• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Remoção de cistos de Giardia spp. e de Cryptosporidium spp. em sistema de tratamento de esgoto sanitário: quantificação em fases líquida e sólida / Removal of Giardia spp. cysts and Cryptosporidium spp. oocists in wastewater treatment systems: quantification in liquid and solid fases

Santos, Eraldo Kobayashi dos 25 September 2015 (has links)
No atual cenário de saneamento, há uma escassez de estudos na temática de retenção de microrganismos patogênicos em estações de tratamento de esgotos, onde os principais tratamentos se baseiam na remoção de parâmetros físico-químicos. Uma abordagem mais ampla na remoção destes microrganismos em estações de tratamento e sua quantificação no lodo retido é um passo importante para o aumento do debate acerca da eficiência dos atuais tratamentos utilizados na retenção de patógenos, diminuindo assim a contaminação de corpos d\'água com posteriores problemáticas no âmbito de saúde pública. Desta forma, a proposta do projeto foi avaliar e quantificar a remoção de cistos de Giardia spp., oocistos de Cryptosporidium spp. e Escherichia Coli em sistema de tratamento de esgoto sanitário constituído de tratamento anaeróbio (reator UASB), utilizando dois valores de TDH - 8 horas (Etapa 1) e 12 horas (Etapa 2) - seguido de tratamento em sistema de lodo ativado. O projeto utilizou uma estação de tratamento piloto junto a estação de tratamento da USP São Carlos. Para análises de E. coli e coliformes totais foi utilizada a técnica de pour plate e para detecção de cistos e oocistos de Giardia spp. e Cryptosporidium spp., a técnica de separação imunomagnética (IMS) e técnica de Reação de Imunoflorescência Direta (RID) foi escolhida como método de detecção e quantificação. Para a remoção no reator UASB, a variação de TDH indicou influência na remoção de parâmetros físico-químicos e na retenção de microrganismos, sendo que a utilização de TDH de 12 horas obteve remoções de 0,21 log para cistos Giardia spp. e 0,48 log para oocistos de Cryptosporidium spp. Para o Sistema de Lodo ativado, as remoções foram de 0,48 log e 0,15 para ambos os microrganismos, respectivamente, não havendo influência significativa na retenção com a mudança de TDH do reator UASB. Nas análises em fase sólida, foram observados valores altos de contaminação no lodo, tanto para Giardia spp., quanto para Cryptosporidium spp., onde a viabilidade dos (oo)cistos detectados estiveram na faixa de 30% a 99% nas amostras analisadas. / Currently, the field of sanitation faces a lack of studies on retention of pathogenic microorganisms in wastewater treatment plants, where main treatments are based on the removal of physical and chemical parameters. A broader approach to the removal of pathogens in wastewater treatment systems and their quantification in retained sludge is an important step to increase the debate around the efficiency of prevailing treatments used to retain those microorganisms and to consequently reduce the contamination of water bodies. The present study was conducted to assess and quantify the removal of Giardia spp. cysts, Cryptosporidium spp. oocysts and E. coli in wastewater treatment systems. For the purpose of this research, the treatment consisted of a UASB reactor using two values of hydraulic retention time (HRT) - 8 hours (phase 1) and 12 hours (phase 2) - followed by an activated sludge system. The project was staged in a pilot wastewater treatment plant coupled to USP Sao Carlos\' wastewater treatment system. Pour plate technique was used for analysis of E.coli and total coliforms. IMS was used to detect cysts and oocysts of Giardia spp. and Cryptosporidium spp. DFA (direct immunofluorescence assay) method was chosen to detection and quantification. HRT variation for removal in UASB reactor indicated influence in removal of physical and chemical parameters and in retention of microorganisms. The 12 hours use of HRT obtained removals of 0.21 log for Giardia cysts and 0.48 log for Cryptosporidium oocysts. Activated sludge removals presented 0.48 log and 0.15 log respectively, without significative influence in retention with the HRT\'s change in UASB reactor. High values of contamination were observed during solid-phase analysis in activated sludge, both for Giardia and Cryptosporidium. Here, viability of the (oo)cysts detected was around 30% up to 99% of the analyzed samples.
2

Simulação do co-tratamento de resíduo de tanque séptico em estação de tratamento de esgoto doméstico

Pistorello, Josiane January 2018 (has links)
O presente trabalho avaliou a possibilidade de receber e tratar resíduo de tanques sépticos num sistema dimensionado para tratar esgoto doméstico. Neste sentido, o objetivo deste estudo foi avaliar o co-tratamento deste resíduo numa estação de tratamento de esgoto composta por processo de lodos ativados. Para a realização desta avaliação utilizou-se o modelo matemático ASM1 e o software WRc Stoat 5.0. O modelo ASM1 descreve a remoção de matéria orgânica carbonácea, a nitrificação e a desnitrificação. Para atender ao objetivo proposto, foram realizadas simulações de quatro grupo de cenários, sendo que em cada grupo a ETE operava com uma vazão fixa e foi alterada a parcela de resíduo de tanque séptico a ser tratada no sistema. Para a realização das simulações, previamente realizou-se a estruturação do modelo matemático ao sistema de tratamento selecionado, ajustes dos coeficientes estequiométricos e parâmetros cinéticos e determinaram-se as concentrações de entrada e o fracionamento da DQO e do nitrogênio para o esgoto bruto e para o resíduo de tanque séptico. As simulações geraram como resultado a possibilidade de, num sistema dimensionado para uma vazão média de 180 m3/h e operado com uma vazão de 45 m3/h de esgoto doméstico receber 4,3 m3/h de resíduo de tanque séptico sem comprometer os padrões de lançamento. Já, no caso da mesma ETE operando com 90 m3/h, 135 m3/h e 162 m3/h, as parcelas possíveis de serem recebidas de resíduo de tanque séptico e concomitantemente atendendo aos padrões de lançamento definidos na legislação foram 3,6 m3/h, 3,3 m3/h e 2,9 m3/h. Os resultados obtidos permitem concluir que é viável co-tratar resíduo de tanque séptico com o esgoto doméstico e ao mesmo tempo atender aos padrões de lançamento definidos na legislação, desde que respeitados os fatores limitantes e as cargas máximas. O recebimento e o tratamento do resíduo de tanque séptico em sistemas projetados para esgoto doméstico mostram-se como práticas que podem ser implantados na gestão dos sistemas de esgotamento sanitário. Esta aplicação poderia contribuir para ampliar a correta destinação dos esgotos e consequentemente com a melhoria dos índices de atendimento do esgotamento sanitário. / The present work evaluated the possibility of receiving and treating septic tank residue in a system designed to treat domestic sewage. Therefore, the objective of this study was to evaluate the co-treatment of this residue in a sewage treatment plant with an activated sludge process. The ASM1 model and software WRc Stoat 5.0 were used to perform this evaluation. The ASM1 model describes the removal of carbonaceous organic matter, nitrification and denitrification processes. To attend the proposed objective, simulations of four scenarios group were realized and in each group the system operated with a fixed flow and was changed the portion of septic tank residue. Before running the simulations, the mathematical model was structured to the selected treatment system, adjustments of the stoichiometric coefficients and kinetic parameters and were determined the inputs and fractionations concentration of the COD and nitrogen for the sewage and the septic tank residue. The simulation results show that is possible, in a system designed for an average flow of 180 m3/h and underloaded with a domestic sewage flow of 45 m3/h to receive 4.3 m3/h of septic tank residue without compromising the standards. For systems operating at 90 m3/h, 135 m3/h and 162 m3/h, the possible parcels to be received from septic tank residue without compromising standards defined in the legislation were, respectively, 3.6 m3/h, 3.3 m3/h and 2.9 m3/h. The results allow the conclusion that it is feasible to co-treat septic tank residue with domestic sewage and at the same time respect the standards defined in the legislation, once the limiting flowrates and maximum loads are respected. The acceptance and treatment of septic tank residue in systems designed for domestic sewage are practices that can be implemented in the management of sanitary sewage systems. That can be enplaned to improve the management of sewage systems, therefore, expanding the correct destination of wastewater and consequently contribute to the improvement of sanitary sewage index.
3

Simulação do co-tratamento de resíduo de tanque séptico em estação de tratamento de esgoto doméstico

Pistorello, Josiane January 2018 (has links)
O presente trabalho avaliou a possibilidade de receber e tratar resíduo de tanques sépticos num sistema dimensionado para tratar esgoto doméstico. Neste sentido, o objetivo deste estudo foi avaliar o co-tratamento deste resíduo numa estação de tratamento de esgoto composta por processo de lodos ativados. Para a realização desta avaliação utilizou-se o modelo matemático ASM1 e o software WRc Stoat 5.0. O modelo ASM1 descreve a remoção de matéria orgânica carbonácea, a nitrificação e a desnitrificação. Para atender ao objetivo proposto, foram realizadas simulações de quatro grupo de cenários, sendo que em cada grupo a ETE operava com uma vazão fixa e foi alterada a parcela de resíduo de tanque séptico a ser tratada no sistema. Para a realização das simulações, previamente realizou-se a estruturação do modelo matemático ao sistema de tratamento selecionado, ajustes dos coeficientes estequiométricos e parâmetros cinéticos e determinaram-se as concentrações de entrada e o fracionamento da DQO e do nitrogênio para o esgoto bruto e para o resíduo de tanque séptico. As simulações geraram como resultado a possibilidade de, num sistema dimensionado para uma vazão média de 180 m3/h e operado com uma vazão de 45 m3/h de esgoto doméstico receber 4,3 m3/h de resíduo de tanque séptico sem comprometer os padrões de lançamento. Já, no caso da mesma ETE operando com 90 m3/h, 135 m3/h e 162 m3/h, as parcelas possíveis de serem recebidas de resíduo de tanque séptico e concomitantemente atendendo aos padrões de lançamento definidos na legislação foram 3,6 m3/h, 3,3 m3/h e 2,9 m3/h. Os resultados obtidos permitem concluir que é viável co-tratar resíduo de tanque séptico com o esgoto doméstico e ao mesmo tempo atender aos padrões de lançamento definidos na legislação, desde que respeitados os fatores limitantes e as cargas máximas. O recebimento e o tratamento do resíduo de tanque séptico em sistemas projetados para esgoto doméstico mostram-se como práticas que podem ser implantados na gestão dos sistemas de esgotamento sanitário. Esta aplicação poderia contribuir para ampliar a correta destinação dos esgotos e consequentemente com a melhoria dos índices de atendimento do esgotamento sanitário. / The present work evaluated the possibility of receiving and treating septic tank residue in a system designed to treat domestic sewage. Therefore, the objective of this study was to evaluate the co-treatment of this residue in a sewage treatment plant with an activated sludge process. The ASM1 model and software WRc Stoat 5.0 were used to perform this evaluation. The ASM1 model describes the removal of carbonaceous organic matter, nitrification and denitrification processes. To attend the proposed objective, simulations of four scenarios group were realized and in each group the system operated with a fixed flow and was changed the portion of septic tank residue. Before running the simulations, the mathematical model was structured to the selected treatment system, adjustments of the stoichiometric coefficients and kinetic parameters and were determined the inputs and fractionations concentration of the COD and nitrogen for the sewage and the septic tank residue. The simulation results show that is possible, in a system designed for an average flow of 180 m3/h and underloaded with a domestic sewage flow of 45 m3/h to receive 4.3 m3/h of septic tank residue without compromising the standards. For systems operating at 90 m3/h, 135 m3/h and 162 m3/h, the possible parcels to be received from septic tank residue without compromising standards defined in the legislation were, respectively, 3.6 m3/h, 3.3 m3/h and 2.9 m3/h. The results allow the conclusion that it is feasible to co-treat septic tank residue with domestic sewage and at the same time respect the standards defined in the legislation, once the limiting flowrates and maximum loads are respected. The acceptance and treatment of septic tank residue in systems designed for domestic sewage are practices that can be implemented in the management of sanitary sewage systems. That can be enplaned to improve the management of sewage systems, therefore, expanding the correct destination of wastewater and consequently contribute to the improvement of sanitary sewage index.
4

Simulação do co-tratamento de resíduo de tanque séptico em estação de tratamento de esgoto doméstico

Pistorello, Josiane January 2018 (has links)
O presente trabalho avaliou a possibilidade de receber e tratar resíduo de tanques sépticos num sistema dimensionado para tratar esgoto doméstico. Neste sentido, o objetivo deste estudo foi avaliar o co-tratamento deste resíduo numa estação de tratamento de esgoto composta por processo de lodos ativados. Para a realização desta avaliação utilizou-se o modelo matemático ASM1 e o software WRc Stoat 5.0. O modelo ASM1 descreve a remoção de matéria orgânica carbonácea, a nitrificação e a desnitrificação. Para atender ao objetivo proposto, foram realizadas simulações de quatro grupo de cenários, sendo que em cada grupo a ETE operava com uma vazão fixa e foi alterada a parcela de resíduo de tanque séptico a ser tratada no sistema. Para a realização das simulações, previamente realizou-se a estruturação do modelo matemático ao sistema de tratamento selecionado, ajustes dos coeficientes estequiométricos e parâmetros cinéticos e determinaram-se as concentrações de entrada e o fracionamento da DQO e do nitrogênio para o esgoto bruto e para o resíduo de tanque séptico. As simulações geraram como resultado a possibilidade de, num sistema dimensionado para uma vazão média de 180 m3/h e operado com uma vazão de 45 m3/h de esgoto doméstico receber 4,3 m3/h de resíduo de tanque séptico sem comprometer os padrões de lançamento. Já, no caso da mesma ETE operando com 90 m3/h, 135 m3/h e 162 m3/h, as parcelas possíveis de serem recebidas de resíduo de tanque séptico e concomitantemente atendendo aos padrões de lançamento definidos na legislação foram 3,6 m3/h, 3,3 m3/h e 2,9 m3/h. Os resultados obtidos permitem concluir que é viável co-tratar resíduo de tanque séptico com o esgoto doméstico e ao mesmo tempo atender aos padrões de lançamento definidos na legislação, desde que respeitados os fatores limitantes e as cargas máximas. O recebimento e o tratamento do resíduo de tanque séptico em sistemas projetados para esgoto doméstico mostram-se como práticas que podem ser implantados na gestão dos sistemas de esgotamento sanitário. Esta aplicação poderia contribuir para ampliar a correta destinação dos esgotos e consequentemente com a melhoria dos índices de atendimento do esgotamento sanitário. / The present work evaluated the possibility of receiving and treating septic tank residue in a system designed to treat domestic sewage. Therefore, the objective of this study was to evaluate the co-treatment of this residue in a sewage treatment plant with an activated sludge process. The ASM1 model and software WRc Stoat 5.0 were used to perform this evaluation. The ASM1 model describes the removal of carbonaceous organic matter, nitrification and denitrification processes. To attend the proposed objective, simulations of four scenarios group were realized and in each group the system operated with a fixed flow and was changed the portion of septic tank residue. Before running the simulations, the mathematical model was structured to the selected treatment system, adjustments of the stoichiometric coefficients and kinetic parameters and were determined the inputs and fractionations concentration of the COD and nitrogen for the sewage and the septic tank residue. The simulation results show that is possible, in a system designed for an average flow of 180 m3/h and underloaded with a domestic sewage flow of 45 m3/h to receive 4.3 m3/h of septic tank residue without compromising the standards. For systems operating at 90 m3/h, 135 m3/h and 162 m3/h, the possible parcels to be received from septic tank residue without compromising standards defined in the legislation were, respectively, 3.6 m3/h, 3.3 m3/h and 2.9 m3/h. The results allow the conclusion that it is feasible to co-treat septic tank residue with domestic sewage and at the same time respect the standards defined in the legislation, once the limiting flowrates and maximum loads are respected. The acceptance and treatment of septic tank residue in systems designed for domestic sewage are practices that can be implemented in the management of sanitary sewage systems. That can be enplaned to improve the management of sewage systems, therefore, expanding the correct destination of wastewater and consequently contribute to the improvement of sanitary sewage index.
5

Remoção de cistos de Giardia spp. e de Cryptosporidium spp. em sistema de tratamento de esgoto sanitário: quantificação em fases líquida e sólida / Removal of Giardia spp. cysts and Cryptosporidium spp. oocists in wastewater treatment systems: quantification in liquid and solid fases

Eraldo Kobayashi dos Santos 25 September 2015 (has links)
No atual cenário de saneamento, há uma escassez de estudos na temática de retenção de microrganismos patogênicos em estações de tratamento de esgotos, onde os principais tratamentos se baseiam na remoção de parâmetros físico-químicos. Uma abordagem mais ampla na remoção destes microrganismos em estações de tratamento e sua quantificação no lodo retido é um passo importante para o aumento do debate acerca da eficiência dos atuais tratamentos utilizados na retenção de patógenos, diminuindo assim a contaminação de corpos d\'água com posteriores problemáticas no âmbito de saúde pública. Desta forma, a proposta do projeto foi avaliar e quantificar a remoção de cistos de Giardia spp., oocistos de Cryptosporidium spp. e Escherichia Coli em sistema de tratamento de esgoto sanitário constituído de tratamento anaeróbio (reator UASB), utilizando dois valores de TDH - 8 horas (Etapa 1) e 12 horas (Etapa 2) - seguido de tratamento em sistema de lodo ativado. O projeto utilizou uma estação de tratamento piloto junto a estação de tratamento da USP São Carlos. Para análises de E. coli e coliformes totais foi utilizada a técnica de pour plate e para detecção de cistos e oocistos de Giardia spp. e Cryptosporidium spp., a técnica de separação imunomagnética (IMS) e técnica de Reação de Imunoflorescência Direta (RID) foi escolhida como método de detecção e quantificação. Para a remoção no reator UASB, a variação de TDH indicou influência na remoção de parâmetros físico-químicos e na retenção de microrganismos, sendo que a utilização de TDH de 12 horas obteve remoções de 0,21 log para cistos Giardia spp. e 0,48 log para oocistos de Cryptosporidium spp. Para o Sistema de Lodo ativado, as remoções foram de 0,48 log e 0,15 para ambos os microrganismos, respectivamente, não havendo influência significativa na retenção com a mudança de TDH do reator UASB. Nas análises em fase sólida, foram observados valores altos de contaminação no lodo, tanto para Giardia spp., quanto para Cryptosporidium spp., onde a viabilidade dos (oo)cistos detectados estiveram na faixa de 30% a 99% nas amostras analisadas. / Currently, the field of sanitation faces a lack of studies on retention of pathogenic microorganisms in wastewater treatment plants, where main treatments are based on the removal of physical and chemical parameters. A broader approach to the removal of pathogens in wastewater treatment systems and their quantification in retained sludge is an important step to increase the debate around the efficiency of prevailing treatments used to retain those microorganisms and to consequently reduce the contamination of water bodies. The present study was conducted to assess and quantify the removal of Giardia spp. cysts, Cryptosporidium spp. oocysts and E. coli in wastewater treatment systems. For the purpose of this research, the treatment consisted of a UASB reactor using two values of hydraulic retention time (HRT) - 8 hours (phase 1) and 12 hours (phase 2) - followed by an activated sludge system. The project was staged in a pilot wastewater treatment plant coupled to USP Sao Carlos\' wastewater treatment system. Pour plate technique was used for analysis of E.coli and total coliforms. IMS was used to detect cysts and oocysts of Giardia spp. and Cryptosporidium spp. DFA (direct immunofluorescence assay) method was chosen to detection and quantification. HRT variation for removal in UASB reactor indicated influence in removal of physical and chemical parameters and in retention of microorganisms. The 12 hours use of HRT obtained removals of 0.21 log for Giardia cysts and 0.48 log for Cryptosporidium oocysts. Activated sludge removals presented 0.48 log and 0.15 log respectively, without significative influence in retention with the HRT\'s change in UASB reactor. High values of contamination were observed during solid-phase analysis in activated sludge, both for Giardia and Cryptosporidium. Here, viability of the (oo)cysts detected was around 30% up to 99% of the analyzed samples.

Page generated in 0.0486 seconds