• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

EFEITO DA TÉCNICA DE APLICAÇÃO DO EDTA COMO PRÉ- CONDICIONAMENTO DA DENTINA ESCLERÓTICA E ESMALTE NA RESISTÊNCIA DE UNIÃO DE ADESIVOS UNIVERSAIS / EDTA application technique effect as preconditioning of sclerotic dentin and enamel on the bond strength of universal adhesives

Martini, Eveline Claudia 03 February 2016 (has links)
Made available in DSpace on 2017-07-24T19:21:57Z (GMT). No. of bitstreams: 1 Eveline Claudia Martini.pdf: 1398008 bytes, checksum: 843a0d30d9ab95c12dc193d9bc916fba (MD5) Previous issue date: 2016-02-03 / The aim of this study was to investigate the effect of different protocols of 17% EDTA (ethylene diamine tetra acetic acid) pre-conditioning on the etching pattern and immediate bond strength of universal adhesives to enamel and sclerotic dentin. Forty bovine teeth with sclerotic dentin and twenty human third molars were randomly divided into eight groups resulting from the combination of the main factors surface treatment (none, 2-min EDTA conditioning manual application; 30-second EDTA manual application; 30-second EDTA sonic application) and adhesive system (Scotchbond Universal Adhesive [SBU] and Prime & Bond Elect [PBE]). Resin-dentin and enamel-dentin bonded specimens were prepared and tested under the microtensile bond strength (μTBS) and microshear bond strength (μSBS) tests respectively. The etching patterns produced on the enamel and on the sclerotic dentin surfaces were evaluated under scanning electron microscope (SEM). Results:None of the EDTA pre-conditioning protocols had any impact on the μSBS on enamel (p > 0.05). In sclerotic dentin, the lowest μTBS was observed in the group without EDTA pre-conditioning and the highest in the 30-second EDTA sonic application group. SBU showed the highest μTBS for all the groups (p < 0.05). EDTA preconditioning improved the etching pattern of enamel and dentin in all groups. EDTA pre-conditioning improved the bonding performance and etching pattern of the universal adhesives used in the self-etch mode on sclerotic dentin, mainly when applied for 30 s with the aid of a sonic device. EDTA pre-treatment also improved the retentive etching pattern on enamel but it did not result in higher enamel bond strength. / O objetivo deste estudo foi investigar o efeito de diferentes protocolos de précondicionamento com ácido etilenodiamino tetra-acético (EDTA) a 17% na resistência de união (RU) e padrão de condicionamento para adesivos universais no modo autocondicionante em esmalte e dentina esclerótica. Quarenta dentes bovinos com dentina esclerótica e vinte terceiros molares humanos foram divididos aleatoriamente em oito grupos resultantes da combinação dos fatores principais tratamento de superfície (controle, aplicação manual de EDTA por 2 min; aplicação manual de EDTA por 30 s; aplicação sônica de EDTA por 30 s) e os sistemas adesivos (Single Bond Universal [SBU] e Prime & Bond Elect [PBE]). Espécimes de resina-dentina e de resina-esmalte foram preparados e testados quanto à RU por microtração e por microcisalhamento, respectivamente. Os dados foram submetidos à análise de variância de dois fatores (adesivo e modo de aplicação) e teste de Tukey (α = 5%). O padrão de condicionamento produzido sobre a superfície de esmalte e de dentina esclerosada foi avaliada qualitativamente em microscópio eletrônico de varredura (MEV). Nenhum dos protocolos de EDTA influenciou a resistência de união ao esmalte (p > 0,05). Na dentina esclerótica, os menores valores de RU foram observados sem tratamento com EDTA e o maior valor foi observado no grupo de aplicação sônica de EDTA por 30 s, tendo os demais grupos desempenho intermediário. Tanto em esmalte como em dentina, o adesivo SBU apresentou maiores valores de RU em todos os grupos (p < 0,05). Um melhor padrão de condicionamento foi observado após tratamento com EDTA em relação ao grupo sem tratamento prévio de EDTA. O pré-condicionamento com EDTA melhorou a RU e o padrão de condicionamento de adesivos universais aplicados no modo autocondicionante sobre a dentina esclerótica, principalmente quando aplicada com dispositivo sônico durante 30 s. Em esmalte, o condicionamento prévio com EDTA melhorou o padrão de condicionamento, porém não resultou em maior RU.
2

Influência do aquecimento de agentes de acoplamento químico na resistência de união de um cimento resinoso à zircônia / Influence of heating of chemical coupling agents on the bond strength of a resin cement to zirconia

Calderon, Marcelo Geovanny Cascante 07 December 2018 (has links)
Esta pesquisa in vitro avaliou a influência do aquecimento de diferentes agentes de acoplamento na resistência de união de um cimento resinoso (Panavia F2.0®/Kuraray Noritake. Japão) e uma zircônia (Y-TZP - YZ ). Inicialmente, placas de zircônia foram silicatizadas com o sistema Rocatec (3M / ESPE). Foram aplicados os agentes de acoplamento químico: Single Bond Universal (3M/ESPE); Monobond N (Ivoclar Vivadent) e Clearfil Ceramic Primer (Kuraray Co); após, foram aquecidos em um forno resistivo em diferentes temperaturas (750C e 1000C) por 5 min, antes da cimentação resinosa de um cilindro de resina composta previamente confeccionado (diam. 0,8 mm). Os grupos controle de cada agente de acoplamento foram mantidos à temperatura ambiente (240C). Metade dos corpos-de-prova foi submetida imediatamente ao teste de microcisalhamento (0,5 mm/min) realizado com auxílio de um fio ortodôntico e a outra metade envelhecida por meio de a 2.000 ciclos térmicos (50C e 550C), seguido de armazenamento em água destilada a 370 C por 2 meses, antes do ensaio mecânico. A análise de variância de três fatores (ANOVA) e o teste de Tukey (p?0,05) mostraram que o aquecimento dos agentes químicos de acoplamento produziu maiores valores de resistência de união entre o cimento e a zircônia. A resistência de união imediata foi superior para o Monobond N (30 MPa) e Single Bond Universal (32,5 MPa). Após o envelhecimento, houve redução da resistência de união em todos os grupos e o grupo Monobond N (16,9 MPa) apresentou resistência de união superior à dos demais. A associação de um tratamento térmico simples a um agente de acoplamento é válida para produzir resistência de união superior entre o cimento resinoso e a zircônia. / This in vitro study evaluated the influence of the heating different coupling agents on microshear bond strength between zirconia (Y-TZP-YZ ) and a resin cement (Panavia F2.0® / Kuraray Noritake, Japan). Initially, the zirconia blocks were silicoated with the Rocatec system (3M / ESPE). After, the chemical coupling agents were applied: Single Bond Universal (3M / ESPE); Monobond N (Ivoclar Vivadent) and Clearfil Ceramic Primer (Kuraray Co). They were then heated in a resistive furnace at different temperatures (750C and 1000C) for 5 min prior to resin cementation of a preformed resin composite cilinder (0.8 mm diameter). Control groups were maintained at room temperature (240C). Half of the specimens were immediately submitted to the microshear test (0.5 mm/min) performed with an orthodontic wire and the other half was subjected to 2,000 thermal cycles (50C and 550C), followed by storage in distilled water at 370C for 2 months before the microshear test. 3-way ANOVA and Tukey\'s test (p<0.05) showed that the heating of the chemical coupling agents produced higher bond strength between the ceramic and resin cement. Immediate bond strength was superior for Monobond N (30 MPa) and Single Bond Universal (32,5 MPa). After aging, there was reduction of bond strength in all groups and the Monobond N group (16,9 MPa) was superior to the others. The combination of a simple heat treatment with a coupling agent is valid to produce greater bond strength.
3

Efeito de três diferentes doses de radiação com raios-X na microdureza, morfologia superficial, espectrometria de energia dispersiva de radios-X (EDS) e resistência de união ao esmalte e dentina com dois diferentes sistemas adesivos / The effect of three different doses of radiation with x-rays in the microhardness, superficial morfology, energy dispersive X-ray spectroscopy (EDS) and bond strength of enamel and dentin with two adhesive systems

Cunha, Sandra Ribeiro de Barros da 19 January 2015 (has links)
Este estudo teve como objetivo analisar dentina e esmalte irradiados com diferentes doses de radiação ionizante com raios-x (20, 40 e 70Gy), através da microdureza, morfologia superficial, conteúdo mineral e resistência de união com adesivo de condicionamento total de 2 etapas (Adper Single Bond 2) e um novo sistema adesivo, universal, com a técnica auto-condicionante (Universal Single Bond). Oitenta e quatro terceiros molares humanos foram cortados, separados e preparados para cada ensaio. Para os ensaios de microdureza e microcisalhamento as amostras foram incluídas em resina acrílica e polidas. Para a microscopia eletrônica de varredura (MEV) e espectrometria de energia dispersiva de raios-x (EDS), as amostras foram fixadas em solução de glutaraldeído 3%, lavadas em solução de cacodilato 0,1M e desidratadas em álcool etílico crescente. A microdureza (n=30) foi realizada pré e pós-radioterapia, com força de 50gf em esmalte cervical, médio e oclusal e 25gf em dentina profunda, média e rasa, por 30s. As amostras para o microcisalhamento foram divididas em 4 grupos (n=20) e 2 subgrupos (n=10) conforme o sistema adesivo. Foram construídos 3 corpos de prova cilíndricos com 1mm de diâmetro e altura em cada amostra. O teste de microcisalhamento foi realizado em máquina de ensaio universal com velocidade de 1mm/min. Os resultados indicam perda de propriedade de microdureza apenas em esmalte cervical em todas as três doses (20Gy pré-radioterapia: 298,04±11,80 e pós-radioterapia: 294,36±16,68; 40Gy pré-radioterapia: 285±19,45 e pósradioterapia: 275,3±36; 70Gy pré-radioterapia: 291,98±16,51 e pós-radioterapia: 283,68 ± 21,64) e em dentina em todas as profundidades (profunda: 20Gy préradioterapia: 57,79±1,96; pós-radioterapia: 55,37±1,30; 40Gy pré-radioterapia: 57,31±1,76; pós-radioterapia: 55,83±1,63; 70Gy não apresentou alterações; média: 20Gy pré-radioterapia: 58,05±1,79; pós-radioterapia: 55,36±1,20; 40Gy préradioterapia: 57,87± 2,04; pós-radioterapia: 55,65 ± 2,48; 70Gy não apresentou alterações; rasa: 20Gy pré-radioterapia: 56,60±12,17; pós-radioterapia: 55,18±2,57; 40Gy pré-radioterapia: 57,36±2,78; pós-radioterapia: 55,18± 2,57; 70Gy préradioterapia: 55,08±1,94; pós-radioterapia: 54,72±2,57). O teste de microcisalhamento não apresentou diferença significativa entre grupo controle e as 3 doses, tanto para esmalte (p=0,325) como para dentina (p=0,719), apresentando o adesivo Universal Single Bond, em dentina, a resistência de união mais satisfatória. A análise de padrão de fratura para dentina, indicou um maior número de rupturas coesivas em dentina na dose 70Gy quando comparada ao grupo controle. Em esmalte prevaleceram as fraturas do tipo adesivas. As eletromicrografias apresentaram alterações apenas em esmalte na dose 70Gy, com prismas de esmalte mais curtos e arredondados. O EDS mostrou que o conteúdo mineral permaneceu intacto em ambos substratos. Dentro das limitações de um estudo in vitro, conclui-se que a radiação ionizante apresenta maior interação preferencialmente em dentina, no entanto, o EDS mostra não haver modificação no conteúdo mineral em ambos substratos. Existe uma diminuição da microdureza em dentina, porém as alterações não são suficientes para interferir na resistência de união dos substratos irradiados, que mostraram resultados mais satisfatórios com o sistemas adesivos universal, utilizando-se a técnica auto-condicionante. / The aim of this study was to evaluate the effects of different doses (20Gy, 40Gy and 70Gy) of ionizing radiation with x-rays in the microhardness, superficial morphology, mineral content and bonding effectiveness with a 2 steps all-etch adhesive (Adper Single Bond 2) and the new generation of adhesive, the universal adhesive system, (Universal Single Bond), using the self-etch technique. Eighty-four third molars were cutted, separed and prepared for each assay. For the microshear-bond and microhardness the samples were included in acrylic resin and then polished. For the scanning electron miscroscopy (SEM) and energy dispersive x-ray spectroscopy (EDS), the samples were fixated in a 3% glutaraldehyde solution, washed in 0,1M cacodylate solution and dehydrated in increscent concentrations of ethyl alcohol. The microhardness (n=30) was held pre and post radiotherapy with 50gf on cervical, middle and occlusal enamel and 25kg on superficial, middle and deep dentin, both cases with 30s. The microshear-bond was divided in 4 groups (n=20) and 2 subgroups (n=10) according to the adhesive system. Three cylinders were built with 1mm in diameter and heigh in every sample. The assay were accomplished at an universal testing machine with 1mm/min. Results indicate loss of microhardness properties only in cervical enamel at all 3 doses (20Gy pre-radiotheraphy: 298,04 ± 11,80 and post-radiotherapy: 294,36 ± 16,68; 40Gy pre-radiotherapy: 285 ± 19,45 and post-radiotherapy: 275,3 ± 36; 70Gy pre-radiotherapy: 291,98 ± 16,51 and post-radiotherapy: 283,68 ± 21,64) and in all dentin depths (deep: 20Gy preradiotherapy: 57,79 ± 1,96; post-radiotherapy: 55,37 ± 1,30; 40Gy pre-radiotherapy: 57,31 ± 1,76; post-radiotherapy: 55,83 ± 1,63; 70Gy showed no alteration; Middle: 20Gy pre-radiotherapy: 58,05 ± 1,79; post-radiotherapy: 55,36 ± 1,20; 40Gy preradiotherapy: 57,87 ± 2,04; post-radiothetrapy: 55,65 ± 2,48; 70Gy showed no alteration; Superficial: 20Gy pre-radioterapia: 56,60 ± 12,17; post-radiotrapia: 55,18 ± 2,57; 40Gy pre-radiotherapy: 57,36 ± 2,78; post-radiotherapy: 55,18 ± 2,57; 70Gy pre-radiotherapy: 55,08 ± 1,94; post-radiotherapy: 54,72 ± 2,57). The microshearbond test did not show significant difference between the control group and the 3 doses, both enamel (p=0.325) and dentin (p=0.719), showing better bonding with Universal Single Bond adhesive in dentin. The fracture pattern analysis indicated a larger number of cohesive failure in dentine with the 70Gy dose when compared with control group. The micrographs showed changes only on enamel at 70Gy dose, with shorter and rounder prisms. EDS test indicated no changes in mineral content for both substrates. Knowing the limitations of an in vitro study, it were concluded that ionizing radiation shows deleterious effects preferentially in dentin, probably due to it\'s high organic content, since EDS showed no modifications both enamel and dentin. There is a reduction in microhardness on dentin, but the changes are not enough to interfere at bonding properties of irradiated substrates, showing better results when used the universal adhesive with the self-etch techniques.
4

Efici?ncia dos adesivos universais e primers na ades?o ? zirc?nia

Lopes, Raquel de Oliveira 17 January 2018 (has links)
Submitted by PPG Odontologia (odontologia-pg@pucrs.br) on 2018-05-28T13:41:25Z No. of bitstreams: 1 RAQUEL_DE_OLIVEIRA_LOPES_TES.pdf: 2230148 bytes, checksum: a749d045cae0f8098669b38fe6b648b6 (MD5) / Approved for entry into archive by Caroline Xavier (caroline.xavier@pucrs.br) on 2018-06-11T18:19:23Z (GMT) No. of bitstreams: 1 RAQUEL_DE_OLIVEIRA_LOPES_TES.pdf: 2230148 bytes, checksum: a749d045cae0f8098669b38fe6b648b6 (MD5) / Made available in DSpace on 2018-06-11T18:25:33Z (GMT). No. of bitstreams: 1 RAQUEL_DE_OLIVEIRA_LOPES_TES.pdf: 2230148 bytes, checksum: a749d045cae0f8098669b38fe6b648b6 (MD5) Previous issue date: 2018-01-17 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior - CAPES / (Artigo Os adesivos universais s?o t?o eficientes quanto um primer para a ades?o ? zirc?nia?) O objetivo do trabalho foi comparar a resist?ncia de uni?o ? cer?mica de zirc?nia de quatro adesivos universais e um primer para zirc?nia. Setenta e cinco amostras de zirc?nia foram confeccionadas e inclu?das em resina acr?lica. A superf?cie das amostras foi polida com lixas de carbeto de sil?cio nas granula??es 600, 800 e 1.200 e jateadas com ?xido de alum?nio 50 ?m por 5 s. As amostras foram divididas aleatoriamente em cinco grupos (n=15): G1 ? Single Bond Universal (SBU); G2 ? All Bond Universal (ABU); G3 ? Peak Universal Bond (PUB); G4 ? Ambar Universal (AU) e G5 ? Z-Prime Plus (ZP). Um cone de resina composta foi constru?do, atrav?s de uma matriz, sobre o material adesivo aplicado na superf?cie das amostras. Os corpos de prova foram armazenados em ?gua destilada a 37?C por 24 h, sendo submetidos ao teste de resist?ncia de uni?o ? tra??o em m?quina de ensaio universal EMIC com velocidade de 0,5 mm/min. Os tipos de falhas foram classificados em adesiva, coesiva ou mista. Os valores de resist?ncia de uni?o foram submetidos ? an?lise de vari?ncia (ANOVA), seguido do teste de Tukey (?=0,05). M?dias de resist?ncia de uni?o (MPa) seguidas de letras distintas diferem estatisticamente entre si: G5=21,12a, G1=20,55a, G4=19,12ab, G2=14,22b, G3=8,45c. As falhas foram predominantemente mistas no G1, G4 e G5, e predominantemente adesivas no G2 e G3. Os adesivos SBU e AU obtiveram resist?ncia de uni?o compar?vel ao ZP. / (Artigo Bond to zirconia ceramic: evaluation of different primers and a universal adhesive) The aim of the study was to evaluate the effect of a universal adhesive and different primers on the bond strength to zirconia ceramic. Seventy-five zirconia ceramic samples were obtained and divided into five groups (n=15): G1 ? Scothbond Universal (SBU); G2 ? silane + SBU; G3 - Signum Zirconia Bond; G4 - Z-Prime Plus; G5 - MZ Primer. A cone of composite resin was built. The specimens were stored in 100% relative humidity with distilled water at 37?C for 48 h, and then submitted to a tensile bond strength test in a universal testing machine at a crosshead speed of 0.5 mm/min. The type of failure that occurred during the debonding procedure was analyzed. The mean results of the bond strength test (MPa) followed by the same letter represent no statistical difference by ANOVA and Tukey?s post-hoc test (p<0.05): G2=27.55a (?6.99), G4=23.71a (?5.65), G1=22.64a (?5.67), G5=13.64b (?5.49), G3=7.54c (?4.75). G2 and G4 exhibited predominantly cohesive failure in the resin composite cone. G1 and G5 had predominantly mixed failures, and G3 exhibited only adhesive failures. The SBU and Z-Prime Plus provided higher bond strength to zirconia ceramic. / (Artigo Os adesivos universais s?o t?o eficientes quanto um primer para a ades?o ? zirc?nia?) The aim of the study was to compare four universal adhesives and a primer on the bond strength to zirconia ceramic. Seventy-five zirconia ceramic samples were obtained and embedded in acrylic resin. The surface of the samples was polished with 600-, 800- and 1200-grit silicon carbide abrasive papers, and sandblasted with 50 ?m aluminum oxide particles for 5 s. The samples were divided into five groups (n=15): Single Bond Universal (SBU); G2 ? All Bond Universal (ABU); G3 ? Peak Universal Bond (PUB); G4 ? Ambar Universal (AU) e G5 ? Z-Prime Plus (ZP). A cone of composite resin was built on the adhesives and primer applied. The specimens were stored in distilled water at 37oC for 24 h, and then submitted to a tensile bond strength test in a universal testing machine at a crosshead speed of 0.5 mm/min. The type of failure that occurred during the debonding procedure was classified as adhesive, cohesive or mixed. The values of bond strength were analyzed by analysis of variance (ANOVA) followed by Tukey?s test (?=0.05). Means of bond strength (MPa) followed by the distinct letters represent statistical difference: G5=21,12a, G1=20,55a, G4=19,12ab, G2=14,22b, G3=8,45c. The failures were predominantly mixed in G1, G4 and G5, and predominantly adhesive in G2 and G3. SBU and AU adhesives obtained bond strength comparable to ZP.
5

Efeito de três diferentes doses de radiação com raios-X na microdureza, morfologia superficial, espectrometria de energia dispersiva de radios-X (EDS) e resistência de união ao esmalte e dentina com dois diferentes sistemas adesivos / The effect of three different doses of radiation with x-rays in the microhardness, superficial morfology, energy dispersive X-ray spectroscopy (EDS) and bond strength of enamel and dentin with two adhesive systems

Sandra Ribeiro de Barros da Cunha 19 January 2015 (has links)
Este estudo teve como objetivo analisar dentina e esmalte irradiados com diferentes doses de radiação ionizante com raios-x (20, 40 e 70Gy), através da microdureza, morfologia superficial, conteúdo mineral e resistência de união com adesivo de condicionamento total de 2 etapas (Adper Single Bond 2) e um novo sistema adesivo, universal, com a técnica auto-condicionante (Universal Single Bond). Oitenta e quatro terceiros molares humanos foram cortados, separados e preparados para cada ensaio. Para os ensaios de microdureza e microcisalhamento as amostras foram incluídas em resina acrílica e polidas. Para a microscopia eletrônica de varredura (MEV) e espectrometria de energia dispersiva de raios-x (EDS), as amostras foram fixadas em solução de glutaraldeído 3%, lavadas em solução de cacodilato 0,1M e desidratadas em álcool etílico crescente. A microdureza (n=30) foi realizada pré e pós-radioterapia, com força de 50gf em esmalte cervical, médio e oclusal e 25gf em dentina profunda, média e rasa, por 30s. As amostras para o microcisalhamento foram divididas em 4 grupos (n=20) e 2 subgrupos (n=10) conforme o sistema adesivo. Foram construídos 3 corpos de prova cilíndricos com 1mm de diâmetro e altura em cada amostra. O teste de microcisalhamento foi realizado em máquina de ensaio universal com velocidade de 1mm/min. Os resultados indicam perda de propriedade de microdureza apenas em esmalte cervical em todas as três doses (20Gy pré-radioterapia: 298,04±11,80 e pós-radioterapia: 294,36±16,68; 40Gy pré-radioterapia: 285±19,45 e pósradioterapia: 275,3±36; 70Gy pré-radioterapia: 291,98±16,51 e pós-radioterapia: 283,68 ± 21,64) e em dentina em todas as profundidades (profunda: 20Gy préradioterapia: 57,79±1,96; pós-radioterapia: 55,37±1,30; 40Gy pré-radioterapia: 57,31±1,76; pós-radioterapia: 55,83±1,63; 70Gy não apresentou alterações; média: 20Gy pré-radioterapia: 58,05±1,79; pós-radioterapia: 55,36±1,20; 40Gy préradioterapia: 57,87± 2,04; pós-radioterapia: 55,65 ± 2,48; 70Gy não apresentou alterações; rasa: 20Gy pré-radioterapia: 56,60±12,17; pós-radioterapia: 55,18±2,57; 40Gy pré-radioterapia: 57,36±2,78; pós-radioterapia: 55,18± 2,57; 70Gy préradioterapia: 55,08±1,94; pós-radioterapia: 54,72±2,57). O teste de microcisalhamento não apresentou diferença significativa entre grupo controle e as 3 doses, tanto para esmalte (p=0,325) como para dentina (p=0,719), apresentando o adesivo Universal Single Bond, em dentina, a resistência de união mais satisfatória. A análise de padrão de fratura para dentina, indicou um maior número de rupturas coesivas em dentina na dose 70Gy quando comparada ao grupo controle. Em esmalte prevaleceram as fraturas do tipo adesivas. As eletromicrografias apresentaram alterações apenas em esmalte na dose 70Gy, com prismas de esmalte mais curtos e arredondados. O EDS mostrou que o conteúdo mineral permaneceu intacto em ambos substratos. Dentro das limitações de um estudo in vitro, conclui-se que a radiação ionizante apresenta maior interação preferencialmente em dentina, no entanto, o EDS mostra não haver modificação no conteúdo mineral em ambos substratos. Existe uma diminuição da microdureza em dentina, porém as alterações não são suficientes para interferir na resistência de união dos substratos irradiados, que mostraram resultados mais satisfatórios com o sistemas adesivos universal, utilizando-se a técnica auto-condicionante. / The aim of this study was to evaluate the effects of different doses (20Gy, 40Gy and 70Gy) of ionizing radiation with x-rays in the microhardness, superficial morphology, mineral content and bonding effectiveness with a 2 steps all-etch adhesive (Adper Single Bond 2) and the new generation of adhesive, the universal adhesive system, (Universal Single Bond), using the self-etch technique. Eighty-four third molars were cutted, separed and prepared for each assay. For the microshear-bond and microhardness the samples were included in acrylic resin and then polished. For the scanning electron miscroscopy (SEM) and energy dispersive x-ray spectroscopy (EDS), the samples were fixated in a 3% glutaraldehyde solution, washed in 0,1M cacodylate solution and dehydrated in increscent concentrations of ethyl alcohol. The microhardness (n=30) was held pre and post radiotherapy with 50gf on cervical, middle and occlusal enamel and 25kg on superficial, middle and deep dentin, both cases with 30s. The microshear-bond was divided in 4 groups (n=20) and 2 subgroups (n=10) according to the adhesive system. Three cylinders were built with 1mm in diameter and heigh in every sample. The assay were accomplished at an universal testing machine with 1mm/min. Results indicate loss of microhardness properties only in cervical enamel at all 3 doses (20Gy pre-radiotheraphy: 298,04 ± 11,80 and post-radiotherapy: 294,36 ± 16,68; 40Gy pre-radiotherapy: 285 ± 19,45 and post-radiotherapy: 275,3 ± 36; 70Gy pre-radiotherapy: 291,98 ± 16,51 and post-radiotherapy: 283,68 ± 21,64) and in all dentin depths (deep: 20Gy preradiotherapy: 57,79 ± 1,96; post-radiotherapy: 55,37 ± 1,30; 40Gy pre-radiotherapy: 57,31 ± 1,76; post-radiotherapy: 55,83 ± 1,63; 70Gy showed no alteration; Middle: 20Gy pre-radiotherapy: 58,05 ± 1,79; post-radiotherapy: 55,36 ± 1,20; 40Gy preradiotherapy: 57,87 ± 2,04; post-radiothetrapy: 55,65 ± 2,48; 70Gy showed no alteration; Superficial: 20Gy pre-radioterapia: 56,60 ± 12,17; post-radiotrapia: 55,18 ± 2,57; 40Gy pre-radiotherapy: 57,36 ± 2,78; post-radiotherapy: 55,18 ± 2,57; 70Gy pre-radiotherapy: 55,08 ± 1,94; post-radiotherapy: 54,72 ± 2,57). The microshearbond test did not show significant difference between the control group and the 3 doses, both enamel (p=0.325) and dentin (p=0.719), showing better bonding with Universal Single Bond adhesive in dentin. The fracture pattern analysis indicated a larger number of cohesive failure in dentine with the 70Gy dose when compared with control group. The micrographs showed changes only on enamel at 70Gy dose, with shorter and rounder prisms. EDS test indicated no changes in mineral content for both substrates. Knowing the limitations of an in vitro study, it were concluded that ionizing radiation shows deleterious effects preferentially in dentin, probably due to it\'s high organic content, since EDS showed no modifications both enamel and dentin. There is a reduction in microhardness on dentin, but the changes are not enough to interfere at bonding properties of irradiated substrates, showing better results when used the universal adhesive with the self-etch techniques.

Page generated in 0.0679 seconds