171

Sistema combinado filtro anaerobio-biofiltro aerado submerso : avaliação da partida e da nitrificação de esgoto sanitario / Anaerobic filter-aerated submerged biological filter combined system: start-up and nitrification evaluation in sanitary wastewater

Domingues, Ligia Maria 21 February 2005 (has links)
Orientador: Edson Aparecido Abdul Nour / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-07T10:54:06Z (GMT). No. of bitstreams: 1 Domingues_LigiaMaria_M.pdf: 3689935 bytes, checksum: 34e7505224ee444054fb9606a9599e36 (MD5) Previous issue date: 2005 / Resumo: Este trabalho fundamentou-se na concepção, construção e operação de um sistema combinado anaeróbio-aeróbio, constituído de filtro anaeróbio (FA) e biofiltro aerado submerso (BAS), em escala de laboratório, aplicado ao tratamento de esgoto sanitário. Para atingir o objetivo principal de avaliar o desempenho global do sistema, o trabalho foi dividido em 3 etapas: estudo hidrodinâmico, avaliação da partida e avaliação da nitrificação em diferentes TDH. Baseado numa rotina de monitoramento dos parâmetros físicos, químicos e microbiológicos foi possível avaliar e adequar as condições requeridas para a nitrificação. Verificou-se o desempenho do sistema para diferentes taxas de carregamento volumétrico orgânico e de amônia, relacionando-o com as populações de bactérias nitrificadoras existentes. Constatou-se que remoção de matéria orgânica alcançada foi equivalente para os TDH de 8h (média de 86 ± 6 % para 1,89 ± 0,61 kg DQO/m3.dia com DQO efluente de 87 ± 46 mg O2/L) e 10h (média de 87 ± 4 % para 1,88 ± 0,83 kg DQO/m3 dia com DQO efluente de 89 ± 32 mg O2/L). Para TDH total de 8h (4h de aeração) e taxa de carregamento volumétrico de amônia de 0,33 ± 0,05 kg /m3.dia no BAS a remoção de amônia foi de 27 ± 14 % e a nitrificação completa foi de 20 ± 8 %, para 108 oxidadoras da amônia/g STV e 107 oxidadoras do nitrito/g STV. Para TDH total de 10h (5h de aeração) e taxa de carregamento volumétrico de amônia de 0,39 ± 0,10 kg /m3.dia no BAS a remoção de amônia foi de 47 ± 20 % e a nitrificação foi de 40 ± 19 %, para 1012 oxidadoras da amônia/g STV e 107 oxidadoras do nitrito/g STV. A concepção do sistema FA-BAS operando com TDH de 10 h foi adequada à nitrificação, quando aplicada ao tratamento de esgoto doméstico com média concentração de amônia (em torno de 30 mg/L). Indicou ainda ter grande potencial para tratar esgoto com maior concentração de amônia (acima de 50 mg/L) / Abstract: The present project was based on the conception, construction and operation of an anaerobic-aerobic combined system. This was formed by an anaerobic filter (AF) and an aerated submerged biofilter (ASB), in a laboratory scale, and used for sanitary wastewater. The main objective of this project was to analyze the general performance of the system, and for that, it was divided in 3 parts: hydrodynamic study, start-up evaluation and nitrification analysis in different HRT. Based on a frequent monitoring of physical, chemical and microbiological parameters, it was possible to evaluate and adequate the required conditions for nitrification. The performance of the system for different organic and ammonia volumetric loading rates were verified. Afterwards it was related to the populations of nitrifying bacteria. The system demonstrated organic matter removal not only for HRT of 8 h (average of 86 ± 6% for 1,89 ± 0,61 kg COD/m3.day, with effluent COD of 87 ± 46 mg O2/L) but also for HRT of 10 h (average of 87 ± 4 % for 1,88 ± 0,83 kg COD/m3.day, with effluent COD of 89 ± 32 mg O2/L). For total HRT of 8 h (4 h of aeration) and volumetric loading rates of ammonia of 0,33 ± 0,05 kg/m3.day at ASB, the ammonia removal was 27 ± 14% and the complete nitrification was 20 ± 8 %, for 108 ammonium oxidizers/g TSV and 107 nitrite oxidizers/g TSV. For total HRT of 10 h (5 h of aeration) and volumetric loading rates of ammonia of 0,39 ± 0,10 kg/m3.day at ASB, the ammonia removal was 47 ± 20 % and the complete nitrification was 40 ± 19 %, for 1012 ammonium oxidizers/g TSV and 107 nitrite oxidizers/g TSV. The system AF-ASB operated with HRT of 10 h demonstrated to be useful for nitrification if applied to sewage treatment with average concentration of ammonia (around 30 mg/L). It can also be pointed out that the system can be used to treat sewage with higher concentrations (over 50 mg/L) / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
172

O uso de particulas polimericas para adesão microbiana em tratamento biologico de residuos

Bergamasco, Rosangela 22 July 2018 (has links)
Orientadores: Lucia Helena Innocentini e Celia Regina Granhen Tavares / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-07-22T06:12:27Z (GMT). No. of bitstreams: 1 Bergamasco_Rosangela_D.pdf: 3909887 bytes, checksum: 9422e340b8a6dee867d7436312fef4a4 (MD5) Previous issue date: 1996 / Resumo: A utilização de particulas poliméricas para a adesão microbiana, para tratamento aeróbio de efluente sintético, foi avaliada em um reator de leito fluidizado trifásico (1 Litro). Três suportes poliméricos: polistireno, PVC e PVC + DOP ¿Plastilicizer¿ com diâmetros médios de 2,33; 2,36 e 4,68 mm e densidade de 1140, 1297 e 1205 kg/¿m POT 3¿, respectivamente, foram estudados no processo de tratamento aeróbio. Esses suportes passaram por um tratamento ácido, de modo a acrescentar-lhes características superficiais como: rugosidade, porosidade e carga elétrica, com a perspectiva de melhorar a adesão microbiana e a performance do processo de tratamento biológico. A infleência do tratamento superficial sobre as características dos suportes poliméricos foi avaliada pelas técnicas de microscopia acústica, calorimetria diferencial de varredura (DSC) e microscopia eletrônica de varredura. Três diferentes inóculos: lodo ativado, culturas puras de Klebsiella sp. e E. Coli, isolado do lodo ativado, foram utilizados com o objetivo de verificar a influência da cultura microbiana na performance do processo. Além dos controles e análises usuais do processo (DQO, MÊS, 'O INT. 2¿ dissolvido, pH, etc...) foram analisados os teores de proteína e polissacarídeos no biofilme aderido ao suporte e à saída do reator. Realizou-se durante os ensaios um acompanhamento do desenvolvimento e crescimento microbiano ...Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: The utilization of polymeric particles for microbial adhesion, in aerobic treatment with synthetic effluent, was evaluated in a three-phase fluidized-bed reactor (1 liter). Three polymeric supports ¿ polystirene, PVC and plasticizer PVC + DOP with respective averange diameters of 2.33, 3.36 and 4.68 mm and densities of 1,140, 1,297 and 1,205 kg/¿m POT. 3¿ ¿ were studied the process of aerobic treatment. The supports were submitted to an acid tratment to acquire surface characteristics of rugosity, porosity and electrical charge in order to improve the microbial adhesion and the performance of the biological treatment process. The influence of the surface treatments on the characteristis of the polymeric supports was evaluated by the use of acoustic scanning microcope, differential scanning calorimeter (DSC) and eletronic scanning microscope. Three different inocula: activated sludge, Klebsiella and E. Coli net cultures, isolated from the activated sludge, were utilized to verify the influence of microbial culture on the process perfomance. Besides the controls and usual analysis of the process (COD, suspended solids, dissolved 'O IND. 2¿, pH, etc.), protein and polysaccharide contents in the biofilm adhered to the support and the outlet of the were also analysed. The development and microbial were monitored during the experiments ...Note: The complete abstract is available with the full electronic digital thesis or dissertations / Doutorado / Ciencia e Tecnologia de Materiais / Doutor em Engenharia Química
173

Avaliação da utilização de redes neuronais aplicadas a processos quimicos

Gontarski, Carlos Alberto Ubirajara 12 June 2000 (has links)
Orientador: Milton Mori / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-07-27T01:35:19Z (GMT). No. of bitstreams: 1 Gontarski_CarlosAlbertoUbirajara_D.pdf: 12041276 bytes, checksum: 02648e927e60a3863909d625b07bf0b8 (MD5) Previous issue date: 2000 / Resumo: Este trabalho apresenta alguns aspectos importantes na aplicação de redes neuronais a simulação de processos químicos. As redes são utilizadas em dois processos industriais distintos, fornecendo uma forma de comparar as dificuldades e potencialidades da aplicação desta técnica. Na Ripasa S/A, uma das maiores indústrias de papel e celulose do Brasil, a classificação da matéria-prima para o processo de polpação que tem sido usada é baseada em uma das propriedades da madeira, a sua densidade básica. Na Ripasa se utiliza a. madeira de árvores do gênero Eucalyptus. O capítulo 3 apresenta uma alternativa mais rigorosa para o critério de classificação da matéria-prima do processo, levando em consideração outros dados tais como propriedades físicas, composição química da madeira e informações relativas à origem das árvores. Acredita-se que uma boa classificação deve se basear nas propriedades finais da polpa obtida, que são o rendimento depurado, o número Kappa, a viscosidade e a alcalinidade residual. A predição destas propriedades é um dos objetivos deste trabalho, desde que as suas determinações experimentais demandam custo e tempo de obtenção consideráveis. Utiliza-se uma técnica estatística para estimar os erros de amostragem e medida, para serem comparados com os erros gerados pelas redes neuronais. Redes neuronais foram treinadas a partir dos dados analisados da coleta de 165 amostras de madeira oriundas de oito regiões diferentes. No segundo estudo (capítulo 4) se apresenta uma forma de predizer as propriedades ambientais da corrente de saída da unidade de tratamento de efluentes líquidos na Rhodiaco Ltda, uma das plantas químicas mais importantes no Brasil. A indústria produz o ácido tereftálico e gera águas residuárias que necessitam ser tratadas em um sistema de lodo ativado. Redes neuronais do tipo "backpropagation" são utilizadas para predizer a eliminação do carbono orgânico total (TOC) peia unidade de tratamento, usando o algoritmo delta-bar-delta para ajustar os pesos e a função sigmoidaí como função de transferência nos neurônios. A .influência das variáveis de entrada é analisada e resultados satisfatórios são obtidos na predição de algumas situações analisadas. A principal conclusão destes trabalhos é que o uso de redes neuronais pode auxiliar a estabelecer melhores condições operacionais para processos químicos industriais. As redes neuronais se apresentam como ama possível ferramenta de auxílio a operação, de modo a predizer situações de pico, e propiciando ações preventivas que minimizam as flutuações na produção. No futuro, vários trabalhos deverão surgir para predizer as condições do efluente industrial baseados em dados de operação reais / Abstract: This work presents some important aspects when applying neural networks for chemicai process simulations. Neural networks are used in two different industrial processes providing a way of comparison of difficulties and potentialities for the application of this technique. Currently at Ripasa S/A. one of the largest paper industries in Brazil, the raw material classification for the pulp digester has been done using density as the property of the wood. At Ripasa S/A, the wood comes from trees of the genus Eucalyptus. The chapter 3 presents a more rigorous alternative for the criteria of raw material classification by taking into account other data such as physical properties, chemical composition of the wood and origin of the trees. A good classification should be based on the final properties of the process, which are yield. Kappa number, viscosity and residual alkalinity. Prediction of these properties by neural networks was one of the objectives of this work since experimental measurement is time-consuming and expensive. A statistical technique was used to estimate sampling and measurement errors. These values were compared with the errors generated by the neural network. Different back propagation networks were created to evaluate a suitable set of network parameters, such as number of nodes on the hidden layer, learning parameters and input range, among others. T'he networks were trained by data recorded from the analysis of 165 wood samples from eight different regions. The second work (chapter 4) presents a way to predict the environmental properties of the output stream from the wastewater treatment plant at Rhodiaco Ltda, one of the major chemical plants in Brazil. The industrial plant produces purified teiephtalic acid and generates wastewater that should be treated in an activated sludge system. Back-propagation neural networks are used to predict the elimination of total organic carbon (TOO m the treatment plant, using the delta-bar-delta algorithm for estimation of weights and the sigmoid function as the neuron transfer function. The influence of input variables is analyzed, and satisfactory predicted results are obtained for some situations analyzed. The main conclusion of this work is that the neural networks can be used to establish a better operating condition for industrial chemical processes. Neural networks represent a possible aid to operations in order to predict upsets and proacltvely act to minimize output fluctuations, in the future, some work will be done to predict effluent conditions based on the actual operation data set / Doutorado / Doutor em Engenharia Química
174

Pos-tratamento de esgoto : sistema sequencial de leitos cultivados (constructed wetlands) vertical e horizontal / Post-treatment of sawage : sequential system of vertical and horizontal constructed wetlands

Santos, Regina Maria Ferreira dos 13 August 2018 (has links)
Orientadores: Denis Miguel Roston, Marcelus Alexander Acorinte Valentim / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-13T08:39:55Z (GMT). No. of bitstreams: 1 Santos_ReginaMariaFerreirados_M.pdf: 5222301 bytes, checksum: 6d989174a6a53d3154acb1d4dba174b2 (MD5) Previous issue date: 2009 / Resumo: A Região Metropolitana de Campinas - RMC passa hoje por uma situação crítica devido ao comprometimento da qualidade de suas bacias hidrográficas e da forte pressão de demanda. O reúso se mostra como a alternativa mais plausível para satisfazer as demandas menos restritivas, liberando as águas de melhor qualidade para usos mais nobres, como o abastecimento doméstico. Inserida na RMC, mais precisamente na zona rural do Município de Sumaré, encontra-se a área de eventos, Estância Árvore da Vida - EAV. Esta área apresenta uma população fixa de aproximadamente 500 pessoas e uma população variável que pode chegar a até 10.000 pessoas durante os eventos realizados ao longo do ano. Esta propriedade tem como Estação de Tratamento um sistema de Lodos Ativados com disposição do efluente final em corpo d'água. Para melhoria da qualidade do efluente da ETE em funcionamento com vistas ao reúso, este trabalho teve como proposta avaliar um Sistema Sequencial de Pós-Tratamento por Leitos Cultivados (constructed wetland). O sistema piloto compreende: três leitos cultivados; dois de fluxo vertical em paralelo seguidos de um de fluxo horizontal, e na sequencia adaptou-se um canal para cloração do efluente. A desinfecção não faz parte do foco principal do trabalho, sua conotação foi de uma proposta inicial com vistas a estudos posteriores de um dispositivo simples e de baixo custo, que permita a aplicação do desinfetante sem a utilização de energia elétrica. As etapas de campo, construção, cultivo das macrófitas (Typha sp.) e avaliação do sistema, transcorreu ao longo de 11 meses. Os três leitos, construídos de fibra de vidro e possuíam a mesma área superficial, 2,75m2. Em termos operacionais, o sistema teve ótimo desempenho, não apresentou problemas de ordem hidráulica, indícios de colmatação do meio filtrante, odores ou surgimento de plantas invasoras. Os resultados obtidos ao longo da pesquisa apontaram: (i) Potencialidade do Sistema Sequencial (LCFVs seguidos de LCFH) na remoção de 74% de DQO, 88% de P, 97% de Turbidez, 93,5% de Cor, 93,85% de SST; (ii) Remoção de Nitrogênio amoniacal de 57,8% e acréscimo de nitrato de 40% nos LCFVs com maciço filtrante de 0,80m de altura (0,07m de brita 1 no topo, 0,60m de areia média no meio, 0,13m de brita1 no fundo); (iii) Indicação da ocorrencia da nitrificação no LCFH com o crescimento de 48,6% da DBO5 e 13% de nitrato; iv) Perfeita adaptação das macrófitas nos três leitos. Assim, recomenda-se a utilização de Sistema Sequencial de Leitos Cultivados (constructed wetlands) de Fluxo Vertical e Horizontal associado a lodos ativados tratando esgoto doméstico, entretanto, para o reuso do efluente, uma etapa de desinfecção criteriosa é altamente recomendável. / Abstract: The Metropolitan Region of Campinas - MRC faces nowadays a critical situation due to the damaged water quality of the hydrographical basins and its high demand. The reuse appears to be the most plausible alternative to satisfy the less restrictive demands, setting free the water of the best quality to nobler uses, like domestic supply. The area of events Estância Árvore da Vida - EAV is located in the MRC, precisely in the countryside of Sumaré City. This area has a fixed population of about 100 people and a fluctuating population that can reach the amount of 10.000 during the events in the whole year. The property has as a Treatment Station a system of Activated Mud with final effluent disposition in river. In order to improve the quality of the functioning ETE's effluent aiming the reuse, the present work looks forward to evaluating an Integrated System of Post-Treatment by Constructed Wetlands. The pilot system comprehends: three constructed wetlands, two of vertical in parallel flow followed by one of horizontal flow and an effluent's chlorination canal. The disinfection does not consist in the main focus of this work; it's connotation was of an initial proposal looking forward to later studies on a simple and low-cost device, which allows the application of the disinfectant without using electric energy. The field's steps, construction, macrófitas' cultivation Thypha sp. and the system evaluation, occurred during 11 months. The three bottom places were built of glass fiber and they had the same superficial area, 2,75m2. In operational terms, the system had a great performance; there were no hydraulics problems, no clogging of the filtering environment, smelling or rising of invaders plants. The obtained results during the research pointed: (i) Sequential System Potential (LCFVs followed by LCFH) by the removing of 74% of COD, 88% of P, 97% of Turbidity, 93,5% of Color, 93,85% of SST; (ii) Amoniacal nitrogen removing of 57,8% and 40% increasing of nitrate on the LCFVs with 0,80m of filtering material (0,07m of gravel on the top, 0,60m of tiny sand on the middle and 0,13m of gravel on the bottom); (iii) Indication of nitrification occurrence on LCFH with 48,6% growing of BOD5 and 13% of nitrate; iv) Perfect adaptation of the macrophytes on the three bottom places. Therefore it's recommended the use of the Sequential System of constructed wetlands of vertical and horizontal flow associated to activated mud treating domestic sewer, however for the effluent's reuse it's highly recommended a rigorous disinfection procedure. / Mestrado / Agua e Solo / Mestre em Engenharia Agrícola
175

Tratamento de efluentes de uma industria de reciclagem de embalagens plasticas de oleos lubrificantes : processo biologico e fisico-quimico / Treatment of industry wastewater from a plastic containers (containing originally lubricant oil) recycling industry : biological and physical-chemical process

Moreno, Francisco Navarro 19 December 2007 (has links)
Orientadores: Jose Roberto Guimarães, Carlos Gomes da Nave Mendes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-11T13:54:45Z (GMT). No. of bitstreams: 1 Moreno_FranciscoNavarro_M.pdf: 4932660 bytes, checksum: fcd2b44ce7307660ce7b34dec37ecae0 (MD5) Previous issue date: 2007 / Resumo: A proposta deste trabalho foi avaliar o desempenho individual do processo de lodos ativados por batelada (LAB) e da flotação por ar dissolvido (FAD) para tratar águas residuárias de uma indústria de reciclagem de embalagens plásticas com resíduo de óleo lubrificante, compostas pela água de lavagem dos frascos plásticos misturadas com esgoto sanitário. Para a realização da fase experimental do sistema LAB foram montados quatro reatores aerados operando em mistura completa, nos quais foi testada a influência da idade do lodo, assim como da biomassa de partida. Os sistemas operados com aeração prolongada foram os que apresentaram melhor eficiência para reduzir a DQO, a DBO5 e a turbidez, atingindo uns valores máximos de remoção iguais ao 92,9, 97,1, 98,8 %, respectivamente. Os resultados obtidos demonstraram que a utilização de uma biomassa de partida adaptada a tratar efluentes oleosos permitiu uma melhor eficiência de remoção dos óleos, variando entre 88,3 e 91,3 %. Para avaliar o segundo método em estudo, o FAD, foram realizados testes em escala de bancada utilizando aparelho floteste. Dois coagulantes químicos foram testados inicialmente, variando os valores de pH e dosagem. Com aquele que apresentou melhores resultados foi construído o diagrama de coagulação a fim de averiguar as regiões mais eficientes de trabalho. O ponto ótimo resultou em reduções nos valores de DQO, DBO5, O&G e turbidez de 90,2, 80,1, 99,0 e 99,6 %, respectivamente. Os dois sistemas de tratamento estudados demonstraram uma grande potencialidade de uso para tratar o tipo de efluente em estudo, porém, o sistema FAD revelou-se como a tecnologia mais adequada para tratar o efluente líquido gerado numa indústria de reciclagem de embalagens plásticas pós-uso de óleos lubrificantes / Abstract: In the present work, the treatment of the wastewater originated in a plastic container (containing originally lubricant oil) recycling industry was investigated. The purpose of this work was to study the individual efficiency to treat the industrial effluent, mixture of the plastic container washing process wastewater and sanitary wastewater, by activated sludge process operating in sequencing batch reactors (SBR) and dissolved air flotation (DAF). The experiments for the SBR processes were performed in four completely mixed aerated reactors, which were used to test the influence of the sludge age and the original biomass. The extended aeration system showed the best efficiency in the reduction of the main pollutants, with a removal of DQO, DBO5 and turbidity equal to 92.9, 97.1 and 98.8 % respectively. Oil reduction using a original biomass adapted to treat oil effluents was more effective (oil reduction of 88.3 and 99.1 %). To evaluate the second process, DAF, it was used a batch type lab-scale dissolved air flotation installation (floteste). Initially, two different coagulants were tested, in different pH values of effluent and coagulant doses. With the most efficient coagulant it was built the coagulation diagram. Under the optimal conditions, DAF system obtained a removal efficiency of DQO, DBO5, O&G and turbidity of 90.2, 80.1, 99.0 and 99.6 % respectively. It is concluded that the activated sludge process and DAF are technologies with a high potential to treat the liquid effluent originated in a plastic bottles containing originally lubricant oil recycling industry, notwithstanding DAF system was the most adequate methods / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
176

Eficiencia da filtração lenta no tratamento de efluentes de leitos cultivados

Londe, Luciana de Resende 01 August 2018 (has links)
Orientador : Jose Euclides Stipp Paterniani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-01T12:55:51Z (GMT). No. of bitstreams: 1 Londe_LucianadeResende_M.pdf: 1900414 bytes, checksum: 60c1453fbd04def6155080be8275d1f1 (MD5) Previous issue date: 2002 / Mestrado
177

Reator compartimentado anaerobio/aerobio, tratando esgoto sanitario : desempenho e operação / Anaerobic/aerobic Baffled Reactor Treating Sanitary Wastewater: Performance and Operation

Silva, Gustavo Henrique Ribeiro da 21 December 2001 (has links)
Orientador: Edson Aparecido Abdul Nour / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T00:31:08Z (GMT). No. of bitstreams: 1 Silva_GustavoHenriqueRibeiroda_M.pdf: 10901410 bytes, checksum: 214e9f14f9626400264bad3cf93fade5 (MD5) Previous issue date: 2001 / Resumo: No presente trabalho de pesquisa foi estudada uma alternativa de união de processos anaeróbios e aeróbios sob a forma de um reator compartimentado anaeróbio/aeróbio, no tratamento de esgoto sanitário. O reator era composto por quatro câmaras seqüenciais, sendo as três primeiras anaeróbias e a última aeróbia, totalizando um volume aproximado de 2,5 m3. O Iodo gerado pelo reator foi separado em um decantador laminar e recirculado à quarta câmara. O reator, localizado em uma E.T.E. da cidade de Limeira, SP, foi operado durante um período de 444 dias, divido em cinco fases, com tempo de detenção hidráulica (TDH) total variando de 7 a 16 horas, alimentado com esgoto sanitário que havia recebido tratamento preliminar. As cinco fases de operação corresponderam a 10, 16, 12, 8 e 7 horas de TDH. Os valores de pH ao longo de todas as câmaras e decantador, variaram entre 5,7 e 8,3 e o valor médio foi de 6,8, não sendo necessário correção e pH durante o período de estudo. Os melhores valores de remoção de 0805 foram obtidos na Fase 4 (TDH=8 horas), 56,9 a 95,7%. Contudo o teste estatístico de comparação de médias de duas amostras, verificou não. haver diferença significativa entre as fases, exceto Fase 2, ao nível de P=O,05. O desempenho do reator quanto a remoção de DQOtotal e SST foi semelhante ao obtido para 0805, com valores de 31,4 a 95,6 e 21,0 a 97,3%, respectivamente, o mesmo ocorrendo para o teste estatístico realizado. Os valores encontrados para oxigênio dissolvido no interior da câmara 4 (aeróbia) foram satisfatórios na maior parte do tempo, de acordo com os valores citados na literatura, alcançando valor máximo de 4,70 e mínimo de O mg 02.L-1. A presença do decantador laminar foi importante na remoção de sólidos provenientes do reator. Após o 1070 dia de operação, o Iodo de recirculação apresentou uma sedimentabilidade de boa a ótima. A configuração do sistema em estudo, promove adequado tratamento do efluente aplicado aliado a uma produção de Iodo aeróbio de fácil gerenciamento / Abstract: The present research aimed to study an alternative route for union of aerobic and anaerobic processes, through the use of a baffled reactor, treating sanitary wastewater. The reactor is composed of four sequential chambers, being the first tree anaerobic chambers and the last one aerobic, composing a total volume of approximately 2.5 m3. The sludge generated in the reactor is separated in a laminar sedimentation tank and recycled into the forth chamber. The reactor - placed in a wastewater treating plan of Limeira city, S. P., 8razil -operated in a period of 444 days. This period was divided in five phases, with hydraulic detention times (HOT) varying from 7 to 16 hours. The reactor was fed with sanitary wastewater which had already suffered a preliminary treatment. The five phases of operation corresponded to 10, 16, 12,8 e 7 hours of HOT, respectively. The pH values in all chambers and in the sedimentation tank, varied between 5,7 e 8,3, with a mean value of 6,8; the correction of pH values was not necessary during all periods. The best value of 8005 removal was attained in the Phase 4 (HOT=8 hours), 56,9 to 95,7%. However, the statistic comparison of the means .of two samples showed that there was no significant difference between the phases, except in Phase 2, with P=0,05. The reactor performance, in relation to COOtotal removal and TSS, was similar to that obtained for the 8005, with values of 31,4 to 95,6 and 21,0 to 97,3%, respectively. The same occurred in the statistic test. In chamber 4, the oxygen dissolved values were satisfactory in most of the periods, reaching the maximum of 4,7 and of 0,0 mg 02.L-1. The laminar sedimentation tank was important for removal of solids produced in the sedimentation tank. After the 10ih operation day, the recycled sludge presented a sedimentation capability classified between good and very good. Thus, It is possible to affirm that the baffled reactor configuration of the present work promotes an useful effluent treatment, employed to the production of an aerobic sludge with easy management / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
178

A situação brasileira dos biossolidos

Machado, Maria Fernanda de Sousa 13 July 2001 (has links)
Orientador : Roberto Feijo de Figueiredo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T03:55:24Z (GMT). No. of bitstreams: 1 Machado_MariaFernandadeSousa_M.pdf: 10713217 bytes, checksum: 6261d27597e776e395189569e356f882 (MD5) Previous issue date: 2001 / Resumo: Os processos de tratamento de esgoto geram diversos subprodutos, dentre eles o lodo, que é responsável por um elevado custo operacional em seu tratamento, transporte e disposição final. Biossólidos é um novo termo designado para o lodo estabilizado, gerado nas estações de tratamento de esgoto que possa ser recic1ado, recebendo assim um destino final mais útil, como por exemplo a aplicação no solo para fins agrícolas. Visando estas novas potencialidades do lodo de esgoto, este estudo apresenta um diagnóstico da situação brasileira dos biossólidos, abordando a sua produção real e teórica, o destino final e a sua constituição, além de informações referentes ao tratamento de esgoto no Brasil. A metodologia desta pesquisa consistiu na elaboração de um formulário enviado às prestadoras de serviços de saneamento responsáveis pelas estações de tratamento de esgoto, com questões relacionadas ao lodo e ao tratamento de esgoto. Foram coletados os dados provenientes de 275 estações, que são responsáveis pelo tratamento de 1.877.618,25 m3/dia de esgoto, atendendo a 12.777.974 pessoas, e produzindo teoricamente 151.724,50 toneladas/ano de lodo seco. As informações referentes à produção real e à constituição dos biossólidos são bastante escassas, pois, a maioria das operadoras de tratamento de esgoto não produzem as informações referentes ao lodo de forma sistemática, dando enfoque somente ao esgoto tratado, o que revela a necessidade urgente de investimentos nesse setor / Abstract: The wastewater treatment process generate several subproducts, one of them is the sewage sludge, which has a higher operational cost of treatment, transportation and final disposal.Biosolids is a new word assigned to the stabilized sludge generated in the wastewater treatment plants, in order to be recyc1ed, having a more useful final disposal, such as applying to agricultural land. Visualizing these new potential uses of sewage sludge, this study presents a diagnostic of the Brazilian situation of biossolids, approaching its real and theoretical production, final disposal and constituents, as well as information related to wastewater treatment in Brazil. The methodology used in this research consisted on the elaboration of a questionaire sent to the companies suppliers of sanitation services which are responsible for wastewater treatment plants, with questions related to sludge and sewage treatment. There was collected data answered by 275 wastewater treatment plants, which are responsible for the treatment of 1,877,618,25 m3/day of wastewater, providing this service to 12,777,974 inhabitants and producing theoretically 151,724.50 tons/year of dried sludge. The information regarding the real production and constitution of the biosolids are very scant, because most of the wastewater treatment companies do not report enough information regarding the sludge in a systematic manner, reporting only data about the treated sludge, disc1osing a urgent need of investments in this sector / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
179

Estudo do tratamento de aguas residuarias por lodo ativado em reator "air-lift" de tubos concentricos / Study of treatment of waste water by activated sludge in the reactor "air-lift" of concentric tubes

Alberte, Tania Maria 13 March 2003 (has links)
Orientador : Ranulfo Monte Alegre / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-03T14:22:54Z (GMT). No. of bitstreams: 1 Alberte_TaniaMaria_D.pdf: 9835439 bytes, checksum: 74ab1a7efc7d568bc9c3b37f762f08ec (MD5) Previous issue date: 2003 / Resumo: Reatores "air-lift" são uma classe especial de coluna de bolhas, sendo recentemente utilizados em processos químicos, bioquímicos e em tratamento de águas residuárias. Neste trabalho, estudou-se o desempenho de um reator "air-lift" de tubos concêntricos no tratamento de água residuária sintética utilizando Iodo ativado. O reator construido de aço-inox, com tubos de aeração e reciclo de 1,2 e 1,5 m respectivamente, foi alimentado com água residuária sintética, sendo o Iodo separado em sedimentador na parte superior do reator e reciclado ao mesmo. A pressão manométrica no reator variou de O a 1,2 Kgf.cm-2, vazão de ar de 200 a 1600 mL.min-1 e vazão de substrato de 200 a 400 mL.h-1. Para cada taxa de alimentação, vazão de ar e pressão, o reator foi operado de forma contínua até que o estado estacionário hidráulico e microbiológico fossem atingidos. As amostras foram retiradas na altura média do reator e análises da Demanda Química de Oxigênio (DQO) e biomassa (quantificada como sólidos suspensos voláteis - SSV) foram feitas de acordo com métodos descritos pelo "Standard Methods for the Examination of Water and Wastewater" (1985). Os três parâmetros, vazão de alimentação, vazão de ar e pressão, variaram gradativamente, além da concentração de DQO do substrato (1100 a 8600 mgDQO.L-1), de forma que foi possível aumentar a concentração de Iodo no reator (SSV) de 1010 a 15000 mgSSV.L-1, sendo este último valor cerca de cinco vezes maior que os de processos convencionais de Iodo ativado, que é de 2000 a 3000 mgSSV.L -1 (Ramalho, 1983). Isto permitiu aumentar a eficiência de redução de DQO de 47 a 87%, respectivamente para reator operado a pressão ambiente e com variação de pressão. O coeficiente de transferência de oxigênio (K1a) aumentou com o aumento da vazão de ar até o limite de 1000 mL.min-1 (5,41 h-1), decrescendo para vazões superiores a esta, possivelmente devido à coalescência de bolhas. O coeficiente de retenção de gás (Eg) foi determinado e, para as vazões de ar testadas (200 a 1400 mL.min-1), variou de 2,08.10-3 a 12,95.10-3, proporcionalmente às vazões de ar utilizadas / Abstract: Air lift reaetors are a speeial elass of bubble eolumns and are been reeently used in ehemieal and bioehemical processes, as well as in wastewater treatment. In this work, it was studied the performanee of aeoneentrie tube air lift reaetor in the synthetie wastewater treatment by aetivated sludge. The reaetor was eonstrueted of stainless steel, 1.2 m high of riser and 1.5 m high of downeomer. It was fed with synthetie wastewater and the sludge was separeted in a sedimentator in the top of reaetor and reeyeled. The manometrie pressure varied from O to 1.2 kgf.em'2, the air flow rate from 200 to 1,600 mL.min-1 and the feed solution from 200 to 400 mL.h -1. To eaeh feed solution of synthetie wastewater rate, air flow rate and pressure, the reaetor was operated in eontinuous form until the hidraulie and mierobiologieal steady-state was reaehed. The samples were eolleeted in the half of the reaetor. Chemieal oxygen demand (COO) and volatils solids eoneentration (VSS) was determinated aceording to ín Standard Methods for the Examínation of Water and Wastewater (1985). Feed solution rate, air flow rate and pressure rangedgradually, as well as eoneentration of feed synthetie wastewater (1,100 of 8,600 mgCOO.L- / Doutorado / Doutor em Engenharia de Alimentos
180

Tratamento de efluente textil e lodo gerado em um sistema de lodos ativados por batelada com adição de carvão ativado em po

Chavez Porras, Alvaro 28 November 2002 (has links)
Orientador : Ricardo de Lima Isaac / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T22:21:11Z (GMT). No. of bitstreams: 1 ChavezPorras_Alvaro_M.pdf: 6504714 bytes, checksum: 6cd17d1578c8e4907ddf123e9bee21c9 (MD5) Previous issue date: 2002 / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil

Page generated in 0.2772 seconds