• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 291
  • 6
  • 6
  • 6
  • 6
  • 4
  • 3
  • 2
  • Tagged with
  • 298
  • 298
  • 298
  • 117
  • 100
  • 97
  • 83
  • 70
  • 51
  • 47
  • 44
  • 43
  • 41
  • 39
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Remoção de material carbonaceo e nitrificação em reator "air-lift" de tubos concentricos pressurizado utilizando iodo ativado

Alanis, Jean Carlo 06 April 2004 (has links)
Orientador: Ranulfo Monte Alegre / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-03T22:22:44Z (GMT). No. of bitstreams: 1 Alanis_JeanCarlo_D.pdf: 1673709 bytes, checksum: 580d9ccc57c59fa6cbb9804ec0fd65f6 (MD5) Previous issue date: 2004 / Resumo: Após a descoberta do sistema de Iodo ativado, vários pesquisadores contribuíram de forma primordial para o aperfeiçoamento dos sistemas, tanto em termos de eficiência de remoção,como na capacidade de tratamento por unidade de volume do sistema, além de aumentarem a estabilidade operacional do mesmo. A finalidade do presente trabalho consistiu num estudo de métodos de tratamento de águas residuária sem reator "air-lift"pressurizado construído em aço inox, com tubos de aeração e reciclo de 1,2 e 1,5 m respectivamente.O reator foi alimentado com água residuária sintética com concentrações variáveis ao longo de sete experimentos realizadose o Iodo separado em sedimentadorlocalizado na parte superior para ser recirculadoao sistema. O reator foi operado continuamente até que o estado estacionário hidráulico e crescimento microbiano fossem atingidos a cada variação na concentração do substrato. A pressão manométrica no reator foi de 1,25 kgf.cm-2,a vazão de ar entre 1300 (experimentos 1, 2, 3 e 4) a 500 mL.min-1(experimentos5,6 e 7), e vazão de substrato de aproximadamente 380 mL.h-1. A metodologia utilizada nas análises está descrita no "Standard Methods for the Examinationof Water and Wastewater" (1995). Foram analisados a Demanda Química de Oxigênio (DQO), concentração da biomassa (sólidos suspensos voláteis - SSV), Nitrito, Nitrato, Nitrogênio Total e AmoniacaL A concentração de DQO do substrato variou inicialmentede 2890 a 8700 mgDaO.L-1, o que significa que o reator foi operado com concentração de Iodo igual à concentração obtida em sedimentadores convencionais de Iodo, tratando água residuária com DQO muito além do limite usual dos Iodos ativados convencionais. Esse aumento na concentração de DQO do substrato possibilitou um aumento significativo da contentração de biomassa no reator em até 10500 mgSSV.L-1. Com este aumento, verificou-se um incremento na eficiência de redução da DQO em até 99%. / Abstract: After the discovery of activated sludge system, several researchers made important contribution to improve systems not only in efficiency, but also in treatment capability per unit of system volume, besides they increase operational stability of the system. The objective of this work was to study methods of wastewater treatment in pressurized air lift reactor built in stainless steel with aeration pipes and downcomer of 1,2 and 1,5 m respectively. Reactor was feed with synthetic wastewater in concentrations that varied during seven experiments and sludge was separated in sedimentator at upper part for being recycled to the system. Reactor was carried out continuously until hydraulic stationary state and microbial growth were reached out each variation on substrate concentration. Manometric pressure in reactor was 1,25 kgf.cm-2, air fIow rate from 1300 (experiments 1,2,3 and 4) to 500mL.min-1(experiments 5, 6 and 7) and substrate flow rate about to 380 mL.h-1.The samples were analyzed by the methodology in analysis is described on "Standard Methods for Examination of Water and Wastewater" (1995). Chemical Oxygen Oemand (COO), biomass concentration (Volatile Suspended Solids - VSS), nitrite, nitrate, total and ammoniacal nitrogen were analyzed. The COO concentration of the substrate varied initially from 2890 to 8700 mg COO.L-1and the reactor was operated with sludge concentration equal to obtained in conventional sludge sedimentator, using high COO concentration of a significant increase of biomass concentration on reactor about 10500 mg VSS.L-1 was observed. With this increase it was verified an increment in efficiency of COO removal about 99%. / Doutorado / Doutor em Engenharia de Alimentos
22

Uso de leitos cultivados no tratamento de efluente de tanque septico modificado

Valentim, Marcelus Alexander Acorinte 24 July 2018 (has links)
Orientador: Denis Miguel Roston / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-07-24T13:02:19Z (GMT). No. of bitstreams: 1 Valentim_MarcelusAlexanderAcorinte_M.pdf: 1687002 bytes, checksum: 89ae729a76ec7dd42dc9b91fe3b24598 (MD5) Previous issue date: 1999 / Resumo:O presente trabalho visou projetar, construir e avaliar por um período de 4,5 meses (set/98 a jan/99) o desempenho de um tanque séptico de três compartimentos em série modificado (conceito dos reatores anaeróbios compartimentados) e de leitos cultivados com macrófitas (sistema aquático natural) no tratamento de águas residuárias brutas da Faculdade de Engenharia Agrícola (FEAGRI) da Universidade Estadual de Campinas-UNICAMP, localizada em Campinas (SP). O resíduo líquido desta Faculdade é composto de uma mistura de dejetos domésticos e sanitários com águas residuárias de lavagem de vidrarias dos laboratórios e de equipamentos da oficina mecânica, com sua vazão acompanhando o ritmo do expediente, iniciando por volta das 7:30h, crescendo continuamente até atingir seu máximo entre 15:30h e 16:30h e decrescendo a partir deste ponto até às 21:00h, e sendo praticamente inexistente nos finais de semana e feriados. O experimento foi composto de um tratamento primário, tanque séptico modificado de três compartimentos em série, tendo como característica a entrada do efluente junto ao fundo dos compartimentos, volume total de 2000L e vazão diária média de 1330 L (9 PE), obtendo redução de DQO entre 17 e 69%, sólidos sedimentáveis de 100%, sólidos suspensos entre 58 e 92%, turbidez entre 67 e 92% e E. coli de 0 a 75%. Como tratamento secundário foram construídos, em blocos de concreto e acima do solo, seis leitos cultivados com macrófitas, três de forma retangular e três quadrada, dispostos em paralelo, com o mesmo tipo de brita (no 2 ¿ 55 a 90mm) utilizada como meio suporte e cultivados com duas espécies de macrófitas emergentes (Typha sp. ou Eleocharis sp.) e de fluxo subsuperficial. A área de cada leito é de 4,0 m2 e altura de 0,70m. Um leito quadrado e outro retangular permanecerão sem cultivo para controle. Os leitos com os maiores valores de remoção foram o quadrado plantado com Eleocharis sp., com redução de sólidos suspensos entre 91 e 97%, coliformes totais de 59 a 96%, nitrogênio total Kjeldahl de 35 a 90% e fósforo total de 41 a 65%, o controle retangular, com redução de turbidez de 87 a 98% e nitrogênio amoniacal de 35 a 87%, o retangular plantado com Eleocharis sp., com redução de DQO entre 70 e 97% e E. coli entre 94 e 97%, e o quadrado plantado com Typha sp., com redução de nitrato de 71 a 83%. Quanto à adaptação das macrófitas cultivadas nos leitos, a Eleocharis sp. mostrou-se mais vigorosa que a Typha sp. com lançamento de brotos, crescimento e espalhamento nos leitos mais intenso em condições adversas, devido às características peculiares da espécie / Abstract: This study has evaluated the performance of three compartment septic tank followed by a constructed wetland in the treatment of the raw sewage from the School of Agricultural Engineering (University of Campinas ¿ Brazil). Experiments were carried out over a period of 4.5 months (sept/98 to jan/99). The concept of compartments anaerobic reactor was applied to design the septic tank. The inflow to the compartments was located near the bottom in order to provide better contact between microorganisms and wastewater. The results indicated COD removal ranging from 17 to 69%; settable solids removal up to 100%; suspended solids ranging from 58 to 92%; turbidity from 67 to 92%; and E. coli ranging from zero to 75%. As secondary treatment were constructed six subsurface flow wetlands (Area= 4.0 m2, depth 0.7m), 3 with square shape and 3 rectangular. The units were constructed above soil level with concrete bricks. The medium used was gravel with size ranging from 55 to 90 mm and macrophytes from two species Typha sp. and Eleocharis sp. Better results were achieved in the square unit planted with Eleocharis sp. with suspended solids removal ranging from 91 to 97%, total coliformes from 59 to 96%, Kjedahl nitrogen ranging from 35 to 90% and total phosphorus ranging from 41 to 65%; the unplanted rectangular unit presented turbidity reduction ranging from 87 to 98% and Ammonia nitrogen ranging from 35 to 87%; the rectangular unit planted with Eleocharis sp. presented COD removal ranging from 70 to 97% and E. coli between 74 and 97%; the square unit planted with Typha sp, presented nitrate removal ranging from 71 to 83%. The Eleocharis sp. showed faster propagation in the units compared to the Typha s / Mestrado / Agua e Solo / Mestre em Engenharia Agrícola
23

Estudo sobre tratamento de aguas residuais de lacticinios

Roston, Denis Miguel, 1951- 09 December 1985 (has links)
Orientador : Irenilza de Alencar Naas / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-07-17T21:35:15Z (GMT). No. of bitstreams: 1 Roston_DenisMiguel_M.pdf: 3881387 bytes, checksum: e9a4d30c762ab2213714852f4a4a432a (MD5) Previous issue date: 1985 / Mestrado / Mestre em Ciências Agrícolas
24

Tratamento físico-químico de efluentes de curtume por meio de filtros de membrana seletiva /

Geromel, Camila Gabriela Alexandre. January 2012 (has links)
Orientador: Tsunao Matsumoto / Banca: Dib Gebara / Banca: Luís Fernando Rossi Léo / Resumo: Historicamente, as indústrias de curtimento de couro são consideradas extremamente poluidoras devido aos seus rejeitos com altas concentrações de matéria orgânica e metais pesados, características que influenciam em vários parâmetros de análise de efluentes, tais como DBO, DQO e sólidos totais. Vários trabalhos foram desenvolvidos, tendo como objeto de estudo o efluente da empresa Fuga Couros Jales Ltda, sediada no município de Jales/SP. O reator anaeróbio UASB em etapa única foi utilizado primeiramente, como dispositivo de tratamento, e posteriormente foi analisado este mesmo reator combinado a pré-tratamento físico químico e pós-tratamento biológico, no entanto nenhum deles apresentou satisfatória eficiência da remoção de DBO, assim como também não atenderam as exigências da legislação vigente, em praticamente quase todos os parâmetros analisados. O presente trabalho teve como objeto de estudo o efluente deste Curtume e seu objetivo principal foi reduzir a carga de compostos de enxofre por oxidação química e reduzir a carga orgânica e de sólidos nas etapas de coagulação-floculação-sedimentação com posterior separação por membrana microfiltrante, e a redução dos sólidos remanescentes no efluente, na etapa de ultrafiltração por membrana, a concentrações aceitáveis para o descarte de efluentes. Para tanto, foram analisados previamente em jar-test uma faixa de pH adequada de trabalho para adição de cloreto férrico e o policloreto de alumínio, assim como analisar seus comportamentos quanto à eficiência de remoção de sólidos e, com relação ao peróxido de hidrogênio, permanganato de potássio e sulfato manganoso quanto à sua eficiência na oxidação de sulfeto. Posteriormente, foram analisadas as interações entre cada um destes reagentes e, em posse dos resultados destas análises, optou-se por aplicar o sulfato... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Historically, the industries of leather tanning are considered highly polluting due to its tailings with high concentrations of organic matter and heavy metals, characteristics that influence on several effluent parameters, such as BOD, COD and total solids. Several studies have been developed, object of to study, the effluent from the company Fuga Couros Jales Ltda, whose locate in Jales/SP city, Brazil. The UASB reactor in single step was used on time first as a treatment device, and later the same reactor combined physical and chemical pre-treatment and post-biological treatment, however none showed removal efficiencies of DBO satisfactory, and also did not reached the goal of the current legislation practically in all analyzed parameters. This research had as object of its study the tannery effluent and its main goal was to reduce the sulfur compounds concentration by chemical oxidation, organic loading and solids reduction in the stages of coagulation-flocculation-sedimentation with subsequent microfiltration membrane separation, and, the reduction of solids still remaining in the wastewater, in ultrafiltration membrane step to acceptable concentrations for effluent disposal. Therefore, were analyzed previously in Jar-Test a pH range suitable for working with the ferric chloride and polyaluminium chloride, and, analyzing their behavior as regards the solids removal efficiency and, with respect to hydrogen peroxide, potassium permanganate and manganous sulfate as the efficiency in the sulfide oxidation. Subsequently, we analyzed the interactions between each of these reagents, and ownership of the results of these analyzes, we chose to apply the manganous sulfate and ferric chloride to the physical-chemical treatment. The proposed treatment presents a good sulfide and suspended solids removal (62% and 96%.), However... (Complete abstract click electronic access below) / Mestre
25

Proposição de metodologia para determinação de parametros de projeto e operação de reatores biologicos de lodos ativados por batelada

Pereira, Renata Ugliani Henrique 08 August 1996 (has links)
Orientador: Carlos Gomes da Nave Mendes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-21T13:06:41Z (GMT). No. of bitstreams: 1 Pereira_RenataUglianiHenrique_M.pdf: 2973368 bytes, checksum: fca632d0fdd3c4a40c10b751115ea1a7 (MD5) Previous issue date: 1996 / Resumo: o uso de reatores biológicos tipo lodos ativados por batelada (LAB), vem sendo intensificado nos últimos anos em vários países, pela sua simplicidade operacional, possibilidade de automação, flexibilidade de estratégias de operação que podem permitir a remoção de nutrientes principalmente (N e P) e obtenção de choques devido aos picos de cargas volumétricas e/ou orgânicas, baixa produção de lodo e alta eficiência de remoção de compostos orgânicos, aliado à economia de energia e implantação comparada com os sistemas de lodos ativados convencionais e suas variantes. No entanto, porém, não existem, parâmetros e modelos matemáticos bem definidos que possam ser aplicados ao projeto e operação desse tipo de sistema, e neste trabalho, apresenta-se e testa-se com sucesso, uma nova modelagem matemática para projeto e operação desse tipo de sistema, além de uma nova metodologia de desenvolvimento de estudos de tratabilidade em reatores piloto, de forma que possam ser estabelecidos parâmetros otimizados que permitam a determinação das seguintes variáveis: a) número ideal de reatores que devem compor uma bateria; b) volume ideal de cada reator; c) parcela do volume total de cada reator que deve ser reservada para preservação do lodo ativado; d) duração ideal de um ciclo total de tratamento e respectivas percentagens desse período destinado às operações de enchimento e reação... Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: The use of sequencing batch reactors (SBR) of activated sludge has increased in many countries because of the operational simplicity and the automation possibilities. An operacional strategy flexibility allowed nutrients removal (N and P), absortion of volumetric and/or organics load picks, sludge low production and high efficiency of organics compounds. SBR is more economic for building and operation than conventional activated sludges systems. Nevertheless, the SBR system lacks of mathematical parameters and modes definition. In the present work, a new mathematic model to design and operation of this tecnology and a methodology to execute pilot investion in laboratory reactors was tested with success. The new method can predict and optimize the follow parameter: a) reactors number in a full scale wastewater treatment plant; b) volume of each reactors; c) portion of the volume to preserve the sedimented activated sludge at the end of the cyde; d) ideal extend of the total fill and react periods of one cyde treatment... Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Recursos Hidricos e Saneamento / Mestre em Engenharia Civil
26

Estudo sobre a aplicabilidade da cinetica do tratamento biologico a reatores de lodos ativados por batelada

Yamassaki, Claudia Mayumi 31 July 1996 (has links)
Orientador: Carlos Gomes da Nave Mendes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-21T14:00:08Z (GMT). No. of bitstreams: 1 Yamassaki_ClaudiaMayumi_M.pdf: 4365383 bytes, checksum: 6e6b0dc5fc3eb0392d0a50a01171c64f (MD5) Previous issue date: 1996 / Abstract: The use of sequencing batch reactors (SBR) has increased in many countries because of the operational simplicity and the automation possibilities. An operational strategy flexibility allowed nutrients removal (N and P), absortion of volumetric and/or organics load picks, sludge low production and high efficiency of organics compounds. SBR is more economic for building and operation than conventional activated sludges systems. Nevertheless, the SBR system lacks of mathematical parameters and models definition. The present work analysed the kinetic coefficients of aerobic digestion in continuos flow activated sludge. A methodology for the determination of kinetic coefficients for intermitent flow activated sludge, using the sludge age, was tested. The kinetic coefficients were determined for both biologic reactors using chemical painting wastewater. Each reactor has a different coefficient. ...Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Recursos Hidricos e Saneamento / Mestre em Engenharia Civil
27

Desempenho do reator batelada sequencial nos processos de nitrificação e desnitrificação

Moreira, Mauro de Paula 04 June 2001 (has links)
Orientador : Ranulfo Monte Alegre / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-07-28T00:35:06Z (GMT). No. of bitstreams: 1 Moreira_MaurodePaula_D.pdf: 27752894 bytes, checksum: 99102d140dea3b370d6d32fe4ca4b978 (MD5) Previous issue date: 2001 / Resumo: Estudou-se o desempenho de um Reator Batelada Sequencial (RBS) aplicado ao tratamento de água residuária de abatedouro avícola, utilizando várias estratégias de operação, com o objetivo de reduzir a carga carbonácea e promover a remoção dos macronutrientes. Em alguns experimentos, adicionou-se uma fonte de carbono no início da fase anóxica para promover a redução de nitrato por processo de desnitrificação. No início de cada experimento o reator partia com dois litros de licor misto e era alimentado até que se atingisse quatro litros. Em experimentos com ciclo de 21 horas, nos quais foram adicionados 300 mL de água residuária bruta como fonte de carbono interna no . início da fase anóxica, obteve-se redução de DQO, fósforo, amônia, nitrito e nitrato de 85%, 76%, 32%, 54% e 70% a 25°C, respectivamente. Quando foi utilizada solução de acetato de sódio de 190 mg DQO/L como fonte de carbono externa, obteve-se redução de DQO, fósforo, amônia, nitrito e nitrato de 72%, 90%, 41%, 65% e 73%, respectivamente. Em experimentos com ciclo de 12 horas, sem fase anóxica, que não foram adicionadas fonte de carbono, obteve-se redução de DQO, fósforo, amônia, nitrito e nitrato de 81%, 86%, 83%, 54% e 72%, respectivamente, sendo esta a estratégia de operação que mostrou ser a mais adequada para remoção de DQO e macronutrientes simultaneamente. Estes resultados mostraram que ocorreu desnitrificação na fase de reação aerada, contrariando informações da literatura que relatam que a desnitrificação ocorre em fase anóxica. A remoção de matéria carbonácea e macronutrientes depende da duração e ordem das etapas, bem como da condição de partida do reator, porém as características da água residuária bruta e do lodo biológico também influenciam o desempenho do reator / Abstract: The performance of the feed batch reactor applied to poultry wastewater treatment was investigated. Several strategies of reactor operation were used to reduce the carbon demand and macronutrients, inc1udingthe addition of a carbon source at the beginning of the anoxic step to promote the nitrate reduction and the denitrification. At the beginning of each experiment the reactor started with two litres of mixed liquor and it was fed with wastewater until final volume of four litres. The COD, phosphorus, ammonia, nitrite and nitrate reduction reached 85%, 76%, 32%, 54% and 70% at 25°C, respectively, in experiments with duration of 21 hours in which 300 mL of raw wastewater were added at the beginning of the anoxic step as carbon source. When it was added sodium acetate solution to increase the COD in 190 mg COD/L as carbon source, the reduction of COD, phosphorus, ammonia, nitrite and nitrate reached values of 72%, 90%, 41%, 65% and 73%, respectively. The best operation strategy to simultaneously COD and macronutrients reduction showed to be experiments with 12 hours of duration without anoxic step and addition of carbon source, when the COD, phosphorus, ammonia, nitrite and nitrate reduction reached 81%, 86%, 83%, 54% and 72 , respectively. These results showed that the denitrification occurred in oxic phase despite the literature reports that asseverate that denitrification occurs only in anoxic phase. The duration and order of the steps of the sequencing batch reactor as well the initial condition at each run beginning influence the carbon and macronutrients remova!, beside the wastewater and sludge characteristics / Doutorado / Doutor em Engenharia de Alimentos
28

Otimização do tratamento de efluente lácteo sintético com o uso de coagulantes alternativos / Optimization of the treatment of synthetic dairy effluent with the use of alternative coagulants

Muniz, Gustavo Lopes 21 February 2018 (has links)
Submitted by MARCOS LEANDRO TEIXEIRA DE OLIVEIRA (marcosteixeira@ufv.br) on 2018-08-01T20:14:46Z No. of bitstreams: 1 texto completo.pdf: 3556093 bytes, checksum: 27a4adab796975b555ffecbaf82dffd7 (MD5) / Made available in DSpace on 2018-08-01T20:14:46Z (GMT). No. of bitstreams: 1 texto completo.pdf: 3556093 bytes, checksum: 27a4adab796975b555ffecbaf82dffd7 (MD5) Previous issue date: 2018-02-21 / Os laticínios geram, diariamente, elevados volumes de águas residuárias que são originadas das limpezas das instalações e da fabricação de produtos. Estas águas caracterizam-se por apresentar concentrações elevadas de nutrientes, gorduras, sólidos suspensos e dissolvidos, demanda bioquímica (DBO) e química de oxigênio (DQO) e pH que varia em função do que é produzido e dos produtos utilizados na higienização deste tipo de empreendimento. Dentre os métodos disponíveis para tratamento dos efluentes lácteos, destaca-se o Tratamento Primário Quimicamente Assistido (TPQA), conhecido também como CEPT (Chemically Enhanced Primary Treatment). No TPQA coagulantes químicos são adicionados na etapa do tratamento primário a fim de aprimorar a remoção de poluentes. Entretanto, a aplicação de coagulantes químicos tem gerado um inconveniente às indústrias e estações de tratamento que utilizam este método, que é a produção de grandes volumes de lodo com características tóxicas e não biodegradável. Alguns resíduos agroindustriais, como o quiabo (Abelmoschus esculentus), sementes de maracujá (Passiflora edulis), resíduos da carcinocultura e as cascas da mutambeira (Guazuma ulmifolia) apresentam elevado potencial para serem utilizados como coagulantes alternativos no tratamento de efluentes, devido às suas características químicas. O emprego de coagulantes no tratamento de efluentes envolve a otimização da dose de coagulante e do pH, uma vez que influenciam, diretamente, na eficiência de remoção de poluentes. Para isso, métodos de superfície de resposta (MSR) vêm sendo utilizados na otimização dessas variáveis. Assim, o objetivo deste estudo foi avaliar a eficiência de coagulantes naturais no tratamento de efluente lácteo sintético (ELS) via flotação por ar dissolvido (FAD), otimizando as condições operacionais de dose de coagulante e pH na remoção da turbidez, DQO e compostos orgânicos que absorvem na região do ultravioleta no comprimento de onda 254 nm (compostos UV 254 ) e comparar planejamentos estatísticos na descrição dos resultados. Em primeiro momento comparou-se dois planejamentos experimentais, a matriz de Doehlert e o delineamento composto central rotacional (DCCR) na descrição de remoção de poluentes do ELS, utilizando dois coagulantes orgânicos, o Tanfloc e a poliacrilamida (PAM). Observou-se nos resultados obtidos que ambos os planejamentos geraram modelos matemáticos significativos (p ≤ 0,05) e com elevada capacidade de predição. Além disso, foi verificado que o ponto ótimo obtido para remoção de poluentes foi próximo entre os planejamentos, observando, porém, pequena diferença entre as dosagens de coagulantes. Em segundo momento foi avaliado a eficiência dos coagulantes obtidos do extrato do quiabo, das sementes de maracujá, a quitosana e as cascas da mutambeira na remoção da turbidez, DQO e compostos UV 254 do ELS, otimizando as condições de dose de coagulante e de pH através do DCCR para os dois primeiros e da matriz de Doehlert para os demais. Foi observado que os coagulantes estudados são eficientes na remoção de poluentes do ELS, sendo a eficiência diretamente relacionada ao pH e à dose de coagulante aplicada. Os pontos ótimos de remoção de poluentes encontrados foram: 2,0 g L -1 de extrato de quiabo em pH 9,00; com eficiência de remoção de turbidez e DQO de 91,1 e 48,3%, respectivamente; 1,3 g L -1 de extrato de semente de maracujá em pH 5,00; com eficiência de remoção de turbidez e DQO de 91,5 e 50,3%, respectivamente; dose de quitosana igual a 73,34 mg L -1 em pH 5,00; com eficiência de remoção da turbidez, DQO, e compostos UV 254 de 97,6; 77,5 e 88,8%, respectivamente e 775,8 mg L -1 de cascas de mutambeira em pH 5,00; com eficiência de remoção de turbidez, DQO e compostos UV 254 de 95,8; 76,0 e 85,6%, respectivamente. Assim, quando aplicados na condição ideal, os coagulantes testados apresentam potencial para substituir os coagulantes químicos atualmente comercializados, minimizando, assim, o passivo ambiental. / Dairies, daily, generate high volumes of wastewater from cleaning site and manufacturing products. These waters have high concentrations of nutrients, fats, suspended and dissolved solids, biochemical oxygen demand (BOD) and chemical oxygen demand (COD) and pH that varies according to what is produced and the products used in the sanitation of this type of enterprise. Among the available methods for the treatment of dairy effluents, stands out the Chemically Enhanced Primary Treatment (CEPT). In CEPT, chemical coagulants are added in the primary treatment step in order to improve the removal of pollutants. However, the application of chemical coagulants generates high volumes of toxic and not biodegradable sludge. Some agroindustrial residues, such as okra (Abelmoschus esculentus), passion fruit seeds (Passiflora edulis), shrimp waste and bark of Guazuma ulmifolia have potential to be used as alternative coagulants in the treatment of effluents, due to their chemical characteristics. The use of coagulants in the treatment of effluents involves the optimization of the coagulant dosage and pH, once they directly influence in the efficiency of pollutants removal. For this, surface response methodology (SRM) have been used in the optimization of these variables. Thus, the objective of this study was to evaluate the efficiency of natural coagulants in the treatment of synthetic dairy effluent (SDE) by dissolved air flotation (DAF), optimizing the operational conditions of coagulant dose and pH in the removal of turbidity, as well as COD and organic compounds that absorb in the ultraviolet region at a wavelength of 254 nm (UV 254 compounds) and compare statistical design in the description of results. At first, two experimental designs were compared, the matrix of Doehlert and Central Composite Rotational Design (CCRD), in the description of pollutants removal of SDE using two organic coagulants, Tanfloc and polyacrylamide. It was observed in the obtained results that the both plans generated significant mathematical models (p ≤ 0,05) and with high predictive capacity. Furthermore, it was verified that the optimum point obtained for the removal of pollutants was close between the designs, noting, however, a small difference between the coagulant dosages. Secondly, was evaluate the efficiency of the coagulants obtained from the okra extract, passion fruit seeds, chitosan and bark of Guazuma ulmifolia in the removal of turbidity, COD and UV 254 compounds of SDE. The coagulant dosage and pH conditions were optimized through the CCDR for the first two extracts and the Doehlert matrix for the others. It was observed that the coagulants studied are efficient in the removal of SDE pollutants, once the efficiency is directly related to the pH and the coagulant dosage applied. The optimal points of removal of pollutants were: 2,0 g L -1 extract of okra in pH 9,00; with removal efficiency of turbidity and COD of 91,1 and 48,3%, respectively; 1,3 g L -1 passion fruit seeds extract in pH 5,00; with removal efficiency of turbidity and COD of 91,5 e 50,3%, respectively; 73,34 mg L -1 dose of chitosan in pH 5,00; with removal efficiency of turbidity, COD and UV 254 compounds of 97,6; 77,5 e 88,8%, respectively and 775,8 mg L -1 of Guazuma ulmifolia bark in pH 5,00; with removal efficiency of turbidity, COD and UV 254 compounds of 95,8; 76,0 e 85,6%, respectively. Thus, when applied in the optimum condition, the coagulants tested have potential to replace the currently marketed chemical coagulants, minimizing, this way, environmental liability.
29

Otimização de métodos oxidativos no tratamento de soluções de corante reativo Procion vermelho HE-3B para reutilização em novos tingimentos de algodão /

Balbinot, Elaine Teresinha, 1980-, Barcellos, Ivonete Oliveira, 1962-, Peralta-Zamora, Patrício Guillermo, Universidade Regional de Blumenau. Programa de Pós-Graduação em Química. January 2008 (has links) (PDF)
Orientador: Ivonete O. Barcellos. / Co-orientador: Patrício Peralta Zamora. / Dissertação (mestrado) - Universidade Regional Blumenau, Centro de Ciências Exatas e Naturais, Programa de Pós-Graduação em Química.
30

Avaliação da utilização de sistemas de alagados construídos como sistema de tratamento terciário de efluentes e para geração de biomassa da cultura de taboa (Typha sp)

Pereira, Ricardo Molto [UNESP] 12 December 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:46Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-12-12Bitstream added on 2014-06-13T19:25:23Z : No. of bitstreams: 1 000759422.pdf: 6836916 bytes, checksum: 42fbf03992ee57a09d868b3a8f767c83 (MD5) / O problema de eutrofização dos cursos d’água, devido ao lançamento de efluentes sem o tratamento terciário, tem causados inúmeros danos sociais, ambientais e econômicos. Visando este cenário o sistema de Alagados Construídos é uma das alternativas para efetuar a remoção dos poluentes do tipo nutrientes do efluente, podendo aproveitá-los para a produção de biomasssa, que após o manejo pode ser utilizada como fonte de energia em termoelétricas. O trabalho aqui apresentado teve como objetivo avaliar o sistema de alagados construídos do Jardim Botânico do município de Bauru-SP, através das métricas de crescimento e desenvolvimento das plantas, cruzando estas informações com dados climatológicos locais e dados disponíveis na literatura em relação à espécie Typha sp. Com isto foi possível chegar às equações de correlação entre as métricas de comprimento e largura das folhas, a área foliar, com a produção de massa seca, absorção de nitrogênio, fósforo, potássio, sódio e incorporação de carbono fixo pela planta. Possibilitando a determinação de parâmetros de dimensionamento do sistema, a partir estas taxas. / The eutrophication of watercourses due to discharge of effluents without tertiary treatment, has caused severe damage, such as social, environmental and economic. Aiming this scenario, the Constructed Wetlands Systems is an alternative to effect removal of pollutants like nutrients and may make use of them for producing of biomasss , which after handling can be used as a source of energy in thermoelectrics. This work intends evaluate the constructed wetland system of Jardim Botânico in Bauru-SP, through measurements of growth and development of plants, crossing this information with local climatological data and available data in the literature concerning of species Typha sp. With this it was possible to reach at equations of correlation between the metrics of length and width of leaves, leaf area, with dry matter yield, nitrogen absorption, phosphorus, potassium, sodium and incorporation of carbon fixed by the plant. Enabling the determination of parameters of the system design, from the absorption rates of the plants.

Page generated in 0.0867 seconds