes. Tal configuração pode levar alternativamente a se
programarem estudos e sondagens especiais em cada local de suporte, fazendo
crescer os custos e prazos de projeto, ou ao contrário, reduzindo drasticamente a
investigação, com prejuízos evidentes ao planejamento, execução e economia da
obra de implantação da linha de transmissão. Dessa maneira, são organizados e
propostos procedimentos para avaliação do terreno segundo as suas orografia,
hidrografia, geologia e pedologia e do ambiente atmosférico local, cujas
manifestações são capazes de impor severas solicitações às torres e,
indiretamente, às fundações. É eleita a região da bacia do rio da Prata para
constituir o grande cenário do estudo, quer pela abundância de dados e
informações disponíveis sobre linhas de transmissão já em carga, ou ainda em
construção, nessa região. Assim sendo, desenvolve-se uma metodização para
orientar o estudo dessas fundações, considerando o conjunto torre x terreno x
fundação e buscando soluções técnicas convenientes e economicamente
aceitáveis, atendendo assim ao binário desempenho-custo. Para as torres são
considerados os modelos auto-suportados e estaiados, o terreno é variado entre
algumas categorias identificadas na região e as fundações são representadas pelas
superficiais, em sapatas, e pelas profundas do tipo tubulão. Buscando, ainda,
auxiliar no aprimoramento dos projetos de fundações para suportes de linhas de
transmissão, é desenvolvido um estudo de confiabilidade estrutural tendo como
modelo algumas das fundações pré-selecionadas para a metodização
primariamente desenvolvida. São determinadas as probabilidades de falha dessas
fundações através do programa FERUM e, a partir do levantamento dos prejuízos
financeiros causados pela falha desses elementos, determina-se o risco de falha.
Por último, é desenvolvido um estudo paramétrico para avaliar a influência do
projeto de fundação, do tipo de solo e da velocidade de vento sobre a
probabilidade de falha. / [en] The transmission line tower foundations are executed following extensive
paths, where different structural foundation conditions are found, in reason of
natural horizontal ground layer variations. Then, one may alternatively to
schedule and to execute special and specific studies or, conversely, to
substantially reduce the geothecnical investigation, with sensible economical loses
in the transmission line design and behavior. In such way, a methodology is
proposed to evaluate conveniently the site according to its geology, orography ,
hydrography and pedology as well to related atmospheric local manifestations,
able to submit severe mechanical solicitations to the towers and their foundations.
In this way, one proposes a methodology to govern the study of these foundations,
considering the tower x site x foundation relations and searching for convenient
technical and acceptable economical solutions. Guyed and self-supported models
are considered for towers, and the foundations are represented by footings, as the
superficial type, and piers, as the deep type. The rio do Prata basin is chosen to
constitute the large scenery of the study, because its abundant available data
concerned to already operational transmission lines, or still under design and
construction ones. Moreover, seeking the improvement of the tower foundation
design a study based on structural reliability is developed considering some
foundation models selected as mentioned above. Foundation failure probabilities
are determined by the FERUM computational program and the risk of failure is
obtained from economical damages caused by foundation failures. In the last, a
parametric study is developed to evaluate how does the failure probability behave
according to variations in the foundation soil, wind velocity and footing
dimensions and depth.
|
7 |
[en] NONLINEAR ELECTRICAL NETWORKS SIMULATION / [pt] SIMULAÇÃO DE REDES ELÉTRICAS CONTENDO NÃO-LINEARIDADESDENIS LAGE FERREIRA DA SILVA 21 October 2009 (has links)
[pt] As simulações de redes elétricas são atualmente fundamentais para o setor
elétrico. Uma de suas principais utilidades é permitir a análise de falhas e
ocorrências, que eventualmente passariam despercebidas. Existe atualmente, uma
grande variedade de algoritmos para realizar simulações de redes lineares, que
correspondem à grande maioria dos testes realizados em uma rede elétrica típica,
quando submetidos a situações usuais. Contudo, existem consumidores de grande
porte que possuem cargas não-lineares com uma grande influência na rede que a
alimenta. Sendo assim, torna-se necessário modelar esta carga não-linear para que
possa ser inserida no simulador da rede elétrica. Este trabalho propõe um método
para a formulação das equações de estado de redes não-lineares de forma
sistemática. A formulação do problema é, neste caso, parte fundamental da sua
solução, já que atualmente existem, comercialmente, algoritmos capazes de
resolver equações diferenciais não-lineares, como as que serão abordadas. Este
trabalho apresenta a simulação de uma rede elétrica contendo sub-redes lineares e
sub-redes não-lineares, utilizando um modelo de linhas de transmissão a
parâmetros distribuídos através de filtros digitais, permitindo a simulação da subrede
linear em taxas mais baixas. / [en] Electrical network simulations are currently very important to the electricity
sector. A major benefit from simulations is to permit a deeper insight into faulty
network situations, that otherwise could eventually pass unnoticed. Currently,
there are many algorithms that simulate linear networks, which comprise the
majority of the tests done in a typical network, when subject to normal situations.
However, there are large consumers, whose loads are nonlinear. These loads
represent large influences to their power feeding network. Thus, it becomes
necessary to model this nonlinear sub network so it can be inserted into the
electrical network simulator. The purpose of this work is to develop a formulation
approach for the nonlinear state equations that represents a nonlinear electrical
network. The formulation of the network is, in this case, an essential part of the
solution, since there are currently algorithms capable of solving nonlinear
differential equations, like the ones that will be studied in this work.
|
8 |
[en] TRANSMISSION LINE FAULT LOCATION NOT REQUIRING ZERO-SEQUENCE PARAMETERS / [pt] LOCALIZAÇÃO DE FALTA EM LINHAS DE TRANSMISSÃO, DESCONHECENDO-SE OS PARÂMETROS DE SEQUÊNCIA ZERO DA REDEHELIO ANTONIO DA SILVA 15 February 2006 (has links)
[pt] Os algoritmos para a localização de falta encontrados na
literatura são baseados em equações algébricas obtidas da
malha de falta [4], [16]. Para as faltas monofásicas, a
resistência de arco, a resistência de pé de torre e a
impedância de sequência zero da linha são incluídas. Essa
última impedância, por ser composta de uma soma entre as
impedâncias longitudinal e de retorno pela terra
(multiplicada por três), pode comprometer a precisão
desses algoritmos na indicação do local da falta, pois, a
resistividade do solo sob a linha varia frequentemente.
Dados reais [25] e de testes laboratoriais [50] têm
comprovado isso. Apesar da variação dessa resistividade,
nenhum dos algoritmos publicados na literatura questionou
a utilização dessa impedância no processo de localização
de falta. O objetivo deste trabalho é justamente propor um
novo algoritmo capaz de localizar qualquer falta, sem se
apoiar nos parâmetros de sequência zero da rede. A
principal contribuição deste trabalho está na utilização
somente dos circuitos de sequência positiva e/ou negativa
para a localização de faltas em sistemas de potência. Por
não utilizar qualquer parâmetro de sequência zero, o novo
algoritmo aqui proposto é capaz de localizar falta, tanto
em linha de transmissão com subestações em derivação ao
longo de sua extensão quanto em linha sem essas
subestações em derivação. Na primeira, a localização de
falta não foi contemplada por qualquer algoritmos
publicados na literatura, pois, esses tinham como
objetivo, o atendimento somente às linhas sem subestações
em derivação ao longo de sua extensão. Por isso, além do
ineditismo na forma de localização, este novo algoritmo é
aplicável à qualquer configuração de linha, o que
representa uma contribuição adicional deste trabalho. Esse
novo processo visa a localização de falta em sistemas
elétricos, mesmo os fortemente malhados. Por isso,
constitui o embrião de uma possível e provável nova
filosofia de proteção para relés de distância. / [en] Present fault location algorithms are based on algebraic
equations derived from the faulty network [4], [16]. Their
common characteristic is to use zero-sequence description
to apply Kichoff`s Laws. As a result, the are resistance,
the tower footing resistance and the zero-sequence
impedance of the line are included in the overall system
of equations, describing the network. This last impedance,
composed by the longitudinal and by the ground retum
impedances scaled by three, frequently compromises the
these algorithms accuracy. The reason is the underline
ground resistance fluctuation with temperature, rain, etc.
a very annoying fact, particularly in understudied remote
tropical regions, a common situation in Brazil.
In spite of the noticed ground-resistance variations, none
of the algorithms published in specific literature has
questioned the use of this impedance in the fault location
producedures.
The aim of this work is to propose a new algorithm capable
to locate any fault, requiring no support of the network
zero-sequence parameters and/or negative-sequence circuit
network models.
Avoiding the of zero-sequence parameters permits the new
fault location algorithm to be applied not only to
isolated transmission lines, but to a variety of network
topologies, including transmission lines tapped by local
distribution substations, a completely new result.
The proposed algorithm not only is less sensitive to local
physical conditions, but may be applied to complex
transmission line configurations, which represents an
additional contribution of this work. The new process
includes fault location for transmission lines embeded in
extremely meshed power networks it, therefore, constitutes
the beginning of a new of distance relay protection
philosophy.
|
9 |
[en] EXPANSION OF THE PEAK CAPACITY OF AN INTERCONNECTED HYDROELECTRIC GENERATING SYSTEM / [pt] PLANEJAMENTO DA EXPANSÃO DA CAPACIDADE DE PONTA DE UM SISTEMA HIDRO-ELÉTRICOCRISTINA MARIA DE ANDRADE LEOPOLDINO 16 November 2006 (has links)
[pt] Descreve-se uma metodologia para planejamento da expansão
da capacidade de ponta em sistemas interligados de usinas
hidroelétricas. O objetivo é determinar os geradores e
linhas de transmissão a serem instalados no sistema
existente, de forma a suprir a carga prevista da maneira
mais econômica possível, satisfazendo restrições de
confiabilidade. A solução é baseada no método de
decomposição de Benders, sendo o problema mestre um
problema de programação inteira e o subproblema um
problema estocástico de fluxo em redes. / [en] This thesis describes a methodology for peak capacity
expansion of interconnected hydroelectric generating
systems. The objective is to minimize investments in
generators and transmission lines, subject to contraints on
supply reliability. The solution approach is based on
Benders decomposition, in which the master problem is an
integer programming problem and the subploblem is a
stochastic network flow problem.
|
10 |
[en] ANALYSIS OF PROPAGATION OF SHORT ELECTRICAL PULSE BY THE SPECTRAL DOMAIN APPROACH / [pt] ANÁLISE DA PROPAGAÇÃO DE PULSOS ELÉTRICOS CURTOS EM LINHAS DE TRANSMISSÃO IMPRESSAS PELA ABORDAGEM DE DOMÍNIO ESPECTRALRICARDO ALBERTO OLIVARES VELIZ 02 August 2006 (has links)
[pt] Neste trabalho se estuda a propagação de pulsos elétricos
curtos em linhas de transmissão impressas, uniformes e não-
uniformes, através de simulação por computador. Como a
faixa de freqüências associada a estes pulsos, com duração
e picossegundos, extende-se até várias centenas de giga
Hertz, a caracterização das linhas de transmissão ao
longo das quais os pulsos se propagam exige o rigor dos
métodos de onda completa. Com este propósito é utilizada a
Abordagem de Domínio Espectral (ADE) para rigorosamente
considerar as características dos materiais e a geometria
das linhas, na faixa de freqüência requerida, no cálculo
das constantes de fase e de atenuação. A resposta a
transientes é analisada no domínio do tempo empregando-se
a Transformada de Fourier. É observado que a principal
causa da distorção dos pulsos é a característica
dispersiva das linhas; enquanto as perdas, devido aos
materiais ou pelo descasamento de impedância no caso de
linhas não-uniformes, só atenuam os sinais, sem deformá-
los significativamente. Isto foi observado em linhas
microstrips isoladas. Entretanto, em linhas microstrips
acopladas um outro mecanismo de distorção que se agrega,
e que é o dominante, é a distorção por acoplamento modal.
É comprovado também, que a natureza dispersiva das linhas
de transmissão pode ser usada, favoravelmente, para
reformar pulsos assimétricos. Este último resultado
encontra interessantes aplicações em Óptica. / [en] In this work, the propagation of short electrical pulse on
uniform and non-uniform planar transmission lines is
studied by means of computer simulation. As the frequency
band associated with electrical pulses with duration of
pico-seconds extends up to several hundreds of giga Hertz,
the characterization of the transmission lines along
which the pulses propagate requires full waves methods.
With this purpose the Spectral Domain Approach (SDA) is
used to rigorously consider the effects of the line
material and geometry, in the frequency band required, to
calculate the phase and attenuation constants. A Fourier
Transform is used to analyse the transient response in the
time domain. It is observed that the tranmission line
dispersion is the main cause for distortion fo the pulses,
while the losses - due to the materials or mismatching on
non-uniform lines - are mainly responsible for signal
attenuation. However, in coupled microstrip lines,
distortion due to mode coupling was the dominant
distortion mechanism. It is also observed that the
dispersive nature of the transmission line can be used
with advantage, through carefull choice of geometry and
composition, to reshape asymetrical pulses. The results fo
this study find applications on quasi-optical circuits and
optical circuits short pulse generation.
|
Page generated in 0.0487 seconds