• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 619
  • 7
  • 6
  • 6
  • 6
  • 6
  • 4
  • 2
  • Tagged with
  • 643
  • 643
  • 342
  • 221
  • 167
  • 144
  • 127
  • 107
  • 92
  • 84
  • 80
  • 77
  • 76
  • 67
  • 66
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

Modelagem e simulação de um tratamento de efluentes organicos atraves de redes neurais

Salviano, Francisco Otavio Campelo 19 December 2002 (has links)
Orientador: Ana Maria Frattini Fileti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-03T02:52:04Z (GMT). No. of bitstreams: 1 Salviano_FranciscoOtavioCampelo_M.pdf: 1947577 bytes, checksum: 47d6103eb9ba3a042b3a607b2206d8ae (MD5) Previous issue date: 2002 / Resumo: A motivação inicial do presente trabalho constituiu-se na realização da modelagem do processo de tratamento de efluentes orgânicos da Rhodia Paulínia visando a predição da concentração de nitrogênio no seio do reator biológico e assim fornecendo dados ao operador para controlar a dosagem de hidróxido de amônio, evitando-se o excesso de nitrogênio enviado para a bacia fluvial. Como os fenômenos que ocorrem no reator biológico são de difícil modelagem fenomenológica e, uma vez que existe uma extensa base de dados com todas as informações das variáveis de entrada e saída, a modelagem via redes neurais artificiais foi a escolhida. Através de uma análise qualitativa realizada por especialistas do processo, onze variáveis foram definidas como de entrada e uma variável (concentração de nitrogênio no seio do reator) como saída, formando uma arquitetura da rede neural de 11 neurônios na camada de entrada, 27 na camada oculta e 1 na camada de saída. Utilizando o modelo neural treinado para simular a estação de tratamento de efluentes, detectou-se a realização de um procedimento operacional- adição de anti-espumante ao reator biológico - que trazia sérios problemas de estabilização para a estação, com aumentos bruscos da concentração de nitrogênio. Como conseqüência deste procedimento sem registro, constatou-se que muito dos dados da planilha utilizada para treinamento da rede neural não representavam o processo normal do tratamento de efluentes e por isto os resultados das simulações realizadas discordavam das medições analíticas. Como principal resultado do presente trabalho, relata-se a eliminação da adição de anti-espumante ao reator, permitindo uma melhor estabilização da estação de tratamento. Para que um modelo neural mais adequado seja desenvolvido, novos dados deverão ser coletados e a rede treinada novamente sem a interferência de procedimentos não registrados / Abstract: The present work is concerned on modeling the organic wastewater treatment process at Rhodia Paulinia Plant in order to predict the nitrogen concentration of the biological reactor bulk and also to provide human operators with suitable information to control the ammonium hydroxide dosage, avoiding the excess of nitrogen flowed out to the river. The biological reactor first principIes are very difficult to describe. Besides, a huge process database is available, so that the artificial neural network modeling was choosen. Through the qualitative analysis carried out by experts, 11 variables were defined as input and 1 ( nitrogen concentration of the biological reactor bulk) was defined as output, yielding a neural network architecture with 11 neurons in the input layer, 27 neurons in the hidden layer and 1 in the output layer. By using the trained neural model to simulate the wastewater treatment, it was detected the occurence of an unsuitable non-reported operational procedure - anti-foaming addition to the biological reactor. Serious stabilization problems occured, with abrupt nitrogen concentration increasing. As a consequence of this non-reported procedure, the simulation results did not match to the analytical measurements. The main result ofthe present work is the interruption of the anti-foaming addition and the wastewater treatment stabilization. In order to develop a suitable neural model, new process data must be collected and the neural network must be retrained without any interference of non-reported procedures / Mestrado / Sistemas de Processos Quimicos e Informatica / Mestre em Engenharia Química
232

Inertização de lodo de esgoto em tijolos ceramicos maciços : aspectos tecnologicos e ambientais

Nuvolari, Ariovaldo 22 August 2002 (has links)
Orientador: Bruno Coraucci Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T09:44:32Z (GMT). No. of bitstreams: 1 Nuvolari_Ariovaldo_D.pdf: 13564334 bytes, checksum: 541c5d53234a1512560fc168a9f9a408 (MD5) Previous issue date: 2002 / Resumo: O lodo de esgoto sanitário é gerado nas estações de tratamento de esgoto (ETEs), em quantidades significativas. O seu destino final é um dos mais sérios problemas ambientais, em nível mundial, podendo-se optar por duas linhas gerais de decisão, quais sejam, o descarte controlado ou a utilização. Em termos de descarte, a tendência é a disposição em aterros sanitários. A utilização mais nobre é na melhoria de solos agrícolas, desde que respeitadas as condicionantes ambientais, tipos de solos, culturas, etc. Quando isto não é possível, outras alternativas têm sido estudadas, dentre elas, a inertização em tijolos cerâmicos, objeto desta pesquisa. Nesta, foram utilizados, como matéria prima, um solo argiloso, dois diferentes tipos de lodo (LDl e LD2) e suas cinzas. O LDl, oriundo de um sistema convencional de lodos ativados, foi condicionado com cal e c1oreto férrico e desaguado em filtro-prensa de placas. O LD2, oriundo de um reator anaeróbio de fluxo ascendente foi desaguado em leito de secagem, sem condicionamento químico. Os lodos foram coletados na ETE Jesus Neto, Bairro do Ipiranga em São Paulo e em seguida; destorroados, secos em estufa a 105°C, passados em peneira n° 10 - ASTM (2,0 mm de abertura) e armazenados. Os lodos foram misturados ao solo argiloso (previamente seco ao ar e passado na peneira de 2,0 mm), nas proporções de 10, 20 e 30 % (em peso seco). Parte dos lodos armazenados foram colocados em forno-mufla a 900°C e transformados em cinzas. Estas foram misturadas ao solo nas proporções de 10,20,30 e 40 %. Uma massa cerâmica feita apenas com o solo foi utilizada como testemunho. Os tijolos foram moldados manualmente, secos ao ar por no mínimo 10 dias, em estufa a 105°C por 24 horas e queimados a 950°C. Foram avaliados os parâmetros e condicionantes tecnológicos e ambientais para o emprego dos mesmos na construção civil, tendo-se conc1uido que tanto o LD 1 quanto o LD2, quando utilizados após secagem a 105°C, só podem ser utilizados com até 10 % de lodo na massa cerâmica. As cinzas do LD 1 podem ser utilizadas com até 40 % na mistura com o solo argiloso. No entanto, o uso das cinzas do LD2 foi considerado desaconselhável por causa do nível de radioatividade presente neste resíduo / Abstract: Significant quantities of sewage sludge is produced in the wastewater treatment plants (WTPs). At global level, its final destination is one of the most serious environmental issues, allowing two options to be chosen: the controlled discard or its utilization. In terms of the discard there is a general trend of landfilling utilization. The most noble utilization of the sewage sludge is in the improvement of agricultural soils, since that verified the environmental conditions, soil tipology, crops, eg. When this is not possible, however, other options can be chosen, such as ceramics bricks utilization, which is the subject of the present research. Here, the studies carried out with one clay-soil and two different kinds of sewage sludge (called LD1 and LD2) and their dusts are presented. The LD1 is from a conventiona1 system of activated sludge, dehydrated in plate's press filter, after amended with CaO and FeCl3. The LD2 is from a up flow anaerobic shaped bed reactor (UASB), dehidrated in drier bed and without the inclusion of any chemical substance. After the collection of the two sewage sludges (LD1 and LD2), from the Jesus Neto WTP, Bairro Ipiranga in São Paulo city, the samples were grinded, dryed at 105 °C, sieved with number 10-ASTM sieve (2,0 mm) and stored. They were mixed with clay-soil (previously dried in open-air, grinded and sieved with number 10-ASTM), using 10, 20 and 30 % proportions (dried weight). Part of the sewage sludge was burned at 900°C and became ash, which was also mixed with soil at 10, 20, 30 and 40 % proportions. Another sample, made only with soil, was used as control. The bricks were shaped by hand, dried in open-air for a minimum of 10 days, dried in stove at 105 °C for 24 hours and burned at 950 oC. The technological and environmental parameters for their use in civil construction were evaluated. LD 1 and LD2 can be used in up to 10 % proportions. LD 1 ashes can be used in up to 40 % proportions. On the other hand, for the LD2 ashes, is not advisab1e the use of this material in ceramic bricks, because the results concerning its radioactive content / Doutorado / Saneamento / Doutor em Engenharia Civil
233

Preservação de efluentes para analise de carbono organico dissolvido

Galrão, Divanildes da Silva 03 August 2018 (has links)
Orientadores: Jose Roberto Guimarães / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T19:05:03Z (GMT). No. of bitstreams: 1 Galrao_DivanildesdaSilva_M.pdf: 1700452 bytes, checksum: 00008e31bdce85af5b908dfa92cf19fd (MD5) Previous issue date: 2003 / Mestrado
234

Avaliação fisico-quimica e microbiologica da agua subterranea em area irrigada com efluente de filtro anaerobio

Vendemiatti, Josiane Aparecida de Souza 09 January 2003 (has links)
Orientadores: Antonio Roberto Siviero, Edson Aparecido Abdul Nour / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T22:20:00Z (GMT). No. of bitstreams: 1 Vendemiatti_JosianeAparecidadeSouza_M.pdf: 5863088 bytes, checksum: 45d31c4a8712ae8ec58cd6024ad71779 (MD5) Previous issue date: 2003 / Resumo: Avaliação físico-química e microbiológica da água subterrânea em área irrigada com efluente de filtro anaeróbio. Campinas, Faculdade de Engenharia Civil, Universidade Estadual de Campinas, 2003. 134pág. Dissertação de Mestrado. Os objetivos principais da aplicação de efluentes no solo são o pós-tratamento, a redução no uso de fertilizantes e suprimento de água em regiões de escassez. O manejo adequado deste sistema é fundamental para a proteção da qualidade da água subterrânea que em diversos locais, é utilizada como principal fonte de abastecimento, devido à deterioração da qualidade das águas superficiais. A presente pesquisa foi desenvolvida no município de Limeira/SP, e teve como objetivo principal monitorar a alteração da qualidade da água subterrânea de uma área agrícola utilizada como póstratamento de efluente de um reator anaeróbio. A área experimental foi dividida em blocos, com plantações de milho, e subdividida em parcelas irrigadas com água e efluente anaeróbio proveniente de filtros anaeróbios de fluxo ascendente com enchimento de bambu. O método de irrigação empregado foi de superfície, técnica de sulcos rasos. As lâminas hídricas aplicadas foram de 20, 40 e 60 cm, obedecendo a capacidade de campo do solo e a necessidade hídrica da planta. Na área experimental foram construídos onze poços de monitoração, distribuídos entre as parcelas de milho irrigadas com efluente e água. A disposição dos poços obedeceu ao sentido do fluxo da água subterrânea e a ordem crescente das lâminas hídricas. A qualidade da água subterrânea foi monitorada por meio de análises físico-químicas e bacteriológicas dos seguintes parâmetros: pH, cor, turbidez, sólidos totais dissolvidos, condutividade elétrica, salinidade, cloreto, nitrato, nitrito, quantificação de coliformes totais, Escherichia coli, Estreptococos fecais (Enterococcus) e bactérias heterotróficas. Em geral, a aplicação do efluente anaeróbio não influenciou de forma negativa na qualidade da água subterrânea monitorada. A precipitação pluviométrica pode acentuar os efeitos da contaminação por alguns elementos quando associada à aplicação do efluente no solo. Foi observado que mesmo no período de seca houve diferença significativa, para alguns parâmetros, entre as irrigações com água e efluente. O mesmo ocorreu na comparação entre o Poço controle e os poços das parcelas irrigadas com água e efluente para o mesmo período. Deve-se considerar que a irrigação por efluentes tem um grande potencial quanto ao fornecimento de nutrientes para o solo e planta além de suprir a necessidade de água para a agricultura. Contudo, são necessários o manejo adequado e a monitoração constante do sistema para minimizar os efeitos de contaminação no solo e no aqüífero / Abstract: Groundwater physicochemical and microbiological evolution in irrigated area with anaerobic filter. Campinas, Civil Engineering College, Campinas State University, 2003. 1130pag. Master Dissertation. The main aim of effluent application on soil is to reduce, or eliminate the use of fertilizers and supply the water necessity. Proper leandling in the system is fundamental for groundwater protection quality. Several places is used as main supply resource due to quality deterioration of superficial waters. This research took place in the municipal area of Limeira S.P. Its main goal was to monitor groundwater quality alteration in an agricultural area used as effluent post treatment of an anaerobic reactor. The experimental area was divided into blocks with maize crops and subdivided into parts irrigated with water and anaerobic effluent. The irrigation method was employed by ascending flow filled with bambu surface, shallow furrow technique. Considering soil field capacity plus plant hydric necessity, were applied 20, 40 and 60 cm. Eleven monitor wells were built in the area. It was distributed among the maize parts irrigated by water plus effluent. The disposition these monitor followed the groundwater flow direction and hydric blade crescent order. Groundwater quality was controlled by physicochemical and bacteriological analyses such as pH, color, turbidity, solved total solids, electrical conductivity, salinity, chloride, nitrate, nitrite, total coliform quantification, escherichia coli, faecal streptococcus, (Enterococcus) and heterotrophic bacterias. Anaerobic effluent did not influence the supervised groundwater quality. But, pluviometric precipitation was able to emphasize the effects of contamination for some elements the use of effluent on soil. It was observed that on the dry period there was significant difference, for some parameters, regarding the irrigation with water and effluent. The similar occurred the control well and the well for the irrigated parts with water and effluent on the same period. It should be considered that, effluent irrigation has a good potential as nutrient supply for soil and plant. Besides providing necessary water for agriculture. However, it was necessary and proper handling, plus system constant supervision for to minimize and contamination effects on soil and aquifer / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
235

Otimização de uma unidade de Air Stripping para remover BTEX de aguas residuarias

Silva, Consuelo Cristina Gomes 13 August 2004 (has links)
Orientador: Reginaldo Guirardello / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-03T22:33:18Z (GMT). No. of bitstreams: 1 Silva_ConsueloCristinaGomes_M.pdf: 1700273 bytes, checksum: 223e8e7c5d3ede67496010e0d1185395 (MD5) Previous issue date: 2004 / Resumo: Com a busca constante pelo Desenvolvimento Sustentável, os órgãos ambientais estão demandando uma maior atenção à contaminação de recursos hídricos, provenientes de águas residuárias. As águas residuárias podem ser provenientes de descartes domésticos, industriais ou ainda pluviais. Os compostos químicos causam danos à saúde e ao equilíbrio dos ecossistemas. Um caso particular e de interesse é o caso do BTEX (Benzeno, Tolueno, Etilbenzeno e os Xilenos), pois, estes compostos são solventes de uso industrial comum e são tóxicos à saúde humana, além de inviabilizarem a exploração de aqüíferos por eles contaminados. Nesta pesquisa, apresentamos uma configuração otimizada em termos de consumo energético e custo fixo para uma unidade de Air Stripping respeitando as restrições ambientais e operacionais, descrevendo e efetuando o projeto ótimo da unidade para a remoção de BTEX presente em águas residuárias, apresentando uma metodologia para elaboração de projetos de sistemas de tratamento, dimensionando bombas e sopradores, elaborando um projeto de colunas de pratos perfurados e estimando custos em plantas químicas. O modelo considerado nesta pesquisa foi desenvolvido por ALBUQUERQUE (2002). Para a simulação da unidade de Air Stripping, usamos o pacote computacional GAMS (General Algebric Modeling System), que é designado à construção e solução de modelos grandes e complexos de programação matemática. Para a otimização da unidade, trabalhamos com Programação Não Linear e Programação Mista Inteira Não - Linear, a fim de minimizar o impacto resultante do lançamento destes poluentes e sua dispersão no meio ambiente. Os resultados indicam a remoção dos contaminantes em grau satisfatório para a unidade, além de atingirem os objetivos propostos / Abstract: With the constant search for the Sustainable Development, the ambient agencies are demanding bigger attention to contamination of resources hídricos, proceeding from residuary waters. The residuary waters can be proceeding from domestic, industrial or still pluvial discardings. Chemicals cause damages to the health and to the balance of ecosystems. A particular case of interest is the case of BTEX (Benzene, Toluene, Etilbenzene and the Xilenes), which are solvents of common industrial use and are toxic to the health human being, besides making impracticable the exploration of water-bearing or contaminated by them. In this research we present an optimal configuration in terms of energy consumption and fixed cost for a unit of Air Stripping, describing and effecting the excellent project of the unit for the present removal of BTEX in residuary waters, presenting a methodology for elaboration of projects of treatment systems, design bombs and puffers, elaborating a project of perforateed plate columns and estimating costs in chemical plants.The model considered in this research was developed by ALBUQUERQUE (2002). For the simulation of the unit of Air Stripping we use computational package GAMS (General Algebric Modeling System) that it is assigned to the construction and solution a complex models of mathematical programming. For the optimization of the unit we work with Non Linear Programming and Integer Mixed Non Linear Programming, in order to minimize the resultant impact of the launching of these pollutants and its dispersion in the environment. The results indicate remova I of the contaminates in satisfactory degree for the unit, besides reaching the objectives proposed in this work / Mestrado / Desenvolvimento de Processos Químicos / Mestre em Engenharia Química
236

Tratamento de efluente bruto citrico liquido no solo por meio de sulcos largos de infiltração

Carraro, Venilton Jose 03 November 1999 (has links)
Orientador: Roberto Feijo de Figueiredo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-24T20:47:03Z (GMT). No. of bitstreams: 1 Carraro_VeniltonJose_M.pdf: 4145062 bytes, checksum: 12ff27fe25f25f667f0b7641516fdcee (MD5) Previous issue date: 1995 / Resumo: Aplicou-se o processo de tratamento de efluente bruto de no solo através de sulcos largos de infiltração, irrigando Eucalyptus grandis. Foi utilizada para isso uma área de 2 ha onde foi analisado o método de tratamento no solo e foram monitoradas água retirada de sondas de ponta porosa, coletores de drenagem livre e poços de observação, comparando os resultados com uma área não irrigada. Foram feitas análises do solo da área nas profundidades de Oa 25, de 25 a 50, de 50 a 75 e de 75 a 100 cm., com a finalidade de se detectar alguma influência do resíduo líquido nas características químicas do solo, comparando-o com uma área não irrigada. Foi acompanhado o desenvolvimento radicular, perímetro do caule e altura das plantas da área experimental e de uma área testemunha, que não recebeu irrigação. Esse monitoramento teve a finalidade de detectar influências desse processo no desenvolvimento dos eucaliptos após comparação entre as áreas. Os resultados obtidos indicam uma boa eficiência na remoção de matéria orgânica, turbidez, cor e sólidos suspensos. As porcentagens de remoção de D Q O ultrapassaram 90 porcento. Não ocorreu nenhum efeito negativo sobre o crescimento das plantas durante o experimento / Abstract: Raw effluent &om a citrus processing plant was applied on soil across wide furrows infiltration method, with Eucalyptus grandis as crop. A total area of 2 hectares was utilized for that purpose where water samples were collected &om lysimeters, &ee-drainage collectors, and observations wells. Results &om irrigated and non-irrigated area were compared. Soil samples &om different depths ( Oto 25, 25 to 50, 50 to 75, and 75 to 100 cm) were analyzed, aiming the detection any possible effects of the effluent upon soil chemistry characteristics, both for irrigated and non-irrigated areas. AIso root development, perimeter, and height of the plants &om irrigated and non-irrigated areas were monitored. Results indicated a good efficiency on organic matter, turbidity, color and suspended solids remova!. Removal of COD was above 90 percent. No deleterious effect was notices on the vegetation / Mestrado / Recursos Hidricos e Saneamento / Mestre em Engenharia Civil
237

Avaliação da remoção de sulfeto de hidrogênio de biogás provindo da digestão de efluente suinícola utilizando biofiltro em escala piloto

Pirolli, Mateus January 2016 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Química, Florianópolis, 2016. / Made available in DSpace on 2016-09-16T14:01:20Z (GMT). No. of bitstreams: 1 342009.pdf: 1220880 bytes, checksum: 210f5e879e54994a097169c2307e0952 (MD5) Previous issue date: 2016 / O tratamento anaeróbio de efluentes da suinocultura, águas residuárias ricas na presença de sulfato, podem gerar sulfeto de hidrogênio (H2S). A utilização típica do biogás gerado rico em energia requer antecedente remoção de compostos de enxofre para processos de recuperação de energia para evitar problemas de corrosão em motores de combustão, bem como para a saúde humana e a proteção do ambiente. Desse modo, a aplicação em escala piloto de um biofiltro do tipo biotrickling (BTF), simples e de baixa manutenção, em escala piloto, para dessulfurização de biogás derivado do tratamento anaeróbio de água residuária de suinocultura e com a capacidade de aumento nas concentrações de biometano, foi investigada. Como meio de cultura dos microrganismos, o BTF foi continuamente alimentado com efluente de águas residuais provenientes de um biorreator de lodos ativados (nitrificação-desnitrificação) instalado a jusante de um biodigestor anaeróbio tipo UASB. A eficiência máxima de remoção do BTF foi de 99,8% obtida com uma capacidade de eliminação máxima (CE) de 4,80 g H2S m-3 h-1. Médias de CE obtidas com as vazões de entrada do fluxo de biogás de 0,024, 0,036 e 0,048 m-3 h-1 foram de 2,26; 3,26 e 1,35 g H2S m-3 h-1, respectivamente. As formas SO4-2 e S0 foram os principais metabólitos produzidos a partir da conversão biológica de H2S. Adicionalmente à capacidade biodessulfurização satisfatória, um aumento médio da concentração de metano de ? 3,8 ± 1,68 g m-3 foi medida no fluxo de gás filtrado ao longo de 200 dias de operação do BTF. Análises TR-PCR das comunidades archaeas no biofilme confirmaram dominância de archaeas metanogênicas hidrogenotróficas, corroborando com forte correlação observada entre a remoção de CO2 e produção de CH4. Entre as três principais ordens archaeas investigadas (Metanosarcinales, Metanobacteriales e Metanomicrobiales), Metanobacteriales foram encontradas em concentrações mais elevadas (1,9 × 1011 cópias de genes mL-1). O BTF proposto foi robusto, removendo eficientemente H2S do biogás concomitantemente, aumentando a concentração de biometano como fonte valiosa de combustível renovável.<br> / Abstract : Anaerobic treatment of concentrated swine wastewater, which is sulfate-rich wastewater, can generate hydrogen sulfide (H2S). Usage of the generated energy-rich gas requires the removal of sulfur compounds before energy recovery processes for avoiding problems of corrosion in combustion engines as well as for human health and environmental protection. The application of a simple and low maintenance field-scale biotrickling filter (BTF) for desulfurization of swine wastewater-derived biogas stream that was also capable of increasing biomethane concentrations was investigated. As the culture medium of the microorganisms, the BTF was continuously fed with wastewater from an air sparged nitrification-denitrification bioreactor, installed down gradient from an UASB-type digester. BTF maximum removal efficiency of 99.8% was achieved with a maximum elimination capacity (EC) of 4.80 g H2S m-3 h-1. Average EC obtained with inlet biogas flow rates of 0.024, 0.036 and 0.048 m3 h-1 was 2.26; 3.26 and 1.35 g H2S m-3 h-1, respectively. SO4-2 and S0 were the major metabolites produced from biological conversion of H2S. Additionally to the satisfactory biodesulfurization capacity, an average increase in methane concentration of ? 3.8 ±1.68 g m-3 was measured in the filtered gas stream throughout 200 days of BTF operation. RT-PCR analyses of archaea communities in the biofilm confirmed dominance of hydrogenotrophic methanogens thus corroborating with observed strong correlation between CO2 removal and CH4 production. Among the three major archaeas orders investigated (i.e., Methanosarcinales, Methanobacteriales, and Methanomicrobiales), Methanobacteriales were encountered at highest concentrations (1.9×1011 gene copies mL-1). The proposed BTF was robust efficiently removing H2S from biogas stream while concomitantly enhancing the concentration of valuable methane as source of renewable fuel.
238

Tratamento do efluente da industria de queijos por processos biologicos e quimicos / Treatments of whey effluent by biological and chemical processes

Almeida, Edna dos Santos 20 December 2004 (has links)
Orientador : Nelson E. Duran Caballero / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-04T02:17:41Z (GMT). No. of bitstreams: 1 Almeida_EdnadosSantos_D.pdf: 3114462 bytes, checksum: 725a81db3141bc2ac22029bf644ea866 (MD5) Previous issue date: 2004 / Doutorado / Físico-Química / Doutor em Quimica
239

Pos-tratamento de efluentes de filtro anaerobio utilizando o metodo de escoamento superficial no solo : avaliação de taxas de aplicação

Klusener Filho, Luiz Carlos 01 February 2003 (has links)
Orientador: Roberto Feijo de Figueiredo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T15:43:28Z (GMT). No. of bitstreams: 1 KlusenerFilho_LuizCarlos_M.pdf: 3565006 bytes, checksum: f8838ac954e146367d5f6da7c0f79277 (MD5) Previous issue date: 2003 / Resumo: No Brasil, a maior parte dos esgotos sanitários gerados não é tratada, constituindo um dos principais problemas de saúde pública. Um dos grandes desafios é tentar melhorar essa situação através de sistemas de tratamento que sejam razoavelmente eficientes e que apresentem baixo custo, características nas quais se enquadra o sistema de filtros anaeróbios. Entretanto, este carece de pesquisas para atingir um grau maior de eficiência. O presente trabalho visa melhorar essa eficiência agregando aos filtros anaeróbios um sistema de disposição controlada de efluente no solo, o método de escoamento superficial ("overland flow"). Obteve-se com este trabalho não apenas a melhoria da qualidade do efluente final do sistema, mas também a avaliação de parâmetros do sistema e das taxas hidráulicas de aplicação durante o seu funcionamento / Abstract: In Brazil, most of the generated sanitary sewers is not treated, constituting one of the main problems of public health. One of the great challenges is to try to improve this situation through treatment systems that are razoavelmente efficient and that they present low cost, characteristics in which if it fits the system of anaerobic filters. However, this lacks of research to reach a bigger degree of efficiency. The present work aims at to improve this efficiency adding to the anaerobic filters a system of controlled disposal of effluent in the ground, the method of superficial draining (overland flow). The improvement of the quality of the effluent end of the system expects not only with this work, but also the determination of preliminary parameters of sizing, and the hydraulical tax of excellent application for its functioning / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
240

Ultrafiltracão e electrocoagulação de filtrados do branqueamento de uma fábrica de polpa celulósica kraft para fins de reuso / Ultrafiltration and electrocoagulation of bleaching filtrates from a kraft pulp mill for reuse porpuses

Quezada Reyes, Rafael Ignacio 27 July 2017 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2018-10-30T15:16:27Z No. of bitstreams: 1 texto completo.pdf: 1364132 bytes, checksum: 0ce39e5397bb83fb85f634ab2330eebb (MD5) / Made available in DSpace on 2018-10-30T15:16:27Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1364132 bytes, checksum: 0ce39e5397bb83fb85f634ab2330eebb (MD5) Previous issue date: 2017-07-27 / Devido ao contínuo aumento das restrições ambientais em fábricas produtoras de polpa celulósica, a indústria tem procurado encontrar opções para minimizar o consumo de água, aumentar o reúso da água e melhorar a qualidade do efluente final. O tratamento de correntes líquidas setoriais da fábrica pode ser uma alternativa técnica e economicamente atrativa por possuírem baixos volumes e altas concentrações quando comparados ao efluente final que consiste na mistura de todos os efluentes da fábrica. Em estudos anteriores, foi determinada a viabilidade de utilizar ultrafiltração para o tratamento do efluente alcalino do setor de branqueamento da fábrica. O primeiro objetivo desse estudo foi avaliar o reúso do permeado gerado e a disposição do concentrado no ciclo de recuperação química. Os resultados indicaram que é possível substituir 100% da água quente na prensa (EPO) sem gerar incrustações de carbonato de cálcio e hidróxido de magnésio. De acordo com a caraterização do concentrado, estima-se que é possível a disposição do concentrado na área de evaporadores sem aumentar o risco de formação de incrustações ou afetar o funcionamento da caldeira de recuperação. O segundo objetivo foi determinar a viabilidade técnica de tratar o efluente ácido do setor de branqueamento com membranas de ultrafiltração e avaliar mediante simulações por software a viabilidade de reusar o permeado, a formação de incrustações de sulfato de bário e os efeitos na estação de tratamento de efluentes da fábrica. Os resultados indicaram que é possível tratar o filtrado ácido com membranas de ultrafiltração, a remoção de matéria organica e cor foi de 65% e 82% respetivamente. A simulação por software indicou que a de substituição de 25% da água branca na prensa do primeiro estagio D pelo permeado, aumenta em 10% o risco de formação de incrustações de sulfato de bário. Neste caso o efluente final da fábrica possuiria uma carga de DQO 38% menor e a geração de lodo biológico diminuiria em 40%. O terceiro objetivo foi avaliar o tratamento de eletrocoagulação com eletrodos de ferro e alumínio, dos efluentes ácido e alcalino, determinar a viabilidade técnica de reusar os efluentes tratados e determinar os efeitos na estação de tratamento de efluentes (ETE). Os resultados indicaram que tanto para o efluente ácido como para o efluente alcalino, a maior remoção de DQO foi obtida com o tratamento de eletrocoagulação com eletrodos de alumínio, 51% e 48% respectivamente. Pelas características finais dos efluentes tratados, conclui-se que os mesmos podem substituir a água quente na prensa (EPO) sem aumentar o risco de formação de incrustações de carbonato de cálcio. A substituição da água quente pelo efluente tratado diminui o consumo de água em 7,5 m 3 por tonelada de polpa seca. / Due to the continuous rise of environmental concern of the pulp industry, it is necessary to find options that minimize the water consumption, and enhance effluent quality. The treatment of specific in-plant stream seems to be an attractive technical and economical approach because of the smaller amount of effluent to be treated compared with the total final effluent volume. Previous studies have shown that it is possible to treat alkaline extraction (EPO) effluent with ultrafiltration membranes. The first objective of this study was to evaluate the reuse of the ultrafiltration (UF) permeate and the transfer of the retentate to the chemical recovery cycle. The results showed that it was possible to replace 100% of the hot water in the (EPO)-press without generating scaling of calcium carbonate or magnesium hydroxide. According to the characteristics of the retentate, it is assumed that it is possible to transfer the UF-retentate to the evaporator area without increasing the risk of fouling or negatively affecting the operation of the recovery boiler. The second objective was to evaluate the feasibility of the bleaching plant acidic effluent ultrafiltration membrane treatment and study, using software simulations, the feasibility of reusing the permeate determining the risk of barium sulfate scaling and the effects on the final effluent treatment plant. The results indicated that it was possible to treat the acidic effluent with UF membranes, the removal of COD and color was 65% and 82%, respectively. Software simulation indicated that the 25% replacement of white water in the first D-stage press would increase by 10% the risk of barium sulfate formation. The final total effluent of the mill decreased by 38% of the COD load and the biological sludge generation decreased by 40%. The third objective was evaluating the electrocoagulation treatment with iron and aluminum electrodes of acidic and alkaline bleaching plant effluents, to determine the technical feasibility of reusing the treated effluents and to determine the effects on the effluent treatment plant. The results indicated that for both, acidic and alkaline effluent, the highest COD removal was achieved with the electrocoagulation treatment with aluminium electrodes, 51% and 48%, respectively. Due to the pH and composition of the treated effluents, both treated effluents could replace hot water in the (EPO) press without increasing the risk of calcium carbonate scale formation. The substitution of hot water by treated effluent reduced water consumption by 7.5 m 3 / ADt.

Page generated in 0.7558 seconds