• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 42
  • Tagged with
  • 44
  • 44
  • 27
  • 24
  • 13
  • 13
  • 10
  • 8
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Desempenho acústico de sistemas de vedações verticais internas: avaliação de conjuntos de portas e paredes separadas pelo hall de entrada

Scherer, Cláudio Trindade 14 August 2017 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2017-11-30T11:22:21Z No. of bitstreams: 1 Cláudio Trindade Scherer_.pdf: 4509704 bytes, checksum: 6adc0f4eb6a2c5abca0aa3ac53dbcea7 (MD5) / Made available in DSpace on 2017-11-30T11:22:22Z (GMT). No. of bitstreams: 1 Cláudio Trindade Scherer_.pdf: 4509704 bytes, checksum: 6adc0f4eb6a2c5abca0aa3ac53dbcea7 (MD5) Previous issue date: 2017-08-14 / Nenhuma / O conjunto de paredes e portas separadas pela circulação condominial em edifícios residenciais passou a ter seu desempenho acústico avaliado, a partir da entrada em vigor da norma brasileira NBR 15575, que trata do desempenho das edificações. Nesse contexto, esse trabalho propõe determinar a influência das características dos elementos construtivos – portas e circulações entre unidades habitacionais – no isolamento ao ruído aéreo do conjunto de paredes e portas separadas pelo hall de entrada. Primeiramente foi realizado um estudo piloto que envolveu ensaios em campo feitos em diversas obras. Com isso, foram escolhidos três prédios e executados uma série de ensaios de desempenho acústico em campo, abrangendo diversas situações. Também foram usados artifícios para a vedação das frestas das portas, a fim de verificar a melhora do desempenho do sistema. Os resultados obtidos apontam para a perda de desempenho acústico com o aumento das frestas entre a folha da porta e o piso. Foram encontradas também relações com tempo de reverberação dos ambientes de circulação e a distância entre as portas de entrada das unidades habitacionais. / Sets of walls and doors separated by condominium corridors in residential buildings started having their acoustic performance evaluated when the Brazilian standard NBR 15575 came into effect, which concerns the performance of buildings. In this context, this study proposed to determine the influence of the characteristics of constructive elements – doors and corridors between residential units – on the airborne sound insulation of the set of walls and doors separated by the entrance hall. First, a pilot study was conducted based on tests performed on many buildings, but it was noted that a deeper study on the subject would be required. Thereby, three buildings were chosen and a series of acoustic performance tests was executed, covering several situations. Maneuvers for sealing door gaps were used as well, in order to assess the performance gains of the system. The results indicated loss of acoustic performance when there were more gaps between the door leaf and the floor. Moreover, relations were found regarding the reverberation time of the corridors and the distance between the entrance doors of residential units.
32

Relações entre índices urbanísticos da forma urbana e a acústica ambiental

Mendonça, André Bressa Donato 20 November 2013 (has links)
Made available in DSpace on 2016-06-02T20:00:54Z (GMT). No. of bitstreams: 1 5602.pdf: 10130750 bytes, checksum: 9ee73c758568653f6658ccb9f4922372 (MD5) Previous issue date: 2013-11-20 / Financiadora de Estudos e Projetos / Noise pollution in urban areas has been an usual problem in several Brazilian cities. However, this issue does not take into account the urban morphology and its constant changes. Therefore, sound mapping is a helping tool on the matter, allowing the prevention of sound impacts and the recognition of areas under acoustic conflicts. Applying this planning instrument, this research aims at the identification of relations between indexes of urban form and sound pressure levels achieved on street networks, specifically when considering the potential offered by the occupancy rate, the floor space index and the ratio between height and width of the urban roads. The methodology is based on the collection of physical and acoustical data, on the application of a calculation model, named NMPB-Routes 2008 and its respective validation, and on the simulation of a future scenario in the acoustic software CADNA-A. The analyzes were based on the variations of sound pressure levels, which were verified between the current scenario and the future scenario, together with the identification of the relationships between the occupancy rate, the floor space index and the H/W factor, besides the classification of the acoustics conditions of the urban blocks. The results showed that the new buildings of the future scenario contributed up to 1.0 dB (A) in the increase of the sound pressure levels at the height of ten meters above ground level. Furthermore, among the factors studied at the height of four meters, the occupancy rate is the one assuming the highest importance on the increase of sound pressure levels. On the other hand, at ten meters-high, the floor space index achieved the greatest significance in the role played on the increment of noise levels. / A poluição sonora no meio urbano tem sido um problema recorrente em muitas cidades brasileiras. Entretanto, esta problemática não leva em consideração a morfologia urbana e suas constantes modificações. Para isso, o mapeamento sonoro é uma ferramenta de grande auxílio, que permite prevenir impactos sonoros e diagnosticar áreas com conflitos acústicos já existentes. Aplicando esse recurso, essa pesquisa tem por objetivo identificar relações entre índices urbanísticos da forma urbana e os níveis de pressão sonora alcançados em redes viárias, considerando especificamente o potencial oferecido pela taxa de ocupação, índice de aproveitamento e relação entre altura e largura das vias. A metodologia é baseada em levantamento de dados físicos e acústicos do local, aplicação de um modelo de cálculo denominado NMPB-Routes 2008 e sua respectiva validação, além da simulação de um cenário futuro no software acústico CADNA-A. As análises se basearam nas variações dos níveis de pressão sonora, que foram verificadas entre o cenário atual e o cenário futuro, com a identificação das relações entre os coeficientes de ocupação, aproveitamento e da relação H/W; e, a classificação acústica das quadras urbanas. Os resultados apontaram que as novas edificações do cenário futuro contribuem com um incremento de até 1,0 dB(A) nos níveis de pressão sonora para a altura de dez metros acima do nível do solo. Verificouse também que, dentre os coeficientes estudados, o coeficiente de ocupação assume importância maior para a altura de quatro metros, influenciando no incremento dos níveis sonoros. Para alturas a dez metros acima do solo, o coeficiente de aproveitamento se revela como uma relação mais significativa no incremento dos níveis sonoros.
33

Influência acústica de concha orquestral na área da plateia de teatro de múltiplo uso / Acoustic influence of orchestra shell at audience area in a multipurpose theater

Maiorino, Alexandre Virginelli, 1972- 23 August 2018 (has links)
Orientador: Stelamaris Rolla Bertoli / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-23T06:13:27Z (GMT). No. of bitstreams: 1 Maiorino_AlexandreVirginelli_M.pdf: 20810001 bytes, checksum: 874af06d3cad4ebebbbda0ac07b75cd5 (MD5) Previous issue date: 2013 / Resumo: A construção de Teatros para Múltiplo uso tem se tornado cada vez mais comum devido à necessidade de abrigar diversos tipos de espetáculos em um único espaço. Para adequar à acústica destes espaços para a música orquestral é necessário o uso de elementos que possibilitem a variação acústica do espaço como é o caso de conchas de orquestra. O principal objetivo das conchas de orquestra é melhorar a acústica no palco para os músicos e para o maestro, melhorando a sensação de conjunto e fazendo com que os músicos ouçam melhor seus instrumentos e o grupo em geral. Entretanto, a concha de orquestra pode também melhorar o desempenho acústico da área da platéia. A hipótese deste trabalho foi o de analisar a diferença do desempenho acústico percebido na área da platéia devido à inclusão de uma concha de orquestra no palco de um teatro de múltiplo uso. Medições acústicas foram realizadas em cinco diferentes tipos de montagem da concha de orquestra no palco. As medições foram feitas de acordo com a norma ISO 3382-1 (2009). Os parâmetros acústicos medidos foram o Tempo de Reverberação, Tempo Inicial de Decaimento e Índice de Clareza. Os resultados mostraram que a concha de orquestra pode de fato mudar o desempenho acústico na área da platéia, modificando a percepção acústica subjetiva do ambiente / Abstract: The construction of multiple use theatres is becoming more common due to the need to accommodate different kinds of performances at the same space. In order to acoustically adequate this space to concert music, the inclusion of an orchestra shell becomes necessary. The main objective of an orchestra shell is to improve the acoustic quality on stage, both for musicians and for the conductor. The goal is to improve balance of the group allowing musicians to hear themselves and the orchestra better. However, the orchestra shell can also improve the acoustic quality for the audience. The objective of this study was to analyze the difference of the acoustic performance perceived at the audience area with the inclusion of a lightweight orchestra shell with diffuse surface in a proscenium theatre. Acoustic measurements were done in five different assembles of the orchestra shell. Measurements were done using the impulse response technique according to ISO3382-1 (2009). Measured parameters were Reverberation Time, Early Decay Time and Clarity index. Results showed that the orchestra shell can in fact modify the acoustic performance at audience area, changing the subjective acoustic perception of the space / Mestrado / Arquitetura e Construção / Mestre em Engenharia Civil
34

Modelagem computacional para simulação de campo acústico de baixa frequência em salas / Computational modeling to simulate sound field of law frequency in rooms

Ismael Andrade Pimentel 22 August 2008 (has links)
Fundação Carlos Chagas Filho de Amparo a Pesquisa do Estado do Rio de Janeiro / O presente trabalho aborda a modelagem numérica da propagação das ondas sonoras em salas, a partir da avaliação do campo de pressão sonora quadrática na sala. Esta pesquisa apresenta um modelo computacional, baseado na abordagem modal de salas com geometria retangular, que melhora o desempenho do programa de simulação numérica de acústica de salas RAIOS 3 para as baixas frequencias. Inicialmente, foi feita uma análise modal teórica e experimental de uma sala retangular de paredes rígidas e não rígidas, onde se calcula pressão sonora de todos os modos como função da posição e do tempo. Para isso, determinam-se os números de onda e frequência de cada modo, ou seja, os autovalores e as autofrequências. O desempenho do modelo é avaliado a partir dos resultados obtidos com uma sala retangular e validado utilizando dados experimentais do PTB (Physikalisch-Technische Bundesanstalt), Alemanha, na intercomparação denominada Round Robin 3, fase 3. Os principais resultados foram obtidos pelo cálculo dos seguintes parâmetros: tempo de reverberação, (T30), fator de clareza (C80), difinição (D50) e o tempo de decaimento inicial, (EDT). / This article discusses the numerical modeling of the propagation of sound waves in rooms, from the assessment of the field of sound pressure quadratic in the room. This research presents a computational model, based on modal approach of rooms with rectangular geometry, which improves the performance of the program for numerical simulation of acoustics of rooms RAIOS 3 for low frequencies. Initially, there was a theoretical and experimental modal analysis of a rectangular room for non-rigid and rigid walls, where an estimated sound pressure of all modes as a function of place and time. For this, is determining of the wavenumbers and frequencies of each mode, namely the eigenvalues and eigenfrequencies. The performance of the model is assessed from results with a rec tangular room and validated using measurement data of the PTB (Physikalisch-Technische Bundesanstalt), Germany, an inter-comparison named Round Robin 3, phase - 3. The main results were obtained by calculating the following parameters: reverberation time, (T30), clarity factor, (C80), difinition, (D50) and early decay time.
35

Modelagem computacional para simulação de campo acústico de baixa frequência em salas / Computational modeling to simulate sound field of law frequency in rooms

Ismael Andrade Pimentel 22 August 2008 (has links)
Fundação Carlos Chagas Filho de Amparo a Pesquisa do Estado do Rio de Janeiro / O presente trabalho aborda a modelagem numérica da propagação das ondas sonoras em salas, a partir da avaliação do campo de pressão sonora quadrática na sala. Esta pesquisa apresenta um modelo computacional, baseado na abordagem modal de salas com geometria retangular, que melhora o desempenho do programa de simulação numérica de acústica de salas RAIOS 3 para as baixas frequencias. Inicialmente, foi feita uma análise modal teórica e experimental de uma sala retangular de paredes rígidas e não rígidas, onde se calcula pressão sonora de todos os modos como função da posição e do tempo. Para isso, determinam-se os números de onda e frequência de cada modo, ou seja, os autovalores e as autofrequências. O desempenho do modelo é avaliado a partir dos resultados obtidos com uma sala retangular e validado utilizando dados experimentais do PTB (Physikalisch-Technische Bundesanstalt), Alemanha, na intercomparação denominada Round Robin 3, fase 3. Os principais resultados foram obtidos pelo cálculo dos seguintes parâmetros: tempo de reverberação, (T30), fator de clareza (C80), difinição (D50) e o tempo de decaimento inicial, (EDT). / This article discusses the numerical modeling of the propagation of sound waves in rooms, from the assessment of the field of sound pressure quadratic in the room. This research presents a computational model, based on modal approach of rooms with rectangular geometry, which improves the performance of the program for numerical simulation of acoustics of rooms RAIOS 3 for low frequencies. Initially, there was a theoretical and experimental modal analysis of a rectangular room for non-rigid and rigid walls, where an estimated sound pressure of all modes as a function of place and time. For this, is determining of the wavenumbers and frequencies of each mode, namely the eigenvalues and eigenfrequencies. The performance of the model is assessed from results with a rec tangular room and validated using measurement data of the PTB (Physikalisch-Technische Bundesanstalt), Germany, an inter-comparison named Round Robin 3, phase - 3. The main results were obtained by calculating the following parameters: reverberation time, (T30), clarity factor, (C80), difinition, (D50) and early decay time.
36

Aperfeiçoamentos no código computacional RAIOS incluindo aurilização / RAIOS computer code improvements including auralization

José Francisco Lúcio Naranjo 30 April 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho se revisam os principais aperfeiçoamentos implementados no código computacional de simulação numérica de acústica de salas denominado RAIOS. Tais aperfeiçoamentos são divididos em quatro grupos: processo de importação de informação a partir de arquivos DXF; a implementação de novos parâmetros de qualidade acústica, assim como o cálculo do nível de pressão sonora; modificações para lidar com casos de acústica de exteriores (ruído urbano) e por último; inserção do módulo de realidade virtual acústica. Inicialmente, é apresentada uma breve revisão do estado anterior do código computacional RAIOS e, em seguida, os modelos que foram implementados no software. Os resultados obtidos foram precisos e os erros apresentados são justificados através da análise das características dos modelos e métodos adotados pelo simulador. / In this work, the most important improvements implemented in the computer code of numeric simulation of room acoustics, called RAIOS, are presented. These improvements are divided in four groups: Data importation process from DXF files; implementation of new acoustic quality parameters and steady state sound pressure level calculation; modifications in order to deal with cases of open field acoustics (urban noise); and implementation of the acoustic virtual reality module. Initially, a brief overview of the previous version of the computer code RAIOS is done. Then, the background theory of the procedures performed in the source code are presented. The results obtained were accurate and the encountered errors are justified through the characteristics analysis of the models and methods adopted by the simulator.
37

Avaliação de ferramenta de simulação da transmissão sonora para projetos de isolamento acústico em edificações habitacionais

Silva, Renata Costa da 19 July 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In July, 2013, Brazil s new standard, NBR15575:2013, began to require minimum thermal, luminal, structural and acoustical performance levels in new constructions of residential dwellings. Thus, computer programs that simulate the sound transmission in buildings, can serve as important tools for professionals, enabling the verification of virtual acoustic performance of projects, quickly and economically. By being widely used in European countries, they have the database of existing elements and building systems in Europe. From this, this study aimed to evaluate a computational tool of simulation of sound transmission on the reality of Brazilian buildings. Twenty households were selected in the city of Santa Maria - RS, to be measured in situ and then simulated to airborne and impact noise. The residences were chosen according to standard and types of building systems. For greater representation of Brazilian buildings, residences of low, medium and high standards were chosen. The building systems chosen were structural masonry, structural walls with concrete or ceramic block; and reinforced concrete, with walls of hollow brick; all with massive concrete slab. The software used for the simulations was the SONarchitect and all the features and building elements used were entered into the software s database. The values of Lœn,T , Dn,T , and RT per frequency band, and their weighted values Lœn,T,w, Dn,T,w and mean RT were obtained through measurements and simulation. The weighted measured and simulated values were similar, on the other hand, the values obtained by frequency band showed disagreement with the lower frequencies precisely, from 50 Hz to 100 Hz. There was also a relationship of impact sound transmission loss with the area size of the partition, in which there is a significant increase in sound insulation in partitions with larger areas. In addition, coefficients and safety factors were determined for each standard and building system to be applied in the spectra of the simulations, aiming to bring the simulated values closer to the measured ones. Parallel with the evaluation of the computational tool, questionnaires with 150 professionals who develop acoustic projects in the country were applied. This step had as main objective to find out what tools and methods are mostly used by professionals in the development of these projects. From 31 received responses, it was determined that 20.88% of the professionals use a computational tool to develop designs. It was also possible to discover some features such as field of expertise and graduation year, which regions they are located, what kind of projects they develop and if they have already developed projects based on the new standard. / Com a entrada em vigor, em julho de 2013, da nova norma brasileira, NBR 15575:2013, passaram a ser exigidos nas novas construções de uso multifamiliar, níveis mínimos de desempenho, tais como térmico, ilumínico, estrutural e acústico. Dessa maneira, programas computacionais que simulam a transmissão sonora em edificações, podem servir como ferramentas importantes aos profissionais, permitindo a verificação do desempenho acústico virtual dos projetos, de forma rápida e econômica. Por serem amplamente utilizados nos países europeus, possuem banco de dados dos elementos e sistemas construtivos existentes na Europa. A partir disso, esse trabalho teve como objetivo a avaliação de uma ferramenta computacional, de simulação da transmissão sonora, para a realidade das construções brasileiras. Foram selecionadas 20 residências, na cidade de Santa Maria - RS, para serem medidas in loco e depois simuladas, aos ruídos aéreo e de impacto. As residências foram escolhidas, de acordo com padrão e sistemas construtivos. Para maior representatividade das construções brasileiras, foram escolhidas residências do padrão baixo, médio e alto. Os sistemas construtivos escolhidos foram alvenaria estrutural, com paredes de bloco estrutural de concreto ou cerâmico; e concreto armado, com paredes de tijolo vazado; todos com laje maciça de concreto. O programa utilizado para as simulações foi o SONarchitect e todas as características, dos elementos construtivos utilizados, foram inseridos no banco de dados do software. Foram obtidos os valores de Lœn,T , Dn,T,, e TR por banda de frequência, e seus valores ponderados de Lœn,T,w, Dn,T,w e TR médio, nas medições e simulações. Os valores ponderados medidos e simulados foram similares, por outro lado os valores obtidos por banda de frequência apresentaram divergência em relação às frequências mais baixas, precisamente de 50 Hz a 100 Hz. Verificou-se também uma relação da perda de transmissão sonora ao ruído de impacto com o tamanho da área da partição, na qual ocorre um aumento significativo no isolamento sonoro em partições com áreas maiores. Além disso, foram determinados coeficientes e fatores de segurança, para cada padrão e sistema construtivo, a serem aplicados nos espectros das simulações. Com o objetivo de aproximar os valores simulados dos valores medidos. Paralelamente à avaliação da ferramenta computacional, foram aplicados questionários com 150 profissionais que desenvolvem projetos acústicos no país. Essa etapa tinha como objetivo principal descobrir quais ferramentas e métodos são mais utilizados pelos profissionais no desenvolvimento desses projetos. A partir de 31 questionários respondidos, foi possível determinar que 20,88% dos profissionais utilizam alguma ferramenta computacional para desenvolver os projetos. Também foi possível descobrir algumas características desses profissionais como curso e ano de formação, quais as regiões que estão inseridos, que tipo de projetos desenvolvem e se já desenvolveram projetos baseados na nova norma.
38

Avaliação do desempenho acústico de um sistema de construção modular: estudo de caso

Ribeiro, Rodrigo Scoczynski 30 March 2015 (has links)
O objetivo deste trabalho é avaliar o desempenho acústico de um sistema construtivo modular e industrializado por meio do método simplificado de campo indicado pelas normas ABNT NBR 15575-4:2013 e ISO 10052:2004, analisando as vedações verticais internas e externas quanto ao isolamento ao ruído aéreo e as comparando com análises já realizadas em outras edificações de trabalhos conhecidos. A indústria de construção civil, em todo o mundo, encontra-se em um momento dedicado à busca e implementação de estratégias de modernização do setor, a fim de se reduzir os custos e minimizar os desperdícios, investido em construções sustentáveis. Há uma necessidade de estudos baseados nos parâmetros da norma NBR 15575-4:2013 para a devida caracterização das tecnologias construtivas que surgem e ainda são consideradas novidade para o setor. A norma implica em uma série de exigências e recomendações, como por exemplo, o conforto acústico, que será abordado nesse trabalho. A metodologia utilizada foi baseada no método simplificado orientado pela ISO 10052:2004. Foram analisadas duas edificações de 40,0m2 cada. Uma delas é um sobrado, e a outra uma casa térrea. Foram feitas as medições de níveis de pressão sonora nos cômodos e nas fachadas, e as medições do tempo de reverberação dos cômodos. Depois de realizadas as medições foram feitas as análises pelo teste “t” de student. Em comparação com os padrões de outros países, percebeu-se que a norma ABNT NBR 15.575-4:2013 possui valores brandos, e que mesmo assim, as atuais técnicas construtivas brasileiras, em sua maior parte, não conseguem atingi-los. Através dos resultados encontrados, percebeu-se uma eficiência quanto ao isolamento ao ruído aéreo nas edificações modulares e industrializadas quando comparados às edificações de outras técnicas construtivas. Conclui-se, então, que o sobrado e a edificação térrea estão de acordo com os níveis de desempenho estabelecidos pelo norma ABNT NBR 15.575-4:2013. / The objective of this study is evaluate the modular and industrialized building system’s acoustic performance through the simplified field method indicated by ABNT NBR 15575-4:2013 and ISO 10052: 2004, analyzing the internal and external vertical seals for air noise insulation and comparing with previous analyzes in other approaches. The world construction industry is in a dedicated time to the pursuit and implementation of sector modernization strategies in order to reduce costs and minimize waste, invested in sustainable buildings. It’s is necessary studies based on the parameters of NBR 15575-4: 2013 for the proper characterization of building technologies that emerge and are still new to the sector. The standard implies a series of requirements and recommendations, such as the acoustic comfort, which will be addressed in this work. The methodology used was based on the simplified method guided by ISO 10052: 2004. Two buildings were analyzed, with 40,0m2 each. One of them is a two-story house, and the other is a ground floor building. Measurements of sound pressure levels were made in the rooms and on the frontages, and measurements of the reverberation time of rooms. After the measurements were made analyzes with test "t" student. Compared to the standards of other countries, it was realized that the ABNT NBR 15575-4: 2013 has soft values, and that even so, the current Brazilian construction techniques, for the most part, can not reach them. Through these results, it was noticed an efficiency about the isolation airnoise in modular and industrialized buildings compared to buildings of other construction techniques. It follows, then, that the floor and the ground floor building comply with the performance levels established by ABNT NBR 15575-4: 2013.
39

Avaliação do desempenho acústico de um sistema de construção modular: estudo de caso

Ribeiro, Rodrigo Scoczynski 30 March 2015 (has links)
O objetivo deste trabalho é avaliar o desempenho acústico de um sistema construtivo modular e industrializado por meio do método simplificado de campo indicado pelas normas ABNT NBR 15575-4:2013 e ISO 10052:2004, analisando as vedações verticais internas e externas quanto ao isolamento ao ruído aéreo e as comparando com análises já realizadas em outras edificações de trabalhos conhecidos. A indústria de construção civil, em todo o mundo, encontra-se em um momento dedicado à busca e implementação de estratégias de modernização do setor, a fim de se reduzir os custos e minimizar os desperdícios, investido em construções sustentáveis. Há uma necessidade de estudos baseados nos parâmetros da norma NBR 15575-4:2013 para a devida caracterização das tecnologias construtivas que surgem e ainda são consideradas novidade para o setor. A norma implica em uma série de exigências e recomendações, como por exemplo, o conforto acústico, que será abordado nesse trabalho. A metodologia utilizada foi baseada no método simplificado orientado pela ISO 10052:2004. Foram analisadas duas edificações de 40,0m2 cada. Uma delas é um sobrado, e a outra uma casa térrea. Foram feitas as medições de níveis de pressão sonora nos cômodos e nas fachadas, e as medições do tempo de reverberação dos cômodos. Depois de realizadas as medições foram feitas as análises pelo teste “t” de student. Em comparação com os padrões de outros países, percebeu-se que a norma ABNT NBR 15.575-4:2013 possui valores brandos, e que mesmo assim, as atuais técnicas construtivas brasileiras, em sua maior parte, não conseguem atingi-los. Através dos resultados encontrados, percebeu-se uma eficiência quanto ao isolamento ao ruído aéreo nas edificações modulares e industrializadas quando comparados às edificações de outras técnicas construtivas. Conclui-se, então, que o sobrado e a edificação térrea estão de acordo com os níveis de desempenho estabelecidos pelo norma ABNT NBR 15.575-4:2013. / The objective of this study is evaluate the modular and industrialized building system’s acoustic performance through the simplified field method indicated by ABNT NBR 15575-4:2013 and ISO 10052: 2004, analyzing the internal and external vertical seals for air noise insulation and comparing with previous analyzes in other approaches. The world construction industry is in a dedicated time to the pursuit and implementation of sector modernization strategies in order to reduce costs and minimize waste, invested in sustainable buildings. It’s is necessary studies based on the parameters of NBR 15575-4: 2013 for the proper characterization of building technologies that emerge and are still new to the sector. The standard implies a series of requirements and recommendations, such as the acoustic comfort, which will be addressed in this work. The methodology used was based on the simplified method guided by ISO 10052: 2004. Two buildings were analyzed, with 40,0m2 each. One of them is a two-story house, and the other is a ground floor building. Measurements of sound pressure levels were made in the rooms and on the frontages, and measurements of the reverberation time of rooms. After the measurements were made analyzes with test "t" student. Compared to the standards of other countries, it was realized that the ABNT NBR 15575-4: 2013 has soft values, and that even so, the current Brazilian construction techniques, for the most part, can not reach them. Through these results, it was noticed an efficiency about the isolation airnoise in modular and industrialized buildings compared to buildings of other construction techniques. It follows, then, that the floor and the ground floor building comply with the performance levels established by ABNT NBR 15575-4: 2013.
40

Aperfeiçoamentos no código computacional RAIOS incluindo aurilização / RAIOS computer code improvements including auralization

José Francisco Lúcio Naranjo 30 April 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho se revisam os principais aperfeiçoamentos implementados no código computacional de simulação numérica de acústica de salas denominado RAIOS. Tais aperfeiçoamentos são divididos em quatro grupos: processo de importação de informação a partir de arquivos DXF; a implementação de novos parâmetros de qualidade acústica, assim como o cálculo do nível de pressão sonora; modificações para lidar com casos de acústica de exteriores (ruído urbano) e por último; inserção do módulo de realidade virtual acústica. Inicialmente, é apresentada uma breve revisão do estado anterior do código computacional RAIOS e, em seguida, os modelos que foram implementados no software. Os resultados obtidos foram precisos e os erros apresentados são justificados através da análise das características dos modelos e métodos adotados pelo simulador. / In this work, the most important improvements implemented in the computer code of numeric simulation of room acoustics, called RAIOS, are presented. These improvements are divided in four groups: Data importation process from DXF files; implementation of new acoustic quality parameters and steady state sound pressure level calculation; modifications in order to deal with cases of open field acoustics (urban noise); and implementation of the acoustic virtual reality module. Initially, a brief overview of the previous version of the computer code RAIOS is done. Then, the background theory of the procedures performed in the source code are presented. The results obtained were accurate and the encountered errors are justified through the characteristics analysis of the models and methods adopted by the simulator.

Page generated in 0.0604 seconds