• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo cinético do Processo de Valo Cynamon-Roque: caracterização e obtenção de parâmetros de projeto / Cynamon-Roque ditch process kinetics study: characterization and design criteria establisment

Silva, Dalton Marcondes January 2000 (has links)
Made available in DSpace on 2016-02-26T13:26:11Z (GMT). No. of bitstreams: 2 162.pdf: 5694761 bytes, checksum: 9c22514a37e7fa915b7fe998fc46e8a9 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2000 / O processo de valo Cynamon-Roque, de tratamento de esgotos, constituído de um reator anaeróbio e outro aeróbio, vem sendo testado desde 1986, através de uma unidade piloto, construída no Campus da FIOCRUZ, que recebe uma mistura de esgotos domésticos e industriais, oriundos de unidades de ensino, pesquisa, manutenção e fábricas de vacinas. A validade do processo foi amplamente demonstrada, o que resultou na patente obtida em 1996. As características funcionais vantajosas do processo, em relação aos tradicionais são: requer pouca área, sua operação é simples, a remoção de matéria orgânica é elevada, fruto de uma operação semelhante à do processo dos lodos ativados, permite considerável remoção de nutrientes, não libera aerossóis no meio ambiente, pois a unidade aeróbia é fechada, apresenta boa remoção de patogênicos e economia energética. Neste trabalho, avaliamos as características operacionais do valo Cynamon-Roque, quando sujeito a vazões superiores às do projeto original. Devido às grandes variações horárias de vazão, concentração, do afluente da unidade piloto, e a perda de sólidos, foi empregado um modelo cinético transiente, de pouca complexidade, mas adequado para modelagem matemática do processo de degradação. As perdas de sólidos foram ocasionadas em virtude dos decantadores terem sido dimensionados para vazões muito inferiores às utilizadas. Através deste modelo, testamos a validade de duas equações cinéticas, a de Monod e a de Eckenfelder, para degradação de substrato, obtendo-se ajustes semelhantes. Uma metodologia para obtenção de parâmetros para um projeto racional é apresentada e discutida ao longo deste trabalho. O comportamento do processo, noutras condições operacionais, foi previsto, utilizando-se o modelo cinético, com os parâmetros determinados através do ajuste deste, aos dados experimentais. / Foi realizado um levantamento preliminar sobre a estabilidade do reator anaeróbio, o consumo de oxigênio do reator aeróbio e o desempenho dos decantadores. A comparação do consumo de energia do valo Cynamon-Roque com dois processos tradicionais, o valo clássico e o lodo ativado, demonstrou a grande potencialidade do processo em estudo. / Cynamon-Roque ditch process, a sewage treatment process, given by an anaerobic reactor followed by an aerobic reactor, has been tested since 1986, throw a pilot plant, build in FIOCRUZ Campus, which receive domestic and industrial sewage from teaching, research, repairing units and vaccines industries. The process validity has been quite demonstrated, so it was patented in 1996. The advantageous functional features of the process, taking into account the traditional process are: it needs small areas, its operation is simple, organic matter removal is high, because it works in a similar way to the activated sludge process, nutrients removal is remarkable, it does not release aerosols in the environment, because the aerobic unit is closed, exhibits good removal of pathogenic organism and saves energy.In this work, Cynamon-Roque ditch operational features has been evaluated, when subject to flows bigger than the original project ones. Due to the great hour variations of flow, concentration, of the influent from the pilot plant, and the loss of solids, it was used a transient kinetic model, of little complexity, but appropriate for the bio-degradation process mathematical modeling. The loss of solids was caused by the fact that the settling tanks were designed to operate at much lower flows than those used. Taking into account the model, the validity of two kinetic equations was tested - Monod and Eckenfelder - for the bio-degradation of substrate, and similar fit resulted.A methodology for determining the coefficients necessary for establishing rational design criteria is presented and discussed throughout this work.The process behavior, under other operational conditions, was previewed, through the kinetic model, which coefficients were determined by adjusting it to the experimental data. / A preliminary evaluation was realized about the stability of the anaerobic reactor, the consumption of oxygen in the aerobic reactor and the settling tanks performance. The energy consumption comparison between Cynamon-Roque ditch and two traditional processes - classical ditch and activated sludge - showed the great potential of the process being studied. (AU)^ien
2

Procedimentos de análise por injeção sequencial para determinação espectrofotométrica de sulfeto em amostras ambientais explorando a formação do azul de metileno / Sequential injection analysis procedure for spectrophotometric determination of sulfide in environmental samples by exploring the formation of methylene blue

Silva, Marcelo Solitrenick Pinto 13 March 2003 (has links)
Esta tese demonstra a aplicação da análise por injeção seqüencial (SIA) para determinação de sulfeto utilizando a química da formação do azul de metileno, a qual se baseia em dois reagentes: solução de cloridrato de dimetil p-fenileno diamina (DMPD) 3,63 mmol L-1 em meio de HCI 1,1 mol L-1 e solução de cloreto de ferro (III) 19 mmol L-1, também em meio de HCI 1, 1 mol L-1. Estas soluções foram aspiradas para dentro de uma bobina coletora do sistema SIA como duas zonas de reagente, entre as quais aspirava-se a solução da amostra. Em condições otimizadas o limite de detecção foi calculado em 40 µg L-1 de S2-, com uma faixa dinâmica de resposta linear entre 0,05 e 2,0 mg L-1 . Esta faixa linear pode ser ampliada até 32 mg L-1 utilizando-se uma etapa de diluição in-line para concentrações maiores do que 2,0 mg L-1 de S2- . As características de robustez do sistema SIA que utiliza uma bomba de pistão, confere alta estabilidade para as curvas analíticas (precisão de 4%), minimizando a trabalhosa preparação de padrões de S2-. O método foi aplicado na determinação de sulfeto volatilizável por ácidos (AVS) em sedimentos coletados em reservatórios da região metropolitana de São Paulo (RMSP) e no reservatório de Barra Bonita no rio Tietê, localizado 270 km a jusante em relação à cidade de São Paulo. As concentrações de AVS foram 9 a 14 mg kg-1 nos sedimentos de Barra Bonita e entre 1,2 e 14 g kg-1 nos sedimentos dos reservatórios Billings, Pirapora e Rasgão. Esta tese também descreve o acoplamento da análise por injeção seqüencial com análise por fluxo monossegmentado (SI-MSFA) para determinação de sulfeto em níveis de concentração típicos de águas residuais. As curvas analíticas foram construídas por diluição in-line de uma única solução padrão. A robustez do método proposto foi verificada construindo-se curvas analíticas em diferentes dias de trabalho e comparando-se os coeficientes angulares, os quais apresentaram um desvio padrão relativo de 5,2% (n=5) para uma faixa de concentração entre 0,17 e 1,0 mg L-1 de S2-. A freqüência de amostragem foi de 38 análises por hora, com um limite de detecção de 40 µg L-1. A adequabilidade do método SI-MSFA para realizar adições de padrão para determinação de S2- também foi descrita. Amostras simuladas foram analisadas pelo método proposto, apresentando taxas de recuperação entre 70 e 115%, demonstrando a adequabilidade do método SI-MSFA para realizar análise in-situ de S2- em estações automáticas de monitoramento. / This thesis demonstrates the application of sequential injection analysis (SIA) to perform sulfide determination using the methylene blue chemistry, based on two reagents: 3.63 mmol L-1 N,N dimethyl-p-phenylene diamine hydrochloride in 1.1 mol L-1 HCI solution and 19 mmol L-1 FeCl3, also in 1.1 mol L-1 HCI. These solutions are aspirated inside the holding coil of the sequential injection system as two reagent zones sandwiching the sample zone. Under optimized conditions, the detection limit was calculated at 40 µg L-1 S2-, with a linear dynamic range from 0.05 to 2 mg L-1 S2-. This linear range can be extended up to 32 mg L-1 using in-line dilution for sulfide concentrations greater than 2 mg L-1. The robust characteristic of the SI system with syringe pump leads to very stable analytical curves (precision of 4%), minimizing the laborious preparation of sulfide standards. The method was applied in the determination of acid volatile sulfide in river sediments collected at the Metropolitan Area of São Paulo (MASP) City and at the Barra Bonita reservoir, located in the Tietê River, 270 km down river from São Paulo City. The concentrations of acid volatile sulfide were 9 to 14 mg kg-1 in the Barra reservoir and between 1.2 and 14 g kg-1 in sediments from Billings, Pirapora and Rasgão reservoirs. This thesis also describes the coupling of Sequential Injection with Monosegmented Flow Analysis (SI-MSFA) for determination of sulfide at typical concentrations in wastewaters. The analytical curves were constructed by in-line dilution of a single stock standard solution. The robustness of the proposed method was checked constructing analytical curves in different working days and comparing the slopes, which had a relative standard deviation of 5.2 % (n = 5) for a concentration window inside the monosegment between 0.17 and 1.0 mg L-1 S2-. The analytical throughput was 38 samples per hour and the limit of detection was 40 µg L-1. The feasibility of the SI-MSFA approach to perform standard additions for S2- determination was also described. Simulated samples analyzed by the proposed method showed recoveries between 70 and 115%, demonstrating the feasibility of the SI-MSFA method to perform in-situ analysis of S2- in automatic monitoring stations.
3

Procedimentos de análise por injeção sequencial para determinação espectrofotométrica de sulfeto em amostras ambientais explorando a formação do azul de metileno / Sequential injection analysis procedure for spectrophotometric determination of sulfide in environmental samples by exploring the formation of methylene blue

Marcelo Solitrenick Pinto Silva 13 March 2003 (has links)
Esta tese demonstra a aplicação da análise por injeção seqüencial (SIA) para determinação de sulfeto utilizando a química da formação do azul de metileno, a qual se baseia em dois reagentes: solução de cloridrato de dimetil p-fenileno diamina (DMPD) 3,63 mmol L-1 em meio de HCI 1,1 mol L-1 e solução de cloreto de ferro (III) 19 mmol L-1, também em meio de HCI 1, 1 mol L-1. Estas soluções foram aspiradas para dentro de uma bobina coletora do sistema SIA como duas zonas de reagente, entre as quais aspirava-se a solução da amostra. Em condições otimizadas o limite de detecção foi calculado em 40 µg L-1 de S2-, com uma faixa dinâmica de resposta linear entre 0,05 e 2,0 mg L-1 . Esta faixa linear pode ser ampliada até 32 mg L-1 utilizando-se uma etapa de diluição in-line para concentrações maiores do que 2,0 mg L-1 de S2- . As características de robustez do sistema SIA que utiliza uma bomba de pistão, confere alta estabilidade para as curvas analíticas (precisão de 4%), minimizando a trabalhosa preparação de padrões de S2-. O método foi aplicado na determinação de sulfeto volatilizável por ácidos (AVS) em sedimentos coletados em reservatórios da região metropolitana de São Paulo (RMSP) e no reservatório de Barra Bonita no rio Tietê, localizado 270 km a jusante em relação à cidade de São Paulo. As concentrações de AVS foram 9 a 14 mg kg-1 nos sedimentos de Barra Bonita e entre 1,2 e 14 g kg-1 nos sedimentos dos reservatórios Billings, Pirapora e Rasgão. Esta tese também descreve o acoplamento da análise por injeção seqüencial com análise por fluxo monossegmentado (SI-MSFA) para determinação de sulfeto em níveis de concentração típicos de águas residuais. As curvas analíticas foram construídas por diluição in-line de uma única solução padrão. A robustez do método proposto foi verificada construindo-se curvas analíticas em diferentes dias de trabalho e comparando-se os coeficientes angulares, os quais apresentaram um desvio padrão relativo de 5,2% (n=5) para uma faixa de concentração entre 0,17 e 1,0 mg L-1 de S2-. A freqüência de amostragem foi de 38 análises por hora, com um limite de detecção de 40 µg L-1. A adequabilidade do método SI-MSFA para realizar adições de padrão para determinação de S2- também foi descrita. Amostras simuladas foram analisadas pelo método proposto, apresentando taxas de recuperação entre 70 e 115%, demonstrando a adequabilidade do método SI-MSFA para realizar análise in-situ de S2- em estações automáticas de monitoramento. / This thesis demonstrates the application of sequential injection analysis (SIA) to perform sulfide determination using the methylene blue chemistry, based on two reagents: 3.63 mmol L-1 N,N dimethyl-p-phenylene diamine hydrochloride in 1.1 mol L-1 HCI solution and 19 mmol L-1 FeCl3, also in 1.1 mol L-1 HCI. These solutions are aspirated inside the holding coil of the sequential injection system as two reagent zones sandwiching the sample zone. Under optimized conditions, the detection limit was calculated at 40 µg L-1 S2-, with a linear dynamic range from 0.05 to 2 mg L-1 S2-. This linear range can be extended up to 32 mg L-1 using in-line dilution for sulfide concentrations greater than 2 mg L-1. The robust characteristic of the SI system with syringe pump leads to very stable analytical curves (precision of 4%), minimizing the laborious preparation of sulfide standards. The method was applied in the determination of acid volatile sulfide in river sediments collected at the Metropolitan Area of São Paulo (MASP) City and at the Barra Bonita reservoir, located in the Tietê River, 270 km down river from São Paulo City. The concentrations of acid volatile sulfide were 9 to 14 mg kg-1 in the Barra reservoir and between 1.2 and 14 g kg-1 in sediments from Billings, Pirapora and Rasgão reservoirs. This thesis also describes the coupling of Sequential Injection with Monosegmented Flow Analysis (SI-MSFA) for determination of sulfide at typical concentrations in wastewaters. The analytical curves were constructed by in-line dilution of a single stock standard solution. The robustness of the proposed method was checked constructing analytical curves in different working days and comparing the slopes, which had a relative standard deviation of 5.2 % (n = 5) for a concentration window inside the monosegment between 0.17 and 1.0 mg L-1 S2-. The analytical throughput was 38 samples per hour and the limit of detection was 40 µg L-1. The feasibility of the SI-MSFA approach to perform standard additions for S2- determination was also described. Simulated samples analyzed by the proposed method showed recoveries between 70 and 115%, demonstrating the feasibility of the SI-MSFA method to perform in-situ analysis of S2- in automatic monitoring stations.

Page generated in 0.1026 seconds