• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 5
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Electrodeposition of aluminum from alkyl benzene electrolytes.

Capuano, Guido Armando. January 1973 (has links)
No description available.
2

Electrodeposition of aluminum from alkyl benzene electrolytes.

Capuano, Guido Armando. January 1973 (has links)
No description available.
3

Fate and transport of the surfactant linear alkylbenzenesulfonate in a sewage-contaminated aquifer

Krueger, Carolyn J. 05 December 1997 (has links)
Linear alkylbenzenesulfonate (LAS) is the most widely used anionic surfactant in commercial detergent formulations. The environmental fate of LAS is of interest because of its disposal to wastewater treatment facilities and subsequent occurrence as a micropollutant in surface waters and groundwater. While LAS fate in wastewater treatment systems and surface waters is well-documented, few studies describe LAS fate in groundwater. This work investigates the transport and biodegradation of LAS in sewage-contaminated groundwater using natural-gradient pulsed and continuous field tracer tests and laboratory column experiments. An "in-vial" disk elution technique that couples solid phase extraction disk elution of LAS as tetrabutylammonium ion pairs with injection-port derivatization was developed for the determination of LAS in groundwater. Pulsed tracer tests then were conducted in an aerobic (~9 mg/L dissolved oxygen) uncontaminated zone, and a moderately aerobic (~1 mg/L dissolved oxygen), sewage-contaminated zone. A continuous injection test also was conducted in the sewage-contaminated zone. Chromatographic separation of the surfactant mixture was observed and attributed to the greater retardation of the longer alkyl chain homologs during transport. In the sewage-contaminated groundwater, biodegradation preferentially removed the longer alkyl chain homologs and external isomers resulting in LAS mixtures that were enriched in the more mobile and biologically-resistant components. LAS mass removal coincided with a decrease in dissolved oxygen concentrations, the appearance of LAS metabolites, and an increase in the number of free-living bacteria. The composition of the LAS mixture changed in the continuous field and column experiments and biodegradation rates increased as dissolved oxygen concentration increased. Mass removal rates were generally 2-3 times greater in the column experiments than in the field for similar dissolved oxygen concentrations. Rate constants for the continuous and pulsed tests conducted in the field were comparable indicating that increased exposure time of the aquifer sediments to the LAS did not increase biodegradation rates. / Graduation date: 1998
4

Pulsformdiskrimination und Lichtausbeutemessungen von LAB-basierten Flüssigszintillatoren

Kögler, Toni 19 April 2017 (has links) (PDF)
Die Grundlage vieler zukünftiger Flüssigszintillator-Neutrinoexperimente (SNO+, Daya Bay, LENA) ist das Lösungsmittel Lineare-Alkyl-Benzene (LAB, C6H5CnH2n+1, n = 10 - 13). Zusammen mit dem weit verbreiteten Szintillator 2,5-Diphenyloxazole (PPO) ist es ein farb- und geruchsloses Detektormaterial mit hohem Flammpunkt. Im Vergleich zu toluol- oder xylolbasierten Szintillatoren ist LAB+PPO preiswert und nicht gesundheitsschädlich. Die Eigenschaften von LAB machen es ebenfalls interessant für die Anwendung an nELBE, die Neutronenfugzeitanlage im Helmholtz-Zentrum Dresden - Rossendorf. Ein neuer Ansatz zur Bestimmung der Lichtausbeute im niederenergetischen Bereich (bis 2 MeV) wird vorgestellt. Kombiniert wurden Messungen mit (quasi) monoenergetischen Gammastrahlungs-Prüfstrahlern und einem in dieser Arbeit aufgebauten Compton-Spektrometer. Letzteres ermöglicht die Bestimmung der Lichtausbeute bis zu 5 keVee. Der Birks-Parameter wurde für eine Lösung von LAB + 3 g/l PPO sowie für den Flüssigszintillator NE-213 bestimmt. Die relative Lichtausbeute in Bezug auf letzteren konnte mit diesen Messmethoden ebenfalls ermittelt werden. Zur spektralen Analyse des Lumineszenzlichtes wurden Messungen an Fluoreszenz- und UV/VIS- Spektrometern durchgeführt. Die Pulsformdiskriminationsfähigkeit auf LAB basierenden Szintillatoren wurde während eines Flugzeitexperiments in einem gemischten n-gamma-Feld eines Cf(252)-Prüfstrahlers ermittelt. Dabei kamen unterschiedliche Algorithmen der semi-analogen und digitalen Pulsformdiskrimination zum Einsatz. / Linear alkyl benzene (LAB, C6H5CnH2n+1, n = 10 - 13) is the proposed solvent for the SNO+, the Daya Bay Neutrino and LENA experiment. In solution with the commonly used scintillator PPO it is a colourless, odourless and cheap liquid scintillator with a high fash point and low health hazard compared to toluene based ones. The properties of LAB make this scintillator interesting also for nELBE, the neutron time-of-fight facility at Helmholtz-Zentrum Dresden - Rossendorf. A new approach to measure the light yield in the low-energy range using a combination of quasi-monoenergetic photon sources and a Compton-spectrometer is described. The latter allows the measurement of the light yield down to 5 keVee (electron equivalent). The Birks- Parameter was determined for a homemade solution (LAB + 3 g/l PPO) and for NE-213. The light yield (relative to this standard scintillator) was confrmed by measurements using a fuorescence spectrometer. The ability of pulse-shape-discrimination in a mixed n-gamma- field of a Cf(252) source was tested using different digital and semi-analogue techniques.
5

Pulsformdiskrimination und Lichtausbeutemessungen von LAB-basierten Flüssigszintillatoren

Kögler, Toni 28 February 2011 (has links)
Die Grundlage vieler zukünftiger Flüssigszintillator-Neutrinoexperimente (SNO+, Daya Bay, LENA) ist das Lösungsmittel Lineare-Alkyl-Benzene (LAB, C6H5CnH2n+1, n = 10 - 13). Zusammen mit dem weit verbreiteten Szintillator 2,5-Diphenyloxazole (PPO) ist es ein farb- und geruchsloses Detektormaterial mit hohem Flammpunkt. Im Vergleich zu toluol- oder xylolbasierten Szintillatoren ist LAB+PPO preiswert und nicht gesundheitsschädlich. Die Eigenschaften von LAB machen es ebenfalls interessant für die Anwendung an nELBE, die Neutronenfugzeitanlage im Helmholtz-Zentrum Dresden - Rossendorf. Ein neuer Ansatz zur Bestimmung der Lichtausbeute im niederenergetischen Bereich (bis 2 MeV) wird vorgestellt. Kombiniert wurden Messungen mit (quasi) monoenergetischen Gammastrahlungs-Prüfstrahlern und einem in dieser Arbeit aufgebauten Compton-Spektrometer. Letzteres ermöglicht die Bestimmung der Lichtausbeute bis zu 5 keVee. Der Birks-Parameter wurde für eine Lösung von LAB + 3 g/l PPO sowie für den Flüssigszintillator NE-213 bestimmt. Die relative Lichtausbeute in Bezug auf letzteren konnte mit diesen Messmethoden ebenfalls ermittelt werden. Zur spektralen Analyse des Lumineszenzlichtes wurden Messungen an Fluoreszenz- und UV/VIS- Spektrometern durchgeführt. Die Pulsformdiskriminationsfähigkeit auf LAB basierenden Szintillatoren wurde während eines Flugzeitexperiments in einem gemischten n-gamma-Feld eines Cf(252)-Prüfstrahlers ermittelt. Dabei kamen unterschiedliche Algorithmen der semi-analogen und digitalen Pulsformdiskrimination zum Einsatz. / Linear alkyl benzene (LAB, C6H5CnH2n+1, n = 10 - 13) is the proposed solvent for the SNO+, the Daya Bay Neutrino and LENA experiment. In solution with the commonly used scintillator PPO it is a colourless, odourless and cheap liquid scintillator with a high fash point and low health hazard compared to toluene based ones. The properties of LAB make this scintillator interesting also for nELBE, the neutron time-of-fight facility at Helmholtz-Zentrum Dresden - Rossendorf. A new approach to measure the light yield in the low-energy range using a combination of quasi-monoenergetic photon sources and a Compton-spectrometer is described. The latter allows the measurement of the light yield down to 5 keVee (electron equivalent). The Birks- Parameter was determined for a homemade solution (LAB + 3 g/l PPO) and for NE-213. The light yield (relative to this standard scintillator) was confrmed by measurements using a fuorescence spectrometer. The ability of pulse-shape-discrimination in a mixed n-gamma- field of a Cf(252) source was tested using different digital and semi-analogue techniques.

Page generated in 0.0444 seconds