• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 39
  • 1
  • 1
  • Tagged with
  • 41
  • 41
  • 28
  • 24
  • 12
  • 11
  • 10
  • 8
  • 8
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Aplicação de uma fração do resíduo do shredder na fabricação de blocos cerâmicos estruturais

Figueiredo, Juliana Dias de Castro January 2016 (has links)
O objetivo deste trabalho é avaliar a incorporação de uma fração cuja fração granulométrica é menor que 2mm do resíduo do Shredder proveniente de uma indústria siderúrgica ao processo de fabricação de blocos cerâmicos estruturais de uma fábrica de cerâmica vermelha. As variáveis analisadas foram: dimensões, propriedades de resistência à compressão, absorção de água e quanto às questões ambientais pela análise de lixiviação e solubilização segundo a NBR 10.004 (ABNT, 2004). Foi realizado processamento do resíduo do Shredder em uma fração menor que 2mm e realizada a incorporação de uma dosagem de 10% e 20% deste material no processo industrial de uma cerâmica de produção de blocos estruturais. Foram avaliadas as propriedades de qualidade e quanto às questões ambientais. Analisando os resultados constatou-se que tanto o bloco cerâmico padrão quanto aos protótipos contendo 10% e 20% de resíduo atendem os limites normativos para resistência à compressão e para absorção de água. Na análise dimensional, somente o protótipo contendo 10% de resíduo atende todos os parâmetros quanto os requisitos normativos.Pelas análises de lixiviado e solubilizado, concluiu-se que tanto o bloco cerâmico estrutural padrão quanto ao protótipo contendo 20% de resíduo são classificados como Classe II A- não inerte. É possível afirmar que a fração menor que 2mm do resíduo do Shredder pode ser utilizada junto à massa cerâmica como matéria-prima para fabricação de blocos cerâmicos estruturais. / The goal of this work is to evaluate the incorporation of a fraction smaller than 2 mm of the Shredder Residue from a steel industry into a manufacturing process of structural bricks in a red ceramic factory. Evaluate the quality of results as the compressive strength properties, water absorption and environmental issues as leaching and solubilization analysis according to NBR 10.004 (ABNT, 2004). The Shredder Residue in a fraction smaller than 2mm was incorporated in dosages of 10% and 20% with the clay in the industrial process of a ceramic which produces structural blocks. The quality properties and the environmental issues were analyzed and the results was that both brick pattern block and the prototypes containing 10% and 20% residue meet regulatory limits for compressive strength and water absorption. The analysis of leached and solubilized concluded that both the brick pattern and the prototype containing 20% of waste are classified as Class II A – non inert residue. It is possible to say that the fraction smaller than 2mm of Automotive Shredder Residue can be used with the clay as raw material for the manufacture of structural ceramic blocks.
22

Influência da microfissuração causada nas primeiras idades na durabilidade de concretos ao longo do tempo (Self-Healing)

Venquiaruto, Simone Dornelles January 2017 (has links)
A racionalização e industrialização da construção promoveram profundas modificações no processo construtivo e nas técnicas gerenciais no Brasil. Muitas empresas construtoras, para garantir competitividade no mercado, buscaram soluções capazes de aumentar a velocidade de suas obras, tais como a redução do período de escoramento. A retirada antecipada do escoramento submete a estrutura a carregamento precoce, podendo desencadear a microfissuração do concreto. Como consequência, as deformações instantâneas e lentas tendem a aumentar e, consequentemente, manifestações patológicas podem ocorrer com maior intensidade. Objetivando simular o dano causado pela retirada antecipada do escoramento em idades iniciais, este trabalho investigou a influência do carregamento precoce por compressão axial na durabilidade de concretos distintos. O programa experimental foi executado em duas etapas. A primeira, investigou a influência da microfissuração causada por carregamento precoce na durabilidade de concretos produzidos com três tipos de cimento (CPV-ARI, CPIV RS e CPII Z) e três relações água/cimento (0,35, 0,50 e 0,70). Os carregamentos dos corpos de prova foram realizados em laboratório nas idades de 1, 3 e 7 dias. Para cada idade de carregamento foram rompidas, até o limite, duas amostras de referência e, a partir do valor médio de ruptura obtido, determinava-se os percentuais de carga (25%, 50% e 75%) que seriam aplicados nos concretos. Após o período de cura de 28 dias, as amostras foram ensaiadas à Penetração de Íons Cloreto e à Absorção Capilar de Água. A segunda etapa do programa experimental investigou a influência do prolongamento da cura na recuperação do dano causado pelo carregamento dos concretos nas primeiras idades. Foram produzidos concretos com dois tipos de cimento (CPV-ARI e CPIV) e uma relação água/cimento (0,50). Parte dos concretos receberam pré-carregamento de 75% da carga de ruptura na idade de 3 dias e parte permaneceu intacta, para servir como referência. Os ensaios mecânicos e de durabilidade (penetração de íons cloreto) foram executados ao longo do tempo (3, 7, 28 e 91 dias). Os resultados da Etapa 1 mostraram que, para todas as misturas investigadas, houve elevação da penetração de cloretos e da absorção de água com o aumento da intensidade do carregamento e da relação água/cimento dos concretos. Também foi observado a existência de um processo de microfissuração causado pela ação dos pré-carregamentos dos concretos com pouca idade. Os melhores desempenhos foram obtidos para as misturas com cimentos pozolânicos e não submetidas ao carregamento. Os resultados observados na Etapa 2 mostraram que o aumento do período de cura dos concretos refletiu positivamente nos resultados dos ensaios mecânicos e de durabilidade. Nessa etapa, também foram realizados ensaios microestruturais complementares que permitiram observar que a continuidade da cura promoveu uma recuperação parcial das microfissuras (self-healing) nos concretos. No entanto, nem todas foram fechadas. Constatou-se que as magnitudes das microfissuras remanescentes eram tal que poderiam se tornar um caminho preferencial para a entrada de íons cloreto nos concretos. Conclui-se que todos os concretos analisados apresentaram a mesma tendência de comportamento, de redução da entrada de íons cloreto com o aumento do período de cura. No entanto, o diferencial dos resultados foi notado na intensidade dos valores observados, significantemente reduzidos para os cimentos pozolânicos. / The rationalization and industrialization of the construction promoted deep changes in the constructive process and on the management techniques in Brazil. Most of the construction companies look for solutions that allow it to increase the speed of the constructions to ensure competitiveness on the market, such as the reduction on the time of structure execution, as well as the period of scores and anticipating the beginning of the masonry building. The early removal of the scores put the structure in an early loading without giving enough time to part of the cement hydration reactions happen, starting the concrete micro cracking process. Consequently, the instantaneous and slow deformations tend to increase and hence, pathologies may occur with greater intensity. This work researches the influence of early loading, by axial compression, in the durability of different types of concrete. The experimental program was implemented in two stages. The first stage investigated the influence of the micro cracking caused by pre loading on the durability of concretes produced with three different types of cement classified based on the Brazilian standards (CPV-ARI, CPIV RS and CPII Z) and three water/cement ratios (0.35, 0.50 and 0.70). The samples loading were realized in laboratory at the ages of 1, 3 and 7 days. Two reference samples were loaded until the limit, for each age of loading, and according to this average value of loading the percentage of loading to be applied on the samples in order to perform the durability tests were calculated (25%, 50% and 75%). The samples were placed in humid chamber for 28 days. After the cure period the samples were tested to Chloride ions penetration and water capillary absorption. The second stage of the experimental program investigated the influence of prolonged healing in the recovery of the damage caused by the concrete loading at early ages (microcracks). Concretes were produced with two types of cement (CPV-ARI and CPIV) and a water/cement ratio of 0,50. Part of the concrete received preload 75% of the tensile strength at age 3 days and some remained intact to serve as reference. The mechanical and durability tests were performed over time (3, 7, 28 and 91 days). The results of the first stage of the experimental program demonstrated that, for all the cements the increasing of the chloride penetration and water absorption is directly related with the increasing of the pre loading applied, to the increasing of the water/cement ratio on the mixture and the reduction of the age of the pre loading.The results obtained in Stage-1 confirmed the existence of a microcracking process caused by the action of the preload concrete at a young age. The best performances were observed for mixtures with pozzolan cement and not subjected to loading. The continued healing promoted a partial recovery of microcracks, verified by scanning electron microscopy images (SEM). However, not all were closed. It was found that the magnitude of the remaining microcracks were such that it could become a preferred path for the entry of chloride ions in concrete. All examined concrete showed the same trend behavior, reduction of the entrance of chloride ions with increasing curing period. However, the spread of results was noticed in the intensity of the observed values, significantly reduced for pozzolanic cements.
23

Transiente de corrente elétrica em amostras de PVDF devido a água de volume / Transient of electric current of PVDF films due to water molecules

Neri Alves 24 March 1987 (has links)
Uma condutividade evanescente, dependente do tempo, tem sido detectada nos filmes de PVDF da BembergFolien. Após muitos ciclos de polarização e despolarização, a corrente de absorção torna-se fortemente reduzida, para o mesmo nível das correntes de despolarização. Esta condutividade é facilmente observada, aparecendo na corrente de polarização pela aplicação de altos campos. É observada recuperação em amostras deixadas em atmosfera úmida. Nós interpretamos estas observações como sendo uma limpeza, pelo campo elétrico, dos íons gerados por uma acentuação da dissociação de moléculas de água absorvida no volume, pela ação deste campo. / A time dependent evanescent conductivity has been detected in BembergFoliem PVDF films. After many polarization-depolarization cycles, the absorption current became strongly reduced, to the same level as the depolarization one. It is easily seen at higher fields by a bump appearing in the polarization current Recovering is observed in samples left in humid atmosphere. We have interpreted these observations as an electric field ion cleaning of an electric field enhanced dissociation of bulk absorbed water molecules.
24

Avaliação da distância máxima de absorção de nutrientes em formações florestais tropicais usando 15N como marcador /

Pinheiro, Rafael Costa January 2019 (has links)
Orientador: Jean-Paul Laclau / Resumo: As mudanças climáticas têm causado alterações na temperatura e também nos regimes de precipitação do planeta, aumentando a probabilidade de ocorrência de secas mais severas, o que, no cenário florestal, pode resultar na mortalidade de florestas ao redor do mundo. Assim, é necessário um conhecimento mais detalhado sobre a dinâmica de absorção de água e nitratos pelas raízes das árvores, que explique o comportamento das árvores sob extrema seca. O objetivo do estudo foi avaliar a distância máxima do tronco e a profundidade máxima de absorção de nutrientes e água pelas raízes das árvores em florestas crescendo sobre Neossolos Quartzarênicos muito profundos, utilizando o 15N como marcador. As consequências do status social das árvores, comparando árvores dominantes e dominadas do mesmo genótipo numa floresta monoclonal foram estudadas em plantios de um clone híbrido de Eucalyptus urophylla x Eucalyptus grandis durante a estação seca. Os efeitos da sazonalidade (comparando as estações seca e chuvosa) foram estudados em três espécies do Cerrado: i) Xylopia aromatica (Lam.) Mart.; ii) Coussarea hydrangeifolia (Benth.) Müll.Arg.; and iii) Miconia albicans (Sw.) Steud. Além disso, foi avaliada a existência de uma complementaridade de nicho no solo entre essas espécies do Cerrado, com uma absorção do marcador em camadas diferentes. O marcador NO3--15N foi aplicado em talhões de eucalipto com 7 meses, 1,2 anos, 2,2 anos e 6,4 anos de idade, a várias profundidades do solo em 60 pontos, s... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
25

Avaliação da liberação de monômero residual, absorção de água e porosidade superficial em resinas acrílicas para prótese ocular / Evaluation of residual monomer, water sorption and porosity by acrylic resins used to eye prostheses

Oliveira, Rodrigo Elias de 07 March 2008 (has links)
A necessidade do aprimoramento das técnicas de confecção de próteses oculares que permitam satisfazer, com rapidez e excelência, a demanda de atendimento de pacientes portadores de perdas do bulbo ocular, levou ao desenvolvimento deste estudo comparativo no qual se avalia a porosidade superficial, absorção de água e liberação de monômero residual de resinas acrílicas. Foram estabelecidos quatro grupos de estudo, sendo cada grupo composto por 15 corpos de prova: Grupo 1 - resina acrílica termo polimerizável convencional / ciclo térmico convencional; Grupo 2 - resina acrílica termo polimerizável em microondas / ciclo microondas; Grupo 3 - resina acrílica termo polimerizável convencional / ciclo microondas; Grupo 4 - resina acrílica auto polimerizável com cadeia cruzada / auto polimerização. A avaliação da quantidade de monômero residual liberado foi realizada por meio de espectrofotometria, durante o período de 11 dias. A determinação da absorção de água baseou-se na diferença do peso apresentado pelos corpos de prova nas condições experimentais seco e após submersão em água deionizada por um período de 7 dias. A determinação da porosidade superficial foi calculada sob a forma de porcentagem por área de superfície analisada, empregando-se lupa estereoscópica para captação da imagem a ser processada pelo software ImageLab 2000®. Submetendo-se os dados à análise estatística ANOVA/TUKEY (p<=0,05) observou-se que a liberação de monômero residual foi significantemente maior no primeiro dia para o Grupo 1, semelhante durante todo o período para o Grupo 2, menor a partir do dia 8 para o Grupo 3 e decrescente até o dia 8 para o Grupo 4. A liberação de monômero residual foi semelhante para os Grupos 1 e 3, menor para o Grupo 2 e maior para o Grupo 4. A absorção de água foi semelhante para os quatro grupos de estudo. A maior porosidade ocorreu no Grupo 2, sendo os Grupos 1 e 3 semelhantes entre si. Concluiu-se que os ciclos térmicos de polimerização em água e em microondas não interferiram na liberação de monômero residual da resina acrílica termo polimerizável convencional. A liberação de monômero residual variou em função do tipo de resina acrílica. O tipo de resina acrílica e o ciclo de polimerização a que foram submetidas não interferiram na absorção de água. Os ciclos térmicos de polimerização em água e em microondas não interferiram na porosidade apresentada pela resina acrílica termo polimerizável convencional. A porosidade superficial variou em função do tipo de resina acrílica avaliada. / This comparative evaluation of porosity, water sorption and residual monomer presented by acrylic resins was conducted, looking for excellence and rapidity in the confection of eye prostheses. Four groups, comprising of 15 specimens each, were established and submitted to polymerization cycles: Group 1 - conventional heat polymerizing acrylic resin / conventional heat-polymerization cycle; Group 2 - microwave acrylic resin / microwave cycle; Group 3 - conventional heat polymerizing acrylic resin / microwave cycle; Group 4 - cross-linked auto-polymerizing acrylic resin / auto-polymerizing process. Residual monomer liberation was determined by spectrophotometry during 11 days period. Water sorption was calculated by weighting dried specimens and weighting after 7 days of submersion in deionized water. Superficial porosity was determined by percentage of area, in images processed by the software ImageLab 2000®. Subjecting data to ANOVA/TUKEY test (p<=0,05) it was observed that residual monomer liberation was higher in the first day for Group 1, similar during all the period for Group 2, lower after day 8 for Group 3 and decreasing until day 8 for Group 4. Residual monomer liberation was similar to Groups 1 and 3, lower for Group 2 and higher for Group 4. Water sorption was similar to all groups. Group 2 displayed more superficial porosity, and Group 1 and 3 were similar regarding this test. In conclusion, conventional polymerization and microwave processes did not interfere in residual monomer liberation of conventional acrylic resin. The residual monomer liberation varied according the type of acrylic resin. Microwave cycle provided similar or smaller residual monomer liberation. The type of acrylic resin and the polymerization cycle utilized did not modify water sorption. The conventional heat polymerizing cycle and microwave cycle did not interfere in superficial porosity of conventional heat polymerizing acrylic resin. The superficial porosity varied according to the acrylic resin.
26

Avaliação da resistência à compressão e da absorção de água de concretos utilizados após o tempo máximo de mistura e transporte especificado pela NBR 7212 / Evaluation of compressive strength and water absorption of concrete used after the maximum time of mixing and transport specified by NBR 7212

Polesello, Eduardo January 2012 (has links)
A norma brasileira NBR 7212 (ABNT, 1984), para execução de concreto dosado em central, estipula o tempo máximo para que o concreto seja descarregado (aplicado) completamente em 150 minutos. O tempo para utilização do concreto está vinculado às reações de hidratação do cimento e à perda de abatimento que ocorre com o concreto fresco, um fenômeno normal definido como sendo a perda de fluidez com o passar do tempo. Essa propriedade do concreto é particularmente importante no caso de concreto dosado em centrais, pelo fato do primeiro contato da água com o cimento ser na central enquanto que o lançamento/adensamento ocorrerá alguns minutos ou horas depois, quando o caminhão betoneira chegar ao canteiro de obras. Na prática, muitas vezes, ocorrem situações onde caminhões ficam carregados com concreto por 4 ou 5 horas, em função de atrasos no transporte ou na descarga, caracterizando um tempo bem acima do limite especificado pela norma. A dúvida de utilizar ou não o concreto nessas condições existe, pois não há conhecimento consolidado quanto às suas propriedades finais quando empregado com tempo de mistura que já tenham excedido o limite máximo especificado por norma. O objetivo desta pesquisa é investigar o comportamento de concretos do ponto de vista da resistência à compressão e absorção de água, quando utilizados com tempo de mistura de até 6 horas. Os concretos foram produzidos com dois tipos de cimento, CPIV e CPII, e o abatimento foi mantido ao longo das 6 horas em mistura com a incorporação de aditivo superplastificante à base policarboxilato. Nesse estudo adotaram-se três relações a/c e a produção dos concretos foi realizada em laboratório e em condição real numa central dosadora de concreto. As propriedades estudadas, resistência à compressão e absorção de água, foram analisadas aos 28 dias para vários tempos de mistura. O estudo mostrou que o tempo para utilização do concreto pode ser estendido acima do tempo especificado pela norma, sem que haja perda de sua resistência à compressão e alterações na absorção de água ao longo do tempo. / The Brazilian standard NBR 7212 (ABNT, 1984), for execution of ready-mixed concrete, specifies the maximum time for concrete to be discharged (used) completely in 150 minutes. The usage time of the concrete is due to reactions of the cement hydration and slump loss that occurs with fresh concrete, a normal phenomenon defined as the loss of fluidity along the time. This property of concrete is particularly important in the case of ready-mixed concrete plants, because the first contact of water with the cement is in the ready-mixed concrete plants while launching / densification occurs minutes or hours later, when the mixer truck arrives at the construction site. In fact, often, there are situations where trucks are loaded with concrete by 4 or 5 hours, due to delays in transportation or unloading, characterizing some time well above the limit specified by the standard. The question is to use or not use the concrete on these conditions, because there are no studies that confirm the final properties of the concrete when used with mixing time that have already exceeded the maximum limit specified by the standard. The aim of this study is to investigate the behavior of concrete from viewpoint of compressive strength and water absorption when used with mixing time up to 6 hours. The concretes were produced with two types of cement, CPIV and CPII, and slump was kept up to the six hours in a mixture with the incorporation of superplasticizer based polycarboxylate. In this study were adopted three relations w/c and the production of concrete was done in laboratory and real conditions in a ready-mixed concrete plants. The studied properties, compressive strength and water absorption were analyzed in 28 days for several mixing times. The study showed that the time of use from the concrete can be extended over the time specified by the standard, without loss of compressive strength and changes in the water absorption over time.
27

Propriedades de agregados reciclados carbonatados para aplicação em concreto / Propeties of recycled carbonate aggregates for concrete application

Tenório, Májores de Omena 22 December 2016 (has links)
Concrete is a material obtained by mixing raw materials such as cement, aggregates and water, and its per capita utilization is only behind water. Due to its large volume of use, it presents itself as a growing generator of waste and waste in civil construction. From the need to minimize these impacts on the environment with the possibility of reuse of concrete residues, transforming them into recycled concrete aggregates (ARGC). These materials are presented with high water absorption capacity and low specific mass. An alternative to improve this feature is the use of accelerated carbonation, which acts through the pores of the mortar adhered to the natural aggregate, producing carbonate elements that reduce the water absorption capacity and increase the specific mass. The objective of this research is to analyze the properties of the carbonated ARGC for concrete application. For this, a chamber was used in which the ARGC were submitted to concentrations of carbon dioxide. From the verification of the impact of carbonation on the samples, analyzed in mineralogical, thermal, microscopic and physical characterization tests, using as determinant impact value of the process, the capacity of absorption and specific mass, it was developed the reproduction of the carbonation parameters In scale for concrete production. They were produced: a reference concrete, with aggregates without carbonation, and their properties were compared with the samples of concrete with carbonated CGA, and analyzed its properties in fresh and hardened state. The ARGC presented, in its non-carbonated form, high absorption and low density, when compared to the natural aggregate, in contrast carbonation modified this picture with the formation of expansive products based on carbonates, which decreased the water absorption capacity and increased The density of carbonated ARGC when compared to untreated ARGC. Carbonation through the chamber proved to be an efficient method in this process, reflecting the behavior of the ARGC, which showed a decrease of 16.5% in the absorption capacity, a 1.53% increase in the specific mass and the formation of carbonates between the pores Of the ARGC. The concretes presented fluid abatement, mechanical strength of 25 MPa at 28 days and a mean carbonation depth of 12 mm. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O concreto é um material obtido pela mistura de matérias-primas como cimento, agregados e água, e sua utilização per capita fica atrás somente da água. Devido ao seu grande volume de utilização, apresenta-se como crescente gerador de resíduos e de desperdícios dentro da construção civil. A partir da necessidade de se minimizar estes impactos sobre o meio ambiente com a possibilidade de reutilização dos resíduos de concreto, transformando-os em agregados reciclados graúdos de concreto (ARGC). Estes materiais apresentam-se com alta capacidade de absorção de água e baixa massa específica. Uma alternativa para melhorar esta característica é a utilização da carbonatação acelerada, que age através dos poros da argamassa aderida ao agregado natural, produzindo elementos carbonáticos que reduzem a capacidade de absorção de água e aumentam a massa específica. O objetivo desta pesquisa é analisar as propriedades dos ARGC carbonatados para aplicação em concretos. Para isto foi utilizada uma câmara na qual os ARGC foram submetidos a concentrações de dióxido de carbono. A partir da verificação do impacto da carbonatação nas amostras, analisado em ensaios de caracterização mineralógica, térmicas, microscópicas e físicas, usando como valor de impacto determinante do processo, a capacidade de absorção e massa específica, desenvolveu-se a reprodução dos parâmetros da carbonatação em escala para produção de concretos. Foram produzidos: um concreto de referência, com agregados sem carbonatação, e suas propriedades foram comparadas com as amostras de concreto com ARGC carbonatado, e analisadas suas propriedades no estado fresco e endurecido. O ARGC apresentou, em sua forma não carbonatada, alta absorção e baixa densidade, quando comparados ao agregado natural, em contraponto a carbonatação modificou este quadro com a formação de produtos expansivos a base de carbonatos, que diminuíram a capacidade de absorção de água e aumentaram a densidade do ARGC carbonatado quando comparado ao ARGC sem tratamento. A carbonatação através da câmara mostrou-se um método eficiente neste processo, refletindo no comportamento do ARGC, que apresentou diminuição de 16,5% na capacidade de absorção, 1,53% de aumento na massa específica e a formação de carbonatos entre os poros do ARGC. Os concretos apresentaram abatimento fluido, resistência mecânica de 25 MPa aos 28 dias e uma profundidade de carbonatação média de 12 mm.
28

Avaliação da resistência à compressão e da absorção de água de concretos utilizados após o tempo máximo de mistura e transporte especificado pela NBR 7212 / Evaluation of compressive strength and water absorption of concrete used after the maximum time of mixing and transport specified by NBR 7212

Polesello, Eduardo January 2012 (has links)
A norma brasileira NBR 7212 (ABNT, 1984), para execução de concreto dosado em central, estipula o tempo máximo para que o concreto seja descarregado (aplicado) completamente em 150 minutos. O tempo para utilização do concreto está vinculado às reações de hidratação do cimento e à perda de abatimento que ocorre com o concreto fresco, um fenômeno normal definido como sendo a perda de fluidez com o passar do tempo. Essa propriedade do concreto é particularmente importante no caso de concreto dosado em centrais, pelo fato do primeiro contato da água com o cimento ser na central enquanto que o lançamento/adensamento ocorrerá alguns minutos ou horas depois, quando o caminhão betoneira chegar ao canteiro de obras. Na prática, muitas vezes, ocorrem situações onde caminhões ficam carregados com concreto por 4 ou 5 horas, em função de atrasos no transporte ou na descarga, caracterizando um tempo bem acima do limite especificado pela norma. A dúvida de utilizar ou não o concreto nessas condições existe, pois não há conhecimento consolidado quanto às suas propriedades finais quando empregado com tempo de mistura que já tenham excedido o limite máximo especificado por norma. O objetivo desta pesquisa é investigar o comportamento de concretos do ponto de vista da resistência à compressão e absorção de água, quando utilizados com tempo de mistura de até 6 horas. Os concretos foram produzidos com dois tipos de cimento, CPIV e CPII, e o abatimento foi mantido ao longo das 6 horas em mistura com a incorporação de aditivo superplastificante à base policarboxilato. Nesse estudo adotaram-se três relações a/c e a produção dos concretos foi realizada em laboratório e em condição real numa central dosadora de concreto. As propriedades estudadas, resistência à compressão e absorção de água, foram analisadas aos 28 dias para vários tempos de mistura. O estudo mostrou que o tempo para utilização do concreto pode ser estendido acima do tempo especificado pela norma, sem que haja perda de sua resistência à compressão e alterações na absorção de água ao longo do tempo. / The Brazilian standard NBR 7212 (ABNT, 1984), for execution of ready-mixed concrete, specifies the maximum time for concrete to be discharged (used) completely in 150 minutes. The usage time of the concrete is due to reactions of the cement hydration and slump loss that occurs with fresh concrete, a normal phenomenon defined as the loss of fluidity along the time. This property of concrete is particularly important in the case of ready-mixed concrete plants, because the first contact of water with the cement is in the ready-mixed concrete plants while launching / densification occurs minutes or hours later, when the mixer truck arrives at the construction site. In fact, often, there are situations where trucks are loaded with concrete by 4 or 5 hours, due to delays in transportation or unloading, characterizing some time well above the limit specified by the standard. The question is to use or not use the concrete on these conditions, because there are no studies that confirm the final properties of the concrete when used with mixing time that have already exceeded the maximum limit specified by the standard. The aim of this study is to investigate the behavior of concrete from viewpoint of compressive strength and water absorption when used with mixing time up to 6 hours. The concretes were produced with two types of cement, CPIV and CPII, and slump was kept up to the six hours in a mixture with the incorporation of superplasticizer based polycarboxylate. In this study were adopted three relations w/c and the production of concrete was done in laboratory and real conditions in a ready-mixed concrete plants. The studied properties, compressive strength and water absorption were analyzed in 28 days for several mixing times. The study showed that the time of use from the concrete can be extended over the time specified by the standard, without loss of compressive strength and changes in the water absorption over time.
29

Avaliação da resistência à compressão e da absorção de água de concretos utilizados após o tempo máximo de mistura e transporte especificado pela NBR 7212 / Evaluation of compressive strength and water absorption of concrete used after the maximum time of mixing and transport specified by NBR 7212

Polesello, Eduardo January 2012 (has links)
A norma brasileira NBR 7212 (ABNT, 1984), para execução de concreto dosado em central, estipula o tempo máximo para que o concreto seja descarregado (aplicado) completamente em 150 minutos. O tempo para utilização do concreto está vinculado às reações de hidratação do cimento e à perda de abatimento que ocorre com o concreto fresco, um fenômeno normal definido como sendo a perda de fluidez com o passar do tempo. Essa propriedade do concreto é particularmente importante no caso de concreto dosado em centrais, pelo fato do primeiro contato da água com o cimento ser na central enquanto que o lançamento/adensamento ocorrerá alguns minutos ou horas depois, quando o caminhão betoneira chegar ao canteiro de obras. Na prática, muitas vezes, ocorrem situações onde caminhões ficam carregados com concreto por 4 ou 5 horas, em função de atrasos no transporte ou na descarga, caracterizando um tempo bem acima do limite especificado pela norma. A dúvida de utilizar ou não o concreto nessas condições existe, pois não há conhecimento consolidado quanto às suas propriedades finais quando empregado com tempo de mistura que já tenham excedido o limite máximo especificado por norma. O objetivo desta pesquisa é investigar o comportamento de concretos do ponto de vista da resistência à compressão e absorção de água, quando utilizados com tempo de mistura de até 6 horas. Os concretos foram produzidos com dois tipos de cimento, CPIV e CPII, e o abatimento foi mantido ao longo das 6 horas em mistura com a incorporação de aditivo superplastificante à base policarboxilato. Nesse estudo adotaram-se três relações a/c e a produção dos concretos foi realizada em laboratório e em condição real numa central dosadora de concreto. As propriedades estudadas, resistência à compressão e absorção de água, foram analisadas aos 28 dias para vários tempos de mistura. O estudo mostrou que o tempo para utilização do concreto pode ser estendido acima do tempo especificado pela norma, sem que haja perda de sua resistência à compressão e alterações na absorção de água ao longo do tempo. / The Brazilian standard NBR 7212 (ABNT, 1984), for execution of ready-mixed concrete, specifies the maximum time for concrete to be discharged (used) completely in 150 minutes. The usage time of the concrete is due to reactions of the cement hydration and slump loss that occurs with fresh concrete, a normal phenomenon defined as the loss of fluidity along the time. This property of concrete is particularly important in the case of ready-mixed concrete plants, because the first contact of water with the cement is in the ready-mixed concrete plants while launching / densification occurs minutes or hours later, when the mixer truck arrives at the construction site. In fact, often, there are situations where trucks are loaded with concrete by 4 or 5 hours, due to delays in transportation or unloading, characterizing some time well above the limit specified by the standard. The question is to use or not use the concrete on these conditions, because there are no studies that confirm the final properties of the concrete when used with mixing time that have already exceeded the maximum limit specified by the standard. The aim of this study is to investigate the behavior of concrete from viewpoint of compressive strength and water absorption when used with mixing time up to 6 hours. The concretes were produced with two types of cement, CPIV and CPII, and slump was kept up to the six hours in a mixture with the incorporation of superplasticizer based polycarboxylate. In this study were adopted three relations w/c and the production of concrete was done in laboratory and real conditions in a ready-mixed concrete plants. The studied properties, compressive strength and water absorption were analyzed in 28 days for several mixing times. The study showed that the time of use from the concrete can be extended over the time specified by the standard, without loss of compressive strength and changes in the water absorption over time.
30

Avaliação da liberação de monômero residual, absorção de água e porosidade superficial em resinas acrílicas para prótese ocular / Evaluation of residual monomer, water sorption and porosity by acrylic resins used to eye prostheses

Rodrigo Elias de Oliveira 07 March 2008 (has links)
A necessidade do aprimoramento das técnicas de confecção de próteses oculares que permitam satisfazer, com rapidez e excelência, a demanda de atendimento de pacientes portadores de perdas do bulbo ocular, levou ao desenvolvimento deste estudo comparativo no qual se avalia a porosidade superficial, absorção de água e liberação de monômero residual de resinas acrílicas. Foram estabelecidos quatro grupos de estudo, sendo cada grupo composto por 15 corpos de prova: Grupo 1 - resina acrílica termo polimerizável convencional / ciclo térmico convencional; Grupo 2 - resina acrílica termo polimerizável em microondas / ciclo microondas; Grupo 3 - resina acrílica termo polimerizável convencional / ciclo microondas; Grupo 4 - resina acrílica auto polimerizável com cadeia cruzada / auto polimerização. A avaliação da quantidade de monômero residual liberado foi realizada por meio de espectrofotometria, durante o período de 11 dias. A determinação da absorção de água baseou-se na diferença do peso apresentado pelos corpos de prova nas condições experimentais seco e após submersão em água deionizada por um período de 7 dias. A determinação da porosidade superficial foi calculada sob a forma de porcentagem por área de superfície analisada, empregando-se lupa estereoscópica para captação da imagem a ser processada pelo software ImageLab 2000®. Submetendo-se os dados à análise estatística ANOVA/TUKEY (p<=0,05) observou-se que a liberação de monômero residual foi significantemente maior no primeiro dia para o Grupo 1, semelhante durante todo o período para o Grupo 2, menor a partir do dia 8 para o Grupo 3 e decrescente até o dia 8 para o Grupo 4. A liberação de monômero residual foi semelhante para os Grupos 1 e 3, menor para o Grupo 2 e maior para o Grupo 4. A absorção de água foi semelhante para os quatro grupos de estudo. A maior porosidade ocorreu no Grupo 2, sendo os Grupos 1 e 3 semelhantes entre si. Concluiu-se que os ciclos térmicos de polimerização em água e em microondas não interferiram na liberação de monômero residual da resina acrílica termo polimerizável convencional. A liberação de monômero residual variou em função do tipo de resina acrílica. O tipo de resina acrílica e o ciclo de polimerização a que foram submetidas não interferiram na absorção de água. Os ciclos térmicos de polimerização em água e em microondas não interferiram na porosidade apresentada pela resina acrílica termo polimerizável convencional. A porosidade superficial variou em função do tipo de resina acrílica avaliada. / This comparative evaluation of porosity, water sorption and residual monomer presented by acrylic resins was conducted, looking for excellence and rapidity in the confection of eye prostheses. Four groups, comprising of 15 specimens each, were established and submitted to polymerization cycles: Group 1 - conventional heat polymerizing acrylic resin / conventional heat-polymerization cycle; Group 2 - microwave acrylic resin / microwave cycle; Group 3 - conventional heat polymerizing acrylic resin / microwave cycle; Group 4 - cross-linked auto-polymerizing acrylic resin / auto-polymerizing process. Residual monomer liberation was determined by spectrophotometry during 11 days period. Water sorption was calculated by weighting dried specimens and weighting after 7 days of submersion in deionized water. Superficial porosity was determined by percentage of area, in images processed by the software ImageLab 2000®. Subjecting data to ANOVA/TUKEY test (p<=0,05) it was observed that residual monomer liberation was higher in the first day for Group 1, similar during all the period for Group 2, lower after day 8 for Group 3 and decreasing until day 8 for Group 4. Residual monomer liberation was similar to Groups 1 and 3, lower for Group 2 and higher for Group 4. Water sorption was similar to all groups. Group 2 displayed more superficial porosity, and Group 1 and 3 were similar regarding this test. In conclusion, conventional polymerization and microwave processes did not interfere in residual monomer liberation of conventional acrylic resin. The residual monomer liberation varied according the type of acrylic resin. Microwave cycle provided similar or smaller residual monomer liberation. The type of acrylic resin and the polymerization cycle utilized did not modify water sorption. The conventional heat polymerizing cycle and microwave cycle did not interfere in superficial porosity of conventional heat polymerizing acrylic resin. The superficial porosity varied according to the acrylic resin.

Page generated in 0.0546 seconds