• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

ESTUDO DA UTILIZAÇÃO DE CINZA DA CASCA DO ARROZ RESIDUAL EM CONCRETOS ESTRUTURAIS: UMA ANÁLISE DA DURABILIDADE AOS CLORETOS / UTILIZATION STUDY OF RESIDUAL RICE RUSK ASH IN STRUCTURAL CONCRETE: AN ANALYSIS OF THE CHLORIDE DURABILITY

Pedrozo, Eder Claro 27 March 2008 (has links)
The use of residues, as the rice husk ash (RHA) in the concrete s production reduces the environmental impact caused in its productive chain. It means fewer energy s consumption, fewer natural resources waste, less environmental pollution and lower aggregated cost. In the present study, the viability of using residual RHA, in natura (non-ground) or ground, on structural concrete, in partial substitution to the Portland cement was investigated, starting from the durability chloride ions analysis. In such a way, five cementitious blends, two composed by natural RHA, two with crushed RHA and one as a reference sample were tested. The substitution s rates were 15% and 25%. The water/binder relations used were 0.45, 0.55 and 0.65. The samples were tested for chloride penetration according to ASTM C 1202 (Rapid Chloride Permeability Test) and for long-term test (colorimetric method). Additionally, the tests of axial compressive strength and water absorption by immersion, according to the ABNT prescriptions were conducted. The obtained results showed that is viable to use residual non-ground RHA as partial substitution to Portland cement in structural concretes. For the axial compressive strength at 91 days and to the same relation w/b, in general, the residual non-ground RHA blends showed higher performance than those presented by the reference mixture. In the RCPT the use of RHA resulted in decreases in the passing charges that, in general, promoted improvement in the mixtures ratings on the chloride penetrability, compared with the reference mixtures. In long-term test, the use of RHA burnt without temperature control, also promoted improvements in the mixture performances, compared to the reference mixtures, with reductions in the chloride penetration coefficients. But the mixtures were dissimilar when compared to those presented by the RCPT. In the case of water absorption by immersion, it was found that the use of RHA, in general, increased the concrete water absorption, however, the results presented by mixtures composed with RHA were close to those of reference ones. / A utilização de resíduos como a cinza da casca do arroz produzida sem controle da temperatura na fabricação de concretos reduz o impacto ambiental gerado na cadeia produtiva deste material, significando menor consumo de energia, menor desperdício de recursos naturais, menor poluição do meio ambiente e menor custo agregado. No presente trabalho investiga-se a viabilidade de se utilizar a CCA residual, ao natural ou moída, em concretos estruturais, em substituição parcial ao cimento Portland, a partir da análise da durabilidade aos ions cloretos. Para isso, foram testadas cinco misturas aglomerantes: duas compostas com CCA ao natural, duas com CCA moída e uma mistura de referência com 100% cimento Portland, a qual se confrontaram os resultados. Adotaram-se os teores de substituição de 15% e 25%, e as relações a/ag de 0,45; 0,55 e 0,65. Procederam-se os ensaios de resistência à penetração de cloretos segundo o método de penetração acelerada ASTM C 1202 (EAPC) e também, segundo o método de imersão em solução salina (EPCI). Adicionalmente, foram realizados os ensaios de resistência à compressão axial e de absorção de água por imersão, segundo prescrições da ABNT. Os resultados obtidos na investigação confirmam que é viável utilizar a CCA residual, ao natural ou moída, como substituição parcial ao cimento Portland, em concretos para uso estrutural. Quanto à resistência a compressão axial, aos 91 dias, as misturas compostas CCA, em geral, apresentaram desempenhos superiores aos das misturas de referência. No EAPC a utilização de CCA resultou em decréscimos nos valores das cargas passantes que, em geral, promoveram melhoria nas classificações das misturas quanto à penetrabilidade aos cloretos, em comparação as misturas de referência. No EPCI a utilização da CCA, queimada sem controle de temperatura, também promoveu melhorias no desempenho da maioria das misturas, em comparação às misturas de referência, com reduções nos coeficientes de penetração de cloretos. Porém as misturas apresentaram comportamentos diferenciados quando comparados ao apresentado no EAPC. No caso da absorção de água por imersão, constatou-se que a utilização de CCA, em geral, aumentou a absorção de água dos concretos, entretanto, os valores apresentados pelas misturas compostas com CCA foram próximos aos de referência.

Page generated in 0.1144 seconds