• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1434
  • 1280
  • 62
  • 41
  • 38
  • 25
  • 24
  • 23
  • 20
  • 17
  • 13
  • 5
  • 3
  • 3
  • 2
  • Tagged with
  • 2907
  • 518
  • 445
  • 417
  • 355
  • 354
  • 354
  • 354
  • 354
  • 301
  • 299
  • 297
  • 290
  • 287
  • 265
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Avaliação microbiológica em sistemas de água de diálise em clínicas especializadas de Curitiba, PR

Figel, Izabel Cristina 16 May 2012 (has links)
Resumo: No Brasil existe um grande número de pessoas que apresentam insuficiência renal crônica e são submetidos a sessões de diálise. A hemodiálise promove a retirada das substâncias tóxicas, água e sais minerais do organismo através de uma máquina, em clínicas especializadas. A contaminação pelos micro-organismos e endotoxinas nos fluídos de diálise é um grave problema em terapia por hemodiálise e pode ser causada pela água usada para preparação do dialisato. A legislação que regulamenta a qualidade microbiológica da água destinada ao processo de diálise no Brasil é a RDC 154 de 2004 da Agencia Nacional de Vigilância Sanitária. O objetivo deste trabalho foi avaliar a qualidade microbiológica da água dos sistemas de diálise de clínicas de Curitiba (PR). Foram realizadas análises de contagem de bactérias eterotróficas por plaqueamento em profundidade (Pour Plate), contagem de coliformes totais e contagem de Pseudomonas aeruginosa pelo método do Número mais provável (NMP/100 mL), conforme descrito em APHA; AWWA; WPCF (2005), concentração de endotoxinas bacterianas pelo método gel-clot (LAL) conforme USP 31 (2008) e a contagem de fungos seguiram as técnicas de plaqueamento em superfície e iltração por membrana. Os fungos isolados foram identificados por macro e micromorfologia e, os fungos dematiáceos foram identificados por sequenciamento de regiões ITS do rDNA. Verificou-se que na contagem de bactérias heterotróficas 95% das amostras analisadas estavam dentro dos limites estabelecidos; para contagem de coliformes totais 100% das amostras estiveram de acordo com a legislação; para ndotoxina bacteriana 85% da água analisada estavam dentro dos padrões; Pseudomonas aeruginosa esteve presente em 4% das amostras. Quanto à presença de fungos 26% das amostras apresentaram eveduras e 58% fungos filamentosos. Foram identificados os gêneros Penicillium spp., Aspergillus spp., Trichoderma spp., Fusarium spp., Acremonium spp., Beauveria spp., Cladosporium spp., Exophiala spp. eRinocladiella spp.. Os fungos dematiáceos estavam presentes em 46% das amostras analisadas, onde 12 isolados da água tratada para diálise e dialisato foram identificados por sequenciamento, sendo encontrados Exophiala pisciphila, Cladophialophora sp., Cladosporium cladosporoides, Rinocladiella atrovirens e Pseudocladosporium sp.. A presença de fungos matíaceos e endotoxinas pode apresentar um potencial patogênico à saúde já debilitada dos pacientes.
112

Diagnóstico da concentração de flúor nos sistemas públicos de água da região de Araçatuba

Daré, Flávio [UNESP] 25 August 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-08-25Bitstream added on 2014-06-13T20:19:10Z : No. of bitstreams: 1 dare_f_me_ilha_prot.pdf: 629829 bytes, checksum: 1000d04e40c95aa883438d835ff4fb18 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Há 60 anos implantou-se a prática de adicionar flúor à água considerada hipofluoretada com finalidades preventivas de preservação da integridade do esmalte dentário. No Brasil, ensaiou-se há 50 anos projeto piloto de fluoretação das águas de abastecimento, culminando com publicação de Lei Federal, que já conta com 30 anos de vigência, obrigando os sistemas públicos de distribuição de água a manterem o teor de flúor em quantidades bem definidas, visando proporcionar o benefício que tal elemento propicia. Este trabalho foi desenvolvido com o objetivo de verificar o atendimento à norma legal sobre fluoretação de água de abastecimento público em 40 municípios da região de Araçatuba (SP). Foram utilizadas 5.157 análises de determinação de teor flúor, realizadas durante um período de 4,5 anos pela Secretaria Estadual da Saúde, órgão encarregado da fiscalização dos sistemas públicos de água. Os dados foram analisados com relação ao tipo de manancial e estrutura dos sistemas de abastecimento, representada pela população dos municípios e tipo de administração. Verificou-se que 51,6% das amostras não atenderam ao padrão de fluoretação. Segundo a estrutura dos sistemas o atendimento foi melhor no grupamento Sabesp (69%), seguido por municípios Grandes (52%)... / Sixty years ago, the practice of adding fluoride to the water considered hypofluorided was adopted with the preventive means of preserving the integrity of the enamel of the teeth. A pilot project of the water supply fluoridation was tested in Brazil 50 years ago, culminating with the Federal law publication which counts on 30 years of validity. The public services of water distribution were made to keep the fluoride content in well-defined quantities aiming to promote the benefit which this element provides. This work was developed with the objective of verifying the obedience to the legal norm about fluoridation of the public water supply in 40 districts in the region of Araçatuba (SP). 5,157 analysis of fluoride content examination were processed during the period of 4,5 years by the Health Department of São Paulo State (Secretaria Estadual da Saúde), the government body responsible for the inspection of the public water system. The data were analyzed based on the type of water source and the structure of the water supply system, according to the populational size of the districts and the ways of managing. It was verified that 51,6% of the sampling did not obey the fluoridation standard. According to the structure of systems the obedience was... (Complete abstract click electronic access below)
113

AvaliaÃÃo da qualidade de Ãgua do reservatÃrio GaviÃo utilizando macroinvertebrados como bioindicadores.

Talitha Rochanne Alves Abreu da Costa 18 October 2013 (has links)
nÃo hà / A preocupaÃÃo com processos que causam degradaÃÃo da qualidade dos recursos hÃdricos e dos ecossistemas aquÃticos tem se acentuado, principalmente, devido a enorme quantidade de poluentes e novas substÃncias que adentram nesse meio. Objetivou-se, com este trabalho, ampliar o conhecimento sobre a comunidade de macroinvertebrados aquÃticos do reservatÃrio GaviÃo em Itaitinga (CE), onde ocorre a captaÃÃo das Ãguas para o sistema de abastecimento de Ãgua da regiÃo metropolitana de Fortaleza e avaliar como os organismos respondem à disposiÃÃo dos resÃduos da ETA GaviÃo, utilizando o Ãndice BMWPâ. As coletas foram realizadas mensalmente, empregando um coletor do tipo Surber (500 Âm de abertura de malha) no perÃodo de outubro 2012 a maio de 2013. Foi coletado um total de 1.621 espÃcimes, distribuÃdos em 23 taxa. Mollusca foi o grupo dominante e frequente e Insecta apresentou maior riqueza. Segundo o Ãndice BMWPâ, verificou-se que o reservatÃrio GaviÃo encontra-se com suas Ãguas em qualidade duvidosa. / Concerns with the processes that cause water resources and ecosystem degradation are on the rise, especially because of large amounts of pollutants and substances that enter this medium. This study aimed to evaluate water macroinvertebrate communities in tanks used for water collection for urban use and to assess how organisms respond to waste generated in the water treatment plant. We collected a total of 1,621 specimens, distributed into 23 taxa. Mollusca was the dominant and frequent group and insecta was the most abundant. Based on feeding mode, there are more predatory organisms in relation to scrapers. We found no eudominant families. By using the BMWPâ score we verified that water quality in the âGaviÃoâ reservoir is questionable.
114

Lei 6.050 : 25 anos de legislação sobre a fluoretação da agua em sistemas de abastecimento publico no Brasil

Yokoyama, Ricardo Takumi 02 September 2001 (has links)
Orientador: Maria da Luz Rosario de Sousa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T00:06:39Z (GMT). No. of bitstreams: 1 Yokoyama_RicardoTakumi_M.pdf: 6205468 bytes, checksum: c0c2f546c57290406e420ed226410f41 (MD5) Previous issue date: 2001 / Resumo: Apesar de Dean ter definido em 1941 a concentração ótima de íon flúor na água de sistema de abastecimento, somente em 1974 esta medida tomou-se obrigatória no Brasil através da Lei NQ6.050. Os objetivos deste trabalho foram descrever o histórico da legislação sobre a fluoretação da água em sistema de abastecimento público no Brasil, além de verificar o conhecimento apresentado pelos coordenadores de saúde bucal a respeito desta legislação e identificar as dificuldades encontradas pelos mesmos para obedecer tais determinações legais. Para descrever o histórico utilizou-se as bases de dados MEDLlNE, Lilacs, BBO e Lex; para verificar o conhecimento aplicou-se um questionário, tendo a participação de 23 dos 25 coordenadores de saúde bucal e para identificar as dificuldades encontradas por estes profissionais realizou-se entrevistas com funcionários responsáveis pelo setor de odontologia e de vigilância sanitária da DIR XV e consultou-se informações oficiais desta instituição a respeito da fluoretação da água. Os dados coletados foram submetidos ao teste exato de Fischer bi-caudal e ao teste de proporções entre repostas corretas/respostas incorretas, ambos com 'INFINITO¿=0,05. Apesar de 87,0% da amostra ter afirmado que existe uma legislação que regulamenta a adição de compostos fluoretados na água em sistemas de abastecimento público e 69,6% ter respondido ser procedimento obrigatório, somente 34,8% declarou que conhecia a lei ou que já havia lido algum artigo a respeito. Apenas 21,7% dos coordenadores de saúde bucal afirmaram que a fiscalização do teor de fluoretos na água em sistema de abastecimento público era uma responsabilidade da vigilância sanitária e 43,5% sabiam qual era o valor da concentração ótima de flúor na água. Constatou-se que não existiu associação entre o fato do profissional ter lido a legislação com uma maior porcentagem de respostas corretas para questões sobre a responsabilidade de fiscalizar o teor de flúor na água (p=0,30), sobre o valor da concentração ótima de flúor na água (p=0,69) e sobre os fatores interferentes na quantidade de compostos fluoretados adicionados na água a fim de se obter esta concentração (p=1,00). Não se observou diferença estatisticamente significante nas questões avaliadas que comprovassem um maior conhecimento do grupo que leu a legislação (p=0,1808, p=0,6449 e p=0,8788, respectivamente). Os dados levantados no presente estudo apontam para um conhecimento insatisfatório acerca das questões formuladas e seria importante o domínio do assunto para não comprometer a maior medida preventiva de saúde pública na odontologia, uma vez que não se tendo o domínio do assunto perde-se em poder de cobrança ao correto emprego das medidas e normas estabelecidas nesta / Abstract: Optimum dosage of fluoride in public water supplies was defined by Dean (1941). However, this method was only made compulsory in Brazil in 1974, through the law No. 6.050. The aims of this study were: (I) to present a chronicle of the history of legislationon fluoridation in public water supplies in Brazil;(II) to verifythe knowledge of oral health coordinators about this legislation; and (III) to identify the difficulties encountered by such coordinators to obey the legislation. The history was studied using MEDLlNE, Lillacs, BBO and Lex. The knowledge was verified through a questionnaire; sample size was 23. The difficulties were identified through interviewing officials responsible for the department of dentistry and sanitary vigilance of DIR XV.Fischer test was used, with 'INFINITO¿=0.05 and the proportion test between correct answers/wrong answers for two groups. Although 87% answered that there is a law about fluoridation of public water supplies and 69,9% answered it must be compulsory, only 34,8% said they had read the legislation. Only 21,7% knew that the fiscalization of fluoride ion in the water must be made by sanitary supervision and only 43,5% knew the correct optimum level of fluoride ion in water supplies. It was verified that there was no association between the fact that an oral health coordinators stated that he or she had read the legislation and correct answers to questions about who must supervise the ion fIuoride levei in the water supplies (p=0,30),about the optimum levei of fIuoride ion (p=0,69) and about the interference factor in this concentration (p=1,00). It was not obselVed a statistically significant difference in the evaluated questions to prove a greater knowledge of the group who had read the legislation (p=0,1808, p=0,6449 and p=0,8788, respectively). Results indicate an unsatisfactory knowledge about the questions. It would be important that oral health coordinators knew the legislation perfectly. Otherwise they will obviously be unable to demand the correct employment of the public health preventive measures and standards established in law / Mestrado / Mestre em Odontologia Legal e Deontologia
115

Caracterización del potencial hídrico xilemático a mediodía en diez especies frutales

Valenzuela Sauer, Heiny Andrés January 2011 (has links)
Memoria para optar al título profesional de Ingeniero Agrónomo Mención Fruticultura / La presente investigación se realizó durante las temporadas 2007/2008 y 2008/2009 en el huerto experimental del Campus Antumapu de la Universidad de Chile (33º 40´ de latitud Sur, 70º 38´ de longitud Oeste y 420 m.s.n.m.), en 10 especies frutales (Malus x domestica var. Gala, Prunus armeniaca var. Dina, Modesto y Patterson, Pyrus communis var. Beurré Hardy, Prunus dulcis var. Price, Nonpareil y Carmel, Prunus persica var. Pomona, Kakamas y Phillips Cling, Prunus persica var. Nectarina ‘Rio Oso’, Prunus avium var. Brooks y Lapins, Prunus domestica var. D’Agen, Prunus salicina var. Santa Rosa y Black amber, Juglans regia var. Serr, Chandler y Sunland), con el objeto de caracterizar el potencial hídrico xilemático (Ψx) a mediodía (entre las 12:00 y 16:00 horas) en condiciones de no limitación hídrica, con una bomba Schollander. Se evaluó el Ψx en árboles recientemente regados bajo diferentes condiciones de temperatura y humedad ambiental. Adicionalmente, se determinó el efecto de la ubicación de las hojas dentro del árbol sobre el Ψx y el tiempo requerido, en cada especie frutal, para alcanzar el equilibrio del Ψh (potencial hídrico de la hoja) con el Ψx. El Ψx de cada especie frutal fue singular, difiriendo entre especies; la lectura en hojas de la zona baja y media del árbol, y expuestas a la sombra son más homogéneas; el tiempo mínimo de equilibrio para medir el Ψx varía desde 15 minutos (peral, almendro, manzano y damasco) hasta 60 minutos (cerezo, nectarina, duraznero, nogal, ciruelo europeo y ciruelo japonés), luego de bloqueada la transpiración de las hojas expuestas a la sombra. / A research was performed during seasons 2007/2008 and 2008/2009 in an experimental orchard located in Campus Antumapu, Universidad de Chile (33 º 40 ' S, 70 º 38 ' W; 420 m.a.s.l.). Ten fruits species in the orchard were used (Malus x domestica var. Gala, Prunus armeniaca var. Dina, Modesto y Patterson, Pyrus communis var. Beurré Hardy, Prunus dulcis var. Price, Nonpareil y Carmel, Prunus persica var. Pomona, Kakamas y Phillips Cling, Prunus persica var. nectarine ‘Rio Oso’, Prunus avium var. Brooks y Lapins, Prunus domestica var. D’Agen, Prunus salicina var. Santa Rosa y Black amber, Juglans regia var. Serr, Chandler y Sunland), with the aim of characterizing midday stem water potential (between 12:00 and 16:00 hours) of recently irrigated plants using the pressure chamber (PMS, instrument model Pump up). Water potential was measured under different temperature and humidity conditions (also recorded). In addition, the effect of leaf location on the tree and the time needed to achieve the balance between Ψl (leaf water potential) and Ψx (xylem water potential) were determined. Results showed that stem water potential differs according to fruit tree species; leaves located in the low and a middle zone of the tree and exposed to the shade were better to measure Ψx; the time required to balance Ψ varies from 15 minutes (pear, almond, apple and apricot tree) to 60 minutes (cherry, nectarina, peach, walnut, european and japanese plum tree), after blocked the transpiration in leaves exposed to shade.
116

Ciencia ciudadana: Oportunidad para mejorar la gestión de los recursos hídricos en los Andes (Video)

Ochoa, Boris; Gil, Junior 24 October 2016 (has links)
Conferencia realizada en el marco de la Semana del Acceso Abierto Perú, llevada a cabo del 24 al 26 de Octubre de 2016 en Lima, Peru. Las instituciones organizadoras: Universidad Peruana de Ciencias aplciadasd (UPC), Pontificia Universidad Católica del Perú (PUCP) y Universidad Peruana Cayetano Heredia (UPCH). / Conferencia que aborda las actividades desarrolados en los Andes Peruanos en relación a los recursos hídricos.
117

Dureza en aguas de consumo humano y uso industrial, impactos y medidas de mitigación. Estudio de caso: Chile

Neira Gutiérrez, Marco Antonio January 2006 (has links)
No description available.
118

Propuesta de mejora en el proceso productivo en la empresa Industrias y Derivados S.A.C. para el incremento de la productividad

Morales Razuri, Carlos Alberto January 2016 (has links)
En el presente trabajo de investigación se analizó la mejor propuesta, adaptada a la realidad empresarial, que contribuya a la mejora continua de la producción de agua de mesa embotellada, centrada en la presentación de bidones de 20 litros. Este análisis consistió en ejecutar un diagnóstico general para la identificación de los problemas en los procesos tanto productivos como de apoyo; resaltando que, el principal inconveniente que repercute en la empresa es la cantidad creciente de pedidos no atendidos resultantes de su deficiente planificación y gestión. A partir de ello, se describen las operaciones realizadas para la obtención de su producto final, diagrama de recorrido inicial, los indicadores de producción, como por ejemplo: productividad de materia prima, productividad de mano de obra, eficiencia física, eficiencia económica, capacidad, utilización, etc. Tras ello, también se realiza un análisis, respaldado por el diagrama de Ishikawa, que enumera problemas desde diversas perspectivas, encontrando algunos como: pérdida de materia prima, falta de planificación en la producción, personal no calificado; los cuales, a su vez, contribuyen a la reducción de la productividad al no poseer un sistema integral orientado a la mejora continua. Todo ello, en conjunto, determina que la Empresa debe considerar implementar mejoras que aumenten su capacidad de producción y con ello su rentabilidad. Identificado el problema principal, se recurre al análisis de movimientos, con la finalidad de reducir el tiempo de ciclo del proceso de lavado, el cual constituía un cuello de botella, al empalmarse con el problema antes mencionado, acerca del personal no calificado a desempeñar ciertas labores. Acorde a lo anteriormente descrito, se propone un plan de capacitación para el personal en general, que apoye en la estandarización de los procesos, que, a mediano plazo incrementarán la producción de la empresa de 15 unidades por hora a 22 unidades por hora, al contar con el recurso humano apto para las funciones a realizar. Además, se presenta un nuevo diagrama de recorrido, buscando la eliminación de las operaciones de transporte, pues estas no generan ningún valor esencial al proceso productivo principal, logrando reducir tiempos en el proceso global. Al ejecutar, dichas mejoras, se calculan nuevos indicadores de producción, los cuales fueron comparados con los anteriormente diagnosticados, logrando establecer que, aumenta la productividad de materia prima a 83,33%, y se disminuye el cuello de botella de 4 minutos a 2,72 minutos. Finalmente, se evaluó la propuesta, en un análisis costo-beneficio, obteniendo como resultado una VAN de 1 402 440 y una TIR de 58%, señalando la factibilidad de la implementación de la mejora; con la única finalidad de lograr el incremento de la productividad para el cumplimiento de todos los pedidos, repercutiendo en el prestigio y confianza de la Empresa, así como también en su rentabilidad. / Tesis
119

Eletrodos de superfície microtexturizada para a obtenção de hidrogênio eletrolítico

Kleinke, Maurício Urban, 1958- 24 July 1984 (has links)
Orientador: Mario Antonio Bica de Moraes / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-16T11:08:29Z (GMT). No. of bitstreams: 1 Kleinke_MauricioUrban_M.pdf: 1939939 bytes, checksum: 73422b1d27cf3ba21fc5f26b9c1ad2cd (MD5) Previous issue date: 1984 / Resumo: Foram preparados e caracterizados eletrodos para a reação de evolução de hidrogênio e oxigênio a partir da eletrólise da água. Os eletrodos utilizados foram de níquel recoberto por um filme de politetrafluoretileno (PTFE) microtexturizado. O filme de PTFE, previamente depositado no eletrodo, foi texturizado através de um plasma reativo de oxigênio formado por rádio-frequência, utilizando como máscara um filme globular de estanho. O resultado da corrosão é a formação de uma estrutura de "dedos" de PTFE normais à superfície do eletrodo de níquel. Os eletrodos com uma estrutura texturizada em sua superfície apresentam urna diminuição nos valores dos sobrepotenciais anódicos e catódicos (quando comparados aos obtidos no caso do eletrodo de níquel polido). A morfologia dos eletrodos texturizados foi observada através de microscopia eletrônica de varredura e a caracterização eletroquímica dos eletrodos feita através do estudo das curvas de Tafel. Foi observada uma correlação entre a eficiência dos eletrodos e a estrutura morfológica de sua superfície. A questão da redução da área efetiva dos eletrodos devido à formação de bolhas na superfície foi discutida e calculada / Abstract: Electrodes for hydrogen and oxygen evolution for water electrolysis have been prepared and characterized. The nickel electrodes were covered with a microtextured polytetrafluoroethylene (PTFE) film. The textured film were obtained by etching the PTFE layer, previously deposited on the electrode, by a radio-frequency oxygen plasma, using a tin globular film mask. The resulting electrode structure is a nickel surface covered by a very large density of PTFE "hills" (or "fingers") pointing perpendicularly to the electrode surface. The PTFE fingers have shown to reduce both cathodic and anodic electrode overvoltages (with respect a polished nickel electrode). The morphology of the textured film is observed by means of scanning electron microscopy and the electrochemical performance of the electrodes is characterized by their Tafel plots. A correlation between electrolytic activity and electrode surface structure was observed. The problem of gas bubble formation and its effect on reduction of the electrode active surface area is discuss ed and evaluated. / Mestrado / Física / Mestre em Física
120

Controle de kicks em aguas profundas

Negrão, Alvaro Felipe 17 July 2018 (has links)
Orientador : Eric Edgar Maidla / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-17T00:35:23Z (GMT). No. of bitstreams: 1 Negrao_AlvaroFelipe_M.pdf: 1521437 bytes, checksum: 2f2eef233e763adc74d9a21f74bfc747 (MD5) Previous issue date: 1989 / Resumo: Um kick, por definição, é um influxo indesejável de fluído do reservatório portador de hidrocarbonetos para o interior do poço. Este trabalho faz uma modelagem de circulação de kick de gás em plataforma flutuante localizada em águas profundas, utilizando correlações para fluxo bifásico gás-líquido vertical, e na qual as propriedades da fase gasosa são determinadas através da pressão média da região bifásica. Para a região monofásica (fluido de perfuração) são utilizados os conceitos do modelo reológico binghamiano. A partir da variação da pressão no espaço anular do poço que está sendo perfurado, determina - se uma vazão de circulação de fluido de perfuração considerada ideal para a circulação do kick, possível de ser executada pelas bombas de perfuração disponíveis, em função da profundidade do mar na região. O modelo prevê ainda as pressões na parte inferior do último revestimento descido, indicando se estas serão ou não superiores a resistência do solo na parte não revestida do poço, possibilitando que o controlador do poço tenha em mãos todos os problemas que afetarão o controle do poço com antecedência / Abstract: Not informed / Mestrado / Mestre em Engenharia de Petróleo

Page generated in 0.0309 seconds