Spelling suggestions: "subject:"águas residual - purificação"" "subject:"aguas residual - purificação""
211 |
Remoção da amônia por air stripping em canais corrugados helicoidais / Removal of ammonia by air stripping in helicoidais corrugated channelsDelduque, Thalita Pereira 23 February 2017 (has links)
CNPQ / O presente trabalho propõe verificar o desempenho de um canal corrugado helicoidal aplicado na remoção de amônia, por meio do processo air stripping. O sist p ssui iâ tr i t r 4’’(≈100 m) e 10m de comprimento disposto de forma helicoidal. Avaliou-se a influência das condições operacionais como: vazão de ar (1000 L min-1 a 3000 L min-1), vazão do líquido (0,2 L min-1 a 1,0 L min-1), concentração de nitrogênio, pH (9,0 a 12,0) e declividade do canal (5% a 20%) na remoção da amônia. Foram realizados ensaios de caracterização hidrodinâmica do sistema com ajuste dos modelos uni-paramétricos: de N-reatores de mistura completa em série, dispersão de grande intensidade e pequena intensidade, visando a determinação dos coeficientes globais de transferência de massa (KLa). Entre os principais resultados, a massa de alcalinizante necessária para elevar o pH em média de 5 para 11,5, foi de 2,875g de NaOH por g de N presente na água residuária. Posteriormente, ensaios hidrodinâmicos indicaram que o escoamento do sistema tende a ser pistonado em função do seu alto número de reatores de mistura completa em série (49 a 69). Foram realizados 30 ensaios utilizando o planejamento estatístico, Delineamento Composto Central Rotacional (DCCR) com coeficiente de transferência de massa (KLa) de 19,7h-1 nas condições otimizadas de pH 10,5, Qar=2000 L min-1, Qliq=0,2 L min-1 na concentração de 0,6 mgL-1 N-NH3 atingindo a eficiência de remoção de N-NH3 de 70%. Com os valores experimentais foi possível obter o modelo reparametrizado das variáveis codificadas, que representa a remoção de N-NH3(%) em função do pH, da vazão de ar, da vazão do líquido e da concentração de N-NH3. Ao se comparar com torres convencionais de air stripping, o canal corrugado proporcionou maior tempo de contato ar com o líquido, para injeção do ar e menor altura manométrica de elevação da água residuária, reduzindo gastos construtivos e com energia elétrica. / The present work intent to verify the performance of a helical corrugated channel applied in the ammonia removal, through the air stripping process.The syst h s i t r l i t r 4 "(≈100 mm) and 10m long, helically arranged. The influence of the operating conditions was evaluated as: air flow (1000 Lmin-1 at 3000 L min-1), liquid flow (0.2 L min-1 at 1.0 L min-1), nitrogen concentration, pH (9.0 to 12.0) and channel slope (5% to 20%) in the ammonia removal. It was performed hydrodynamic characterization of the system with adjustment of the uni-parametric models: complete mix N-reactors in series, big intensity and small intensity dispersal, aiming the determination of the global coefficients of mass transfer (KLa). Among the main results, the alkaline mass required to raise the pH from 5 to 11.5 on average was 2.875 g of NaOH per g of N present in the wastewater. Subsequently, hydrodynamic tests indicated that the drain of the system tends to be pistoned due to its high number of compete mix reactors in grade (49 to 69). A total of 30 experiments were performed using the statistic design, Design Central Composit Rotational (DCCR) with mass transfer coefficient (KLa) of 19.7h-1 under optimized conditions of pH 10.5, Qar=2000 L min-1, Qliq=0.2 L min-1 in the concentration of 0.6 mgL-1 N-NH3 achieving the efficiency of removal of N-NH3 of 70%. With the experimental values it was possible to obtain the reparametrized model of the coded variables, which represents the removal of N-NH3 (%) as a function of pH, air flow, liquid flow and N-NH3 concentration. When compared to conventional air stripping towers, the corrugated channel provided longer air-to-liquid contact time for air injection and lower manometric height of wastewater elevation, reducing constructive and electricity expenditures.
|
212 |
Associação de sistema biológico do tipo lodo ativado com reatores air lift e fotocatálise heterogênea com TiO2 para a remediação de efluente oriundo da produção industrial de TNT / Association of organic system sludge type with reactors air lift and photocatalysis heterogeneous with TiO2 for remedy of waste arising out of industrial production TNTGuz, Ricardo 28 March 2016 (has links)
Na etapa de purificação do trinitrotolueno (TNT) produzido nas indústrias, são realizadas duas lavagens ao final do processo. A primeira lavagem é realizada com água vaporizada, na qual origina-se o primeiro efluente, denominado água amarela, em seguida, é realizada uma segunda lavagem com a utilização de sulfito de sódio (Na2SO3), gerando o segundo efluente água vermelha. O presente trabalho teve como objetivo estudar os efeitos individuais, bem como, a associação da fotocatálise heterogênea utilizando TiO2 e tratamento biológico em reator air lift utilizando lodo ativado (biomassa bacteriana), para a remediação de águas residuais contaminadas com compostos nitroaromáticos, a fim de reduzir a toxicidade e ajustar os parâmetros legais de acordo com órgãos regulamentadores para despejo em vias aquáticas. O tratamento fotocatalítico foi conduzido por meio de desenho fatorial obtendo as melhores condições reacionais (pH 6,5 e concentração de TiO2 0,1 gL-1), sendo os melhores resultados obtidos em 360 minutos de reação, reduzindo 97,00% da absorbância em 275 nm, 94,20% da demanda química de oxigênio (DQO), 67,70% de fenóis totais, bem como uma redução total dos picos constatados e atribuídos a compostos nitroaromáticos por cromatografia líquida de alta eficiência. No tratamento biológico, observou-se redução de 53,40% da absorbância em 275 nm, 10,00% de DQO e 36,00% de fenóis totais em períodos curtos (3 dias), já para períodos longos (48 dias), houve uma influência antagônica nos resultados de forma que ocorreu a elevação destes parâmetros (DQO e fenóis totais) ao invés de sua redução. A análise cromatográfica confirmou a eficiência da degradação biológica por meio da redução de picos correspondentes a compostos como DNT e TNT. A associação dos tratamentos fotocatalítico e biológico apresentou resultados de redução da ordem de 91,10% de absorbância, 70,26% de fenóis totais e 88,87% de DQO. Enquanto que, a associação dos tratamentos biológico e fotocatalítico gerou eficiências relativamente inferiores, apresentando redução de absorbância de 77,30%, 62,10% de redução dos fenóis totais e uma diminuição de 87,00% da DQO. De maneira geral, ao compararmos os processos químico e biológico de forma isolada, o tratamento fotocatalítico apresentou os melhores resultados. Porém, comparando os resultados de forma isolada e as associações estabelecidas, a associação biológico x fotocatalise apresentou resultados mais promissores para o tratamento do efluente água vermelha. / Trinitrotoluene in the purification step (TNT) produced in industries, are carried out two washes at the end of the process. The first wash is done with vaporized water, which originates from the first effluent called yellow water, then the second washing with the use of sodium sulfite is performed (Na2SO3), generating a second effluent red water. This study aimed to study the individual effects, as well as the association of heterogeneous photocatalysis using TiO2 and biological treatment in air lift reactor using activated sludge (bacterial biomass) for the remediation of wastewater contaminated with nitroaromatic compounds in order to reduce toxicity and adjust the legal parameters according to regulatory agencies for disposal in waterways. The photocatalytic treatment was conducted by factorial design obtaining the best reaction conditions (pH 6.5 and concentration of TiO2 0.1 gL-1), with best results obtained at 360 minutes of reaction, reducing the absorbance 97.00%, 94.20% of the chemical oxygen demand (COD), 67.70% of total phenols, as well as a total reduction of observed peaks and assigned to nitroaromatic compounds by high-performance liquid chromatography. In the biological treatment, there was a 53.40% reduction in absorbance at 275 nm 10.00% 36.00% COD and total phenols in a short time (3 days), while for extended periods (48 days) there was an antagonistic influence on the results so that was the elevation of these parameters (COD and total phenols) instead of reducing. Chromatographic analysis confirmed the effectiveness of the biological degradation by reducing the peaks corresponding to compounds DNT and TNT. The Association of photocatalytic and biological treatments decreased results in the order of 91.10% absorbance, 70.26% of total phenols and 88.87% of COD. While the combination of biological and photocatalytic treatments generated relatively lower efficiencies, with 77.30% of absorbance reduction, 62.10% reduction of total phenols and a decrease of 87.00% of COD. In general, when comparing the chemical and biological processes in isolation, the photocatalytic treatment showed the best results. However, comparing the results of isolation and established associations, the association biological x photocatalysis showed more promising results in the treatment of red water effluent.
|
213 |
Remoção da amônia por air stripping em canais corrugados helicoidais / Removal of ammonia by air stripping in helicoidais corrugated channelsDelduque, Thalita Pereira 23 February 2017 (has links)
CNPQ / O presente trabalho propõe verificar o desempenho de um canal corrugado helicoidal aplicado na remoção de amônia, por meio do processo air stripping. O sist p ssui iâ tr i t r 4’’(≈100 m) e 10m de comprimento disposto de forma helicoidal. Avaliou-se a influência das condições operacionais como: vazão de ar (1000 L min-1 a 3000 L min-1), vazão do líquido (0,2 L min-1 a 1,0 L min-1), concentração de nitrogênio, pH (9,0 a 12,0) e declividade do canal (5% a 20%) na remoção da amônia. Foram realizados ensaios de caracterização hidrodinâmica do sistema com ajuste dos modelos uni-paramétricos: de N-reatores de mistura completa em série, dispersão de grande intensidade e pequena intensidade, visando a determinação dos coeficientes globais de transferência de massa (KLa). Entre os principais resultados, a massa de alcalinizante necessária para elevar o pH em média de 5 para 11,5, foi de 2,875g de NaOH por g de N presente na água residuária. Posteriormente, ensaios hidrodinâmicos indicaram que o escoamento do sistema tende a ser pistonado em função do seu alto número de reatores de mistura completa em série (49 a 69). Foram realizados 30 ensaios utilizando o planejamento estatístico, Delineamento Composto Central Rotacional (DCCR) com coeficiente de transferência de massa (KLa) de 19,7h-1 nas condições otimizadas de pH 10,5, Qar=2000 L min-1, Qliq=0,2 L min-1 na concentração de 0,6 mgL-1 N-NH3 atingindo a eficiência de remoção de N-NH3 de 70%. Com os valores experimentais foi possível obter o modelo reparametrizado das variáveis codificadas, que representa a remoção de N-NH3(%) em função do pH, da vazão de ar, da vazão do líquido e da concentração de N-NH3. Ao se comparar com torres convencionais de air stripping, o canal corrugado proporcionou maior tempo de contato ar com o líquido, para injeção do ar e menor altura manométrica de elevação da água residuária, reduzindo gastos construtivos e com energia elétrica. / The present work intent to verify the performance of a helical corrugated channel applied in the ammonia removal, through the air stripping process.The syst h s i t r l i t r 4 "(≈100 mm) and 10m long, helically arranged. The influence of the operating conditions was evaluated as: air flow (1000 Lmin-1 at 3000 L min-1), liquid flow (0.2 L min-1 at 1.0 L min-1), nitrogen concentration, pH (9.0 to 12.0) and channel slope (5% to 20%) in the ammonia removal. It was performed hydrodynamic characterization of the system with adjustment of the uni-parametric models: complete mix N-reactors in series, big intensity and small intensity dispersal, aiming the determination of the global coefficients of mass transfer (KLa). Among the main results, the alkaline mass required to raise the pH from 5 to 11.5 on average was 2.875 g of NaOH per g of N present in the wastewater. Subsequently, hydrodynamic tests indicated that the drain of the system tends to be pistoned due to its high number of compete mix reactors in grade (49 to 69). A total of 30 experiments were performed using the statistic design, Design Central Composit Rotational (DCCR) with mass transfer coefficient (KLa) of 19.7h-1 under optimized conditions of pH 10.5, Qar=2000 L min-1, Qliq=0.2 L min-1 in the concentration of 0.6 mgL-1 N-NH3 achieving the efficiency of removal of N-NH3 of 70%. With the experimental values it was possible to obtain the reparametrized model of the coded variables, which represents the removal of N-NH3 (%) as a function of pH, air flow, liquid flow and N-NH3 concentration. When compared to conventional air stripping towers, the corrugated channel provided longer air-to-liquid contact time for air injection and lower manometric height of wastewater elevation, reducing constructive and electricity expenditures.
|
214 |
Associação de sistema biológico do tipo lodo ativado com reatores air lift e fotocatálise heterogênea com TiO2 para a remediação de efluente oriundo da produção industrial de TNT / Association of organic system sludge type with reactors air lift and photocatalysis heterogeneous with TiO2 for remedy of waste arising out of industrial production TNTGuz, Ricardo 28 March 2016 (has links)
Na etapa de purificação do trinitrotolueno (TNT) produzido nas indústrias, são realizadas duas lavagens ao final do processo. A primeira lavagem é realizada com água vaporizada, na qual origina-se o primeiro efluente, denominado água amarela, em seguida, é realizada uma segunda lavagem com a utilização de sulfito de sódio (Na2SO3), gerando o segundo efluente água vermelha. O presente trabalho teve como objetivo estudar os efeitos individuais, bem como, a associação da fotocatálise heterogênea utilizando TiO2 e tratamento biológico em reator air lift utilizando lodo ativado (biomassa bacteriana), para a remediação de águas residuais contaminadas com compostos nitroaromáticos, a fim de reduzir a toxicidade e ajustar os parâmetros legais de acordo com órgãos regulamentadores para despejo em vias aquáticas. O tratamento fotocatalítico foi conduzido por meio de desenho fatorial obtendo as melhores condições reacionais (pH 6,5 e concentração de TiO2 0,1 gL-1), sendo os melhores resultados obtidos em 360 minutos de reação, reduzindo 97,00% da absorbância em 275 nm, 94,20% da demanda química de oxigênio (DQO), 67,70% de fenóis totais, bem como uma redução total dos picos constatados e atribuídos a compostos nitroaromáticos por cromatografia líquida de alta eficiência. No tratamento biológico, observou-se redução de 53,40% da absorbância em 275 nm, 10,00% de DQO e 36,00% de fenóis totais em períodos curtos (3 dias), já para períodos longos (48 dias), houve uma influência antagônica nos resultados de forma que ocorreu a elevação destes parâmetros (DQO e fenóis totais) ao invés de sua redução. A análise cromatográfica confirmou a eficiência da degradação biológica por meio da redução de picos correspondentes a compostos como DNT e TNT. A associação dos tratamentos fotocatalítico e biológico apresentou resultados de redução da ordem de 91,10% de absorbância, 70,26% de fenóis totais e 88,87% de DQO. Enquanto que, a associação dos tratamentos biológico e fotocatalítico gerou eficiências relativamente inferiores, apresentando redução de absorbância de 77,30%, 62,10% de redução dos fenóis totais e uma diminuição de 87,00% da DQO. De maneira geral, ao compararmos os processos químico e biológico de forma isolada, o tratamento fotocatalítico apresentou os melhores resultados. Porém, comparando os resultados de forma isolada e as associações estabelecidas, a associação biológico x fotocatalise apresentou resultados mais promissores para o tratamento do efluente água vermelha. / Trinitrotoluene in the purification step (TNT) produced in industries, are carried out two washes at the end of the process. The first wash is done with vaporized water, which originates from the first effluent called yellow water, then the second washing with the use of sodium sulfite is performed (Na2SO3), generating a second effluent red water. This study aimed to study the individual effects, as well as the association of heterogeneous photocatalysis using TiO2 and biological treatment in air lift reactor using activated sludge (bacterial biomass) for the remediation of wastewater contaminated with nitroaromatic compounds in order to reduce toxicity and adjust the legal parameters according to regulatory agencies for disposal in waterways. The photocatalytic treatment was conducted by factorial design obtaining the best reaction conditions (pH 6.5 and concentration of TiO2 0.1 gL-1), with best results obtained at 360 minutes of reaction, reducing the absorbance 97.00%, 94.20% of the chemical oxygen demand (COD), 67.70% of total phenols, as well as a total reduction of observed peaks and assigned to nitroaromatic compounds by high-performance liquid chromatography. In the biological treatment, there was a 53.40% reduction in absorbance at 275 nm 10.00% 36.00% COD and total phenols in a short time (3 days), while for extended periods (48 days) there was an antagonistic influence on the results so that was the elevation of these parameters (COD and total phenols) instead of reducing. Chromatographic analysis confirmed the effectiveness of the biological degradation by reducing the peaks corresponding to compounds DNT and TNT. The Association of photocatalytic and biological treatments decreased results in the order of 91.10% absorbance, 70.26% of total phenols and 88.87% of COD. While the combination of biological and photocatalytic treatments generated relatively lower efficiencies, with 77.30% of absorbance reduction, 62.10% reduction of total phenols and a decrease of 87.00% of COD. In general, when comparing the chemical and biological processes in isolation, the photocatalytic treatment showed the best results. However, comparing the results of isolation and established associations, the association biological x photocatalysis showed more promising results in the treatment of red water effluent.
|
215 |
Utilização de reator aeróbio de leito fluidizado com circulação em tubos concêntricos no tratamento de águas residuarias da produção intensiva de tilapia com recirculação da água tratadaMaigual Enriquez, Yemall Alexander [UNESP] 22 August 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:23Z (GMT). No. of bitstreams: 0
Previous issue date: 2011-08-22Bitstream added on 2014-06-13T20:20:51Z : No. of bitstreams: 1
maigualenriquez_ya_me_ilha.pdf: 1515184 bytes, checksum: 854b45266358b64c6017c5058af88c81 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Sistemas de Recirculação para Aquicultura (SRA) possibilitam um meio alternativo de produção de peixes para áreas com limitada disponibilidade de água. Estes sistemas de cultivo intensivo de peixes oferecem potencial de produção em pequena escala assim como em grande escala, devido a recuperação de efluentes e a reutilização da água, produzindo volumes relativamente pequenos de resíduos líquidos e sólidos. O objetivo deste estudo foi determinar a eficácia do tratamento de águas residuárias em relação à remoção de Nitrogênio Amoniacal Total (NAT), Sólidos Totais (ST), Sólidos Suspensos Totais (SST), Demanda Química de Oxigênio (DQO) e Demanda Bioquímica de Oxigênio (DBO5), Nitrogênio total (NT) e Fósforo Total (FT). Para tanto, foram introduzidos Tilápia do Nilo (Oreochromis niloticus), com 0,323kg de peso médio inicial e 17 kg m-3 de densidade de armazenamento inicial no SRA experimental. O SRA era composto de 03 tanques de plástico com capacidade de 0,20 m3, Decantador de Coluna (DC), o reator de leito fluidizado aeróbio com circulação em tubos concêntricos (BAS-CT), tendo como meio de suporte a areia de diâmetro efetivo (D10) = 0,29 mm e na sequência reator de transferência de oxigênio e remoção de CO2. A eficiência na remoção do NAT no reator BAS-CT no período de aclimatação e de estabilização foi 31,0% e 35,2%, respectivamente. A remoção de ST e SST foi de 44,44% e 71,71%, respectivamente. A eficiência alcançada de remoção no SRA da DQO foi de 64,90% e de 48,01% para DBO5. Os valores médios de remoção do NT e FT no SRA foram de 25,02% e 41,05%, respectivamente. Estes resultados indicaram que o tratamento de águas residuárias de aquicultura proposto neste estudo através do BAS-CT associado ao DC tem evitado elevadas concentrações e acumulação de poluentes dentro do SRA / Recirculating aquaculture systems (RAS) offer an alternative means of fish production for areas that to have limited water and land availability. RAS are a highly intensive fish culture systems and offer potential production units for small and large scale operations. For effluent recovery and treated water reuse, RAS produce relatively small volumes of liquid and solids wastes. The objective of this study were to determine the efficiency of the wastewater treatment with recommended to removal of Total Ammonia Nitrogen (TAN), Total Solids (TS), Total Suspended Solids (TSS), Chemical Oxygen Demand (COD) and Biochemical Oxygen Demand (BOD5), Total Nitrogen (TN) and Total Phosphorus (TP). In this study was cultivating the Nile Tilapia (Oreochromis niloticus) with 0.323kg initial average weight and 17 kg m-3 initial storage density, cultivated in RAS. The RAS was composed with 03 plastic tanks with capacity of 0.20 m3 in each, column settler (CS), aerobic fluidized bed reactor with concentric tubes circulation (BAS-CT) with sand bed support of effective diameter (D10) of 0.29 mm and oxygen transfer-CO2 removal reactor. NAT removal efficiency was in acclimation and stabilized periods in BAS-CT reactor were 31.0% and 35.2% respectively. TS and TSS removal was 44.44% and 71.71% respectively. In this RAS, the COD removal efficiency reached was 64.90% and 48.01% for BOD5. The average removal in the NT and FT in the RAS were 25.02% and 41.05% respectively. These results indicate that aquaculture wastewater treatment proposed in this study by BAS-CT associated to CS prevents high concentrations and accumulating of pollutants within the SRA
|
216 |
Preparação, caracterização e aplicação de híbridos de montmorilonita-alginato-nanopratas na desinfecção de efluentes industriais para águas de reusoLovatel, Rosa Helena 24 September 2014 (has links)
Diferentes técnicas têm sido desenvolvidas para eliminar micro-organismos de efluentes industriais e melhorar a sua qualidade final. Dentre elas, o uso de nanopartículas de prata (AgNPs) ancoradas em montmorilonita (MMT) tem demonstrado bons resultados. Neste contexto, este estudo teve por objetivo preparar híbridos de alginato de sódio (ALG) e MMT, com AgNPs ancoradas, visando sua posterior aplicação na desinfecção de efluentes industriais para águas de reuso. Inicialmente, as AgNPs foram sintetizadas por meio da redução química de íons prata com boroidreto de sódio, na presença de citrato de sódio. Em seguida, uma suspensão contendo AgNPs, MMT e ALG foi preparada. Os híbridos de MMT-ALG-AgNPs foram obtidos a partir do gotejamento da suspensão em uma solução aquosa de cloreto de cálcio (4,0% m/v). As AgNPs, assim como os híbridos, foram caracterizados por meio das técnicas de espectroscopia de absorção na região do ultravioleta e visível (UV-Vis), microscopia eletrônica de transmissão (MET) e de varredura (MEV), espectroscopia no infravermelho com transformada de Fourier (FT-IR) e difração de raios X (DRX). O conjunto de resultados confirmou a presença da MMT, com as AgNPs ancoradas em formato esférico, dispersa na matriz de alginato. Posteriormente, foi realizado o ensaio de difusão em ágar com dois tipos de micro-organismos (Escherichia coli e Staphylococcus aureus) para se verificar o potencial bactericida desses materiais. Os ensaios mostraram que houve a formação de zonas de inibição (ZOI) para ambas as bactérias. Os híbridos foram então utilizados na desinfecção de um efluente industrial e os resultados indicaram uma redução de 98,5% em termos de coliformes totais. Por fim, o efluente industrial foi submetido a outro processo de desinfecção utilizando radiação ultravioleta (UV), que é muito comum no tratamento de águas e efluentes, com a finalidade de comparar os resultados obtidos pelos dois métodos. Verificou-se que o percentual de remoção de coliformes totais, em relação ao tempo de contato, foi aproximadamente 16% maior no tratamento com os híbridos do que com a radiação UV, confirmando o potencial do material para o objetivo proposto. / Different techniques have been developed to eliminate microorganisms from industrial wastewater and improve its final quality for reuse. Among them, the use of silver nanoparticles (AgNPs) anchored on montmorillonite (MMT) has shown good results. In this context, the aim of this study was to prepare hybrid materials from sodium alginate (ALG) and MMT, decorated with AgNPs, for application in the disinfection of industrial wastewater for reuse. Initially, AgNPs were synthesized by chemical reduction of silver ions with sodium borohydride in the presence of sodium citrate. Then, a suspension containing AgNPs, MMT, and ALG was prepared. The hybrid MMT-ALG-AgNPs was obtained from dripping the suspension in an aqueous solution of calcium chloride (4.0% w/V).The AgNPs and the hybrids were characterized by UV-visible absorption spectroscopy (UV-Vis), transmission electron microscopy (TEM), scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FT-IR), and X-ray diffraction (XRD).The set of results confirmed the presence of MMT decorated with AgNPs of spherical shape dispersed in the ALG matrix. The evaluation of the bactericidal potential of the hybrids was performed by the agar diffusion assay with two types of micro-organisms (Escherichia coli and Staphylococcus aureus). The tests evidenced the formation of a prominent zone of inhibition (ZOI) for both bacteria. The hybrids were then used in the disinfection of an industrial wastewater. The results indicated a reduction of up to 98.5% of total coliforms. For comparison bases, the industrial wastewater was subjected to another disinfection process using ultraviolet radiation (UV), which is very common in the treatment of water and wastewater. It was found that the removal of total coliforms with the hybrids was approximately 16% higher than the UV radiation, thus confirming the potential of these materials for the purpose of this work.
|
217 |
Avaliação de bactérias nitrificantes em lodos ativados de quatro estações de tratamento de diferentes efluentes industriaisPauletti, Carla Maria 05 August 2016 (has links)
Os sistemas de lodos ativados se destacam pelo fato de oferecerem a possibilidade de remoção satisfatória de nutrientes como nitrogênio e fósforo, com poucos requisitos de área. Para aperfeiçoar esse processo de remoção, o sistema pode ser otimizado a fim de alcançar satisfatórias condições de pH, temperatura, aeração, entre outros. As bactérias presentes no lodo ativado são capazes de transformar e remover o nitrogênio através dos processos de nitrificação e desnitrificação. As reações de nitrificação são catalisadas por diferentes gêneros de bactérias autotróficas, entres os quais Nitrosomonas, Nitrobacter, Nitrospira, Nitrococcus. Existem evidências mais recentes de que estas reações de nitrificação podem, em certa medida, também ser catalisadas por organismos heterotróficos. Assim, a identificação das bactérias presentes em lodos ativados de Estações de Tratamento de Efluentes (ETE), bem como o estudo dos fatores que podem ou não influenciar na eficiência do processo de remoção de nutrientes, é muito importante para a otimização do sistema. As análises físico-químicas e, posterior, análises da composição bacteriana foram realizadas em amostras de afluente, efluente e de lodo de quatro diferentes estações de tratamento. As coletas foram realizadas em ETE de dois abatedouros de aves, de uma indústria de embalagens de papel e de um hospital particular. As amostras analisadas mostraram resultados pouco similares entre si, evidenciando diferenças nos processos de nitrificação e desnitrificação conforme a ETE de origem. Os resultados encontrados para as análises físico-químicas nas amostras estudadas estiveram de acordo com os parâmetros normalmente encontrados para efluentes industriais e de acordo com os exigidos pela legislação (CONAMA, 2011), com exceção de apenas uma amostra (hospital), que teve um valor de nitrogênio amoniacal (21,23 mg/L) na saída do sistema acima do valor máximo permitido pela legislação vigente (20 mg/L). A eficiência de remoção de DQO em todas as estações de tratamento esteve na faixa entre 67,5% e 97,8%. A amostra da ETE da Indústria de Embalagens de Papel foi a que demonstrou maior eficiência de remoção de DQO (97,8%), enquanto que uma das amostras da ETE do Hospital Particular, que apresentou a maior DQO na entrada do sistema, foi a que obteve menor eficiência de remoção (67,5%). A remoção de nitrogênio amoniacal foi observada, com exceção de uma amostra, em todas as demais, e sua eficiência de remoção foi bastante variável nas amostras, com valores considerados satisfatórios para o parâmetro estudado (99,7%) e abaixo do esperado para sistemas de lodos ativados (24,6%). A menor eficiência de remoção de nitrogênio amoniacal (24,6%) foi encontrada para uma amostra da ETE Hospital, enquanto a maior eficiência se observou para a amostra da ETE Embalagens de Papel (99,7%). As amostras de lodo foram analisadas molecularmente através de nested PCR e DGGE, com posterior sequenciamento genético. Os primers utilizados na técnica de nested PCR foram: 11f e 1492r (primers universais), NIT3r (Nitrobacter), Nos1225r (Bactérias oxidadoras de amônio), Ntspa685r (Nitrospira), sendo o primer Eub338f utilizado em conjunto com os primers específicos. Já o PCR realizado para o DGGE foi realizado utilizando-se os primers 968F GC e 1392r. As análises moleculares demonstraram que as bactérias mais comuns nos processos de tratamento por lodos ativados (Bactérias oxidadoras de amônio, nitrobacter e nitrospira) estiveram presentes (pelo menos um dos gêneros) em quase todas as amostras testadas por PCR. A amostra que mostrou maior eficiência de remoção de DQO e nitrogênio amoniacal teve, também, resultado positivo para todos os primers utilizados (Bactérias oxidadoras de amônio, nitrobacter e nitrospira) na técnica de PCR, sugerindo que o processo de nitrificação foi satisfatório. Das amostras que tiveram resultado positivo para as amplificações com primers específicos para nitrificantes, apenas uma teve correspondência de resultado positivo no sequenciamento genético (Bactérias oxidadoras de amônio). / PETROBRAS, Brasil.
|
218 |
Desinfecção de efluentes de ETE com ozonio para uso agricola / Disinfection of municipal wastewater with ozone for agriultural useAssirati, Doralice Meloni 25 February 2005 (has links)
Orientadores: Bruno Coraucci Filho, Jose Roberto Guimarães / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-05T08:33:15Z (GMT). No. of bitstreams: 1
Assirati_DoraliceMeloni_M.pdf: 2605980 bytes, checksum: 5106be58d7335d014302f38a1c28070d (MD5)
Previous issue date: 2005 / Resumo: A desinfecção de águas residuárias prioritariamente ao seu uso agrícola é um processo de tratamento indispensável à proteção da saúde pública. Neste contexto, o ozônio apresenta-se como desinfetante alternativo ao cloro, já que é muito efetivo contra grande variedade de organismos patogênicos e permite minimizar a formação de subprodutos organoclorados. Neste trabalho avalia-se a efetividade do ozônio contra bactérias, protozoários e helmintos, bem como a interferência das características de qualidade do efluente sobre o processo de desinfecção. Efluentes de lagoa anaeróbia e de lagoa anaeróbia mais filtro de areia, provenientes de estação de tratamento de esgotos situada em Limeira, São Paulo, foram desinfetados em reator tubular, em escala piloto. Doses de ozônio entre 8 e 21 mg L-1 foram necessárias para adequar os efluentes de lagoa anaeróbia, de elevada carga orgânica, aos padrões estabelecidos pela OMS para reuso agrícola. Para os efluentes de filtros de areia, aeróbios e mais estabilizados, foram necessários até 4 mg L-1. Compostos que conferiram cor aos efluentes da lagoa consumiram ozônio de forma mais ou menos prioritária ao início da inativação de coliformes. Foi encontrada correlação exponencial entre este consumo e a cor verdadeira dos efluentes, com índices de correlação superiores a 90 %. A eficiência de desinfecção de coliformes totais e E.coli não foi influenciada pelo tempo de contato entre o ozônio e os efluentes tratados. Os resultados sobre a inativação de protozoários e helmintos foram considerados não conclusivos, devido à inadequação dos métodos de análise empregados. À exceção da cor e de forma geral, as características de qualidade dos efluentes não foram significativamente alteradas com a aplicação de ozônio em doses de até 34 mg L-1 para os efluentes da lagoa e 21 mg L-1 para os efluentes dos filtros de areia / Abstract: Disinfection of wastewater, prior to its use in agriculture, is a treatment process indispensable to the protection of public health. In this context, ozone constitutes an alternative disinfectant to chlorine since it is very effective against a wide variety of pathogenic organisms and minimizes the formation of trihalomethanes. In this hesis, the effectiveness of ozone against bacteria, protozoa and helminths was evaluated as well as the interference of the quality of the wastewater in the disinfection process. Effluents from an anaerobic pond and from an anaerobic pond plus an aerobic sand filter from a sewage treatment facility located in the city of Limeira in the state of São Paulo were disinfected in a plug flow pilot reactor. Ozone doses from 8 to 21 mg L-1 were needed to disinfect the anaerobic pond effluent to meet standards set by the World Health Organization for agricultural use. The sand filter effluents, aerobic and more stabilized, required up to 4 mg L-1. Colored compounds present in the anaerobic pond effluent consumed ozone more or less prior to the beginning of the inactivation of coliforms. An exponential correlation was found between the consumption of ozone and the true color of the effluents with correlation indexes higher than 90%. Contact time was found not to be a factor affecting the disinfection efficiency of ozone against total coliforms and E. coli since the mass transfer conditions were met. The results concerning the inactivation of protozoa and helminths were found to be inconclusive due to the inadequacy of the analytical methods employed. Regardless of the color, the characteristics of the effluents were not altered significantly by the doses of ozone used during the experiments, up to 34 mg L-1 for the anaerobic pond effluents and up to 21 mg L-1 for the sand filter effluents / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
|
219 |
Uso de pneu "picado" como meio suporte de leitos cultivados para o tratamento de esgoto sanitario oriundo de uma E.T.E. convencionalCollaço, Andreia de Barros 18 November 2001 (has links)
Orientadors: Denis Miguel Roston / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-06T18:38:42Z (GMT). No. of bitstreams: 1
Collaco_AndreiadeBarros_M.pdf: 886567 bytes, checksum: 4e76193e2fe87e109e097ce607c83991 (MD5)
Previous issue date: 2001 / Resumo: Este trabalho visou avaliar o comportamento de pneus picados como meio suporte em leitos cultivados, para o tratamento de esgoto sanitário doméstico. O experimento foi implantado após uma Estação de Tratamento de Esgoto (E.T.E.), que atende cerca de 260 pessoas. A estrutura para os leitos cultivados foi construída com blocos de cimento, acima do nível do solo, apresentando uma divisão, que forma dois tanques com 10 m2 cada, com dimensões de 2 m de largura, 5 m de comprimento e 1 m de altura. Como meios suportes adotou-se pedra britada de granulometria nº 3 (de 55 a 90 mm de diâmetro), e pneu picado até a altura de 80 cm, mais pedra britada para completar a altura total (1 m). Foram plantadas 50 mudas de taboa (Typha sp.) em cada leito, distribuídas em 10 linhas no sentido do comprimento, sendo que o monitoramento do sistema começou após a sua estabilização. No total, foram retiradas 12 amostras de cada leito, sendo realizadas análises laboratoriais dos seguintes parâmetros: sólidos suspensos, turbidez, pH, DBO, DQO, PO43-, P e P2O5, NH4+, NH3, NH3 ¿N, NO3-, NO3-N, coliforme total, E. coli . Os resultados obtidos foram submetidos à uma análise estatística, através de um delineamento inteiramente ao acaso, a fim de verificar se existem diferenças significativas (a 1 % e 5 % de significância) entre a pedra britada (T1) e o pneu picado (T2) empregados como meio suporte nos leitos cultivados por meio da aplicação do teste F. Estatisticamente, comprovou-se que não existem diferenças significativas a 1% e a 5 % de significância para: DBO, NH3, NH3-N, NH4+, P, PO4-3, P2O5, Coliforme total, E. coli. Enquanto que para os parâmetros de sólidos suspensos, pH, NO3-, NO3-N, turbidez, encontraram-se diferenças significativas a 1% e 5% de significância. Para a DQO, encontrou-se significativa entre os tratamentos somente a 5 % de significância. A interpretação gráfica dos valores obtidos confirmou a tendência dos resultados, comprovados estatisticamente / Abstract: This work evaluated pricked tires as a medium for constructed wetlands, treating domestic wastewater. The experiment was conducted utilizing effluent of a Sewage Treatment Plant, assisting about 260 people. Two tanks with 10 m2 each, with dimensions: of 2 m wide, 5 m long and 1 m height were built above soil level using cement bricks. One of the tanks was filled out entirely with crushed stone (diameter 55 to 90 mm), while in the other tank the medium was pricked tires reaching the height of 0.80 m. Above the tires, a 0.10 m gravel layer to complete the total height (1 m) and avoid floating. The aquatic macrophytes utilized were from Typha species distributed uniformly over the beds. The following parameters were monitored: suspended solids, pH, biochemical oxygen demand, chemical oxygen demand, phosphorus, ammonia nitrogen, nitrate, total coliform, E. coli and turbidity. The results were submitted to a statistical analysis in order to verify if significant difference existed (to 1 % and 5% of significance) between the two treatments. The results demonstrate no significant differences for the parameters BOD, NH3, NH3-N, NH4+, P, PO4-, P2O5, total coliform, and E. coli. while for suspended solids, pH, NO3, NO3-N, turbidity, were found significant differences to 1% and 5% of significance. For COD was found significant difference to 5% of significance / Mestrado / Agua e Solo / Mestre em Engenharia Agrícola
|
220 |
Filtração lenta em areia, manta não tecida e carvão ativado como pós-tratamento de efluentes domesticos e reuso / Slow sand filtration with non woven syxthetic fabric and activated carbon as after treatment of domestic sewer effluent and reuseMarrara, Danilo Aparecido Faveri 24 February 2006 (has links)
Orientador: Jose Euclides Stipp Paterniani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-06T17:36:20Z (GMT). No. of bitstreams: 1
Marrara_DaniloAparecidoFaveri_M.pdf: 739626 bytes, checksum: a356e874839131fd6c648e10f03c0b05 (MD5)
Previous issue date: 2005 / Resumo: A filtração lenta é uma alternativa viável para regiões rurais afastadas dos grandes centros urbanos que necessitam de um sistema de tratamento de água de baixo custo de implantação, assim, presente trabalho avaliou a eficiência e o desempenho da filtração lenta em uma instalação piloto de filtração em areia e manta não tecida, e carvão ativado, precedida de um pré-filtro em pedregulho para tratamento de efluente de um sistema composto um de reator anaeróbio compartimentado e de leitos cultivados (wetlands) para tratamento de esgoto doméstico. Ênfases específicas foram dadas na avaliação da Filtração Lenta com meio filtrante de areia e manta não tecida e meio filtrante de areia com camada de carvão ativado granular e manta não tecida. Para uma taxa de filtração média de 3 m3/m2.dia, obteve-se uma eficiência média na remoção de sólidos em suspensão de 36,2% para o filtro lento de carvão e areia e manta não tecida e 28,2% para o filtro lento de areia e manta não tecida. A eficiência na remoção de turbidez foi de 43,2% no filtro de carvão e areia e manta não tecida e 33,2% no filtro de areia e manta não tecida. Para a cor obteve-se uma eficiência média de 39,3% para o filtro lento com camada de carvão e areia e manta não tecida e 26,0% para o filtro lento de areia e manta não tecida. A eficiência média na remoção de coliformes totais foi de 74,6% para o filtro lento de carvão e areia e manta não tecida e de 57,6% para o filtro lento de areia e manta não tecida. A remoção média de E.coli foi de 72,7% para o filtro lento de carvão e areia e manta não tecida e de 70,8% para o filtro lento de areia e manta não tecida. Devido à simplicidade de construção e operação, o filtro lento de carvão e areia e manta não tecida pode ser aplicado para tratamento de efluentes domésticos em pequenas comunidades bem como pode ser utilizado para melhorar a qualidade de um efluente a ser lançado em corpos d¿água ou se utilizar desta tecnologia simples para tratar água para fins de reuso / Abstract: The slow sand filtration is a viable economic alternative for small communities moved away from the great urban centers. This work evaluated the efficiency of a slow filter with sand layer, activated carbon and non-woven synthetic fabric, compared with a slow filter of sand and non-woven synthetic fabric to treat constructed wetland effluent. The results had shown the removal of 74,6% of total coliforms for the slow sand filter with activated carbon and 57.6% for the slow sand filter without activated carbon. The solid reduction was 36,2% for the filter with activated carbon and 26.2% for the filter without activated carbon. For the turbidity, the reduction of 43,2% for the filter with activated carbon against 33,2% for the filter without activated carbon, and for color the filter with activated carbon got 39.3% of efficiency against 26,0% for the filter without activated carbon. Due to simplicity of construction and operation, the slow sand filter with activated carbon, sand and non-woven synthetic fabric can be applied for treatment of domestic sewer in small communities and can be used to improve the quality of an effluent to be launched in water or use this simple technology to water treatment and water reuse / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
|
Page generated in 0.0919 seconds