• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] STATIC AND DYNAMIC SIMULATION OF VOLTAGE CONTROL BY GENERATOR AND SYNCHRONOUS COMPENSATOR / [pt] SIMULAÇÃO ESTÁTICA E DINÂMICA DO CONTROLE DE TENSÃO POR GERADOR E COMPENSADOR SÍNCRONO

ARMANDO GONCALVES LEITE 17 October 2008 (has links)
[pt] O tema abordado neste trabalho é a observação e análise, em regime permanente e dinâmico, da ocorrência de um fenômeno que já foi observado em condições reais de operação do sistema elétrico brasileiro, que é a relação oposta entre a tensão de excitação de geradores e compensadores síncronos e a tensão controlada. Nessas situações, a capacidade nominal de um gerador / compensador síncrono, por exemplo, não seria útil para manter a tensão controlada. Em virtude da relação oposta, um aumento na excitação da máquina abaixaria a tensão controlada. O controle automático continuaria agindo, abaixando ainda mais a tensão. Este mecanismo pode levar o sistema ao colapso. A abordagem do problema baseou-se na verificação do comportamento do gerador / compensador como dispositivo de controle de tensão, em regime permanente e dinâmico, ante as diversas situações normais de um sistema elétrico, tais como variações do valor da tensão de referência (tensão controlada) e de carga. A análise em regime permanente utilizou um algoritmo de fluxo de carga, enquanto a análise em regime dinâmico utilizou a simulação no domínio do tempo. A real existência do fenômeno foi comprovada através de várias destas análises, mostrando inclusive a mudança da região de operação em algumas delas. Em outros casos, os resultados da análise em regime permanente não coincidiram com os da análise em regime dinâmico. / [en] The aim of this work is to investigate, in steady state and dynamic performance, the phenomenon of the opposite relationship, already observed at real operation conditions of the Brazilian Electric System, between generators and synchronous compensators excitation voltage and the controlled one. In these situations, the generator / synchronous compensator nominal capacity, for example, would not be useful to keep the voltage controlled. Due the opposite relationship, an increase in the excitation voltage would reduce the controlled voltage. The automatic control would keep acting and reducing more the voltage. This mechanism can lead the system to the collapse. The study of this problem was based in the generator / compensator behavior as a control voltage device, in steady- state and dynamic performance, front of several operation situations of electric power system, like reference voltage (controlled voltage) variation and load changing. The steady state analysis used a load flow algorithm, while the time domain simulation was utilized for the dynamic performance analysis. The real existence of the phenomenon was verified through these analyses, emphasizing the operation region changing in some of them. In other cases, the analyses results in the steady-state were different of the dynamic performance results.
2

[en] PROJECT AND SIMULATION OF A TEST BENCH FOR STEADY-STATE OPERATION OF A REFRIGERATION SYSTEM / [pt] PROPOSTA E SIMULAÇÃO DE UMA BANCADA DE TESTES DE UM SISTEMA DE REFRIGERAÇÃO OPERANDO EM REGIME PERMANENTE

CARLOS MARX DA SILVA DE CARVALHO 03 June 2014 (has links)
[pt] O presente trabalho trata do projeto, modelagem e simulação de uma bancada de testes, com a finalidade de mensurar o desempenho de componentes de refrigeração, para ciclos por compressão de vapor. A configuração da bancada foi concebida para oferecer flexibilidade na escolha dos componentes e estabilidade durante a realização dos experimentos. Um modelo matemático foi desenvolvido e implementado a partir da aplicação dos princípios de conservação da massa e energia para cada um dos volumes de controle dos componentes da bancada. A modelagem considera também as equações de troca de calor, propriedades termodinâmicas e modelos físicos dos componentes, para prever condições de operação da bancada operando em regime permanente. Para a modelagem computacional utilizou-se o software EES-Engineering Equation Solver. O modelo resultante também foi utilizado no pré-dimensionamento dos subsistemas da bancada e na simulação de parâmetros característicos, a fim de delimitar a faixa de capacidades, bem como as variáveis de entrada e saída, necessárias ao controle do sistema. O dimensionamento e a seleção dos equipamentos e componentes foram efetuados com base no refrigerante R134a, como fluido de trabalho. No entanto, o modelo é compatível com a utilização de outros refrigerantes, tais como o R22, R407C, R410A, e outras misturas. O trabalho inclui um modelo para simular o comportamento em regime transiente do tanque inercial térmico com o intuito de estudar a estabilidade e o controle do sistema em regime permanente. A simulação demonstrou que a configuração da bancada garantirá estabilidade e reprodutibilidade dos experimentos nas eventuais variações das condições externas, diferindo, portanto, de grande parte dos sistemas de refrigeração convencionais. / [en] The present work deals with the design, modeling and simulation of a test bench used in evaluating the performance of components of vapor compression refrigeration systems. The mathematical model was developed and implemented based on the application of the conservation of mass and energy principles to each of the control volumes, heat transfer equations, thermodynamic properties for refrigerant and water and existing physical models for the system components were also applied. The software EES-Engineering Equation Solver was used as the computational platform. The resulting simulation program was initially used to size the test bench subsystems and to simulate characteristic parameters in order to determine the range of capacities and input and output variables. Refrigerant R-134a was the working substance considered when sizing and choosing system components, but the model can also be used with R22 refrigerants as well as R410A, R407C and others refrigerant mixtures. The work also includes a transient analysis of the thermal inertial tank with focus on the study of the operational control for the system being operated at steady state. The simulation showed that the layout of the test bench will warrant stability and reproducibility of experiments for eventual changes in the external condition, thus differing from typical conventional vapor compression refrigeration systems.
3

[en] STATIC AND DYNAMIC SIMULATION FOR GENERATOR VOLTAGE CONTROL / [pt] SIMULAÇÃO ESTÁTICA E DINÂMICA DO CONTROLE DE TENSÃO POR GERADORES

LUIS FERNANDO FERREIRA 09 January 2007 (has links)
[pt] O problema tratado nesta dissertação é a relação oposta entre a tensão de excitação de geradores e compensadores síncronos e a tensão controlada, quando o sistema de transmissão da área encontra-se muito carregado. Neste caso, a capacidade nominal de um gerador / compensador não seria útil para manter a tensão controlada. Devido à relação oposta, uma maior excitação da máquina iria abaixar a tensão controlada. O controle automático iria continuar agindo, abaixando ainda mais a tensão. Este mecanismo pode levar o sistema ao colapso e foi verificado em ponto de operação real do sistema brasileiro. Esse fenômeno ocorre quando a injeção de potência na rede de transmissão ou distribuição é elevada. Com o advento da geração distribuída, co-geração e produtores independentes, usualmente conectados à rede existente em níveis de tensão mais baixas, têm-se observado ocorrências do fenômeno. O objetivo do trabalho é então entender melhor as situações operativas reais que levam à ocorrência do fenômeno, principalmente quando existem vários equipamentos de controle de tensão ao redor do gerador em análise. A abordagem do problema baseou-se na verificação do comportamento do gerador / compensador como dispositivo de controle de tensão, no domínio do tempo e em regime permanente. Avaliaram-se as ações de controle do mesmo a partir de sete tipos de análise distintas para pontos de operação na região normal e anormal da curva SV. A real existência do fenômeno foi comprovada através de algumas destas análises. Porém, conclui-se que nem todas as formas de análise no domínio do tempo fazem uma avaliação completa do fenômeno. Dentre essas, estão a análise dinâmica agregada e a análise dinâmica agregada sob influência dos equipamentos de controle de tensão, que para pontos de operação na região anormal da curva SV não responderam em concordância com os outros tipos de análise. / [en] The problem addressed in this research is the opposite relationship between the , synchronous generator / compensator excitation voltage and the controlled voltage when nearby network is heavily loaded. In this situation, the nominal capacity of a generator / compensator would not keep the voltage controlled. Due to the opposite relationship, the higher the excitation voltage the lower is the controlled voltage. So, the automatic control would continue acting lowering the voltage. This mechanism, verified in a real operational point of the Brazilian Electric System, can lead the system to collapse. This phenomenon occurs when the power injection into the network is high. It is prone to occur in the new scenario of distributed generation connected to already existing low voltage networks. The objective of this work is to understand the actual operative situations that lead to the occurrence of the phenomenon, mainly when there are several voltage control devices nearby the generator. The analysis of the problem was based on the verification of the generator behaviour as a voltage control device, in time domain simulation and in steady state. The control actions were evaluated from seven different ways for operating points in the normal and the abnormal region of the SV curve. The actual existence of the phenomenon was proven through some of these analyses. However, some of the time domain simulations did not evaluated the phenomenon completely. Among them, the aggregated dynamic analysis and the aggregated dynamic analysis under influence of other voltage control devices have not got the expected responses for the abnormal region of the SV curve, in comparison with other analysis.

Page generated in 0.0565 seconds