• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Contribution a l'optimisation des memoires analogiques rapides et bas bruit dans les technologies submicroniques. Application aux chaines d'acquisition des trajectometres de la physique des particules

VAUTRIN, Florent 20 November 2000 (has links) (PDF)
Le domaine de la physique des particules necessite l'acquisition continue de donnees dans des memoires analogiques constituees de plusieurs millions de cellules de memorisation. Une cellule de memorisation etant un simple echantillonneur-bloqueur. Les contraintes imposees par l'environnement sur ces cellules sont drastiques. Un compromis entre surface, precision, vitesse et puissance dissipee est a trouver. L'etude peut se generaliser au domaine instrumental ou la non-linearite est la principale limitation a l'integration des systemes. L'etude presente e porte sur l'analyse quantitative de la non-linearite dans une cellule minimaliste en mode tension et en mode courant. Afin de determiner la precision ultime que l'on peut atteindre avec une structure minimaliste, des modeles polynomiaux ont ete etablis a partir des equations grands signaux des composants. L'etude des coefficients des polynomes a permis de degager des facteurs d'influence relatifs aux composants de la cellule. Ces modeles ont ete confrontes a des resultats de simulations et un circuit prototype a ete concu dans une technologie 0,25um afin de faire la correlation avec des resultats de mesures. Une resolution de 12 bits peut etre facilement obtenue en mode tension alors que 9 bits sont atteints en mode courant. Il est montre que le mode tension est beaucoup plus sensible aux parametres technologiques. Le mode courant apparait alors comme une alternative interessante pour la conception de memoires analogiques precises dans des technologies fortement submicroniques. Une description complete de l'elaboration des modeles et de leur exploitation est donnee dans ce manuscrit.
2

Techniques d'acquisitions et reconstructions IRM rapides pour améliorer la détection du cancer du sein / Rapid MRI acquisition and reconstruction techniques to improve breast cancer detection

Poujol, Julie 31 May 2017 (has links)
Le cancer du sein est aujourd’hui le cancer le plus fréquent chez la femme ainsi que la première cause de décès féminin par cancer. Actuellement, l’IRM mammaire n’est réalisée qu’en seconde intention lorsque les autres modalités d’imagerie ne suffisent pas à poser un diagnostic. Dans le cas des populations à risque, l’IRM mammaire est recommandée comme examen de dépistage annuel en raison de sa très haute sensibilité de détection. Par IRM, la détection d’un cancer du sein se fait à la suite de l’injection d’un produit de contraste qui permet de visualiser les lésions mammaires en hypersignal. La majeure partie du diagnostic repose sur l’analyse morphologique de ces lésions ; une acquisition hautement résolue spatialement est donc nécessaire. Malgré l’utilisation des techniques d’accélération courantes, le volume de données à acquérir reste important et la résolution temporelle de l’examen d’IRM mammaire est aujourd’hui aux alentours d’une minute. Cette faible résolution temporelle limite donc intrinsèquement la spécificité de l’examen d’IRM mammaire. Un examen avec une haute résolution temporelle permettrait l’utilisation de modèles pharmacocinétiques donnant accès à des paramètres physiologiques spécifiques des lésions. L’approche proposée dans ce travail de thèse est le développement d’une séquence IRM permettant à la fois la reconstruction classique d’images, telle que celle utilisée en routine clinique pour le diagnostic, ainsi qu’une reconstruction accélérée d’images avec une plus haute résolution temporelle permettant ainsi l’application de modèles pharmacocinétiques. Le développement de cette séquence a été réalisé en modifiant l’ordre d’acquisition du domaine de Fourier de la séquence utilisée en clinique, afin qu’il soit aléatoire et permette la reconstruction a posteriori de domaines sous-échantillonnés acquis plus rapidement. Des acquisitions sur des objets tests, sur des volontaires et sur des patientes ont montré que l’acquisition aléatoire ne modifiait pas les images obtenues par reconstruction classique permettant ainsi le diagnostic conventionnel. Une attention particulière a été portée pour permettre la suppression de graisse nécessaire à l’acquisition des images d’IRM mammaire. Les reconstructions des domaines sous-échantillonnés sont réalisées via des reconstructions Compressed Sensing permettant la suppression des artéfacts de sous-échantillonnage. Ces reconstructions Compressed Sensing ont été développées et testées sur des fantômes numériques reproduisant des IRMs mammaires. Le potentiel de cette nouvelle acquisition a enfin été testé sur une lésion artificielle mammaire, développée à cet effet, et reproduisant des prises de contraste mammaires / Breast cancer is nowadays the first cause of female cancer and the first cause of female death by cancer. Breast MRI is only performed in second intention when other imaging modalities cannot lead to a confident diagnosis. In high risk women population, breast MRI is recommended as an annual screening tool because of its higher sensitivity to detect breast cancer. Breast MRI needs contrast agent injection to visualize enhancing lesions and the diagnosis is mostly based on morphological analysis of these lesions. Therefore, an acquisition with high spatial resolution is needed. Despite the use of conventional MRI acceleration techniques, the volume of data to be acquired remains quite large and the temporal resolution of the exam is around one minute. This low temporal resolution may be the cause of the low specificity of breast MRI exam. Breast MRI with higher temporal resolution will allow the use of pharmacokinetic models to access physiological parameters and lesion specifications. The main aim of this work is to develop a MRI sequence allowing a flexible use of the acquired data at the reconstruction stage. On the one hand, the images can be reconstructed with a conventional reconstruction like the protocol used in clinical routine. On the other hand, the new MRI sequence will also allow the reconstruction of images with a higher temporal resolution allowing the use of pharmacokinetic models. The development of this sequence was done by modifying the acquisition order in the Fourier domain. A random acquisition of the Fourier domain will allow the reconstruction of sub-sampled domains acquired faster. We paid attention to fat suppression efficiency with this new Fourier domain acquisition order. Tests were performed on phantom, female volunteers and patients. These tests showed that the random acquisition did not impact the quality of images (MRI signal and lesion morphology) obtained by conventional reconstruction thus allowing the conventional diagnosis. The reconstructions of the sub-sampled Fourier domains were made using Compressed Sensing reconstructions to remove sub-sampling artifacts. These reconstructions were developed and tested on digital phantoms reproducing breast MRI. The potential of this new MRI acquisition was tested on an artificial enhancing breast lesion developed especially for this purpose
3

Concept de radars novateurs pour la vision à travers les milieux opaques / Innovative radar concept for through-the-wall applications

Merelle, Vincent 19 September 2018 (has links)
La « vision » à travers les milieux opaques (murs, cloisons, décombres, ou plus généralement tout milieu qui occulte la vision humaine) est l’un des problèmes clefs du contrôle et de la sécurité. Il apparaît à l’heure actuelle un réel besoin de disposer de dispositifs d’observation à travers ces milieux pour des applications tant militaires (lors des assauts, des prises d’otages, etc.) que civiles (recherche de personnes enfouies dans des décombres, dans un incendie, etc). Les avancées sur cette problématique ont conduit à mettre en place des systèmes radars à très courte portée, opérationnels pour la détection et le tracking de personnes dans des environnements simples. Cependant ils nécessitent que les cibles soient en déplacement afin de les différencier des objets statiques. Cette limitation constitue un défaut majeur pour un certain nombre de scénarii réels où des personnes, par stratégie ou par contrainte, restent immobiles. Ces travaux de thèse visent à explorer les mécanismes de détection de personnes statiques par le biais de leurs micro-mouvements, e.g. des mouvements induits par le thorax lors de la respiration. Nous avons étudié - d’un point de vue théorique - les principes physiques sous-jacents à la détection de ces micro-mouvements par radar UWB impulsionnel à partir du mécanisme Doppler impulsionnel. Ce dernier s’appuie sur des mesures consécutives des phases des impulsions réfléchies. La compréhension de ce phénomène a permis de définir une architecture radar impulsionnelle et de la positionner, en termes de contributions, au regard des différents radars UWB proposés dans la littérature : le FMCW et le radar de bruit. Deux dispositifs radars ont servi de support à ce travail. Le premier, de type démonstrateur académique, repose sur l’utilisation d’un oscilloscope rapide pour numériser les impulsions UWB de 3 à 6 GHz de bande. Il a permis de mettre en place une chaîne de traitement complète de vision à travers les murs. Le second dispositif est un prototype radar développé autour d’une plateforme de numérisation ultra-rapide (100 Gsps par échantillonnage équivalent) de fréquence de rafraîchissement très élevée (100 Hz). Il est construit autour d’un FPGA, d’un ADC rapide (1,25 GHz) et d’un T&H très large bande (18 GHz). Il permet ainsi la détection des micro-mouvements par traitement Doppler impulsionnel. / "Vision" through opaque environments (walls, partitions, rubble, or any environment that obscures human vision) is one of the key issues of control and security. Advances on this issue have led to operational shortrange radar systems for people detection and tracking in simple environments. However, most of them require the targets to move in order to differentiate them from static objects. This requirement constitues a major shortcoming for a certain number of real scenarios where people, by strategies or by constraints, remain motionless. Hence, this thesis aims to explore the mechanisms of detection of static people through their micro-movements, e.g. movements induced by the thorax during breathing. We have studied - from a theoretical point of view - the physical principles underlying the detection of these micro-movements by pulsed UWB radar with the pulsed Doppler phenomenon, which relies on consecutive measurements of the reflected pulses phases. The understanding of this phenomenon made it possible to define a radar architecture and to position it, in terms of contributions, with regard to the different UWB radars proposed in the literature : the FMCW and the noise radar. Two radar devices served as support for this work. An academic demonstrator based on the use of a fast oscilloscope to digitize the pulses. It allowed to set up a complete processing chain for the application of vision through the walls. The second device is a radar prototype developed around a high-speed scanning platform (100 Gsps perequivalent sampling) with a very high refresh rate (100 Hz). This prototype is built around an FPGA, a fast ADC (1.25 GHz) and a very wide band T&H (18 GHz). This thereby enables to detect micro-movements by pulsed Doppler processing.

Page generated in 0.0947 seconds