1

Infiltração marginal em cavidades de classe V. Efeito de sistema adesivo e preparo cavitário /

Araújo, Taylane Soffener Berlanga de. January 2005 (has links)
Orientador: Maria Salete Machado Cândido / Banca: Edson Alves de Campos / Banca: Luís Alberto Plácido Penna / Banca: José Roberto Cury Saad / Banca: Marcelo Ferrarezi de Andrade / Resumo: Este estudo teve por objetivo analisar in vitro a influência de dois sistemas adesivos resinosos, sendo um autocondicionante de dois passos (Clearfil SE Bond 2) e um convencional também de dois passos (Master Bond), bem como o tratamento das margens cavitárias no controle da microinfiltração marginal. Preparos cavitários de classe V foram executados na face vestibular em 80 dentes anteriores bovinos previamente extraídos, divididos em oito grupos (n=10). O grau de infiltração marginal foi avaliado por penetração do agente traçador (Nitrato de Prata (AgNO3) a 50%) nas paredes incisal e cervical por meio de um "Software-Image Tool", no qual se mede o grau de infiltração em micrômetros e, portanto, análise quantitativa, os resultados submetidos à Análise de Variância seguida do teste de Tukey para observação das diferenças, concluindo-se que: a) os sistemas adesivos apresentaram estatisticamente o mesmo comportamento; b) existe diferença estatisticamente significante entre as técnicas de preparos utilizados sendo que os preparos realizados nos Grupo I e Grupo II, bem como nos Grupos VII e VIII, apresentaram comportamento semelhante e os melhores resultados para redução da microinfiltração; c) os preparos do Grupo III e Grupo IV apresentaram maiores índices de microinfiltração marginal, no entanto, semelhantes aos Grupos V e VI; d) a região cervical apresentou maior nível de microinfiltração quando comparada com a região incisal. / Abstract: This study aimed to analyse in vitro the influence of two resinous adhesive systems: one self-etching of two steps (Clearfil SE Bond 2) and one also conventional of two steps (Master Bond), as well as the treatment of the cavity margins in the marginal microleakage control. Cavity preparations of class V were carried out on the buccal surface of 80 bovine anterior teeth, previously extracted, divided into eight groups (n=10). The marginal leakage degree was evaluated by the penetration of the tracer agent (Silver Nitrate (AgNO3) at 50%); on the incisor and cervical walls through a Software-Image Tool that measures the leakage degree in micrometers and, therefore, quantitative analysis, which results were subjected to the Variance Analysis and afterwards to the Tukey's test in order to observe the differences it was possible to conclude that: a) the adhesive systems presented statistically the same behaviour; b) there is a statistically meaningful difference between the preparation techniques that were used and the preparations that were carried out in Group I and Group II, as well as Groups VII and VIII, that presented similar behaviour and the best results for the reduction of microleakage; c) the preparations of Group III and Group IV presented higher rates of marginal microleakage, however, they were similar to Groups V and VI; d) the cervical region presented higher level of microleakage comparing to the incisor region. / Doutor
2

Avaliação da dureza superficial de cimentos resinosos após cimentação de pinos de fibra de vidro : efeito de profundidade de polimerização e sistemas adesivos /

Jardim, Patrícia dos Santos. January 2004 (has links)
Orientador: Maria Salete Machado Cândido / Banca: Adair Stefanello Busatto / Banca: Luiz Alberto Plácido Penna / Banca: Denise Pedrini / Banca: Roberto Cury Saad / Resumo: Os pinos pré-fabricados de fibra de vidro têm sido o sistema de escolha para reconstrução de dentes anteriores tratados endodonticamente e o sucesso da cimentação dos pinos de fibra de vidro está associado à cimentação do tipo adesiva, sendo que o agente cimente normalmente utilizado é um cimento resinoso de dupla polimerização, entretanto questiona-se a eficácia dos cimentos de dupla polimerização, principalmente nas regiões muito distantes da fonte de luz, bem como sua compatibilidade química com sistemas adesivos simplificados. O presente trabalho teve como objetivo avaliar a dureza superficial de cimentos resinosos, um quimicamente ativado (Bistite II DC) e um de dupla polimerização (Rely X) em função de diferentes profundidades de polimerização e sistemas adesivos; bem como, formação de camada híbrida quando da cimentação de pino de fibra de vidro no canal radicular de dentes bovinos. Foram utilizados 40 raízes bovinas, as quais foram tratadas endodonticamente e divididas aleatoriamente em 4 grupos de 10 raízes cada de acordo com o cimento resinoso e sistema adesivo utilizado para cimentação do pino de fibra de fivro: (GI) Bistite II DC; (GII) Rely X associado ao Scotchbond Multi-Uso Plus; (GIII) Rely X associado ao Single Bond; (GIV) Rely X associado ao One-Up Bond F. Após 24 horas da cimentação, as raízes foram seccionadas no sentido transversal em três discos radiculares, representando os terços cervical, médio e radicular, com profundidades respectivas de 3,0mm; 6,0mm e 9,0mm. Para realização das medidas de dureza, cada secção radicular foi dividida em quadrantes, nos quais foram realizadas três medidas: (M1) próximo à dentina radicular; (M2) região intermediária; (M3), próximo ao pino de fibra de vidro, cujos resultados foram submetidos à Análise de Variância e Teste de Tukey. Após o Ensaio de Dureza, as amostras foram... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: Fiber posts have been the system of choice for endodontically-treated anterior teeth reconstruction, and the cementation luting success is associated to adhesive-type cementation, being the dual-cure resin cements the most utilized cement. However, the dual-cured cements efficacy is questioned, mainly in the regions distant from the light-cure source, as well as the chemical compatibility to simplified adhesive systems. The aim of the present study was evaluate superficial roughness of resin cements, being one of them chemically activated (Bistite II DC) and the other dual-cured resin cement (Rely X) under different light-cure depths and bond systems; as well as hybrid layer formation in cases of glass fiber post in bovine radicular canal. Forty bovine roots samples were used. These roots were endodontically treated and randomly separated in four groups of 10 roots each according to the resin cement and adhesive system used for glass fiber post cementation.: The groups were divided as follows: (GI) Bistite II DC; (GII) Rely X associated to Scotchbond Multi-Purpose Plus; (GIII) Rely X associated to Single Bond; (GIV) Rely X associated to One-Up Bond F. After 24 hours passed from cementation, roots were sectioned in transversal orientation in three radicular discs, representing the cervical, medium and radicular thirds, with respective depths of 3,0mm; 6,0mm e 9,0mm. For hardness measuring, each radicular section was divided in quadrants. These quadrants were measured three times: (M1) near radicular dentin; (M2) intermediary region; (M3), near glass fiber post. These results were submitted to ANOVA and Tukey Test. After hardness assay samples were submitted to hybrid layer evaluation in Scanning Electron Microscopy and subsequent photomicrography descriptive analysis. From the methodology and... (Complete abstract, click electronic address below). / Doutor
3

Análise da resistência adesiva à dentina de diferentes sistemas adesivos pelo teste de microtração e microscopia eletrônica de varredura /

Mazur, Rui Fernando. January 2003 (has links)
Orientador: José Roberto Cury Saad / Banca: Marcelo Ferrarezi de Andrade / Banca: Welingtom Dinelli / Banca: Rodrigo Nunes Rached / Banca: Paulo Sérgio Quagliatto / Resumo: O objetivo deste trabalho foi realizar, in vitro, avaliação da resistência de adesiva pelo teste de microtração de dez sistemas adesivos diferentes. Os sistemas adesivos One Up Bond F - Tokuyama, Clearfil SE Bond - Kuraray, Adper Prompt L-Pop, Single Bond - 3M/ESPE, One Step - Bisco, One Step Plus - Bisco, Prime&Bond NT - Dentsply, Excite - Vivadent, Scotchbond Multi - Uso - 3M/ESPE e All Bond 2 - Bisco. Para a realização do teste foram utilizados quarenta dentes molares hígidos, sendo que destes dentes dez foram utilizados para a microscopia eletrônica de varredura. Para a realização do teste de microtração os dentes foram cortados na superfície oclusal com disco diamantado e posteriormente foram desgastados com discos de lixa. Posteriormente as amostras foram restauradas com os respectivos sistemas adesivos e resina composta Z-100 com tempo de polimerização de 40 segundos cada incremento. Após vinte e quatro horas de armazenagem em temperatura de 37ºC os dentes foram seccionados com disco diamantado com finalidade de obter palitos com área de 1,0 +- 0,2 mm2. Após o corte os palitos foram armazenados em temperatura de 37ºC por vinte e quatro horas e em seguida foram levados para a máquina de ensaio universal EMIC 500 DL onde os palitos foram tracionados com velocidade de 1 mm/min. Os resultados foram analisados pelo através dos testes de normalidade de Lilliefors e de homogeneidade de variância de Bartlett. Quando alguns dos pressupostos não se verificaram, utilizou-se o teste não paramétrico de Kruskal - Wallis. Os resultados obtidos foram em ordem decrescente de 36,73 +- 10,52 para o sistema adesivo One Up Bond F, seguido do sistema de três etapas All Bond 2 com 34,29 +- 12,63 para o sistema adesivo One Step Plus foi de 33,18 +- 11,33 para o sistema Adper Prompt L-Pop de 31,76 +- 11,3, sistema One Step de 29,02 +- 11,28, para o... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The aim of this study was to analyze the bond strength of ten adhesive systems: One Up Bond F - Tokuyama (OU); Adper Prompt L-Pop - 3M-ESPE (AP); Clearfil SE Bond - Kuraray CO. (SE); Prime Bond NT - Caulk-Dentsply (NT); Single Bond - 3M-ESPE (SB); One Step - Bisco (OS); One Step Plus - Bisco (OP); Excite - Vivadent (EX); Scotchbond Multi - Purpose (SMP) e All Bond 2 - Bisco (AB). Methods: Forty freshly extracted human teeth were transversely wetcut using a diamond disk in order to expose the occlusal dentin surface. Then the adhesive systems were applied according to the manufacturer's instruction. The teeth were restored with composite resin Z-100 (3M) and stored in distilled water at 37ºC for 24 hours. A slow-speed diamond disk was used to prepare microtensile test specimens, with a bonded area of 1,00 +- 0,2 mm2. Each group was composed of thirty sticks, which were stored in distilled water at 37ºC for 24 hours. The sticks were bonded on a universal testing machine at a cross head speed of 1 mm/min. The following results demonstrate values microtensile bond strengths in MPa. Data were statistically analyzed by Kruskal-Wallis Test (p<-0.05). The bond strength values were 36,73 +- 10,52 for One Up Bond F, 34,29 +- 12,63 for All Bond 2, 33,18 +- 11,33 for One Step Plus, 31,76 +- 11,3 for Adper Prompt L-Pop, 29,02 +- 11,28 for One Step, 28,82 +- 14,74 for Single Bond, 28,08 +- 12,09 for Clearfil SE Bond, 26,31 +- 9,02 for Scotchbond Multi - Purpose, 21,35 +- 10,22 for Prime&Bond NT and 19,52 +- 10,08 for Excite. Ten teeth were analysed by SEM and all of them showed resin into the dentin tubules. Most of fractures were adhesive in the composite/teeth interface. One up bond F (OU) resulted in higher bond strength when compared to all the other systems tested and Excite resulted in lower bond strength. Self-etching systems were not statistically... (Complete abstract, click electronic address below). / Doutor
4

Análise da microestrutura do amálgama dental quando associado a diferentes materiais intermediários /

Jardim, Patrícia dos Santos. January 2002 (has links)
Orientador: Maria Salete Machado Cândido / Banca: Osmir Batista de Oliveira Júnior / Banca: Denise Pedrini / Resumo: O objetivo deste trabalho foi avaliar através de Análise Metalográfica em Microscopia Eletrônica de Varredura, a ocorrência de possíveis alterações na microestrutura do amálgama, e analisar, através de fotomicrografias, a presença de fendas na interface dente/restauração, quando este é associado a três diferentes materiais adesivos intermediários, sendo eles: Panávia F, Vidrion F e Scotchbond Multi-Uso Plus (SBMP). Para este estudo, foram utilizados 20 terceiros molares recentemente extraídos, os quais receberam preparos Classe I, assim restaurados: GRUPO I (controle): restaurações com amálgama sem a presença de agente intermediário, GRUPO II: restaurações com amálgama associadas ao Panávia F; GRUPO III: restaurações com amálgama associadas ao Vidrion F; e, GRUPO IV: restaurações com amálgama associadas ao SBMP. Após confecção das restaurações, de acordo com as instruções dos fabricantes, os corpos-de-prova permaneceram em água destilada a 370C +/- por 24h e foram submetidos a termociclagem (8oC a 550C). Em seguida, os corpos-de-prova foram seccionados longitudinalmente no sentido mésio-distal e submetidos à análise Metalográfica em Microscopia Eletrônica de Varredura e à análise da interface adesiva através da mensuração da fenda em três regiões distintas: (IA1) interface esmalte/restauração; (IA2) interface ângulo/restauração; (IA3) interface parede pulpar/restauração. Os resultados foram submetidos à análise descritiva e estatística, pela análise de variância, com p=0,05, cujos resultados nos permitiram concluir que: a) Nenhum dos materiais intermediários testados determinou alterações na microestrutura do amálgama; b) Houve aumento significativo na presença de porosidades no interior do amálgama nos Grupos II e III; c) A associação do amálgama aos materiais intermediários não foi... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The aim of the present study was evaluate utilizing Metalographic Analysis in Scanning Electronic Microscopy the occurrence of possible alterations in amalgam microstructure and evaluate, by means of photomicrographies, the presence of gaps in tooth/restoration interface, when associated to three different intermediate adhesive materials, that was: Panavia F, Vidrion F and Scotchbond Multi Purpose Plus (SBMP). For this study, twenty recently extracted third molars were used, and a Class I cavity was made in each tooth and filled in the following form: Group I (control): amalgam restorations without intermediate agent, Group II: amalgam restoration associated with Panavia F, Group III: amalgam restorations associated with Vidrion F, Group IV: amalgam restorations associated with SBMP. After the fillins was made accordingly with the manufacturer's instruction, the test bodies stood in distilled water at 37º C +/- for 24 hours, then being submitted to thermocycling (8º C to 55ºC). Then the test bodies was longitudinally cutted in the medial-distal way, and submitted to the Metalographic Analysis in Scanning Electronic Microscopy and to the adhesive interface analysis through the gap mensuration in three distinct regions: (IA1) tooth/restoration interface; (IA2) angle/restoration interface; (IA3) pulpar wall/restoration interface. The results were submitted to the descriptive and statistical analysis, by the analysis of variance (ANOVA) (p=0,05), which results allowed the following conclusions: a) none of the tested intermediate materials determined amalgam microstructure alterations; b) there was significant increase in porosities in the interior of amalgam of the groups II and III; c) The association of amalgam with intermediate materials was not capable to avoid the gap formation in the tooth/restoration interface... (Complete abstract, click electronic address below). / Mestre
5

Difusão transdentinária e citotoxicidade de sistemas adesivos autocondicionantes /

Lanza, Célia Regina Moreira. January 2007 (has links)
Orientador: Josemeri Hebling / Banca: Roberval de Almeida Cruz / Banca: José Carlos Pereira / Banca: Elisa Maria Aparecida Giro / Banca: Carlos Alberto dos Santos Cruz / Resumo: Este estudo avaliou a difusão transdentinária e a toxicidade de sistemas adesivos autocondicionantes de diferentes valores de pH sobre células odontoblastóides MDPC-23. Sessenta discos de dentina (0,4 mm de espessura) foram obtidos de terceiros molares humanos hígidos e divididos em 6 grupos após a mensuração de sua condutância hidráulica pelo Flodec. Os discos foram montados em câmaras pulpares in vitro, onde 30.000 células foram plantadas no seu lado pulpar (área dentina exposta 0,28 cm2) e mantidas em cultura por 48 h. Após este período, os sistemas adesivos Clearfil SE Bond, Clearfil Protect Bond, Adper Prompt e Xeno III foram aplicados no lado oclusal dos discos. O sistema adesivo Single Bond foi usado como controle positivo e a solução tampão fosfato como controle negativo. A citotoxicidade foi avaliada após 24 horas pelo teste MTT e a morfologia celular por MEV. A difusão transdentinária foi qualificada por CG/EM. Os valores de MTT para os sistemas autocondicionantes, analisados pelos testes de Kruskall-Wallis e Mann-Whitney, foram estatisticamente diferentes do grupo controle negativo. Houve redução da viabilidade celular de 47,8%; 46,5%; 42,1% e 28,0% para o Clearfil SE Bond, Xeno III, Clearfil Protect Bond e Adper Prompt L-Pop, respectivamente. A redução da viabilidade celular foi inferior ao Single Bond (53,1%) para todos os sistemas. A análise por CG/MS identificou o HEMA como principal componente químico difundido pela dentina. Foi possível concluir que todos os sistemas adesivos autocondicionantes avaliados apresentaram difusão transdentinária resultando em redução do metabolismo celular, a qual não foi relacionada a sua capacidade de dissolução da smear layer e desmineralização da dentina subjancente. / Abstract: This study evaluated the transdentinal diffusion and cytotoxicity of self-etching adhesive systems with different pH on the odontoblast cell line MDPC-23. Sixty dentin disks were cut from the crowns of extracted human permanent molar teeth with 0.4 mm thickness and were divided into 6 groups of similar hydraulic conductance (Flodec). The dentin disks were placed in an in vitro pulp chamber and 30.000 cells were planted on their pulpal side (area of exposed dentin 0.28 cm2). After 48 hours, the adhesive systems Clearfil SE Bond, Clearfil Protect Bond, Adper Prompt or Xeno III were applied on the occlusal side and light-cured for 10s. Single Bond was used as positive and phosphate buffer solution (PBS) as negative control group. The cytotoxicity was measured by MTT assay and cell characteristics were assessed by SEM, after 24 h. The transdentinal diffusion was qualified by GC/MS. Kruskall-Wallis and Mann-Whitney tests demonstrated a significant difference among the adhesives and PBS (p<0.05). The cellular viability reduction promoted by the self-etching systems was lower than that of Single Bond (53,1%). Cell metabolism was reduced in 47,8%; 46,5%; 42,1% and 28,0% for Clearfil SE Bond, Xeno III, Clearfil Protect Bond and Adper Prompt, respectively. HEMA was identified as the main diffused component. It was concluded that all investigated self-etching adhesives demonstrated transdentinal diffusion resulting in reduction of the cellular metabolism, which was not related to their capacity to dissolve the smear layer and demineralize the underlying dentin. / Doutor