• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 619
  • 7
  • 6
  • 6
  • 6
  • 6
  • 4
  • 2
  • Tagged with
  • 643
  • 643
  • 342
  • 221
  • 167
  • 144
  • 127
  • 107
  • 92
  • 84
  • 80
  • 77
  • 76
  • 67
  • 66
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

Desempenho de reator anaerobio de manta de lodo utilizando efluentes liquidos de industria alimenticia

Nascimento, Rosilene Aparecida 14 February 1996 (has links)
Orientador: Roberto Feijo de Figueiredo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-21T13:13:33Z (GMT). No. of bitstreams: 1 Nascimento_RosileneAparecida_M.pdf: 3066044 bytes, checksum: b01db73c88a40cbf52ea40e623266ecd (MD5) Previous issue date: 1996 / Resumo: Devido às vantagens oferecidas pelo processo de digestão anaeróbia em tratamento de efluentes líquidos, sobretudo pelo baixo volume de Iodo gerado quando comparado ao tratamento aeróbio, vários autores dirigem seus estudos com o intuito de dominá-Ia. Porém, trata-se de um processo complexo de degradação e susceptível às variações das condições ambientais, como pH, temperatura, concentração de substratos e de produtos tóxicos pode comprometer a eficiência processo. O reator anaeróbio de um sistema de tratamento de efluentes de uma indústria alimentícia, com principal atividades a produção de biscoitos, foi utilizado como objeto de estudos. O processo anaeróbio foi monitorado durante três meses após a interrupção da alimentação do reator por dois meses, utilizando parâmetros como vazão, temperatura, pH, alcalinidade de bicarbonatos, relação entre alcalinidade intermediária e parcial, demanda química de oxigênio - DQO e carbono orgânico dissolvido - eOD. Além desses, são apresentados os dados operacionais obtidos pela indústria para o período de setembro de 1994 a novembro de 1995. Os parâmetros DQO e eOD afluentes ao reator foram comparados e apresentaram grau de correlação igual a 0,78. A carga orgânica volumétrica média aplicada durante o monitoramento foi de 0,8kgDQO m-3d-1e o reator respondeu com eficiência média de 87% em remoção de DQO... Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: Many research projects are being developed with the objective of understanding the anaerobic process to treat wastewater. This process has a great advantage of producing small sludge volumes, but, on the other hand, it is very complex, and environmental changes, measured as pH, temperature, substrate concentration and toxic products may affect the whole process efficiency. In this study an anaerobic reactor from a food industry treatment plant was utilized. Manufactured products from a food industry inciude cookies crackers and candies. Anaerobic process was monitored for three months, after a two-month no feed period. Major measured parameters were: flowrate, temperature, pH, bicarbonate alkalinity, chemical oxigen demand (COO), and dissolved organic carbon (OOC), as well as the relationship between intermediate and partial alkalinities. Also, operational data obtained by the industry for the period September 94 - November 95 are presented. Influent COO and OOC values were compared and results indicated an correlation of 0.78. The average volumetric organic load during experiment was O.8kgCOOm-3d-1,and COO removal was 87 percent... Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Recursos Hidricos e Saneamento / Mestre em Engenharia Civil
222

Estudo do tratamento de aguas residuarias sinteticas por lodo ativado em reator batelada sequencial com tempo longo de duração

Parente, Ana Catarina Gomes 16 February 1998 (has links)
Orientador: Ranulfo Monte Alegre / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-07-23T09:27:20Z (GMT). No. of bitstreams: 1 Parente_AnaCatarinaGomes_M.pdf: 3129195 bytes, checksum: 4ec831904e09767661681a08cf4e8f4b (MD5) Previous issue date: 1998 / Resumo: O processo de tratamento de águas residuárias por lodo ativado em reator batelada seqüencial (RBS) apresenta várias vantagens: grande flexibilidade de operação; é apropriado para tratar efluentes com variação de carga hidráulica e orgânica e apresentam excelente razão custo/benefício, razões pelas qual o interesse por sua utilização tem aumentado nos últimos anos. No presente trabalho estudou-se o tratamento de águas residuárias sintéticas por lodo ativado em reator RBS, com longo tempo de aeração, após completado o volume final do reator. Observou-se que houve aumento da concentração de sólidos suspensos na fase de alimentação do reator e diminuição na fase aerada sem alimentação (25 a 45 horas). Em vários experimentos a concentração final de sólidos foi menor que a inicial; porém, como o volume final foi o dobro do inicial, a massa final de sólidos sempre foi maior que a inicial. Em dois pares de experimentos foi necessário descartar sólidos antes de iniciar novo experimento. Houve casos em que a concentração da Demanda Química de Oxigênio (DQO) aumentou no final da etapa aerada sem alimentação, provavelmente como conseqüência de ter ocorrido respiração endógena e autólise celular. Foram utilizadas três concentrações de alimentação de DQO (2464,67; 3365,379 e 5245,456 mg/l) e a concentração final de sólidos suspensos, concentração final de DQO, pH e índice volumétrico de lodo (IVL) variaram de 808,70 a 3478,72; 117,31 a 833,33 mg/l; 6,2 a 7,8 e 15,63 a 70,27 g/ml respectivamente. A taxa específica de crescimento celular na fase de alimentação apresentou valores altos e uma grande variação (0,095 a 0,392 h-1), devido ao fato de que nesta fase a fração mais biodegradável do substrato foi consumida rapidamente. A constante de velocidade de redução de DQO também apresentou valores altos na fase de alimentação (0,17 a 4,94 h-1), como conseqüência da alta velocidade de consumo de substrato e o modelo proposto de primeira ordem não ter apresentado bom ajuste. Na fase aerada sem alimentação, a constante de velocidade de redução de DQO variou de 0,003 a 0,146 h-1 e o coeficiente de morte celular de 0,003 a 0,062 h-1, sendo a maior eficiência de redução de DQO obtida de 93,52 % com vazão de alimentação de 264 ml/h, concentração de alimentação de DQO de 3365,379 mg/l em 50 horas de tratamento / Abstract: The use of activated sludge in sequential batch reactors (SBR's) for wastewater treatment has been a subject of growing interest in the last few years due to the advantages it shows over other currently employed processes. It is only suitable for treating streams with variations in both the flow rate and organic load, and also presents a high operation flexibility as well as an excellent cost/efficiency ratio. In the present work activated sludge in SBR's was employed to study synthetic wastewater treatment with long aeration time, typically 25 to 45 hours, after reactor feeding. It was observed an increase in the suspended solids concentration at the end of the aerated feed stage, accompanied by its decrease during the aeration stage without feed. In many experiments the final concentration of suspended solids was lower than that measured at the beginning but, as the final volume was twice the initial one, the final mass of suspended solids was always higher. Moreover, in four experiments, it was necessary to discharge the excess of activated sludge before starting a new set of experiments. Also, in some cases, there was an increase in the chemical oxygen demand (COD) levels at the end of the aeration stage, probably due to endogenous respiration and cellular autolysis. For three different COD levels of feeding (2,464.67; 3,365.379 and 5,245.456 mg/l), the final concentration of suspended solids, final COD level, pH and sludge volume index (SVI) varied between 808.70 and 3,478.72 mg/l, 117.31 and 833.33 mg/l, 6.2 and 7.8, and 15.63 and 70.27 g/ml, respectively. The specific growth rate in the feed stage showed high values as well as a large variation (0.095 to 0.392 h-1) due to the fact that, in this stage, the most biodegradable substrate fractions were quickly consumed. Similarly, high values for the COD reduction rate constant in the feed step (0.17 to 4.94 h-1) were observed, as a consequence of rapid substrate consumption and the fact that the first order mathematical model, chosen previously to describe the process, did not prove to be suitable. In the aeration stage without feed, the COD reduction rate constant varied between 0.003 and 0.062 h-1, while the cellular decay constant was in the range of 0.003 to 0.062 h-1. The highest efficiency value for the COD reduction (93.52%) was observed for a flow rate of 400ml/h and a COD of 3,365.739 mg/l after 50 hours of treatment / Mestrado / Mestre em Engenharia de Alimentos
223

Estudos de viabilidade do reuso de efluentes liquidos gerados em processos de galvanoplastia por tratamento fisico-quimico

Carrara, Silvia Marta Castelo de Moura 13 March 1998 (has links)
Orientador: Ruben Bresaola Jr / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-23T10:46:15Z (GMT). No. of bitstreams: 1 Carrara_SilviaMartaCastelodeMoura_M.pdf: 4303374 bytes, checksum: 6a07d3d00fb4c6be5d88fd89742e5773 (MD5) Previous issue date: 1997 / Resumo: Os despejos industriais dos processos de galvanoplastia causam, em geral, graves problemas de poluição hídrica por conterem metais pesados e utilizarem grandes volumes de água em seus processos. A reciclagem ou reuso dos efluentes para fins diversos pode diminuir a demanda de água dos mananciais e minimizar a quantidade de efluentes lançados nas redes públicas de esgotos ou rios. O presente trabalho tem por objetivo estudar a viabilidade do reuso ou reciclagem das águas residuárias geradas em indústrias de galvanoplastia, por meio de tratamento fisico-químico de coagulação-floculação. Os resultados dos ensaios mostraram que houve remoção de metais acima de 99% utilizando-se NaOH com pH de coagulação igual a 10, com tempo de sedimentação de 90 minutos, ou utilizando-se 30 mg/L de cloreto férrico em pH 10 e também polímero aniônico em pH 9, ambos com tempo de precipitação de 60 minutos. Com isso, conclui-se que, com relação à quantidade de metais, estas águas apresentam teores inferiores aos limites estabelecidos para as águas de Classe 3, de acordo com a legislação CONAMA n. 20, podendo ser reutilizadas para irrigação de culturas arbóreas e forrageiras. Podem, igualmente, ser reutilizadas para lavagem de pisos, em descargas de banheiros e em alguns tanques do primeiro enxágüe das peças. Para reciclagem dessas águas no processo, toma-se necessária a diluição com água limpa para diminuição da condutividade da água tratada / Abstract: The industrial wastes of the galvanotechnick processes cause, in general, serious hydro pollution due to the use of heavy metaIs, besides that, they use great volumes of water in their processes. The recyc1ing or reuse of the waste for many purposes reduces the water demand of the rivers and minimizes the quantity wastes to be launched in the sewers or rivers. Due to these facts, the present work had the objective of studying the feasibility of the reuse or recyc1ing of residuary water generated in galvanotechnick industries by physical-chemical treatment of coagulation-flocculation. The results of the research had shown that there was removal of metaIs above 99% using NaOH with pH equal to 10, with precipitation time of90 minutes, or using FeCh ofpH 10 and also anionic polymer ofpH 9, both with time precipitation of 60 minutes. Therefore, it can be conc1udedthat in relation to the quantity of metaIs, this water can be reused for irrigation of garden culture, for pavement and toilet flush c1eaning. For recyc1ing of these water in process, it becomes necessary the dilution with c1eanwater for decrease of conductivity of treated water / Mestrado / Saneamento / Mestre em Engenharia Civil
224

Filtro anaerobico com enchimento de bambu para tratamento de esgotos sanitarios : avaliação da partida e operação

Camargo, Sandra Aparecida Rozon de 10 June 2000 (has links)
Orientador : Edson Aparecido Abdul Nour / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-27T20:20:15Z (GMT). No. of bitstreams: 1 Camargo_SandraAparecidaRozonde_M.pdf: 11794791 bytes, checksum: f1c322a56dacbfea9425a58f06aff3f1 (MD5) Previous issue date: 2000 / Resumo: Quatro filtros anaeróbios de fluxo ascendente com anel inteiro e meio anel de bambu, foram operados durante um periodo de 745 dias, com tempo de detenção hidráulico (TDH) inicial de 9 e 7 horas, em nível de escala piloto, para tratamento de esgoto sanitário, após tratamento preliminar, de uma das ETEs da cidade de Limeira - S.P. O término da partida dos reatores, com adição de inóculo proveniente de uma fossa séptica, foi entre 74 a 159 dias de operação, quando a percentagem de remoção ao redor de 60% de DQO e DBO foi atingida e a partir de então, não ocorreram variações significativas em tomo deste valor. Ao longo do tempo de monitoração dos filtros, a eficiência de remoção de DQO e DBO esteve na faixa de 60 a 80%, com maiores valores de remoção quando o afluente se encontrava mais concentrado. Também foi avaliado o desempenho de um dos filtros com diminuição gradativa no TDH (9 a 2 horas) e apresentou bom desempenho com baixo TDH. Aos 562 dias de operação houve um despejo ácido clandestino na rede coletora de esgoto, diminuindo o pH do afluente para 1,9 e resultando em quedas de remoção de aproximadamente 20%, 40%, 30% e 15% para DQO total, DQO filtrada, DBO e SST, respectivamente. Após 2 a 3 meses de operação, o desempenho dos filtros retomou aos valores obtidos antes do choque ácido, variando o tempo de recuperação para cada parâmetro e reator analisado, onde a remoção de DQO filtrada apresentou maior queda e menor capacidade de recuperação e o filtro, com menor TDH (2 horas), necessitou de maior tempo para retomar ao desempenho anterior ao choque ácido. Foi feito o estudo do comportamento hidrodinâmico dos filtros com água, utilizando NaCI como indicador e verificou-se que o escoamento real dos reatores apresentou tendência ao escoamento pistonado, que é caracterizado por apresentar variação na concentração na direção axial. Esse comportamento encontrado para os filtros comprova os resultados obtidos no estudo do desempenho em diferentes alturas, com variação na qualidade do efluente ao longo da altura dos filtros, com aumento de remoção de DQO e DBO nos efluentes coletados nas saídas laterais de O a 80 cm em relação ao fundo falso. Amostras de anéis inteiros e meio anéis de bambu foram analisadas, através do ensaio de compressão mecânica, verificando-se que a degradação do anel inteiro de bambu se estabilizou após o primeiro ano de operação dos filtros, com perda de resistência de 28,6% e 31,5% após 1 e 2 anos de uso, respectivamente / Abstract: Four pilot-scale uptlow anaerobic filters containing whole and half bamboo rings were operated with initial hydraulic retention times (HRT) of 9 and 7 hours, in the treatment of municipal wastewater. The start-up period conclusion, with addition of septic sewage seeding material, was between days 74 and 159 of operation, when COD and BOD removal efficiencies were on the order of 60%, what didn't change significant by afterwards. Along the time of filter monitoring, COD and BOD removal efficiencies were on the order of 60 to 80%, when the highest removal value occured when the influent was more concentrated. The performance of one filter was also evaluated with HRT decreasing values (9 at 2 hours), obtaining good performance with low HRT. In day 562 of operation an acid shock happened, decreasing the influent pH to 1.9, resulting in lower COD, BOD and SST removal efficiency of about 20%, 40%, 30%, and 15%, respectively. After 2 to 3 months of operation, the filters performance came back to the values obtained before the acid shock, varying the time of recovery for each parameter of the analyzed reactor, where the filtered COD removal rate was lower with less recovery capacity. The filter with smaller TDH (2 hours), needed longer time to come back to performance before acid shock. Also filters hydrodynamic behavior study with water was performed, using NaCI as a tracer. It was verified that the reactors real tlow presented a tendency to plug tlow, that is characterized by presenting variation of the concentration in the axial direction. That behavior found for the filters matches the results obtained in the different heights performance study, where variation was verified in the quality ofthe influent along the height ofthe filters, with increase ofCOD and BOD removal efficency in the eflluent colIected in the lateral exits from O to 80 cm relatively to the false bottom. Whole and halfbamboo rings samples were analyzed, through a mechanical compressioll test, and it was verified stability in the whole bambo o rings degradation after the first year 01 operation ofthe filters, with decrease of28.6% and 31.5% after 1 and 2 years ofuse, respectively / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
225

Avaliação do desempenho de leitos cultivados no tratamento de aguas residuarias de suinocultura

Hussar, Gilberto Jose 29 July 2018 (has links)
Orientador : Denis Miguel Roston / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-07-29T02:49:13Z (GMT). No. of bitstreams: 1 Hussar_GilbertoJose_M.pdf: 2608976 bytes, checksum: efe370a53616f9cd94e1a1faf51c3aea (MD5) Previous issue date: 2001 / Mestrado
226

Biofotonica aplicada ao monitoramento microbiologico de efluentes sanitarios / Spontaneous light emission applied to microbiological wastewater monitoring

Santos, Samuel Ricardo dos, 1980- 02 May 2010 (has links)
Orientadores: Jose Euclides Stipp Paterniani, Cristiano de Mello Gallep / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-15T12:44:58Z (GMT). No. of bitstreams: 1 Santos_SamuelRicardodos_M.pdf: 4212906 bytes, checksum: ecb5c9bc690bf3b7b2b146796b9c61a1 (MD5) Previous issue date: 2010 / Resumo: As bactérias do grupo coliformes têm sido amplamente empregadas no monitoramento da qualidade da água, com o uso da Escherichia coli como microrganismo indicador de contaminação fecal. Os métodos atuais de detecção apresentam no mínimo 18 h para obtenção de resultados e em outros processos, que incluem testes bioquímicos, podem chegar até 48 h para análise conclusiva. A importância de uma rápida detecção de coliformes e Escherichia coli aplicada à qualidade e segurança da água torna-se óbvia e necessária. O uso de medidas da luz, presente em seres vivos, surge como metodologia promissora aplicada ao monitoramento microbiológico das águas, podendo gerar resultados em tempo reduzido de análise. No presente trabalho avaliou-se o potencial da técnica biofotônica aplicada ao monitoramento de efluentes sanitários em seu parâmetro microbiológico, através da detecção de emissão ultrafraca de luz em testes envolvendo coliformes. A metodologia baseou-se no acompanhamento dos padrões de emissão de luz em câmara escura com o uso de efluente doméstico, antes e após tratamento, incubados em meio nutritivo. O controle foi efetuado com o uso de cepa de Escherichia coli (ATCC 25922), incubada em meio nutritivo, tendo seu crescimento monitorado por emissão de luz. Os resultados com cepa e efluente doméstico incubados em substrato cromogênico apresentaram melhores correlações entre crescimento de microrganismos e emissão de luz, em contraste com ensaios efetuados com meio EC e meio nutritivo a base de lactose e lauril triptose. Os dados demonstram que o monitoramento microbiológico pode ser efetuado através da técnica biofotônica, com a identificação da emissão de luz por microrganismos com pelo menos três horas de análise em substrato cromogênico e pelo menos doze horas em meio EC e Presença/Ausência (P/A). / Abstract: The coliform bacteria have been widely used in water quality monitoring, using Escherichia coli as indicator of faecal contamination. Current standard methods for of coliforms and Escherichia coli detection take 18-h minimum and the complete testing process, including confirmatory biochemical tests, may require at least 48 hours. The importance of rapid detection of coliforms and Escherichia coli, regarding to the quality and safety of water, is obvious and necessary. The spontaneous light emission of living systems emerge as a promising methodology that applied to microbiological in monitoring water can lead to shortterm analysis. The present study evaluated the potential of biophoton measurements applied to wastewater monitoring by using ultraweak light emission in coliform tests. The procedure is based on photon-counting measurements inside a dark-chamber, of wastewater samples, before and after treatment, inoculated in nutrient medium. Strain of Escherichia coli (ATCC 25922) was used in control tests by monitoring the light emission in nutrient medium. The results for strain and wastewater incubated in chromogenic substrate show better correlation between microbial growth and light emission, in contrast to experiments with EC Broth and Presence/Absence nutritive medium. The data show that microbiological monitoring can be done by photon-counting with at least three hours in chromogenic substrate and at least twelve hours with EC and Presence/Absence Broth. / Mestrado / Agua e Solo / Mestre em Engenharia Agrícola
227

Desinfecção de aguas utilizando radiação ultravioleta e fotocatalise heterogenea

Donaire, Patricia Pulcini Rosvald 30 November 2001 (has links)
Orientadores : Wilson de Figueiredo Jardim, Jose Roberto Guimarães / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-01T09:39:06Z (GMT). No. of bitstreams: 1 Donaire_PatriciaPulciniRosvald_M.pdf: 4510494 bytes, checksum: 33569310b78db005ff253f9bb485dd16 (MD5) Previous issue date: 2001 / Resumo: Pesquisas de métodos de desinfecção alternativos à cloração vem sendo desenvolvidas e dentre elas destacam-se a radiação ultravioleta e a fotocatálise heterogênea, as quais foram investigadas neste trabalho. Para tal utilizou-se um fotorreator anular comercialmente disponível, que posteriormente foi modificado de maneira que o catalisador pudesse ser introduzido no mesmo por meio de uma camisa de vidro impregnada com o dióxido de titânio ('TI¿¿0 IND. 2¿). O efluente foi bombeado em fluxo ascendente por meio de passagem única e coletado na saída para as análises físico-químicas e bacteriológicas. Foram utilizados como microorganismos indicadores as bactérias Escherichia colí e Clostridium perfringens, provenientes tanto de cepas puras como do ambiente natural. Os parâmetros monitorados nos ensaios fotolíticos e fotocatalíticos foram cor, turbidez, absortividade da água e pH. Nas águas naturais também foram avaliados remoção de coliformes totais e carbono orgânico dissolvido (COD). Os parâmetros de controle de desinfecção UV e UVITi¿0 IND.2¿ foram a dose de radiação UV, carga bacteriana pré e pós-desinfecção e tempo de residência. Os resultados demonstraram que ambos apresentam eficiências de desinfecção bastante significativas em águas contaminadas com altas concentrações de microorganismos. No processo fotolítico, 90 mWs/¿CM POT. 2¿ de dose de UV foram necessários para remover até 4 ordens de magnitude de E.colí, enquanto que no processo fotocatalítico, 120,0 a 140,0 mWs/¿CM POT. 2¿ de dose de UV foram suficientes para alcançar remoções acima de 4 ordens de magnitude para E.coli e coliformes totais. ...Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: Some alternative disinfection methods to chlorination have been developed recently, and among these, the UV irradiation and the heterogeneous photocatalysis have deserved special attention, and were investigated in this work. For this purpose, it was utilized one commercially available annular UV-reactor, used in its original design, as well as modified in terms to accommodate a 'TI¿¿O IND. 2¿ fixed bed in the internal wall of the photoreactor. The up flow reactor worked under single pass. The fecal microorganisms Escherichia coli and Clostridium perfringens, from both pure strain and natural environments, were utilized as pollution indicator microorganisms. The parameters monitored in both photolytic and photocatalytic studies were color, turbidity, water absorbance, pH, removal of total coliform and dissolved organic carbono The control parameters of UV and UV/¿TI¿¿O IND. 2¿ disinfection were UV dose irradiation, initial and final microorganisms counting, and residence time. The results shown that both disinfection process were very efficient in waters with high concentration of microorganisms. In the photolytic process, 90 mWs/¿CM POT. 2¿ UV dose were necessary to remove up to 4 orders of magnitude of E.coli, whereas in the photocatalytic process, doses of 120 up to 140,0 mWs/¿CM POT. 2¿ were enough to remove more than 4 orders of magnitude of E. coli and total coliforms. ...Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
228

Tratamento de residuos da suinocultura : uso de reatores anaerobicos sequenciais seguido de leitos cultivados

Tobias, Antonio Carlos Turcati 01 August 2018 (has links)
Orientador : Denis Miguel Roston / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-01T21:08:49Z (GMT). No. of bitstreams: 1 Tobias_AntonioCarlosTurcati_D.pdf: 1717424 bytes, checksum: aa41e42832aa6770f396051b5a1f67f7 (MD5) Previous issue date: 2002 / Doutorado
229

Aplicação de lodo liquido de esgoto sanitario no solo : determinação de coliformes totais e fecais

Campos, Andreia Ferraz de 28 June 2002 (has links)
Orientador: Bruno Coraucci Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-02T20:26:43Z (GMT). No. of bitstreams: 1 Campos_AndreiaFerrazde_M.pdf: 3482115 bytes, checksum: 2596298effa1ca7f4006d5ec8efe4ef3 (MD5) Previous issue date: 2002 / Resumo: A utilização do Iodo de esgoto na agricultura, como fertilizante, é uma prática conhecida mundialmente devido ao seu potencial de nutrientes, bem como às melhorias proporcionadas na estrutura dos solos transformando este resíduo em um recurso reutilizável. Porém, existem algumas restrições quanto ao seu uso agrícola, entre as quais, a presença de patógenos que além de ser um fator limitante, pode definir a melhor taxa de aplicação do Iodo. Este trabalho teve como objetivo avaliar as concentrações de coliformes totais e, principalmente, coliformes fecais (indicadores de patogenicidade) no Iodo, solo e líquido percolado nas profundidades 25, 50, 75 e 100 cm, por um período de dois anos, em um sistema controlado de disposição de Iodo líquido no solo acondicionado em reatores de fibra de vidro com capacidade para 1200 litros. O Iodo de esgoto foi aplicado em intervalos de, aproximadamente, 40 dias, nas taxas O; 2,5; 5,0 e 7,5 tss/ha (toneladas de sólidos secos por hectare) em solo natural, O e 5,0 tss/ha em solo que sofreu correção de pH por adição de cal. Ao longo do período foi verificado que, mesmo na maior taxa aplicada, os coliformes fecais não estavam presentes no líquido percolado no solo, em até 1 metro de profundidade. Pelos resultados obtidos concluiu-se que a melhor taxa de aplicação foi 5,0 tss/ha em solo natural, devido às concentrações de coliformes fecais na camada superficial do solo (15 cm) ficarem próximas a 106 NMP/g (Número Mais Provável por grama de sólidos secos), concentração limite para biossólidos Classe B. Observou-se ainda que o tempo de sobrevivência dos coliformes fecais no solo superficial nas taxas utilizadas foi maior que 40 dias após as aplicações de Iodo. Portanto, sugere-se que o manejo do solo e as reaplicações de Iodo na taxa 5,0 tss/ha sejam realizados a cada 60 dias, totalizando 30 t/ha.ano / Abstract: The utilization of wastewater sludge in agriculture, as a fertilizer, is a well known worldwide practice, due to its nutrient potential and to the improvements achieved in the soil structure, transforming this waste into a renewable resource. Still, there are some restrictions to its use in agriculture, among which is the presence of pathogens, which, besides being a limiting factor, can define sludge application rates. This study had as its objective the evaluation of the concentration of total coliforms, and especially fecal coliforms (indicators of pathogenity) in the sludge, soil and liquid percolate in 25, 50, 75 and 100 cm depth, during a period of two years, in a controlled 5ystem of soil application of wastewater sludge (fiberglass containers filled with soil). The wastewater sludge was applied at intervals of approximately 40 days, at rates of 0,2.5,5.0 and 7.5 tons per hectare dry basis in natural soil; O and 0.5 tons per hectare in So" with 1íme correction of pH. During the test period was found that even at the highest application rates, fecal coliforms were not present in the liquid percolate in the soil, down to 1 meter depth. Given the obtained results, it was found that the best application rate was 5 tons per hectare in natural soil, since at these rates the concentration of fecal coliforms in the topmost layer of soil (15 cm) remained below 106 MPN/g (Most Probable Number per gram of dry solids), the concentrations limit under Class B biosolids. Furthermore it was observed that the survival time of the fecal coliforms in the top layer of soil were greater than 40 days after soil application, at the different application rates. Therefore it is suggested that soil handling and sludge reapplication in the 5 tons per hectare rate be done every 60 days, totaling 30 tons per year / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
230

Adequação de um lisimetro de sucção para monitoração da agua do solo em saneamento

Pansani, Alexandre 18 January 2001 (has links)
Orientador: Dirceu Brasil Vieira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T03:46:49Z (GMT). No. of bitstreams: 1 Pansani_Alexandre_M.pdf: 6831438 bytes, checksum: e77e6b134ac5b72897a8fc86662d6d22 (MD5) Previous issue date: 2001 / Resumo: A preservação dos recursos hídricos e uma questão de sobrevivência da humanidade, sendo uma das grandes preocupações das lideranças políticas,científicas e acadêmicas.No entanto, é preciso adequar a monitoração destes recursos à realidade brasileira, usando equipamentos de fácil operação e baixo custo, Pode-se citar, por exemplo, os lisimetros de sucção, considerados como viável e compatível Os lisimetros de sucção são constituídos por um tubo de PVC e uma cápsula porosa,sendo que no Brasil são confeccionadas e comercializadas somente cápsulas porosas de cerâmica. Contudo, neste trabalho, foram monitorados lisimetros de sucção desenvolvidos com cápsulas porosas de cerâmica e outros materiais. Os lisimetros de sucção foram instalados em um reservatório com água, e amostras foram coletadas em um intervalo de tempo determinado,sob variações do vácuo aplicado.Posteriormente,os mesmos .foram instalados em um recipiente com solo, com adição de um volume determinado de água coletada no lago da Praça Hermógenes F. Leitão Filho, conhecido como "lago da Unicamp", onde também foram coletadas amostras em um intervalo de tempo determinado, sem variação do vácuo aplicado. Estas amostras ,de águas 'coletadas foram avaliadas -em relação aos aspectos quantitativos: volume coletado e qualitativos: .pH, condutividade elétrica, DQO e fósforo. Os resultados obtidos recomendaram a utilização do lisimetro de sucção confeccionado com cápsula porosa de plástico sintetizado, a instalação dos lisímetros de sucção de maneira invertida no solo e a não utilização do lisímetro de sucção confeccionado com cápsula porosa de cerâmica na determinação da condutividade elétrica e fósforo / Abstract: The preservation of water resource is a question of surViva1 of -humanity,being one ofgreat preocupations os leadership politics, scientifics and academics. Nevertheless,is necessary to adapt the monítoring this resources of a brazílian reality, using equipments of easy operation and cost lous. For example, the lysimeters the succtíon are constitutíve for a PVC pipe and a porous capsule, being that -in Brazil are make and comercialize always porous capsule of ceramics. However, in this work, are to going monitorate lysimeters the sucction developed with porous capsule of ceramícs and others materials. The lysimeters the succtíon are .going to collect in the range time determinate, under variations of vacuum aplicate. Posteriorly, the same are going to Install in the recipient eith soil, with adition " the determinate volume of water collect of "lake 'of {Unicamp", where are going to collect samples in the range time determinate too, without variation of evaluate in relation a quantitatives aspects: volume collect and qualitatives: pH electrical conductivity, COD and phosphorus. The gotten results had recomended the use of the lyslmeters the sucction confectioned With porous sintery plastic capsule, the Installation of the tysimeters the sucction in inverted way in the -ground and not the use of the lysimeters the succtíon confectioned with porous ceramic capsule in the determination of COD and phosphorus / Mestrado / Recursos Hidricos / Mestre em Engenharia Civil

Page generated in 0.6402 seconds