Spelling suggestions: "subject:"água – estações dde tratamento"" "subject:"água – estações dee tratamento""
1 |
Estudo do adensamento e desidratação dos resíduos gerados na ETA-Brasília / Thickening and dewatering of residues produced at the Brasília water treatment plantGuimarães, Gustavo Costa 07 1900 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2007. / Submitted by Luis Felipe Souza (luis_felas@globo.com) on 2009-01-07T12:14:46Z
No. of bitstreams: 1
Dissertacao_2007_GustavoGuimaraes.pdf: 4183016 bytes, checksum: 7c61ae67e75c158534feef02df523212 (MD5) / Approved for entry into archive by Georgia Fernandes(georgia@bce.unb.br) on 2009-02-27T15:39:08Z (GMT) No. of bitstreams: 1
Dissertacao_2007_GustavoGuimaraes.pdf: 4183016 bytes, checksum: 7c61ae67e75c158534feef02df523212 (MD5) / Made available in DSpace on 2009-02-27T15:39:08Z (GMT). No. of bitstreams: 1
Dissertacao_2007_GustavoGuimaraes.pdf: 4183016 bytes, checksum: 7c61ae67e75c158534feef02df523212 (MD5) / O presente trabalho enfoca o adensamento e desidratação dos resíduos da ETA-Brasília,
importante unidade operacional do sistema de abastecimento de água do Distrito Federal. A
ETA-Brasília está passando por intervenções de reforma e ampliação, e estudos anteriores
indicaram que o tratamento dos resíduos proposto para essa estação que inclui a desidratação por centrífuga, provavelmente apresentará resultados inferiores aos indicados no projeto, em termos de concentração de sólidos na torta. Como conseqüência, a ETA-Brasília apresentará
maiores custos operacionais para desidratação dos resíduos produzidos e para transporte da torta gerada, além de eventuais problemas ambientais associados à alternativa selecionada para destinação final.
Duas hipóteses foram levantadas para explicar a baixa desidratabilidade observada na desidratação por centrífuga, e são objeto de avaliação desse trabalho. A primeira seria a influência da presença de algas na água bruta, que emprestam características orgânicas ao lodo. A outra hipótese é relacionada à possibilidade dos lodos flotados reterem parte das microbolhas da flotação em sua estrutura, dificultando a etapa de desidratação. Dessa forma, a metodologia experimental do presente trabalho permitiu comparar a desidratação entre lodos produzidos pelo adensamento da água de lavagem da ETA-Brasília, por flotação e sedimentação, com o de outra estação de tratamento de água (ETA-Descoberto), abastecida por manancial com água bruta de diferentes características. Os experimentos de adensamento foram realizados em instalação piloto, localizada na ETA-Brasília, e os de desidratação, tanto
por centrifugação quanto por filtração forçada, em escala de bancada. Os resultados obtidos mostraram não haver influência importante do processo de adensamento na desidratabilidade dos lodos de ETAs, sugerindo que a incorporação de microbolhas de ar ao lodo não é o fator que determina a baixa eficiência da centrifugação. Em relação à influência das características da água bruta, verificou-se que a água bruta que alimenta a ETA-Brasília, de caráter orgânico devido à presença de algas, produziu resíduos no tratamento de água também com características orgânicas, e essas características foram determinantes na desidratabilidade dos lodos, levando a teores de sólidos na torta da ordem de 10%, bastante inferiores aos obtidos a partir dos resíduos da ETA-Descoberto, freqüentemente acima de 30%. A avaliação
preliminar utilizando a técnica de descongelamento e descongelamento indicou que a baixa desidratabilidade dos resíduos da ETA-Brasília pode estar relacionada à distribuição de água na estrutura interna do floco, que é determinada nos primeiros estágios do tratamento de água bruta, recomendando-se estudar a coagulação e floculação como forma de se obter lodos com
melhores características de desidratabilidade. _______________________________________________________________________________ ABSTRACT / The present work focuses the thickening and dewatering of residues from the Brasilia Water Treatment Plant (WTP), an important operational unit of the water supply system in the Federal District, Brazil. Brasília WTP is enlarging and undergoing improvements, and
previous studies have indicated that the treatment of the residues which includes centrifuge dewatering, will present inferior results to those indicated in the project, in terms of cake solid content. As a consequence, Brasília WTP will have greater operational costs for dewatering of the produced residues and the transport of the generated cake, beyond the eventual
environmental problems associated with the alternative final disposal. Two hypotheses were raised to explain the low dewaterability observed in the centrifugal dewatering, and are objectives of evaluation in this work. The first one is the presence of algae in raw water, which gives the sludge organic characteristics. The second hypothesis is related to the possibility of sludge retaining part of the micro-bubbles in its structure, hampering the dewatering phase and resulting in a cake with a low solids content. The experimental methodology of the present work compared the centrifugal dewatering between flotation and sedimentation thickened sludge, using backwash water from Brasilia WTP, with another WTP plant (Descoberto WTP), supplied by reservoir with different raw water characteristics.
Thickening experiments were carried out in a pilot plant located at Brasilia WTP. Dewatering
tests were carried in a bench scale, as much for centrifugation as for press filters. The results obtained in the present work showed that there was no important difference in the
thickening process in sludge WTP, suggesting that the incorporation of micro-bubbles of air in the sludge is not the factor that determines the low efficiency of centrifuge dewatering. In relation to the influence of the raw water characteristics, it was verified that the raw water that supplies Brasilia WTP, with an organic character due to algal presence, also produced residues
in the water treatment with organic characteristics, and these characteristics were determinative in the sludge dewatering, leading to a cake solids content in the order of 10%, very inferior to those obtained from the residues of Descoberto WTP, frequently above 30%. The preliminary evaluation using the freeze-thaw technique indicated that the low dewaterability of the residues of Brasilia WTP can be related to the water distribution in the internal structure of the floc, that is determined in the initial steps of raw water treatment, and further studies in the coagulation and flocculation as form of getting sludges with better dewaterability characteristics are recommended.
|
2 |
Desenvolvimento e aplicação de sistema de floco-flotação por ar dissolvido para tratamento da água de lavagem do filtro da ETA Gavião / Development and application system of flake-dissolved air flotation for treating wash water filterChaves, Karina Oliveira January 2012 (has links)
CHAVES, K. O. Desenvolvimento e aplicação de sistema de floco-flotação por ar dissolvido para tratamento da água de lavagem do filtro da ETA Gavião. 2012. 125 f. Dissertação (Mestrado em Engenharia Civil) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2012. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2012-09-13T17:27:18Z
No. of bitstreams: 1
2012_dis_kochaves.pdf: 3780564 bytes, checksum: c01f7a9b02759238448368189535643a (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2012-09-25T14:04:58Z (GMT) No. of bitstreams: 1
2012_dis_kochaves.pdf: 3780564 bytes, checksum: c01f7a9b02759238448368189535643a (MD5) / Made available in DSpace on 2012-09-25T14:04:58Z (GMT). No. of bitstreams: 1
2012_dis_kochaves.pdf: 3780564 bytes, checksum: c01f7a9b02759238448368189535643a (MD5)
Previous issue date: 2012 / In Brazil the filter backwash wastewater is normally released in to the water resources without proper treatment, representing a potential danger to the environment. Thus, it is necessary to treat this wastewater in order to dispose it in accordance to federal and state environmental laws. Studies show that Dissolved Air Flotation (DAF) technology has been feasible for this purpose. It is believed that the incorporation of flocculation in curtains and air dissolved flotation system in the same unit can promote high efficiency and significant size reduction, which translates in a technological innovation: the Floculator - Dissolved Air Flotation (FFAD) unit. A FFAD pilot unit was built to evaluate the treatment of Gavião Water Treatment Plant filter backwash wastewater, owned by the Water and Wastewater Company of Ceará (CAGECE). This research had as main objective to quantify and verify the compliance of the filter backwash wastewater parameters to the Resolution No. 430/11 and 357/05 of CONAMA and Ordinance No. 154/2002 of SEMACE. Treatability studies were performed with filter backwash wastewater using Jartest to evaluate the influence of cationic polymer dosages and the feasibility of decreasing flocculation velocity gradients (35 to 5.6 s-1) in the FFAD. Experimental runs of the flocculation - flotation system were performed to evaluate the best polymer dosage and the process parameters such as recirculation rates (TR) and surface application rates (TAS). These parameters were compared by observing the lower residual turbidity and best removal efficiency in the clarified water (AC). The treated wastewater was again characterized using physicalchemical and bacteriological parameters and compared to the specific legislation. The results showed that the use of 1 mg.L-1 of polymer, recirculation rate of 15% and surface application rate of 57 m3.m-2.d-1, presented the highest turbidity efficiency removal (> 98%) and a very stable performance against sudden changes in the influent quality (94.4 to 410UT). It should be noted that the unity showed also a high average efficiency total coliforms removal (98.5%), apparent color removal (97.6%), DOC removal (92.6%), of aluminum (84.1%) removal and turbidity (99.2 %) removal. Given these results, it was concluded that the AC coming from the treatment of ALF by ETA WTP Gavião FFAD met the discharge parameters listed for water resources. / No cenário brasileiro, os resíduos de Estações de Tratamento de Água (ETAs) são normalmente lançados in natura em corpos hídricos, apresentando-se como potencialmente danosos ao meio ambiente, sendo necessário tratá-los para que sejam descartados conforme os aspectos legais. Estudos demonstram que a tecnologia da Flotação por Ar Dissolvido (FAD) tem sido viável para este fim. Acredita-se que a incorporação da floculação em cortinas numa mesma unidade de flotação possa promover elevada eficácia ao sistema, traduzindo-se como uma inovação tecnológica: o Floco-Flotador por Ar Dissolvido (FFAD). Uma unidade piloto de FFAD foi construída para o tratamento da água de lavagem dos filtros da ETA Gavião, pertencente à Companhia de Água e Esgoto do Ceará (CAGECE). Esta pesquisa teve como objetivo quantificar e verificar o atendimento da água de lavagem dos filtros (ALF) desta ETA e da água clarificada via FFAD aos padrões de lançamento de efluentes conforme as Resoluções nº 430/11 e 357/05 do CONAMA e Portaria nº 154/2002 da SEMACE. Estudos de tratabilidade da ALF em Jartest foram realizados para avaliar a influência da dosagem de polímeros catiônicos e a viabilidade de gradientes de velocidade decrescente (35 a 5,6 s-1) a serem empregados no equipamento de FFAD desenvolvido. Ensaios de flotação foram realizados a fim de avaliar a dosagem do polímero e os parâmetros de processo como taxas de recirculação (TR) e taxas de aplicação superficial (TAS). Após definidos estes parâmetros, ensaios de FFAD foram realizados em triplicata para coleta da AC a fim de compará-la com os principais padrões de lançamento de efluente em corpos hídricos classe II. Somente os parâmetros pH, Fluoreto, Amônia, E. coli e Sólidos dissolvidos da ALF atenderam aos padrões de lançamento. Ao aplicar polímero a 1 mg.L-1, taxa de recirculação de 15%, gradientes de velocidade decrescente (19,3 a 5,6 s-1), taxa de aplicação superficial de 57 m3.m-2.d-1 com tempo de detenção hidráulico de 22 minutos no FFAD, os resultados alcançaram elevada eficiência na remoção de turbidez (superior a 98%) mesmo enfrentando variações bruscas na qualidade da ALF (94,4 a 410 UT). Observou-se também significativa eficiência média na remoção de coliformes totais (98,5%), cor aparente (97,6%), DQO (92,6%) e remoção de alumínio (84,1%). Diante destes resultados, constatou-se que a ALF da ETA Gavião tratada via Floco-flotação por ar dissolvido atendeu aos referidos padrões de lançamento em corpos hídricos.
|
3 |
Aplicação dos ensaios Salmonella/microssoma e MTT para avaliação da mutagenicidade e citotoxicidade de águas submetidas à cloração e fotocatálise.Souza, Cássia Cabral e January 2014 (has links)
Programa de Pós-Graduação em Engenharia Ambiental. PROÁGUA, Pró-Reitoria de Pesquisa e Pós Graduação, Universidade Federal de Ouro Preto. / Submitted by Oliveira Flávia (flavia@sisbin.ufop.br) on 2014-10-15T20:21:10Z
No. of bitstreams: 2
license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5)
DISSERTACAO_AplicaçãoEnsaiosSalmonella.pdf: 1814909 bytes, checksum: 7086c2b9cbdfa484976fc4501ff4fd42 (MD5) / Approved for entry into archive by Gracilene Carvalho (gracilene@sisbin.ufop.br) on 2014-11-04T16:50:26Z (GMT) No. of bitstreams: 2
license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5)
DISSERTACAO_AplicaçãoEnsaiosSalmonella.pdf: 1814909 bytes, checksum: 7086c2b9cbdfa484976fc4501ff4fd42 (MD5) / Made available in DSpace on 2014-11-04T16:50:26Z (GMT). No. of bitstreams: 2
license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5)
DISSERTACAO_AplicaçãoEnsaiosSalmonella.pdf: 1814909 bytes, checksum: 7086c2b9cbdfa484976fc4501ff4fd42 (MD5)
Previous issue date: 2014 / Diversas classes de fármacos têm sido detectadas no ambiente em baixas concentrações (ng/L a μg/L), e mais recentemente em amostras de água tratada. A maioria das ETAs no Brasil opera com tratamento convencional da água sem a implantação de etapas específicas para a remoção de microcontaminantes. Quando fármacos entram em contato com o cloro, como o hipoclorito de sódio, na desinfecção podem ser oxidados e transformados em subprodutos com estrutura química e potencial tóxico algumas vezes desconhecidos. Os Processos Oxidativos Avançados (POA) como a fotocatálise com TiO2/UV-C têm sido pesquisados como alternativa à cloração para aumentar a eficiência de remoção de tais compostos. Neste trabalho foi padronizada e implementada a técnica Salmonella/microssoma (teste de Ames) para avaliação da mutagenicidade e aplicado o ensaio colorimétrico do MTT em células HepG2 para verificar a citotoxicidade dos fármacos captopril (CPT), diclofenaco (DCF) e sulfametoxazol (SMX) e dos seus possíveis subprodutos formados após cloração e fotocatálise com TiO2/UV-C. As concentrações dos fármacos testadas foram 1, 0,75, 0,50, 0,25 e 0,01 mg/L e os tempos de contato de 5 e 30 min para a cloração e 120 min para a fotocatálise. A dose de cloro foi 1mg/L para o DCF e SMX e para o CPT 10 mg/L. A concentração de TiO2 foi 120 mg/L. Os resultados do ensaio de mutagenicidade foram avaliados adotando três variáveis para interpretação dos dados (ANOVA, relação dose-resposta e razão de mutagenicidade). Com base nestas variáveis, os três fármacos e suas amostras cloradas e após fotocatálise não induziram mutações do tipo deslocamento do quadro de leitura e substituição dos pares de base nas cepas TA98 e TA100 da bactéria S. typhimurium com (+S9) e sem (-S9) metabolização (mistura S9) nas doses testadas. Estes resultados estão de acordo com os dos testes de viabilidade celular por MTT em que os tratamentos da água com cloro e TiO2/UV-C não causaram efeito tóxico para os fármacos CPT e DCF. Após o tratamento da água com estes fármacos observou-se um aumento da viabilidade celular sugerindo que ambos não induzem ação tóxica às células nas doses investigadas (0,8, 20, 40, 60, 80 ng/poço). Os resultados da citotoxicidade do SMX foram inconclusivos uma vez que apenas a dose intermediária (40 ng/poço) mostrou diminuição da viabilidade celular, o que indicaria um possível efeito tóxico após o tratamento com cloro. ________________________________________________________________________ / ABSTRACT: Several classes of drugs have been detected in the environment at low concentrations (ng/L a μg/L), and more recently in samples of treated water. Most Brazilian Water Treatment Plant (WTP) operates with conventional water treatment without the deployment of specific steps for removing microcontaminants. When drugs come into contact with chlorine as sodium hypochlorite for disinfection, they can be oxidized and transformed into products wich sometimes have unknown structure and toxic potential. The Advanced Oxidative Processes (AOP) as TiO2/UV-C photocatalysis have been tested by different research groups to increase the efficiency of removal of such compounds. For this work was standardized and implemented Salmonella / microsome assay (Ames test) for evaluation of mutagenicity and applied the MTT colorimetric assay in HepG2 cells to verify the cytotoxicity of drugs captopril (CPT), diclofenac (DCF) and sulfamethoxazole (SMX) and the possible products formed after chlorination and photocatalysis with TiO2/UV-C. The concentrations of the drugs tested were 1, 0,75, 0,50, 0,25 and 0,01 mg/L and contact time 5 and 30 min for chlorination and 120 min for photocatalysis. The dosage of chlorine was 1mg/L for DCF and SMX and for CPT was 10 mg/L. The concentration of TiO2 was 120 mg/L. The results of the mutagenicity test were evaluated taking three variables for the interpretation of the data (ANOVA, dose-response relationship and mutagenicity ratio). Based on this approach, drugs and their chlorinated samples and after photocatalysis did not induce frameshift and base-pair substitution mutations in TA98 and TA100 strains of S. typhimurium bacteria with (+S9) and without (-S9) metabolic activation system (mix S9) at the doses tested. These results are in agreement with tests of cell viability by MTT in the treatment of water with chlorine and TiO2/UV-C did not cause toxic effects to the cells for CPT and DCF drugs. After the water treatment with these drugs it was observed an increase in cell viability suggesting that both contaminant do not induce toxic effect to the cells at the doses investigated (0,8, 20, 40, 60, 80 ng/well). The results of the cytotoxicity of SMX were not conclusive since only the intermediate dose (40 ng/well) showed a decreased cell viability, which would indicate a possible toxic effect after treatment with chlorine.
|
4 |
Avaliação em escala piloto do uso de membrana de osmose reversa para tratamento de água para uso industrialWosniak, Alcely Jose 27 February 2018 (has links)
Orientador : Profª. Drª. Daniela Neuffer / Co-orientador : Profª. Drª. Karen Juliana do Amaral / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Mestrado Profissional em Meio Ambiente Urbano e Industrial, em parceria com o Serviço Nacional de Aprendizagem Industrial e a Universität Stuttgart. Defesa: Curitiba, 24/11/2015 / Inclui referências: f. 96-109 / Resumo: A utilização de rios degradados deve ser visto como uma alternativa viável para aumento da disponibilidade de água aos diversos usos, inclusive para fins industriais. A água a ser utilizada na indústria requer muitas vezes qualidade superior àquela destinada ao consumo humano. Com base nas exigências de qualidade e no conhecimento dos processos existentes, é possível obter água com qualidade adequada ao uso industrial a que se destina. Curitiba e a Região Metropolitana (RMC) apresentam um alto grau de industrialização e um conflito de uso de água potável para fins industriais. A Estação de Tratamento de Água Industrial Araucária (ETAIA) é uma estação de tratamento de água para reúso indireto e não potável. Atualmente, a ETAIA é composta pelos processos de oxidação, coagulação, decantação e filtração, resultando numa qualidade da água tratada fora dos padrões estabelecidos pelas indústrias que a utilizam. Desta forma, este trabalho tem como objetivo geral avaliar a operação de uma planta de osmose reversa (OR) em escala piloto para póstratamento da água produzida na ETAIA, tendo em vista a qualidade final do permeado e a mistura com a água produzida na estação. Para o estudo, foram avaliadas a qualidade do filtrado de um filtro de carvão ativado granular (GAC) e a qualidade do permeado da OR. Para verificar o desempenho da OR, foram analisados os parâmetros no permeado: turbidez, condutividade, detergente sintético não biodegradável (Alquio Benzeno Sulfanato de Sódio - ABS), cloretos, fluoretos, manganês, ferro, fosfato, sulfatos, dureza, nitrogênio amoniacal, carbono orgânico total (TOC), e sílica. Também houve a avaliação da retenção, rejeição e taxa de permeabilidade da OR para dois tipos de membranas ESPA 1 - 4040 e ESPA 2 LD - 4040. Os resultados demonstraram que filtro de GAC removeu 100% do cloro residual, e que a membrana ESPA 1 - 4040 apresentou um fluxo de permeado 32,4 L/(m² h) ou 63,5% do fluxo padrão e uma retenção salina 97,65%. A membrana ESPA 2 LD - 4040 apresentou um fluxo 32,8 L/(m² h) ou 77,3% do fluxo padrão e uma retenção salina 97,79%. Houve a necessidade de três lavagens químicas na membrana, devido à colmatação de origem orgânica. Essas lavagens foram agressivas, reduzindo a vida útil da membrana. Em comparação com a água produzida na ETAIA, a água gerada na OR apresentou uma melhor qualidade, atendendo a todos requisitos de qualidade dos clientes. O custo da água produzida no sistema de OR foi 153% maior que o custo da água produzida na ETAIA. A água produzida na ETAIA não é apropriada para alimentação de um equipamento de OR nem para atendimento as industrias. A membranas ESPA 2 LD - 4040 apresentou melhor resultados de qualidade e desempenho. A aplicação da OR para o tratamento da água produzida pela ETAIA se mostrou eficaz, produzindo um permeado com a qualidade dentro dos padrões exigidos no contrato com as indústrias, podendo assim ser utilizada como pós-tratamento para água produzida na ETAIA. No entanto, a água de alimentação tratada na ETAIA não é apropriada para abastecer a OR, e que, caso seja operada em escala real, haverá prejuízo para o desempenho da OR ao longo do tempo de operação. Palavras-chave: Água industrial. Torre de resfriamento. Autópsia da membrana. / Abstract: The recovery of degraded water sources should be seen as a viable alternative to increase the availability of water for various uses, including for industrial purposes The water to be used in industry often requires superior to that intended for human consumption. Based on the quality requirements and knowledge of existing processes, it is possible to obtain water quality suitable for the industrial use to which it is intended. Curitiba and Metropolitan Region (RMC) have a high degree of industrialization and a conflict of use of drinking water for industrial purposes. Industrial Water Treatment Plant Araucaria (ETAIA) is a water treatment plant for reuse indirect and not drinkable. Currently, ETAIA is composed of the processes of oxidation, coagulation, sedimentation and filtration, resulting in treated water quality standards set out by the industries that use. Thus, this study is to evaluate the overall operation of the reverse osmosis (OR) for a post-treatment of water produced in ETAIA, considering the final quality of the permeate and mixing with the water produced at the station. For the study, we evaluated the quality of filtered of a granular activated carbon filter (GAC) and the quality of the OR permeate. To verify the performance of the RO, the concentrations of the turbidity parameters were analyzed, conductivity, non-biodegradable synthetic detergent (Alquio Benzene Sodium Sulfanato - ABS), chlorides, fluorides, manganese, iron, phosphate, sulphate, hardness, ammonia nitrogen, organic carbon total (TOC), and silica in the permeate, with an average removal observed 90%. There was also the retention evaluation, OR rejection and permeability rate for both types of membranes ESPA 1 - 4040 e ESPA 2 LD - 4040. The results showed that GAC filter removed 100% of residual chlorine and the membrane 1 ESPA - 4040 showed a permeate flow of 32.4 l / (m² h) or 63.5% of the standard flow and a saline retention 97.65%. The membrane 2 ESPA-4040 showed a LD flow 32.8 L / (m² h) or 77.3% of the standard flow and a saline retention 97.79% .There was the need for three chemical washes, due to clogging of the membrane organic origin. These washings were aggressive, reducing the life of the membrane. The cost of water produced by the RO system was 153% higher than the cost of water produced in ETAIA. The ESPA 2 membranes LD-4040 presented better results of quality and performance. The application of OR for the treatment of water produced by ETAIA proved effective, producing a permeated with the quality standards required in the contract with the industries, and thus can be used as posttreatment for produced water at ETAIA. However the feed water treated in ETAIA is not suitable for fuel OR, and that, if it is operated in real scale, there will be damage to the performance of OR over time. Keywords: Industrial water. Cooling tower. Membrane autopsy
|
5 |
Desempenho de estações de tratamento de águas cinzas e negras para residências rurais, envolvendo filtros orgânicos e reatores solares / Performance overview of grey and black water treatment plants for rural residences, involving organic filters and solar reactorsRocha, André Luiz Marques 04 February 2013 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2017-05-31T12:27:30Z
No. of bitstreams: 1
texto completo.pdf: 2353197 bytes, checksum: c7857ff947a3da3dfb17abdaa73dd50c (MD5) / Made available in DSpace on 2017-05-31T12:27:30Z (GMT). No. of bitstreams: 1
texto completo.pdf: 2353197 bytes, checksum: c7857ff947a3da3dfb17abdaa73dd50c (MD5)
Previous issue date: 2013-02-04 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / A água de reuso é uma opção promissora do ponto de vista ambiental, já que contribui para diminuição da captação e consequentemente redução nas vazões de lançamento de efluentes. O lançamento de águas cinzas e águas negras sem tratamento no ambiente deprecia a qualidade de vida das populações em função do surgimento de várias doenças. O presente trabalho objetivou monitorar e avaliar a eficiência de uma estação de tratamento de águas cinzas (ETAC) e de uma estação de tratamento de águas negras (ETAN), visando o reaproveitamento não-potável das águas cinzas e das águas negras em comunidades rurais de baixa renda. A ETAC foi montada na comunidade rural Macena, no município de Viçosa-MG. Tal sistema era constituído de biofiltro, reatores solares e sumidouro, o qual foi monitorado no período de 23 de julho de 2009 a 01 de outubro de 2009. As análises físico-químicas e microbiológicas dos efluentes foram realizadas em distintos pontos do sistema para avaliação do desempenho. A ETAC foi montada no Delineamento Inteiramente Casualizado com três tratamentos (pontos de amostragem) e cinco repetições no tempo. De acordo com os resultados obtidos durante a avaliação da estação de tratamento de águas cinzas (ETAC), conclui-se que a (ETAC) proporcionou eficiências médias de remoções de 28%, 56%, 71,3%, 76,5%, 52,5%, 71%, 61%, 4,6% e 87% nas concentrações de Condutividade Elétrica (CE), Turbidez (TB), Demanda Química de Oxigênio (DQO), Demanda Bioquímica de Oxigênio (DBO), Sólidos Totais (ST), Sólidos Suspensos Totais (SST), Fósforo Total (P total ), Nitrogênio Total (N total ) e Óleos e Graxas (OG), respectivamente. Com relação às características microbiológicas, a ETAC obteve uma eficiência de remoção média de E. coli de 3 unidades logarítmicas. A ETAN foi montada na comunidade rural de Água Limpa do município de Cajuri-MG. Tal sistema foi constituído de caixa de gordura, tanque séptico, biofiltro, reatores solares e sumidouro, o qual foi monitorado no período de 7 de maio de 2009 a 25 de junho de 2009. As análises físico-químicas e microbiológicas dos efluentes foram realizadas em distintos pontos do sistema para avaliação do desempenho. O experimento para tratamento de águas negras foi montado no Delineamento Inteiramente Casualizado com quatro tratamentos (pontos de amostragem) e seis repetições no tempo. De acordo com os resultados obtidos durante a avaliação da estação de tratamento de águas negras (ETAN), conclui-se que a (ETAN) proporcionou eficiências médias de remoções de 46%, 88%, 78,2%, 85,8%, 61,5%, 91%, 75%, 14,4% e 67,8% nas concentrações de Condutividade Elétrica (CE), Turbidez (TB), Demanda Química de Oxigênio (DQO), Demanda Bioquímica de Oxigênio (DBO), Sólidos Totais (ST), Sólidos Suspensos Totais (SST), Fósforo Total (P total ), Nitrogênio Total (N total ) e Óleos e Graxas (OG), respectivamente. Com relação às características microbiológicas, a ETAN proporcionou uma eficiência de remoção média de E. coli de 2 unidades logarítmicas. / The water reuse is a promising alternative for the viewpoint of the environment, contributing to reduced absorption and reduces the flow of effluent discharge. The release of greywater and untreated sewage depreciates environmental quality of life of populations due to the onset of various diseases. This study aimed to monitor and evaluate the capacity of a treatment plant for greywater and a treatment of sewage, for non-potable reuse of greywater and blackwater in communities low-income rural. The treatment plant grey water was set up in the rural community Macena in Viçosa-MG. This system consists of biofilters, solar reactors and sinkhole, which was controlled in the period from July 23, 2009 to October 1, 2009. The physico-chemical and microbiological characteristics of the effluents were realized in different parts of the performance evaluation system. The treatment plant greywater was mounted in a completely randomized design with three treatments (sampling points) and five replications in time. According to the results obtained during the evaluation of the water treatment station ash, it is concluded that this treatment stationgave mean elimination efficiency of 28%, 56%, 71.3%, 76.5 %, 52.5%, 71%, 61%, 4.6% and 87% concentrations of electrical conductivity, turbidity, chemical oxygen demand, biochemical oxygen demand, total solids, total suspended solids, total phosphorus, total oil and grease, nitrogen, respectively. Regarding the microbiological characteristics, the treatment plant greywater obtained an average efficiency of removal of E. coli three logarithmic units.The station blackwater treatment was mounted in the rural community of Água Limpa, in Cajuri-MG.This system consisted of the grease trap, septic tank, biological filter, solar reactors and the sinkhole, which is monitored in the period from May 7, 2009 to June 25, 2009. The physico-chemical and microbiological characteristics of the effluents were carried out in different parts of the performance evaluation system. Experience in wastewater treatment was mounted in a completely randomized design with four treatments (sampling points) and six replications in time. According to the results obtained during the evaluation of treatment plant sludge, is follows that a gave mean elimination efficiency of 46%, 88%, 78.2%, 85.8%, 61.5%, 91%, 75%, 14.4% and 67.8% to levels of electrical conductivity, turbidity, chemical oxygen demand, biochemical oxygen demand, total solids, total suspended solids, total phosphorus, nitrogen total, oil and grease, respectively. Regarding the microbiological characteristics, the station blackwater treatment obtained an average efficiency of removal of E. coli two logarithmic units.
|
6 |
Redes neurais aplicadas à inferência dos sinais de controle de dosagem de coagulantes em uma estação de tratamento de água por filtração rápida / Artificial neural networks applied to the inference of dosage control signals of coagulants in a water treatment plant by direct filtrationGomes, Leonaldo da Silva 03 1900 (has links)
GOMES, L. da S. Redes neurais aplicadas à inferência dos sinais de controle de dosagem de coagulantes em uma estação de tratamento de água por filtração rápida. 2012. 98 f. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2012. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2012-09-13T18:15:13Z
No. of bitstreams: 1
2012_dis_lsgomes.pdf: 7198003 bytes, checksum: 6a4247c4aa5d59a00fb9744fef097ea9 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2012-09-25T14:35:04Z (GMT) No. of bitstreams: 1
2012_dis_lsgomes.pdf: 7198003 bytes, checksum: 6a4247c4aa5d59a00fb9744fef097ea9 (MD5) / Made available in DSpace on 2012-09-25T14:35:04Z (GMT). No. of bitstreams: 1
2012_dis_lsgomes.pdf: 7198003 bytes, checksum: 6a4247c4aa5d59a00fb9744fef097ea9 (MD5)
Previous issue date: 2012-03 / Considering the importance of the chemical coagulation control for the water treatment by direct filtration, this work proposes the application of artificial neural networks for inference of dosage control signals of principal and auxiliary coagulant, in the chemical coagulation process in a water treatment plant by direct filtration. To that end, was made a comparative analysis of the application of models based on neural networks, such as: Focused Time Lagged Feedforward Network (FTLFN); Distributed Time Lagged Feedforward Network (DTLFN); Elman Recurrent Network (ERN) and Non-linear Autoregressive with exogenous inputs (NARX). From the comparative analysis, the model based on NARX networks showed better results, demonstrating the potential of the model for use in real cases, which will contribute to the viability of projects of this nature in small size water treatment plants. / Considerando a importância do controle da coagulação química para o processo de tratamento de água por filtração rápida, esta dissertação propõe a aplicação de redes neurais artificiais para inferência dos sinais de controle de dosagem de coagulantes principal e auxiliar, no processo de coagulação química em uma estação de tratamento de água por filtração rápida. Para tanto, foi feito uma análise comparativa da aplicação de modelos baseados em redes neurais do tipo: alimentada adiante focada atrasada no tempo (FTLFN); alimentada adiante atrasada no tempo distribuída (DTLFN); recorrente de Elman (ERN) e auto-regressiva não-linear com entradas exógenas (NARX). Da análise comparativa, o modelo baseado em redes NARX apresentou melhores resultados, evidenciando o potencial do modelo para uso em casos reais, o que contribuirá para a viabilização de projetos desta natureza em estações de tratamento de água de pequeno porte.
|
7 |
Remoção do herbicida 2,4-D por meio do tratamento convencional da água e adsorção em carvão ativado granular em instalação pilotoBrega, Renata Santos 01 July 2014 (has links)
Submitted by Maykon Nascimento (maykon.albani@hotmail.com) on 2014-10-20T19:42:42Z
No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Dissertacao.texto completo.Renata.pdf: 2944882 bytes, checksum: a014f9f63e76c5f39ddf6fda8ee9a824 (MD5) / Approved for entry into archive by Elizabete Silva (elizabete.silva@ufes.br) on 2014-11-25T20:31:01Z (GMT) No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Dissertacao.texto completo.Renata.pdf: 2944882 bytes, checksum: a014f9f63e76c5f39ddf6fda8ee9a824 (MD5) / Made available in DSpace on 2014-11-25T20:31:02Z (GMT). No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Dissertacao.texto completo.Renata.pdf: 2944882 bytes, checksum: a014f9f63e76c5f39ddf6fda8ee9a824 (MD5)
Previous issue date: 2014 / O crescimento populacional empurra a produção agrícola em direção ao uso intensivo dos agrotóxicos que aumentam a produtividade. Porém, seu uso incorreto pode resultar em grave problema para as estações de tratamento da água e impactar negativamente na saúde pública. Segundo estudos em escala laboratorial, o tratamento convencional, um dos mais utilizados no Brasil, apresenta remoção insignificante do 2,4-D. A adsorção em carvão ativado tem se demonstrado como tecnologia eficiente na remoção de diversos contaminantes, dentre eles os agrotóxicos. Assim, foi avaliada a remoção dos herbicidas 2,4-D e 2,4,5-T e metabólito 2,4-DCP, utilizando o tratamento convencional e a adsorção em coluna de carvão ativado granular em instalação piloto. O carvão ativado granular empregado foi o derivado da casca de coco. A concentração dos herbicidas foi analisada por cromatografia líquida de alta eficiência com detector por arranjo de diodos e extração em fase sólida. A associação do tratamento convencional com a adsorção em carvão ativado granular apresentou elevada remoção do 2,4-D (99%) atingindo concentrações finais abaixo do limite da Portaria MS n° 2914/2011. O tratamento convencional, no entanto, também apresentou remoção do 2,4-D (35 a 59%), sendo o maior percentual obtido na decantação (30 a 52%), indicando que houve interação entre a matéria orgânica natural e o 2,4-D, contribuindo para sua remoção nessa etapa. O 2,4-DCP e 2,4,5-T apresentaram concentrações abaixo do limite de detecção. / The population growth pushes agricultural production towards intensive use of pesticides that increase productivity. However, incorrect use can result in serious problem at water treatment plants and negatively impact in public health. According to laboratory-scale studies, conventional treatment, one of the most used in Brazil, presents negligible removal of 2,4-D. The activated carbon adsorption have been documented to be effective for the removal of various contaminants, including pesticides. Thus, it was evaluated the removal of the herbicides 2,4-D and 2,4,5 -T and metabolite 2,4- DCP using the conventional treatment and granular activated carbon adsorption, in a pilot-plant. The granular activated carbon used was manufactured from coconut shell. The herbicides concentration was analyzed by High Performance Liquid Chromatography with diode array detection and solid phase extraction. The combination of conventional treatment and granular activated carbon adsorption showed high removal of 2,4-D (99%) reaching final concentrations below the limit of Portaria MS n° 2914/2011. Conventional treatment, however, also showed considerable removal of 2,4- D (35-59%), with a high percentage removal obtained in sedimentation (30-52%), suggesting that there were interaction between natural organic matter and 2,4-D, increasing the removal in this step. 2,4-DCP and 2,4,5-T showed concentrations below the detection limit.
|
8 |
Caracterização e avaliação do pontencial de destinação do lodo de estações de tratamento de água do Estado do ParanáGervasoni, Ronald 17 April 2017 (has links)
Orientadora : Profª Drª. Patricia Charvet / Coorientador: Prof. Dr. Regina Maria Matos Jorge / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Mestrado Profissional em Meio Ambiente Urbano e Industrial, em parceria com o Serviço Nacional de Aprendizagem Industrial e a Universität Stuttgart. Defesa: Curitiba, 30/09/2014 / Inclui referências : f. 109-120 / Resumo: O lodo gerado na potabilização da água em Estações de Tratamento de Água (ETAs) é enquadrado como resíduo sólido classe II A (não perigoso e não inerte), de acordo com a NBR 10.004/2004. A disposição inadequada deste resíduo pode provocar a degradação do meio ambiente, a contaminação de mananciais e do solo. Assim sendo, observa-se a importância de estudos para o tratamento e disposição final correta do lodo. Cada ETA gera lodo com características diferentes, dependendo do tratamento aplicado. Portanto, é preciso o conhecimento destas características para que se possam definir os destinos. Conforme estas considerações iniciais, o presente estudo tem como objetivo caracterizar os lodos provenientes das ETAs pertencentes à Companhia de Saneamento do Paraná (SANEPAR), por meio de análises químicas, físicas e microbiológicas e por meio de entrevistas dirigidas. No Paraná existem 176 ETAs operantes. Para este estudo foram selecionadas 44 ETAs, de acordo com os seguintes critérios: região geológica; bacia hidrográfica; tipo de solo; e unidades regionais da SANEPAR. A coleta de lodo nas ETAs foi realizada em triplicata nos períodos de estiagem e chuvoso. Os parâmetros analisados foram: metais (As, Ba, Cd, Cu, Ni, Se, Pb, Zn, Hg, Cr, Al, Mo e Fe), série de sólidos, DQO, DBO, pH e índices microbiológicos (coliformes termotolerantes e ovos de helmintos). Os resultados das coletas apontaram um pH médio de 6,9, sendo que, em 52% das ETAs, o pH permaneceu entre 6,0 e 7,0. Quanto à DQO, o valor mais alto foi de 55.347 mg/L de O2. Os valores de DBO variaram entre 6 e 1.996 mg/L de O2 e a relação DQO/DBO resultou em valores superiores a 5 em todas as amostras, o que indica que sua composição é dada majoritariamente por compostos inorgânicos. Quanto aos sólidos, 64% das ETAs apresentaram lodo com teor de sólidos totais abaixo de 5%, confirmando a elevada umidade desse resíduo. Em geral, foram obtidas baixas concentrações de metais nas amostras de lodo, sendo que destes os maiores índices foram de Al (22.720 mg/L) e Fe (57.870 mg/L). Quantos aos parâmetros biológicos foram constatados ovos viáveis de helmintos em 47% das ETAs e, em alguns casos, foram encontrados níveis elevados de coliformes termotolerantes mesmo se tratando de um resíduo proveniente do tratamento da água bruta. Em geral, como foram analisados dois períodos distintos, no período de estiagem predominou uma concentração maior dos analitos do que no período chuvoso, fato já observado por outros autores. O conjunto dos resultados obtidos evidencia a necessidade de avaliar cada ETA separadamente devido à heterogeneidade dos resultados e através desta análise propor alternativas para o tratamento e disposição do lodo de ETA. A partir destes comentários se deve ter em mente que, para a gestão do lodo de ETA, o gestor deve ter uma visão geral sobre a produção, característica e alternativas de descarte, reciclagem e reaproveitamento deste resíduo no meio ambiente. Tal visão contribui para modificar a atual conjuntura e abordagem da problemática dos resíduos sólidos produzidos nas estações de tratamento de água. Deste modo, este lodo deixa de ser visto como um simples resíduo a ser descartado para uma postura coerente com princípios de desenvolvimento sustentável e potencial de reaproveitamento. PALAVRAS-CHAVE: SANEPAR. Características. Disposição. Aproveitamento. Lodo. / Abstract: The sludge generated in water potability in Water Treatment Plants (WTP) is framed as class II (not dangerous and not inert) solid waste, according to Brazilian Association of Technical Standards - NBR 10004/2004. The improper disposal of these wastes can cause environmental degradation, contamination of water sources and soil. Thus, are very important of studies for the treatment and proper disposal of sludge. Each WTP generates sludge with different characteristics, depending on the applied treatment. Therefore the knowledge of these features is needed to define an appropriate disposal. Considering these initial attributes, this study aims to characterize the sludge from the water treatment plants belonging to the Sanitation Company of Paraná state (SANEPAR), by chemical, physical and microbiological and through directed interviews analysis. In Parana there are 176 operative and WTP. For this study 44 WTP were selected, according to the following criteria: geological region; watershed; soil type; and regional units SANEPAR. The collection of the WTP sludge was performed in triplicate during the dry an rainy seasons. The parameters analyzed were: metals (As, Ba, Cd, Cu, Ni, Se, Pb, Zn, Hg, Cr, Al, Mo and Fe), solids, COD, BOD, pH and microbiological indices (fecal coliform and helminthes eggs). The results showed an average pH of 6.9, and in 52% of the WTP, the pH remained between 6.0 and 7.0. As to the COD, the highest value was 55,347 mg/L O2. The BOD values varied between 6 and 1,996 mg/L O2 and the COD / BOD ratio resulted in values greater than 5 in all samples, indicating that its composition is mainly given by inorganic compounds. As for solids, 64% of WTP showed sludge with solids content below 5%, confirming the high humidity of this residue. In general, low concentrations of metals in sludge samples were obtained, and these were the highest rates of Al (22,720 mg/L) and Fe (57,870 mg/L). Viable eggs in 21 water treatment plants were found and, in some cases, high levels of fecal coliform were found even when dealing with the waste from the treatment of raw water. In general, as two distinct periods were analyzed, in the drought prevailed higher concentrations of the analytes than in the rainy season, a fact already observed by other authors. The set of results highlights the need to evaluate each separately WTP due to the heterogeneity of the results, and through this analysis to propose alternatives for the treatment and disposal of Water Treatment Sludge (WTS). From these comments should keep in mind that for the management of WTS, managers should have an overview on the production, characteristics and alternative disposal, recycling and reuse of this waste in the environment. Such a view helps to change the current situation and the problem of solid waste produced in water treatment stations approach. Thus this sludge is no longer seen as a simple waste to be discarded for a coherent approach to the principles of sustainable development and potential for reuse. KEYWORDS: SANEPAR. Characteristics. Disposal. Utilization. Sludge.
|
9 |
Água tratada : formação de trialometanos pelo uso do cloro e os riscos potenciais à saúde pública em cidades da mesorregião do leste rondonienseLeão, Vonivaldo Gonçalves January 2008 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, 2008. / Submitted by Fernanda Weschenfelder (nandaweschenfelder@gmail.com) on 2009-10-01T16:37:34Z
No. of bitstreams: 1
2008_VonivaldoGoncalvesLeao.pdf: 1155017 bytes, checksum: 1b88ff500969bbffafe217ae8a09a07a (MD5) / Approved for entry into archive by Marília Freitas(marilia@bce.unb.br) on 2010-02-12T22:44:01Z (GMT) No. of bitstreams: 1
2008_VonivaldoGoncalvesLeao.pdf: 1155017 bytes, checksum: 1b88ff500969bbffafe217ae8a09a07a (MD5) / Made available in DSpace on 2010-02-12T22:44:01Z (GMT). No. of bitstreams: 1
2008_VonivaldoGoncalvesLeao.pdf: 1155017 bytes, checksum: 1b88ff500969bbffafe217ae8a09a07a (MD5)
Previous issue date: 2008 / Nos sistemas de abastecimento de água potável é comum o uso do cloro e de seus
derivados. O poder de oxidação do cloro livre sobre bactérias reduz e protege a
água contra as proliferações de microorganismos. A mesorregião leste do estado de Rondônia, composta pelos municípios Cacoal, Ji-Paraná, Espigão d’Oeste, Pimenta Bueno, Rolim de Moura, Alta Floresta d’Oeste, Ministro Andreazza e Presidente Médici que fizeram parte do estudo desta dissertação, é caracterizada pela presença de rios que servem como captação de água a ser tratada e fornecida à população. Devido a vários estudos realizados com relação à presença de contaminantes químicos formados após a cloração da água, principalmente a formação de trialometanos, estudos estes que procuram correlacionar a possibilidade destes
compostos serem carcinogênicos e mutagênicos, neste trabalho foram analisados os níveis de trialometanos formados nas estações de tratamento de água. As amostras
foram coletadas em épocas sazonais e os resultados demonstraram a existência de
pontos críticos quanto à formação de trialometanos, dentre eles alguns possíveis
motivos são: em Ji-Paraná a água bruta contendo contaminação de trialometanos,
principalmente diclorometano, e também a disposição dos equipamentos, provocando um maior contato do cloro livre com substâncias orgânicas. Em Alta Floresta d’Oeste a precariedade nos decantadores e filtros que não condiz com a vazão de tratamento. De acordo com este estudo em épocas chuvosas há
diminuição dos níveis de trialometanos, diferentes dos apresentados em estudos em
outras localidades. Há a possibilidade das características do solo na região de estudo influenciar e fazer com que haja diluição do leito conforme dados físicoquímicos apresentados. Também não é descartado o alto índice de partículas sólidas, produtos de combustão de matas na região durante o período de estiagem. A absorção de substâncias particuladas pode influenciar nos níveis de formação de subprodutos de cloração, além do alto índice de CO2 presente na atmosfera. Nas demais estações de tratamento de água, há formação de trialometanos, mas nos níveis abaixo dos especificados pela Portaria 518/2004 do Ministério da Saúde. Não há relato de estudos realizados quanto aos níveis de trialometanos nas águas de abastecimento público no Estado de Rondônia. É importante um acompanhamento periódico quanto à formação dos produtos e um estudo mais aprofundado de adequação de tempo de exposição com cloro livre para minimizar ainda mais os níveis formados de trialometanos. Importante também um monitoramento nas águas dos rios que já possuem formação ou apresentam uma certa quantidade de trialometanos, que podem ser resíduos industriais. A saúde pública é uma prioridade e a água contendo trialometanos pode estar correlacionada com doenças
carcinogênicas e mutagênicas. ________________________________________________________________________________________ ABSTRACT / In the water supplies of drinking water is the common use of chlorine and its derivatives. The powers of oxidation of free chlorine on reducing bacteria and protect
the water against the proliferations of microorganisms. The mesoregion eastern state
of Rondonia, made by municipalities Cacoal, Ji-Parana, Espigão d'Oeste, Pimenta Bueno, Rolim de Moura, Alta Floresta d'Oeste, Ministro Andreazza and Presidente Medici that were part of the study of this dissertation, is characterized by the
presence of rivers that serve as abstraction of water to be treated and supplied to the
population. Due to various studies with respect to the presence of chemical
contaminants formed after the chlorination of water, mainly the formation of
trihalomethanes, these studies seeking to correlate the possibility of these compounds are carcinogenic and mutagenic, in this study were analyzed the levels of
trihalomethanes formed at stations water treatment plants. The samples were collected in times seasonal and the results demonstrated the existence of hot spots
on the formation of trihalomethanes, including some possible reasons are: Ji-Parana in the contamination of raw water containing trihalomethanes, especially
dichloromethane, and also the provision of equipment, causing a greater contact of
free chlorine with organic substances. In Alta Floresta d'Oeste in the precarious
decanters and filters that is not compliant with the flow of treatment. According to this
study in rainy seasons are decreased levels of trihalomethanes, different from those
presented in studies in other locations. There is the possibility of soil characteristics in the region of study and influence to make dilution of the bed as physical-chemical data submitted. It is not discarded the high rate of solid particles, products of burning of forests in the region during the drought. The absorption of particulate substances can influence the levels of training for byproducts of chlorination, in addition to this high rate of CO2 in the atmosphere. In other water treatment plants, there is formation of trihalomethanes, but at levels below those specified by the Ordinance 518/2004 of the Ministério da Saúse. There is no report of studies about the levels of trihalomethanes in public water supply in the state of Rondônia. It is important periodic monitoring on the training of products and further study of adequacy of time of exposure with free chlorine to minimize further the levels of trihalomethanes
formed. Important also a tracking in the waters of rivers that already have training or have a certain amount of trihalomethanes, which can be industrial waste. Public health is a priority and water containing trihalomethanes can be correlated with
disease carcinogenic and mutagenic.
|
10 |
Comparação de leituras de turbidez de amostras de água bruta e tratada em diferentes equipamentos: contribuições à Portaria MS no 2914/2011 / Comparison of turbidity measurements of raw and treated water samples in different instruments: contributions to the Brazilian drinking-water quality regulationFerreira, Larissa Candian 19 February 2018 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2018-09-17T13:57:06Z
No. of bitstreams: 1
texto completo.pdf: 1500002 bytes, checksum: 2b28d416576bc7c3dfcca6c710271a2b (MD5) / Made available in DSpace on 2018-09-17T13:57:06Z (GMT). No. of bitstreams: 1
texto completo.pdf: 1500002 bytes, checksum: 2b28d416576bc7c3dfcca6c710271a2b (MD5)
Previous issue date: 2018-02-19 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho, avaliou-se a confiabilidade analítica e diferenças entre leituras de turbidez de amostras de água bruta, decantada e filtrada da Estação de Tratamento de Água da Universidade Federal de Viçosa tendo em conta dois dos principais fatores de interesse na medição de turbidez: operadores e equipamentos. Foram utilizados quatro turbidímetros portáteis (três de mesma marca e modelo), seis equipamentos on line (cinco de mesma marca e modelo) e um de bancada. A pesquisa foi dividida em dois estudos: (i) Estudo 1, entre maio de 2015 e março de 2016, quando foram avaliadas diferenças entre leituras de turbidez realizadas por dois operadores com os equipamentos portáteis e de bancada; (ii) Estudo 2, entre de julho de 2016 e setembro de 2017, no qual foram avaliadas diferenças entre leituras fornecidas pelos equipamentos de bancada e on line. Nos dois estudos, o turbidímetro de bancada foi assumido como o equipamento padrão (aquele que forneceria os valores “verdadeiros” de turbidez). Tendo isso em conta e tomando como referência os limites especificados na norma brasileira de qualidade da água para consumo humano para turbidez de efluentes de filtros rápidos - 0,50 uT (máximo permitido) e 0,30 uT (recomendação), foram avaliadas a confiabilidade (acurácia) das medidas de turbidez, além da sensibilidade e especificidade dos equipamentos (respectivamente, a capacidade de detectar valores inferiores e acima dos valores de referência). Em geral, o teste de confiabilidade demonstrou que a acurácia das medidas fornecidas pelos demais equipamentos em relação ao turbidímetro de bancada foi baixa, particularmente para medidas abaixo de 0,3 uT no caso dos turbidímetros portáteis e entre 0,3-0,5 uT no caso dos equipamentos on line. Também em linhas gerais, os turbidímetros portáteis e on line apresentaram elevada sensibilidade, mas especificidade mais baixa, comparativamente ao equipamento de bancada. Testes estatísticos de diferença de médias mostraram que no Estudo 1 houve diferença significativa entre as leituras realizadas pelos dois operadores nas faixas de valores mais baixas de turbidez (até 0,50 uT); entre equipamentos, as diferenças foram maiores também para valores mais baixos de turbidez e diminuíram em mais valores altos (não houve diferença significativa na faixa de 5,1 a 10 uT). No Estudo 2, foram observadas diferenças significativas entre os todos os equipamentos e para todas os tipos de água, com o equipamento de bancada apresentando leituras maiores do que um dos equipamentos on line, porém mais baixas que as do outro. Não obstante, todas as diferenças foram muito pequenas em magnitude, particularmente nas leituras de turbidez de água filtrada. Conclui-se que o atendimento dos limites de turbidez de água filtrada especificados na norma brasileira de qualidade da água para consumo humano pode ser verificado independentemente do equipamento utilizado. / In this work, the analytical reliability and differences between turbidity readings of raw, settled and filtered water samples from the University of Viçosa water treatment plant were evaluated taking into account two of the main factors of interest in turbidity measurements: operators and instruments. Four portable turbidimeters (three of the same brand and model), six online instruments (five of the same brand and model) and one benchtop turbidimeter were used. The research was comprise of two separate studies: (i) Study 1, from May 2015 to March 2016, when differences between turbidity readings carried out by two operators using portable and benchtop instruments were compared; (ii) Study 2, from July 2016 to September 2017, in which differences between readings provided by the bench and the online instruments were evaluated. In both studies, the benchtop turbidimeter was assumed as the standard instrument (the one that would provide the "true" turbidity values). Taking this into account and having the Brazilian drinking-water quality standards for rapid sand filtration as references – 0.50 uT (maximum) and 0.30 uT (recommendation), the reliability (accuracy) of the turbidity measurements and the instrument’s sensitivity and specificity (respectively, the ability to detect values lower than and above the reference values) were evaluated. In general, the reliability test showed that the accuracy of the measurements provided by all other instruments relatively to the benchtop turbidimeter was low, particularly for measurements below 0.3 uT in the case of the portable turbidimeters, and for readings between 0.3-0.5 uT in the case of the online instrument. Generally, portable and online turbidimeters presented high sensitivity, but lower specificity, compared to benchtop instrument. The statistical tests showed that in Study 1 there were significant differences between readings carried out by the two operators in the lowest range values of turbidity (up to 0.50 uT); between instruments, the differences were also higher for lower turbidity values and decreased in higher values (there was no significant difference in the range of 5.1 to 10 uT). In Study 2, there were significant differences between all the equipment and for all waters types, with benchtop readings higher than those of one of the online turbidimeter, but lower than the other. Nevertheless, all differences were very small in magnitude, particularly for filtered water readings. It is concluded that compliance with the filtered water turbidity threshold values specified in the Brazilian drinking-water quality standard can be evaluated regardless of the type of turbidimeter used.
|
Page generated in 0.1469 seconds