• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Μελέτη και υπολογισμός του ηλεκτρικού πεδίου σε σύνθετο διάκενο αέρα/διηλεκτρικού

Αλεξόπουλος, Ελευθέριος 14 May 2007 (has links)
Σε ένα διάκενο που αποτελείται από ένα ηλεκτρόδιο υψηλής τάσεως πλαισιωμένο από έναν αριθμό γειωμένων αγωγών, η κατάληξη μίας εκκένωσης σε ένα συγκεκριμένο σημείο έχει μια στοχαστική εξάρτηση από τη γενική διαμόρφωση του ηλεκτρικού πεδίου που επικρατεί στο διάκενο. Η λέξη «στοχαστική» έχει την έννοια ότι πρακτικά οποιοδήποτε γειωμένο σημείο μέσα στο διάκενο κατέχει μία πιθανότητα να δεχθεί την εκκένωση, αλλά αυτή η πιθανότητα μπορεί να είναι διαφορετική για τα διάφορα σημεία. Επιπλέον, αν το διάκενο αποτελείται από περισσότερα από ένα διηλεκτρικά, το σημείο κατάληξης της εκκένωσης, όπως και οι παράμετροι της διάσπασης, επηρεάζονται από την παρουσία και τα ηλεκτρικά και γεωμετρικά χαρακτηριστικά των διηλεκτρικών αυτών. Σε ένα απλό διάκενο ακίδας-πλάκας με αέρα, τα σημεία κατάληξης όλων των εκκενώσεων είναι συγκεντρωμένα γύρω από το ίχνος του άξονα της ακίδας, που είναι η θέση της μέγιστης πιθανότητας. Η πιθανότητα μία εκκένωση να καταλήξει σε μία συγκεκριμένη θέση του επιπέδου, διαφορετική από τον άξονα της εκκένωσης, μειώνεται όσο μεγαλώνει η απόσταση της θέσης αυτής από τον άξονα. Αν ένας γειωμένος αγωγός εισαχθεί στο διάκενο, όπως για παράδειγμα ένας ή περισσότεροι γειωμένοι αγωγοί παράλληλα στο επίπεδο (σχήμα 1), η πιθανότητα μία εκκένωση να καταλήξει, είτε στα σύρματα είτε στο επίπεδο, εξαρτάται από τη συγκεκριμένη θέση των καλωδίων. Σκοπός της παρούσας εργασίας είναι να καθορίσει: α) τη συνδυασμένη επίδραση διαφόρων παραγόντων στην πιθανότητα μια εκκένωση να καταλήξει σε γειωμένους αγωγούς, τοποθετημένους σε ένα διάκενο ακίδας-πλάκας, β) την επίδραση των παραγόντων αυτών στα χαρακτηριστικά της διάσπασης, από τα οποία το σημαντικότερο είναι η τάση διάσπασης και γ) την μορφή του ηλεκτρικού πεδίου που δημιουργείται μεταξύ ακίδας-πλάκας καθώς και την επίδραση των παραπάνω παραγόντων σε αυτό. . Πιο συγκεκριμένα στη μελέτη που έγινε η απόσταση των γειωμένων συρμάτων από το πλέγμα ήταν d2=2,5 cm και μελετήθηκε η επίδραση της πυκνότητας του πλέγματος (χρησιμοποιήθηκαν 7 διαφορετικά πλέγματα και λαμαρίνα) και της απόστασης των συρμάτων α cm. Τα δεδομένα που προέκυψαν από την πειραματική διαδικασία, δηλαδή η τιμή της τάσης διάσπασης σε κάθε περίπτωση, κανονικοποιήθηκαν με τους συντελεστές διόρθωσης υγρασίας και πυκνότητας του αέρα, έγινε δηλαδή αναγωγή των τιμών σε κανονικές συνθήκες. Έπειτα γραφικά προέκυψε μία πρώτη προσέγγιση της τιμής της τάσεως U50% και της διασποράς σ. Χρησιμοποιήσαμε ένα πρόγραμμα σε γλώσσα προγραμματισμού C, το οποίο υλοποιούσε τη μέθοδο της μέγιστης πιθανοφάνειας, προκειμένου να προκύψει με μεγαλύτερη ακρίβεια η τιμή της τάσης διάσπασης U50%, η διασπορά σ και τα όρια αξιοπιστίας τους. Σαν αρχικές τιμές των U50% και σ, χρησιμοποιήθηκαν αυτές που προέκυψαν από τη γραφική εκτίμηση. Τέλος, οι τελικές τιμές της τάσης διάσπασης, καθώς και οι τιμές της ικανότητας σύλληψης των γειωμένων συρμάτων, δηλαδή η πιθανότητα οι εκκενώσεις να καταλήξουν σε αυτά, ομαδοποιήθηκαν και προέκυψαν τα τελικά διαγράμματα. Η εργασία ολοκληρώθηκε με παρατηρήσεις σχετικά με τη συμπεριφορά της τάσης διάσπασης και της ικανότητας σύλληψης των γειωμένων συρμάτων και έγινε μια προσπάθεια αιτιολόγησής. / -
2

Πειραματική μελέτη σύνθετου διάκενου ελαίου χάρτου

Κόικα, Αλεξάνδρα 13 January 2015 (has links)
Είναι γνωστό ότι ο πιο σημαντικός παράγοντας για την προστασία και τη σωστή λειτουργία ενός εξοπλισμού υψηλής τάσης είναι η μόνωση του. Η πιο διαδεδομένη μορφή μόνωσης είναι η χρήση υγρών διηλεκτρικών, και συγκεκριμένα ελαίων. Αρχικά, χρησιμοποιούσαν μόνο ορυκτά έλαια ως μονωτικό υλικό διοτί ήταν εύκολη η διάθεση τους. Τα τελευταία όμως χρόνια, ήθισται να προτιμούνται φυτικά έλαια έναντι των ορυκτών, χάρη των ιδιοτήτων και πλεονεκτημάτων που παρουσιάζουν. Τα βασικά πλεονεκτήματα είναι η φιλικότητα τόσο προς το περιβάλλον όσο και στον άνθρωπο, η μη τοξικότητα τους, το υψηλό σημείο ανάφλεξης, η βιοδιάσπαση τους, καθώς και η βελτίωση της απόδοσης του μετασχηματιστή. Σκοπός της παρούσας διπλωματικής εργασίας είναι η διερεύνηση της συμπεριφοράς του φυτικού ελαίου FR3 κατά τη διάρκεια καταπόνησης του με εναλλασσόμενη τάση (AC) και η σύγκριση του με το ορυκτό έλαιο. Ακόμη, στόχος μας είναι να παρατηρήσουμε τη συμπεριφορά του FR3 σε συνδυασμό με μονωτικό χαρτί, αφού γνωρίζουμε ότι τα τυλίγματα μετασχηματιστών υψηλής τάσης μονώνονται και από τα 2 υλικά. Για το λόγο αυτό χρησιμοποιήθηκε η συσκευη BAUR oil tester DTA 100C που αποτελεί κομμάτι του ηλεκτρολογικού εξοπλισμού του εργαστηρίου των υψηλών τάσεων. Η παραγωγή γραμμικά αυξανόμενης εναλλασσόμενης (AC) τάσης με σταθερό ρυθμό 2kVrms/s και οι μετρήσεις της τάσης διάσπασης έγιναν από τη συσκευή αυτή. Τα διάκενα στα οποία καταπονήθηκε το φυτικό έλαιο είναι: rogowski 2mm, ακίδα-πλάκα 2mm, rogowski-πλάκα 2.5mm.Στη συνέχεια, πραγματοποιήσαμε μετρήσεις με διάταξη rogowski 2.5mm σε φυτικό λάδι χωρίς ανάδευση και σε καταπονημένο σε κρουστική τάση. Οι επόμενες μετρήσεις αφορούσαν το σύνθετο διάκενο χαρτί –λάδι και χρησιμοποιήσαμε 2 τύπους χαρτιού: DPP PAPER και KRAFT PAPER σε διάταξη rogowski 2.5mm. Τέλος, χρησιμοποιήσαμε ορυκτό έλαιο σε διάκενα rogowski 2.5mm και Ακίδα πλάκα 2,5 mm Επίσης, για να είμαστε άρτιοι στη σύγκριση των δύο τύπων ελαίων, πραγματοποιήσαμε αναλυτική στατιστική έρευνα ώστε να διαπιστώσουμε αν η κατανομή των πειραματικών αποτελεσμάτων προσεγγίζει την κανονική. Συγκεκριμένα, χρησιμοποιήσαμε το διάγραμμα διασποράς για την εκτίμηση της κατανομής. Έπειτα, με τη χρήση της συνάρτησης πυκνότητας πιθανότητας παρατηρήσαμε εποπτικά αν τα πειραματικά αποτελέσματα ακολουθούν κανονική κατανομή και υπολογίσαμε την ασσυμμετρία και την κυρτωση αυτών. Tέλος, χρησιμοποιήθηκαν τρία κριτήρια κανονικότητας, το Shapiro-Wilk, το Kolmogrov-Smirnov, και το Anderson-Darling καθώς και το διάγραμμα Normal Plot. Κρίνοντας από τα αποτελέσματα, προκύπτει ότι η τάσης διάπασης για το φυτικό έλαιο είναι μεγαλύτερη σε σχέση με το ορυκτό. Επίσης, είναι φανερό ότι η ύπαρξη σύνθετου διακένου (έλαιο – χαρτί) μειώνει την τάση διάσπασης του FR3. Τέλος, φαίνεται ότι σχεδόν για όλες τις διατάξεις, τα πειραματικά αποτελέσματα ακολουθούν την κανονική κατανομή. / It is known that the most important factor for the protection and proper operation of high voltage equipment is the insulation achievements. The most widespread form of insulation is the use of liquid dielectrics, manely dielectric oils. Initially, only mineral oil were used as an insulating material because it was easily available. However, the last decades vegetable oils are preferred to fossil thanks to the properties and advantages they present. The main advantages are the friendliness of both the environment and humans, non- toxicity, high flash point, biodegradation, as well as improving the efficiency of the transformer. The purpose of this thesis is to investigate the behavior of natural oil FR3 during stress with alternating current (AC) and compared with the mineral oil. Furthermore, our aim is to observe the behavior of this oil in combination with insulating paper, since we know that the high voltage transformer windings are insulated from the two materials. For this reason, using the device BAUR oil tester DTA 100C which is part of the electrical equipment of High Voltage laboratory. The production increased linearly alternating (ac) voltage steadily 2kVrms/s, and measurements of the breakdown voltage were made of this device.The gaps that we were measured are: rogowski 2mm, point-plane 2mm, rogowski-plane 2mm. Then, we measured the breakdown voltage for rogowski 2,5mm without stirring and for an overworked oil. Next measurments concered the combination of paper-oil, where we used two types of insulating paper:DPP and KRAFT PAPER (rogowski 2.5mm).finally we measured mineral oil in gaps: rogowski 2.5 mm and point-plane 2.5 mm Also, being correct to compare the two types of oils, we conducted a detailed survey about whether the experimental results follow the normal distribution. Specifically, we used the scatter plot to estimate the distribution of our experimental results. Then, using the probability density function we observed if the experimental results follow a normal distribution and calculated the coefficients of skewness and kurtosis. Finally, we used two hypothesis tests, the Shapiro – Wilk test,the Kolomogrov-Smirnov test and the Anderson-Darling, as well as the Normal Probability Plot. Αccording to the results, we observe that the breakdown voltage of natural ester oil is greater than mineral’s oil. Also, it is obvious that the existence of a complex gap (oil-paper) reduces the breakdown voltage. Finally, it seems that for almost all the provisions, the experimental results follow the normal distribution.
3

Μελέτη στοχαστικών μοντέλων για τη μελέτη της τάσης διάσπασης διάκενων με σύνθετη μόνωση

Λάσκος, Γεώργιος 13 September 2011 (has links)
Σκοπός της παρούσης διπλωματικής εργασίας είναι η μελέτη στοχαστικών μοντέλων για τη μελέτη της τάσης διάσπασης διακένων με σύνθετη μόνωση. Αρχικά, περιγράψαμε τη συμπεριφορά των υγρών σε ισχυρά ηλεκτρικά πεδία. Μιλήσαμε για την εξάρτηση της πίεσης από ένα ηλεκτρικό πεδίο και την ηλεκτρική αγωγιμότητα σε ένα ισχυρό ηλεκτρικό πεδίο. Ακόμα, αναφέραμε κάποιες πληροφορίες για την κατανομή της πίεσης σε ένα διηλεκτρικό υγρό. Μετά περιγράψαμε τη συμπεριφορά της αέριας φάσης των υγρών σε ισχυρά ηλεκτρικά πεδία. Μιλήσαμε για το ρόλο των φυσαλίδων στην κατάσταση του διηλεκτρικού υγρού και για τα φαινόμενα που συμβαίνουν σ' αυτές. Αργότερα, δώσαμε κάποιες πληροφορίες για τη διάδοση της εκφόρτισης σε μικρά διάκενα και αναφέραμε την εξάρτησή της από την πίεση. Επιπλέον, αναλύσαμε τη διάδοση της εκφόρτισης σε διάκενα με ανομοιογενές πεδίο. Περιγράψαμε την κατασκευή μιας εκφόρτισης και την επίδραση του στερεού διηλεκτρικού στην τάση διάσπασης. Ακόμη, δώσαμε πληροφορίες για την περιοχή ιονισμού και το κανάλι leader. Στη συνέχεια, αναλύσαμε την εξάρτηση της διηλεκτρικής αντοχής από ορισμένους παράγοντες. Οι παράγοντες στους οποίους αναφερθήκαμε είναι: η διάρκεια, η μορφή και η συχνότητα των παλμών τάσης, η πολικότητα της τάσης, η πίεση, η θερμοκρασία, η χημική φύση και σύνθεση των υγρών και η γεωμετρία του διακένου. Επίσης, αναλύσαμε τους φυσικούς μηχανισμούς έναρξης εκφόρτισης. Περιγράψαμε το μηχανισμό έναρξης εκφόρτισης με τη βοήθεια φυσαλίδων και κάποιους άλλους μηχανισμούς όπως τους μηχανισμούς έναρξης εκφόρτισης με ιονισμούς. Αργότερα, αναφέραμε τους μηχανισμούς διάδοσης εκφόρτισης. Έγινε περιγραφή της διαδικασίας διάδοσης του γρήγορου καναλιού και του αργού καναλιού. Ακόμα, μιλήσαμε για τη μετατροπή του αρχικού καναλιού σε leader. Στη συνέχεια, κάναμε μια εκτενή εισαγωγή στα στοχαστικά μοντέλα και αναφερθήκαμε στη χρησιμότητα τους, στις διάφορες κατηγορίες τους και στην εφαρμογή τους στον τομέα των ηλεκτρικών διασπάσεων. Για το λόγο αυτό, περιγράψαμε τις βασικές αρχές για το μοντέλο FFC και το μοντέλο του Biller. Μετά από όλα αυτά, αναλύσαμε τη διαδικασία που ακολουθήσαμε κατά τις εξομοιώσεις. Κάναμε λεπτομερή περιγραφή του προγράμματος που χρησιμοποιήσαμε για τις εξομοιώσεις. Οι εξομοιώσεις έγιναν για 2 διάκενα 2,5mm ομοιογενούς και ανομοιογενούς πεδίου και 2 διάκενα 1,5mm ομοιογενούς και ανομοιογενούς πεδίου. Κατά τις εξομοιώσεις το πάχος του φράγματος θεωρήθηκε σταθερό, ενώ μεταβάλαμε τη θέση του και το συντελεστή γήρανσης του λαδιού. Για τα διάκενα ομοιογενούς πεδίου, τοποθετήσαμε το φράγμα σε 3 διαφορετικές θέσεις και για τα διάκενα ανομοιογενούς διακένου τοποθετήσαμε το φράγμα σε 5 διαφορετικές θέσεις. Οι εξομοιώσεις πραγματοποιήθηκαν σε υπολογιστή του Εργαστηρίου Υψηλών Τάσεων του τμήματος Ηλεκτρολόγων Μηχανικών και Τεχνολογίας Υπολογιστών του Πανεπιστημίου Πατρών. Επιπλέον, παραθέσαμε σε πίνακες τα αποτελέσματα που προέκυψαν από τις εξομοιώσεις. Στη συνέχεια κατασκευάσαμε διαγράμματα, για να καταλήξουμε σε κάποια συμπεράσματα. Για τα διάκενα ομοιογενούς πεδίου, σχεδιάσαμε την τάση V συναρτήσει του gi για τις διάφορες θέσεις του φράγματος. Για τα διάκενα ανομοιογενούς πεδίου, σχεδιάσαμε την τάση V συναρτήσει της σχετικής απόστασης (d1/d) του φράγματος από το πάνω ηλεκτρόδιο για διάφορες τιμές του gi. Έγινε σύγκριση μεταξύ των καμπυλών που προέκυψαν για τα διάκενα ανομοιογενούς πεδίου, με καμπύλη που προέκυψε από πειραματικά δεδομένα και βρίσκεται στο “Barrier Effect on the Dielectric Strength of Oil Gaps under DC Voltage” των A. Zouaghi και Α. Beroual. Στη συνέχεια, σχεδιάσαμε την τάση V συναρτήσει της σχετικής απόστασης (d1/d) του φράγματος από το πάνω ηλεκτρόδιο για διάφορες τιμές του gi, για τα διάκενα ομοιογενούς και ανομοιογενούς πεδίου μαζί. Τέλος, μετά τις συγκρίσεις διαπιστώσαμε ότι τα αποτελέσματά μας συμφωνούν μόνο σε κάποιες περιπτώσεις με τα πειραματικά δεδομένα. Αυτό συμβαίνει λόγω της απλότητας των μοντέλων και ίσως μηχανισμών που δεν έχουν συνυπολογιστεί. Οπότε, συμπεράναμε ότι το μοντέλο που χρησιμοποιήσαμε, απαιτεί βελτίωση. / The purpose of this diploma thesis is the study of stochastic models about the breakdown voltage of complex insulation gaps. Initially, we described the behavior of liquids in strong electric fields. We mentioned the dependence of the pressure on an electric field and electric conductivity in strong electric fields. We reported some information about the pressure distribution in a dielectric liquid. Afterwards, we described the behavior of gaseous phase in liquids in strong electric fields. We reported the influence of the bubbles in the state in the dielectric liquids and the phenomena at them. Later, we gave some information about the discharge propagation in short gaps and we refered its dependence on the pressure. Moreover, we analyzed the discharge propagation in gaps with a non uniform field. We described the structure of a discharge and the influence of the solid dielectric on the breakdown voltage. Also, we gave information about the ionization region and the leader channel. Afterwards, we analyzed the dependence of the dielectric strength on certain factors. The factors in which we were reported are: the duration, the shape and the frequency of voltage pulses, the voltage polarity, the pressure, the temperature, the chemical nature of liquids and the gap geometry. Also, we analyzed the physical discharge initiation mechanisms. We described the bubble discharge initiation mechanism and some other mechanisms like the ionization discharge initiation mechanism.Later, we mentioned the mechanisms of discharge propagation. We described the propagation process of the fast and the slow channel. Also, we were reported in the conversion of the initial channel into leader channel. Afterwards, we did an extensive import in the stochastic models and were reported in their usefulness, in their various categories and in their application in the sector of electric breakdown. For this reason, we described the basic elements of the FFC and the Biller model. After all these we analyzed the process that we followed at the simulations. We did a detailed description of the program used for the simulations. We did simulations for 2 gaps 2,5mm uniform and non uniform field and 2 gaps 1,5mm uniform and non uniform gaps. During the simulations, the barrier thickness was considered stable, while we were changing the position and the factor of ageing of the oil. For the uniform field gaps, we placed the barrier in 3 different positions and for the non uniform gaps, we placed the barrier in 5 different positions. The simulations were realised at computer at High Voltage Laboratory of the department of Electrical and Computer Engineering of the University of Patras, Greece. Moreover, we mentioned in tables the results that resulted from the simulations. Then, we drew diagrams to make some conclusions. For the uniform field gaps, we drew the voltage V as a function of the factor of ageing of the oil gi for the various positions of the barrier. For the non uniform field gaps, we drew the voltage V as a function of the relative distance (d1/d) of the barrier from the upper electrode for the various numbers of gi. We did comparison between the curves that resulted for the non uniform gaps and the curve tht resulted for experimental data and is found in “ Barrier Effect on the Dielectric Strength of Oil Gaps under DC Voltage” of A. Zouaghi and Α. Beroual. Afterwards, we drew the voltage V as a function of the relative distance (d1/d) of the barrier from the upper electrode for the various numbers of gi, for both uniform and non uniform gaps. Finally, after the comparisons we realised that the results agree only in some cases with the experimental data. This may happened because of the simplicity of the models and perhaps mechanisms that have not been included. So, we concluded that the model that we used, need improvement.
4

Φωτοκαταλυτική διάσπαση οργανικών ρύπων προτεραιότητας σε υδατικά συστήματα

Αντωνοπούλου, Μαρία 25 May 2015 (has links)
Η ανάγκη αντιμετώπισης του προβλήματος της ρύπανσης των επιφανειακών και υπόγειων υδάτων έχει οδηγήσει στην ανάπτυξη νέων και αποτελεσματικών μεθόδων για την απομάκρυνση έμμονων και μη βιοαποικοδομήσιμων ενώσεων από το νερό και τα υγρά απόβλητα. Η παρούσα διατριβή πραγματεύτηκε τη συστηματική μελέτη της διάσπασης ρύπων προτεραιότητας και αναδυόμενων ρύπων που ανήκουν σε διαφορετικές χημικές κατηγορίες (DEET, metribuzin, 2-ισοπρόπυλο-3-μεθόξυ πυραζίνη, η πενταχλωροφαινόλη, βενζοϊκό οξύ, Cr(VI) και φαινολικές ενώσεις) με τη μέθοδο της ετερογενούς φωτοκατάλυσης και τη χρήση εμπορικά διαθέσιμων δραστικών μορφών TiO2 και τροποποιημένων σωματιδίων ΤiΟ2 με αμέταλλα που παρουσιάζουν φωτοκαταλυτική δραστικότητα στο ορατό φάσμα της ακτινοβολίας. Για το σύνολο των ενώσεων που μελετήθηκαν, η έρευνα επικεντρώθηκε: i) στη μελέτη της κινητικής της αποδόμησης και της ολικής ανοργανοποίησης τους με τη μέθοδο της ετερογενούς φωτοκατάλυσης, ii) στη μελέτη της επίδρασης λειτουργικών παραμέτρων στην απόδοση της φωτοκαταλυτικής απομάκρυνσης των ρύπων και στην εύρεση των βέλτιστων συνθηκών με την εφαρμογή των δύο ευρέως χρησιμοποιούμενων χημειομετρικών μεθόδων, της μεθοδολογίας επιφάνειας απόκρισης (RSM) και των τεχνητών νευρωνικών δικτύων (ANNs), iii) στην ανίχνευση και ταυτοποίηση ενδιάμεσων προϊόντων διάσπασης των οργανικών ρύπων με φασματομετρικές τεχνικές όπως υγρή χρωματογραφία-φασματομετρία μαζών υψηλής διακριτικής ικανότητας και ακρίβειας μάζας με αναλυτή τροχιακής παγίδας (Orbitrap) και αέρια χρωματογραφία–φασματομετρία μάζας με την τεχνική ιοντισμού με πρόσκρουση ηλεκτρονίων (Εlectron Impact, EI) και φασματοσκοπία ηλεκτρονικού παραμαγνητικού συντονισμού, iv) στη συνεισφορά των δραστικών ειδών οξυγόνου, οπών και ηλεκτρονίων στη φωτοκαταλυτική αποικοδόμηση των ρύπων, v) στη μελέτη του ρόλου των φυσικών συστατικών (χουμικά και φουλβικά οξέα) διαφόρων υδατικών συστημάτων καθώς και στην εκτίμηση της επίδρασης του υδατικού μέσου στην κινητική της διεργασίας, vi) στην εκτίμηση της τοξικότητας πριν και κατά τη διάρκεια της φωτοκαταλυτικής επεξεργασίας. Με την εφαρμογή της ετερογενούς φωτοκατάλυσης επετεύχθη πλήρης απομάκρυνση όλων των ρύπων-μοντέλων που μελετήθηκαν και υψηλός βαθμός ανοργανοποίησης των διαλυμάτων τους. H φωτοκαταλυτική διάσπαση λαμβάνει χώρα σε ποσοστό μεγαλύτερο του 90% σε χρόνους που κυμαίνονται από 20-180 λεπτά ανάλογα με το μελετώμενο ρύπο. Ένας μεγάλος αριθμός κύριων προϊόντων διάσπασης και τουλάχιστον ένα ισομερές για τα περισσότερα από αυτά, ταυτοποιήθηκε κατά τη φωτοκαταλυτική διάσπαση της PCP, του DEET, του ΜΕΤ και της ΙPMP με τη χρήση προηγμένων τεχνικών φασματομετρίας μάζας. Με βάση τα προϊόντα που ταυτοποιήθηκαν, προτάθηκαν οι μηχανισμοί της φωτοκαταλυτικής διάσπασης των μελετώμενων ρύπων που περιλαμβάνουν κυρίως αντιδράσεις υδροξυλίωσης, οξείδωσης και απαλκυλίωσης. Η οξείδωση μέσω ριζών υδροξυλίου (HO•)βρέθηκε να αποτελεί το κύριο οξειδωτικό είδος σε όλα τα μελετώμενα συστήματα. Η δοκιμή τοξικότητας που πραγματοποιήθηκε, πριν και κατά τη διάρκεια της φωτοκαταλυτικής επεξεργασίας των οργανικών ρύπων έδειξε ότι η μέθοδος της ετερογενούς φωτοκατάλυσης οδηγεί σε πλήρη αποτοξικοποίηση των διαλυμάτων. Σύμφωνα με τα αποτελέσματα της φωτοκαταλυτικής οξείδωσης των οργανικών ρύπων-μοντέλων και της φωτοκαταλυτικής αναγωγής του Cr(VI) που μελετήθηκαν στην παρούσα διατριβή, η μέθοδος της ετερογενούς φωτοκατάλυσης μπορεί να αποτελέσει μια αποδοτική εναλλακτική πρόταση αντιρρύπανσης έναντι των κλασσικών μεθόδων. Η ουσιαστική λύση σε προβλήματα ρύπανσης αποφεύγοντας τη μεταφορά των ρύπων από τη μία φάση στην άλλη, η δυνατότητα χρήσης και αξιοποίησης ήπιων μορφών ενέργειας όπως η ηλιακή ακτινοβολία και η σύζευξη της μεθόδου με άλλες βιολογικές ή/και φυσικοχημικές μεθόδους επεξεργασίας αποδεικνύουν τις μεγάλες προοπτικές που παρουσιάζει. / In order to avoid deterioration of water resources, considerable efforts have been devoted to develop suitable purification methods that can easily remove recalcitrant (persistent) and non-biodegradable contaminants from water and wastewater. In the present thesis the photocatalytic removal of selected priority pollutants and emerging contaminants belonging in different chemical categories has been investigated in detail. DEET, metribuzin, 2 isopropyl-3-methoxy pyrazine, pentachlorophenol (PCP), benzoic acid (BA), Cr(VI) and phenolic compounds were selected as target compounds. The commercial form of TiO2 (Degussa P25) and NF-codoped TiO2, a material with improved photo efficiency and visible light response were used as photocatalysts. The main objectives of this thesis were: i) to evaluate the kinetics of selected pollutants disappearance and mineralization, ii) to investigate the effect of significant parameters on the total process efficiency as well as to optimize the photocatalytic procedure by means of chemometric optimization tools such as central composite design, response surface methodology and artificial neural networks, iii) to identify the transformation products formed during the photocatalytic treatment by using powerful analytical techniques such as high resolution accurate mass LC-MS, GC–MS and EPR spectroscopy, iv) to assess the role of the reactive species in the reaction mechanism using different scavengers, v) to assess the macroscopic effects of DOM (HA, FA) and water matrix on the photocatalytic degradation and vi) to evaluate the toxicity along the photocatalytic process. By the application of heterogeneous photocatalysis almost compete removal of the selected model contaminants and high percentages of mineralization were achieved. Photocatalytic removal (> 90%) was succeeded after 20-180 min of irradiation time, depending on the studied pollutant. Numerous different structures of transformation products (TPs), with at least one isomer for the majority of them, were identified with high resolution accurate mass liquid chromatography (HR-LC–MS) and gas chromatography mass spectrometry (GC–MS). Based on by-product identification using HR-LC-MS and GC–MS techniques possible degradation pathways were proposed. The pathways mainly include hydroxylation, oxidation and dealkylation reactions. Hydroxyl radicals (HO•) were determined to be the predominant reactive species during photocatalysis in all the studied systems. Toxicity assessment revealed the efficiency of the photocatalytic treatment to achieve almost complete detoxification of the solution. According to the results obtained for the photocatlytic oxidation of the studied organic pollutants-models and photocatalytic reduction of Cr(VI), heterogeneous photocatalyis was shown to be a great potential as a sustainable treatment technology. Ιts inherent destructive nature, not involving mass transfer, the potential use of solar radiation as well as the combination of heterogeneous photocatalysis with biological and/or physicochemical methods make this method particularly attractive for environmental decontamination and detoxification.
5

Πειραματική μελέτη της επίδρασης των διεπιφανειών στη συμπεριφορά στερεών μονώσεων του εξοπλισμού δικτύων υψηλής τάσης

Βιτέλλας, Ισίδωρος 25 June 2007 (has links)
Είναι γνωστό ότι οι διεπιφάνειες παίζουν σηµαντικό ρόλο στη συµπεριφορά των στερεών µονώσεων, ιδιαίτερα των στερεών συνθετικών µονώσεων µέσα στις οποίες δηµιουργούνται µακροσκοπικές διεπιφάνειες µεταξύ των µονωτικών στρωµάτων και µικροσκοπικές διεπιφάνειες µεταξύ των κυρίων µονωτικών υλικών και του πλήσµατος, που προστίθεται στις µονώσεις για τη βελτίωση της ηλεκτρικής και της µηχανικής τους αντοχής. Αρκετοί ερευνητές έχουν ασχοληθεί πειραµατικά µε τις επιδράσεις διαφόρων παραµέτρων των διεπιφανειών στην ηλεκτρική γήρανση των µονώσεων. Τέτοιες παράµετροι είναι η ασκούµενη πίεση µεταξύ των στρώσεων των µονωτικών υλικών, η τραχύτητα των εφαπτόµενων επιφανειών, η τιµή της πεδιακής έντασης στις διεπιφάνειες και η δηµιουργία φορτίων χώρου στις διεπιφάνειες. Άλλοι ερευνητές έχουν ασχοληθεί µε την επίδραση των διαφραγµάτων στην ηλεκτρική αντοχή των µονώσεων. Στην παρούσα διδακτορική διατριβή ερευνάται πειραµατικά η επίδραση των παρακάτω παραµέτρων των διεπιφανειών στα ηλεκτρικά χαρακτηριστικά των στερεών µονώσεων, σε οµογενές και ανοµοιογενές ηλεκτρικό πεδίο: α) της παραµέτρου ξ, που καθορίζει τη θέση µιας διεπιφάνειας µέσα στο µονωτικό διάκενο και ορίζεται ως ξ=x/y, ο λόγος της απόστασης x της διεπιφάνειας από το ηλεκτρόδιο ΥΤ προς την απόσταση y µεταξύ των ηλεκτροδίων, β) της παραµέτρου ψ=ε1/ε2, που ορίζεται ως ο λόγος των τιµών της διηλεκτρικής διαπερατότητας των υλικών που σχηµατίζουν την διεπιφάνεια και γ) του αριθµού n των διεπιφανειών µέσα στο µονωτικό διάκενο. ∆ιερευνάται επίσης, η µεταβολή ηλεκτρικών χαρακτηριστικών των µονώσεων µε διεπιφάνειες, σε σχέση µε την ένταση του ηλεκτρικού πεδίου καταπόνησης και σε συνδυασµό µε τις παραπάνω παραµέτρους. Η έρευνα υλοποιήθηκε σε τρία στάδια. Πρώτα σχεδιάσθηκαν και κατασκευάσθηκαν διάφορες κατηγορίες δοκιµίων ανάλογα µε τον τύπο των διεπιφανειών τους και τη διάταξη των ηλεκτροδίων, καθορίσθηκαν τα πειράµατα για τη µέτρηση της ηλεκτρικής αντοχής των δοκιµίων και τη µέτρηση ηλεκτρικών χαρακτηριστικών τους σε διάφορες πεδιακές εντάσεις. Ύστερα, σχεδιάσθηκαν και κατασκευάσθηκαν ειδικές πειραµατικές κυψέλες, καθορίσθηκε η διαδικασία εκτέλεσης των πειραµάτων και εκτελέσθηκαν τα πειράµατα. Τέλος, έγινε η επεξεργασία των µετρήσεων, η µελέτη και η ανάλυση των πειραµατικών αποτελεσµάτων και εξήχθησαν τα συµπεράσµατα. i Για τον σχεδιασµό των δοκιµίων και των πειραµατικών κυψελών και για τον καθορισµό των πειραµάτων ελήφθησαν υπόψη στοιχεία που αφορούν στη δοµή των στερεών πολυµερών µονωτικών υλικών και στους µηχανισµούς διάσπασης και γήρανσης των στερεών συνθετικών µονώσεων, καθώς και επιστηµονικές εργασίες άλλων ερευνητών που αναφέρονται στη βιβλιογραφία. Στα δοκίµια δηµιουργήθηκε ένας από τους δυο τύπους διεπιφανειών, που εµφανίζονται συχνά στις στερεές µονώσεις του εξοπλισµού υψηλής τάσης: α) διεπιφάνειες µεταξύ ενσωµατωµένων στερεών µονωτικών υλικών και β) διεπιφάνειες µεταξύ µονωτικών φύλλων. Στην κατηγορία των δοκιµίων µε τον πρώτο τύπο διεπιφανειών κατασκευάσθηκαν δοκίµια από κύριο µονωτικό υλικό LDPE (low density polyethylene, πολυαιθυλένιο χαµηλής πυκνότητας), µε ένα διάφραγµα στο εσωτερικό τους κατασκευασµένο από LDPE µε φεροηλεκτρικό πλήσµα PZT (lead zirconate titanate, πρόσθετο µολύβδου-ζιρκονίου-τιτανίου), καθώς και δοκίµια από LDPE µε διάφραγµα από CP (chlorinated paraffin, χλωρική παραφίνη). ∆ηµιουργήθηκαν οµάδες δοκιµίων µε διάφορες τιµές των παραµέτρων ξ και ψ της πρώτης τους διεπιφάνειας. Όλα τα δοκίµια είχαν ίδιο πάχος (950µm) και τα πάχη των διαφραγµάτων τους ήταν 100, 200 ή 20 µm, κατά περίπτωση. Συνολικά κατασκευάσθηκαν 520 δοκίµια, στα οποία είχαν ενσωµατωθεί ηλεκτρόδια χαλκού µε εξάχνωση, σε διάταξη πλάκας-πλάκας. Επίσης, κατασκευάσθηκαν δοκίµια από διαφανές µονωτικό υλικό ΡΜΜΑ (polymethyl methacrylate, πολυµεθακρυλικό µεθυλεστέρα) µε διάφραγµα από ER (epoxy resin, εποξειδική ρητίνη) και πλήσµα ΡΖΤ. Η διάταξη των ηλεκτροδίων στα δοκίµια ΡΜΜΑ ήταν ακίδα-πλάκα, η απόσταση των ηλεκτροδίων ήταν 7,5 mm και το πάχος του διαφράγµατος ήταν 50 µm. ∆ηµιουργήθηκαν οµάδες δοκιµίων µε διαφορετικές τιµές της παραµέτρου ξ της πρώτης τους διεπιφάνειας. Συνολικά κατασκευάσθηκαν 100 δοκίµια ΡΜΜΑ. Στην κατηγορία των δοκιµίων µε το δεύτερο τύπο διεπιφανειών κατασκευάσθηκαν δοκίµια από στρώσεις µονωτικών φύλλων, από κύριο υλικό ΡΕΤ (polyethylene terepthalate, τερεφθαλικός πολυεστέρας του πολυαιθυλενίου). ∆ηµιουργήθηκαν οµάδες δοκιµίων µε παραµέτρους τα πάχη των επιµέρους φύλλων και το συνολικό πάχος των δοκιµίων, τη θέση και τον αριθµό των διεπιφανειών µέσα στα δοκίµια. Συνολικά κατασκευάσθηκαν 760 δοκίµια, στις εξωτερικές επιφάνειες των οποίων είχαν ενσωµατωθεί ηλεκτρόδια χαλκού µε εξάχνωση, δε διάταξη πλάκας-πλάκας. Επίσης, κατασκευάσθηκε µια τρίτη κατηγορία δοκιµίων χωρίς διάφραγµα, από LDPE µε πλήσµα ΡΖΤ, για να διερευνηθεί η επίδραση του πλήσµατος στα ηλεκτρικά ii χαρακτηριστικά των δοκιµίων, σε σχέση µε την πεδιακή ένταση καταπόνησης. Κατασκευάσθηκαν 50 δοκίµια πάχους 200 µm, µε ενσωµατωµένα ηλεκτρόδια χαλκού σε διάταξη πλάκας-πλάκας, µε διάφορες τιµές περιεκτικότητας ΡΖΤ. Στα δοκίµια εκτελέσθηκαν πειράµατα διάσπασης µε γραµµικά αυξανόµενη τάση AC και πειράµατα µέτρησης χωρητικότητας, εφδ και ΜΕ µε τάση AC σε διάφορες τιµές από 5% έως 85% της τάσης διάσπασης των δοκιµίων. Στα δοκίµια ΡΜΜΑ έγιναν πειράµατα µέτρησης του χρόνου έναρξης δηµιουργίας δενδριτών µε ταυτόχρονη µέτρηση ΜΕ κατά τη διάρκεια της ηλεκτρικής τους καταπόνησης µε σταθερή τάση AC, και ακολούθησαν µικροσκοπικοί έλεγχοι για τη διερεύνηση των δενδριτών. Επίσης, στα δοκίµια από µονωτικά φύλλα εκτελέσθηκαν πειράµατα µέτρησης του χρόνου διάσπασης µε ταυτόχρονη καταγραφή ΜΕ κατά την ηλεκτρική τους καταπόνηση µε σταθερή τάση AC. Στις πειραµατικές διατάξεις χρησιµοποιήθηκε εξοπλισµός του Εργαστηρίου Υψηλής Τάσης του Κέντρου ∆οκιµών Ερευνών και Προτύπων της ∆ΕΗ ΑΕ και του Εργαστηρίου Υψηλών Τάσεων του Τµήµατος Ηλεκτρολόγων Μηχανικών και Τεχνολογίας Υπολογιστών του Πανεπιστηµίου Πατρών. Σε µια συνδυασµένη ερευνητική προσπάθεια των Εργαστηρίων ΥΤ των Πανεπιστηµίων Πατρών και Tomsk της Ρωσίας, εκτελέσθηκαν στο Εργαστήριο του Tomsk αντίστοιχα πειράµατα σε διαφορετικά δοκίµια από κύριο µονωτικό SR (synthetic rubber, συνθετικό καουτσούκ) και PVC (polyvinyl chloride, χλωριούχο πολυβινύλιο) µε πλήσµα ΡΖΤ, µε έµφαση όµως στην επίδραση της πόλωσης του πλήσµατος σε ηλεκτρικά χαρακτηριστικά των δοκιµίων. Σε κάθε οµάδα δοκιµίων, ανάλογα µε τα πειράµατα που εκτελέσθηκαν σε αυτήν, υπολογίσθηκαν οι τιµές των µέσων όρων και των τυπικών αποκλίσεων των µετρήσεων της ηλεκτρικής αντοχής, της εφδ, της διηλεκτρικής διαπερατότητας και των µέγιστων φορτίων ΜΕ των δοκιµίων, σε διάφορες τιµές της πεδιακής έντασης καταπόνησης. Επίσης, αναλύθηκαν µετρήσεις ΜΕ, των φορτίων, του αριθµού και της φασικής γωνίας εµφάνισης τους. Από τις µετρήσεις του χρόνου έναρξης δηµιουργίας δενδριτών και του χρόνου διάσπασης των δοκιµίων υπολογίσθηκαν οι αντίστοιχοι χρόνοι µε πιθανότητα Ρ=0,632 για τα δοκίµια κάθε οµάδας. Από τις επεξεργασµένες τιµές προέκυψαν τα διαγράµµατα µεταβολής της ηλεκτρικής αντοχής, του χρόνου διάσπασης και του χρόνου έναρξης δηµιουργίας δενδριτών των δοκιµίων, σε σχέση µε τις τιµές ξ, ψ και n των διεπιφανειών, και τα διαγράµµατα µεταβολής της εφδ, της διηλεκτρικής διαπερατότητας και των ΜΕ, σε σχέση µε την πεδιακή ένταση καταπόνησης, για διάφορες τιµές των παραµέτρων ξ και ψ. iii Με βάση τα πειραµατικά αποτελέσµατα µελετήθηκε η επίδραση των διεπιφανειών στη συµπεριφορά των στερεών µονώσεων, εξετάζοντας την επίδραση της θέσης της πρώτης διεπιφάνειας στη διαµόρφωση του ηλεκτρικού πεδίου µέσα σε µονωτικό διάκενο µε διάταξη ηλεκτροδίων ακίδας-πλάκας και µελετώντας την επίδραση της πόλωσης του φεροηλεκτρικού πλήσµατος σε ηλεκτρικά χαρακτηριστικά των συνθετικών µονώσεων. Επίσης, µελετήθηκε η ανάπτυξη δενδριτών στο εσωτερικό των στερεών µονώσεων µε διεπιφάνειες διαφράγµατος, καθώς και η επίδραση του πάχους των στερεών συνθετικών µονωτικών υλικών στη διηλεκτρική τους αντοχή. Τα συµπεράσµατα που προέκυψαν συνοψίζονται στα εξής: Οι τιµές της εφδ και των ΜΕ στις στερεές µονώσεις εξαρτώνται από τις παραµέτρους ξ, ψ και n των διεπιφανειών και αυξάνονται απότοµα όταν η πεδιακή ένταση καταπόνησης υπερβεί µια κρίσιµη τιµή, η οποία στις συνθετικές µονώσεις κυµαίνεται συνήθως στο 25% της ηλεκτρικής τους αντοχής. Η ανίχνευση των κρίσιµων τιµών της πεδιακής έντασης µε τη διαδικασία λήψης µετρήσεων εφδ και ΜΕ σε διαδοχικά αυξανόµενα βήµατα τάσης, δίνει τη δυνατότητα σύγκρισης της ηλεκτρικής αντοχής των µονώσεων χωρίς να απαιτούνται πάντοτε καταστροφικές δοκιµές. Η θέση της πρώτης διεπιφάνειας παίζει σηµαντικά σπουδαιότερο ρόλο στην ηλεκτρική αντοχή των στερεών µονωτικών διακένων απ΄ ότι οι άλλες διεπιφάνειες, επειδή οριοθετεί το πρώτο στρώµα του µονωτικού που εφάπτεται στο ηλεκτρόδιο ΥΤ, µέσα στο οποίο ξεκινούν οι µηχανισµοί γήρανσης και διάσπασης των διακένων. Το πάχος του πρώτου στρώµατος επηρεάζει την εξέλιξη των µηχανισµών αυτών. Η θέση της πρώτης διεπιφάνειας διαφράγµατος επηρεάζει την τιµή της πεδιακής έντασης στην κορυφή της ακίδας και την ανάπτυξη δενδριτών στα διάκενα µε διάταξη ηλεκτροδίων ακίδας-πλάκας. Υπάρχει µια βέλτιστη θέση ξopt της πρώτης διεπιφάνειας, στην οποία τα αντίστοιχα διάκενα αποκτούν τη µεγαλύτερη τιµή της ηλεκτρικής τους αντοχής Εbmax σε σχέση µε την ηλεκτρική αντοχή των διακένων του ιδίου πάχους και από ίδια κύρια υλικά, που έχουν την πρώτη διεπιφάνεια σε άλλες θέσεις. Η θέση ξopt εξαρτάται από το κύριο µονωτικό υλικό των διακένων, ενώ η τιµή Εbmax εξαρτάται από την τιµή ψ. Αυτό αποδίδεται στο γεγονός ότι οι δενδρίτες αναπτύσσονται αρχικά στο πρώτο στρώµα του κύριου µονωτικού, ενώ η αύξηση του µήκους τους επηρεάζεται από τις τιµές ψ. Υπάρχει µια βέλτιστη τιµή ψopt που όταν η πρώτη διεπιφάνεια σχηµατίζεται στη θέση ξopt το αντίστοιχο διάκενο αποκτά τη µέγιστη τιµή Εbmax σε σχέση µε τα διάκενα µε άλλες τιµές ψ στη θέση ξopt, η τιµή αυτή µπορεί να υπερβεί το 60% της ηλεκτρικής αντοχής του διακένου χωρίς διεπιφάνειες. iv / It is known that the interfaces have an efficient effect in solid insulations behavior, especially in solid composed insulations inside of which are created macroscopic interfaces between the different dielectric layers and microscopic interfaces between the main insulating materials and additives that are used to optimize the electric and mechanical behavior of the insulations. Many researchers have investigated the effects of various interface parameters on the electric ageing of solid insulations. Such parameters are the applying pressure between the dielectric layers, the roughness of their adjoining surfaces, the electric field strength at the region of the interfaces and the creation of space charge in the vicinity of the interfaces. Other researchers have investigated the effect of dielectric barriers on the electric breakdown strength of solid insulations. In this research, the effect of the following interface parameters on electric characteristics of solid insulations is experimentally investigated, in homogeneous and nonhomogeneous electric field: a) the effect of the parameter ξ=x/y, the ratio of the distance x of the interface from the high voltage electrode to the distance y between the two electrodes, which defines the interface position inside an insulating gap, b) the effect of the parameter ψ=ε1/ε2, which is the ratio of the dielectric permittivity values of the insulating materials, which form the interfaces and c) the effect of the number n of the interfaces that are formed inside an insulating gap. It is also studied the effect of the electric field strength on electric characteristics of solid insulations having internal interfaces, in relation to the above mentioned parameters of the interfaces. The research was completed in three stages. At first, several categories of specimens were designed and constructed with different type of interfaces in various electrodes arrangement, the experiments were set up for measuring the breakdown voltage and electric characteristics of specimens in a range of values of the electric field strength. Then the test cells were designed and constructed and the suitable equipments were installed in the laboratory, the experimental procedure was set up and the experiments were executed on several specimen groups. Finally, the measurements were processed, the diagrams of the variation of the measuring electric characteristics of the specimens in relation to the above interfaces parameters were derived, the experimental results were studied and analyzed, and the conclusions were taken out. Elements concerning the polymer insulating materials structure, the ageing and the breakdown mechanisms of the solid composed insulations, as well as studies of other researchers, were considered for the designing of the specimens and the test cells, and for the determination of the experimental procedures. Inside the specimens was formed one of the following type of interfaces, which are commonly created in solid insulations of high voltage equipment: a) interfaces between two embodied solid dielectrics and b) interfaces between insulating films. The specimens with the first type of interfaces were constructed with a special procedure from low-density polyethylene (LDPE) as main insulating material and inside them was formed a thin barrier constructed from LDPE with the ferroelectric additive lead zirconate titanate (PZT). Specimens were also constructed from LDPE with a barrier from CP (chlorinated paraffin). Various groups of specimens were created with different values of the ξ and ψ parameters of the first interface of the barrier, which was nearest to the HV electrode. All specimens had the same thickness (950 μm) and the thickness of the barrier was 100, 200 or 20 μm. Copper evaporated plane-plane electrodes were embodied on the surfaces of all specimens. The total number of these specimens was 520. Specimens were also constructed from the transparent material polymethyl methacrylate (PMMA) with a barrier constructed from epoxy resin (ER) with additive PZT. The electrodes in these specimens were in a pin-plane arrangement and the distance between them was y=7,5 mm. The thickness of the barrier was 50 μm. Several groups of specimens were created according to the value of the parameter ξ of the first interface. The total number of PMMA specimens was 100. The specimens with the second type of interfaces were constructed from PET (polyethylene terepthalate) films. Various groups of specimens were created according to the thickness of the films and the total specimen thickness, the number of the films and their interfaces positions inside of the specimens. Copper evaporated plane-plane electrodes were embodied on the specimen’s surfaces. The total number of these specimens was 760. A third kind of specimens without interfaces was also constructed from LDPE with additive PZT, in order to study the effect of the additive material on electric characteristics of solid polymeric insulations. Various groups of specimens were created according to the concentration of the PZT inside them. Copper evaporated plane-plane electrodes were embodied on the surfaces of the specimens. The total number of these specimens was 50. The following experiments were executed on the various specimen groups from main insulating material LDPE and PET films: breakdown experiments with ramp increasing AC voltage, experiments for measuring of the tanδ, capacitance and PD in a range of values of AC voltage from 5% up to 85% of the breakdown voltage of the specimens. Experiments were also executed for measuring the treeing inception time in PMMA specimens during electric stressing with a constant value of AC voltage, while simultaneously PD measurements were recorded from these specimens. Electrical trees were detected inside the specimens with a special microscope. Experiments for measuring the breakdown time and for recording PD measurements of PET specimens were also executed during electric stressing of the specimens with a constant value of AC voltage. Last technology equipments of the of the High Voltage laboratory of the Testing Research and Standards Center (TSRC) of PPC SA and of the High Voltage Laboratory of the Electrical Engineering and Computers Technology Department of the University of Patras were used for the execution of the experiments. In a common researching effort of the High Voltage laboratories of the University of Patras and of the University of Tomsk in Russia, corresponding experiments had been performed at the Tomsk University on other specimens constructed from different main insulating material, SR (synthetic rubber) and PVC (polyvinyl chloride) with additive PZT, with emphasis on the polarization effect of the additive material on electric characteristics of solid composed insulations. The mean values and the typical deviations of the measurements of the electric breakdown strength, tanδ, dielectric permittivity and PD apparent charges of the specimens were calculated in each specimens group, in every step of the measuring voltage. The PD maximum charge values and the PD phase distribution, as well as the number of PD in PET specimens were also analyzed. The treeing inception time and the breakdown time with probability P=0,632 were calculated from the corresponding experimental results in each specimens group. The diagrams concerning the variations of the electric breakdown strength, the breakdown time and the treeing inception time of the specimens, in relation to the values of the ξ and ψ parameters were derived of the above processed measuring values. The diagrams of variations of tanδ and PD values of specimens, in relation to the electric field strength, were plotted for several values of ξ and ψ parameters. After processing the experimental results, the effect of the interfaces on solid insulations behavior was studied by investigating the effect of the position of the first interface on the configuration of the electric field inside an insulating gap with a pin-plane electrodes arrangement, and by studying the polarization effect of the PZT on electric characteristics of solid composed insulations. The treeing growth mechanism in solid composed insulations with barrier interfaces was also analyzed, and the effect of the thickness of a composed insulation layer on its electric breakdown strength was discussed. The main conclusions of this research are the following: The tanδ and PD values in solid insulations, measured in a constant AC electric field strength, are affected from the ξ, ψ and n parameters of the interfaces and are rapidly increased when the electric field strength exceeds a critical value, which in the case of solid composed insulations is commonly at a level of 25% of their electric breakdown strength. The detection of this critical value by taking tanδ and PD measurements in step-by-step procedure with increasing voltage assists to compare the electric breakdown strength of solid insulations without being necessary to execute always disruptive tests. The position of the first interface affects the electric characteristics of solid insulation gaps more than the other interfaces since this interface is the boundary of the first layer in the gap, which is in conduct with the HV electrode, and the ageing and breakdown mechanisms in the gap are started in this layer. The thickness of the first layer influences also the growth of these mechanisms. The position of the first interface of a barrier affects the electric field strength at the tip of the pin electrode and the treeing inception time of solid insulation gaps with pin-plane electrodes arrangement. There is an optimum position ξopt of the first interface at which the corresponding gaps get the maximum value Ebmax of their electric breakdown strength comparing to the electric breakdown strength of others insulation gaps with the same thickness and constructed from the same main insulating materials but having the first interface at different position. The position ξopt is depended from the main insulating material and the value Ebmax is depending from the value ψ. These are giving in reasons that treeing is starting in the first layer from the main insulating material and the lengthening of the branches of the trees is affected from the value ψ. There is also an optimum value ψopt for the first interface forming at the ξopt position, at which the corresponding gap get the maximum value Ebmax comparing to the electric breakdown strength of others gaps with different value ψ at ξopt position, and this value of Ebmax may exceed 60% the electric breakdown strength of the gap without interface.

Page generated in 0.0371 seconds