• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desempenho da luz natural em ambientes com aberturas voltadas para leste considerando a influência dos usuários

Hazboun, Viviane Diniz 09 May 2018 (has links)
Submitted by Automação e Estatística (sst@bczm.ufrn.br) on 2018-08-01T21:15:25Z No. of bitstreams: 1 VivianeDinizHazboun_DISSERT.pdf: 5267988 bytes, checksum: 03959f7347b43d0dd966eaab29dff2ae (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2018-08-03T00:11:56Z (GMT) No. of bitstreams: 1 VivianeDinizHazboun_DISSERT.pdf: 5267988 bytes, checksum: 03959f7347b43d0dd966eaab29dff2ae (MD5) / Made available in DSpace on 2018-08-03T00:11:56Z (GMT). No. of bitstreams: 1 VivianeDinizHazboun_DISSERT.pdf: 5267988 bytes, checksum: 03959f7347b43d0dd966eaab29dff2ae (MD5) Previous issue date: 2018-05-09 / Conselho Nacional de Desenvolvimento Científico e Tecnológico - CNPq / Esta pesquisa avalia o potencial de aproveitamento da luz natural em escritórios com sistemas de aberturas voltados para Leste considerando o comportamento dos usuários. Apesar dos benefícios e da grande disponibilidade de radiação solar em regiões de baixa latitude, é recorrente a subutilização da luz natural em função da relação entre o sistema de abertura e o comportamento do usuário. O ofuscamento e contraste com o monitor induzem o fechamento das cortinas, gerando insuficiência de luz natural, obstrução do contato com o exterior e aumento do consumo de energia elétrica. Os sistemas de aberturas sombreados são determinados por meio de máscaras de sombra, variados parametricamente quanto ao tamanho da abertura e fator de céu visível (FCV), e simulados para quantificação do desempenho na plataforma integrada Rhinoceros/Grasshopper/DIVA. O comportamento dos usuários é identificado por meio de pesquisa de campo com aplicação de questionários, e categorizado em ativo, passivo e intermediário. A avaliação do desempenho luminoso em função dos usuários é feita por meio de planilhas eletrônicas e os resultados são traduzidos em recomendações projetuais simplificadas. Há potencial de aproveitamento da luz natural e menor influência dos usuários para ambientes com grandes aberturas e sistemas externos móveis. Recomenda-se o aumento do tamanho da abertura e redução do FCV para sistemas de proteção fixos, associados ao comportamento ativo dos usuários para o aumento da profundidade de vão iluminado. Devem ser evitados sistemas sem sombreamento eficaz, pequenas aberturas e alto FCV. / This work evaluates the daylight potential in office rooms with fenestration systems oriented to East considering occupant behavior. Despite the benefits and great availability of solar irradiance in low-latitude zones, it is common to underuse daylight due to the relationship between fenestration systems and occupant behavior. The glare and VDT contrast leads occupants to close the blinds, generating insufficient daylight, obstructed outside view and increasing energy consumption. The shaded systems are determined by shading masks with parametrical variation of window size and visible sky factor (VSF), and are simulated for performance analysis on Rhinoceros/Grasshopper/DIVA platform. The occupant behavior is identified through field research with application of questionnaires, and it is categorized as active, passive and intermediate. The daylight performance considering occupant behavior is evalueted through spreadsheets and the results are translated into simplified design recommendations. There is a potential use of daylight and less influence of occupant behavior for the cases with large windows and mobile external devices. It is recommended to increase the window size and reduce the VSF to fixed shading devices, associated with active users to increase daylight depth. Systems with no shading devices, small windows and high VSF should be avoided.
2

Adensamento habitacional na cidade de São Paulo: procedimentos para avaliação de desempenho térmico, acústico e luminoso / Housing densification in the city of São Paulo: procedures for assessing termal, accoustic and luminous performance

Guilhon, Vanessa Valdez 24 April 2015 (has links)
Esta pesquisa teve como ponto de partida o viés do adensamento em áreas urbanas consolidadas - dotadas de infraestrutura, serviços urbanos e ofertas de emprego - servindo de alternativa à expansão periférica, apresentando-se como potencial para a produção habitacional e para o adensamento construtivo. E assim, uma questão se fez pertinente: construir com o coeficiente de aproveitamento (C.A.) máximo permitido pela legislação urbana (Plano Diretor Estratégico do município de São Paulo), numa dada área da cidade, é uma garantia do atendimento da qualidade ambiental de seus edifícios? A pesquisa foi estruturada na busca por responder a esta questão. Seu objeto é a implantação dos edifícios residenciais na cidade de São Paulo, dentro do contexto de C.A. máximo permitido pela legislação. Como objetivo tem-se o estabelecimento de procedimentos para avaliação de desempenho térmico, acústico e luminoso das unidades habitacionais dos edifícios implantados na quadra de estudo, em área central da cidade de São Paulo. O método é essencialmente analítico com base na ferramenta de simulação computacional TAO: uma metodologia para implantação de edificação - ênfase no desempenho térmico, acústico, luminoso e energético (ALUCCI, 2007), para a entrada de dados e modelagem da quadra de estudo. O trabalho incluiu procedimentos de levantamento de dados primários através de pesquisa de campo. Como produto da tese tem-se: (I) critérios ambientais que orientarão as escolhas dos arquitetos quanto às distintas alternativas de implantação da edificação no terreno, (II) a flexibilização das decisões de projeto, considerando a realidade local e contemplando, principalmente, as intenções e o partido adotado pelo arquiteto, (III) ao optar por qualquer alternativa de implantação, é possível estimar o desempenho da edificação para todos os critérios de desempenho, (IV) resultados distintos do 1° e do último pavimento tipo, o que aponta a necessidade de projeto de pavimento tipo diferentes, o que ordenará o desenho do edifício, (V) metodologia para avaliação de desempenho térmico, acústico e luminoso do edifício, (VI) proposta de ocupação de quadra e avaliação de desempenho térmico, acústico e luminoso das edificações. / This research took as a starting point the densification of consolidated urban areas - with infrastructure, urban services and jobs - as an alternative to peripheral expansion, posing as potential for housing production and the constructive consolidation. So a question became relevant: Does the use of maximum Floor Area Ratio (FAR) allowed by the urban legislation (Strategic Master Plan of São Paulo) in a given area of the city ensure compliance with environmental quality of its buildings? The research was structured aiming to answer this question. The object of investigation is the implementation of the residential buildings in the city of São Paulo within the maximum FAR allowed by law. The objective has been to establish procedures for assessing thermal, acoustic and luminous performance of housing units in buildings of the study block, in the central area of São Paulo. The method is essentially analytical, based on computational simulation tool TAO: methodology for building\'s site planning to optimize thermal, acoustics, lighting and energy performance (ALUCCI, 2007), for the input of data and modeling study block. The work included collection of primary data through a field survey. As the product of the research we have: (I) environmental criteria to guide the choice of architects among different alternative for site plans, (II) the flexibility of design decisions, considering the local reality and contemplating mainly the approach adopted by the architect, (III) Once the site plan is defined it is possible to estimate the performance of the building for various criteria, (IV) different results of the 1st and last floor type, which points the need for different types of design for the ground floor, (V) methodology for evaluating thermal performance, acoustic and light of buildings, (VI) block site plan proposal and evaluation of its thermal, acoustic and luminous performance.
3

Adensamento habitacional na cidade de São Paulo: procedimentos para avaliação de desempenho térmico, acústico e luminoso / Housing densification in the city of São Paulo: procedures for assessing termal, accoustic and luminous performance

Vanessa Valdez Guilhon 24 April 2015 (has links)
Esta pesquisa teve como ponto de partida o viés do adensamento em áreas urbanas consolidadas - dotadas de infraestrutura, serviços urbanos e ofertas de emprego - servindo de alternativa à expansão periférica, apresentando-se como potencial para a produção habitacional e para o adensamento construtivo. E assim, uma questão se fez pertinente: construir com o coeficiente de aproveitamento (C.A.) máximo permitido pela legislação urbana (Plano Diretor Estratégico do município de São Paulo), numa dada área da cidade, é uma garantia do atendimento da qualidade ambiental de seus edifícios? A pesquisa foi estruturada na busca por responder a esta questão. Seu objeto é a implantação dos edifícios residenciais na cidade de São Paulo, dentro do contexto de C.A. máximo permitido pela legislação. Como objetivo tem-se o estabelecimento de procedimentos para avaliação de desempenho térmico, acústico e luminoso das unidades habitacionais dos edifícios implantados na quadra de estudo, em área central da cidade de São Paulo. O método é essencialmente analítico com base na ferramenta de simulação computacional TAO: uma metodologia para implantação de edificação - ênfase no desempenho térmico, acústico, luminoso e energético (ALUCCI, 2007), para a entrada de dados e modelagem da quadra de estudo. O trabalho incluiu procedimentos de levantamento de dados primários através de pesquisa de campo. Como produto da tese tem-se: (I) critérios ambientais que orientarão as escolhas dos arquitetos quanto às distintas alternativas de implantação da edificação no terreno, (II) a flexibilização das decisões de projeto, considerando a realidade local e contemplando, principalmente, as intenções e o partido adotado pelo arquiteto, (III) ao optar por qualquer alternativa de implantação, é possível estimar o desempenho da edificação para todos os critérios de desempenho, (IV) resultados distintos do 1° e do último pavimento tipo, o que aponta a necessidade de projeto de pavimento tipo diferentes, o que ordenará o desenho do edifício, (V) metodologia para avaliação de desempenho térmico, acústico e luminoso do edifício, (VI) proposta de ocupação de quadra e avaliação de desempenho térmico, acústico e luminoso das edificações. / This research took as a starting point the densification of consolidated urban areas - with infrastructure, urban services and jobs - as an alternative to peripheral expansion, posing as potential for housing production and the constructive consolidation. So a question became relevant: Does the use of maximum Floor Area Ratio (FAR) allowed by the urban legislation (Strategic Master Plan of São Paulo) in a given area of the city ensure compliance with environmental quality of its buildings? The research was structured aiming to answer this question. The object of investigation is the implementation of the residential buildings in the city of São Paulo within the maximum FAR allowed by law. The objective has been to establish procedures for assessing thermal, acoustic and luminous performance of housing units in buildings of the study block, in the central area of São Paulo. The method is essentially analytical, based on computational simulation tool TAO: methodology for building\'s site planning to optimize thermal, acoustics, lighting and energy performance (ALUCCI, 2007), for the input of data and modeling study block. The work included collection of primary data through a field survey. As the product of the research we have: (I) environmental criteria to guide the choice of architects among different alternative for site plans, (II) the flexibility of design decisions, considering the local reality and contemplating mainly the approach adopted by the architect, (III) Once the site plan is defined it is possible to estimate the performance of the building for various criteria, (IV) different results of the 1st and last floor type, which points the need for different types of design for the ground floor, (V) methodology for evaluating thermal performance, acoustic and light of buildings, (VI) block site plan proposal and evaluation of its thermal, acoustic and luminous performance.
4

Análise do uso da luz natural em salas de aula : estudo de caso em Aracaju - SE / Investigating the use of daylight in classrooms : a case study in Aracaju - SE

Dias, Amanda Fontes Aragão 28 March 2011 (has links)
The use of daylight brings many advantages, as a better quality lighting, psychophysiological benefits and the outside view. In addition, it minimizes the use of artificial lighting and it contributes to the recent interest in energy efficiency. But, despite the daylight s availability existing in Brazil, especially in its Northeast, and despite the great number of daylighting simulation tools, the concern with its optimization hardly takes part on the inicial design of buidings. This thesis is embedded within this context and it aims to analyze and compare the lighting performance between classrooms, trying to support daylighting in these environments. With the TropLux, the simulation of a standard classroom in the city of Aracaju, state of Sergipe, designated Geometry 1, the simulation of some changes in its characteristics, designated Geometries 2 and 3, and the simulation of new geometries with daylighting systems, designated Geometries 4 and 5, were proceeded. In both cases, the CIE Sky types 1 (overcast), 10 (partly cloudy) and 14 (clear) were considered. To analyze the lighting performance of these geometries, it was created isocurves graphics with percentages of illuminances inside the interval 300 lx < E < 2000 lx. From these isocurves graphics, different behaviours of the geometries under the Sky types analyzed were observed. To compare its performances, the average of illuminance s average, the average of the illuminance s percentages inside the interval above and the maximum and minimum values of the illuminance s average were calculated. These values evidence that isolated interventions in the standard classroom (Geometry 1), like increasing the ceiling reflectance (Geometry 2) or adopting a dropped ceiling plan (Geometry 3), does not contribute with the lighting performance s improvement in the illuminance`s interval considered. Nevertheless, they evidence na evolution in the lighting performance of Geometry 5 in relation to the standard classroom (Geometry 1). / O uso da luz natural traz diversas vantagens, dentre as quais destacam-se uma melhor qualidade da iluminação, benefícios psicofisiológicos e o contato com o meio exterior. Além disso, reduz o uso dos sistemas de iluminação artificial, contribuindo com o recente interesse pela eficiência energética. Mas, apesar da disponibilidade de luz natural existente no Brasil, especialmente na sua região Nordeste, e da existência de ferramentas de simulação computacional da luz natural, a preocupação com a sua otimização dificilmente faz parte da fase inicial de projeto das edificações. É dentro desse contexto que o presente trabalho está inserido, com o objetivo de analisar e comparar o desempenho luminoso entre salas de aula, tentando favorecer o uso da luz natural nesses ambientes. Utilizando-se o TropLux, procedeu-se à simulação de uma sala de aula padrão da cidade de Aracaju, no estado de Sergipe, designada Geometria 1, e de duas salas com alterações de algumas de suas características, designadas Geometrias 2 e 3, além de duas novas geometrias contendo elementos de controle e redirecionamento da luz natural, designadas Geometrias 4 e 5. Em ambos os casos foram considerados os céus CIE 1 (encoberto), 10 (parcialmente encoberto) e 14 (claro). Para a análise do desempenho luminoso das geometrias foram gerados gráficos de isocurvas contendo os percentuais de iluminâncias dentro do intervalo 300 lx < E < 2000 lx. A partir deles, observou-se os diferentes comportamentos das geometrias sob os tipos de céu analisados. Para a comparação entre os seus desempenhos, foram calculadas a média das iluminâncias médias, a média dos percentuais de iluminâncias dentro do intervalo proposto e os valores máximo e mínimo das iluminâncias médias. Tais valores demonstram que intervenções isoladas na sala de aula em estudo (Geometria 1), como o aumento da refletância do teto (Geometria 2) ou a inclusão de um teto rebaixado plano (Geometria 3), não trazem melhorias em relação ao seu desempenho luminoso dentro do intervalo de iluminâncias considerado. Apesar disso, sugerem uma evolução no desempenho luminoso da Geometria 5 em relação à sala de aula em estudo (Geometria 1).
5

Shopping Centers à luz da eficiência

Manfredini, Raquel Sanches 21 February 2017 (has links)
Submitted by Marta Toyoda (1144061@mackenzie.br) on 2017-05-12T20:54:43Z No. of bitstreams: 2 Raquel Sanches Manfredini.pdf: 9326728 bytes, checksum: 108652952a4df8329869e0e3ab68dd07 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Paola Damato (repositorio@mackenzie.br) on 2017-05-16T14:32:20Z (GMT) No. of bitstreams: 2 Raquel Sanches Manfredini.pdf: 9326728 bytes, checksum: 108652952a4df8329869e0e3ab68dd07 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-05-16T14:32:20Z (GMT). No. of bitstreams: 2 Raquel Sanches Manfredini.pdf: 9326728 bytes, checksum: 108652952a4df8329869e0e3ab68dd07 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-02-21 / Fundo Mackenzie de Pesquisa / Since the first shopping had been built in Brasil, it has been modificating over the last 50 years because of cultural, urban and environmental changes that had expand its functions beyong to a comercial centre to a lazer and living places. Because of social, environmental and economical changes those were accentuated by energy crisis at 2001, when “Apagão” happens, and in 2015 by insufficient energy production by hydro power because drought. It was therefore sought to design shopping malls with better quality of internal space and with reduced energy consumption during the operation of the building This research aims to achiving lighting design performance, spatial quality and energy efficiency throught daylight design strategies, when improving the porcentage of areas those are permeated by natural light and its integration to artificial lighting system. There were made some proposals with parametric variations and diferente translucent materials were applied in vertical and horizontal windows of two diferentes typologies, 2 and 4 floors at São Paulo metropolitan region. The assessment of buildings undertook in loco measurements, simulation based-model through ReluxPro and the analysis of the comsumption index of the envelope, defined by RTQ-C Procel of proposals made, in order to indicate the better strategies for design performance and to determine the relation between shape and amount of indoor light. The results showed the possibility of increasing daylight harvesting in both cases beyong to RTQ-C requires, however they are protected using innovative diffused daylight systems. In addition, the vertical openings are essencial to better distribution of light and to create points of interest in tall buildings. / Os shopping centers se modificaram ao longo de 50 anos desde sua implantação no Brasil em função das mudanças culturais, urbanas e ambientais expandindo suas funções além de centro de compras para espaços de convivência e lazer. Em decorrências das necessidades de adequações sociais, ambientais e econômicas agravadas pelas crises energéticas em 2001, quando ocorreu o “Apagão” e novamente em 2015, com a redução de produção energética por hidroelétricas devido à estiagem. Buscou-se assim, projetar shopping centers com melhor qualidade do espaço interno e com redução de consumo de energia durante a operação do edifício. A presente dissertação abordará a iluminação natural como diretriz projetual de melhoria de desempenho luminoso, buscando a qualidade espacial e eficiência energética a partir da ampliação de porcentagem de áreas permeadas pela luz natural e da compatibilização do sistema de iluminação artificial. Foram realizadas propostas projetuais por meio de aplicação de variações paramétricas e de diferentes materiais translúcidos de fechamento nas aberturas verticais e horizontais, em dois edifícios de diferentes tipologias, 2 e 4 pavimentos, na região metropolitana de São Paulo. A avaliação dos edifícios incorporou medições in loco, simulações computacionais com o software ReluxPro e análise do índice de consumo da envoltória definida pelo RTQ-C do selo Procel, das propostas realizadas, a fim de se verificar as relações da forma na permeabilidade de luz e indicar as intervenções de melhor desempenho. Os resultados mostraram a possibilidade de ampliação das porcentagens de aberturas zenitais e verticais em ambos os estudos de caso, além da máxima referida no RTQ-C, no entanto que elas sejam protegidas utilizando-se de elementos de difusão. Observou-se também que aberturas verticais são imprescindíveis na distribuição da luz e na aquisição de pontos de interesse em edifícios altos.

Page generated in 0.0718 seconds