• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Coronographie à masque de phase: applications aux télescopes et interféromètres au sol et dans l'espace

Riaud, Pierre 20 January 2003 (has links) (PDF)
Je présente dans mon travail de thèse une étude complète du coronographe à quatre quadrants proposé par D. Rouan (2000). Ce nouveau coronographe offre des performances de réjection théoriques extrêmement importantes (>10^6). Ces performances ouvrent des possibilités de détection d'exo-planètes autour des étoiles proches. Les premiers résultats en laboratoire, ont donné des taux d'atténuation de l'étoile centrale supérieurs à 90000\footnote(: le résumée de la thèse indique 44000, mais une calibration fine de la densité employée nous donne 90000. ) sur le pic central. J'ai donc naturellement étudié toutes les utilisations possibles de ce coronographe au sol comme dans l'espace. En premier lieu, il peut être utilisé sur les télescopes au sol avec une optique adaptative à haut Strehl. Des simulations numériques seront présentées dans le cadre du projet ``Planet Finder'' de l'ESO pour la détection des naines brunes et des planètes géantes chaudes autour des étoiles les plus proches. Ensuite, je me suis intéressé à l'utilisation du 4Q sur l'instrument MIRI (Mid InfraRed Imager) du JWST, puis sur un interféromètre spatial (pour ``Terrestrial Planet Finder'') de la NASA. Néanmoins, un des problèmes majeurs du masque à 4 quadrants reste le chromatisme du déphasage de pi pour une utilisation en large bande dans le cadre de TPF. Je présenterai donc des solutions permettant d'achromatiser le coronographe.
2

Etude d'une structure d'interrupteur 4 quadrants à faibles pertes à base de transistors à forts gains / No title available

Benboujema, Chawki Mohamed 18 July 2011 (has links)
S’inscrivant dans le cadre de la gestion de l’énergie dans l’habitat du programme SESAME du pôle de compétitivité S2E2, l’objectif de cette thèse est d’étudier et de proposer une structure d’interrupteur commandable à l’ouverture et à la fermeture, bidirectionnel en tension et en courant et à faible perte énergétique, destiné à connecter tout type de charges sur le réseau alternatif 230V/50Hz. Il n’existe pas à l’heure actuelle de composants interrupteurs monolithiques de ce type. La première partie du mémoire présente les interrupteurs électroniques existants. La deuxième partie, traite des interrupteurs électroniques à base de transistors MOS et des limites de cette technologie unipolaire en termes de compromis de minimisation de surface de puces et de minimisation de la dissipation de puissance. Nous montrons ensuite que l’on peut repousser ces limites en adoptant des solutions à base de transistors bipolaires de puissances et notamment avec des bases fines autoprotégées (Transistors GAT). Le quatrième chapitre présente les résultats d’une étude des caractéristiques à l’état passant et à l’état bloqué de transistors GAT et valide leur aptitude à fonctionner sur le réseau alternatif. Nous montrons plusieurs voies possibles d’amélioration des caractéristiques de ces transistors avant d’étudier leur comportement dans une fonction interrupteur. Nous terminons ce travail en démontrant l’intérêt de la commande des transistors GAT en mode de conduction inverse, intérêt qui nous conduit ensuite à proposer une structure d’interrupteur totalement novatrice, avec la réduction par deux du nombre de composants et donc une réduction accrue de la puissance dissipée dans l’interrupteur. / As part of the energy management for household appliances of the S2E2 competitive pole SESAME program, the objective of this thesis is to propose a bidirectional switch in current and voltage with full turn-off control and low energy loss, ensuring the control of all loads types connected to the mains. The first part of this thesis presents the advantages and disadvantages of discrete or monolithic switches. In the second part, we were interested in electronic switches composed of MOS transistors. Different associations strategies and controls will be tested to reduce the power dissipation of the switch on the one hand, and facilitate control of the device on the other hand. Then we turned to solutions based on power bipolar transistors. The last one, called GAT distinguished itself by its high current gain and its low voltage drop in the on state. By implementing around the active base heavily doped caissons which create a shielding effect, one can increase the structure performances. After the design of this component in our laboratory, the characteristics of the on state and the off state were improved to validate its functionality in AC mains. The study will then focus on different technologies to confirm its performances. Using low metallization resistance and assembly strategy intelligently defined, it has been demonstrated that the performance of this component can be increased. Finally, we proposed a new switch structure using only two transistors GAT. We show that the interesting GAT reverse mode characteristics permit to deflect the load current flowing in the diodes and delete them. So we reduced the important source of power dissipation in the switch.
3

Détermination du niveau d'émission harmonique d'une installation raccordée au réseau de distribution / Determination of harmonic emission level of an installation connected to the distribution network

Denoel, Julien 18 November 2016 (has links)
Afin de maintenir une bonne qualité de l’électricité, les gestionnaires de réseaux doivent maintenir les niveaux de tension harmonique en-dessous de certaines limites spécifiées dans les normes. Les niveaux de tension harmonique résultent des équipements non-linéaires présents dans les installations, qui injectent des courants harmoniques sur le réseau.Dans ce but, une solution consiste à appliquer des limites d’émission à ces installations. Les gestionnaires de réseaux ont besoin pour cela d’un indicateur fiable pour évaluer le niveau d’émission harmonique d’une installation.Dans ce cadre, nous nous sommes tout d’abord intéressés aux différentes méthodes existantes, que nous avons appliqué sur des cas de réseaux simplifiés afin de les évaluer sur plusieurs critères. Nous avons ainsi identifié dans un premier temps les définitions qui répondent le mieux à notre besoin ainsi que leurs limites restectives. Dans un deuxième temps, nous avons amélioré une des définitions retenues en proposant une nouvelle solution : la définition “quatre quadrants”.Cette nouvelle définition permet d’évaluer le courant harmonique émis par une installation sur le réseau en se basant sur les mesures de la tension et du courant au point de livraison de l’installation. Son principal intérêt par rapport aux méthodes existantes est de mieux identifier les installations moyennement perturbatrices sur le réseau. Ce point a été validé en simulation sur un réseau dérivé du benchmark CIGRE. / In order to maintain good power quality, Distribution Systems Operators (DSOs) must keep harmonic voltage levels under limits specified in standards. These harmonic voltages result from non-linear equipment connected in installations, which inject harmonic currents into networks.A possible solution to solve this problem consists to implement emission limits per installation. In order to apply these limits, DSOs need to have an accurate and reliable indicator to assess the harmonic emission of an installation.In this context, we studied different methods from the literature. We implemented each of them on several simplified distribution networks in order to evaluate them on several criteria. First, we identified the most interesting definitions from the literature, and emphasized their respective theorical limits. Then, we improved one of these definitions by proposing a new solution: the “four-quadrants” definition.This new definition is able to assess the harmonic current injected by an installation into the network by using current and voltage measurements at the point of common coupling of this installation. Its main advantage in comparison to other methods is a better detection of “medium” disturbing installations over the network. This advantage has been confirmed by implementing the proposed solution in simulation on a distribution network derived from the CIGRE benchmark.
4

Implémentation et réalisation d'un amplificateur de puissance quatre quadrants

Abida, Ahmed January 2021 (has links) (PDF)
No description available.

Page generated in 0.0504 seconds