• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 3
  • Tagged with
  • 13
  • 13
  • 8
  • 8
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Desempenho acústico de sistemas de vedações verticais internas: avaliação de conjuntos de portas e paredes separadas pelo hall de entrada

Scherer, Cláudio Trindade 14 August 2017 (has links)
Submitted by JOSIANE SANTOS DE OLIVEIRA (josianeso) on 2017-11-30T11:22:21Z No. of bitstreams: 1 Cláudio Trindade Scherer_.pdf: 4509704 bytes, checksum: 6adc0f4eb6a2c5abca0aa3ac53dbcea7 (MD5) / Made available in DSpace on 2017-11-30T11:22:22Z (GMT). No. of bitstreams: 1 Cláudio Trindade Scherer_.pdf: 4509704 bytes, checksum: 6adc0f4eb6a2c5abca0aa3ac53dbcea7 (MD5) Previous issue date: 2017-08-14 / Nenhuma / O conjunto de paredes e portas separadas pela circulação condominial em edifícios residenciais passou a ter seu desempenho acústico avaliado, a partir da entrada em vigor da norma brasileira NBR 15575, que trata do desempenho das edificações. Nesse contexto, esse trabalho propõe determinar a influência das características dos elementos construtivos – portas e circulações entre unidades habitacionais – no isolamento ao ruído aéreo do conjunto de paredes e portas separadas pelo hall de entrada. Primeiramente foi realizado um estudo piloto que envolveu ensaios em campo feitos em diversas obras. Com isso, foram escolhidos três prédios e executados uma série de ensaios de desempenho acústico em campo, abrangendo diversas situações. Também foram usados artifícios para a vedação das frestas das portas, a fim de verificar a melhora do desempenho do sistema. Os resultados obtidos apontam para a perda de desempenho acústico com o aumento das frestas entre a folha da porta e o piso. Foram encontradas também relações com tempo de reverberação dos ambientes de circulação e a distância entre as portas de entrada das unidades habitacionais. / Sets of walls and doors separated by condominium corridors in residential buildings started having their acoustic performance evaluated when the Brazilian standard NBR 15575 came into effect, which concerns the performance of buildings. In this context, this study proposed to determine the influence of the characteristics of constructive elements – doors and corridors between residential units – on the airborne sound insulation of the set of walls and doors separated by the entrance hall. First, a pilot study was conducted based on tests performed on many buildings, but it was noted that a deeper study on the subject would be required. Thereby, three buildings were chosen and a series of acoustic performance tests was executed, covering several situations. Maneuvers for sealing door gaps were used as well, in order to assess the performance gains of the system. The results indicated loss of acoustic performance when there were more gaps between the door leaf and the floor. Moreover, relations were found regarding the reverberation time of the corridors and the distance between the entrance doors of residential units.
12

Adensamento habitacional na cidade de São Paulo: procedimentos para avaliação de desempenho térmico, acústico e luminoso / Housing densification in the city of São Paulo: procedures for assessing termal, accoustic and luminous performance

Vanessa Valdez Guilhon 24 April 2015 (has links)
Esta pesquisa teve como ponto de partida o viés do adensamento em áreas urbanas consolidadas - dotadas de infraestrutura, serviços urbanos e ofertas de emprego - servindo de alternativa à expansão periférica, apresentando-se como potencial para a produção habitacional e para o adensamento construtivo. E assim, uma questão se fez pertinente: construir com o coeficiente de aproveitamento (C.A.) máximo permitido pela legislação urbana (Plano Diretor Estratégico do município de São Paulo), numa dada área da cidade, é uma garantia do atendimento da qualidade ambiental de seus edifícios? A pesquisa foi estruturada na busca por responder a esta questão. Seu objeto é a implantação dos edifícios residenciais na cidade de São Paulo, dentro do contexto de C.A. máximo permitido pela legislação. Como objetivo tem-se o estabelecimento de procedimentos para avaliação de desempenho térmico, acústico e luminoso das unidades habitacionais dos edifícios implantados na quadra de estudo, em área central da cidade de São Paulo. O método é essencialmente analítico com base na ferramenta de simulação computacional TAO: uma metodologia para implantação de edificação - ênfase no desempenho térmico, acústico, luminoso e energético (ALUCCI, 2007), para a entrada de dados e modelagem da quadra de estudo. O trabalho incluiu procedimentos de levantamento de dados primários através de pesquisa de campo. Como produto da tese tem-se: (I) critérios ambientais que orientarão as escolhas dos arquitetos quanto às distintas alternativas de implantação da edificação no terreno, (II) a flexibilização das decisões de projeto, considerando a realidade local e contemplando, principalmente, as intenções e o partido adotado pelo arquiteto, (III) ao optar por qualquer alternativa de implantação, é possível estimar o desempenho da edificação para todos os critérios de desempenho, (IV) resultados distintos do 1° e do último pavimento tipo, o que aponta a necessidade de projeto de pavimento tipo diferentes, o que ordenará o desenho do edifício, (V) metodologia para avaliação de desempenho térmico, acústico e luminoso do edifício, (VI) proposta de ocupação de quadra e avaliação de desempenho térmico, acústico e luminoso das edificações. / This research took as a starting point the densification of consolidated urban areas - with infrastructure, urban services and jobs - as an alternative to peripheral expansion, posing as potential for housing production and the constructive consolidation. So a question became relevant: Does the use of maximum Floor Area Ratio (FAR) allowed by the urban legislation (Strategic Master Plan of São Paulo) in a given area of the city ensure compliance with environmental quality of its buildings? The research was structured aiming to answer this question. The object of investigation is the implementation of the residential buildings in the city of São Paulo within the maximum FAR allowed by law. The objective has been to establish procedures for assessing thermal, acoustic and luminous performance of housing units in buildings of the study block, in the central area of São Paulo. The method is essentially analytical, based on computational simulation tool TAO: methodology for building\'s site planning to optimize thermal, acoustics, lighting and energy performance (ALUCCI, 2007), for the input of data and modeling study block. The work included collection of primary data through a field survey. As the product of the research we have: (I) environmental criteria to guide the choice of architects among different alternative for site plans, (II) the flexibility of design decisions, considering the local reality and contemplating mainly the approach adopted by the architect, (III) Once the site plan is defined it is possible to estimate the performance of the building for various criteria, (IV) different results of the 1st and last floor type, which points the need for different types of design for the ground floor, (V) methodology for evaluating thermal performance, acoustic and light of buildings, (VI) block site plan proposal and evaluation of its thermal, acoustic and luminous performance.
13

Caracterização de painéis aglomerados com madeira de eucalipto e sólidos granulares de poliuretano / Characterization of particleboards with eucalypt wood and polyurethane granular solids

Rauber, Renata 09 December 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The objective of the present study was to evaluate the performance of particleboards fabricated with different proportions of Eucalyptus grandis Hill ex Maiden wood and polyurethane granular solids from the footwear sector of Três Coroas/RS city, using as a binding agent Elastan 8004/BR®, a pre-polymer modified polyisocyanate MDI based. The proportions of polyurethane granular solids and wood particles used were 0/100, 15/85, 30/70, 45/55 e 60/40% (m/m). The performance of the panels was evaluated by density, moisture content, water absorption and thickness swelling at 2 and 24 hours, tensile strength perpendicular to surface, hardness testing, screw withdrawal, IZOD impact strength, thermal conductivity and acoustic performance in relation to airborne noise. Polyurethane addition caused an increase in dimensional stability of the panels, reducing the values of water absorption and thickness swelling. Tensile strength perpendicular to surface of the panels increased significantly with the increase of polyurethane amount in the composition, indicating adhesion quality between particles of panel and adhesive used. Hardness testing was negatively influenced, indicating that the values decreased with the increasing of polyurethane amount. The highest values of screw withdrawal were found using 30 and 45% (m/m) of polyurethane. The IZOD impact strength of the panels increased with the polyurethane granular solids incorporation in its composition, requiring more energy to break them. The addition of t polyurethane provided a decrease in the values of thermal conductivity of the panels and affected the acoustic performance of the panels in a positive way. / O presente trabalho teve como objetivo avaliar o desempenho de painéis aglomerados confeccionados com diferentes proporções de madeira de Eucalyptus grandis Hill ex Maiden e sólidos granulares de poliuretano provenientes do setor calçadista do município de Três Coroas/RS, utilizando como agente aglomerante 20 partes de Elastan 8004/BR®, um prépolímero de poliisocianato modificado baseado no MDI. As proporções entre sólidos granulares de poliuretano e partículas de madeira empregadas foram 0/100, 15/85, 30/70, 45/55 e 60/40% (m/m). O desempenho dos painéis foi avaliado através da determinação da massa específica, teor de umidade, absorção de água e inchamento em espessura após 2 e 24 horas de imersão, resistência à tração perpendicular à superfície, dureza Janka, resistência ao arrancamento de parafusos, resistência ao impacto IZOD, condutividade térmica e desempenho acústico em relação ao ruído aéreo. O acréscimo de poliuretano ocasionou aumento na estabilidade dimensional dos painéis, diminuindo os valores de absorção de água e inchamento em espessura dos mesmos. A resistência à tração perpendicular à superfície dos painéis aumentou significativamente com o aumento da quantidade de poliuretano em sua composição, indicando a qualidade da adesão entre as partículas de madeira e sólidos granulares de poliuretano e o adesivo utilizado. A dureza Janka foi influenciada de maneira negativa, verificando-se diminuição em seus valores à medida que aumentou a quantidade de poliuretano na composição dos painéis. Os maiores valores de resistência ao arrancamento de parafusos foram encontrados utilizando-se 30 e 45% (m/m) de poliuretano. A resistência dos painéis ao impacto IZOD aumentou com a incorporação de sólidos granulares de poliuretano, sendo necessária maior quantidade de energia para o rompimento dos mesmos. A adição de sólidos granulares de poliuretano proporcionou decréscimo nos valores de condutividade térmica dos painéis e afetou de maneira positiva o desempenho acústico dos mesmos.

Page generated in 0.0702 seconds