• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

High sensitivity optical detection using temporal coherence interferogram phase changes

Coutinho, Ricardo Cesar January 2003 (has links)
No description available.
2

Développement de systèmes de microscopie par cohérence optique pour l'imagerie de la peau / Development of optical coherence microscopy systems for skin imaging

Ogien, Jonas 30 November 2017 (has links)
La microscopie par cohérence optique (OCM) est une technique d'imagerie tomographique basée sur l'interférométrie en lumière blanche permettant d'imager les milieux biologiques à l'échelle microscopique. L'OCM est une méthode particulièrement adaptée à l'imagerie dermatologique, en particulier pour le diagnostic du cancer de la peau, car elle permet d'obtenir des images similaires aux images histologiques sans nécessiter d'effectuer de biopsie.Ces travaux de thèse portent sur le développement de la microscopie par cohérence optique pour l'imagerie de la peau, dans le but de fournir au dermatologue un outil d'imagerie compact, adapté à l'imagerie dermatologique in vivo, et permettant d'obtenir des images à la fois structurelles et fonctionnelles.Un dispositif de microscopie par cohérence optique plein champ (FF-OCM) compact, à éclairage par LED blanche, a tout d'abord été développé, permettant d'obtenir des images tomographiques à très haute résolution (0.7 μm × 1.8 μm) jusqu’à ∼200 μm de profondeur dans la peau. En utilisant une LED de haute puissance, des images de peau in vivo ont pu être obtenues.A partir de ce dispositif de FF-OCM, des méthodes d'imagerie fonctionnelle permettant de cartographier les écoulements sanguins (angiographie) ont été mises en oeuvre. Quatre méthodes, basées sur une analyse du signal interférométrique (temporelle ou fréquentielle), d'images de phase ou d'images d'amplitude ont permis d'imager de l'intralipide s'écoulant dans un modèle de capillaire sanguin.L'imagerie fonctionnelle polarimétrique a aussi été explorée en FF-OCM. Une optimisation du contraste des images polarimétriques a été obtenue en modifiant les composants polarisants d'un montage conventionnel de FF-OCM polarimétrique en fonction de l'échantillon imagé. Cette méthode a été testée sur un échantillon polarisant simple.Finalement, une nouvelle méthode d'OCM, la microscopie par cohérence optique confocale à éclairage « ligne » (LC-OCM) a été étudiée, dans le but de développer un système permettant d'imager la peau in vivo, avec une plus grande profondeur de pénétration dans les tissus que la FF-OCM. Ce système, combinant un filtrage interférométrique et un filtrage confocal, a permis d'obtenir des images de peau in vivo en coupe verticale et en coupe en face, avec une résolution spatiale similaire à celle de la FF-OCM, mais à une profondeur supérieure atteignant 300 μm. / Optical coherence microscopy (OCM) is a technique for tomographic imaging based on white light interferometry, making it possible to image biological media with micrometer-scale spatial resolution. OCM is particularly well-suited to dermatological imaging, especially skin cancer diagnosis, since it provides images that are similar to histological images without the need for biopsy.This PhD thesis focuses on the development of OCM for skin imaging, with the aim of providing a compact, in vivo imaging tool for the dermatologist, capable of acquiring structural and functional images of the skin.A compact, full-field OCM (FF-OCM) system illuminated by a white LED was first developed, making it possible to obtain tomographic images at an ultra-high resolution (0.7 μm × 1.8 μm), up to ∼200 μm in depth within the skin. Using a high power LED, in vivo skin images could be obtained.Using this FF-OCM setup, functional imaging methods for blood flow mapping (angiography) were implemented. Four methods, based on temporal or frequency analysis of the interferometric signal, phase images or amplitude images, have been shown to be able to image intralipid flow within a model blood capillary.Functional polarimetric imaging has also been explored in FF-OCM. Contrast optimization in polarimetric images has been obtained by modifying the polarizing components of the conventional polarization sensitive FF-OCM setup depending on the sample to be imaged. This method has been tested on a simple polarizing sample.Finally, a new OCM method, line-field confocal OCM (LC-OCM), has been studied. The goal here was to develop a system capable of imaging the skin in vivo, with a tissue penetration depth greater than what is possible for FF-OCM. This system, which combines interferometric filtering and confocal filtering, makes it possible to obtain in vivo skin images in vertical and en face slices, with a spatial resolution similar to that of FF-OCM, but with a greater penetration depth of 300 μm.
3

Modélisation numérique et caractérisation des défauts dans les miroirs multicouches en vue de leur application en imagerie X cohérente. / Numerical modelling and characterization of multilayer mirror defects for coherent X-ray imaging applications

Piault, Pierre 20 June 2019 (has links)
Les miroirs multicouches trouvent de nombreuses applications utilisant les rayons X produits par les synchrotrons et les lasers à électrons libres et doivent relever de nouveaux challenges apparus avec l'amélioration de ces sources de rayonnement. Pour étudier les causes des contrastes d'intensité produits dans le faisceau réfléchi, des mesures expérimentales et une modélisation numérique ont été effectuées.Plusieurs méthodes d’analyse de la structure des multicouches et du front d’onde réfléchi par un miroir multicouches ont été mises en œuvre sur la ligne de lumière BM05 de l'ESRF. Les méthodes de mesure de 'Rocking Curve Imaging' et 'theta/2theta Imaging' ont été appliquées et adaptées pour la première fois aux miroirs multicouches. Des mesures du front d'onde réfléchi par une multicouche ont aussi été effectuées à partir des techniques d’holographie et de tavelure en champ proche. Les résultats obtenus permettent de mieux comprendre les effets de phase produits par les multicouches ainsi que leurs origines et de reconstruire la topographie de défauts de hauteur d'un miroir multicouches par l'utilisation du modèle numérique développé durant cette thèse.Un modèle numérique basé sur les équations de Takagi-Taupin a été modifié pour tenir compte de défauts dans la structure multicouches d'un miroir. Des simulations de défauts simples ont été effectuées afin de caractériser les performances et les limites du modèle numérique. La propagation et la cohérence de faisceau réfléchi ont été simulées. Les résultats expérimentaux et simulés ont alors permis de montrer que les défauts de hauteur dans la structure multicouches des miroirs constituent la cause principale des contrastes d'intensité. Les simulations effectuées conduisent à conclure que les effets induits par les défauts de hauteur dans une multicouche sont analogues aux effets de phase produits par ces même défauts de hauteur sur une surface réfléchissante.Ces modèles et ces simulations peuvent être utiliser pour spécifier les caractéristiques des défaut de hauteur qui minimise la production du contraste d'intensité. Les techniques expérimentales développées permettront de caractériser avec les rayons X les futures multicouches. / Multilayer mirrors find numerous X-ray applications in synchrotron and X-rays free electron lasers. These multilayers optical devices must take up new challenges raised with the upgrade these radiation sources. To study the origin of intensity contrast in reflected beam, experimental measurements and numerical modeling were performed.Several techniques for multilayer structure charactérization have been implemented at the ESRF beamline BM05. Measurements methods based on 'Rocking Curve Imaging' and 'theta/2theta' Imaging were performed and applied for the first time to multilayer mirrors. Measurements of the wavefront reflected by multilayers were performed using holography and near field speckle techniques. The results obtained allowed a better understanding of the phase effects induced by multilayer reflection of their origin and to reconstruct the topography of the height defects within a multilayer mirror using the numerical model developped in the course of this PhD thesis.A numerical model based on Takagi-Taupin equations was modified to account for defects present in the multilayer mirror structure. Simulations for simple defects were performed to evaluate performance and limits of the numerical model. The propagation and the coherence of the reflected beam were simulated. The measurement and simulation results show the main influence of defect heights on the generation of the intensity contrast observed. The simulations also lead to conclude the equivalency phase effect resulting of the same height defects in multilayers mirror structure and reflecting surface.These modelization and simulations results can be usefull to specify defect feature which minimise reflected intensity contrast. The new developped experimental technics will allows X-rays caracterization for next multilayer mirrors.

Page generated in 0.0219 seconds