• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 622
  • 203
  • 140
  • 119
  • 66
  • 61
  • 23
  • 19
  • 16
  • 14
  • 10
  • 5
  • 4
  • 4
  • 4
  • Tagged with
  • 1511
  • 715
  • 518
  • 318
  • 230
  • 230
  • 228
  • 205
  • 188
  • 162
  • 161
  • 146
  • 144
  • 142
  • 139
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Application of the analogue computer technique in transient stability studies of power systems.

Ng, Nam. January 1970 (has links)
Thesis--M. Sc. (Eng.), University of Hong Kong. / Mimeographed.
162

Design och konstruktion av handhållet instrument för mätning av ljusintensitet

Gustafsson, Simon January 2015 (has links)
Projektets mål var att utforma och konstruera ett mätinstrument för att upptäcka variationer i ljusintensitet. Uppdraget gavs av avdelningen för fasta tillståndets elektronik på Ångströmlaboratoriet i Uppsala. Instrumentets tänkta användningsområde är att undersöka om avdelningens testuppställningar för belysning av solceller levererar en homogen ljusintensitet. Genom att placera instrumentet på olika positioner under ljuskällan ska eventuella avvikelser i intensiteten kunna avläsas. Kraven på instrumentet var batteridrift och att det skulle vara handhållet. Vidare var det önskvärt att mätvärdet representerades med en analog visare, där mätintervallet skulle gå mellan 800 och 1200 W/m2. Efter litteraturstudier och informationssökning utfördes simuleringar i programmet LTSpice parallellt med prototypframtagning i lab. Instrumentet utformades med en fotodiod, vars ström omvandlas till en proportionell spänning via en transimpedansförstärkare. Denna spänning skalas sedan upp av ett differentialförstärkarsteg för att uppnå önskat intervall och känslighet. En konstant spänning subtraheras i differentialsteget för att mätaren ska ge utslag först över 800 W/m2. Spänningen läggs till sist över en analog amperemeter. I och med fotodiodens förmåga att ge ström proportionell mot ljusintensiteten erhölls linjära samband genom hela kretsen. Projektet kunde inte slutföras inom tidsramen då varken kretskort eller hölje hann konstrueras. En fullt fungerande prototyp på kopplingsdäck blev dock klar. Vidare är alla beräkningar och komponentval gjorda och dokumenterade i rapporten. Med andra ord borde instrumentet utan problem kunna konstrueras utifrån denna rapport.
163

High-performance [delta sigma] analog-to-digital conversion

Tsang, Robin Matthew, 1979- 07 September 2012 (has links)
This dissertation is about a new [delta sigma] analog-to-digital converter that offers enhanced quantization noise suppression at low oversampling ratios. This feature makes the converter attractive in applications where speed and resolution are simultaneously demanded. The converter exploits double-sampling for speed, and takes advantage of a new loop-filter to pin down passband quantization noise. A proto-type is fabricated in 0.18-[mu]m CMOS and tested. Results show that at 200-MS/s, the converter achieves an effective number of bits (ENOB) of 12.2-b in a 12.5-MHz signal band while consuming 89-mW from a 1.8-V supply. Using a common performance metric that takes into account of ENOB and signal bandwidth, the prototype outperforms all previously-reported IEEE switched-capacitor [delta sigma] modulators. / text
164

Design of a low-power interface circuitry for a vestibular prosthesis system

Toreyin, Hakan 21 September 2015 (has links)
The human vestibular system is responsible for maintaining balance and orientation, and stabilizing gaze during head motion. Head motion is sensed by vestibular sensors and encoded via the firing rate of vestibular neurons. Vestibular disorders can result in dizziness, imbalance, and disequilibrium. Currently there are no therapeutic options for individuals suffering from bilateral vestibular dysfunction. A potential solution is a vestibular prosthesis (VP). This device serves to replace peripheral vestibular organs by sensing angular motion, detected by semicircular canals (SCCs), and linear head motion, detected by the otolith organs, and selectively stimulating the corresponding vestibular afferents. An ideal VP will not only mimic the patient-dependent vestibular neural dynamics, but also consume low power. In this study, three energy-efficient ways to implement the motion encoding function required in a vestibular prosthesis are presented. Both analog and digital signal processing techniques to implement the vestibular signal processing functions are investigated.
165

A modern hybrid computer interface

Wilkins, Jeffrey Martin, 1944- January 1970 (has links)
No description available.
166

An analog computer Nyquist and Bode plotter

Tobey, Gene Earl, 1937- January 1961 (has links)
No description available.
167

A new high performance computer d-c amplifier

Naylor, Jimmy Ray, 1941- January 1967 (has links)
No description available.
168

The design of a multiplying digital-to-analog converter for wideband hybrid computation

Eddington, Don Charles, 1945- January 1969 (has links)
No description available.
169

Development of an analog computer noise generator

Manella, John Gust, 1937- January 1961 (has links)
No description available.
170

The use of a D-C analog computer with relay logic to implement an ultrastable feedback system

Simon, Herbert Stanley, 1926- January 1959 (has links)
No description available.

Page generated in 0.0195 seconds