Uso de leitos cultivados no tratamento de efluente de tanque septico modificadoValentim, Marcelus Alexander Acorinte 24 July 2018 (has links)
Orientador: Denis Miguel Roston / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-07-24T13:02:19Z (GMT). No. of bitstreams: 1
Valentim_MarcelusAlexanderAcorinte_M.pdf: 1687002 bytes, checksum: 89ae729a76ec7dd42dc9b91fe3b24598 (MD5)
Previous issue date: 1999 / Resumo:O presente trabalho visou projetar, construir e avaliar por um período de 4,5 meses (set/98 a jan/99) o desempenho de um tanque séptico de três compartimentos em série
modificado (conceito dos reatores anaeróbios compartimentados) e de leitos cultivados com macrófitas (sistema aquático natural) no tratamento de águas residuárias brutas da Faculdade de Engenharia Agrícola (FEAGRI) da Universidade Estadual de Campinas-UNICAMP, localizada em Campinas (SP). O resíduo líquido desta Faculdade é composto de uma mistura de dejetos domésticos e sanitários com águas residuárias de lavagem de vidrarias dos laboratórios e de equipamentos da oficina mecânica, com sua vazão acompanhando o ritmo do expediente, iniciando por volta das 7:30h, crescendo continuamente até atingir seu máximo entre 15:30h e 16:30h e decrescendo a partir deste ponto até às 21:00h, e sendo praticamente inexistente nos finais de semana e feriados. O experimento foi composto de um tratamento primário, tanque séptico modificado de três compartimentos em série, tendo como característica a entrada do efluente junto ao fundo dos compartimentos, volume total de 2000L e vazão diária média de 1330 L (9 PE), obtendo redução de DQO entre 17 e 69%, sólidos sedimentáveis de 100%, sólidos suspensos entre 58 e 92%, turbidez entre 67 e 92% e E. coli de 0 a 75%. Como tratamento secundário foram construídos, em blocos de concreto e acima do solo, seis leitos cultivados com macrófitas, três de forma retangular e três quadrada, dispostos em paralelo, com o mesmo tipo de brita (no 2 ¿ 55 a 90mm) utilizada como meio suporte e cultivados com duas espécies de macrófitas emergentes (Typha sp. ou Eleocharis sp.) e de fluxo subsuperficial. A área de cada leito é de 4,0 m2 e altura de 0,70m. Um leito quadrado e outro retangular permanecerão sem cultivo para controle. Os leitos com os maiores valores de remoção foram o quadrado plantado com Eleocharis sp., com redução de sólidos suspensos entre 91 e 97%, coliformes totais de 59 a 96%, nitrogênio total Kjeldahl de 35 a 90% e fósforo total de 41 a 65%, o controle retangular, com redução de turbidez de 87 a 98% e nitrogênio amoniacal de 35 a 87%, o retangular plantado com Eleocharis sp., com redução de DQO entre 70 e 97% e E. coli entre 94 e 97%, e o quadrado plantado com Typha sp., com redução de nitrato de 71 a 83%. Quanto à adaptação das macrófitas cultivadas nos leitos, a Eleocharis sp. mostrou-se mais vigorosa que a Typha
sp. com lançamento de brotos, crescimento e espalhamento nos leitos mais intenso em condições adversas, devido às características peculiares da espécie / Abstract: This study has evaluated the performance of three compartment septic tank followed by a constructed wetland in the treatment of the raw sewage from the School of Agricultural Engineering (University of Campinas ¿ Brazil). Experiments were carried out over a period of 4.5 months (sept/98 to jan/99). The concept of compartments anaerobic reactor was applied to design the septic tank. The inflow to the compartments was located near the bottom in order to provide better contact between microorganisms and wastewater. The results indicated COD removal ranging from 17 to 69%; settable solids removal up to 100%; suspended solids ranging from 58 to 92%; turbidity from 67 to 92%; and E. coli ranging from zero to 75%. As secondary treatment were constructed six subsurface flow wetlands (Area= 4.0 m2, depth 0.7m), 3 with square shape and 3 rectangular. The units were constructed above soil level with concrete bricks. The medium used was gravel with size ranging from 55 to 90 mm and macrophytes from two species Typha sp. and Eleocharis sp. Better results were achieved in the square unit planted with Eleocharis sp. with suspended solids removal ranging from 91 to 97%, total coliformes from 59 to 96%, Kjedahl nitrogen ranging from 35 to 90% and total phosphorus ranging from 41 to 65%; the unplanted rectangular unit presented turbidity reduction ranging from 87 to 98% and Ammonia nitrogen ranging from 35 to 87%; the rectangular unit planted with Eleocharis sp. presented COD removal ranging from 70 to 97% and E. coli between 74 and 97%; the square unit planted with Typha sp, presented nitrate removal ranging from 71 to 83%. The Eleocharis sp. showed faster propagation in the units compared to the Typha s / Mestrado / Agua e Solo / Mestre em Engenharia Agrícola
|
2 |
A Influência do pH e da dureza sobre a inibição do ciclo de vida do microcrustáceo moina micrura (Kurz, 1874) em um tanque de decantaçãoStockmann, César 25 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2010 / Made available in DSpace on 2012-10-25T14:37:37Z (GMT). No. of bitstreams: 1
289278.pdf: 1454344 bytes, checksum: 8265a7198056bed7ac1c1303669064b1 (MD5) / Uma problemática encontrada pela empresa CLE Brasil, situada no litoral norte do estado de Santa Catarina, foi a presença do microcrustáceo Moina micrura (Kurz, 1874) no tanque decantador do sistema de tratamento de efluentes. Em grande densidade, esse organismo causa um aumento da concentração dos sólidos sedimentáveis em suspensão, necessitando de intervenções operacionais de limpeza no sistema para redução da população do microcrustáceo a fim de manter o efluente tratado dentro dos limites da legislação estadual. Na tentativa de solucionar o problema, nosso estudo avaliou a influência do pH e da dureza sobre a inibição do ciclo de vida do microcrustáceo Moina micrura, utilizando três variações para o pH (5,0; 7,0; 9,0) e quatro variações para a dureza (30; 65; 130; 260mg CaCO3/L), com dez repetições cada, com 1 indivíduo por unidade experimental. Verificou-se a influência sobre o total de indivíduos gerados por fêmea, sobre o número de desovas por fêmea e sobre a longevidade dos microcrustáceos para os diferentes tratamentos. Para as três variações de pH analisadas, não foi observada diferença significativa entre os tratamentos para o total de indivíduos gerados por fêmea e sobre o número de desovas por fêmea (p<0,05), porém para o tratamento pH = 5,0 houve maior mortalidade (menor longevidade). O tratamento dureza 30mg CaCO3/L apresentou o menor número de organismos gerados por fêmea e o menor número de desovas totais por fêmea (p<0,05); para os tratamentos de dureza 65 e 130mg CaCO3/L ocorreu um valor intermediário no número de organismos gerados por fêmea e, para o tratamento dureza 260mg CaCO3/L, ocorreu o maior número de organismos gerados por fêmea. Os tratamentos 65, 130 e 260mg CaCO3/L não apresentaram diferença significativa para o número de desovas totais por fêmea (p<0,05). Para o tratamento dureza 30mg CaCO3/L, houve maior mortalidade (menor longevidade). Assim, para controlar a proliferação dos microcrustáceos Moina micrura no tanque de decantação, a indústria deverá manter o pH do tanque de decantação próximo de 5,0, bem como dureza ao redor de 30mg CaCO3/L. / A problem encountered by the company CLE Brazil, situated on the north coast of Santa Catarina, was the presence of microcrustacean Moina micrura (Kurz, 1874) in the settling tank of effluent treatment system. In great density, this organism causes an increase in turbidity and a lower deposition of the flakes, establishing a concentration of settleable solids in suspension above the acceptable, under state law, in the effluent released by this company. In an attempt to solve the problem, our study evaluated the influence of pH and hardness on the inhibition of the life cycle of Moina micrura, using three variations of pH (5.0, 7.0, 9.0) and four variations of hardness (30, 65, 130, 260mg CaCO3/L), using ten repetitions with one individual each. Was analyzed the influence on the total organisms generated per female, on the number of spawning per female and the longevity for the different treatments. For the three variations of pH examined, there was no significant difference between treatments for total organisms generated per female and the number of spawning per female (p <0.05), however for the treatment pH = 5,0 there was higher mortality (shorter lifetime). The treatment hardness 30 mg CaCO3/L showed the lowest number of organisms produced per female and a smaller number of spawning per female (p <0.05); the treatments hardness 65 and 130 mg CaCO3/L were an intermediate value in the number of organisms produced per female and for treatment hardness 260mg CaCO3/L was the highest number of organisms produced per female. Treatments 65, 130 and 260mg CaCO3/L showed no significant difference for number of spawning per female (p < 0.05). For treatment hardness 30mg CaCO3/L there was higher mortality (shorter lifetime). To control the proliferation of microcrustaceans Moina micrura in the settling tank, the company must maintain the pH of the settling tank near of 5,0 and hardness around 30 mg CaCO3/L.
|
3 |
Avaliação das características físico-químicas e biológicas dos resíduos de tanques sépticos coletados por caminhões limpa-fossas na cidade de Tubarão-SCMachado Júnior, Antônio Rogério 24 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2008. / Made available in DSpace on 2012-10-24T05:58:47Z (GMT). No. of bitstreams: 1
271606.pdf: 1602219 bytes, checksum: b83bf73fe99aa0adeea4aa2fb87eb65e (MD5) / A disposição inadequada dos resíduos provenientes de tanques sépticos no município de Tubarão, no estado de Santa Catarina, tem causado vários danos ambientais não só à comunidade local, como também aos municípios vizinhos. Por este motivo, foi desenvolvido um estudo no qual foram avaliadas as características físico-químicas e biológicas de tais resíduos, buscando desta maneira avaliar o potencial de poluição e proporcionar conhecimento de informações primárias para alternativas de tratamento. Para tal finalidade, foram analisadas vinte e uma amostras de tanques sépticos das cinco companhias que realizam a aspiração destes rejeitos originados tanto em residências como em empreendimentos comerciais e industriais. Os parâmetros analisados foram: pH, DBO, DQO, sólidos totais, teores de nitrogênio e fósforo, óleos e graxas, coliformes, helmintos e metais como o cromo, cobre, manganês e zinco. Os resultados das análises mostraram-se compatíveis com os dados da literatura consultada referentes aos lodos de tanques sépticos, comprovando as características poluidoras destes rejeitos. Foram encontrados, por exemplo, valores médios de DBO na faixa de 3.500 mg/L, enquanto que a DQO média atingiu 19.600 mg/L. Para o nitrogênio total e para o ortofosfato, as médias foram de 114,84 mg/L e 70,12 mg/L, respectivamente. No caso do teor de óleos e graxas, a média situou-se em 521 mg/L. Para os metais analisados foi obtido uma média de 3,56 mg/L para o cromo, 5,67 mg/L para o manganês, 3,82 mg/L para o cobre e 3,44 mg/L para o zinco. Todos os parâmetros analisados ultrapassaram os valores limites para lançamento de efluentes estabelecidos tanto pela legislação de Santa Catarina como pelas leis federais. / The improper disposal of waste from septic tanks in the municipality of Tubarão, in Santa Catarina state, has caused several environmental damages not only to the local community, but also to neighboring counties. For this reason, this study was conducted to assess the physical-chemical and biological characteristics of these wastes, attempting to evaluate pollution strength and provide primary data for alternatives for treatment. For this purpose, twenty-one septic tanks samples were analyzed from five companies that perform domestic septage aspiration. The parameters analyzed were: pH, BOD, COD, total solids, levels of nitrogen and phosphorus, oils and greases, coliform, helminths and metals such as chromium, copper, manganese and zinc. Test results have proved compatible with domestic septage consulted literature pointing out its pollution strength. In the parameters analysis were found, for example, average values of BOD in the range of 3.500 mg/L, while the average COD reached 19.600 mg/L. For the total nitrogen and the orthophosphate, the average was 114,84 mg/L and 70,12 mg/L respectively. In the case of the content of oils and greases, the average stood at 521 mg/L. For metals analyzed was obtained an average of 3,56 mg/L for chromium, 5,67 mg/L for manganese, 3,82 mg/L for copper and 3,44 mg/L for zinc. All parameters examined exceeded effluents releasing limits established by the legislation both of Santa Catarina state and by federal laws.
|
4 |
Tratamento de lodo anaeróbio em wetlands construídos operados em alta taxa e com a recirculação de líquido percoladoKäfer, Silvana Cristina January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2015. / Made available in DSpace on 2015-11-10T03:09:38Z (GMT). No. of bitstreams: 1
335892.pdf: 2614464 bytes, checksum: e3f36fdce4f48c36ee61e16826889421 (MD5)
Previous issue date: 2015 / Com o objetivo de avaliar a eficiência dos wetlands construídos para o tratamento de lodo (WCL) foi realizada a operação e monitoramento de um experimento com dois wetlands piloto: um plantado com Cyperus papyrus (WP) e outro com Typha domingensis (WT). O tratamento foi baseado nos processos de desaguamento e estabilização de lodo proveniente de um tanque séptico. Os WCL foram operados com a aplicação de alta taxa de alimentação, intercalada com a recirculação do líquido percolado na própria unidade. A operação e monitoramento foram divididos em duas fases. Na Fase 1 (Outubro a Dezembro/2013) foram avaliadas as características físico-químicas do lodo do tanque séptico, do líquido percolado 1 (LP1) de cada wetland, bem como do líquido percolado 2 (proveniente da recirculação do LP1). Na Fase 2 (Janeiro a Novembro/2014), a alimentação dos WCL foi cessada e o lodo acumulado permaneceu em repouso durante onze meses. Amostras do lodo acumulado foram coletadas e foram analisados parâmetros físico-químicos, microbiológicos e seu potencial agronômico (este último ao final da Fase 2). De acordo com os resultados o teor de água do lodo foi reduzido, em média, 80% durante o desaguamento na Fase 1. Entre os parâmetros monitorados no LP1 destacam-se a remoção de 99% da carga de DQO e sólidos e de 96 e 97% da carga de amônia em WT e WP, respectivamente. Quanto à recirculação, WT e WP alcançaram, em média, 71 e 33% de remoção de água no LP1, e ainda tiveram um bom percentual de redução da carga poluidora, destacando-se 80% de remoção da carga de DQO e fósforo e 72% de remoção da carga de amônia em WT. Em WP houve remoção de 64% da carga de fósforo e de 31% na carga de amônia. Verificou-se que a maior redução das frações voláteis se deu durante o desaguamento do lodo (22% em média), enquanto nos onze meses de repouso houve redução de apenas 5 e 9% para WT e WP. As concentrações de compostos inorgânicos no lodo acumulado foram pequenas e estavam bem abaixo do limite máximo permitido pela Resolução CONAMA 375/2006. Houve, também, uma redução significativa quanto aos indicadores/patógenos, sendo que Salmonella e Adenovírus estavam ausentes em todas as amostras, e a concentração de E.coli foi < 10² NMP. g-1. O teor de matéria orgânica encontrado no lodo acumulado foi de 17%, superior ao que preconiza a Instrução Normativa do Ministério da Agricultura, Pecuária e Abastecimento Nº 25 de 2009. O teor de nitrogênio total encontrado no lodo acumulado no final do experimento foi quase o triplo do que o mínimo recomendado pela Instrução. Os teores de NPK do lodo acumulado foram de 1,83/1,25/0,02%. Os WCL associados às condições climáticas locais proporcionaram, portanto, um tratamento efetivo do lodo e de seus subprodutos.<br> / Abstract : In order to evaluate the efficiency of constructed wetlands for sludge treatment (WCL) two pilot wetlands were operated: one with Cyperus papyrus (WP) and the other with Typha domingensis (WT). The treatment was based on dewatering and stabilizing the sludge from a septic tank. The WCL were operated at high feeding rate, alternating with recirculation of the leachate liquid. The operation and monitoring of the system was divided in two phases. In Phase 1 (from October to December/2013) the physicochemical characteristics of the sludge from the septic tank, the leachate liquid (LP1) of each wetland, and the leachate liquid 2 (from the recirculation of LP1) were evaluated. In Phase 2 (from January to November/2014), the feeding of the WCL was stopped and the accumulated sludge was at a standstill for eleven months. Samples of the accumulated sludge were collected and analyzed for physical, chemical, and microbiological parameters as well as for the agronomic potential (the latter at the end of Phase 2). The results showed that the sludge water content was reduced by around 80% during the dewatering in Phase 1. Among the monitored parameters in LP1, the removal of 99% for COD and solids loads; and of 96 and 97% for ammonia load in WT and WP, respectively, can be highlighted. Regarding the recirculation, the average water removal in LP1 reached 71 and 33% for WT and WP, respectively. Furthermore, the systems were able to reduce the polluting load, with removal of 80% for COD and phosphorus, and of 72% for ammonia in WT. In WP 64% of the phosphorus load and 31% of the ammonia load were removed. It was found that further reduction of volatile fractions occurred during sludge dewatering (22% on average); while during the eleven months of standstill period the reduction was only of 5 and 9% for WT and WP, respectively. The concentrations of inorganic compounds in the accumulated sludge were small and below the maximum values permitted by the Resolution 375/2006 of CONAMA. A significant reduction of pathogens was also observed. Salmonella and Adenovirus were absent in all samples, and the concentration of E. coli was of <10² NMP.g-1. The organic matter content found in the accumulated sludge was of 17%. This value is higher than the limit permitted by the Ministry of Agriculture Normative Instruction, Livestock, and Food Supply nº 25/2009. The total nitrogen content found in the accumulated sludge at the end of the experiment was almost the triple than the minimum recommended by the aforementioned Instruction. NPK rates of the accumulated sludge were 1.83 / 1.25 / 0.02%. The WCL associated to local climatic conditions were, therefore, an effective treatment of sludge and its by-products.
|
5 |
Caracterização de lodo de tanque séptico e tratamento em filtros plantados com macrófitasFurtado, Daniel Ferreira de Castro January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2012 / Made available in DSpace on 2013-06-25T23:44:48Z (GMT). No. of bitstreams: 1
313539.pdf: 1267939 bytes, checksum: 6a4eecefaa6ca7411fb3ae0021066ec0 (MD5) / O tanque séptico é uma das tecnologias do saneamento descentralizado mais empregada para o tratamento de esgoto doméstico no Brasil, sendo utilizado por cerca de um quarto da população. Em sua operação é gerado em média um litro de lodo de esgoto por pessoa diariamente, o que remete à produção de um volume considerável deste resíduo em escala nacional. Devido suas características físico-químicas e biológicas, o lodo de tanque séptico necessita de processos de gestão eficientes, a fim de eliminar os seus impactos à saúde pública e ao ambiente, e de valorizar o seu potencial de uso agrícola. Os objetivos deste estudo foram caracterizar o lodo bruto de um tanque séptico, avaliar a eficiência de dois filtros plantados com macrófitas no tratamento de lodo de tanque séptico, denominados F1 e F2, com 4,3 m² de área superficial, 0,75 m de leito filtrante e diferentes espessuras de lodo acumulado, caracterizar o lodo acumulado formado na operação dos filtros e monitorar o seu processo de desaguamento e mineralização. A operação dos filtros foi realizada semanalmente durante os meses de maio a novembro de 2010, com taxa de alimentação de 125 kgST.m-².ano-1, fluxo em batelada e tempo de detenção hidráulica de 6 dias. O lodo séptico bruto e o líquido percolado gerado na operação dos filtros foram coletados e analisados semanalmente. Foram avaliados os parâmetros DQO, pH, alcalinidade, sólidos totais, sólidos totais voláteis, sólidos totais fixos, nitrogênio amoniacal, nitrito e nitrato, e fósforo ortofosfato. Os processos de desaguamento e mineralização do lodo acumulado na superfície de cada filtro foram monitorados durante os meses de outubro de 2010 a outubro de 2011 com a análise dos parâmetros ST e STV. Para a caracterização do lodo acumulado foram analisados os parâmetros pH, matéria orgânica, carbono orgânico total, nitrogênio total, fósforo total, potássio total, cálcio total, magnésio total, e os metais pesados, cobre, cádmio, chumbo, cromo, níquel e zinco. Os filtros apresentaram eficiências superiores a 87% na remoção da matéria orgânica e nutrientes. A espessura da camada de lodo acumulado não apresentou interferência na remoção dos parâmetros DQO, N-NH4+ e P-PO43-, contudo a camada de lodo mais espessa do filtro F1 pode ter influenciado para a melhor remoção dos sólidos totais observada neste filtro. O lodo acumulado dos filtros F1 e F2 apresentaram a maior concentração de ST, 51 e 49%, respectivamente, 83 dias após o último ciclo de alimentação dos filtros. O lodo acumulado nos filtros F1 e F2 apresentou teores de matéria orgânica na faixa de 22,5-39,0%, de nitrogênio total entre 1,1-2,0%, e conteúdos médios de 0,7% de fósforo total e 0,08% de potássio total. As concentrações de metais pesados no lodo acumulado de ambos os filtros estão dentro dos limites permitidos pela legislação nacional para uso agrícola.<br> / Abstract : The septic tank is a decentralized sanitation technology most often employed for the treatment of domestic sewage in Brazil, being used by about a quarter of the population. In its operation is generated on average one liter of sewage sludge per person daily, which leads to the production of a considerable amount of this waste on national scale. Due to physicochemical and biological characteristics, sludge from septic tank needs efficient management processes in order to eliminate their impacts to public health and the environment, and enhance their potential for agricultural reuse. The objectives of this study were to characterize the raw sludge from a septic tank, to evaluate the efficiency of two constructed wetlands in the treatment of septic sludge, called F1 and F2, with 4.3 m² surface area, 0.75 m filter bed and different thicknesses of accumulated sludge, to characterize accumulated sludge formed in the operation of the filters and to monitor the process of dewatering and mineralization. The operation of the filters was carried out weekly during the months of May to November 2010, with feed rate of 125 kgTS.m-².year-1, batch flow and hydraulic retention time of 6 days. The raw septic sludge and leachate generated in the operation of the filters were collected and analyzed weekly. Were evaluated the parameters COD, pH, alkalinity, total solids, total volatile solids, total fixed solids, ammonia, nitrite and nitrate, and orthophosphate. The process of dewatering and mineralization of accumulated sludge on the surface of each filter was monitored during the months of October 2010 to October 2011 with the analysis of the parameters TS and VS. For the characterization of accumulated sludge were analyzed pH, organic matter, total organic carbon, total nitrogen, total phosphorus, total potassium, total calcium, total magnesium, and heavy metals, copper, cadmium, lead, chromium, nickel and zinc. The filters had efficiencies greater than 87% in the removal of organic matter and nutrients. The thickness of the accumulated sludge not showed interference on removal of the parameters COD, NH4+-N and PO43--P, however the thickest layer of accumulated sludge in the filter F1 may have influenced for better removal of total solids found in this filter. The accumulated sludge in the filters F1 and F2 showed the highest concentration of TS, 51 and 49%, respectively, 83 days after the last feeding cycle of the filters. The accumulated sludge in the filters F1 and F2 showed organic matter levels in the range of 22.5-39.0%, total nitrogen between 1.1-2.0%, and average content of 0.7% total phosphorus and 0.08% potassium total. The concentrations of heavy metals in the accumulated sludge of both filters are within the limits allowed by national legislation for agricultural reuse.
|
6 |
Desaguamento de lodo de tanque séptico em filtros plantados com macrófitasSuntti, Carla 25 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pos-Graduação em Engenharia Ambiental, Florianópolis, 2010 / Made available in DSpace on 2012-10-25T01:34:00Z (GMT). No. of bitstreams: 1
279598.pdf: 1848177 bytes, checksum: 603f3f62b11fb27d7c6fa2b4edb1f103 (MD5) / Entre os sistemas individuais de tratamento de esgoto doméstico, o tanque séptico é o mais representativo, utilizado por 22% da população brasileira. Os tanques sépticos são projetados para reter e acumular lodo e escuma durante um determinado intervalo de tempo, sendo indispensável a limpeza periódica dos mesmos. No entanto, o lodo precisa de tratamento antes de sua disposição final no ambiente, uma vez que nele se concentram nutrientes, matéria orgânica, metais pesados e organismos patogênicos. Com o objetivo de avaliar o potencial do filtro plantado com macrófitas para o desaguamento de lodo de tanque séptico foram construídos dois filtros pilotos aplicando-se duas taxas distintas em termos de sólidos totais (F1 - 250 e F2 - 125 kgST.m-2.ano-1). Os filtros pilotos eram idênticos, com 4,3 m2 de área superficial, 0,75 m de meio filtrante e plantados com Zizaniopsis bonariensis. O trabalho experimental se desenvolveu em três fases: Fase I - alimentação dos filtros com esgoto durante 75 dias para amadurecimento do leito; Fase II - alimentação com lodo durante um mês para adaptação das macrófitas e Fase III com a taxa nominal estipulada inicialmente, por um período de 126 dias. Os resultados obtidos revelaram que o F2 apresentou melhor desempenho em relação ao F1 obtendo eficiência média de remoção de 96% sólidos totais, 99% demanda química de oxigênio, 99,9% sólidos suspensos e 72% de nitrogênio amoniacal, com concentrações efluentes de 472, 85, 18 e 10,7 mg.L-1, respectivamente. O F2 também apresentou maior concentração de sólidos totais no lodo acumulado no leito (33%) e por consequência, menor umidade (67%), enquanto o lodo acumulado no F1 a concentração de sólidos totais foi de 24% e a umidade foi de 76%. As concentrações de sólidos totais atingidas no lodo acumulado no filtro permitiram classificá-lo como torta semi-sólida. Em relação às macrófitas, as Fases I e II mostraram-se importantes para adaptação da espécie Z. bonariensi nos filtros. Com alimentação dos filtros com lodo, além de aumentar a biomassa das macrófitas foi verificado maior concentração de nitrogênio no tecido vegetal das mesmas, obtendo uma assimilação de 4% de nitrogênio no F1 e 6% no F2. As macrófitas foram importantes no tratamento do lodo pois, a elevada densidade destas no leito auxiliaram as perdas de água do lodo, principalmente pelo processo de evapotranspiração. Com base nestes resultados, e por meio das análises estatísticas pôde-se afirmar que o F2, que recebeu a menor taxa de lodo, apresentou um melhor desempenho no processo de desaguamento do lodo de tanque séptico. Desta forma, pode-se concluir que os filtros plantados com macrófitas, como sistema natural de tratamento de lodo apresentaram bom desempenho no desaguamento do mesmo, constituindo-se em uma tecnologia simples do ponto de vista operacional, com baixo consumo energético, não necessitando a adição de produtos químicos, podendo-se adequar para pequenas comunidades.
|
7 |
Avaliação do desempenho da modificação de um sistema de tratamento de esgoto composto por tanque séptico e filtro anaeróbio por um modelo de aeração compartimentada / Performance evaluation of the modification of a sewage treatment system consisting of septic tank and anaerobic filter for a model compartimentalized aerationFrança, Josue Tadeu Leite 20 August 2018 (has links)
Orientador: Ronaldo Stefanutti / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-20T00:18:11Z (GMT). No. of bitstreams: 1
Franca_JosueTadeuLeite_D.pdf: 5624209 bytes, checksum: 5cf73703ce197d3837470af4dd88e602 (MD5)
Previous issue date: 2012 / Resumo: Este trabalho tem como objetivo avaliar o desempenho da modificação concernente a um processo de tratamento "tanque séptico seguido de filtro anaeróbio", no Distrito Bom Retiro, município de Angatuba, região sudoeste do Estado de São Paulo, por um modelo aerado, com aproveitamento integral das unidades existentes após pequenas adequações, visando atender a legislação e com baixo nível de operação. O sistema foi baseado em alguns parâmetros utilizados em lagoas aeradas e parcialmente aeradas. A remoção do lodo para a proposta é anual ou quando o sistema atingir os limites dos parâmetros de controle operacional: DBO efluente ? 60 mg O2 L-1 ou eficiência de remoção dos SST ? 80%. Após um ano de operação da proposta parcialmente concluída (sem tratamento preliminar), apesar de não atingir os limites máximos estabelecidos foram realizadas a quantificação e remoção do lodo gerado. O sistema de desaguamento foi realizado em uma série de "BAGs" verticais de polipropileno reutilizáveis por até 20 vezes, com capacidade para 2m³. Após as adequações, os resultados na segunda etapa do experimento com relação à DBO afluente e efluente, sólidos em suspensão total efluente (SST), residual de oxigênio dissolvido na saída do tanque de polimento, densidade de potência utilizada, custo de energia per capta (kWh ano-1) e custo de implantação per capta foram: DBO afluente e efluente teve como média e desvio padrão 674 ± 137 mg O2 L-1 e 22 ± 5 mg O2 L-1, respectivamente. A média aparada com relação ao residual de oxigênio dissolvido foi de 3,6 ± 1,2 mg L-1, a densidade de potência 42 W m-3, o consumo de energia foi de 56 kWh hab-1 ano-1 e o custo de implantação per capita foi de R$ 140,00. A proposta visa a adequação dos sistemas (tanque séptico + filtro anaeróbio) e implantação em pequenas comunidades, sem sistemas de tratamento de esgotos / Abstract: This work aims to evaluate the performance concerning the modification of the a treatment process "septic tank followed by anaerobic filter", in Bom Retiro district, municipality of Angatuba, and southwest of São Paulo, by aerated model with full use of existing units after minor adjustments, to meet the rules environmental and low level of operation. The system is based on some parameters used in aerated lagoons and partly aerated lagoons. The sludge removal is proposed for the year or when the system reaches the limits of the parameters of operational control: ? 60 mg O2 L-1 BOD effluent and TSS removal efficiency of ? 80%. After a year of operation of the proposed partially completed (without pre-treatment) did not reach the ceilings was conducted to quantify and removal of sludge generated. The dewatering system was conducted in a number of "BAGs" vertical polypropylene reusable for up to 20 times, with a capacity of 2 m³. After the adjustments results in the second stage of the experiment with respect to the influent and effluent BOD, total suspended solids effluent (TSS), residual dissolved oxygen in the tank outlet polishing, power density used, energy cost per capita (kWh year -1) and cost of deployment per capita were: influent and effluent BOD was mean and standard deviation 674 ± 137 mg O2 L-1 and 22 ± 5 mg O2 L-1, respectively. The mean residual trimmed with respect to dissolved oxygen was 3.6 ± 1,2 mg L-1, the power density 42 W m-3, the power consumption was 56 kWh. hab-1 year -1 and implementation cost per capita of R$ 140.00. The proposal aims adequacy of systems (septic tank + anaerobic filter) and deployment in small communities without sewage treatment systems / Doutorado / Saneamento e Ambiente / Doutor em Engenharia Civil
|
8 |
Utilização de reator de leito fluidizado trifásico aeróbio em sistema de tratamento combinado de águas residuáriasCampos, Rosane Hein de January 2001 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Ambiental / Made available in DSpace on 2012-10-18T11:51:02Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-26T00:06:49Z : No. of bitstreams: 1
182904.pdf: 26947699 bytes, checksum: 188065ff59b00e574141746a1e317ff0 (MD5) / Neste trabalho, foram desenvolvidos estudos em um sistema de tratamento combinando reator anaeróbio (tanque séptico) com reator aeróbio (leito fluidizado trifásico), tendo como objetivo avaliar o comportamento do reator aeróbio no tratamento de esgoto sanitário e do restaurante universitário (RU), da UFSC. Utilizou-se um reator de leito fluidizado trifásico aeróbio com volume de 62,80 L e foram testados dois tipos de materiais suportes, o poliestireno e o PVC, com densidades de 1065 kg/m3 e 1329 kg/m3 e diâmetro médio de 2,7 mm e 4,02 mm, respectivamente. Trabalhou-se em duas etapas. Na primeira etapa, foram realizados estudos hidrodinâmicos do reator e o tratamento biológico, com efluente doméstico do RU, utilizando o poliestireno como material suporte. A segunda etapa consistiu de estudos hidrodinâmicos do reator e o tratamento biológico, com efluentes domésticos do RU e esgoto urbano, utilizando o PVC como material suporte. O acompanhamento analítico do controle do processo foi efetuado pelos seguintes parâmetros: pH, temperatura, oxigênio dissolvido, sólidos suspensos, produção de lodo, polissacarídeos (PS) aderidos ao suporte e suspensos no efluente e proteínas (PN) aderidas ao suporte e suspensas no efluente. Os resultados mostraram que o poliestireno não se apresentou como uma boa alternativa para o tratamento biológico, para as condições operacionais utilizadas. Com a utilização do PVC, obtiveram-se eficiências médias de remoção de DQO filtrada, foram de 36% e 78% para cargas orgânicas volumétricas aplicadas (COVap.) de 17 kgDQO/m3d e 36 kgDQO/m3d, respectivamente. Observações feitas através do microscópio eletrônico de varredura mostraram um biofilme fino, com colonização no interior da matriz polissacarídica. A relação PS/PN aderida (entre 2,7 e 16,7) indicou a existência de um biofilme mais coeso e como conseqüência baixa produção específica de lodo (1,45 mg de biomassa/mg de DQO removida e 0,19 mg de biomassa/mg de DQO removida). O acompanhamento através do microscópio ótico revelou as condições microbiológicas do efluente. Observaram-se pequenos flocos ricos em Zoogleas, Zooflagelados, Ciliados fixos (Epystilis, Vorticellas) e livres (Uronemas, Metopus e outros), bactérias filamentosas e bactérias livres em suspensão. O coeficiente de desprendimento (bs), mostrou-se elevado, indicando um grande desprendimento do biofilme em meio líquido, devido ao cisalhamento pela passagem do líquido no reator, influenciando na concentração de sólidos suspensos na saída do reator. A combinação de reatores anaeróbios e reator de leito fluidizado trifásico aeróbio apresenta-se como uma alternativa interessante pela eficiência de remoção da matéria carbonácea, aplicando-se elevadas cargas volumétricas orgânicas (>10kgDQO/m3.dia).
|