• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 38
  • 8
  • Tagged with
  • 46
  • 24
  • 18
  • 14
  • 12
  • 11
  • 10
  • 10
  • 9
  • 9
  • 9
  • 8
  • 6
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Solcellspolicy avseende Mikroproducenter : Ett förslag på policy avseende solceller hos privata mikroproducenter till Öresundskraft AB

Engdahl, Annelie, Nilsson, Petra January 2014 (has links)
The development of solar photovoltaic (PV) is increasing,with declining module prices and with a strongenvironmental profile. Policies are developed around theworld to achieve the targets set for renewable energy.In Helsingborg, the local power company Öresundskraft isworking with solar PV to achieve the goals of the city.With their vision: - Energy for a Better World and Powerfor the Region, their work with developing the local solarPV market is continuing and the next step is to create asolar PV policy. Today their offer is 1 SEK/kWh for theexcess electricity delivered to the grid.It turns out that compensating the customer is a vitalpolicy and it has to be dynamic to follow the decisions ofpolitics. The same survey shows indeed, thatenvironmental and technical part is of interest. Solar PVwill be supported locally to act on environmentalsustainability and locally produced electricity and withthis Öresundskrafts vision will be achieved.
2

SOLPANELERS MÖJLIGHETER, EN AKTUELL RAPPORT FÖR MONTAGE PÅ FASTIGHETEN KORNHILL

Larsson, André, Hild-Walett, Dennis January 2012 (has links)
This thesis deals with the possibilities of installing solar panels on a property, the building is owned by Kornhillschurch and called Kornhill. The owners of the property wanted to learn more about potentials for installation of solar panels on the property, therefore we described different types of solar cells and solar cells essential function to generate electricity in the report. Different factors that are limiting the generated energy are mentioned. An investigation of the property’s potential has been made in order to consider different designs. When sites that were considered suitable for solar cells were selected, different design options were made, one for each site. Then a number of financial calculations on the dimensioned plants were made to see if each plant will be profitable.
3

Karaktärisering av solcellsmoduler : en fördjupning i solcellsteknik och metoder för karaktärisering

Åström, Sara, Jorlöv, Josefine January 2013 (has links)
Sveriges Tekniska Forskningsinstitut, SP, har nyligen investerat i en pulsande solsimulator för mätning och karaktärisering av solcellsmoduler. I följande rapport har en jämförelse mellan mätresultaten från den nya pulsande solsimulatorn och SP:s befintliga pulsande solsimulator genomförts. Samtliga mätningar har genomförts på fyra olika solcellsmoduler; två solcellsmoduler av typen CIS och två solcellsmoduler av typen kristallint kisel. Vi har även genomfört praktiska mätningar för att se vilka omgivande faktorer som påverkar mätresultaten från den nya solsimulatorn. De omgivande faktorerna bestod av omgivningsljus i form av takbelysning, reflektioner i den nya solsimulatorn och nedsmutsning av detektorcellen. Resultatet visar på en avvikelse mellan de uppmätta värdena i den nya och den befintliga solsimulatorn, där flertalet av mätvärdena i den befintliga solsimulatorn är högre. Troligen beror detta på att mätningen i den befintliga solsimulatorn sker vid en högre irradiansnivå än vad standarden säger. Vidare visar resultatet att det finns omgivande faktorer som påverkar mätresultaten från den nya solsimulatorn. Av de undersökta faktorerna är det nedsmutsning av detektorcellen som uppvisar den största påverkan på mätresultaten. / Sveriges Tekniska Forskningsinstitut, SP, has recently invested in a pulsed solar simulator to measure and characterize photovoltaic modules. The following report investigates the differences in the analysis between the new solar simulator and SP's existing pulsed solar simulator. All measurements have been performed on four different solar modules, two solar modules of type CIS and two solar modules of type crystalline silicon. We have also carried out practical measurements to see which environmental factors that affect the analysis from the new solar simulator. The surrounding factors consisted of ambient lighting, reflections from the new solar simulator and soiling of the monitor cell. The results show a difference between the quantified values of the new and existing solar simulator, where most of the measurements in the existing solar simulator are higher. The differences are probably due to measurements being made at a higher irradiance level than according to the standard. Furthermore, the results show that there are environmental factors affecting the analysis from the new solar simulator; a soiled monitor cell have the greatest influence on the outcome.
4

Solcellssystem och dess påverkan på lågspänningsnät i tätort / Photovoltaic systems and its impact on low-voltage grid in urban areas

Norling, Johan January 2014 (has links)
Med ett statligt investeringsstöd och ett kommande förslag på skattereduktion för inmatning av förnybar el på elnätet, spås en fortsatt stor ökning av nätanslutna solcellsanläggningar. Det fortsatt sjunkande priset på nyckelfärdiga solcellssystem på grund av ökad konkurrens och massproduktion ger ytterligare anledning att tro på ett ökat intresse.Syftet med rapporten är därför att, utifrån fortsatt förväntad ökning av nätanslutna anläggningar i tätort, undersöka hur dessa påverkar spänningen i elnätet vid både enfasig som trefasig anslutning samt hur belastningsförlusterna påverkas vid ändrad effektriktning. Målet är att resultatet ska kunna ge elnätsbolaget en bra grund för vidare utredning.Den standard som ligger till grund för utredningen är SS-EN 50160 som behandlar spänningens egenskaper i elnät för allmän distribution. Från den hämtas krav på spänningens nivå samt tillåten spänningsobalans i nätet och utöver dessa används rekommendationer från rapporten MIKRO - anslutning av mikroproduktion till konsumtionsanläggningar från Svensk Energi.Programvara som används för att genomföra simuleringar och beräkningar av nätanslutna solcellssystem är dp-Power från företaget Digpro. Däri kan befintligt nät och dess kunder få solcellsanläggningar anslutna enfasigt eller trefasigt och nätberäkningar utföras med olika märkeffekt och effektfaktor. Mätarställningar för året 2013 har bearbetats för att ta fram en lägsta effekt under en timme, med målet att få fram den dag på året då lägst förbrukning sker.Fem driftscenarion utarbetats. Tre scenarion behandlar 3,5 kW enfasig anslutning där inkoppling sker på samma fas och under samma gruppledning, samma fas men olika gruppledningar samt ett scenario där varje solcellsanläggning delges en specifik fas i ett försök att uppnå symmetri och anslutning sker gruppledning för gruppledning. De två återstående gäller trefasig anslutning där första scenariot gäller en märkeffekt på 3,5 kW och varje gruppledning fylls i en bestämd ordning och sist används en märkeffekt på 8 kW med liknande val av inkopplingsmetod.Resultatet visar på tidiga problem vid anslutning av enfasiga solcellsanläggningar. I första scenariot sker en otillåten spänningsnivå i en anslutningspunkt redan efter fem anslutna anläggningar. Resterande enfas scenarion visar även de på problem men inte i lika stor utsträckning. Trefasig anslutning ger desto bättre resultat, alla kunder i området kan ansluta.Den viktigaste slutsatsen man kan dra är att enfasig anslutning av solcellsanläggning inte rekommenderas. Även om man försöker delge en specifik fas för att försöka skapa symmetri, kan det komma att orsaka problem i ett tidigt skede. Utförda driftscenarion påvisar även ett antal svaga punkter i nätet där spänningsökningen blir kraftigare jämfört med övriga anslutningspunkter. / With government investment aid and a future proposal on a tax relief for the input of renewable electricity on the grid, predicts a continued large increase in grid-connected photovoltaic systems. The continued drop in price for turnkey photovoltaic systems due to increased competition and mass production provides further reason to expect an increasing interest.The purpose of this report is therefore, based on expected continued increase in grid-connected installations in urban areas, to examine how these affect the voltage in the mains at both single-phase and three-phase connection as well as how load losses are affected by the reversed power flow. The goal is that the result should be able to provide power companies a good foundation for further investigation.The standard which form the basis for the investigation is SS-EN 50160 which target the voltage characteristics of electricity grids for general distribution. Based on the standard, requirements on voltage level and allowable voltage unbalance in the grid is retrieved and furthermore the recommendations from the report MICRO - the connection of micro production to consumption facilities from the Swedish Energy is used.Software used to perform simulations and calculations of grid-connected photovoltaic systems is dp-Power from the company Digpro. Inside the program existing grid and its customers may receive photovoltaic plants connected by single-phase or three-phase, and grid calculations can be performed with a variation of rated power depending on the operational scenario. True meter readings for the year 2013 have been processed to produce a highest and lowest power consumption during an hour.Five operating scenarios have been prepared. Three scenarios deals with 3.5 kW single-phase connection, where the connection is made in the same phase and the same feeder cable, the same phase but different feeder cable and a scenario where every photovoltaic system was appointed a specific phase in an attempt to achieve symmetry and connection takes place in one feeder cable at a time. The two remaining covers three-phase connection where the first scenario concerns a rated power of 3.5 kW, and finally a rated output of 8 kW.The results show early problems when connecting single-phase photovoltaic systems. In the first scenario, an unauthorized voltage level occurs in an access point after only five connected appliances. The remaining single-phase scenarios also demonstrate problems but not to the same extent. Three-phase connection provides a much better result and everyone in the area can connect their PV system. The main conclusion to be drawn is that the single-phase connection of PV systems is not advised. Even if you try to assign a specific phase in an attempt to create symmetry, it may come to cause problems at an early stage. Attempted operational scenarios also demonstrates a number of weak points in the grid where the voltage increase will be more powerful compared to other locations.
5

Lokalproducerad el : Solceller och dess inverkan på distributionsnätet / Distributed Generation : Photovoltaic and its Effect on the DistributionNetwork

Wikström, Bengt-Anders January 2014 (has links)
Målet med denna rapport har varit att konstatera den inverkan en stor installerad effekt av lokalproducerad el kan ha på ett landsbygdsnät. Studien har dels baserats på timmätningar från kundernas elmätare men även av elkvalitémätare som monterats vid tre olika platser i det för studien givna transformatorområdet. De platser som valdes var vid transformatorn, i ett kabelskåp mellan de båda produktionsanläggningarna samt vid en kund som är i elnätets periferi. Fokus har lagts på att studera tillfällen när förbrukningen i nätet är mindre än produktionen och även överspänningar. Även om fokus lagts på dessa två fenomen finns en förteckning över andra effekter anslutning av lokalproducerad el kan ha på elnätet. En påtaglig skillnad kan uppvisas för effektflödena i elnätet. Som mest matas nästan 17kW upp på det överliggande elnätet under en tiominutersperiod. Den kund som är belägen längst bort från transformatorn upplever en spänningshöjning när solcellerna genererar el. En jämförelse gjordes vidare mellan två olika elkvalitémätare. Under tre veckors mätintervall uppgick skillnaden mellan dessa endast till 0,13 procent. Spänningsnivåerna hölls inom hela mätperioden inom de gränser som regleras av standarden SS-EN 50160 för samtliga tre mätpunkter.
6

Design och konstruktion av handhållet instrument för mätning av ljusintensitet

Gustafsson, Simon January 2015 (has links)
Projektets mål var att utforma och konstruera ett mätinstrument för att upptäcka variationer i ljusintensitet. Uppdraget gavs av avdelningen för fasta tillståndets elektronik på Ångströmlaboratoriet i Uppsala. Instrumentets tänkta användningsområde är att undersöka om avdelningens testuppställningar för belysning av solceller levererar en homogen ljusintensitet. Genom att placera instrumentet på olika positioner under ljuskällan ska eventuella avvikelser i intensiteten kunna avläsas. Kraven på instrumentet var batteridrift och att det skulle vara handhållet. Vidare var det önskvärt att mätvärdet representerades med en analog visare, där mätintervallet skulle gå mellan 800 och 1200 W/m2. Efter litteraturstudier och informationssökning utfördes simuleringar i programmet LTSpice parallellt med prototypframtagning i lab. Instrumentet utformades med en fotodiod, vars ström omvandlas till en proportionell spänning via en transimpedansförstärkare. Denna spänning skalas sedan upp av ett differentialförstärkarsteg för att uppnå önskat intervall och känslighet. En konstant spänning subtraheras i differentialsteget för att mätaren ska ge utslag först över 800 W/m2. Spänningen läggs till sist över en analog amperemeter. I och med fotodiodens förmåga att ge ström proportionell mot ljusintensiteten erhölls linjära samband genom hela kretsen. Projektet kunde inte slutföras inom tidsramen då varken kretskort eller hölje hann konstrueras. En fullt fungerande prototyp på kopplingsdäck blev dock klar. Vidare är alla beräkningar och komponentval gjorda och dokumenterade i rapporten. Med andra ord borde instrumentet utan problem kunna konstrueras utifrån denna rapport.
7

Solenergiutveckling i Halland

Andersson, Martin, Åhlund, Anton January 2014 (has links)
Idag ökar antalet solenergianläggningar stort i Sverige, framförallt inom solelen. Samtidigt finns det inte någon långsiktig hållbar metod för att statistikföra solenergin. Det finns heller ingen regionsspecifik statistik, något som många svenska län och kommuner är intresserade av. Med bakgrund till detta behandlar arbetet frågor om solenergins utveckling med utgångspunkt för Hallands län, där fokus ligger på statistikinsamling. För att få en god uppfattning om utbyggnaden av solenergi i länet görs en statistiksammanställning av regionens solenergi. Samtidigt läggs förslag på framtida statistikmetoder för att bättre kunna följa solenergins utveckling i framtiden, regionalt såväl som nationellt. En jämförelse med andra län samt Tyskland och Danmark görs för att fånga upp idéer. Jämförelsen visar att Tyskland och Danmark idag har mer utvecklade metoder för statistikinsamling av solel medan de likt Sverige, har begränsad solvärmestatistik. Även en lönsamhetsberäkning för en mindre privat solcellsanläggning gjordes. Det visade sig vara lönsamt om anläggningen får skattereduktion eller investeringsstöd. Utan ekonomisk hjälp är lönsamheten lägre, även om utsikterna kan ändras beroende på elprisutvecklingen. Resultatet av den regionala statistiksammanställningen visar att Halland i början av år 2014 hade 1,6 GWh i årlig energiomvandling för solel respektive 7,3 GWh för solvärme. I länet finns 5,3 W/capita nätansluten solel jämfört med Sveriges 4,2 W/capita, vilket innebär att Halland har 21 % mer installerad effekt än Sverige i genomsnitt. De lämpligaste källorna för insamling av solenergistatistik är energibolag och installatörer där en kombination av dessa två källor ger en stor säkerhet och hög täckningsgrad. Finns bara resurser är detta det bästa alternativet. Rapportering går från dagens manuella metod till ett automatiserat system. En viktig ändring blir att rapportering av lokalisering införs vilket medför att regional statistik enkelt kan sammanställas.
8

Mätdatainsamling för solceller : Uppbyggnad av en mätnings krets för solceller / Collection of measurement data for solar cells : Construction of a measuring circuit for solar cells

Karlsson, Johan January 2021 (has links)
Glava Energy Center har gett mig i uppdrag att skapa ett system som kan hantera mätdatainsamling för solceller. Projektet går ut på att mäta ström och spänning från solceller och sedan skicka denna mätdata till en metrum instrumentlåda som sedan laddar upp datan till deras databas. Med hjälp av ett mikrokontrollerkort och en IC skapas detta system för att hämta data. Datan kollas sedan via python kod för att se så att den stämmer väl med vad som förväntas. Systemet som utvecklats hittar solcellens MPP inom 20 sekunder. Dock tack vare tidsbrist kan inte systemet skapa den analoga signalen på 4-20mA som krävs för att skicka datan till metrum instrumentlådan. Den teoretiska kretsen är färdig men har inte hunnit implementeras. / <p></p><p></p>
9

Konstruktion av en solföljare

Aso Abbas, Ismail, Mosa, Mohammed, Frigui, Mehdi January 2020 (has links)
Då dagens energi till större andel kommer från fossila energikällor som har väldigt stora klimatavtryck så har under de senaste åren förnyelsebara energikällor fått alltmer uppmärksamhet i takt med att dessa energikällors produktionskostnader minskat samt att de blivit mer energieffektiva. Till förnyelsebara energikällor hör bland annat solceller, ett sätt som dessa har gjorts mer energieffektiva på är genom att få dessa följa solen under dagen och därigenom fått namnet solföljare. I denna rapport beskrivs solceller och solföljare, dessutom designas och konstrueras en solföljare utrustad med 4 LDR sensorer, för att jämföra den med en statisk solcell. Med hjälp av en microcontroller (arduino) som får insignal från LDR-sensorerna.Utifrån denna skickas en viss utsignal till två elmotorer, som möjliggör rörelse i vertikal och horisontal led. Konstruktionen som dessa elektriska komponenter satt på bestod av 3D-trycktadelar som var så tunna som möjligt men ändå hållbara. Anledningen är att sänka produktionskostnaderna samtidigt som den ger en högre effekt. Olika servomotorer testades men SG90 passade bäst eftersom den hade liten förbrukning jämfört med andra och ett lägre pris. Sedan jämfördes den utvecklade effekten för tre olika fall, vilka är då den har en, två och inga frihetsgrader. Detta resulterade i att för varje ökad frihetsgrad ökade den utvecklade effekten med ca. 20%. Det bästa resultatet erhölls då solföljaren hade tvåfrihetsgrader, vilket gav en en procentuell ökning på 44,4%relativt en statisk solcell (inga frihetsgrader)
10

Lågspänt likströmsmikronät för effektivisering av solcellsanläggningar

Stellmar, Theodor, Engman, Oskar January 2022 (has links)
The Swedish energy supply has gone from dispatchable energy sources to more intermittent energy. The conversion to renewable sources such as solar and wind power, also the increasing demand caused by electrification of cars creates increasing challenges on today's electricity grid. Today's electricity consumption is an increasing trend, which puts loads on the electricity grid as reducing consumption is one of several solutions.  From 1 January 2022, the ordinance (2007:215) on exemptions from the requirement for a network concession in accordance with the Electricity Act (1997:857) has been amended. Construction of an internal low-voltage grid for energy sharing, also called microgrids, has been permitted. This enables an internal low-voltage network, sharing of energy that is burred underground and not overhead may be built, also to be used without a network concession for private actors to build microgrids. This report looks at the interconnection of photovoltaic systems in a microgrid, which enables the sharing of electrical energy. The aim of the study is to see conditions that are advantageous in applying a microgrid. The survey has been compared in two scenarios. Scenario 1 has four buildings with individual photovoltaic systems. Scenario 2 have the same four buildings but only two photovoltaic systems installed, on houses one and four. Both scenarios are compared with the application of a microgrid. The buildings are based on the planned residential area for Eksta AB in Algusered, Kungsbacka. The study in Algusered shows an increase in self-use and self-sufficiency as well as a reduction in overproduction and CO2 emissions for all facilities. Scenario 2 reduces investment costs by reducing the total installed solar cells.

Page generated in 0.0378 seconds