• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 619
  • 7
  • 6
  • 6
  • 6
  • 6
  • 4
  • 2
  • Tagged with
  • 643
  • 643
  • 342
  • 221
  • 167
  • 144
  • 127
  • 107
  • 92
  • 84
  • 80
  • 77
  • 76
  • 67
  • 66
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Estudo da otimização do processo H2O2/UV para degradação do corante remazol vermelho RB 133% / Study of the process optimization h2O2/UV for degradation of the dye Remazol Red RB 133%

Ribeiro, Jefferson Pereira 25 May 2011 (has links)
RIBEIRO, J. P. Estudo da otimização do processo H2O2/UV para degradação do corante remazol vermelho RB 133%. 2011. 89 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2011. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-05-13T16:43:02Z No. of bitstreams: 1 2011_dis_jpribeiro.pdf: 1571759 bytes, checksum: 21f017748be8743ca27783d0c7f877b9 (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-05-25T17:02:04Z (GMT) No. of bitstreams: 1 2011_dis_jpribeiro.pdf: 1571759 bytes, checksum: 21f017748be8743ca27783d0c7f877b9 (MD5) / Made available in DSpace on 2016-05-25T17:02:04Z (GMT). No. of bitstreams: 1 2011_dis_jpribeiro.pdf: 1571759 bytes, checksum: 21f017748be8743ca27783d0c7f877b9 (MD5) Previous issue date: 2011-05-25 / Industrial processes that consume excess of water, typically generates a high volume of effluent, where the textile industry is a typical example. The oxidation chemistry is one of the alternative processes for the textile dyes treatment. In this context, the Advanced Oxidation Processes (AOPs) are based on the generation of hydroxyl radicals (.OH) on which are highly oxidizing compounds can decompose quickly and non-selective contaminant solutes, for a partial or complete mineralization. This study investigated the use of advanced oxidation process for degradation of the dye Remazol Red RB 133%. The studies were conducted in two stages. For first step, in the reactor with 710 mL of working volume , were studies the parameters: kinetic effect, hydrogen peroxide dosage, temperature, pH, addition of hydrogen peroxide in the line. The kinetics study decolorization and the inhibitory effect of anions were also studied. The study of kinetic showed that in 250 minutes there was a complete decolorization of the solution using a H2O2 dose of 1% (v/v) through the use of UV radiation, and a 78.41% removal in Chemical Oxygen Demand (COD) was observed. The pH effect not influenced in the decolorization process; however has been influenced in removal of COD. The study of temperature effect showed that for an increase in temperature the decolorization rate increases, but a small improvement in the efficiency of COD removal. The addition of H2O2 during the process increased the efficiency of COD removal. The results of the efficiencies of the end of the process indicated that there was no difference between treatments in the presence of anions in the studied concentration (10 mM) when compared to degradation without the presence of these anions, since the end of all treatments, the solution was colorless. In the second stage, was carried in the reactor with 520 mL of working volume flow studies were performed and power of UV radiation. The studies of flow rate showed that for flow rate of 1.0; 2.0 and 3.0 L/min there was no significant difference in the process decolorization process. The of organic matter concentrations at 480 minutes of experiment for the three flow rates were 36.63%, 51.08% and 48.35% respectively. The increased power of UV radiation caused an increase in the XII efficiency of discolouration and degradation of organic matter. The study showed a real effluent with low efficiency to reduce color and chemical oxygen demand. / As atividades industriais que consomem excesso de água no seu processo industrial, geralmente geram um elevado volume de efluentes, onde a indústria têxtil é um exemplo típico. A oxidação química é um dos processos alternativos para o tratamento de efluentes contendo corantes têxteis, entre eles destacam-se os POAs que são baseados na geração de radicais hidroxilas (.OH) no qual são altamente oxidantes, podendo decompor compostos de maneira rápida e não-seletiva, conduzindo a mineralização parcial ou completa do contaminante. O presente trabalho estudou o uso de processo oxidativo avançado para a degradação do corante Remazol Vermelho RB 133%. Os estudos foram realizados em duas etapas. Na primeira etapa, no reator com 710 mL de volume útil, foram realizados estudos de otimização dos parâmetros: cinética de descoloração, dosagem do peróxido de hidrogênio, pH, temperatura, adição de peróxido de hidrogênio em linha. A cinética de descoloração, e o efeito inibitório de ânions também foram estudados. O estudo de cinética mostrou que em 250 minutos houve uma descoloração completa da solução usando uma dosagem de peróxido de hidrogênio de 1% H2O2 mediante o uso da radiação UV. Nestas condições houve uma remoção de 78,41% na DQO. O pH não influenciou no processo de descoloração da solução, em contraste, para valores de pH iniciais 8 e 10 houve uma maior remoção na DQO. O estudo do efeito da temperatura do sistema mostrou que com o aumento temperatura a velocidade de descoloração é pouco influenciada, ao passo que o aumento da temperatura (80°C) diminuiu a eficiência do processo de remoção da DQO. A adição de H2O2 em linha do processo aumentou a eficiência na remoção de DQO. Os resultados das eficiências de remoção ao final do processo indicaram que não houve diferença entre os tratamentos na presença dos ânions na concentração estudada (10 mM) quando comparada a degradação sem a presença desses ânions, pois ao final de todos os tratamentos a solução ficou incolor. Na segunda etapa, no reator com 520 mL de volume útil, foram realizados estudos de vazão e potência de radiação UV. O estudo mostrou que para as vazões estudadas 1,0; 2,0 e 3,0 L/min não houve uma X diferença significativa no processo de descoloração. As concentrações da matéria orgânica ao final de 480 minutos de experimento para as três vazões foram 36,63%; 51,08% e 48,35%, respectivamente. O aumento da potência de radiação UV proporcionou um aumento na eficiência do processo de descoloração e degradação da matéria orgânica. O estudo com efluente real mostrou uma baixa eficiência na redução de cor e de demanda química de oxigênio.
182

Integração dos processos de eletroflotação e filtração granular descendente para o tratamento de água de produção de petróleo

Nonato, Thyara Campos Martins January 2017 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2017. / Made available in DSpace on 2017-07-04T04:03:47Z (GMT). No. of bitstreams: 1 346682.pdf: 3020190 bytes, checksum: cbda2a4f3af233416b319b831e62b800 (MD5) Previous issue date: 2017 / Um dos principais problemas enfrentado pela indústria petrolífera está relacionado à quantidade de água de produção gerada durante o processo de extração de petróleo e, consequentemente, a destinação final deste efluente, o qual deve passar por processos de tratamento visando atender as especificações para descarte nos oceanos ou injeção em poços de petróleo. Dessa forma, a presente pesquisa teve como objetivo avaliar a eficiência da integração dos processos de eletroflotação e filtração granular descendente no tratamento de água de produção de petróleo, utilizando para isso um efluente simulado preparado pela mistura de água de torneira, óleo lubrificante e NaCl. Para este fim, primeiramente foram estudados em sistema piloto, os efeitos das variáveis operacionais: taxa de escoamento do efluente, densidade de corrente elétrica e concentração de NaCl para a otimização do processo de eletroflotação e, posteriormente, foi estudada a integração dos processos. O desempenho do sistema piloto foi determinado por meio da redução do teor de óleos e graxas (TOG) do efluente tratado. De acordo com os resultados obtidos, o processo de eletroflotação teve o seu melhor desempenho com uma taxa de escoamento do efluente de 62,0 m3m-2d-1, densidade de corrente elétrica de 80,0 A m-2 e concentração de NaCl de 7900 mg L-1. Nessas condições, o processo de eletroflotação apresentou uma redução do TOG inicial (361,88 mg L-1) de mais de 94 % (20,15 mg L-1) após 180 min de eletrólise. Com a integração dos processos estudados, obteve-se uma redução média do TOG do efluente de mais de 98 % (6,42 mg L-1) ao longo de 12 h de tratamento, com um consumo energético do reator eletroquímico de 1,47 kWh m-3. Os processos integrados demonstraram ser também eficientes na redução de outros poluentes do efluente, além do TOG. Foram reduzidos 99,88 % de turbidez, 99,12 % de cor aparente, 90 % da absorbância no UV a 254 nm e 40 % de carbono orgânico dissolvido. Esses resultados demonstram a eficiência da integração dos processos de eletroflotação e filtração granular descendente na redução do TOG do efluente estudado a níveis aceitáveis pelo Conselho Nacional do Meio Ambiente (CONAMA) (< 29 mg L-1) e encorajam a aplicabilidade dessa tecnologia como um processo de tratamento para a indústria petroquímica.<br> / Abstract : One of the main problems faced by the oil industry is related to the amount of produced water generated during the oil extraction process and, consequently, the final destination of this effluent, which must undergo treatment processes in order to meet the specifications for disposal in the oceans or injection into oil wells. Thus, the present research had as objective to evaluate the efficiency of the integration of the processes of electroflotation and down-flow granular filtration in the treatment of water of petroleum production, using a simulated effluent prepared by the mixture of tap water, lubricating oil and NaCl. For this purpose, the effects of the operational variables: effluent flow rate, electric current density and NaCl concentration for the optimization of the electroflotation process were first studied in a pilot system, and the integration of the processes was studied later. The performance of the pilot system was determined by reducing the oils and grease content (OG) of the treated effluent. According to the results obtained, the electroflotation process had its best performance with an effluent flow rate of 62.0 m3m-2d-1, electric current density of 80.0 A m-2 and NaCl concentration of 7900 mg L-1. Under these conditions, the electroflotation process showed a reduction of the initial OG (361.88 mg L-1) of more than 94 % (20.15 mg L-1) after 180 min of electrolysis. With the integration of the studied processes, a mean reduction of the OG of the effluent of more than 98 % (6.42 mg L-1) was achieved over a 12 hour treatment, with an energy consumption of the electrochemical reactor of 1.47 kwh m-3. The integrated processes have also been shown to be efficient in reducing other effluent pollutants besides OG. 99.88 % turbidity, 99.12 % apparent color, 90 % UV absorbance at 254 nm and 40 % dissolved organic carbon was reduced. These results demonstrate the efficiency of the integration of the processes of electroflotation and descending granular filtration in reducing the OG of the studied effluent to levels acceptable to the national council of the environment (CONAMA) (< 29 mg L-1) and encourage the applicability of this technology as a process for the petrochemical industry.
183

Susceptibilidade antimicrobiana em isolados bacterianos de amostras de água do sistema de abastecimento de água e dos efluentes líquidos em hospitais do Vale dos Sinos / Antimicrobial susceptibility in bacterial isolates of water samples from drinking water distribution system and liquid effluents at hospitals of the Sinos Valley

Matos, Julyana Sthéfanie Simões January 2017 (has links)
A disseminação das infecções associadas aos cuidados da saúde é complexa e multifatorial. Neste sentido, a abordagem da participação do ambiente na disseminação de bactérias, avaliando-se os efluentes líquidos, visa contribuir para melhor compreensão e definição das recomendações e políticas de controle dentro dos estabelecimentos de saúde. O objetivo deste trabalho foi avaliar a presença de bactérias E. coli, Pseudomonas sp., Klebsiella sp. e Staphylococcus sp. na água proveniente do Sistema de Abastecimento de Água (SAA) que chega aos hospitais localizados em um município da região do Vale dos Sinos e nos seus respectivos efluentes líquidos bem como a pesquisa dos genes blaSHV, blaTEM e blaCTX-M nos isolados encontrados no efluente. Os isolados foram triados por testes bioquímicos convencionais e posteriormente tiveram sua identificação confirmatória pela metodologia Maldi – TOF. A detecção dos genes blaSHV, blaTEM e blaCTX-M foi realizada nos isolados de E. coli, Pseudomonas sp. e Klebsiella sp. Obtiveram-se, nos efluentes pesquisados, 100 isolados. Destes isolados, 20/100 (20%) foram do gênero Klebsiella sp., 09/100 (9%) do gênero Staphylococcus sp., 05/100 (5%) do gênero Pseudomonas sp. e 09/100 (9%) foram E. coli. Evidenciou-se perfil de multirresistência em 70% dos isolados de E. coli, 41,66% dos isolados de K. variicola, 66,66% dos isolados de K. pneumoniae e 75% dos isolados de Pseudomonas sp. De 30 isolados avaliados para genes de resistência, quatro (04/30) apresentaram o gene blaSHV, três (03/30) apresentaram os genes blaSHV e blaTEM, seis (06/30) apresentaram o gene blaCTX-M e um isolado (01/30) apresentou os genes blaSHV e blaCTX-M. Na água do SAA foi encontrado um isolado do gênero Staphylococcus sp. sensível a todos os antimicrobianos testados. Nos efluentes dos pontos avaliados ocorreu a presença das bactérias potencialmente patogênicas e dos genes de resistência pesquisados. Portanto, este corpo d’água pode estar atuando na disseminação de fatores de resistência. / The spread of infections associated with health care is complex and multifactorial. In this sense, to approach the role of the environment in the bacterial dissemination, evaluating liquid effluents, aims to contribute to a better understanding and definition of recommendations and control policies within health facilities. The aims of this study was to evaluate the presence of E. coli, Pseudomonas sp., Klebsiella sp. and Staphylococcus sp. in the water samples from the Water Distribution System (WDS) that enter the hospitals located in a municipality in the Sinos Valley region and in their respective liquid effluents, as well as the blaSHV, blaTEM and blaCTX-M resistance genes in the effluent isolates. The isolates were screened by conventional biochemical tests and later confirmed by the Maldi - TOF methodology. Detection of the blaSHV, blaTEM and blaCTX-M genes was performed in E. coli, Pseudomonas sp. and Klebsiella sp. A hundred isolates were obtained at the effluents samples surveyed. Of these isolates, 20% were Klebsiella sp., 9% were Staphylococcus sp., 5% were Pseudomonas sp. and 9% were E. coli. A multidrug resistance profile was found in 70% of the E. coli isolates, 41.66% of the K. variicola isolates, 66.66% of the K. pneumoniae isolates and 75% of the Pseudomonas sp. isolates. In the 30 isolates evaluated for the resistance genes, four had the blaSHV gene, three had the blaSHV and blaTEM genes, six had the blaCTX-M gene and one isolate presented the blaSHV and blaCTX-M genes. In the WDS water, a Staphylococcus sp. was found and it was sensitive to all tested antimicrobials. At the effluent from the evaluated points, the presence of potencial patogenic bacteria and the resistance genes studied were observed. Therefore, it might be taking part in the dissemination of resistant factors in this environment.
184

Avaliação do reúso agrícola na adequação de efluentes domésticos urbanos aos padrões da resolução 357/05 do CONAMA: esudo de caso da cidade de Sto. Antônio - BA

Medeiros Netto, Rogério de 15 March 2011 (has links)
Submitted by LIVIA FREITAS (livia.freitas@ufba.br) on 2015-12-04T15:06:36Z No. of bitstreams: 1 Disertação MEAU Rogério de Medeiros Netto.pdf: 36176323 bytes, checksum: 9e35834fd5bb96e036a09daf7cc53bdb (MD5) / Approved for entry into archive by LIVIA FREITAS (livia.freitas@ufba.br) on 2016-01-11T19:00:44Z (GMT) No. of bitstreams: 1 Disertação MEAU Rogério de Medeiros Netto.pdf: 36176323 bytes, checksum: 9e35834fd5bb96e036a09daf7cc53bdb (MD5) / Made available in DSpace on 2016-01-11T19:00:44Z (GMT). No. of bitstreams: 1 Disertação MEAU Rogério de Medeiros Netto.pdf: 36176323 bytes, checksum: 9e35834fd5bb96e036a09daf7cc53bdb (MD5) / Os crescentes problemas de escassez dos recursos hídricos, provocados pelo aumento da demanda em virtude do crescimento populacional e o comprometimento dos mananciais devido ao lançamento de esgotos, levaram a que o reúso da água voltasse a ser considerado. Outro fator que contribuiu para o desenvolvimento das práticas de reúso foi o maior rigor das legislações ambientais em relação ao padrão de qualidade dos efluentes. O estado da Bahia tem cerca de 70% de sua área incluída na região semiárida, onde habita, aproximadamente, a metade da população, sendo que pouco mais da metade em áreas urbanas. As condições climáticas e geológicas do semiárido fazem com que a maioria dos rios seja intermitente, os quais se caracterizam por não ter vazão nos períodos de estiagem, o que requer um nível alto de tratamento para que não haja poluição dos rios. Quanto maior o nível do tratamento, maiores são os custos, o que inviabiliza a adoção em grande escala. Os estudos tiveram por objetivo avaliar a eficiência do reúso agrícola, associado a um sistema de tratamento simplificado e de baixo custo de implantação e operação, como estratégia de redução da poluição de rios localizados em regiões semiáridas. Para tanto, implantou-se um sistema de tratamento simplificado, composto por um conjunto fossa-filtro, na cidade de Sto. Antônio,situada na região nordeste do estado da Bahia a 250 Km de Salvador e sede de um dos distritos do município de São Domingos. O efluente do sistema de tratamento foi aplicado num sistema de irrigação, composto de 8 sulcos com 30m de extensão. Embaixo da linha de plantio foram instalados drenos, a 0,6m e a 1,2m de profundidade para captar efluente infiltrado no solo e submetê-lo a análise laboratorial. Como não houve retenção de efluente nos drenos, procedeu-se a análise do solo para verificar eventuais alterações devido ao lançamento de efluentes. Os parâmetros analisados foram Matéria Orgânica. Fósforo Total e Nitrogênio Amoniacal. Os resultados indicam que o sistema solo-planta foi capaz de remover a matéria orgânica, bem como o Nitrogênio Amoniacal e o Fósforo. A remoção dos parâmetros analisados indica que o reúso agrícola pode ser uma ferramenta a ser utilizada na Gestão dos Recursos Hídricos, sobretudo em regiões semiáridas. As análises de Condutividade Elétrica e de Sólidos Dissolvidos no efluente tratado indicaram que o efluente tem um potencial elevado de provocar salinização no solo.
185

A interferência de diferentes níveis de radiação solar no tratamento de esgoto sanitário em lagoas de alta taxa

ALVES, Luna Gripp Simões January 2012 (has links)
Submitted by Teresa Cristina Rosenhayme (teresa.rosenhayme@cprm.gov.br) on 2015-02-25T13:43:17Z No. of bitstreams: 1 Dissertacao Luna .pdf: 1413009 bytes, checksum: 9a836f2438a7905278719c4f5729b62b (MD5) / Approved for entry into archive by Roberta Silva (roberta.silva@cprm.gov.br) on 2015-07-06T12:17:24Z (GMT) No. of bitstreams: 1 Dissertacao Luna .pdf: 1413009 bytes, checksum: 9a836f2438a7905278719c4f5729b62b (MD5) / Approved for entry into archive by Roberta Silva (roberta.silva@cprm.gov.br) on 2015-07-06T12:17:55Z (GMT) No. of bitstreams: 1 Dissertacao Luna .pdf: 1413009 bytes, checksum: 9a836f2438a7905278719c4f5729b62b (MD5) / Made available in DSpace on 2015-07-06T12:33:09Z (GMT). No. of bitstreams: 1 Dissertacao Luna .pdf: 1413009 bytes, checksum: 9a836f2438a7905278719c4f5729b62b (MD5) Previous issue date: 2012
186

Avaliação do desempenho de embarcações recolhedoras de óleo, em áreas de exploração e produção de petróleo

Carvalho, José Augusto de January 2013 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2013. / Made available in DSpace on 2014-08-06T17:10:46Z (GMT). No. of bitstreams: 1 321855.pdf: 1111860 bytes, checksum: 025f6bb7bea3b8d25a041c231f2bb2cd (MD5) Previous issue date: 2013 / Sabe-se que a necessidade mundial de consumo do Petróleo vem aumentando, consecutivamente também cresce o processo de pesquisa e sua produção. Vivemos um momento especial, onde estamos presenciando a exploração de Petróleo no chamado Pré Sal, caracterizado por estar em grande profundidade. Esta tecnologia ainda não está completamente dominada e tem uma grande expectativa sobre as possíveis consequências resultantes deste processo de exploração e produção. Além das grandes profundidades, existem produções próximas à costa, inclusive com áreas ambientais sensíveis. Este trabalho buscou avaliar os principais impactos ambientais gerados pelas embarcações dedicadas ao combate de vazamento de óleo no mar, que são as ?Embarcações Recolhedoras de Óleo?. Sabendo-se que atualmente essas embarcações ficam dedicadas nas proximidades dos locais de Exploração e Produção de Petróleo, navegando 24 horas por dia. Partindo deste princípio, foi pesquisado e calculado o consumo de óleo diesel e o quantitativo de emissão de poluentes atmosféricos, gerados por este consumo, necessários para o funcionamento das máquinas, como os motores, compressores e geradores. Ainda sobre esta navegação contínua, são apontados os principais acidentes ocorridos e a quantidade de óleo vazado no mar, com intuito de demonstrar que este trânsito contínuo dos barcos gera riscos de acidentes, com potencial de poluição ambiental. Além dos impactos ambientais, este trabalho demonstra os custos desprendidos para operação destas embarcações. Também foi analisado o acidente ocorrido no Golfo do México em 2010, na Plataforma da BP Deepwater Horizon Oil spill. Os dados apresentados demonstraram que houve um vazamento de 4,9 milhões de barris de óleo no mar, e que a capacidade efetiva de recolhimento foi de 20%, então cerca de 980 mil barris foram capturados, ficando o restante 3,92 milhões de barris sem recolhimento. Basta analisar os recursos demandados para atender o incidente da BP, em Macondo, no Golfo do México, para perceber que toda essa estrutura subutilizada se torna pequena em um evento como esse.Para que as embarcações permaneçam navegando em alto mar, um grande consumo de combustível é necessário para o funcionamento de seus motores propulsores. Foi apurado que anualmente são consumidos cerca de 81.600 m3 de combustível, resultando em uma emissão aproximada de 219 milhões de quilos de CO² na atmosfera. Além disso,verificou-se que são gerados 228.480 litros de águas residuais, que são destinadas em alto mar, muitas vezes sem o tratamento adequado.Como reflexão final, levantou-se a questão sobre o que é mais impactante ao meio ambiente: a estrutura de resposta dedicada a vazamentos de óleo, exigida e aprovada pelo IBAMA; ou os danos causados pelos eventuais derrames de óleo oriundos das operações de exploração e produção de petróleo. <br> / Abstract : It is known that the world oil consumption need is increasing, and thus the research process and its production also increases. We live in a very special moment, in which we are witnessing the Oil Drilling in the so called pre-salt layer, characterized by the fact that it is located in a high depth. This technology is not completely dominated and exercises a large expectation on the possible consequences arising of mentioned exploration and production process. Besides the high depths, there also exist production sites next to the coast, including areas which are environmentally sensible.Present work tried to evaluate the main environmental impacts caused by the vessels dedicated to the oil spilling response in the sea, which are the ?Oil Recovery Vessels?. It is known that these vessels stay at disposal in the proximity of the Oil Exploration and Production Sites, navigating 24 hours per day. Starting from mentioned principle, the diesel oil consumption, as well as the atmospheric pollutant emission quantitative generated by such consumption, which is necessary for the functioning machine such as motors, compressors and generators, were duly researched and calculated. Still referring to mentioned continuous navigation, we also indicate the main accidents occurred and the quantity of oil released in the sea, with the purpose to demonstrate that such continuous vessel transit generates accident risks, presenting a potential for environmental pollution. Besides the environmental impacts, present work also demonstrates the costs arising of such vessel operation. The accident that took place in the Gulf of Mexico in 2010, in the BP Platform Deepwater Horizon Oil spill, has also been analyzed. The presented data demonstrate that there occurred a spill of 4.9 million oil barrels in the sea, and that the effective cleanup and recovery was of 20%, having approx. 980 barrels been captured, whereas the remaining 3.92 million barrels have not been recovered. It is only necessary to analyze the resources required to attend the BP incident in Macondo, in the Gulf of Mexico, to perceive that all such underused structure gets small in such an event.For sailing vessels remain at sea, a large consumption of fuel is needed for the operation of their engines propellers. It was found that annually are consumed approximately 81,600 m3 of fuel, resulting in the issuance of approximately 219 million pounds of CO ² in the atmosphere. Furthermore, it was found that 228 million liters are generated wastewater, which are aimed at sea, often without treatment.As a final reflection has been raised the question on what is more impacting to the environment: an answering structure dedicated to oil spills required and approved by IBAMA; or the damages caused by eventual oil spills arising of the oil exploration and production operations.
187

Estudo da evaporação como tecnologia aplicada ao pré-tratamento de lixiviados de aterros sanitários

Moratelli, Letícia January 2013 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2013. / Made available in DSpace on 2014-08-06T17:23:55Z (GMT). No. of bitstreams: 1 321649.pdf: 3027993 bytes, checksum: 325522b91241ad07e3c9c1e61fe3cc02 (MD5) Previous issue date: 2013 / A utilização de aterros sanitários para o tratamento e disposição de resíduos sólidos urbanos traz inúmeras vantagens, entretanto, apresenta como desvantagem a produção de lixiviado, líquido proveniente da degradação da matéria orgânica presente nos resíduos, bem como da água de infiltração que percola nas camadas de resíduos do aterro sanitário. Em geral, o lixiviado é constituído de poluentes orgânicos, inorgânicos, metais-traço e grupos microbianos, sendo necessário seu tratamento antes de ser lançado em corpos hídricos receptores e/ou ser disposto no solo. O tratamento dos lixiviados pode ser realizado através de processos biológicos ou físico-químicos, ou ainda uma combinação destes dois processos, tendo como objetivo a redução do potencial poluidor deste líquido. No que diz respeito à redução da quantidade de lixiviado a ser tratada, existem, dentre outras técnicas, a recirculação do líquido no próprio aterro sanitário e, mais recentemente, a evaporação da água presente neste efluente. Este trabalho teve como objetivo estudar o processo evaporativo, em escala piloto, utilizando-se uma torre de resfriamento ajustada para a evaporação de lixiviado. Foram avaliadas, através de análises estatísticas, as eficiências de evaporação obtidas, a partir da variação de parâmetros operacionais e, ainda, verificada a influência das condições meteorológicas no processo. No que diz respeito à avaliação ambiental, foi verificada a qualidade do concentrado, produto resultante da evaporação, por meio da caracterização físico-química do lixiviado bruto e do residual do processo ao longo do período de experimentação, assim como determinado o perfil das populações bacterianas dos diferentes extratos de análise, através de técnicas morfológicas e de biologia molecular. A eficiência de evaporação na unidade piloto foi afetada pelas condições meteorológicas analisadas ? radiação solar, velocidade do vento, umidade relativa e temperatura média do ar. Através da avaliação da influência da massa inicial, da vazão de recirculação de lixiviado e da velocidade do ar aplicada ao sistema pode-se verificar que apenas a vazão de lixiviado influenciou as taxas evaporativas. A velocidade do ar foi significativa quando analisadas, somente, altas (5,5 e 6,0 m.s-1) e baixas velocidades (0,5 e 1,0 m.s-1). O processo evaporativo concentrou a maior parte dos poluentes presentes no líquido remanescente (sólidos, matéria orgânica, nitrato, etc.), enquanto que as concentrações de NTK e de nitrogênio amoniacal foram reduzidas. Pelas análises de PCR e DGGE, em amostras de lixiviado bruto e concentrado, observou-se a seleção de grupos filogeneticamente similares, quando os mesmos foramsubmetidos ao processo evaporativo. Foram observados, através da análise de BOX-PCR, cinco agrupamentos distintos nas amostras de ar, coletadas no entorno da unidade piloto. No duto de saída da unidade experimental houve maior número de UFC.m-3, em relação aos outros locais de amostragem, sugerindo que ocorreu a emissão de bactérias durante o processamento do lixiviado na unidade experimental. <br> / Abstract : The use of landfills for the treatment and disposal of municipal solid waste brings numerous advantages, however, has the disadvantage of producing leachate, which is the liquid generated from the degradation of organic matter present in the waste and due to infiltration water that percolates through layers of waste in the landfill. In general, leachate contains organic and inorganic pollutants, heavy metals and microbial groups, requiring treatment before being released into receiving water bodies and/or be disposed in the ground. The leachate treatment can be accomplished through biological or physico-chemical processes, or a combination of these, with the objective of reducing its pollution potential. In regard to the reduction of the quantity of leachate to be treated, there are, among other techniques, recirculating liquid in the landfill itself, and more recently the evaporation of water contained in this effluent. This work aimed to study the evaporative process in a pilot plant scale, using a cooling tower adapted for leachate evaporation. Evaporation efficiencies were evaluated through statistical analysis, taking into account the variation in operating parameters, and also via the influence of the weather conditions. Regarding environmental evaluation, it was verified the quality of the concentrate material from evaporation, done by physico-chemical characterization of raw and residual product over the experimental period, and determined the profile of bacterial populations by morphological and molecular biology techniques. Evaporation efficiencies in the pilot plant were affected by weather conditions ? solar radiation, wind speed, relative humidity and air temperature. The initial leachate mass, recirculation flow rate and the air speed applied to the system influenced only on the flow of the leachate evaporation rates. The airspeed had a significant effect only when analyzed on the highest (5,5 and 6,0 m.s-1) and lowest (0,5 and 1,0 m.s-1) speeds. The evaporative process concentrate most of the pollutants present in the remaining liquid (solids, organic matter, nitrate, etc.), while the concentrations of ammonia and NTK has been reduced. The PCR and DGGE techniques carried out for the raw leachate and concentrated samples recovered phylogenetically similar groups during the evaporative process. Five different bacterial grouping were identified by BOX-PCR in air samples collected in the vicinity of the pilot unit. A greater number of CFU.m-3 was identified in the outlet duct of the experimental unit compared to other sampling sites, suggesting that these microorganisms may have come from the processing of the leachate in the pilot plant.
188

Avaliação da descoloração e da biodegradabilidade de efluentes têxteis pelo processo UVC/H2O2 como etapa de polimento ao tratamento biológico

Novack, Aline Mara January 2016 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Química, Florianópolis, 2016. / Made available in DSpace on 2016-09-20T04:36:58Z (GMT). No. of bitstreams: 1 339942.pdf: 1143108 bytes, checksum: 4dadb715090523b268d69cf8e7af04ff (MD5) Previous issue date: 2016 / O processamento de produtos têxteis envolve diferentes etapas, tais como o branqueamento, tingimento, estampagem e compactação, que conduzem à geração de águas residuárias de elevada resistência com uma cor intensa . As águas residuárias têxteis são caracterizadas pela presença de uma ampla variedade de corantes e produtos auxiliares. A remoção de cor a partir de águas residuárias têxteis representa uma grande preocupação ambiental. A remoção da cor de dois efluentes têxteis reais diferentes, previamente oxidados biologicamente, foi avaliada através de um sistema de oxidação fotoquímica UVC/H2O2. Os experimentos foram realizados em um fotorreator tubular em escala laboratorial, em que um tubo de borossilicato está associado a um tubo de quartzo concêntrico interno que contém uma lâmpada UVC (6W) alocado no foco dos dois refletores de aço inoxidável. A velocidade de reação foi avaliada sob diferentes condições operacionais: dosagem de H2O2 (0-39 mM), pH (3,0; 5,0 e 9,0) e temperatura (15, 23 e 35 ° C). Para atingir os limites de descarga de cor impostos pelas normas brasileiras, foi necessário 120/90 minutos de radiação UVC (9,7-4,0 kJUVC L-1), utilizando uma dose de 25 mM H2O2 para ambos, pH natural de 8,1 - 7,7 e temperatura de 23 °C, para o efluente A / B, respectivamente. Embora o teor de matéria orgânica dissolvida permaneça praticamente constante durante as reações UVC/H2O2, a fração orgânica biodegradável aumentou para valores superiores a 40% de acordo com o teste de Zahn-Wellens. Os resultados obtidos neste trabalho mostraram que o processo de oxidação UVC/H2O2 foi adequado para reduzir a cor de dois efluentes têxteis reais de acordo com os limites de descarga estabelecidos na legislação brasileira.<br> / Abstract: The processing of textile fabrics involves different steps such as bleaching, dyeing, printing and stiffening, leading to the generation of high strength wastewaters with an intense colour. The textile wastewaters are characterized by the presence of a wide variety of dyes and auxiliary products. The removal of colour from textile wastewaters represents a major environmental concern. The decolourisation of two different bio-treated real textile wastewaters was evaluated through a photochemical UVC/H2O2 oxidation system. The photochemical experiments were performed in a lab-scale tubular photoreactor, where a borosilicate tube is associated to an internal concentric quartz tube containing a UVC lamp (6W) allocated in the focus of two stainless steel reflectors. The reaction rate was evaluated under different operational conditions: H2O2 dosage (0- 39 mM), pH (3.0, 5.0 and 9.0) and temperature (15, 23 and 35 °C). To achieve the colour discharge limits imposed by the Brazilian regulations, it was necessary 120/90 min of UVC irradiation (9.7-4.0 kJUVC L-1) using an H2O2 dose of 24.5 mM for both, natural pH of 8.1 - 7.7 and temperature of 23 °C, respectively for the wastewaters A / B. Although the dissolved organic content remained almost similar during the UVC/H2O2 oxidation, the biodegradable organic fraction increased for values higher than 40% (Zahn-Wellens test). The results of this work proved the UVC/H2O2 oxidation system was able to achieve the decolourisation of the bio-treated real textile wastewaters in agreement with the Brazilian discharge limits.
189

Avaliação da produção de biogás para fins energéticos em reatores anaeróbios tratando esgoto sanitário

Cabral, Carolina Bayer Gomes January 2016 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-graduação em Engenharia Ambiental, Florianópolis, 2016. / Made available in DSpace on 2016-10-11T04:02:25Z (GMT). No. of bitstreams: 1 342216.pdf: 4903930 bytes, checksum: 1fc2c99e8741f3c06ecb224e2cea7e83 (MD5) Previous issue date: 2016 / O aproveitamento energético do biogás é uma maneira de minimizar as emissões de gases de efeito estufa, como o gás metano, e explorar uma fonte de energia renovável. A utilização do biogás gerado no tratamento de efluentes líquidos em reatores anaeróbios tipo UASB, se integra nessa proposta de boa prática em ETE. A melhoria na eficiência energética e aproveitamento de biogás em sistemas de tratamento com reator UASB dependem de um maior conhecimento sobre o comportamento da produção de biogás e de medidas no âmbito construtivo e operacional. Neste contexto, o objetivo geral desse estudo foi avaliar o potencial de geração de biogás para fins energéticos em reatores anaeróbios tipo UASB/RALF em escala plena a partir de medições Os objetivos específicos deste trabalho foram: a) Analisar em tempo real a vazão e composição do biogás; b) Estabelecer as relações unitárias de produção específica de biogás para cada ETE e correlacionando-as com as condições operacionais e ambientais; c) Estimar o potencial de geração de energia. Para atingir os objetivos propostos foram realizadas medições em seis estações de tratamento de esgoto durante doze meses através de medidores online das concentrações de DQO, das vazões de esgoto e de biogás, e da qualidade do biogás. Os resultados mostraram que para reatores UASB a concentração de metano média variou de 70 a 80%, CO2 de 6 a 12% e de H2S de 1300 a 2100 ppm, e que estas não sofreram grandes variações durante o ano. A vazão de biogás teve um comportamento periódico e variável de acordo com as diferentes condições operacionais, apresentando redução após eventos significativos de chuva. De maneira geral as relações unitárias de produção de biogás apresentaram valores inferiores ao esperado, indicando perdas de biogás. Os valores obtidos variaram de 81 a 142 NL de CH4/kgDQOrem, com eficiências de remoção de DQO de 63 a 88%. Os reatores com boa vedação atingiram valores de produção específica de biogás de 17 l/hab.d, 89 l/m3 de esgoto e 179 l/kg DQOremovida. A geração de energia elétrica específica para esse caso foi de 17,8 kWh/hab.ano. As demais estações apresentaram valores inferiores devido a maiores perdas de biogás.<br> / Abstract : The energy recovery of biogas is way of minimizing the greenhouse gas emissions such as methane and explore a renewable energy source. The use of the biogas generated by wastewater anaerobic treatment in UASB reactors integrates in this proposal of good practices in WWTP. The energy efficiency improvement and the recovery of biogas in WWTP with UASB reactors depend of a better knowledge of the biogas production behavior and of constructional and operational measurements. The specific aims of this study were a) To quantify the biogas flow and composition; b) To establish unitary yields of specific biogas production for each WWTP, correlating them to the operational and environmental conditions; c) To estimate the energy potential of each WWTP analyzed. In order to achieve this goals, six wastewater treatment plants with UASB reactors were monitored during 12 months by online measurements of COD, wastewater and biogas flow, and biogas quality. The results showed that the average CH4 concentration ranged from 70 to 80%, the CO2 from 6 to 12% and the H2S from 1300 to 2100 ppm, and didn?t show much variation during the year. The biogas flow had a periodic and variable behavior according to the different operational conditions, decreasing after heavy rainfall. In general, the specific biogas production yields were lower than expected, indicating biogas losses. The values obtained ranged from 81 to 142 NL of CH4/kgCODremoved and the COD removal efficiencies from 63 to 88%. The well sealed reactors achieved biogas production yields of 17 L/inhab.day, 89 L/m3wastewater e 179 l/kg CODremoved. In this case, the unitary electrical energy potential was 17,8 kWhel/inhab.year. The others WWTP presented lower values due to higher biogas losses.
190

Ficorremediação de efluentes da suinocultura: efeitos da composição do substrato e dos nutrientes (N e P) na composição química das microalgas

Michelon, William January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Química, Florianópolis, 2015. / Made available in DSpace on 2016-10-19T12:55:10Z (GMT). No. of bitstreams: 1 338960.pdf: 1255271 bytes, checksum: 64a9e5455dbcf43db4a59b3a33b12660 (MD5) Previous issue date: 2015 / A suinocultura é uma importante atividade social e econômica para todo o país, entretanto, esta atividade é reconhecida por causar problemas ambientais significativos. O tratamento de águas residuárias por processo de ficorremediação está atraindo o interesse renovado devido às suas potenciais aplicações da biomassa para produção de biocombustíveis e compostos de alto valor, agregando valor econômico ao agronegócio. A presente pesquisa teve como objetivo avaliar a remoção de nutrientes dos efluentes do UASB (Upflow Anaerobioc Sludge Blanket) e sistema de lodos ativados (LA) de um processo de tratamento de dejetos suínos por ficorremediação, e a composição química celular. O cultivo foi realizado em escala laboratorial com fotobiorreatores verticais (FBRs) com luminosidade artificial (44,8 mmol m-2 s-1) temperatura de 23 ºC e escala piloto numa casa de vegetação sob a luz natural, com intensidade luminosa variando de 90-733 µmol m-2 s-1 e temperatura ambiente com variação de 15,4-48 ºC, utilizando consórcio com Chlorella spp. e Scenedesmus spp. A biomassa foi coletada por centrifugação e precipitação química usando polímero orgânico catiônico (tanino). A eficiência de remoção para a amônia foi de 44,3 e 76,7% com efluente do UASB e LA, respectivamente. A eficiência da remoção de fósforo da cultura com UASB alcançou 89,6%, em contraste, com LA foi de 76,5%, após 96h de ficorremediação. A biomassa colhida a partir do efluente do UASB apresentou 56,1, 34,4 e 1,1% de proteínas, carboidratos e lipídios, respectivamente. Comparativamente, a composição celular das microalgas cultivadas com efluente LA teve diminuição nas proteínas (44%) mas os teores de carboidratos foram mais elevados (41,9%) e não houve diferença nos teores de lipídios (2%). No entanto, a biomassa separada por centrifugação os níveis foram de 25,2, 58,9 e 3% em carboidratos, proteínas e lipídios, respectivamente. Quando privadas de nutrientes (N e P) o teor de carboidratos foi de 56,8%, proteínas 22% e lipídios 16,3%. Os resultados demonstraram que a amônia e fósforo foram satisfatoriamente removidos. Biomassas de microalgas a partir de processos de tratamento terciário são ricos em proteínas e carboidratos, mas com baixo teor de lipídios. O processo de colheita pode alterar a composição química. A privação de nutrientes aumenta a acumulação de lipídios no interior das células e são ricas em ômega 3 e 6.<br> / Abstract : The swine is an important social and economic activity for the whole country, however, this activity is known to cause significant environmental problems, the treatment of wastewater by phycoremediation process is attracting renewed interest due to their potential applications of biomass production biofuels and high value compounds, adding economic value to agribusiness. This research aimed at evaluating the removal of nutrients from the effluent UASB (Upflow Sludge Blanket Anaerobioc) and AL system (Activated sludge) of a treatment process of swine manure by phycoremediation, and cellular biochemical composition. Cultivation was carried out in laboratory scale with vertical photobioreactors (PBRs) with artificial light (44.8 mmol m-2 s-1) temperature of 23 ° C and pilot scale reactor in greenhouse indoors under natural light with luminous intensity ranging from 90-733 µmol m-2 s-1 and room temperature ranging from 15.4-48 ° C using polyculture with Chlorella sp. and Scenedesmus sp. The biomass was collected for centrifugation and chemical precipitation using cationic organic polymer (tannin). The removal efficiency for ammonia was 44.3 and 76.7% with effluent from the UASB and LA, respectively. The efficiency of phosphorus removal of the culture with UASB reached 89.6%, in contrast with the LA was 76.5% after 96h of phycoremediation. The efficiency of phosphorus removal of the culture with UASB reached 89.6%, in contrast with the LA was 76.5% after 96h of phycoremediation. The harvested biomass from the UASB effluent showed 56.1, 34.4 and 1.1% protein, carbohydrates and lipids, respectively. Comparatively, the cellular composition of cultivated microalgae with LA effluent had decreased in protein (44%) but the carbohydrate content was higher (41.9%) and no difference in lipid content (2%). However, the biomass separated by centrifugation levels were 25.2, 58.9 and 3% of carbohydrates, proteins and lipids, respectively. When starved the carbohydrate content was 56.8%, proteins 22% and lipids 16.3%. The results showed that ammonia and phosphorus have been removed satisfactorily. Biomass of microalgae from tertiary treatment processes are rich in protein and carbohydrates, but low in lipids. The process of crop can change the biochemical composition. The nutrient deprivation increases the accumulation of lipids within cells and are rich in omega 3 and 6.

Page generated in 0.0709 seconds