[en] AUTOCALIBRATION OF FREQUENCY STANDARDS USING THE INTERNET / [es] CALIBRACIÓN AUTOMÁTICA DE PADRONES DE TIEMPO Y FRECUENCIA VÍA INTERNET / [pt] CALIBRAÇÃO AUTOMÁTICA DE PADRÕES ATÔMICOS DE TEMPO E FREQÜÊNCIA VIA INTERNET

DALTON VILELA CAMILHER 10 October 2001 (has links)
[pt] A calibração de padrões atômicos de tempo e freqüência, na forma atualmente realizada, apresenta o inconveniente de ter que se fazer o transporte do Padrão de Transferência até os laboratórios onde se encontram os padrões a serem calibrados. Isto se dá pelo fato destes laboratórios não possuírem uma maneira adequada para enviarem seus padrões ao Departamento do Serviço da Hora do Observatório Nacional (DSH/ON), órgão responsável perante o INMETRO na calibração em tempo e freqüência e detentor do Padrão Nacional. Propõe- se aqui a substituição do procedimento atual por um sistema de calibração automática via Internet, o que elimina a necessidade do deslocamento do Padrão de Transferência. Neste novo sistema de calibração, a referência passa a ser um receptor de GPS (Global Position Sistem), que assume o papel de Padrão de Transferência, ao qual o padrão a ser calibrado é ininterruptamente comparado. O acesso e armazenamento dos dados pelo DSH/ON é feito por meio de um programa que controla remotamente a calibração no laboratório via conexão pela Internet. O presente trabalho envolve uma comparação entre o sistema atual e o proposto aqui, todo o desenvolvimento e apresentação do programa computacional, a montagem de um sistema completo de simulação prática, inclusive com acesso remoto via Internet, a coleta e tratamento dos dados e a apresentação do procedimento utilizado para se chegar à incerteza de medição do sistema. Procura-se ressaltar a vantagem de um sistema de calibração automático, quanto à coleta dos dados, assim como a não dependência do transporte do Padrão de Transferência para a realização da calibração, evitando- se com isto a sua deterioração . Na conclusão deste trabalho a incerteza obtida é comparada com a do procedimento atualmente em prática e a partir desta comparação são feitas considerações quanto à implementação do novo sistema e ao uso do r eceptor de GPS como Padrão de Transferência. / [en] The time and frequency calibration of atomic standards presents the inconvenience of the need of transportation of the Transfer Standard to the laboratories in which stay the standards to be calibrate. This happens because the laboratories do not possess a way to send its standards to the Departamento do Serviço da Hora do Observatório Nacional (DSH/ON), organ representative of INMETRO in Time and Frequency calibrations and detainer of the National Standard. This work intends the substitution of the procedure adopted today by a system of automatic calibration using Internet, eliminating the need of the displacement of the Transfer Standard. In this new procedure, the reference is t he Global Position Sistem (GPS) receiver, assuming the role of the Transfer Standard, to which the standard to be calibrate is compared continuosly. The access and storage of the data for the DSH/ON are made by means of a computer code that remotely controls the calibration through an Internet connection. The present work involves a comparison among both systems, the whole development and presentation of the computer code, the assembling of a complete system of practical simulation, the acquisition and data treatment and the presentation of the procedure used to obtain the measurement of the uncertainty. The advantage of an automatic calibration system, as well as of the collection of the data, is the fact that it not depending of the transportation of the Reference Standard for the accomplishment of the calibratio. As a conclusion of this work the obtained uncertainty is compared with the one in use today and based in this comparison we made considerations about the implementation of the new system and the use of the GPS receiver as Transfer Standard. / [es] La calibración de padrones atómicos de tiempo y frecuencia, en la forma actualmente realizada, tiene el inconveniente de tener que realizar el transporte del Padrón de Transferencia hasta los laboratorios donde se encuentran los padrones que serán calibrados. Esto se debe al hecho de que estos laboratorios no poseen una manera adecuada para enviar sus padrones al Departamento de Servicio de la Hora del Observatorio Nacional (DSH/ON), óprgano responsable frente al INMETRO en la calibración en tiempo y frecuencia y detentor del Padrón Nacional. Se propone aqui la substituición del procedimiento actual por un sistema de calibración automática vía Internet, que elimina la necesidad del desplazamiento del Padrón de transferencia. En este nuevo sistema de calibración, la referencia pasa a ser un receptor de GPS (Global Position Sistem), que asume el papel de Padrón de Transferencia, al cual el padrón a ser calibrado es ininterruptamente comparado. El acceso y almacenamiento de los datos por el DSH/ON se realiza a través de un programa que controla remotamente la calibración en el laboratorio vía conexión por Internet. El presente trabajo compara el sistema actual con el aqui propuesto, todo el desarrollo y presenta el programa computacional, el montaje de un sistema completo de simulación práctica, incluso con acceso remoto víaa Internet, la recolección y tratamiento de datos y la presentación del procedimiento utilizado para llegar a los erros de medición del sistema. Se resalta la ventaja de un sistema de calibración automático, así como la no dependencia del transporte del Padrón de Transferencia para la realización de la calibración, evitando con esto su deterioración. En la conclusión de este trabajo se compara el error obtenido con el del procedimiento actualmente en práctica y a partir de esta comparación se realizan consideraciones respecto a la implementación del nuevo sistema y al uso del receptor de GPS como Padrón de Transferencia.

Page generated in 0.039 seconds