• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 291
  • 6
  • 6
  • 6
  • 6
  • 4
  • 3
  • 2
  • Tagged with
  • 298
  • 298
  • 298
  • 117
  • 100
  • 97
  • 83
  • 70
  • 51
  • 47
  • 44
  • 43
  • 41
  • 39
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Preparação e caracterização de membranas impregnadas com nanopartículas de prata e cobre e sua aplicação na desinfecção da água

Biron, Dionisio da Silva 24 February 2016 (has links)
Submitted by Ana Guimarães Pereira (agpereir@ucs.br) on 2016-06-21T16:37:36Z No. of bitstreams: 1 Dissertacao Dionisio da Silva Biron.pdf: 4968193 bytes, checksum: b3110cb668f93c8ff3069f7d944b6668 (MD5) / Made available in DSpace on 2016-06-21T16:37:36Z (GMT). No. of bitstreams: 1 Dissertacao Dionisio da Silva Biron.pdf: 4968193 bytes, checksum: b3110cb668f93c8ff3069f7d944b6668 (MD5) Previous issue date: 2016-06-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, CAPES
142

Tratamento de águas residuárias por alagados construídos de fluxo subsuperficial horizontal, utilizando Vetiver (Chrysopogon zizanoides L.): avaliação e desempenho de três leitos distintos

Dreifus, Thais von [UNESP] 16 July 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-07-16Bitstream added on 2014-06-13T19:59:10Z : No. of bitstreams: 1 dreifus_t_me_bauru.pdf: 1757987 bytes, checksum: 3ca7db6f1e016a17e90f4944649089cc (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / Esta pesquisa visa o tratamento de águas residuárias através de Sistemas de Alagados Construídos (Westlands) de fluxo subsuperficial e escoamento horizontal. O principal objetivo deste sistema é a remoção da matéria orgânica, uma vez que, a matéria carbonácea presente no esgoto é degradada, tanto aerobicamente por microorganismos que estão aderidos nas raízes das mocrófitas quanto, anaerobicamente pelas bactérias aderidas no substrato do leito filtrante. A estação de tratamento de esgoto por Alagados Construídos está localizada na cidade de Bauru-SP e trata o esgoto produzido pela Moradia Estudantil e pelo Campus do Departamento de Educação Física da Universidade Estadual Paulista Júlio de Mesquita Filho (UNESP). Para uma melhor condição de estudo são utilizadoas três sistemas de leitos com 9m de comprimento por 4,5m de largura e 0,80m de profundidado e inclinação de 1%. Os leitos foram compostos por diferentes substratos: o primeiro, preenchido com brita nº 1, brita nº 3 e areia grossa, o segundo preenchido pedrisco, poliestireno expandido (isopor) moído e reciclado e areia grossa, e o terceiro com brita nº 3 e areia grossa. Com o uso desses diferentes substratos foi possível avaliar em duas etapas de análise, qual deles apresenta os melhores resultados e condições para o tratameto de águas residuárias. A eficiência média de remoção de DBO foi de 85,6% para o leito de brita, 84,2% para o leito de isopor e 85,4% para o leito de areia. A remoção de fosfato teve média de eficiência de 53,3% para o leito de brita, 9,6% para o leito de isopor e 89% para o leito de areia. Para o nitrogênio total Kjeldahl a eficiência média de remoção foi de 7,7% para o leito de brita, 77,0% para o leito de isopor e 75,3% para o leito de areia. No geral todo o sistema se mostrou eficiente para o tratamento de águas residuárias, porém o leito de isopor se destacar por se tratar de um material alternativo e reciclado / This research aims at the wastewater treatment systems using constructed wetlands of subsurface flow and horizontal flow. The main objective of this system is the removal of organic matter, since the carbonaceous matter present in the sewage is dedraded, both aerobically by microorganisms which are adhered on the roots of macrophytes, anaerobically by bacteria adhered to the substrate of the filter bed. The sewage treatment plant by Constructed Westlands is located in the city of Bauru, SP, and treats the sewage produced by the student's home and Deparment of Physical Education, Universidade Estadual Paulista Julio de Mesquita Filho (UNESP). For a better quality studies are used three-bed systems with 9m long by 4.5m wide and 0.80m depth and inclination of 1%. The beds were made up of different substrates: the first, filled with gravel nº 1, nº3 crushed stone and sand, the second filled with gravel, expanded polystyrene (Stryrofoam) and recycled crushed and coarse sand, gravel and the third paragraph 3 and coarse sand. Using these substrates could be assessed in two stages of analysis, which one gives the best results and conditions for the treatment of wastewater. The average efficiency of BOD removal was 85.6% for the bed of crushed rock, 84.2% for the foam bed and 85.4% for the sand bed. The removal efficiency phosphate averaged 53.3% for the gravek bed, the bed to 9.6% of polystyrene and 89% for the sand bed. For the Kjeldahl nitrogen removal efficiency was an average of 75.7% for the bed of gravel, 77.0% for the bed of Styrodom and 75.3% for the sand bed. In general the whole system is efficient for the treatment of wastewater, byr the bed of Styrofoam stand out because it is an alternative material and recycled
143

Avaliação da presença da antineoplásico em água residuária de um hospital oncológico e do sistema de esgotamento sanitário municipal /

Zampieri, Denise Aparecida. January 2013 (has links)
Orientador: Sérgio Vicente Serrano / Banca: Lígia Maria Kerr / Banca: Luciano de Souza Viana / Resumo: Os medicamentos antineoplásicos são uma das classes de produtos farmacêuticos com maior potencial para causar efeitos negativos no ambiente. Várias fontes contribuem para a potencial contaminação do ambiente com esses medicamentos, como emissões da indústria ou descarte direto de produtos farmacêuticos nos domicílios, mas a principal fonte de compostos citostáticos no esgoto ou no ambiente são excreções (urina e fezes) de pacientes em tratamento. Neste estudo foi analisada a presença do antineoplásico 5-fluorouracil (5-FU) e sua quantificação nos efluentes de um hospital oncológico de grande porte e na rede municipal de tratamento de esgoto. Foram analisadas 10 amostras obtidas de um ponto distinto (A), a partir dos efluentes do Hospital de Câncer de Barretos (HCB) e 5 amostras foram obtidas de dois pontos diferentes (B e C) do efluente da Estação de Tratamento de Esgoto (ETE) da cidade de Barretos (ETEB), que tem como destino final o Ribeirão Pitangueiras. Observou-se a presença do fármaco na concentração de 26,7 a 733 μg/L em todas as 10 amostras de água residuária do HCB analisadas, os resultados foram muito superiores aos encontrados em outros trabalhos semelhantes realizados em outros hospitais. Também foi realizado o cálculo das concentrações previstas do agente citostático na água residuária do HCB, utilizando-se parâmetros como o consumo de 5-FU, o consumo de água e a fração de droga excretada na forma não metabolizada. Encontrou-se uma baixa correlação entre a concentração prevista e a concentração medida analiticamente. Esse baixo índice de recuperação pode ter ocorrido decorrente da excreção do fármaco realizada fora do ambiente hospitalar, de uma possível degradação da droga decorrente da instabilidade da molécula ou a perda de uma porção da droga adsorvida na matéria em suspensão dos efluentes. O impacto do descarte de 5-FU no meio ambiente foi avaliado através ... / Abstract: Anticancer drugs represent one of the classes of pharmaceuticals with the greatest potential to cause negative effects on the environment. Contamination of the environment with these drugs may occur from several sources, such as emissions from industry or direct disposal of pharmaceuticals in households, but the main source of cytostatic compounds in the environment occur through sewage emission or excreted fluids (feces and urine) of patients receiving treatment. In this study we analyzed the presence of the antineoplastic 5-fluorouracil (5-FU) and its quantification in the effluents originated from a large oncology hospital and in the local municipal wastewater system. We analyzed 10 samples obtained from a distinct collection site (A), from the effluents of the Barretos Cancer Hospital (HCB). Also, 5 samples were obtained from two different sites (B and C) in the effluent from the Sewage Treatment Plant in Barretos (ETEB), whose final destination is the stream known as Ribeirão Pitangueiras. Presence of 5FU was observed in concentrations ranging from 26.7 to 733 μg/L in all 10 samples of the wastewater originated at the HCB collected at site A. These results were far superior to those found in similar studies performed at other hospitals. The predicted concentrations of the cytostatic agent in the wastewater from HCB was calculated using parameters such as 5-FU consumption, water consumption and the fraction of drug excreted unmetabolized. We found a low correlation between the predicted concentrations and the measured concentrations. This low recovery rate may have occurred due to probable excretion of the drug occuring outside the hospital facilities, since the majority of the patients were ambulatory. Other possibilities are drug degradation due to instability of the molecule and loss of a portion of the drug adsorbed in suspended solid matter of the effluent. The possible impact of the emission of 5-FU to the ... / Mestre
144

Uso de "wetland" construído no tratamento de efluente de ranicultura /

Borges, Fernanda de Freitas. January 2014 (has links)
Orientador: Lúcia Helena Sipaúba Tavares / Banca: Antônio Fernando Monteiro Camargo / Banca: Claudinei da Cruz / Banca: Marta Verardino De Stefani / Banca: Rodrigo Ney Millan / Resumo: O objetivo do trabalho foi avaliar o desempenho de um "wetland" construído no setor de ranicultura para o tratamento do efluente em duas fases da criação de rã-touro. Foram analisadas as variáveis limnológicas e a eficiência de remoção dos nutrientes, a retenção de nutrientes no sedimento e nas macrófitas utilizadas (Eichhornia crassipes, Typha domingensis e Cyperus giganteus), bem como o ganho de biomassa. O tratamento foi eficiente na remoção de nitrato, nitrito, turbidez, fósforo total, sólidos totais suspensos, demanda bioquímica de oxigênio, coliformes termotolerantes, sólidos totais dissolvidos e clorofila a. As maiores cargas de nutrientes foram encontradas na fase de maior quantidade de biomassa de rãs estocada, com menores remoções de fósforo. As macrófitas utilizadas apresentaram ganho de biomassa satisfatório, com concentrações de nutrientes superiores ao do sedimento. As três espécies estocaram mais nutrientes na fase de maior biomassa de animais, com maior carga de nutrientes. Eichhornia crassipes foi a espécie que mais armazenou nitrogênio e fósforo em ambas as fases e com maior ganho de biomassa na fase de maior biomassa de rãs. Das espécies emersas, T. domingensis foi a que apresentou maior ganho de biomassa em ambas as fases, estocando todos os nutrientes na fase de maior biomassa. Ocorreu tendência de diminuição da matéria orgânica do sedimento em ambas as fases da entrada para a saída do "wetland" em função da presença das macrófitas. Este mesmo padrão de redução foi observado em relação aos nutrientes do sedimento. Concluiu-se que o sistema de tratamento implantado foi eficiente na melhoria da qualidade do efluente, com redução de nutrientes e de coliformes termotolerantes. As macrófitas desempenharam papel importante na redução destes componentes e podem ser utilizadas para tratar efluentes da ranicultura / Abstract: The aim of the work was to evaluate the performance of the constructed wetland in frog culture sector for the effluent treatment in two phases of bullfrog culture. Limnological variables and the removal efficiency of nutrients were analyzed, the nutrients retention in the sediment and macrophytes used (Typha domingensis, Cyperus giganteus e Eichhornia crassipes) as well as biomass gain of the same. The treatment was efficient in a nitrate, nitrite, turbidity, total phosphorus, total suspended solids, biochemical oxygen demand, thermotolerant coliforms total, total dissolved solids and chlorophyll a. The high nutrients loads found in the phase of the high biomass frog storage, with lower phosphorus removals. The macrophytes used presented biomass gain satisfactory, with nutrient concentrations above the sediment. The three species stocked more nutrients during the phase of the high biomass frog storage, which high nutrients load. Eichhornia crassipes was the specie that most stored nitrogen and phosphorus in both phases and greater biomass gain in the phase of the high biomass frog storage. From the emerged species, T. domingensis showed the higher biomass gain in both phases, stocking all nutrients in the phase of the high biomass frog storage. There was a tendency of reduction of the organic matter in the sediment in both phases of the inlet to the outlet of wetland due to the presence of macrophytes. This same pattern of reduction was observed relation to the sediment. It was concluded that the treatment system implanted was efficient in improving the quality of the effluent, reducing nutrient and fecal coliform. The macrophytes played an important role in the reduction of such components and may be used to treat effluents of the frog culture / Doutor
145

Biossorção & biodegradação de azo corante : desenvolvimento de processos utilizando resíduos como fonte de microorganismos = Azo dye biosorption & biodegradation : process development with residues as source of microorganisms /

Santos, Graziely Cristina dos. January 2015 (has links)
Orientador: Carlos Renato Corso / Coorientador: Jörgen Forss / Banca: Edério Dino Bidóia / Banca: Dejanira de Franceschi de Angelis / Banca: Cassiana Maria Reganhan Coneglian / Banca: Antonio Sérgio Sapnó Seixas / Resumo: As indústrias têxteis estão entre aquelas que utilizam a maior parte da água em seus processos, além de diversos produtos químicos tais como corantes, detergentes, sais e mordentes. Assim, grandes volumes de efluentes são gerados. O tratamento de águas residuais, às vezes, não é satisfatória. Inúmeros estudos têm sido realizados para encontrar maneiras mais eficientes e de baixo custo para o tratamento de efluentes têxteis. Os tratamentos biológicos têm se mostrado eficazes, uma vez que alguns micro-organismos têm demonstrado sua capacidade de descoloração de efluentes. O presente estudo teve por objetivo avaliar o processo de descoloração do azo corante Direct Red 75 (DR75) 100 mg/L utilizando diferentes fontes de micro-organismos em diferentes sistemas de tratamento, a fim de encontrar uma alternativa eficaz e de baixo custo para o tratamento biológico de efluentes têxteis. Esta avaliação é apresentada em três capítulos brevemente descritos abaixo. O primeiro capítulo mostra a comparação entre dois micro-organismos. O fungo Phanerochaete chrysosporium e a levedura Saccharomyces cerevisiae (fermento biológico) foram os microorganismos utilizados no experimento do 1° capítulo, enquanto um consórcio de microorganismos obtido a partir do inóculo de um biodigestor de alimentos foi utilizado no segundo capítulo. Ambos os experimentos tiveram DR75 como única fonte de carbono e os resultados foram expressos em porcentagem de descoloração e absorbância relativa. A absorbância relativa, obtida pela razão entre a absorbância no comprimento de onda dos grupos cromóforo e azo, sugere a ocorrência de biodegradação pela variação das razões das amostras em comparação com o controle. Os resultados do capítulo 1 mostraram que o tratamento com S. cerevisiae foi mais eficiente que com P. chrysosporium, e a absorbância relativa sugere a ocorrência de biodegradação para ambos. Portanto, o DR75 foi mais... / Abstract: The textile industries are among the ones which use the most water in their processes, in addition to many chemical products such as dyes, detergents, salts and mordant. Thus, great volumes of effluents are generated. Sometimes the wastewater treatment is not satisfactory. Numerous studies have been conducted to find more efficient and low-cost ways to treat textile wastewater. Biological treatments have been proven to be efficient, since some microorganisms have shown the ability to effluent decolorization. The present study aims to evaluate the decolorization process of the azo dye Direct Red 75 (DR75) 100 mg/L by different sources of microorganisms in different treatment systems in order to find an effective and low-cost alternative for the biological treatment of textile wastewater. The evaluation is presented in three chapters briefly described below. First chapter shows the comparison between two microorganisms. The fungus Phanerochaete chrysosporium and the fresh yeast Saccharomyces cerevisiae were the microorganisms used in the experiment of the first chapter, while a consortium of microorganisms obtained from an inoculum of food waste biodigester was used in the second chapter. Both experiments had DR75 as the only carbon source and results expressed as percentage of decolorization and absorbance ratio. Absorbance ratio, obtained by the ratio between the absorbance at a wavelength of the chromophore and azo groups, suggests the occurrence of biodegradation by varying the values of the samples compared to control. The results from chapter 1 showed that treatment with S. cerevisiae was more efficient, than P. chrysosporium and the absorbance ratio suggests the occurrence of biodegradation for both. Therefore, the DR75 was more easily biodegraded by fresh yeast that can be easily acquired, than by single strain of fungus, which seems to be an expensive and labored option for the treatment of textile wastewater. Analysis of ... / Doutor
146

Uso de reator aeróbio de leito fluidizado com circulação como dispositivo de pós-tratamento do efluente de um reator uasb compartimentado tratando esgotos sanitários /

Tetila, Moacir Feba. January 2015 (has links)
Orientador: Tsunao Matsumoto / Co-orientador: Lilizane Lazzarini Albertin / Banca: Dib Gebara / Banca: Miguel Mansur Aisse / Resumo: A pesquisa utilizou um Reator Aeróbio de Leito Fluidizado com Circulação (RALFC) como dispositivo de pós-tratamento do efluente de um Reator UASB Compartimentado (RUC) o qual tratou esgoto sanitário. O RUC foi constituído de 4 tubos de PVC, de diferentes diâmetros, dispostos de forma concêntrica e o RALFC por dois tubos de PVC, de diâmetros diferentes e concêntricos, e uma unidade de sedimentação na parte superior. A pesquisa foi dividida em partida e quatro fases distintas, denominadas fase 1A, 1B, 2A e 2B, nas quais foram variados os parâmetros de operação, como vazão de ar, vazão de efluentes, tempo de detenção hidráulica (TDH) e carga orgânica volumétrica (COV). De modo que durante a pesquisa foi constatado que a melhor fase de tratamento foi quando o RALFC operou com TDH de 4,7 horas e vazão de ar de 300 L/h. O sistema, nessa fase, apresentou um valor médio de DQO efluente de 55 mg/L, a partir de um valor bruto de 607 mg/L em média, gerando uma remoção total de 90%. Os parâmetros de controle como alcalinidade, pH, temperatura e ácidos orgânicos voláteis sempre estivaram dentro das recomendações da literatura, demonstrando uma baixa oscilação. Mesmo assim o sistema não apresentou bom desempenho na remoção de nutrientes, tendo em sua melhor fase de tratamento um efluente com 31 mg/L em média de nitrogênio total, a partir de um valor de entrada de 50 mg/L sendo que a maior parte desse nitrogênio foi removido durante a passagem pelo RUC. Por outro lado para o fósforo, os valores foram de 25 mg/L na entrada e no efluente 14 mg/L, do mesmo modo como ocorreu ao nitrogênio, a maior parte da remoção de fósforo foi realizada pelo RUC / Abstract: The study used an aerobic fluidized bed reactor with circulation (RALFC) as the effluent post-treatment device of a UASB reactor Compartmented (RUC) which treated wastewater. The RUC was consisted of 4 PVC tubes of different diameters arranged concentrically and RALFC two PVC tubes of different diameters and concentric, and a sedimentation unit in the upper part. The research was divided into four distinct phases and starting, called Phase 1A, 1B, 2A and 2B, in which were various operating parameters such as air flow, flow of wastewater, hydraulic retention time (HRT) and volumetric organic load (VOC). So that during the research it was found that the best treatment phase was when the RALFC operated with HRT of 4.7 hours and air flow of 300 L / h. The system, at this stage, had an average effluent COD value of 55 mg/L, from the affluent valor of 607 mg/L on average, there by generating a complete removal of 90%. The control parameters as alkalinity, pH, temperature and volatile organic acids have always been within the recommended by the literature, demonstrating a low oscillation. Even so, the system hasn't showed good performance in the removal of nutrients, in their best treatment stage an effluent with 31 mg/L on average total nitrogen from an input value of 50 mg/L. The most part of nitrogen removal was during passage through the RUC. As for the phosphorus values were 25 mg/L in the effluent input and 14 mg/L, in the same as was the nitrogen, the majority of phosphorus removal was performed by RUC / Mestre
147

Avaliação da eficiência do reator UASB compartimentado (RUC) tratando esgoto sanitário de Ilha Solteira com diferentes carregamentos orgânicos /

Leal, Bruno Quirino. January 2015 (has links)
Orientador: Tsunao Matsumoto / Co-orientador: Liliane Lazzari Albertin / Banca: Milton Dall Aglio Sobrinho / Banca: Katia Sakihama Ventura / Resumo: A aplicação de reatores anaeróbios, como é o caso dos reatores UASB (Upflow Anaerobic Sludge Blanket), passou a ocupar uma posição de destaque, principalmente no Brasil, face às condições ambientais de temperatura favoráveis, baixo custo, simplicidade operacional e baixa produção de sólidos. Dentre os sistemas anaeróbios, tem-se também o Reator Anaeróbio Compartimentado (RAC), um tipo de reator com configuração simples, com divisões internas que buscam separar os tipos de microrganismos da digestão anaeróbia. No presente trabalho estudou-se o comportamento do sistema Reator UASB Compartimentado (RUC), operando com carregamento orgânico volumétrico (COV) em diferentes variações. A melhor condição operacional, relativa à remoção de carga orgânica, foi conseguida quando o RUC foi operado com uma COV de 1,30kgDQO/m3.d (Fase IV), quando apresentou uma média e desvio padrão da eficiência de remoção de DQO de 82,7±7,7% e de DBO de 78,3±3,5%. Quando operando com a maior COV de todas as fases (fase III - 2,17kgDQO/m3.d) apresentou a segunda melhor eficiência de remoção de carga orgânica, com uma média e desvio padrão da eficiência de remoção da DQO de 74,2±8,8% e da DBO de 76,9±8,2%. Com a COV de 1,70kgDQO/m3.d a média e desvio padrão da eficiência de remoção da DQO e DBO foram de 74,2±8,8% e 69,1±6,8%, respectivamente. E com a COV de 0,78kgDQO/m3.d, a média e o desvio padrão da eficiência de remoção de DQO e de DBO foram de 68,9±11% e 69,7±15,7%, respectivamente. Uma desvantagem verificada no RUC foi o arraste de lodo ocasionado pelo aumento da COV, que afetou as características finais do efluente, mas não alteraram significativamente a sua eficiência de remoção da carga orgânica / Abstract: The application of anaerobic reactors, such as the UASB (Upflow Anaerobic Sludge Blanket), has come to occupy a prominent position, especially in Brazil, given the favorable environmental conditions such as temperature, low cost, operational simplicity and low production of sludge. Among the anaerobic systems, there is also the Anaerobic Baffled Reactor (ABR), a type of reactor with simple configuration, with internal divisions that seek to separate the types of microorganisms in anaerobic digestion. Thus, the present work studied the behavior of Compartmented UASB Reactor (CUR), operating with variable volumetric organic loading (VOL). The best operating condition on the removal of organic load was achieved when the CUR was operated with a VOL 1.30kgCOD/m3.day (Phase IV), the CUR had 82.7±7.7% of COD removal efficiency (average and standard deviation) and BOD were 78.3±3.5%. When operating at higher VOL (Phase III - 2.17kgCOD/m3.day) showed the second best organic load removal efficiency with average and standard deviation of the COD removal efficiency of 74.2±8.8% and 76.9±8.2 BOD%. With the VOL 1.70kgCOD/m3d average and standard deviation da the removal efficiency of COD and BOD were 74.2±8.8% and 69.1±6.8%, respectively. And the VOL 0.78kgDQO/m3.day, the average and standard deviation of the COD removal efficiency of BOD and were 68.9±11% and 69.7±15.7%, respectively. A disadvantage found in the CUR was drag sludge resulting from increased VOL, which affected the final characteristics of the effluent, but not significantly modified its removal efficiency of organic load / Mestre
148

Avaliação da remoção de sulfametoxazol, diclofenaco e 17β-estradiol em água por meio de processo oxidativo com cloro /

Souza, Brígida Prieto de. January 2014 (has links)
Orientador: Marcelo Libânio / Banca: Tsunao Matsumoto / Banca: Sergio Francisco de Aquino / Resumo: O objetivo do presente trabalho foi avaliar a remoção de sulfametoxazol, diclofenaco e 17β- estradiol em águas destilada e natural através da oxidação com cloro. Os resultados indicaram que as concentrações iniciais dos microcontaminantes, bem como os tempos iniciais, apresentaram diferenças significativas na remoção dos fármacos em ambas às águas de estudo. Para os ensaios em água destilada, valores de remoção elevados foram encontrados. As águas naturais foram submetidas ao tratamento por clarificação seguido da pós-cloração e os resultados revelaram que a melhor eficiência de remoção deu-se para o diclofenaco, seguido do 17β-estradiol e do sulfametoxazol. De acordo com o estabelecido pela Portaria 2914/11, na qual estipula valores de pH, temperatura e tempos de contato em função do residual de cloro, o tempo correspondente seria até 10 minutos para a pós-cloração, assim, os melhores valores de remoção foram na ordem de 61% para o DCF, 36% para o E2 e 33% para o SMX em água destilada e para água natural esses valores foram de 34% para o DCF, 24% para o E2 e 11% para o SMX. As doses de cloro foram comparadas e para água destilada apenas o DCF apresentou diferenças significativas na eficiência de remoção com o aumento da dose aplicada (3,0 mg.L -1 ), porém para o SMX e E2 não foram observadas diferenças significativas. Observou-se formação de subprodutos já descritos por outros pesquisadores com esses microcontaminantes em água natural, para o SMX e E2 em concentrações de 20 a 90 μg.L -1, não apresentando formação de subprodutos para o DCF, o qual apresentou um dos maiores valores de remoção encontrados neste trabalho. Para cinética de oxidação dos fármacos o tempo de equilíbrio em 30 minutos foi observado para a maioria dos microcontaminantes estudados e todos se adequaram ao modelo cinético de pseudo-segunda ordem, com valores de K 2 na ordem de 0,0133(DCF), 0,0168(SMX) e 0,0326... / Abstract: This study aimed to evaluate removing of sulphamethoxazole, diclofenac and 17β-estradiol on distilled and natural waters by oxidation with chlorine. The results indicated that the initial concentrations of microcontaminants as the inicial time, had a significant differences in both waters of study. For the tests in distilled water, high values of removing were found. The natural water was treated by clarification followed by post-chlorination and the results revealed that the best removal efficiency occurred for diclofenac then 17β-estradiol and sulphamethoxazole. In accordance with the Decree 2914/11, which establishes values of pH, temperature and contact time basis on the residual chlorine, the corresponding time would be up to 10 minutes for post-chlorination, so the best values were on the order of 61% for the DCF, 36% to E2 and 33% for SMX in distilled water, in addition, for natural waters, these values were 34% for the DCF to 24% to E2 and 11% for SMX. The doses of chlorine were compared and in distilled water only the DCF had a significant differences in the removal efficiency with the increase of the applied dose (3.0 mg l -1 ), but in the SMX and E2 no significant differences were observed. It was observed the formation of the sub products of chlorination described by other researchers with these microcontaminants in natural water for SMX and E2 in concentrations from 20 to 90 μg.L-1. However was not found the formation of sub products to DCF, which presented a major removal values found in this study. For the oxidation kinetics of the studied drugs, the ideal contact time was observed in 30 minutes for most studies and all microcontaminants has better adjustment to the kinetic model of the pseudo-second order, with K2 values in the order of 0.0133 (DCF), 0.0168 (SMX) and 0.0326 (E2) in distilled water and 0.0092 (DCF), 0.0025 (SMX) and 0.0479 (E2) in natural water / Mestre
149

Tratamento de efluente de curtume por biofiltro aerado Submerso pré-tratado com microfiltro de membrana /

Bahia, Adilson Silva. January 2014 (has links)
Orientador: Tsunao Matsumoto / Banca: Liliane Lazzari Albertin / Banca: Luis Fernando Rossi Léo / Resumo: Os efluentes do processo de industrialização do couro em curtumes apresentam, além de elevadas concentrações de matéria orgânica em termos de Demanda Química de Oxigênio (DQO) e Demanda Bioquímica de Oxigênio (DBO), altas concentrações de sólidos totais, suspensos e sulfeto, o que torna o tratamento destes efluentes problemático. O objetivo do presente trabalho foi avaliar a biotratabilidade dos efluentes de curtumes por meio do tratamento por Biofiltro Aaerado Submerso (BF) após pré-tratamento por membrana de microfiltração. Os resultados mostraram que pode haver a viabilidade técnica no uso de BF para remoção de matéria orgânica e sulfeto de águas residuárias industriais de curtume, pois atingiram, respectivamente, a remoção 84% e 98 % / Abstract: The effluents from leather tanning process have in addition to high concentrations of organic matter in terms of Chemical Oxygen Demand (COD) and Biochemical Oxygen Demand (BOD), high concentrations of total solids, total suspended solids and sulfide, which makes problematic the treatment of these effluents. The objective of this study was to evaluate the biotreatability of tannery effluent by submerged aerated biofilter after microfiltration membrane pretreatment. The results showed that can be used in the technical feasibility of BF removal of organic sulphide and industrial raw tannery wastewater as it amounted, respectively, removal to 84% and 98% / Mestre
150

Pesquisa de ovos de helmintos em lodo de esgoto oriundo de Campo Grande (MS) após tratamento anaeróbico /

Carrijo, Juliana Rosa. January 2004 (has links)
Orientador: Germano Francisco Biondi / Resumo: O crescimento da população urbana tem produzido um aumento progressivo de resíduos sólidos, que após sofrerem vários processos de desinfecção denominam-se biossólidos. Esta massa orgânica pode ser destinada a diversas finalidades, inclusive como fertilizante agrícola. Entretanto, a disposição deste material deve seguir padrões de qualidade, por apresentar organismos nocivos aos homens e animais. O objetivo deste trabalho foi avaliar a presença de ovos de Taenia sp em lodo de esgoto, previamente tratado em sistema de digestão anaeróbia do tipo Reator Anaeróbio de Lodo Fluidizado (RALF). As amostras de lodo de esgoto foram colhidas na unidade Aero Rancho de Tratamento de Esgoto (ETE) Águas Guariroba, em Campo Grande-MS. O experimento foi dividido em duas fases. Na primeira etapa foram avaliados diferentes tipos de materiais para a escolha do filtro, que possibilitasse a passagem de ovos de Taenia saginata diluídos em água destilada e em lodo líquido. O filtro que melhor se adequou ao experimento foi o Papel higiênico fino folha única. As amostras de lodo de esgoto foram colhidas nos dias 1 (líquido), 15 e 30 (sólido). O lodo colhido foi dividido em alíquotas e filtrado no Papel higiênico fino folha única. Após centrifugação foram avaliadas três lâminas do sedimento por amostra. Os ovos de helmintos foram classificados pelo seu gênero, segundo sua morfologia similar. Foram encontrados ovos com morfologia similar a de ovos de ancilostomídeos, ascarídeos e estrongilídeos em todas as colheitas. Os ovos de Taenia sp, Trichuris, Dipylidium e Strongyloides foram encontrados somente em uma das colheitas. O número de ovos de nematóides prevaleceu sobre os de cestóides. Foram listados ainda, outros organismos como, ácaros, coccídeos, larvas de nematódeos mortas e vivas, leveduras, oocisto e organismos de vida livre. A quantidade de ovos... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The urban population growth have been produced a progressive increase of solid residue that after being through many treatment process is called biossolid. This organic mass can be destination to many use, specially as agricultural fertilizer. However, the disposal of this material must follow some quality standard, for presents harmful organisms to men and animals. The objective of this work was to evaluate the Taenia sp eggs in sewage sludge, previously treated in anerobic digestion process like anaerobic liquid fluid reactor (RALF). The solid sludge samples were collected at the Aero Rancho unit of sludge treatment - Águas Guariroba in Campo Grande, MS. The experiment was devided in two phases. In the first phase were evaluate different kinds of materials to choose the filter, which permit to filter the Taenia saginata eggs diluted with distilled water and in liquid sludge. The filter that better adapted in the experiment was the fine toilet paper one sheet. The sewage sludge samples were collected in the days one (liquid), 15 and 30 (solid). The sludge collected were divided in aliquot and filtered with fine toilet paper one sheet. After, centrifuged it was evaluated three sheet from the sediment for sample. The helminth eggs were classified for their genera, like their similar morphology. There were ancilostomideos, ascarídeos and estrongilídeos eggs in all collect. Eggs of Taenia sp, Trichuris, Dipylidium and Strongyloides were founded only in one of the collects. The nematodes eggs prevailed on the cestodes. Still were listed another organisms as acaros, leavenings, larvae organisms alive and dead, oocists and others organisms. The amount of helminth eggs were varied, indicating the necessity of the sewage sludge pass trough other complementary treatments process, like been revolved and storage for longer period of time. Concluded that the fine... (Complete abstract, click electronic address below). / Mestre

Page generated in 0.0944 seconds