Spelling suggestions: "subject:"águas residual - tratamento"" "subject:"águas residual - ratamento""
1 |
Reutilização de resíduos líquidos com corantes reativos após descoloração enzimática /Chiarello, Luana Marcele, Barcellos, Ivonete Oliveira, Universidade Regional de Blumenau. Programa de Pós-Graduação em Química. January 2012 (has links) (PDF)
Orientador: Ivonete Oliveira Barcellos. / Dissertação (mestrado) - Universidade Regional de Blumenau, Centro de Ciências Exatas e Naturais, Programa de Pós-Graduação em Química.
|
2 |
Tratamento e reutilização de efluentes têxteis gerados nos tingimentos de tecidos de algodão /Quadros, Silvana Stefanel de, Barcellos, Ivonete Oliveira, Universidade Regional de Blumenau. Programa de Pós-Graduação em Química. January 2005 (has links) (PDF)
Orientadora: Ivonete Oliveira Barcellos. / Dissertação (mestrado) - Universidade Regional de Blumenau, Centro de Ciências Exatas e Naturais, Programa de Pós-Graduação em Química.
|
3 |
Reuso do efluente do processo de mercerização no tingimento de malha de algodão /Ferrari, Rubens, 1969-, Andreaus, Jürgen, 1965-, Universidade Regional de Blumenau. Programa de Pós-Graduação em Engenharia Ambiental. January 2007 (has links) (PDF)
Orientador: Jürgen Andreaus. / Dissertação (mestrado) - Universidade Regional de Blumenau, Centro de Ciências Tecnológicas, Programa de Pós-Graduação em Engenharia Ambiental.
|
4 |
Remoção de corante disperso não fixado de fibras de poliéster através de uso de enzimas oxidoredutases para redução de águas de lavação /Schmitt, Sharlene, Valle, José Alexandre Borges, Universidade Regional de Blumenau. Programa de Pós-Graduação em Engenharia Ambiental. January 2010 (has links) (PDF)
Orientador: José Alexandre Borges Valle. / Dissertação (mestrado) - Universidade Regional de Blumenau, Centro de Ciências Tecnológicas, Programa de Pós-Graduação em Engenharia Ambiental.
|
5 |
Avaliação de micropoluentes emergentes em esgotos e águas superficiais / Evaluation of emerging organic micropollutants in sewage and surface waterSouza, Neyliane Costa de 11 1900 (has links)
SOUZA, N. C. de. Avaliação de micropoluentes emergentes em esgotos e águas superficiais. 2011. 166 f. Tese (Doutorado em Engenharia Civil - Saneamento Ambiental) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2011. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2012-02-28T19:43:37Z
No. of bitstreams: 1
2011_tese_ncsouza.pdf: 3004356 bytes, checksum: 1fb2dc46b73bd3f09a8920c22635e2a8 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2012-02-28T19:44:35Z (GMT) No. of bitstreams: 1
2011_tese_ncsouza.pdf: 3004356 bytes, checksum: 1fb2dc46b73bd3f09a8920c22635e2a8 (MD5) / Made available in DSpace on 2012-02-28T19:44:35Z (GMT). No. of bitstreams: 1
2011_tese_ncsouza.pdf: 3004356 bytes, checksum: 1fb2dc46b73bd3f09a8920c22635e2a8 (MD5)
Previous issue date: 2011-11 / In Brazil, studies evaluating emerging micropollutants in environmental matrices such as sewage and hospital wastewater, as well as surface waters, are still quite incipient as well as the removal of these compounds in low cost Wastewater Treatment Plants (WWTPs) such as stabilization ponds, as well as in activated sludge systems or anaerobic/aerobic compact systems. This work aimed to investigate the presence of micropollutants in environmental matrices such as sewage and hospital wastewaters, and in surface waters. Additionally, this study evaluated the removal of these compounds in low-cost WWTPs and studied the advanced oxidation process (AOP) – UV/H2O2 – as a post-treatment option. The main emerging micropollutants studied were: 2,4,6-trichlorophenol, pentachlorophenol, caffeine (CAF), dipyrone (DIP), sodium diclofenac (DCF), bis (2-ethylhexyl) phthalate (DEHP), estrone (E1), 17β-estradiol (E2), estradiol acetate (EA2), 17α-ethinyl estradiol (EE2) and cholesterol (CHO). The samples were collected from WWTPs located in Fortaleza and its metropolitan region. The receiving surface waters investigated were: Maranguapinho River and Paupina Creek. For the pre-concentration studies of micropollutants, solid phase extraction (SPE) with C-18 cartridges was used, as well as the liquid-liquid extraction (LLE) method. The SPE technique was the most efficient method in concentrating the majority of emerging micropollutants, and the LLE proved to be the best technique for organochlorine compounds. Optimization studies were performed to detect the ideal conditions to determine the compounds by using gas chromatography (GC) and gas chromatography-mass spectrometry (GC/MS) techniques. In all wastewater samples pharmaceuticals and endocrine disrupting compounds were identified, and the range of effluent concentrations were: CAF (3.0-15.8 μg/L), DIP (0.3 μg/L), DCF (1.9 μg/L), DEHP (0.01-8.5μg/L), E1 (0.04-1.7 μg/L), E2 (0.03-4.0 μg/L), EA2 (0.14-9.3 μg/L), EE2 (1.0 μg/L) and CHO (0.01-6.2 μg/L). Endocrine disrupting compounds were identified in the Maranguapinho River and Paupina Creek. The wastewater treatment in the WWTPs was not enough for the complete removal of all micropollutants studied; however, the efficiency level for most of compounds was above 50%. Regarding the evaluation in stabilization ponds systems, the study revealed good removal of micropollutants in systems composed of anaerobic pond followed by facultative and maturation ponds, in which the lowest efficiency levels were verified when a single facultative pond was present. The evaluation of the AOP as a post-treatment option by multivariate factorial design showed that the optimal conditions for the removal of emerging micropollutants were acidic pH (pH 3), hydrogen peroxide concentration above 400 mg/L and hydraulic retention times in the reactor above 50 minutes. / No Brasil, estudos de avaliação de micropoluentes emergentes em matrizes ambientais como esgotos sanitários e hospitalares, e corpos de água, ainda são bastante incipientes, assim como a remoção desses compostos em Estações de Tratamento de Esgotos (ETEs) de baixo custo como lagoas de estabilização, assim como em sistemas de lodos ativados e sistemas anaeróbio-aeróbio compactos. O presente trabalho teve como objetivo geral investigar a presença de micropoluentes em matrizes ambientais como esgotos sanitários e hospitalares, e água superficial, avaliar a remoção destes compostos em ETEs de baixo custo e aplicar o processo de oxidação avançada (POA) UV/H2O2 como opção de pós-tratamento. Os principais micropoluentes emergentes estudados foram: 2,4,6-triclorofenol, pentaclorofenol, cafeína (CAF), dipirona (DIP), diclofenaco de sódio (DCF), bis (2-etil-hexil) ftalato (DEHP), estrona (E1), 17β-estradiol (E2), β-estradiol 17-acetato (EA2), 17α-etinilestradiol (EE2) e colesterol (COL). As amostras foram coletadas em ETEs localizadas em Fortaleza e em sua região metropolitana. Os corpos receptores investigados foram o Rio Maranguapinho e o Riacho Paupina. Para a pré-concentração dos micropoluentes utilizou-se extração em fase sólida (SPE) com cartuchos C-18 e extração líquido-líquido (ELL). A SPE foi a técnica mais eficiente na concentração da maioria dos micropoluentes emergentes, e a ELL se mostrou a melhor técnica para compostos organoclorados. Foram realizados estudos de otimização das condições de detecção dos compostos pelo uso de técnicas de cromatografia gasosa acoplada à espectrometria de massas (GC/MS). Foram identificados compostos farmacêuticos e desreguladores endócrinos em todas as amostras de esgotos com as seguintes faixas de concentrações efluentes: CAF (3,0-15,8 μg/L), DIP (0,3 μg/L), DCF (1,9 μg/L), DEHP (0,01-8,5μg/L), E1 (0,04-1,7 μg/L), E2 (0,03-4,0 μg/L), EA2 (0,14-9,3 μg/L), EE2 (1,0 μg/L) e COL (0,01-6,2 μg/L). Nos dois corpos receptores estudados (Rio Maranguapinho e Riacho Paupina) foram identificados desreguladores endócrinos. Os tratamentos realizados pelas ETEs não foram suficientes para remoção total de todos os micropoluentes estudados, no entanto, a eficiência para a maioria dos compostos foi acima de 50%. Em se tratando da avaliação em sistemas de lagoas de estabilização, o estudo revelou boas eficiências de remoção em sistemas constituídos de lagoa anaeróbia seguida de facultativa e de maturação, sendo os menores valores de remoção alcançados quando uma única lagoa facultativa primária estava presente. A avaliação do uso do POA por meio do planejamento fatorial multivariado revelou que as melhores condições para remoção de micropoluentes emergentes foram pH ácido (pH 3), concentração de peróxido de hidrogênio acima de 400 mg/L e tempos de detenção hidráulica no reator acima de 50min.
|
6 |
Uso de efluente sanitário de complexo hospitalar na irrigação de roseira / Use of sanitary wastewater from hospital complex for irrigation of rosesMarinho, Luccas Erickson de Oliveira, 1983- 16 August 2018 (has links)
Orientador: Bruno Coraucci Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-16T21:44:59Z (GMT). No. of bitstreams: 1
Marinho_LuccasEricksondeOliveira_M.pdf: 4263406 bytes, checksum: 357f9f54025ad85da69e60a2418e4721 (MD5)
Previous issue date: 2010 / Resumo: A água reciclada oriunda de tratamento de esgotos caracterizados como domésticos, de origem domiciliar, hospitalar ou de centros de saúde pode ser usada para fins não potáveis como agricultura, jardinagem, parques públicos, irrigação de campos e recarga de aqüífero. O uso de efluente sanitário tratado, além de reduzir os impactos ambientais aos corpos d'água e ao solo, possui atrativos do ponto de vista agronômico, pois e uma forma de reciclagem de nutrientes e de água. A cultura escolhida para avaliação da pratica foi a roseira, que e considerada uma das plantas ornamentais mais sensíveis ao estresse ambiental, e foi observada como planta-teste quando submetida a irrigação com efluente sanitário de complexo hospitalar tratado e condicionado. O plantio foi feito em solo preparado sob ambiente protegido no Campus da Unicamp, em Campinas-SP. O efluente utilizado na irrigação era proveniente de um sistema simplificado de tratamento de esgoto domestico. O sistema de irrigação utilizado foi o de gotejamento. O solo foi monitorado quanto ao pH, CE, Na, Ca, Mg, K, P, foi feita a determinação da RAS, alem dos teores totais de Cd, Cr, Cu, Ni, Zn e Pb. O produto colhido foi avaliado conforme os padrões comerciais, atraves da qualidade e produtividade. O solo não apresentou diferença estatística comparando-se os tratamentos empregados na pesquisa tanto quando avaliando se a fertilidade do solo quanto aos teores de metais pesados. Não houve diferença estatística entre a qualidade da colheita e a produtividade foi maior quando empregado o efluente como fonte de água para irrigação durante 18 meses de pesquisa. Portanto o efluente utilizado no trabalho pode ser utilizado como fonte de água de irrigação sem causar prejuízos a produtividade e qualidade da cultura / Abstract: Reclamed water from sewage treatment plants utilizing domestic, home houses or health centers can be used for non-potable aplications such as agriculture, gardening, public parks, field irrigation and aquifer recharge. The use of treated sanitary wastewater, besides reducing environmental impacts to water bodies and soil, also has agronomic attractive, since it is a way of recycling nutrients and water. In this sense, the culture chosen for evaluation of this practice was the rose, which is considered an ornamental plant more susceptible to environmental stress, and was evaluated as a test plant when was being subjected to irrigation with treated and conditioned sanitary effluent from a hospital center. The culture was done in prepared soil in a protected environment on the campus of Unicamp, Campinas-SP. The effluent used for irrigation was from a simplified system for domestic wastewater treatment. The irrigation system was for drip. The soil was monitored for fertility (pH, EC, Na, Ca, Mg, K, P), determination of the SAR, and total contents of Cd, Cr, Cu, Ni, Zn and Pb The harvested crop was rated as commercial standards, through quality and productivity. The soil showed no statistical difference when comparing the treatments used in the research both when evaluating the soil fertility or the levels of heavy metals. There was also no statistical difference concerning the quality of the crop and the productivity was higher when using this source of water for irrigation during the 18 months of research. Therefore the effluent used in this work can be used as a source of water irrigation without causing damage to productivity and crop quality / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
|
7 |
Processo oxidativo avançado UV/H2O2 na oxidação da carbamazepina : avaliação por ensaios respirometricos e ecotoxicologicos / Advanced oxidation process UV/H2O2 in the oxidation carbamazepine : assessment with respirometry and ecotoxicological assaysMartins, Armando Carvalho de Oliveira 13 August 2018 (has links)
Orientador: Alexandre Nunes Ponezi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-13T11:19:54Z (GMT). No. of bitstreams: 1
Martins_ArmandoCarvalhodeOliveira_M.pdf: 1218959 bytes, checksum: 89c4972bf88120caa1add6b7b1eb515a (MD5)
Previous issue date: 2009 / Resumo: O efeito da poluição é resultado inerente da ocupação humana com grande impacto ao ambiente. Um problema atual é a contaminação dos corpos d'água com produtos de origem industrial, agrícola e produtos de origem farmacológica e de cuidado pessoal. Os fármacos são considerados contaminantes ambientais devido a estas moléculas serem biologicamente ativas. Neste trabalho foi estudada a biodegradabilidade direta da carbamazepina, sua degradação por processo oxidativo avançado e por processo oxidativo avançado seguido de respirometria. Foi utilizado como metodologia a cromatografia em camada delgada, cromatografia líquida de alta eficiência, análises toxicológicas, respirométricas, demanda química de oxigênio e carbono orgânico total. A avaliação do potencial de biodegradação direta da carbamazepina por microrganismos provenientes do lodo ativado e do solo não apresentaram resultados satisfatórios. A melhor concentração de carbamazepina a ser utilizada no processo oxidativo, foi de 10 ppm. As análises de carbono orgânico total, referente ao processo de oxidação em reator de ultravioleta com peróxido de hidrogênio, realizadas após o tratamento mostraram que a taxa de remoção de carbono da solução foi de 1%. A análise da demanda química de oxigênio, realizada a partir das amostras geradas do reator nos tempos de reação de 5, 15, 30, 45 e 60 minutos não apresentou qualquer mudança significativa. Os ensaios de respirometria (biodegradação) mostraram uma degradação de aproximadamente 1% do composto químico para todos os tratamentos com ultravioleta com peróxido de hidrogênio utilizados. Nos testes de biodegradabilidade os microrganismos não foram capazes de utilizar o fármaco como fonte de carbono e energia mesmo após o tratamento com ultravioleta com peróxido de hidrogênio. A avaliação do desenvolvimento dos microrganismos durante o ensaio de biodegradação apresenta decréscimo acentuado do número de microrganismos viáveis presentes tanto para o composto puro como também para os ensaios realizados após o tratamento com ultravioleta com peróxido de hidrogênio. Os subprodutos gerados no processo oxidativo avançado apresentam efeitos tóxicos agudos para a Ceriodaphinia dúbia e Vibrio fischeri nos ensaios toxicológicos. / Abstract: Pollution is a direct result of human occupation. Since the big human conglomerates appeared became clear its harmfulness to the environment. Today there is a growing concern with water pollution by industrial, agricultural, pharmaceutical and personal care products. Pharmaceutical and personal care products contaminates the water in the domestic effluent, or in an inappropriate disposal of then in urban trash. The pharmaceutical products are considered environmental contaminants because their molecules are biologically actives. In this study the direct biodegradability of carbamazepine, its degradation by advanced oxidation process and advanced oxidation process followed by respirometry were evaluated. The total organic carbon, chemical oxygen demand, thin layer chromatography, high pressure liquid chromatography and respirometry were utilized to obtain the results of this work. The biodegradability results by microorganisms in soil and silt were not satisfying. An optimal concentration of 10ppm of carbamazepina was used in the advanced oxidation process. The total organic carbon results of the advanced oxidation process in UV/H2O2 reactor after the treatment revealed a removal rate of 1%. The respirometry assays showed less than 1% degradation of the chemical compound for all UV/H2O2 treatment. The results indicate that the microorganisms were not able to use the pharmaceutical product as a carbon and energy source even after UV/H2O2 treatment. The evaluation of microscopic development during the biodegradation assays revealed a drastic fall in the number of viable microorganisms presents in the pure compound as well as after the advanced oxidation process. The toxicological assays showed that the advanced oxidation process generated sub products and have acute toxicological effects for Ceriodaphinia dúbia and Vibrio fischeri. / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
|
8 |
Estudo da inativação fotodinâmica de Escherichia coli em água utilizando azul de metileno e rosa de bengalaSantos, Renata Oliveira 05 March 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This work aimed to develop a procedure for disinfecting water by photodynamic inactivation of microorganisms and subsequent removal of photosensitizers. The Escherichia coli photoinactivation was performed using PHLS (Policromatic Halogen Light System) light system irradiation, Methylene Blue and Rose Bengal as photosensitizers, cationic and anionic dyes , respectively. The phase separation between the photosensitizers and the analyzed sample was studied by coagulation, being used the crushed seeds of Moringa oleifera, Chitosan powder and commercial Aluminum Sulphate. All experiments were performed previously in samples of E. coli (ATCC 25922) prepared with a turbidity of about 01 on the Mac Farland scale and later in a sample of effluent from the Sewage Treatment Plant of Uberlândia - MG. The results were quite significant as much photoinactivation as the photosensitizers removal, being Moringa oleifera the best coagulant used, able to remove, from effluent sample, 96.9% Rose Bengal and 75.9% Methylene Blue, both at a concentration of 3,91x10-5 mol L-1. / O presente trabalho visou desenvolver um procedimento para a desinfecção de águas através da inativação fotodinâmica de micro-organismos e posterior remoção dos fotossensitizadores. A fotoinativação de Escherichia coli foi realizada utilizando sistema de irradiação luminosa PHLS (Policromatic Halogen Light System) e Azul de Metileno e Rosa de Bengala como fotossensitizadores, corantes catiônico e aniônico, respectivamente. A separação de fases entre os fotossensitizadores e a amostra analisada foi estudada através de coagulação, sendo utilizadas as sementes de Moringa oleífera trituradas, Quitosana em pó e Sulfato de alumínio comercial. Todos os experimentos foram realizados previamente em amostras de E. coli (ATCC: 25922) preparadas com turvação de aproximadamente 01 na escala de Mac Farland e posteriormente em amostra de efluente proveniente da Estação de Tratamento de Esgoto de Uberlândia - MG. Os resultados obtidos foram bastante expressivos tanto na fotoinativação, quanto na remoção dos fotossensitizadores, sendo a Moringa oleífera o melhor coagulante utilizado, tendo conseguido remover da amostra de efluente 96,9% do Rosa de Bengala e 75,9% do Azul de Metileno, ambos em uma concentração de 3,91x10-5 mol L-1. / Mestre em Química
|
9 |
Identificação dos produtos de degradação química/eletroquímica do herbicida ametrina / Identification of degration products of chemical/electrochemical herbicide ametrineBeati, André Augusto Gutierrez Fernandes 16 August 2018 (has links)
Orientadores: Marcos Roberto de Vasconcelos Lanza, Rodnei Bertazzoli / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-16T20:01:04Z (GMT). No. of bitstreams: 1
Beati_AndreAugustoGutierrezFernandes_D.pdf: 4569837 bytes, checksum: 6c1637bdb8e9ad2c61b0b69c8e02f7a1 (MD5)
Previous issue date: 2010 / Resumo: Neste trabalho foram estudados a identificação de produtos de degradação da ametrina (AME), agrotóxico utilizado em larga escala na agroindústria canavieira. A melhora no tratamento das condições ambientais é de suma importância para as regiões agrícolas, já que a contaminação do solo e das águas subterrâneas é quase inevitável. Em relação às indústrias que produzem/formulam os agrotóxicos, um tratamento alternativo é interessante, pois os Processos Oxidativos Avançados (POAs), e dentre esses, o emprego da Tecnologia Eletroquímica. Uma vez os parâmetros definidos podem gerar a combustão total da carga orgânica, ou geral produtos de degradação, que podem ser identificados, e assim, entender melhor o processo de degradação da AME. Desta maneira foram realizadas reações de oxidação parcial do herbicida utilizando a adição de H2O2 em uma solução contendo 100 mg L-1 de AME e catalisadas com Fe2+ em diferentes pH e temperatura. Os produtos foram identificados por um espectrômetro de massa, Ion-Trap com ionização por electrospray (ESI). O produto 4-amino-6-(metilamina)-1,3,5-triazin-2-ol (m/z 141) fora identificado, praticamente em todos os ensaios realizados. A melhor condição experimental para oxidar quimicamente a AME, ocorreu na proporção de 20 % (v/v) de H2O2, pH 7 e temperatura de 65 °C. Outra maneira de estudar a degradação da AME foi controlar a geração do H2O2 eletrogerado, desta maneira as degradações eletroquímicas do herbicida foram realizadas utilizando 200 mg L-1 do principio ativo a partir de uma solução comercial (Herbipak®). Eletrólises a potencial constante foram realizadas de -0,7 V ? E ? -1,2 V vs Ag/AgCl para geração de H2O2, alcançando o máximo da concentração de 508 mg L-1 para o potencial de -0,9 V vs. Ag/AgCl. O monitoramento da AME analisadas por CLAE, apresentou uma taxa de decaimento da concentração de 55% via geração de H2O2, com redução de 45% do COT quando utilizado a eletrossíntese H2O2/Fe2+. Estes ensaios de degradação também monitoraram a degradação da AME via CI, identificando a formação de íons NO3- e NO2-. A identificação da formação dos produtos de degradação da AME foi realizada por CG-EM/EM. / Abstract: In this study the identification of degradation products ametrina (AME), pesticides used on a large scale in the sugar industry. The improvement in the treatment of environmental conditions is of paramount importance to the agricultural regions, since the contamination of soil and groundwater contamination is almost inevitable. In relation to industries producing/formulate pesticides, an alternative treatment is interesting because the Advanced Oxidation Processes (AOPs), and among these, the use of Electrochemical Technology. Once the parameters set can generate combustion total organic content, or general degradation products, which can be identified, and thus better understand the degradation process of AME. Thus were partial oxidation reactions of the herbicide using the addition of H2O2 in a solution containing 100 mg L-1 of AME and catalyzed with Fe2+ at different pH and temperature. The products were identified by mass spectrometry, Ion-Trap electrospray ionization (ESI.) The product 4-amino-6-(methylamine)-1,3,5-triazine-2-ol (m/z 141) was identified, almost all trials. The best experimental condition to oxidize chemically AME, occurred at a rate of 20% (v/v) H2O2, pH 7 and temperature of 65°C. Another way to study the degradation of AME was controlling the generation of electrogenerated H2O2, thus the electrochemical degradation of the herbicide were performed using 200 mg L-1 of the active principle from a commercial solution (Herbipak®). Constant potential electrolyses were performed from -0.7 V ? E ? -1.2 V vs. Ag / AgCl for generation of H2O2, reaching the maximum concentration of 508 mg L-1 for the potential of -0.9 V vs Ag/AgCl. The monitoring of AME analyzed by HPLC, showed a rate of decay of the concentration of 55% via H2O2 generation, with 45% reduction of TOC when used at eletrossíntese H2O2/Fe2+. These tests also monitored the degradation via AME IC, identifying the formation of NO3- and NO2-. The identification of the formation of degradation products was performed by AME CG-MS/MS. / Doutorado / Materiais e Processos de Fabricação / Doutor em Engenharia Mecânica
|
10 |
Avaliação de aspectos da colmatação e descolmatação de sistemas alagados construídos de escoamento horizontal subsuperficial / Evaluation of aspects of clogging and reverse clogging in constructed wetland systems of horizontal subsurface flowMiranda, Suymara Toledo 21 July 2014 (has links)
Made available in DSpace on 2015-03-26T13:23:56Z (GMT). No. of bitstreams: 1
texto completo.pdf: 1268005 bytes, checksum: 59ae839bbe2156f8abdb0db2d385bff2 (MD5)
Previous issue date: 2014-07-21 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Constructed wetland systems of horizontal subsurface flow (CW-SSHF) are systems used in wastewater treatment. The main operational problem of these systems is the clogging of the porous medium, a phenomenon called "clogging". With this study, we aimed to characterize the composition of the material responsible for clogging the porous medium, CWs-SSHF and evaluate reverse clogging in these systems by adding nutrient solution nitrogen-based. To make possible this study, we used six CWs-SSHF that were completely clogged after being used in the treatment of swine wastewater. The operating conditions of these systems were called: CW-C (CW-SSHF 1 and CW-SSHF 4, uncultivated, ie controls); CW-T (CW-SSHF 2 and CW-SSHF 5 cultured with tifton 85 (Cynodon spp.)) and CW-A (CW-SSHF 3 and CW-SSHF 6 cultured with alternantera (Alternanthera philoxeroides)). The characterization of clogging material of porous medium from each experimental indicated that, for the most part, was composed of fixed solids (95, 84 e 82% in CW-C, CW-T e CW-A, respectively). It was observed that the cultivated CWs accumulated/produced more volatile solids that not cultivated systems, and the contribution of dead plant tissue may have been the main source of clogging in SACs-EHSS studied. To evaluate the effects of application of nutrient solution in the reverse clogging CWs-EHSS process, we carried out a comparison between sets of solids (total solids -TS, volatile solids - TVS and fixed solids -TFS) and readily oxidizable carbon (OCFO), before and after treatment, and performed hydraulic conductivity tests in saturated porous media, and monitoring the runoff in the gravel of the systems. The results indicated that the passage of the nutrient solution for 55 days, in the gravel of the SACs-EHSS provided reductions of 11 and 33%, respectively TVS content of fine material from clogging CW-T and CW-A. With respect to gross material, the reduction was even greater, being 33% for the CW-T and 62% for a CW-A. The hydraulic conductivity of saturated medium, made over the beds (1st, 2nd and 3rd thirds) before and after the passage of the nutrient solution in SACs, indicated, respectively, increases of 7%, 13% and 0,1% in CW-C, 21%, 11% and 7% CW-T. In the CW-A increase was evidenced only in 1st third (52%) and in the 2nd third (6%), while in the 3rd third there was a decrease in hydraulic conductivity in porous media. The reduction in the length of the gravel that had runoff nutrient solution occurred gradually, over time of treatment and were not observed any more runoff from the fourth week of the passage of the nutrient solution, the CW-C , and from the fifth week, the CW-T. In the CW-A, despite 72% reduction was observed in the seventh week of therapy, did not occur during the evaluation period, cessing, altogether, the runoff in these beds. Based on the results obtained, it was found that the passage of the nutrient solution based nitrogen contributed to reduction in surface runoff in the gravel, having been the reduction in the concentration of dead organic material present in the superficial layers, one of the main factors for this decrease. / Os sistemas alagados construídos de escoamento horizontal subsuperficial (SACs-EHSS) são sistemas utilizados no tratamento de águas residuárias. O principal problema operacional desses sistemas é o entupimento do meio poroso, cujo fenômeno é denominado de colmatação. Com a realização deste estudo, objetivou-se caracterizar a composição do material responsável pela colmatação do meio poroso dos SACs-EHSS e avaliar a descolmatação desses sistemas, por adição de solução nutritiva à base de nitrogênio. Para possibilitar este estudo, utilizou-se seis SACs-EHSS que encontravam-se totalmente colmatados após terem sido utilizados no tratamento de águas residuárias da suinocultura. As condições operacionais desses sistemas foram denominadas de SAC-C (SAC- EHSS 1 e SAC-EHSS 4, não cultivados, ou seja controles); SAC-T (SAC-EHSS 2 e SAC-EHSS 5 cultivados com capim tifton 85 (Cynodon spp.)) e SAC-A (SAC- EHSS 3 e SAC-EHSS 6 cultivados com alternantera (Alternanthera philoxeroides)). A caracterização do material colmatante do meio poroso de cada unidade experimental indicou que, em sua maior parte, foi composto por sólidos fixos (95, 84 e 82% nos SAC-C, SAC-T e SAC-A, respectivamente). Observou-se que os SACs cultivados acumularam/produziram mais sólidos voláteis que os sistemas não cultivados, sendo que a contribuição de tecido vegetal morto pode ter sido a principal fonte da colmatação nos SACs-EHSS estudados. Para avaliação dos efeitos da aplicação da solução nutritiva no processo de descolmatação dos SACs-EHSS, realizou-se uma comparação entre as séries de sólidos (sólidos totais - ST, sólidos voláteis totais - SVT e sólidos fixos totais - SFT) e carbono facilmente oxidável (COfo), antes e após o tratamento, além de efetuados testes de condutividade hidráulica no meio poroso saturado, e do acompanhamento no escoamento superficial no leito dos sistemas. Os resultados indicaram que a passagem da solução nutritiva, por 55 dias, no leito dos SACs- EHSS proporcionou reduções de 11 e 33%, respectivamente, no teor de SVT do material fino colmatante dos SAC-T e SAC-A. No que se refere ao material grosseiro, essa redução foi ainda maior, sendo de 33% para o SAC-T e 62% para o SAC-A. A condutividade hidráulica em meio saturado, efetuadas ao longo dos leitos (1o, 2o e 3o terços), antes e depois da passagem da solução nutritiva nos SACs, indicaram, respectivamente, aumentos, de 7%, 13% e 0,1% no SAC-C, 21%, 11% e 7% no SAC-T. No SAC-A foi evidenciado aumento apenas no 1o terço (52%) e no 2o terço de (6%), enquanto no 3o terço houve diminuição na condutividade hidráulica no meio poroso. A redução no comprimento do leito em que havia escoamento superficial da solução nutritiva ocorreu de forma gradativa, ao longo do tempo de tratamento, não tendo sido mais observado qualquer escoamento superficial, a partir da quarta semana de passagem da solução nutritiva, no SAC-C, e a partir da quinta semana, no SAC-T. No SAC-A, apesar de ter sido observada redução de 72%, na sétima semana de tratamento, não ocorreu, no período de avaliação, cessamento, por completo, do escoamento superficial nesses leitos. Com base nos resultados obtidos, verificou-se que a aplicação da solução nutritiva à base de nitrogênio contribuiu para redução no escoamento superficial nos leitos, tendo sido a redução na concentração de material orgânico morto, presente nas camadas superficiais, um dos principais fatores para essa diminuição.
|
Page generated in 0.0991 seconds