• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • Tagged with
  • 9
  • 9
  • 9
  • 8
  • 8
  • 5
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise do enxofre corrosivo em óleo mineral isolante e remoção do dibenzil dissulfeto com nanotubos de carbono baseados em matriz metálica

SARAIVA, Augusto Cesar Fonseca 07 May 2012 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2014-01-13T19:07:46Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_AnaliseEnxofreCorrosivo.pdf: 5261345 bytes, checksum: d394934b8edcf92029d079a04f821905 (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2014-01-14T16:03:22Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_AnaliseEnxofreCorrosivo.pdf: 5261345 bytes, checksum: d394934b8edcf92029d079a04f821905 (MD5) / Made available in DSpace on 2014-01-14T16:03:22Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_AnaliseEnxofreCorrosivo.pdf: 5261345 bytes, checksum: d394934b8edcf92029d079a04f821905 (MD5) Previous issue date: 2012 / Falhas inesperadas em transformadores levaram a identificação da formação de sulfeto de cobre, depositado sobre os condutores, avaliando-se da presença qualitativa de enxofre corrosivo resultando na alteração da norma brasileira ABNT NBR 10505, que avalia a presença de enxofre corrosivo em óleo mineral, alterando-se o tempo e a temperatura de ensaio para 150 °C por 48 horas. Realizando-se a especiação química de compostos organosulfurados via cromatografia gasosa acoplada a espectrometria de massas, onde foram encontrados 13 compostos sulfurados no óleo Nynas e 9 compostos no óleo da Petrobras, sendo o dibenzil dissulfeto (DBDS) o de maior concentração, encontrado apenas no óleo Nynas. Para realizar a determinação da presença do DBDS em óleo mineral isolante foi desenvolvido um método através de cromatografia gasosa acoplada a espectrometria de massas, e por este método foi possível quantificar o teor de DBDS em amostras de OMI oriundas de transformadores de potência. Foi avaliado o processo de passivação do cobre por benzotriazol e tolutriazol, utilizados como aditivos anticorrosivos no núcleo dos equipamentos elétricos, verificando-se que o efeito da adição agente de passivação torna-se ineficaz com o passar do tempo. A solução para a remoção de DBDS em óleo mineral foi a utilização de nanotubo de carbono baseado em matriz metálica (NTC/Al) como agente de remoção do DBDS. Verificou-se que o agente de adsorção foi capaz de efetuar a remoção total do DBDS do OMI até um volume de 4000 mL de óleo contaminado com DBDS. / Unexpected failures in transformers led to the identification of copper sulphide formation, deposited on the conductors. The qualitative presence evaluation of corrosive sulfur in insulating mineral oil, led to a change in the Brazilian standards ABNT NBR 10505, which assesses the presence of corrosive sulfur in mineral oil, change in the time and test temperature to 150 °C / 48 hours. Performing the chemical speciation of organosulfur compounds (by gas chromatography coupled to mass spectrometry), were found 13 compounds in the Nynas oil and 9 compounds in the Petrobras oil. DBDS, which was found only in the Nynas oil, and it was the compound with the highest concentration. To perform the determination of the presence of DBDS in insulating mineral oil, a method by gas chromatography coupled to mass spectrometry was developed, and it was possible to quantify the amount of DBDS in insulating mineral oil samples derived from the power transformer. The passivation process by tolutriazol and benzotriazol, used as anticorrosive additives in the core of electrical equipament, was evaluated; after a while the effect of the addition of passivating agent becomes ineffective with time. The solution for the remotionl of DBDS from mineral oil was realized by using carbon nanotube reinforced by metallic matrix as agent to remove the DBDS. It was found that the adsorption agent was able to realize the complete DBDS remotion from insulating mineral oil up to a volume of 4000 mL (oil contaminated with DBD).
2

Espumas poliuretânicas derivadas de óleo de mamona utilizadas na adsorção de bifenilas policloradas (PCBs) presentes em óleo mineral isolante / Polyurethane foam derived from castor oil used in adsorption polychlorinated biphenyls (PCBs) present in mineral insulating oil

Marcio Antonio Ferreira Camargo 24 November 2010 (has links)
Os PCBs, do inglês Polychlorinated Biphenyls (bifenilas policloradas), é o nome genérico dado à classe de compostos organoclorados resultante da reação do grupo bifenila com cloro anidro na presença de catalisador. São tóxicos, persistentes, bioacumulativos e representam o risco de provocar efeitos nocivos à saúde humana e ao meio ambiente. Grandes quantidades de PCBs foram produzidos em vários países entre 1927 e 1977. Nos Estados Unidos a proibição ocorreu em 1977. Utilizados como fluidos dielétricos em transformadores elétricos e capacitores em todo o mundo, comercialmente conhecidos como Ascarel, dentre outras denominações, tais como Aroclor, Pyralene, Clorophen, Inerteen, Asbestol e Kneclor. Devido à alta toxicidade, a produção e comercialização dos PCBs foram proibidas no mundo todo a partir de 1980. No Brasil, transformadores que tiveram o óleo mineral isolante, contaminado por PCBs, estando em uso ou em armazenamento, segundo os critérios da Norma ABNT NBR 13882, a destinação final do óleo isolante deverá ser feita por incineração e ou descontaminação a valores inferiores a 50mg/kg. Neste trabalho realizado no Instituto de Química de São Carlos - Universidade de São Paulo, desenvolveu-se um procedimento para a descontaminação de óleo contaminado com valor conhecido acima de 50mg/kg, por percolação em coluna contendo espuma de poliuretano derivada de óleo de mamona, produzida pelo Laboratório de Química Analítica e Tecnologia de Polímeros (GQATP), obtendo-se uma redução de 55% dos níveis de PCBs em óleo contaminado. As espumas foram funcionalizadas com tiodiglicol e polissulfeto de amônio, obtendo-se respectivamente 24% e 11% de redução dos níveis de PCBs em óleo contaminado. Observou-se que a espuma de poliuretano produzida pelo GQATP, funciona como um adsorvente eficaz na remoção de PCBs, e que a utilização de n-hexano na dessorção da espuma, permite remover praticamente todos os PCBs adsorvidos. Portanto, esses tipos de espumas podem servir como adsorventes altamente eficazes na remoção dos PCBs presentes nos óleos minerais isolantes e, portanto, contribuir significativamente para a proteção do meio ambiente. / PCBs, (polychlorinated biphenyls), is the generic name given to the class of organochlorine compounds resulting from the reaction of the biphenyl group with anhydrous chlorine in the presence of catalyst. They are toxic, persistent, bioaccumulative and pose the risk of causing harm to human health and the environment. Large quantities of PCBs were produced in several countries between 1927 and 1977. In the United States the prohibition occurred in 1977. Used as dielectric fluids in electrical transformers and capacitors in the world, commercially known as Ascarel, among other names such as Aroclor, Pyralene, Clorophen, Inerteen, and Asbestol Kneclor. Due to high toxicity, production and marketing of PCBs have been banned worldwide since 1980. In Brazil, transformers that had insulating mineral oil, contaminated with PCBs, while in use or in storage, according to the criteria of the Standard NBR 13,882, the final destination of insulating oil should be by incineration or decontamination and the values below 50mg/kg. In a previous work carried out at the Chemistry Institute of Sao Carlos - University of Sao Paulo, a procedure was developed for the decontamination of oil contaminated with known value above 50 mg / kg of percolation column containing polyurethane foam derived from castor oil produced Laboratory of Analytical Chemistry and Technology of Polymers (GQATP), resulting in a 55% reduction in the levels of PCBs in contaminated oil. Foams were functionalized with thiodiglycol and Ammonium polysulfide, yielding respectively 24% and 11% reduction in the levels of PCBs in contaminated oil. It was observed that the polyurethane foam produced by GQATP function as an effective adsorbent for removal of PCBs, and that the use of n-hexane desorption of the foam allows to remove virtually all PCBs adsorbed. So these types of foam can serve as highly efficient adsorbents for the removal of PCBs present in the insulating mineral oil, and thus contribute significantly to environmental protection.
3

Espumas poliuretânicas derivadas de óleo de mamona utilizadas na adsorção de bifenilas policloradas (PCBs) presentes em óleo mineral isolante / Polyurethane foam derived from castor oil used in adsorption polychlorinated biphenyls (PCBs) present in mineral insulating oil

Camargo, Marcio Antonio Ferreira 24 November 2010 (has links)
Os PCBs, do inglês Polychlorinated Biphenyls (bifenilas policloradas), é o nome genérico dado à classe de compostos organoclorados resultante da reação do grupo bifenila com cloro anidro na presença de catalisador. São tóxicos, persistentes, bioacumulativos e representam o risco de provocar efeitos nocivos à saúde humana e ao meio ambiente. Grandes quantidades de PCBs foram produzidos em vários países entre 1927 e 1977. Nos Estados Unidos a proibição ocorreu em 1977. Utilizados como fluidos dielétricos em transformadores elétricos e capacitores em todo o mundo, comercialmente conhecidos como Ascarel, dentre outras denominações, tais como Aroclor, Pyralene, Clorophen, Inerteen, Asbestol e Kneclor. Devido à alta toxicidade, a produção e comercialização dos PCBs foram proibidas no mundo todo a partir de 1980. No Brasil, transformadores que tiveram o óleo mineral isolante, contaminado por PCBs, estando em uso ou em armazenamento, segundo os critérios da Norma ABNT NBR 13882, a destinação final do óleo isolante deverá ser feita por incineração e ou descontaminação a valores inferiores a 50mg/kg. Neste trabalho realizado no Instituto de Química de São Carlos - Universidade de São Paulo, desenvolveu-se um procedimento para a descontaminação de óleo contaminado com valor conhecido acima de 50mg/kg, por percolação em coluna contendo espuma de poliuretano derivada de óleo de mamona, produzida pelo Laboratório de Química Analítica e Tecnologia de Polímeros (GQATP), obtendo-se uma redução de 55% dos níveis de PCBs em óleo contaminado. As espumas foram funcionalizadas com tiodiglicol e polissulfeto de amônio, obtendo-se respectivamente 24% e 11% de redução dos níveis de PCBs em óleo contaminado. Observou-se que a espuma de poliuretano produzida pelo GQATP, funciona como um adsorvente eficaz na remoção de PCBs, e que a utilização de n-hexano na dessorção da espuma, permite remover praticamente todos os PCBs adsorvidos. Portanto, esses tipos de espumas podem servir como adsorventes altamente eficazes na remoção dos PCBs presentes nos óleos minerais isolantes e, portanto, contribuir significativamente para a proteção do meio ambiente. / PCBs, (polychlorinated biphenyls), is the generic name given to the class of organochlorine compounds resulting from the reaction of the biphenyl group with anhydrous chlorine in the presence of catalyst. They are toxic, persistent, bioaccumulative and pose the risk of causing harm to human health and the environment. Large quantities of PCBs were produced in several countries between 1927 and 1977. In the United States the prohibition occurred in 1977. Used as dielectric fluids in electrical transformers and capacitors in the world, commercially known as Ascarel, among other names such as Aroclor, Pyralene, Clorophen, Inerteen, and Asbestol Kneclor. Due to high toxicity, production and marketing of PCBs have been banned worldwide since 1980. In Brazil, transformers that had insulating mineral oil, contaminated with PCBs, while in use or in storage, according to the criteria of the Standard NBR 13,882, the final destination of insulating oil should be by incineration or decontamination and the values below 50mg/kg. In a previous work carried out at the Chemistry Institute of Sao Carlos - University of Sao Paulo, a procedure was developed for the decontamination of oil contaminated with known value above 50 mg / kg of percolation column containing polyurethane foam derived from castor oil produced Laboratory of Analytical Chemistry and Technology of Polymers (GQATP), resulting in a 55% reduction in the levels of PCBs in contaminated oil. Foams were functionalized with thiodiglycol and Ammonium polysulfide, yielding respectively 24% and 11% reduction in the levels of PCBs in contaminated oil. It was observed that the polyurethane foam produced by GQATP function as an effective adsorbent for removal of PCBs, and that the use of n-hexane desorption of the foam allows to remove virtually all PCBs adsorbed. So these types of foam can serve as highly efficient adsorbents for the removal of PCBs present in the insulating mineral oil, and thus contribute significantly to environmental protection.
4

Metodologia acústica para análise de óleo de transformador por sensores piezoelétricos / Acoustic methodology for oil transformers analysis by piezoelectric sensors

Palitó, Thamyres Tâmulla Cavalcante 08 May 2019 (has links)
Os transformadores são equipamentos fundamentais para o sistema elétrico e o acompanhamento regular de suas condições de operação é muito importante para que se reduzam custos associados ao seu ciclo de vida, bem como para que se possa garantir a sua confiabilidade e a sua durabilidade. As falhas elétricas ocorrem, muitas vezes, motivadas pela degradação do sistema isolante e consequentemente danificam o equipamento. O óleo é um dos componentes isolantes que se deteriora com facilidade devido ação de falhas ou variação de temperatura e umidade. O acompanhamento e a manutenção da qualidade do óleo isolante são etapas essenciais para proporcionar uma operação confiável dos equipamentos elétricos garantindo a confiabilidade do fornecimento de energia. Um dos parâmetros que pode ser monitorado no óleo é a água, pois esta reduz drasticamente a rigidez elétrica do dielétrico. Uma revisão na literatura relata alguns procedimentos de diagnósticos disponíveis para avaliar a condição do óleo de transformadores, tais como as análises físico química e a análise de gases dissolvidos (DGA). Pesquisas recentes revelam um tópico ressaltado que consiste na utilização de sensores acústicos para caracterização de líquidos, uma vez que essa análise possui a vantagem de ser não destrutiva, com possibilidade de aplicações não invasivas e em transformadores em operação. Neste contexto, esta tese propõem uma metodologia acústica para contribuir na detecção de umidade no óleo mineral isolante utilizando sensores piezoelétricos. A metodologia consiste na utilização de sensores para emitir e recepcionar os sinais transmitidos através de amostras de óleos de transformadores. Os experimentos foram realizados na faixa de MHz, utilizando transdutores comerciais e na faixa de kHz, utilizando um transdutor piezoelétrico desenvolvido pelo Grupo de Alta Tensão e materiais da USP de São Carlos. Medidas da amplitude do sinal são correlacionadas com o teor de água contido nas amostras de óleos. Os resultados revelam que é possível diagnosticar se as amostras de óleo estão aptas ou não para uso em transformadores. Em alguns casos é possível distinguir as quatro classes das amostras de óleo mineral isolante testadas: óleo novo (virgem), óleo regenerado, óleo sujo e óleo queimado. A metodologia proposta, além de ser inédita, se mostra promissora para auxiliar no diagnóstico de amostras de óleo mineral isolante em campo. / Transformers are fundamental equipment in electrical power system and constant monitoring their operating conditions is very important to reduce the costs associated with their life cycle, as well as to guarantee their reliability and durability. One of the main cause of electrical failures in power transformers is the degradation of the power transformer insulation system, which can cause permanent damages. A crucial element in their insulation system is oil used to insulate parts, but also to cool the equipment. Therefore monitor and maintain the insulating oil are essential steps to provide a reliable operation of the electrical equipment guaranteeing the reliability of the power supply. A review in the literature reports a wide variety of diagnostic procedures available to assess the condition of transformer oil, such as physical chemical analysis and dissolved gas (DGA) analysis. Recent research reveals a highlighted topic that consists of the use of acoustic sensors for characterizing liquids, since the acoustic analysis presents the characteristic of being non-destructive with possibility of non-invasive and application during transformer operation i.e. in line. In this context, this thesis proposes an acoustic methodology for the analysis of mineral insulating oil using piezoelectric sensors. The methodology consists of the use of sensors to emit and receive signals transmitted through oil transformer samples. The experiments were carried out in the MHz band, using commercial transducers and in the kHz band, using a piezoelectric transducer developed by the High Voltage and Materials Group from USP of São Carlos. Measurements of signal amplitude are correlated with the water content contained in the oil samples. The results show that it is possible to diagnose whether or not the oil samples are suitable for use in transformers. In some cases it is possible to distinguish the four classes of tested mineral oil samples. The proposed methodology is promising for the diagnosis of mineral insulation oil samples in the field.
5

Modelagem e simulação da decomposição térmica do óleo mineral isolante aplicadas à classificação de defeitos em transformadores de potência / Modeling and simulation of the mineral insulating oil thermal decomposition applied to faults classification in power transformers

Vinicius Gabriel Macedo Cruz 20 February 2015 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / A análise de gases dissolvidos tem sido aplicada há décadas como a principal técnica de manutenção preditiva para diagnosticar defeitos incipientes em transformadores de potência, tendo em vista que a decomposição do óleo mineral isolante produz gases que permanecem dissolvidos na fase líquida. Entretanto, apesar da importância desta técnica, os métodos de diagnóstico mais conhecidos são baseados em constatações de modelos termodinâmicos e composicionais simplificados para a decomposição térmica do óleo mineral isolante, em conjunto com dados empíricos. Os resultados de simulação obtidos a partir desses modelos não reproduzem satisfatoriamente os dados empíricos. Este trabalho propõe um modelo termodinâmico flexível aprimorado para mimetizar o efeito da cinética de formação de sólidos como restrição ao equilíbrio e seleciona, entre quatro modelos composicionais, aquele que apresenta o melhor desempenho na simulação da decomposição térmica do óleo mineral isolante. Os resultados de simulação obtidos a partir do modelo proposto apresentaram uma melhor adequação a dados empíricos do que aqueles obtidos a partir dos modelos clássicos. O modelo propostofoi, ainda, aplicado ao desenvolvimento de um método de diagnóstico com base fenomenológica.Os desempenhos desta nova proposta fenomenológica e de métodos clássicos de diagnóstico por análise de gases dissolvidos foram comparados e discutidos; o método proposto alcançou desempenho superior a vários métodos usualmente empregados nessa área do conhecimento. E, ainda, um procedimento geral para a aplicação do novo método de diagnóstico é descrito / The dissolved gas analysis has been applied for decades as the main predictive maintenance technique for diagnosing incipient faults in power transformers since the decomposition of the mineral insulating oil produces gases that remain dissolved in the liquid phase. Nevertheless, the most known diagnostic methods are based on findings of simplified thermodynamic and compositional models for the thermal decomposition of mineral insulating oil, in addition to empirical data. The simulations results obtained from these models do not satisfactorily reproduce the empirical data. This work proposes a flexible thermodynamic model enhanced to mimic the kinetic effect of solid formation as a restriction to equilibrium and selects, among four compositional models, the one offering the best performance on the simulation of the thermal decomposition of mineral insulating oil. The simulation results obtained from the proposed model showed better adequacy to reported data than the results obtained from the classical models. The proposed model was also applied in the development of a diagnostic method with a phenomenological basis. The performances of this new phenomenological proposition and of classical dissolved gas analysis diagnostic methods are compared and discussed; the proposed method achieved a performance superior to several methods usually employed in this area of knowledge.Also, a general procedure for the application of the new diagnostic method is described
6

Modelagem e simulação da decomposição térmica do óleo mineral isolante aplicadas à classificação de defeitos em transformadores de potência / Modeling and simulation of the mineral insulating oil thermal decomposition applied to faults classification in power transformers

Vinicius Gabriel Macedo Cruz 20 February 2015 (has links)
Fundação de Amparo à Pesquisa do Estado do Rio de Janeiro / A análise de gases dissolvidos tem sido aplicada há décadas como a principal técnica de manutenção preditiva para diagnosticar defeitos incipientes em transformadores de potência, tendo em vista que a decomposição do óleo mineral isolante produz gases que permanecem dissolvidos na fase líquida. Entretanto, apesar da importância desta técnica, os métodos de diagnóstico mais conhecidos são baseados em constatações de modelos termodinâmicos e composicionais simplificados para a decomposição térmica do óleo mineral isolante, em conjunto com dados empíricos. Os resultados de simulação obtidos a partir desses modelos não reproduzem satisfatoriamente os dados empíricos. Este trabalho propõe um modelo termodinâmico flexível aprimorado para mimetizar o efeito da cinética de formação de sólidos como restrição ao equilíbrio e seleciona, entre quatro modelos composicionais, aquele que apresenta o melhor desempenho na simulação da decomposição térmica do óleo mineral isolante. Os resultados de simulação obtidos a partir do modelo proposto apresentaram uma melhor adequação a dados empíricos do que aqueles obtidos a partir dos modelos clássicos. O modelo propostofoi, ainda, aplicado ao desenvolvimento de um método de diagnóstico com base fenomenológica.Os desempenhos desta nova proposta fenomenológica e de métodos clássicos de diagnóstico por análise de gases dissolvidos foram comparados e discutidos; o método proposto alcançou desempenho superior a vários métodos usualmente empregados nessa área do conhecimento. E, ainda, um procedimento geral para a aplicação do novo método de diagnóstico é descrito / The dissolved gas analysis has been applied for decades as the main predictive maintenance technique for diagnosing incipient faults in power transformers since the decomposition of the mineral insulating oil produces gases that remain dissolved in the liquid phase. Nevertheless, the most known diagnostic methods are based on findings of simplified thermodynamic and compositional models for the thermal decomposition of mineral insulating oil, in addition to empirical data. The simulations results obtained from these models do not satisfactorily reproduce the empirical data. This work proposes a flexible thermodynamic model enhanced to mimic the kinetic effect of solid formation as a restriction to equilibrium and selects, among four compositional models, the one offering the best performance on the simulation of the thermal decomposition of mineral insulating oil. The simulation results obtained from the proposed model showed better adequacy to reported data than the results obtained from the classical models. The proposed model was also applied in the development of a diagnostic method with a phenomenological basis. The performances of this new phenomenological proposition and of classical dissolved gas analysis diagnostic methods are compared and discussed; the proposed method achieved a performance superior to several methods usually employed in this area of knowledge.Also, a general procedure for the application of the new diagnostic method is described
7

Diagnóstico de falhas em transformadores de potência utilizando sensores de gás semicondutores

Silva, Lucas Tenório de Souza 30 August 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This dissertation introduces the study of the use of tin dioxide gas sensor array applied to fault detection in power transformers, through dissolved gas-in-oil. The aim of this research is to analyze the data obtained from gas sensors array, using pattern recognition techniques, and thus to determine if the use of gas sensor array allows the identification of faults. In order to facilitate the understanding of this research, the document was organized covering the following topics: power transformers, mineral insulating oil, analysis and interpretation of dissolved gás-in-oil, tin dioxide sensors and data acquisition instrument, techniques of pattern recognition and methodology for generating faults. In the end of this dissertation, the data from the sensor array are analyzed, in order to achieve the objective of verifying its application in the identification of faults. / Esta dissertação introduz o estudo do uso de uma matriz de sensores de gases de dióxido de estanho na detecção de falhas em transformadores de potência, através dos gases dissolvidos no óleo. O objetivo desta pesquisa é analisar os dados obtidos pelos sensores de gás, utilizando algumas técnicas de reconhecimento de padrão, e desta forma, verificar se o uso da matriz de sensores possibilita a identificação das falhas. Com o intuito de facilitar o entendimento da pesquisa, o presente documento foi organizado abordando os seguintes tópicos: transformadores de potência; óleo mineral isolante; análise e interpretação dos gases dissolvidos em óleo; sensores de dióxido de estanho e instrumento de aquisição de dados; técnicas de reconhecimento de padrões; e metodologia de geração de falhas. Ao final desta dissertação, os dados da matriz de sensores são analisados, a fim de atingir o objetivo de verificar sua aplicação na identificação das falhas.
8

Modelagem fuzzy da concentração dos gases dissolvidos em óleo mineral isolante de transformadores baseada em resultados de ensaios físico-químicos / Fuzzy approaching of the concentration of dissolved gases in insulating mineral oil based on physical-chemical results

Campi, Rodrigo Luz 19 February 2014 (has links)
O objetivo desse trabalho foi de fazer a modelagem por meio de sistemas de inferência fuzzy da concentração dos gases dissolvidos em óleo mineral isolante à partir dos resultados de ensaios físico-químicos. Dessa forma, objetivou-se estender as técnicas de identificação de falhas em transformadores por meio da análise dos ensaios físico-químicos do óleo isolante. Para tanto adotou-se um mapeamento entre os dados de ensaios físico-químicos e de cromatografia gasosa feito por meio de sistemas de inferência fuzzy. Assim, por meio de resultados de ensaios físico-químicos, como cor, densidade, unidade, entre outro, tem-se uma estimativa da concentração dos gases dissolvidos no óleo mineral isolante do transformador. Assim, torna-se possível empregar técnicas de identificação de falhas baseadas na concentração dos gases dissolvidos, mas, valendo-se dos dados de ensaios físico-químicos.O sistema proposto foi validado por meio de dados reais e os resultados alcançados são compatíveis com aqueles obtidos por meio das técnicas convencionais. / The objective of this work was to do a modeling using the inference fuzzy system of the concentration of dissolved gases in insulating mineral oil getting from the physical-chemical results. The idea was to understand the techniques to identify failures on transformers by analyzing the physical-chemical results of the insulating mineral oil.To do that, the data from physical-chemical results and chromatographic results was mapped using the inference fuzzy system. So, by the results of the physical-chemical experiment such as color, density, humidity and so on, its possible to have a estimation of the concentration of dissolved gases in insulating mineral oil. Therefore, its possible to implement techniques to identify failures based on the concentration of dissolved gases using physical-chemical techniques.The propose system was validated by real data. The results using physical-chemical techniques were similar with the results using conventional techniques.
9

Modelagem fuzzy da concentração dos gases dissolvidos em óleo mineral isolante de transformadores baseada em resultados de ensaios físico-químicos / Fuzzy approaching of the concentration of dissolved gases in insulating mineral oil based on physical-chemical results

Rodrigo Luz Campi 19 February 2014 (has links)
O objetivo desse trabalho foi de fazer a modelagem por meio de sistemas de inferência fuzzy da concentração dos gases dissolvidos em óleo mineral isolante à partir dos resultados de ensaios físico-químicos. Dessa forma, objetivou-se estender as técnicas de identificação de falhas em transformadores por meio da análise dos ensaios físico-químicos do óleo isolante. Para tanto adotou-se um mapeamento entre os dados de ensaios físico-químicos e de cromatografia gasosa feito por meio de sistemas de inferência fuzzy. Assim, por meio de resultados de ensaios físico-químicos, como cor, densidade, unidade, entre outro, tem-se uma estimativa da concentração dos gases dissolvidos no óleo mineral isolante do transformador. Assim, torna-se possível empregar técnicas de identificação de falhas baseadas na concentração dos gases dissolvidos, mas, valendo-se dos dados de ensaios físico-químicos.O sistema proposto foi validado por meio de dados reais e os resultados alcançados são compatíveis com aqueles obtidos por meio das técnicas convencionais. / The objective of this work was to do a modeling using the inference fuzzy system of the concentration of dissolved gases in insulating mineral oil getting from the physical-chemical results. The idea was to understand the techniques to identify failures on transformers by analyzing the physical-chemical results of the insulating mineral oil.To do that, the data from physical-chemical results and chromatographic results was mapped using the inference fuzzy system. So, by the results of the physical-chemical experiment such as color, density, humidity and so on, its possible to have a estimation of the concentration of dissolved gases in insulating mineral oil. Therefore, its possible to implement techniques to identify failures based on the concentration of dissolved gases using physical-chemical techniques.The propose system was validated by real data. The results using physical-chemical techniques were similar with the results using conventional techniques.

Page generated in 0.1094 seconds