• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 32
  • Tagged with
  • 32
  • 32
  • 32
  • 28
  • 28
  • 27
  • 22
  • 16
  • 14
  • 13
  • 11
  • 10
  • 10
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Influência da orientação proximodistal do mini-implante ortodôntico, na distribuição de tensões: análise numérica / Influence of the mesio-distal direction of the miniscrew on stress distribution: numerical analysis

Cruz, Fernando Luiz Goulart 06 March 2012 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-07-04T21:05:03Z No. of bitstreams: 1 fernandoluizgoulartcruz.pdf: 3319031 bytes, checksum: b8ba4abba29514e3926b4197c93cdcf2 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-13T16:23:44Z (GMT) No. of bitstreams: 1 fernandoluizgoulartcruz.pdf: 3319031 bytes, checksum: b8ba4abba29514e3926b4197c93cdcf2 (MD5) / Made available in DSpace on 2016-07-13T16:23:45Z (GMT). No. of bitstreams: 1 fernandoluizgoulartcruz.pdf: 3319031 bytes, checksum: b8ba4abba29514e3926b4197c93cdcf2 (MD5) Previous issue date: 2012-03-06 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste estudo foi avaliar pelo método de elementos finitos (MEF), a influência da orientação do Mini-implante Ortodôntico (MIO), em relação ao carregamento, na distribuição de tensões no tecido ósseo. Por meio da interface gráfica do programa de elementos finitos Abaqus/CAE, foram confeccionados modelos tridimensionais, correspondentes a um MIO, a uma seção do osso maxilar e dentes pré-molar e molar provenientes de cortes de tomografia computadorizada no formato Dicom. Todas as partes foram consideradas como seções sólidas e homogêneas, com propriedades isotrópicas e lineares-elásticas. Foi aplicada no MIO uma força de 2N, decomposta a 45º em duas componentes sobre o plano normal ao seu eixo longitudinal. Para a simulação numérica, o MIO foi instalado em nove orientações proximodistais diferentes. Uma instalação ortogonal à superfície vestibular (angulação de 0º), outras de -10º, -20º, -30º e -40º a favor da força aplicada e 10º, 20º, 30º e 40º contrários à força aplicada. Por meio do critério de von Mises e da análise das tensões principais observou-se que houve uma variação das tensões em função da orientação, sendo que a situação que ocorreu menor concentração para o osso cortical foi a de 0º, enquanto que a -20º e 20º ocorreram maiores concentrações. Conclui-se que houve influência da orientação proximodistal do MIO, em relação ao carregamento, na distribuição de tensões no tecido ósseo. / The aim of this study was to evaluate, by finite element method (FEM), the influence of load direction on stress distribution in bone tissue around orthodontic miniscrew. By means of the graphic interface of Abaqus/CAE finite element program, tridimensional models were made, corresponding to a miniscrew, section of maxillary bone, premolar and molar teeth taken from computerized tomograph cuts in Dicom format. All parts were considered solid and homogeneous sections with isotropic and linear-elastic properties. A 2N force was applied on the miniscrew, decomposed in two components at 45º on the plane normal to its longitudinal axis. For numerical simulation, the miniscrew was placed in nine different mesio-distal directions. A placement orthogonal to the vestibular surface (angulation of 0º), others of -10º, -20º, -30º and -40º in favor of the force applied and 10º, 20º, 30º and 40º contrary to the force applied. By means of von Mises criteria and analysis of main stressed it was observed that there was a variation in stresses as a result of direction, and the most attenuating situation for the cortical bone was that of 0º, whereas at -20º and 20º higher stress concentrations occurred. It was concluded that there was influence of the mesio-distal direction of the miniscrew in relation to load, of stress distribution in bone tissue.
32

Avaliação da distribuição de tensões em diferentes topografias residuais de molares restaurados com “Endocrown” / Analysis of the stress distribution in different residual topographic of a molar tooth restored with endocrowns

Pérez, Miguel Angel Muñoz 25 February 2010 (has links)
Made available in DSpace on 2017-07-24T19:22:12Z (GMT). No. of bitstreams: 1 Miguel Munoz Perez.pdf: 2838722 bytes, checksum: 47bde0e445ce247501fdda653ceefbb2 (MD5) Previous issue date: 2010-02-25 / The aim of this study was to evaluate with the finite element method (MEF), the stress distribution under simulated functional loading in different cavity preparations using the pulp chamber of an endodontically-treated second mandible left molar to observe the stability and retention of the Endocrown. Computer tomography data of the tooth was obtained to generate a 3D volumetric model. In this 3D digital tooth, different cavity preparations without (Wo) and with (W) cusp coverage were modeled and edited, as well as a restoration and luting layer. All cavity preparations with cusp coverage had a mesio-occlusal-distal extension. To obtain the Poisson ratio and the elastic modulus of the restorative material used in the MEF, ceramic specimens were subjected to flexural tests. The following groups were obtained according to the cavity preparation: intact tooth (control) [IT]; occlusal-distal extension [WoOD], mesioocclusal- distal extension [WoMOD]; with buccal cusp coverage [WB], with lingual cusps coverage [WL]; with coverage of all cusps [WT]; and remnant of 2 mm above of the cement-enamel junction [Rm]. All groups were subjected to a 200 N loading in the Ansys Workbench v12 software and the stress distribution was analyzed by Rankine principal stresses criteria. "None" experimental group simulated stress distribution as the "IT". "WoOD" showed lowest stress levels at the internal angles. Stress levels were higher at internal angles for "W" and "WoMOD". No difference was observed between the other groups when compared to "Wo" and "W" with "MOD" extension. Within the limits of this in vitro study, it was concluded that the presence of a proximal wall was an important biomechanical factor for the remaining dental tissue and that the cusps coverage did not show any advantages for the stress distribution when compared to the more conservative cavity preparations. / O objetivo deste trabalho foi analisar pelo método de elementos finitos (MEF) a distribuição de tensões em diferentes preparos cavitários que utilizaram a câmara pulpar disponível de um dente molar desvitalizado para a estabilidade e retenção de restauração “Endocrown”, submetida à simulação de forças oclusais funcionais. A tomografia computadorizada de uma mandíbula foi digitalmente reconstruída resultando num modelo 3D. Deste modelo foi extraída apenas a parte correspondente ao dente 37. Neste dente digital 3D, diferentes preparos cavitários sem e com envolvimento das cúspides foram modelados e editados, bem como uma restauração e camada de cimento. Todos os modelos com envolvimento das cúspides tiveram uma extensão mesio-ocluso-distal (MOD). Para a obtenção do coeficiente de Poisson e módulo de elasticidade do material restaurador utilizados no MEF, uma cerâmica foi submetida a teste de resistência à flexão. Foram obtidos os seguintes grupos: DH, dente hígido (controle); dois grupos sem envolvimento das cúspides, SeOD (extensão ocluso-distal) e SeMOD (extensão mésio-ocluso-distal); três grupos com envolvimento das cúspides, CeV (envolvimento das cúspides vestibulares), CeL (envolvimento das cúspides linguais) e CeT (envolvimento de todas as cúspides); e RM, remanescente de 2 mm acima do limite esmalte–cimento (LEC). Todos os grupos foram submetidos à simulação de uma carga de 200 N, no software Ansys Workbench v12, avaliando a distribuição de tensões principais de Rankine geradas nos preparos. As simulações demonstraram que os melhores resultados foram obtidos no grupo SeOD. Os resultados dos outros grupos apresentaram leve diferença, sendo muito próximos os resultados obtidos entre preparos cavitários sem e com envolvimento de cúspides, de extensão MOD. Com base nos resultados obtidos, pôde-se concluir que a presença de uma parede proximal é importante fator para beneficiar a biomecânica do remanescente dental, e que o envolvimento cuspídeo não forneceu um melhor prognóstico da situação quando comparando a preparos cavitários mais conservadores.

Page generated in 0.0879 seconds