• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 13
  • 13
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Desenvolvimento de um programa de controle da qualidade para a tecnologia VMAT

Silva, Ricardo Goulart da 04 November 2013 (has links)
A radioterapia moderna continua evoluindo e trazendo mudanças tecnológicas que envolvem novas modalidades de imagem, novos acessórios de imobilização e novos sistemas para a entrega da dose. Esses avanços possibilitam reduzir a dose recebida pelos tecidos sadios e, consequentemente, diminuem o risco de toxicidade e morbidade. Ao mesmo tempo, maiores doses podem ser prescritas para os volumes tumorais, o que aumenta a probabilidade de controle locorregional. Técnicas tradicionais de IMRT oferecem todas essas vantagens, porém, o tempo de cada sessão de tratamento costuma ser muito longo, principalmente para os casos de cabeça e pescoço. Atualmente, a técnica VMAT é uma realidade em vários centros de referência ao redor do mundo. Essa tecnologia melhorou a eficiência na entrega da dose em relação aos tratamentos convencionais de IMRT, diminuindo o tempo de cada aplicação, e apresenta mais graus de liberdade no processo de otimização do tratamento. A modulação dos feixes de radiação é obtida pela variação simultânea de parâmetros dinâmicos como a taxa de dose, velocidade de gantry e a velocidade das lâminas do sistema de colimação. A alta complexidade associada às novas tendências de tratamento, inevitavelmente, exige um maior rigor em relação aos testes de controle da qualidade que devem ser realizados. Os métodos de comissionamento reportados para a tecnologia RapidArc foram estendidos e adaptados para um acelerador Elekta Synergy através de arquivos que podem ser construídos utilizando o software iComCAT. São apresentados testes específicos para o controle da qualidade da máquina e o processo de validação dosimétrica empregado no sistema de planejamento Monaco. Os parâmetros específicos de lâmina, modelados através do algoritmo Monte Carlo, foram avaliados e os testes do TG 119 foram adaptados para os planejamentos de VMAT. No final é apresentado o programa que foi desenvolvido para o controle da qualidade específico da tecnologia VMAT em aceleradores Elekta. / Modern radiation therapy keeps evolving and the technological changes include new imaging modalities, new patient immobilization devices and new treatment delivery systems. These advances have made it possible to reduce the dose to normal tissue structures and consequently minimize the risk of toxicity and morbidity, while allowing for dose escalation to the tumor volumes, potencially leading to improved locoregional control. Traditional IMRT techniques offer all of these features but the treatment session time is usually long, mainly for the head and neck cases. Currently, the VMAT technique is a reality in reference centers around the world. This technology has improved delivery efficiency over IMRT, decreasing the treatment application time, as this modality introduces extra degrees of freedom in the optimization process. The modulation of the radiation beams is achieved by simultaneous variation of dynamic parameters such as dose rate, gantry speed and leaves speed. The high level of complexity associated to the new treatment trends, inevitably, requires more accuracy and more rigorous quality assurance programs. The commissioning methods reported for the Varian RapidArc system were extended to an Elekta Synergy linear accelerator, using custom files built in the iComCAT software. Specific tests for the machine quality assurance are presented and also the dosimetric validation process applied to the Monaco treatment planning system. The MLC parameters, modeled by the Monte Carlo algorithm, were analyzed and the TG 119 tests were adapted for VMATplanning. In the end, a specific program developed for the VMAT technology for Elekta accelerators is presented.
12

Eletronterapia intraoperatória adjuvante  no carcinoma inicial invasivo de mama: tolerabilidade, satisfação estética e eficiência terapêutica / Adjuvant intraoperative electron-beam therapy for early invasive breast carcinoma: toxicity, therapeutic efficacy and aesthetic satisfaction

Hanna, Samir Abdallah 31 January 2014 (has links)
INTRODUÇÃO: A razão para a radioterapia parcial da mama em comparação ao tratamento convencional da mama inteira baseia-se em 3 pontos: a) cerca de 90% das recidivas locais ocorre na adjacência do tumor primário; b) é possível estabelecer a equivalência de efetividade entre a dose única e o tratamento fracionado convencional; e c) existem dificuldades logísticas, financeiras e emocionais no tratamento fracionado convencional (falta da disponibilidade do aparelho de radioterapia em muitos municípios e desistência de tratamento das mulheres que iniciam a radioterapia convencional). Em maio de 2004 iniciou-se um estudo prospectivo com a eletronterapia intraoperatória adjuvante no carcinoma inicial invasor de mama, porém com sistemática de tratamento diferente de outras técnicas: ao invés de se usar um acelerador linear portátil e dedicado, utilizou-se o acelerador linear estático convencional. Neste trabalho, buscou-se analisar a frequência de complicações imediatas e tardias; o grau de satisfação estética das pacientes com as mamas após o tratamento; e as taxas de sobrevida livre de doença e sobrevida livre de falha local. MÉTODOS: Coletaram-se dados dos prontuários, buscando informações demográficas, do estadiamento inicial, da avaliação histopatológica intraoperatória (margens cirúrgicas e linfonodo sentinela), dados técnicos da eletronterapia e os achados finais em exame de parafina. Além disso, a frequência de complicações imediatas (até um mês de cirurgia) e tardias (depois de um mês), a estética (um ano da cirurgia, usando a escala de Harvard/NSABP/RTOG) e finalmente os índices de sobrevida global e livre de evento. RESULTADOS: Foram incluídas 169 pacientes e destas 35 foram excluídas devido a critérios intraoperatórios (linfonodo sentinela positivo ou margens positivas). Assim, 134 foram analisadas com idade mediana de 57,9 (40-85,4) anos, em um seguimento mediano de 50,6 (1-97,2) meses. Quatro pacientes desenvolveram recidiva local e três tiveram recorrência regional. As estimativas actuariais em 5 anos de sobrevida global, livre de eventos e livre de falha local foram respectivamente 97, 90,5 e 93,6%. A incidência cumulativa de falha local em 5 anos foi de 3,7%. A incidência global de toxicidade aguda foi de 8,2% e tardia de 26,2%. Os resultados estéticos excelentes, bons, regulares e ruins observados foram respectivamente 70,9%, 14,2%, 3,7% e 3,0%. Os tamanhos de colimador utilizados foram 4 cm em 18,7%, 5 cm em 80,6% e 7 cm de 0,7% dos casos. A energia de elétrons escolhida para tratamento foi de 6 MeV em 7,4%, 9 MeV em 52,2%, 12 MeV em 35,8%, 15 MeV em 3,7%, e 18 MeV em 0,7%. Os aceleradores lineares dedicados apresentam opção de energia de elétron variando até 9 MeV. Sendo assim, 40,29% dessa amostra provavelmente seria sub-tratada em equipamentos dedicados, pois foram necessários valores maiores de energia de elétrons para um tratamento adequado. Todas as pacientes fizeram portal-filme para checagem antes do tratamento e em 72,4% o alinhamento entre o disco de proteção e o colimador foi suficiente. No entanto, 27,6% das pacientes tiveram que ter os discos reposicionados. Nenhum caso de infecção no período perihospitalar fora observado. CONCLUSÕES: A eletronterapia intraoperatória com acelerador linear convencional apresentou baixa frequência de complicações e resultados estéticos desfavoráveis, e foi oncologicamente efetiva / INTRODUCTION: The rationale for partial breast radiation therapy when compared to conventional whole breast treatment is based on three points: a) about 90% of local recurrences occur in the adjacent area of the primary tumor, b) it is possible to establish equivalence between the effectiveness of single dose and fractionated conventional treatment, and c) there are logistical, financial and emotional difficulties related to conventional fractionated treatment (lack of availability of radiotherapy facilities in many cities and the high dropout rate of women who start conventional radiotherapy). In May 2004 we started a prospective trial using adjuvant intraoperative electron-beam therapy in early invasive breast cancer, but instead of a dedicated linear accelerator, we used the static conventional linear accelerator. In this study, we aimed to analyze the frequency of early and late complications, the cosmetic satisfaction of patients after treatment, and freedom from disease and local recurrence rates. METHODS: Data were collected from medical records, looking for demographic information, the initial stage, intraoperative and definitive histopathological evaluation of surgical margins and sentinel lymph node, technical data and pathologic staging, and follow-up data. In addition, the frequency of immediate (up to one month of surgery) and late (after one month) complications, aesthetics (one year of surgery, using the scale of Harvard/NSABP/RTOG), and finally the event-free and overal survival were obtained. RESULTS: We included 169 patients and 35 of these were excluded due to intraoperative criteria (positive sentinel lymph nodes or margins). Thus, 134 were analyzed. The median age was 57.9 (40 to 85.4) years and the median follow-up was 50.6 (1 to 97.2) months. Four patients developed local recurrence and three had regional recurrence. The actuarial estimates for overall, event-free, and local failure-free survivals were respectively 97, 90.5, and 93.6%. The crude incidence of local failure at 5 years was 3.7%. The overall incidences of acute and late toxicities were respectively 8.2% and 26.2%. The cosmetic results as excellent, good, fair and bad respectively were observed in 70.9%, 14.2%, 3.7% and 3.0%. Collimator sizes were 4 cm in 18.7%, 5 cm in 80.6%, and 7 cm in 0.7% of cases. The electron energy chosen for treatment was 6 MeV in 7.4%, 9 MeV in 52.2%, 12 MeV in 35.8%, 15 MeV in 3.7% and 18 MeV in 0.7%. The dedicated linear accelerators have electron beam energy ranging up to 9 MeV. Thus, 40.29% of these patients probably would not be treated adequately in dedicated equipment due to the need for higher values of electron energy. All patients underwent portal-film and in 72.4% the alignment between the shielding disc and the collimator was enough. However, in 27.6% of patients it had to be repositioned. No case of infection was observed during perihospitalar time. CONCLUSIONS: Intraoperative electrontherapy using conventional linear accelerator has shown low complications and worsening aesthetics rates, and oncologic efficacy
13

Eletronterapia intraoperatória adjuvante  no carcinoma inicial invasivo de mama: tolerabilidade, satisfação estética e eficiência terapêutica / Adjuvant intraoperative electron-beam therapy for early invasive breast carcinoma: toxicity, therapeutic efficacy and aesthetic satisfaction

Samir Abdallah Hanna 31 January 2014 (has links)
INTRODUÇÃO: A razão para a radioterapia parcial da mama em comparação ao tratamento convencional da mama inteira baseia-se em 3 pontos: a) cerca de 90% das recidivas locais ocorre na adjacência do tumor primário; b) é possível estabelecer a equivalência de efetividade entre a dose única e o tratamento fracionado convencional; e c) existem dificuldades logísticas, financeiras e emocionais no tratamento fracionado convencional (falta da disponibilidade do aparelho de radioterapia em muitos municípios e desistência de tratamento das mulheres que iniciam a radioterapia convencional). Em maio de 2004 iniciou-se um estudo prospectivo com a eletronterapia intraoperatória adjuvante no carcinoma inicial invasor de mama, porém com sistemática de tratamento diferente de outras técnicas: ao invés de se usar um acelerador linear portátil e dedicado, utilizou-se o acelerador linear estático convencional. Neste trabalho, buscou-se analisar a frequência de complicações imediatas e tardias; o grau de satisfação estética das pacientes com as mamas após o tratamento; e as taxas de sobrevida livre de doença e sobrevida livre de falha local. MÉTODOS: Coletaram-se dados dos prontuários, buscando informações demográficas, do estadiamento inicial, da avaliação histopatológica intraoperatória (margens cirúrgicas e linfonodo sentinela), dados técnicos da eletronterapia e os achados finais em exame de parafina. Além disso, a frequência de complicações imediatas (até um mês de cirurgia) e tardias (depois de um mês), a estética (um ano da cirurgia, usando a escala de Harvard/NSABP/RTOG) e finalmente os índices de sobrevida global e livre de evento. RESULTADOS: Foram incluídas 169 pacientes e destas 35 foram excluídas devido a critérios intraoperatórios (linfonodo sentinela positivo ou margens positivas). Assim, 134 foram analisadas com idade mediana de 57,9 (40-85,4) anos, em um seguimento mediano de 50,6 (1-97,2) meses. Quatro pacientes desenvolveram recidiva local e três tiveram recorrência regional. As estimativas actuariais em 5 anos de sobrevida global, livre de eventos e livre de falha local foram respectivamente 97, 90,5 e 93,6%. A incidência cumulativa de falha local em 5 anos foi de 3,7%. A incidência global de toxicidade aguda foi de 8,2% e tardia de 26,2%. Os resultados estéticos excelentes, bons, regulares e ruins observados foram respectivamente 70,9%, 14,2%, 3,7% e 3,0%. Os tamanhos de colimador utilizados foram 4 cm em 18,7%, 5 cm em 80,6% e 7 cm de 0,7% dos casos. A energia de elétrons escolhida para tratamento foi de 6 MeV em 7,4%, 9 MeV em 52,2%, 12 MeV em 35,8%, 15 MeV em 3,7%, e 18 MeV em 0,7%. Os aceleradores lineares dedicados apresentam opção de energia de elétron variando até 9 MeV. Sendo assim, 40,29% dessa amostra provavelmente seria sub-tratada em equipamentos dedicados, pois foram necessários valores maiores de energia de elétrons para um tratamento adequado. Todas as pacientes fizeram portal-filme para checagem antes do tratamento e em 72,4% o alinhamento entre o disco de proteção e o colimador foi suficiente. No entanto, 27,6% das pacientes tiveram que ter os discos reposicionados. Nenhum caso de infecção no período perihospitalar fora observado. CONCLUSÕES: A eletronterapia intraoperatória com acelerador linear convencional apresentou baixa frequência de complicações e resultados estéticos desfavoráveis, e foi oncologicamente efetiva / INTRODUCTION: The rationale for partial breast radiation therapy when compared to conventional whole breast treatment is based on three points: a) about 90% of local recurrences occur in the adjacent area of the primary tumor, b) it is possible to establish equivalence between the effectiveness of single dose and fractionated conventional treatment, and c) there are logistical, financial and emotional difficulties related to conventional fractionated treatment (lack of availability of radiotherapy facilities in many cities and the high dropout rate of women who start conventional radiotherapy). In May 2004 we started a prospective trial using adjuvant intraoperative electron-beam therapy in early invasive breast cancer, but instead of a dedicated linear accelerator, we used the static conventional linear accelerator. In this study, we aimed to analyze the frequency of early and late complications, the cosmetic satisfaction of patients after treatment, and freedom from disease and local recurrence rates. METHODS: Data were collected from medical records, looking for demographic information, the initial stage, intraoperative and definitive histopathological evaluation of surgical margins and sentinel lymph node, technical data and pathologic staging, and follow-up data. In addition, the frequency of immediate (up to one month of surgery) and late (after one month) complications, aesthetics (one year of surgery, using the scale of Harvard/NSABP/RTOG), and finally the event-free and overal survival were obtained. RESULTS: We included 169 patients and 35 of these were excluded due to intraoperative criteria (positive sentinel lymph nodes or margins). Thus, 134 were analyzed. The median age was 57.9 (40 to 85.4) years and the median follow-up was 50.6 (1 to 97.2) months. Four patients developed local recurrence and three had regional recurrence. The actuarial estimates for overall, event-free, and local failure-free survivals were respectively 97, 90.5, and 93.6%. The crude incidence of local failure at 5 years was 3.7%. The overall incidences of acute and late toxicities were respectively 8.2% and 26.2%. The cosmetic results as excellent, good, fair and bad respectively were observed in 70.9%, 14.2%, 3.7% and 3.0%. Collimator sizes were 4 cm in 18.7%, 5 cm in 80.6%, and 7 cm in 0.7% of cases. The electron energy chosen for treatment was 6 MeV in 7.4%, 9 MeV in 52.2%, 12 MeV in 35.8%, 15 MeV in 3.7% and 18 MeV in 0.7%. The dedicated linear accelerators have electron beam energy ranging up to 9 MeV. Thus, 40.29% of these patients probably would not be treated adequately in dedicated equipment due to the need for higher values of electron energy. All patients underwent portal-film and in 72.4% the alignment between the shielding disc and the collimator was enough. However, in 27.6% of patients it had to be repositioned. No case of infection was observed during perihospitalar time. CONCLUSIONS: Intraoperative electrontherapy using conventional linear accelerator has shown low complications and worsening aesthetics rates, and oncologic efficacy

Page generated in 0.0673 seconds