Spelling suggestions: "subject:"abrasion desistance"" "subject:"abrasion coresistance""
1 |
Interfacial and polymer chemistry of methacrylate based composite materialsKirtley, Neil January 1998 (has links)
No description available.
|
2 |
A material study of insoles : Manufactured using different methodsHermansson, Erik, Marcus, Ekberg January 2019 (has links)
Aim: The aim of this study is to evaluate if additive manufacturing (AM) is an appropriate manufacturing method for insoles in comparison to vacuum forming (VF) and subtractive manufacturing (SM) in regards of material properties such as abrasion resistance. Background: Traditionally insoles are manufactured with either VF or SM. AM has been around for some decades but implementation into orthotic and prosthetic (O&P) business has not been accomplished yet. Therefore, the quality of the products produced with AM must be tested in comparison with traditional methods. Method: A comparison of samples for the mentioned manufacturing methods was done with the help of an abrasion testing machine with the standard ASTM G133. Two samples were produced from each manufacturing method and respectively tested for one and two hours. All the samples were weighed before and after the tests with the help of a four decimal scale. The difference in weight before and after the test and coefficient of friction was evaluated. The weight difference was analyzed to see how much material had been removed from the sample. The percentage of wear loss was calculated for each specific sample, both for one hour and two hours of testing. No statistical analysis could be made due to the limited amount of samples and testing time. Result: No statistically significant could be found for either wear loss or the coefficient of friction as mentioned above. Conclusion: A conclusion whether which material having the best abrasion resistance for respectively manufacturing method could not be drawn due to limited results. This study can be seen as a pilot study where the methodology can be used in further studies. Further research on AM needs to be conducted.
|
3 |
Avaliação comparativa de resinas compostas fluidas em relação a resistência à abrasão (escovação simulada). / Abrasion resistance of flowable resin composites by comparative analysis of simulated toothbrushing.Fernanda Cristina Pimentel Garcia 02 March 2001 (has links)
O presente estudo procurou analisar, através de um teste de abrasão in vitro por escovação simulada, a perda de massa e a alteração da rugosidade superficial em resinas compostas "fluidas" e resinas compostas controles. As marcas comerciais utilizadas foram: Aeliteflo-Bisco (A), Natural Flow-DFL (N), Wave-SDI (W), Flow-It Lf-Jeneric/Pentron (FLf) e Flow-It-Jeneric/Pentron (F). Uma resina composta de partículas híbridas Z100-3M (Z) e uma de micropartículas Silux Plus-3M (S) foram utilizadas como controle. Foram confeccionados 84 corpos-de-prova, de 5mm de diâmetro e 3mm de espessura, sendo 12 para cada marca comercial utilizada. Para o acabamento e o polimento dos corpos-de-prova foram utilizados discos Sof-Lex (3M) nas granulações fina (cor azul média) e superfina (cor azul claro), por tempo médio de 15/20 segundos, para cada granulação, em baixa velocidade. Para os ensaios de abrasão, foi utilizada uma máquina apropriada associada à escova Colgate Classic Infantil (Colgate-Palmolive) de cerdas macias e solução do creme dental, Colgate Proteção Anticáries com MFP (Colgate-Palmolive), diluído em água deionizada na proporção de 1:2. No teste in vitro, foram realizados aproximadamente100.000 ciclos. A determinação do desgaste dos materiais foi verificada pela quantidade de massa perdida após os ensaios, com a utilização de uma balança analítica Sartorius. A rugosidade foi determinada quantitativamente na superfície dos corpos-de-prova, com o auxílio de um rugosímetro Hommel Tester T 1000, comparando a diferença obtida após os testes de escovação e, qualitativamente, por microscopia eletrônica de varredura. Os resultados foram analisados pela variância a um critério ANOVA e pelo Teste de Tukey com p<0,05. Pelo coeficiente de Pearson não foi verificada correlação (r=-0,0296) entre porcentagem de perda de massa e rugosidade de superfície. Os materiais não apresentaram diferenças estatisticamente significantes quanto à alteração de massa, somente quanto à rugosidade superficial. A resina A apresentou a maior alteração de massa, (3,77%), seguida da resina de micropartículas S (3,04%). Em contrapartida, a resina híbrida convencional Z apresentou a menor alteração de massa (1,29%), ficando o restante das resinas "fluidas" com alteração intermediária a estas três resinas. A maior alteração de rugosidade foi verificada para a resina W (1,1720mm), com diferenças estatisticamente significantes em relação às outras resinas testadas: S (0,2749mm), Z (0,2495mm), FLf (0,1597mm), F (0,1217mm), N (0,0620mm) e A (0,0505mm). / This research aimed to assess the wear of flowable resin composites through an in vitro simulated toothbrushing abrasion test. The weight loss and surface roughness analysis were performed using five commercial brands: Aeliteflo, Flow-It, Flow-It Lf, Natural Flow and Wave. Hybrid Z-100 and Microfilled Silux Plus composites have been included as controls. Twelve samples (discs) of each material were prepared with 5mm thickness and 3mm in diameter. The test was performed up to 100.000 cicles with an appropriate machine containing soft bristles tips, dentifrice solution and deionized water in order to simulate toothbrushing. The weight loss was determined by the differences between the initial and final weights ( before and after toothbrushing) using a Sartorius analytical scale. After 5 readings, in a T 1000 Hommel testing machine, the evaluation of surface roughness was obtained by the differences between initial and final means. The analyzed ( ANOVA and Tukey, p< 0,05) results showed that Silux Plus, Flow-it, Wave, Flow-It Lf and Natural Flow had an intermediate weight loss (3,04; 2,70; 2,19; 2,12 and 2,04% respectively). Z-100 exhibited the lowest (1,29%) weight loss, whereas Aeliteflo, the highest (3,77%). Wave showed the highest surface roughness variation (1,1720mm), statistically different from the other groups, which exhibited the following differences: Silux Plus (0,2749mm), Z-100 (0,2495mm), Flow-it Lf (0,1597mm), Flow-It (0,1217mm), Natural Flow (0,0620mm) and Aeliteflo (0,0506mm). Aeliteflo presented the highest weight loss and the lowest surface roughness difference; on the other hand, Wave showed the highest surface roughness difference and an intermediate weight loss when compared with the other tested resins.
|
4 |
Avaliação da resistência à abrasão, microdureza superficial e estabilidade de cor de dentes artificiais de resina acrílica / Evaluation of the abrasion resistance, superficial microhardness and color stability of acrylic resin artificial teeth.Pâmela Carbone Mello 20 December 2007 (has links)
O objetivo deste trabalho foi avaliar in vitro a resistência a abrasão, a microdureza superficial e a estabilidade de cor de dentes artificiais de resina acrílica. Sete grupos (1- Biolux, 2- Trilux, 3- Blue Dent, 4- Biocler, 5- Orthosit-Vivodent, 6- Postaris-Antaris, 7- Gnathostar-Ivostar), compostos de 12 pre-molares superiores de cada fabricante, sendo 6 contra antagonistas metálicos (Ni-Cr) e 6 contra antagonistas de resina indireta (Solidex), foram delineados em um perfilômetro, antes e após serem submetidos ao ensaio de abrasão. A diferença linear entre a primeira e a segunda leitura foi medida com um paquímetro digital (precisao 0,01mm). Após a análise estatística (análise de variância, teste de Tukey-Kramer, nível de significancia em p<0,05), observou-se que houve diferenças estatísticas significantes entre os grupos e que a marca Postaris apresentou os menores valores de desgaste contra ambos os antagonistas (R=2,33±0,91µm e M=1,78±0,42µm). Para a análise da microdureza superficial Vickers, foram utilizados 6 incisivos laterais superiores de cada marca e 3 leituras (terços incisal, médio e cervical) foram feitas com o auxílio de um microdurômetro. As médias de microdureza superficial Vickers foram submetidas a análise estatística (nível de significancia p<0,05) e com os resultados obtidos concluiu-se que o grupo Biolux (22,1±0,91VHN) seguido do Antaris (21,9±1,58VHN), Ivostar (21,1±0,98VHN) e Biocler (21,0±1,80VHN) apresentaram maiores valores de dureza diferenciando-se do Vivodent (19,1±0,99VHN) e Blue Dent (18,9±1,54VHN), menos duros. Para o ensaio de estabilidade de cor foram utilizados 6 incisivos centrais superiores direitos de cada marca comercial (n=42), submetidos ao processo de envelhecimento artificial acelerado. O aparelho de leitura de cor utilizado foi um Espectrocolorímetro Portátil Modelo Color Guide 45/0 (BYK-Gardner, Alemanha). Cada dente teve sua cor lida antes e imediatamente após o ensaio de envelhecimento artificial. Os valores de ΔE foram submetidos a análise estatística com auxílio do programa JMP 5.1 (SAS Institute, EUA) e mostraram que houve diferenças estatisticamente significantes entres os grupos e que apenas a marca Blue Dent (4,37±0,32) apresentou valores de ΔE>3,3 considerado, segunda a literatura, clinicamente inaceitável. Para os grupos que tiveram alterações clinicamente aceitáveis, o grupo Antaris/Postaris teve a maior variação de cor (ΔE=2,73±0,96) e o grupo Biolux apresentou a menor variação de cor (1,39±0,27). Dentro das limitações da metodologia empregada, concluiu-se que o antagonista utilizado (metal ou resina) influencia a escolha do dente artificial, e que os dentes artificiais testados tem comportamentos diferentes quanto a resistência a abrasão, microdureza superficial e estabilidade de cor. / The objective of this work was to evaluate in vitro the abrasion resistance, the superficial microhardness and the color stability of acrylic resin artificial teeth. Seven groups (1-Biolux, 2 - Trilux, 3 - Blue Dent, 4 - Biocler, 5 - Orthosit-Vivodent, 6 - Postaris-Antaris, 7 - Gnathostar-Ivostar), composed of 12 upper premolar for each manufacturer\'s, being 6 against metallic antagonists (Ni-Cr) and 6 against indirect resin (Solidex) antagonists, were delineated in a perfilometer, before and after the abrasion test. The linear difference between the first and the second readings was measured with a digital calliper (0,01mm precision). After the statistical analysis (variance analysis, Tukey-Kramer\'s test, p<0.05), it was observed that there were significant differences among the groups and that the trademark Postaris presented the smallest wear values against both antagonists (R=2,33±0,91µm and M=1,78±0,42µm). For Vickers superficial microhardness, 6 lateral upper incisors of each mark and 3 readings were used (incisal, medium, and cervical thirds) done with the microdurometer. The averages of Vickers superficial microhardness were submitted to the statistical analysis (p<0.05) and the obtained results show that the group Biolux (22,1±0,91VHN) followed by Antaris (21,9±1,58VHN), Ivostar (21,1±0,98VHN) and Biocler (21,0±1,80VHN) presented higher values, differing from Vivodent (19,1±0,99VHN) and Blue Dent (18,9±1,54VHN), less harders. For the color stability test 6 upper right central incisors of each commercial mark were used (n=42), submitted to the accelerated artificial aging process. The apparel for color reading was a Portable Spectruncolorimeter Model Color Guide 45/0 (BYK-Gardner, Germany). Each tooth had his color read before and immediately after the artificial aging. The ΔE values were submitted to the statistical analysis with JMP 5.1 (HEALTHY Institute, USA) software and show that significant differences were found among the groups and that only Blue Dent (4,37±0,32) presented clinically unacceptable values of ΔE (ΔE>3.3). For the groups that had clinically acceptable color alterations, the Antaris/Postaris group had the largest color variation (ΔE=2.73±0.96) and the Biolux group presented to smallest color variation (ΔE=1.39±0.27). Within the limitations of the methodology, was concluded that the antagonist (metal or resin) influence the choice of the artificial tooth, and that the tested artificial teeth have different behaviors for the abrasion resistance, superficial microhardness and color stability.
|
5 |
Estudo da influência das propriedades relacionadas à superfície e à matriz na resistência à abrasão de concretos para pisos / Study on the influence of properties related to the surface and matrix in the abrasion resistance of concrete floorsSilva, Cristina Vitorino da January 2015 (has links)
O desgaste superficial por abrasão é uma manifestação patológica que decorre do atrito entre partículas secas e a superfície do material, causando uma perda progressiva das camadas mais externas da estrutura. Entender esse mecanismo de deterioração e ainda os parâmetros que influenciam a sua ocorrência são preocupações válidas, visto que ele compromete a durabilidade e a funcionalidade de estruturas, tais como pisos de concreto. Além disso, a correção desta manifestação patológica exige gastos elevados com reparo ou substituição do concreto e, dessa maneira, a necessidade de maiores estudos buscando ações mais efetivas na prática é justificada. Neste particular, estudou-se a influência das propriedades relacionadas à matriz e à superfície na resistência à abrasão dos compósitos. Para tanto, alguns fatores que influenciam na qualidade dos concretos empregados em pisos, como o tipo de cimento (CP IV; CP V-ARI), a relação água/aglomerante (0,40; 0,60), o teor de substituição de sílica ativa (0%; 10%) e o tipo de cura (submersa; caixa aquecida) foram avaliados. Os ensaios adotados para estudar a influência das propriedades de massa no mecanismo de degaste foram os de resistência à compressão uniaxial, resistência à tração na flexão e exsudação. Já os ensaios para verificar a influência das propriedades de superfície na magnitude desse mecanismo foram os de dureza superficial, resistência à abrasão, porosimetria por intrusão de mercúrio, microdureza por indentação, análises em microscópio estereoscópico e a digitalização tridimensional à laser. Os resultados encontrados mostraram uma influência estatística significativa do tipo de cimento sobre todas as propriedades avaliadas, sendo que o cimento de alta resistência inicial apresentou melhor desempenho em comparação ao cimento pozolânico, considerando uma mesma idade de análise (63 dias). Além disso, verificou-se uma influência estatística significativa da relação a/agl no comportamento dos concretos, onde a relação a/agl 0,6 aumentou os índices de desgaste das amostras em relação as de referência (a/agl 0,4), conforme esperado. Quanto ao tipo de cura, os compósitos curados de forma submersa apresentaram os melhores resultados frente ao desgaste superficial comparando-se àqueles mantidos na cura em caixa aquecida. Finalmente, analisando o teor de substituição de sílica ativa, observou-se que a substituição de 10 % sobre a massa de cimento proporcionou acréscimos estatisticamente significativos na resistência à abrasão das amostras com menor relação a/agl; somando-se a isto, a presença da sílica minimizou o efeito da cura em caixa aquecida na camada superficial das amostras de concreto submetidas ao desgaste. Concluindo, a resistência à abrasão dos concretos mostrou ter uma importante relação não somente com as suas propriedades de massa, mas também com a qualidade da sua camada superficial, uma vez que apresentou forte correlação com as características de superfície avaliadas, como a dureza superficial, a microdureza e a porosimetria ao mercúrio. Além disso, salienta-se que o ensaio de dureza superficial por esclerometria poderia ser adotado como parâmetro para determinação direta da resistência ao desgaste e sugere-se que a exsudação dos pisos de concreto venha a ser o fator principal no controle da qualidade da camada superficial da placa de concreto. / Surface abrasion wear is a pathological manifestation triggered by friction between dried particles and the surface of the material, provoking a progressive loss of the outermost layers. The comprehension of this mechanism of deterioration and also the parameters that influence its occurrence are valid concerns, since it compromises the durability and functionality of structures such as concrete floors. In addition, repair this pathological manifestation or replace the damage concrete require high expenditure. Thus, the necessity of further studies seeking for practical effective actions is justified. In this particular, the aim of this work was to study the influence of properties related to the matrix and the surface of composites on abrasion resistance. For this purpose, some factors that influence the quality of the concrete used in floors, including the cement type (CP IV; CP V-ARI), the water / binder ratio (0.40, 0.60), the replacement content of silica fume (0%, 10%) and the conditions of cure (submerged; heat box) were evaluated. The assays employed in order to study the influence of mass properties on the wear mechanism were the compressive strength, flexural tensile strength and bleeding. As regards to the influence of surface properties on the magnitude of this mechanism, it was verified by testing the surface hardness, abrasion resistance, porosimetry by mercury intrusion, microhardness by indentation, analysis in stereoscopic microscope and three-dimensional laser scanning. The obtained data demonstrated a statistically significant influence of cement type on all assessed properties, with the high early strength cement presenting a better performance as compared to pozzolan cement, considering a similar age of analysis (63 days). Furthermore, there was a statistically significant influence of water / binder ratio on concrete behavior, where the water / binder ratio of 0.6 increased the wear rates of the samples in comparison to the reference (water / binder 0.4), as expected. Regarding to the conditions of cure, the submerged composites showed better results against surface wear as compared to those kept in the heat box. Finally, it was observed that the replacement content of silica fume of 10% on the cement mass provided statistically significant increases in abrasion resistance of samples with lower water / binder ratio. In addition, the presence of silica minimized the effects of curing in a heat box on the surface layer of concrete samples that were submitted to wear. In conclusion, the abrasion resistance of concretes demonstrated an important relationship not only with the mass properties of these structures but also with the quality of their surface layer, since a strong correlation with the evaluated surface features was observed, including surface hardness, microhardness and porosimetry by mercury intrusion. Moreover, it is emphasized that the surface hardness assay by rebound hammer may be used as a parameter for direct determination of wear resistance and it is suggested that bleeding of concrete floors might be the main factor for controlling the surface layer quality of the concrete slab.
|
6 |
Avaliação da resistência à abrasão, microdureza superficial e estabilidade de cor de dentes artificiais de resina acrílica / Evaluation of the abrasion resistance, superficial microhardness and color stability of acrylic resin artificial teeth.Mello, Pâmela Carbone 20 December 2007 (has links)
O objetivo deste trabalho foi avaliar in vitro a resistência a abrasão, a microdureza superficial e a estabilidade de cor de dentes artificiais de resina acrílica. Sete grupos (1- Biolux, 2- Trilux, 3- Blue Dent, 4- Biocler, 5- Orthosit-Vivodent, 6- Postaris-Antaris, 7- Gnathostar-Ivostar), compostos de 12 pre-molares superiores de cada fabricante, sendo 6 contra antagonistas metálicos (Ni-Cr) e 6 contra antagonistas de resina indireta (Solidex), foram delineados em um perfilômetro, antes e após serem submetidos ao ensaio de abrasão. A diferença linear entre a primeira e a segunda leitura foi medida com um paquímetro digital (precisao 0,01mm). Após a análise estatística (análise de variância, teste de Tukey-Kramer, nível de significancia em p<0,05), observou-se que houve diferenças estatísticas significantes entre os grupos e que a marca Postaris apresentou os menores valores de desgaste contra ambos os antagonistas (R=2,33±0,91µm e M=1,78±0,42µm). Para a análise da microdureza superficial Vickers, foram utilizados 6 incisivos laterais superiores de cada marca e 3 leituras (terços incisal, médio e cervical) foram feitas com o auxílio de um microdurômetro. As médias de microdureza superficial Vickers foram submetidas a análise estatística (nível de significancia p<0,05) e com os resultados obtidos concluiu-se que o grupo Biolux (22,1±0,91VHN) seguido do Antaris (21,9±1,58VHN), Ivostar (21,1±0,98VHN) e Biocler (21,0±1,80VHN) apresentaram maiores valores de dureza diferenciando-se do Vivodent (19,1±0,99VHN) e Blue Dent (18,9±1,54VHN), menos duros. Para o ensaio de estabilidade de cor foram utilizados 6 incisivos centrais superiores direitos de cada marca comercial (n=42), submetidos ao processo de envelhecimento artificial acelerado. O aparelho de leitura de cor utilizado foi um Espectrocolorímetro Portátil Modelo Color Guide 45/0 (BYK-Gardner, Alemanha). Cada dente teve sua cor lida antes e imediatamente após o ensaio de envelhecimento artificial. Os valores de ΔE foram submetidos a análise estatística com auxílio do programa JMP 5.1 (SAS Institute, EUA) e mostraram que houve diferenças estatisticamente significantes entres os grupos e que apenas a marca Blue Dent (4,37±0,32) apresentou valores de ΔE>3,3 considerado, segunda a literatura, clinicamente inaceitável. Para os grupos que tiveram alterações clinicamente aceitáveis, o grupo Antaris/Postaris teve a maior variação de cor (ΔE=2,73±0,96) e o grupo Biolux apresentou a menor variação de cor (1,39±0,27). Dentro das limitações da metodologia empregada, concluiu-se que o antagonista utilizado (metal ou resina) influencia a escolha do dente artificial, e que os dentes artificiais testados tem comportamentos diferentes quanto a resistência a abrasão, microdureza superficial e estabilidade de cor. / The objective of this work was to evaluate in vitro the abrasion resistance, the superficial microhardness and the color stability of acrylic resin artificial teeth. Seven groups (1-Biolux, 2 - Trilux, 3 - Blue Dent, 4 - Biocler, 5 - Orthosit-Vivodent, 6 - Postaris-Antaris, 7 - Gnathostar-Ivostar), composed of 12 upper premolar for each manufacturer\'s, being 6 against metallic antagonists (Ni-Cr) and 6 against indirect resin (Solidex) antagonists, were delineated in a perfilometer, before and after the abrasion test. The linear difference between the first and the second readings was measured with a digital calliper (0,01mm precision). After the statistical analysis (variance analysis, Tukey-Kramer\'s test, p<0.05), it was observed that there were significant differences among the groups and that the trademark Postaris presented the smallest wear values against both antagonists (R=2,33±0,91µm and M=1,78±0,42µm). For Vickers superficial microhardness, 6 lateral upper incisors of each mark and 3 readings were used (incisal, medium, and cervical thirds) done with the microdurometer. The averages of Vickers superficial microhardness were submitted to the statistical analysis (p<0.05) and the obtained results show that the group Biolux (22,1±0,91VHN) followed by Antaris (21,9±1,58VHN), Ivostar (21,1±0,98VHN) and Biocler (21,0±1,80VHN) presented higher values, differing from Vivodent (19,1±0,99VHN) and Blue Dent (18,9±1,54VHN), less harders. For the color stability test 6 upper right central incisors of each commercial mark were used (n=42), submitted to the accelerated artificial aging process. The apparel for color reading was a Portable Spectruncolorimeter Model Color Guide 45/0 (BYK-Gardner, Germany). Each tooth had his color read before and immediately after the artificial aging. The ΔE values were submitted to the statistical analysis with JMP 5.1 (HEALTHY Institute, USA) software and show that significant differences were found among the groups and that only Blue Dent (4,37±0,32) presented clinically unacceptable values of ΔE (ΔE>3.3). For the groups that had clinically acceptable color alterations, the Antaris/Postaris group had the largest color variation (ΔE=2.73±0.96) and the Biolux group presented to smallest color variation (ΔE=1.39±0.27). Within the limitations of the methodology, was concluded that the antagonist (metal or resin) influence the choice of the artificial tooth, and that the tested artificial teeth have different behaviors for the abrasion resistance, superficial microhardness and color stability.
|
7 |
Avaliação comparativa de resinas compostas fluidas em relação a resistência à abrasão (escovação simulada). / Abrasion resistance of flowable resin composites by comparative analysis of simulated toothbrushing.Garcia, Fernanda Cristina Pimentel 02 March 2001 (has links)
O presente estudo procurou analisar, através de um teste de abrasão in vitro por escovação simulada, a perda de massa e a alteração da rugosidade superficial em resinas compostas "fluidas" e resinas compostas controles. As marcas comerciais utilizadas foram: Aeliteflo-Bisco (A), Natural Flow-DFL (N), Wave-SDI (W), Flow-It Lf-Jeneric/Pentron (FLf) e Flow-It-Jeneric/Pentron (F). Uma resina composta de partículas híbridas Z100-3M (Z) e uma de micropartículas Silux Plus-3M (S) foram utilizadas como controle. Foram confeccionados 84 corpos-de-prova, de 5mm de diâmetro e 3mm de espessura, sendo 12 para cada marca comercial utilizada. Para o acabamento e o polimento dos corpos-de-prova foram utilizados discos Sof-Lex (3M) nas granulações fina (cor azul média) e superfina (cor azul claro), por tempo médio de 15/20 segundos, para cada granulação, em baixa velocidade. Para os ensaios de abrasão, foi utilizada uma máquina apropriada associada à escova Colgate Classic Infantil (Colgate-Palmolive) de cerdas macias e solução do creme dental, Colgate Proteção Anticáries com MFP (Colgate-Palmolive), diluído em água deionizada na proporção de 1:2. No teste in vitro, foram realizados aproximadamente100.000 ciclos. A determinação do desgaste dos materiais foi verificada pela quantidade de massa perdida após os ensaios, com a utilização de uma balança analítica Sartorius. A rugosidade foi determinada quantitativamente na superfície dos corpos-de-prova, com o auxílio de um rugosímetro Hommel Tester T 1000, comparando a diferença obtida após os testes de escovação e, qualitativamente, por microscopia eletrônica de varredura. Os resultados foram analisados pela variância a um critério ANOVA e pelo Teste de Tukey com p<0,05. Pelo coeficiente de Pearson não foi verificada correlação (r=-0,0296) entre porcentagem de perda de massa e rugosidade de superfície. Os materiais não apresentaram diferenças estatisticamente significantes quanto à alteração de massa, somente quanto à rugosidade superficial. A resina A apresentou a maior alteração de massa, (3,77%), seguida da resina de micropartículas S (3,04%). Em contrapartida, a resina híbrida convencional Z apresentou a menor alteração de massa (1,29%), ficando o restante das resinas "fluidas" com alteração intermediária a estas três resinas. A maior alteração de rugosidade foi verificada para a resina W (1,1720mm), com diferenças estatisticamente significantes em relação às outras resinas testadas: S (0,2749mm), Z (0,2495mm), FLf (0,1597mm), F (0,1217mm), N (0,0620mm) e A (0,0505mm). / This research aimed to assess the wear of flowable resin composites through an in vitro simulated toothbrushing abrasion test. The weight loss and surface roughness analysis were performed using five commercial brands: Aeliteflo, Flow-It, Flow-It Lf, Natural Flow and Wave. Hybrid Z-100 and Microfilled Silux Plus composites have been included as controls. Twelve samples (discs) of each material were prepared with 5mm thickness and 3mm in diameter. The test was performed up to 100.000 cicles with an appropriate machine containing soft bristles tips, dentifrice solution and deionized water in order to simulate toothbrushing. The weight loss was determined by the differences between the initial and final weights ( before and after toothbrushing) using a Sartorius analytical scale. After 5 readings, in a T 1000 Hommel testing machine, the evaluation of surface roughness was obtained by the differences between initial and final means. The analyzed ( ANOVA and Tukey, p< 0,05) results showed that Silux Plus, Flow-it, Wave, Flow-It Lf and Natural Flow had an intermediate weight loss (3,04; 2,70; 2,19; 2,12 and 2,04% respectively). Z-100 exhibited the lowest (1,29%) weight loss, whereas Aeliteflo, the highest (3,77%). Wave showed the highest surface roughness variation (1,1720mm), statistically different from the other groups, which exhibited the following differences: Silux Plus (0,2749mm), Z-100 (0,2495mm), Flow-it Lf (0,1597mm), Flow-It (0,1217mm), Natural Flow (0,0620mm) and Aeliteflo (0,0506mm). Aeliteflo presented the highest weight loss and the lowest surface roughness difference; on the other hand, Wave showed the highest surface roughness difference and an intermediate weight loss when compared with the other tested resins.
|
8 |
Effect Of Resin And Fiber On The Abrasion, Impact And Pressure Resistance Of Cylindrical Composite StructuresKaya, Derya 01 June 2011 (has links) (PDF)
The aim of this study was to investigate the effects of resin and fiber on the abrasion, impact and internal pressure resistances of fiber reinforced plastic composite pipes produced by continuous filament winding method. For this study, pipe samples were produced with different combinations of resin type, fiber type, fiber amount and fiber length. All the samples were tested in accordance with the related ISO (International Organization for Standardization), DIN (German Standardization Institution) and BSI (British Standards Institution) standards. Three types of resins were used as ortophthalic, isophthalic and vinylester / two types of fibers were used as E-glass and ECR-glass and one type of GLASSFLAKES was used as C-glass. It was observed that the type of resin did not have any significant effect on burst pressure. However, the vinylester resin had a considerable positive effect on the abrasion and impact resistances. Moreover, it was observed that the type of fiber did not have any significant effect on impact and internal pressure resistances, but the use of C-glass GLASSFLAKES resulted in a positive effect on the abrasion resistance. Additionally, it was found that the increase in the amount of glass fiber resulted in increase of burst pressure, impact and abrasion resistances. Finally, it was observed that the length of glass fiber did not have any significant effect on abrasion resistance, but the decrease in fiber length resulted in a higher internal pressure and impact resistances.
|
9 |
Estudo da influência das propriedades relacionadas à superfície e à matriz na resistência à abrasão de concretos para pisos / Study on the influence of properties related to the surface and matrix in the abrasion resistance of concrete floorsSilva, Cristina Vitorino da January 2015 (has links)
O desgaste superficial por abrasão é uma manifestação patológica que decorre do atrito entre partículas secas e a superfície do material, causando uma perda progressiva das camadas mais externas da estrutura. Entender esse mecanismo de deterioração e ainda os parâmetros que influenciam a sua ocorrência são preocupações válidas, visto que ele compromete a durabilidade e a funcionalidade de estruturas, tais como pisos de concreto. Além disso, a correção desta manifestação patológica exige gastos elevados com reparo ou substituição do concreto e, dessa maneira, a necessidade de maiores estudos buscando ações mais efetivas na prática é justificada. Neste particular, estudou-se a influência das propriedades relacionadas à matriz e à superfície na resistência à abrasão dos compósitos. Para tanto, alguns fatores que influenciam na qualidade dos concretos empregados em pisos, como o tipo de cimento (CP IV; CP V-ARI), a relação água/aglomerante (0,40; 0,60), o teor de substituição de sílica ativa (0%; 10%) e o tipo de cura (submersa; caixa aquecida) foram avaliados. Os ensaios adotados para estudar a influência das propriedades de massa no mecanismo de degaste foram os de resistência à compressão uniaxial, resistência à tração na flexão e exsudação. Já os ensaios para verificar a influência das propriedades de superfície na magnitude desse mecanismo foram os de dureza superficial, resistência à abrasão, porosimetria por intrusão de mercúrio, microdureza por indentação, análises em microscópio estereoscópico e a digitalização tridimensional à laser. Os resultados encontrados mostraram uma influência estatística significativa do tipo de cimento sobre todas as propriedades avaliadas, sendo que o cimento de alta resistência inicial apresentou melhor desempenho em comparação ao cimento pozolânico, considerando uma mesma idade de análise (63 dias). Além disso, verificou-se uma influência estatística significativa da relação a/agl no comportamento dos concretos, onde a relação a/agl 0,6 aumentou os índices de desgaste das amostras em relação as de referência (a/agl 0,4), conforme esperado. Quanto ao tipo de cura, os compósitos curados de forma submersa apresentaram os melhores resultados frente ao desgaste superficial comparando-se àqueles mantidos na cura em caixa aquecida. Finalmente, analisando o teor de substituição de sílica ativa, observou-se que a substituição de 10 % sobre a massa de cimento proporcionou acréscimos estatisticamente significativos na resistência à abrasão das amostras com menor relação a/agl; somando-se a isto, a presença da sílica minimizou o efeito da cura em caixa aquecida na camada superficial das amostras de concreto submetidas ao desgaste. Concluindo, a resistência à abrasão dos concretos mostrou ter uma importante relação não somente com as suas propriedades de massa, mas também com a qualidade da sua camada superficial, uma vez que apresentou forte correlação com as características de superfície avaliadas, como a dureza superficial, a microdureza e a porosimetria ao mercúrio. Além disso, salienta-se que o ensaio de dureza superficial por esclerometria poderia ser adotado como parâmetro para determinação direta da resistência ao desgaste e sugere-se que a exsudação dos pisos de concreto venha a ser o fator principal no controle da qualidade da camada superficial da placa de concreto. / Surface abrasion wear is a pathological manifestation triggered by friction between dried particles and the surface of the material, provoking a progressive loss of the outermost layers. The comprehension of this mechanism of deterioration and also the parameters that influence its occurrence are valid concerns, since it compromises the durability and functionality of structures such as concrete floors. In addition, repair this pathological manifestation or replace the damage concrete require high expenditure. Thus, the necessity of further studies seeking for practical effective actions is justified. In this particular, the aim of this work was to study the influence of properties related to the matrix and the surface of composites on abrasion resistance. For this purpose, some factors that influence the quality of the concrete used in floors, including the cement type (CP IV; CP V-ARI), the water / binder ratio (0.40, 0.60), the replacement content of silica fume (0%, 10%) and the conditions of cure (submerged; heat box) were evaluated. The assays employed in order to study the influence of mass properties on the wear mechanism were the compressive strength, flexural tensile strength and bleeding. As regards to the influence of surface properties on the magnitude of this mechanism, it was verified by testing the surface hardness, abrasion resistance, porosimetry by mercury intrusion, microhardness by indentation, analysis in stereoscopic microscope and three-dimensional laser scanning. The obtained data demonstrated a statistically significant influence of cement type on all assessed properties, with the high early strength cement presenting a better performance as compared to pozzolan cement, considering a similar age of analysis (63 days). Furthermore, there was a statistically significant influence of water / binder ratio on concrete behavior, where the water / binder ratio of 0.6 increased the wear rates of the samples in comparison to the reference (water / binder 0.4), as expected. Regarding to the conditions of cure, the submerged composites showed better results against surface wear as compared to those kept in the heat box. Finally, it was observed that the replacement content of silica fume of 10% on the cement mass provided statistically significant increases in abrasion resistance of samples with lower water / binder ratio. In addition, the presence of silica minimized the effects of curing in a heat box on the surface layer of concrete samples that were submitted to wear. In conclusion, the abrasion resistance of concretes demonstrated an important relationship not only with the mass properties of these structures but also with the quality of their surface layer, since a strong correlation with the evaluated surface features was observed, including surface hardness, microhardness and porosimetry by mercury intrusion. Moreover, it is emphasized that the surface hardness assay by rebound hammer may be used as a parameter for direct determination of wear resistance and it is suggested that bleeding of concrete floors might be the main factor for controlling the surface layer quality of the concrete slab.
|
10 |
Estudo da influência das propriedades relacionadas à superfície e à matriz na resistência à abrasão de concretos para pisos / Study on the influence of properties related to the surface and matrix in the abrasion resistance of concrete floorsSilva, Cristina Vitorino da January 2015 (has links)
O desgaste superficial por abrasão é uma manifestação patológica que decorre do atrito entre partículas secas e a superfície do material, causando uma perda progressiva das camadas mais externas da estrutura. Entender esse mecanismo de deterioração e ainda os parâmetros que influenciam a sua ocorrência são preocupações válidas, visto que ele compromete a durabilidade e a funcionalidade de estruturas, tais como pisos de concreto. Além disso, a correção desta manifestação patológica exige gastos elevados com reparo ou substituição do concreto e, dessa maneira, a necessidade de maiores estudos buscando ações mais efetivas na prática é justificada. Neste particular, estudou-se a influência das propriedades relacionadas à matriz e à superfície na resistência à abrasão dos compósitos. Para tanto, alguns fatores que influenciam na qualidade dos concretos empregados em pisos, como o tipo de cimento (CP IV; CP V-ARI), a relação água/aglomerante (0,40; 0,60), o teor de substituição de sílica ativa (0%; 10%) e o tipo de cura (submersa; caixa aquecida) foram avaliados. Os ensaios adotados para estudar a influência das propriedades de massa no mecanismo de degaste foram os de resistência à compressão uniaxial, resistência à tração na flexão e exsudação. Já os ensaios para verificar a influência das propriedades de superfície na magnitude desse mecanismo foram os de dureza superficial, resistência à abrasão, porosimetria por intrusão de mercúrio, microdureza por indentação, análises em microscópio estereoscópico e a digitalização tridimensional à laser. Os resultados encontrados mostraram uma influência estatística significativa do tipo de cimento sobre todas as propriedades avaliadas, sendo que o cimento de alta resistência inicial apresentou melhor desempenho em comparação ao cimento pozolânico, considerando uma mesma idade de análise (63 dias). Além disso, verificou-se uma influência estatística significativa da relação a/agl no comportamento dos concretos, onde a relação a/agl 0,6 aumentou os índices de desgaste das amostras em relação as de referência (a/agl 0,4), conforme esperado. Quanto ao tipo de cura, os compósitos curados de forma submersa apresentaram os melhores resultados frente ao desgaste superficial comparando-se àqueles mantidos na cura em caixa aquecida. Finalmente, analisando o teor de substituição de sílica ativa, observou-se que a substituição de 10 % sobre a massa de cimento proporcionou acréscimos estatisticamente significativos na resistência à abrasão das amostras com menor relação a/agl; somando-se a isto, a presença da sílica minimizou o efeito da cura em caixa aquecida na camada superficial das amostras de concreto submetidas ao desgaste. Concluindo, a resistência à abrasão dos concretos mostrou ter uma importante relação não somente com as suas propriedades de massa, mas também com a qualidade da sua camada superficial, uma vez que apresentou forte correlação com as características de superfície avaliadas, como a dureza superficial, a microdureza e a porosimetria ao mercúrio. Além disso, salienta-se que o ensaio de dureza superficial por esclerometria poderia ser adotado como parâmetro para determinação direta da resistência ao desgaste e sugere-se que a exsudação dos pisos de concreto venha a ser o fator principal no controle da qualidade da camada superficial da placa de concreto. / Surface abrasion wear is a pathological manifestation triggered by friction between dried particles and the surface of the material, provoking a progressive loss of the outermost layers. The comprehension of this mechanism of deterioration and also the parameters that influence its occurrence are valid concerns, since it compromises the durability and functionality of structures such as concrete floors. In addition, repair this pathological manifestation or replace the damage concrete require high expenditure. Thus, the necessity of further studies seeking for practical effective actions is justified. In this particular, the aim of this work was to study the influence of properties related to the matrix and the surface of composites on abrasion resistance. For this purpose, some factors that influence the quality of the concrete used in floors, including the cement type (CP IV; CP V-ARI), the water / binder ratio (0.40, 0.60), the replacement content of silica fume (0%, 10%) and the conditions of cure (submerged; heat box) were evaluated. The assays employed in order to study the influence of mass properties on the wear mechanism were the compressive strength, flexural tensile strength and bleeding. As regards to the influence of surface properties on the magnitude of this mechanism, it was verified by testing the surface hardness, abrasion resistance, porosimetry by mercury intrusion, microhardness by indentation, analysis in stereoscopic microscope and three-dimensional laser scanning. The obtained data demonstrated a statistically significant influence of cement type on all assessed properties, with the high early strength cement presenting a better performance as compared to pozzolan cement, considering a similar age of analysis (63 days). Furthermore, there was a statistically significant influence of water / binder ratio on concrete behavior, where the water / binder ratio of 0.6 increased the wear rates of the samples in comparison to the reference (water / binder 0.4), as expected. Regarding to the conditions of cure, the submerged composites showed better results against surface wear as compared to those kept in the heat box. Finally, it was observed that the replacement content of silica fume of 10% on the cement mass provided statistically significant increases in abrasion resistance of samples with lower water / binder ratio. In addition, the presence of silica minimized the effects of curing in a heat box on the surface layer of concrete samples that were submitted to wear. In conclusion, the abrasion resistance of concretes demonstrated an important relationship not only with the mass properties of these structures but also with the quality of their surface layer, since a strong correlation with the evaluated surface features was observed, including surface hardness, microhardness and porosimetry by mercury intrusion. Moreover, it is emphasized that the surface hardness assay by rebound hammer may be used as a parameter for direct determination of wear resistance and it is suggested that bleeding of concrete floors might be the main factor for controlling the surface layer quality of the concrete slab.
|
Page generated in 0.0974 seconds