A Wearable Motion Analysis System to Evaluate Gait DeviationsMartori, Amanda Lynn 01 January 2013 (has links)
A Wearable Motion Analysis System (WMAS) was developed to evaluate gait, particularly parameters that are indicative of mild traumatic brain injury. The WMAS consisted on six Opal IMUs attached on the sternum, waist, left and right thigh and left and right shank. Algorithms were developed to calculate the knee flexion angle, stride length and cadence parameters during slow, normal and fast gait speeds. The WMAS was validated for repeatability using a robotic arm and accuracy using the Vicon motion capture system, the gold standard for gait analysis. The WMAS calculated the gait parameters to within a clinically acceptable range and is a powerful tool for gait analysis and potential concussion diagnosis outside of a laboratory setting.
|
2 |
Feasibility of Wearable Sensors to Determine Gait ParametersSimoes, Mario Alves 01 January 2011 (has links)
A wearable system that can be used in different settings to collect gait parameters on subjects with a mild traumatic brain injury (mTBI) would allow clinicians to collect needed data of subjects outside of the laboratory setting. Mild traumatic brain injuries stem from a number of causes such as illnesses, strokes, accidents or battlefield traumas. These injuries can cause issues with everyday tasks, such as gait, and are linked with vestibular dysfunction [1]. Different wearable sensor systems were analyzed prior to starting this study along with relevant gait parameters associated with mild traumatic brain injury. To monitor gait parameters relevant to mild traumatic brain injury (cadence, torso rate of rotation, head rate of rotation and stride length) a wearable sensor system was selected (APDM Opal Movement Monitor [13]) and compared against the gold standard optical tracking system (Vicon) [2]. A group of ten, 20-27 year old, healthy subjects were used to validate the APDM Movement Monitor system using the Pearson's R correlation value [35]. Subjects were asked to wear the APDM movement monitors in conjunction with the reflective markers of the Vicon system while performing three sessions of gait trials: a normal gait speed, a fast gait speed and a slow gait speed. Using the Pearson's R correlation values, cadence, torso rate of rotation, and head rate of rotation were found to be highly correlated between both systems. The Pearson's R correlations for cadence, torso rate of rotation, head rate of rotation and stride length were 0.967, 0.907, 0.942, and 0.861, respectively. These correlation values suggest the gait parameters relevant to mild traumatic brain injury are highly correlated between both the APDM Movement Monitor system and the Vicon system, and APDM's wearable sensor system was lightweight, portable and less costly than the Vicon system.
|
Page generated in 0.0164 seconds