• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • 1
  • Tagged with
  • 14
  • 14
  • 8
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Identificação e verificação da resistência aos sanitizantes dos microrganismos presentes na água destinada ao abastecimento público e em um sistema de purificação / Identification and verification of resistance to the sanitizers of microorganisms present in the water for public supply and a purification system

Martins, Alzira Maria da Silva 14 October 2002 (has links)
Água purificada para uso em ambientes de saúde e preparação industrial de produtos médico-odonto-hospitalar deve ter uma carga reduzida de contaminação microbiológica e pirogênio. As amostras analisadas foram coletadas em 13 (treze) diferentes estágios de um sistema de purificação de água, sendo isoladas 78 colônias. Para a identificação dos microrganismos foram utilizados: (i) identification system for non-enteric gram-negative rods (api 20 NE, bio Mérieux) e (ii) identification system for enteric and nonfermenter (BBL crystal, Becton Dickinson). De acordo com os resultados pode-se observar uma maior prevalência para Pseudomonas aeruginosa 32,05% (25 colônias dentre as 78 isoladas); Pseudomonas picketti 23,08% (18); Pseudomonas vesiculares 12,82% (10); Pseudomonas diminuta 11,54% (09); Flavobacterium aureum 6,42% (05); Pseudomonas fluorescences 5,13% (04); Acinetobacter Iwoffi 2,56% (02); Pseudomonas putida 2,56% (02); Pseudomonas alcaligenes 1,28% (01); Pseudomonas paucimobilis 1,28% (01), Flavobacterium multivorum 1,28% (01). A eficácia dos agentes sanitizantes utilizados para higienização dos diferentes pontos foi determinada pela concentração inibitória mínima (CIM) e tempo de redução decimal (valor D). Como o hipoclorito de sódio é largamente utilizado na higienização do tanque de água de alimentação, tanque de estocagem da água purificada e nas linhas de distribuição aos pontos de uso, este foi testado frente a todos os microrganismos sendo observado menor resistência para Escherichia coli ATCC 25922 (0.06%=600mg/L), quando comparada a P. aeruginosa isolada e identificada (O,25%=2500mg/L). O tempo de redução decimal (Valor D) da Escherichia coli ATCC 25922 foi de 4 minutos e o valor D da P. aeruginosa isolada e identificada e isolada in house foi de 9 minutos. / The samples of water, which were taken directly from the public distribution water tank and at twelve different stages of a typical purification system, were analyzed for the identification of isolated bacteria. The efficacy of the chemical sanitizers used in the stages of the system, over the isolated and identified bacteria in the sampling water, was valuated by the minimum inhibitory concentration (MIC and decimal reduction time (D-values). According to the miniature kits used in the identification, there was a prevalence of isolation by P. aeruginosa 32,05 % , P. picketti (Ralstonia picketti) 23,08%, P. vesiculares 12,82%, P. diminuta 11.54%, F.aureum 6,42%, P.fluorescens 5,13%, A.lowffi 2,56%, P.putida 2,56%, P. alcaligenes 1,28%, P.paucimobilis 1,28%, and F. multivorum 1,28%. The efficacy of the agents varied with the concentration and time of contact to reduce a decimal logarithmic (loglO) population (n cycles): (i) 0.5% citric acid (0= 4 min) for 30 min reduced n=7 cycles; (ii) 0.5% chloridric acid (0= 6 min) for 30 min reduced n= 4 cycles; (iii) 70% alcohol (0= 9 min) for 1.0 min (n=0.2 cycles); (iv) 0.5% sodium bisulphite (0= 6 min) for 90 min (n=14 cycles); (v) 0.4% sodium hydroxide (0= 8 min) for 30 min (n=3.0 cycles); (vi) 0.5% sodium hypochlorite (0=9 min) for 180 min (n = 19 cycles); (vii) mixture of hydrogen peroxide (2,2%) plus peracetic acid (0.45%), 0= 6 min, contact time of 180 min, reduced n = 32 cycles of the population. The sterility assurance level (SAL) of 10-6 was attained for the 0.5% sodium hypochlorite solution applied in the water purified storage tank and distribution loop; and for the mixture of H2O2 plus peracetic acid, used in the reverse osmose and in the deionizator systems.
12

Blue rayon como alternativa para extração de compostos orgânicos genotóxicos presentes em amostras de águas / Blue Rayon as an alternative for extraction of genotoxic organic compounds present in water samples

Kummrow, Fabio 13 December 2001 (has links)
A combinação do teste de Ames e métodos seletivos de extração para os principais grupos de compostos responsáveis pela atividade genotóxica em amostras ambientais tem sido muito utilizada. O objetivo foi validar o uso do Blue rayon como alternativa para extração de compostos presentes em águas brutas e tratadas. Foram realizados experimentos comparativos entre o Blue rayon e XAD-4 com amostras fortificadas e amostras reais. Dois mananciais, um contaminado com compostos policíclicos e outro não, foram estudados. As amostras foram extraídas com resina XAD4, e com Blue rayon, este último seletivo para compostos policíclicos. Os extratos foram testados com as linhagens de Salmonella typhimurium TA98 e TA100 na presença e ausência de mistura S9. O Blue rayon foi menos eficiente na detecção da mutagenicidade total das amostras quando comparado com a XAD-4. Porém foi capaz de distinguir a mutagenicidade já presente na água bruta daquela gerada durante o tratamento. / The combination of the Ames test and selective extraction methodologies has been successfully used to indicate the possible classes of organic contaminants in environmental samples. The aim of this study was to validate the use of Blue rayon as an alternative extraction method to detect compounds in raw and treated waters. Two different water bodies were evaluated and in one of the sites, raw waters were known to be contaminated with polycyclic compounds. Experiments comparing the Blue rayon technique with XAD-4 resin were done in environmental and spiked samples. The extracts were tested for mutagenicity with Salmonella typhimurium strains TA98 and TA100, with and without metabolic activation. Blue rayon was less efficient in detecting the overall mutagenicity of the samples analyzed in comparison with XAD-4. It was able though to distinguish the mutagenicity due to the contaminants in raw from the ones generated by water treatment.
13

Blue rayon como alternativa para extração de compostos orgânicos genotóxicos presentes em amostras de águas / Blue Rayon as an alternative for extraction of genotoxic organic compounds present in water samples

Fabio Kummrow 13 December 2001 (has links)
A combinação do teste de Ames e métodos seletivos de extração para os principais grupos de compostos responsáveis pela atividade genotóxica em amostras ambientais tem sido muito utilizada. O objetivo foi validar o uso do Blue rayon como alternativa para extração de compostos presentes em águas brutas e tratadas. Foram realizados experimentos comparativos entre o Blue rayon e XAD-4 com amostras fortificadas e amostras reais. Dois mananciais, um contaminado com compostos policíclicos e outro não, foram estudados. As amostras foram extraídas com resina XAD4, e com Blue rayon, este último seletivo para compostos policíclicos. Os extratos foram testados com as linhagens de Salmonella typhimurium TA98 e TA100 na presença e ausência de mistura S9. O Blue rayon foi menos eficiente na detecção da mutagenicidade total das amostras quando comparado com a XAD-4. Porém foi capaz de distinguir a mutagenicidade já presente na água bruta daquela gerada durante o tratamento. / The combination of the Ames test and selective extraction methodologies has been successfully used to indicate the possible classes of organic contaminants in environmental samples. The aim of this study was to validate the use of Blue rayon as an alternative extraction method to detect compounds in raw and treated waters. Two different water bodies were evaluated and in one of the sites, raw waters were known to be contaminated with polycyclic compounds. Experiments comparing the Blue rayon technique with XAD-4 resin were done in environmental and spiked samples. The extracts were tested for mutagenicity with Salmonella typhimurium strains TA98 and TA100, with and without metabolic activation. Blue rayon was less efficient in detecting the overall mutagenicity of the samples analyzed in comparison with XAD-4. It was able though to distinguish the mutagenicity due to the contaminants in raw from the ones generated by water treatment.
14

Efeito da amônia sobre a fertilização artificial de ovócitos e no desenvolvimento inicial do jundiá cinza (Rhamdia quelen; Siluriformes, Heptapteridae) / Effect of ammonia on the artificial fertilization of oocytes and early development of jundia (Rhamdia quelen, Siluriformes, Heptapteridae)

Vidal, Eléxio 22 February 2012 (has links)
Made available in DSpace on 2017-07-10T18:13:31Z (GMT). No. of bitstreams: 1 Elexio Vidal.pdf: 493644 bytes, checksum: 4341c5aa354b0f3d92a326ffb2cccd46 (MD5) Previous issue date: 2012-02-22 / The aim study it had as objective to evaluate the effect of different ammonia levels, on the parameters of sperm motility, the artificial fertilization and the early development of jundia (Rhamdia quelen; Siluriformes, Heptapteridae). The semen was activated using the dilution of 1:70 (semen:water) and evaluated by the CASA method. It was considered as treatment water contending 0,06; 0,28; 0,50; 0,77 and 0,84 mg of total ammonia.water-1 L, so for sperm activation as for fertilization and incubation of the oocytes. The incubation was composed for a recirculation system of 250L for each treatment, with four incubators, being that each incubator approximately had useful volume of 2,5L with 3,800 eggs. Had been evaluated the parameters of sperm motility, fertilization rate, thermal unit accumulated for beginning and ending of the hatching, hatching rate, embryonic and percentile development of normal larvae. The results had been submitted the analysis of variance and the analysis of regression to a 5% of probability level. The ammonia levels gifts in the water did not interfere on the evaluated parameters (p> 0,05), except about to the early embryonic development, where the embryos displayed to the biggest levels of contamination for ammonia had presented greaters (p>0,05) closing of the blastopore rates. In general way, the presence of until 0,84mg of total ammonia. Water-1 L speeds up the embryonic early development but they do not interfere with the fertilization and hatching rates. / O presente estudo teve como objetivo avaliar os efeitos de diferentes níveis de amônia, sobre os parâmetros de motilidade espermática, a fertilização artificial e o desenvolvimento inicial do jundiá cinza (Rhamdia quelen; Siluriformes, Heptapteridae). O sêmen foi ativado utilizando a diluição de 1:70 (sêmen:água) e avaliado pelo método CASA. Foi considerado como tratamento água contendo 0,06; 0,28; 0,50; 0,77 e 0,84 mg de amônia total.L de água-1, tanto para ativação espermática quanto para fertilização e incubação dos ovócitos. A incubação era composta por um sistema de recirculação de 250L para cada tratamento, com quatro incubadoras, sendo que cada incubadora tinha volume útil de 2,5L com aproximadamente 3.800 ovos. Foram avaliados os parâmetros de motilidade espermática, de taxa de fertilização, unidade térmica acumulada para início e término da eclosão, taxa de eclosão, desenvolvimento embrionário e percentual de larvas normais. Os resultados foram submetidos a análise de variância e a análise de regressão a um nível de 5% de probabilidade. Os níveis de amônia presentes na água não interferiram sobre os parâmetros avaliados (p>0,05), exceto quanto ao desenvolvimento embrionário inicial, onde os embriões expostos aos maiores níveis de contaminação por amônia apresentaram maiores (p<0,05) taxas de fechamento do blastóporo. De modo geral, a presença de até 0,84mg de amônia total.L de água-1 acelera o desenvolvimento inicial embrionário mas não interferem nas taxas de fertilização e eclosão.

Page generated in 0.0755 seconds