• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 32
  • Tagged with
  • 32
  • 32
  • 32
  • 28
  • 28
  • 27
  • 22
  • 16
  • 14
  • 13
  • 11
  • 10
  • 10
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Análise das tensões nos primeiros pré-molares superior e inferior, em contato, através do método de elementos finitos / Enamel stress distribution in superior and inferior premolars, in contact, through a finit elements study

Alexandre Carvalho Teixeira 22 February 2006 (has links)
As lesões cervicais não cariosas foram, durante muito tempo, atribuídas à abrasão causada pela escovação dental, e/ou por processos erosivos. Teorias biomecânicas consideram a possibilidade de que concentrações de tensões na região cervical, causadas pela flexão de cúspides, poderiam contribuir, associadas a outros fatores clínicos, para o desenvolvimento dessas lesões chamadas de abfração O presente trabalho pretende através do método de elementos finitos, utilizando o programa ANSYS versão 8.1, analisar a distribuição de tensões na região cervical de modelos bidimensionais parametrizados dos primeiros prémolares superior e inferior quando estes são colocados em contatos cêntrico e excêntricos no plano frontal, sob uma carga de 1 N. Para simulação da diminuição da mobilidade do ligamento periodontal sob cargas de impacto, o valor real do seu módulo de elasticidade foi aumentado para o correspondente ao do osso esponjoso e ao do osso cortical. Os resultados permitiram concluir que, de uma maneira geral, nas posições excêntricas, os dentes se flexionam e tensões de tração ocorrem na região cervical oposta ao contato com valores compatíveis para formação das lesões. Na posição cêntrica, as tensões de tração se manifestam mais na região da fossa central de ambos os dentes e na cervical do pré-molar inferior. A simulação da diminuição da mobilidade dentaria sob cargas de impacto reduziu o valor das tensões de tração, em todas as regiões analisadas, na ordem de 33% para o pré-molar superior e 66% para o inferior, mas não alterou seu padrão de distribuição. / Non carious cervical lesions were often attributed to toothbrush abrasion and/or erosive process. Biomechanical theories consider that stress concentration in the cervical area, caused by cuspal flexure, may contribue, associated to other clinical factors for the development of the lesion called abfraction. The aim of this finite element study, using the ANSYS version 8.1, is to analyze the stress distribution in the cervical region of superior and inferior premolars bidimensional models. Contacts in centric and eccentric positions were reproduced under a 1 N load. To simulate tooth mobility reduction under impact loads, the elastic modulus of the periodontal ligament was increased to reach the corresponding ones of the alveolar and cortical bone. The results showed that, in eccentric positions, teeth bend and tensile stress are generated at the cervical region opposed to the contact side, justifying the possibility to initiation of the lesion. In centric position, tensile stress occurred on both teeth at the central fossae and at the buccal cervical area of the inferior premolar. The simulation of tooth mobility reduction under impact loads diminished the tensile stress value, at all of the analyzed positions, in a rate of 33% and 66% respectively to superior and inferior premolars.
12

Avaliação de núcleo metálico fundido, núcleo com fibra de vidro e endocrown em cerâmica: análise comparativa pelo método dos elementos finitos

Rossato, Desirée Mory [UNESP] 23 March 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-03-23Bitstream added on 2014-06-13T19:20:24Z : No. of bitstreams: 1 rossato_dm_dr_arafo.pdf: 3020954 bytes, checksum: 1a5b7cd1dca8b24d2c32a870ea1c52b3 (MD5) / Dentes tratados endodonticamente têm uma maior incidência a fraturas, tornando sua restauração um desafio para a Odontologia. Foram selecionados três incisivos centrais superiores humanos os quais foram restaurados com núcleo metálico fundido e coroa de cerâmica IPS emax®Press, núcleo de preenchimento em resina ccomposta associado ao pino de fibra de vidro e coroa de cerâmica IPS emax®Press e endocrown em cerâmica IPS emax®Press. Os dentes foram levados ao teste estático de fratura. Paralelamente foi realizado um modelo virtual de um incisivo central que apresentava características e restaurações representativas dos dentes que foram levados ao teste de fratura. A análise computacional pelo método dos elementos finitos 3D foi realizada. Os resultados obtidos nos dois tipos de análise realizada mostram que a coroa endocrown e o pino de fibra de vidro apresentaram um padrão de fratura que não afetou a estrutura radicular enquanto que o núcleo metálico fundido apresentou um padrão de fratura desfavorável envolvendo a estrutura radicular condenando o dente. Na análise dos elementos finitos obtivemos uma correta previsibilidade de onde as coroas e núcleos poderiam falhar. A análise dos elementos finitos é uma metodologia importante na análise de novas técnicas e novos materiais. / Restoration of endodontically treated teeth is a common problem in restorative dentistry, related to the fractures occurring in such teeth. Three human maxillary central incisor were selected and restaured with metal core and IPS emax®ceramic crown, glass fiber post with composite core and IPS emax®ceramic crown and IPS emax®ceramic endocrown. Static loading test were performed on each specimen until failure. Paralleled a 3D model of a maxillary central incisor is presented. The same characteristics of the real teeth used in the mechanical test were applied. A 3D finite elements analysis was made. The results of both analysis shows that endocrown and fiber post have a pattern of fracture that not involve the root while metal core presents a catastrophic pattern of fracture in the root. The FEM analysis is an important methodology in the development of new materials.
13

Influência da altura da coroa em implantes osseointegrados: estudo pelo método dos elementos finitos tridimensionais

Moraes, Sandra Lúcia Dantas de [UNESP] 25 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-25Bitstream added on 2014-06-13T18:46:01Z : No. of bitstreams: 1 moraes_sld_dr_araca.pdf: 1714349 bytes, checksum: d5ff02883440cb484b8e2bd8528c5f78 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os implantes dentais têm sido usados extensivamente para a reabilitação de edentulismo total e parcial, com próteses fixas ou removíveis. Em detrimento das suas taxas de sucesso e previsibilidade, falhas ocorrem e são associadas a complicações biomecânicas. Entre os fatores biomecânicos podemos destacar uma proporção adequada entre comprimento do implante e superestrutura. Porém, pouco é encontrado sobre a influência da altura da coroa, o alcance do braço de alavanca e, conseqüentemente, a tensão no osso cortical e no osso trabecular. Apesar do aumento no uso de implantes, muito pacientes que necessitam dessa terapia ficam limitados devido à pouca altura óssea. Sistemas disponibilizam no mercado implantes curtos, onde procedimentos cirúrgicos invasivos poderiam ser evitados; nesses implantes, porém, é muito comum uma relação coroa/área implantada invertida. Desenvolveremos este trabalho em dois capítulos. O primeiro irá avaliar a influência de três alturas de coroas pré-estabelecidas, quando associadas a implantes de hexágono externo em todas as suas estruturas associadas. No segundo, avaliaremos a influência das mesmas alturas de coroas, associadas a implantes de hexágono externo e cone - morse, na distribuição das tensões no tecido ósseo. Para a primeira parte do trabalho, foram confeccionados três modelos tridimensionais, com auxilio dos programas de modelagem gráfica SolidWorks 2006 e Rhinoceros 4.0, além do programa InVesalius (CTI, São Paulo, Brasil), utilizado para gerar o modelo ósseo a partir de uma tomografia computadorizada. Cada modelo foi composto por um bloco ósseo, com um implante de 3,75 x 10,00mm (Conexão Sistemas de Prótese, São Paulo), com o tipo de conexão: hexágono externo, utilizando três alturas de coroas (10 mm; 12.5 mm e 15 mm), colocadas na plataforma oclusal (hexágono externo). Após geração... / The dental implants have been widely used for rehabilitation of partial and complete edentulism using fixed and removable prostheses. Despite the success rate and predictability, failures are reported and commonly associated with biomechanical complications. Among the biomechanical factors, an adequate proportion between the implant and superstructure dimensions should be established. However, there is little information about the influence of crown height and lever arm on stress in cortical and trabecular bone. Although the use of implants has increased, many patients are limited by insufficient bone height. Thus, some implant systems developed short implants to avoid invasive surgical procedures. Nevertheless, such implants present an inverted crown/anchored area ratio. The present study will be divided into two chapters. The first one will evaluate the influence of three pre-established crown heights attached to external hexagon implants on all structures. In the second chapter, it will be evaluated the influence of the same crown heights attached to external hexagon and morse taper implants on the stress distribution in bone tissue. Initially, three 3D models were fabricated using the softwares SolidWorks 2006 and Rhinoceros 4.0. The software InVesalius (CTI, Sao Paulo, Brazil) was also used to generate the bone model through a computed tomography. Each model was composed by a bone block with an external hexagon implant (3.75 X 10.0 mm) (Conexao Sistemas de Protese, Sao Paulo) and a crown with different heights (10 mm, 12.5 mm and 15 mm) attached to the implant platform (external hexagon). After generation of the geometries, the models were imported to the software FEMAP 10.0 (Siemens PLM Software Inc., USA) for pre- and post-processing of finite elements to generate the meshes as well as the loading and boundary conditions. Axial load of 200N and oblique load of 100N were ... (Complete abstract click electronic access below)
14

Análise das tensões nos primeiros pré-molares superior e inferior, em contato, através do método de elementos finitos / Enamel stress distribution in superior and inferior premolars, in contact, through a finit elements study

Alexandre Carvalho Teixeira 22 February 2006 (has links)
As lesões cervicais não cariosas foram, durante muito tempo, atribuídas à abrasão causada pela escovação dental, e/ou por processos erosivos. Teorias biomecânicas consideram a possibilidade de que concentrações de tensões na região cervical, causadas pela flexão de cúspides, poderiam contribuir, associadas a outros fatores clínicos, para o desenvolvimento dessas lesões chamadas de abfração O presente trabalho pretende através do método de elementos finitos, utilizando o programa ANSYS versão 8.1, analisar a distribuição de tensões na região cervical de modelos bidimensionais parametrizados dos primeiros prémolares superior e inferior quando estes são colocados em contatos cêntrico e excêntricos no plano frontal, sob uma carga de 1 N. Para simulação da diminuição da mobilidade do ligamento periodontal sob cargas de impacto, o valor real do seu módulo de elasticidade foi aumentado para o correspondente ao do osso esponjoso e ao do osso cortical. Os resultados permitiram concluir que, de uma maneira geral, nas posições excêntricas, os dentes se flexionam e tensões de tração ocorrem na região cervical oposta ao contato com valores compatíveis para formação das lesões. Na posição cêntrica, as tensões de tração se manifestam mais na região da fossa central de ambos os dentes e na cervical do pré-molar inferior. A simulação da diminuição da mobilidade dentaria sob cargas de impacto reduziu o valor das tensões de tração, em todas as regiões analisadas, na ordem de 33% para o pré-molar superior e 66% para o inferior, mas não alterou seu padrão de distribuição. / Non carious cervical lesions were often attributed to toothbrush abrasion and/or erosive process. Biomechanical theories consider that stress concentration in the cervical area, caused by cuspal flexure, may contribue, associated to other clinical factors for the development of the lesion called abfraction. The aim of this finite element study, using the ANSYS version 8.1, is to analyze the stress distribution in the cervical region of superior and inferior premolars bidimensional models. Contacts in centric and eccentric positions were reproduced under a 1 N load. To simulate tooth mobility reduction under impact loads, the elastic modulus of the periodontal ligament was increased to reach the corresponding ones of the alveolar and cortical bone. The results showed that, in eccentric positions, teeth bend and tensile stress are generated at the cervical region opposed to the contact side, justifying the possibility to initiation of the lesion. In centric position, tensile stress occurred on both teeth at the central fossae and at the buccal cervical area of the inferior premolar. The simulation of tooth mobility reduction under impact loads diminished the tensile stress value, at all of the analyzed positions, in a rate of 33% and 66% respectively to superior and inferior premolars.
15

Análise da distribuição das tensões em maxila submetida à expansão cirurgicamente assistida com aparelho ósseo-suportado / Analysis of the distribution of maxillary stresses submitted to surgically assisted maxillary expansion with a bone-supported device

Victor Tieghi Neto 22 June 2017 (has links)
A expansão de maxila cirurgicamente assistida (EMCA) é a modalidade de tratamento que tem como objetivo romper as regiões de reforço maxilar permitindo seu movimento expansivo gradativamente. Tal movimento pode ser realizado às custas de aparelhos dento-suportado, dento-muco-suportado, implanto-suportados ou ósseo-suportado. Os efeitos produzidos pelo tratamento vão desde alterações esqueléticas (aumento da base, cavidade e do espaço aéreo nasais) até inclinações dentárias (principalmente nos dentes de suporte do aparelho expansor), dentre outras. O objetivo desta pesquisa foi avaliar, por meio do Método de Elementos Finitos (MEF), a distribuição das tensões produzidas pela EMCA nas estruturas maxilares utilizando-se aparelho expansor ósseo-suportado. Material e métodos: Foi confeccionado um modelo tridimensional de maxila para simulação da EMCA com osteotomia tipo LeFort I descendente sem degrau, com disjunção pterigomaxilar utilizando um modelo de aparelho ósseo-suportado para o teste com a simulação de abertura de 1mm. Os resultados mostraram maior abertura da maxila na região anterior de incisivos a pré-molar (1 mm) e em menor quantidade (0,6mm) na região de molares. A tensão máxima principal (TMXP) mostrou a concentração de tensões principalmente em toda face palatina da maxila de pré-molar ao túber maxilar. Pela face lateral, ficou mais evidente a TMXP nas região de osso alveolar posterior ao pré-molar, molares e túber, assim como na região de pilar zigomático acima da osteotomia. Pelo plano transversal foi possível observar a transmissão de tensões ao longo das estruturas ósseas mostrando pouca dissipação para as raízes do molar. Enquanto que as forças de compressão (Tensão Mínima Principal), evidenciadas pela tensão mínima principal, se manifestaram nas áreas de pilar zigomático e adjacentes as osteotomias, assim como na áreas de contato do apoio do aparelho com o osso palatino. Tensões de tração e compressão também foram evidenciadas na região de processo pterigoide. A análise de tensão de Von Mises mostrou que a parte que mais sofre estresse é a haste que liga o módulo do aparelho com a plataforma de apoio. Conclusão: Houve maior abertura da maxila na região anterior e as tensões resultantes de forças transmitidas ao osso alveolar dos dentes adjacentes ao aparelho, parecem não ser suficientes para deslocar os dentes. / Surgically assisted maxillary expansion (SARME) is the modality of treatment that aims to weaken the points of maxillary reinforcement allowing its gradual expansion. Such movement can be performed at the expense of dento-supported, dento-muco-supported, implanto-supported or bony-backed devices. The effects produced by the treatment range from skeletal changes (increase of nasal base, cavity and nasal air space) to dental inclinations (mainly in the supporting teeth of the expander apparatus), among others. The objective of the present research was to evaluate the distribution of stress produced by SARME in the maxillary structures using the bone-supported expander apparatus by the Finite Element Method (FEM). Material and methods: A three-dimensional hemi-maxilla model was simulated for SARME with a non-step descending LeFort I osteotomy with pterygomaxillary disjunction using a bone-supported device model for the 1mm aperture simulation test. The results showed a greater opening of the maxilla in the anterior region of the incisors to the premolar (1 mm) and smaller (0.6 mm) in the molar region. The principal maximal stress (TMXP) showed the concentration of the tension forces mainly in all the palatine face of the pre-molar maxilla to the maxillary tuft. Due to the lateral aspect, the TMXP was more evident in the posterior alveolar bone region, the molars and tuber, as well as in the epilating zygomatic region above the osteotomy. From the transversal plane, it was possible to observe the transmission of stress along the bony structures showing little dissipation for the roots of the molar. Meanwhile, the forces of compression (Principal Minimum Tension) evidenced by the principal minimal stress, were manifested in the areas of the zygomatic pillar adjacent to the osteotomies, as well as in the areas of contact of the support of the apparatus with the palatine bone. Tension and compression forces were also evidenced in the pterygoid process region. Von Mises\' stress analysis showed that the most stressed part is the rod connecting the device module to the support platform. Conclusion: There was a greater opening of the maxilla in the anterior region and the resulting forces of tension transmitted to the alveolar bone of the teeth adjacent to the appliance did not seem to be sufficient to displace the teeth.
16

"Influência da esplintagem de restaurações protéticas fixas e do número de implantes na distribuição de tensões em mandíbula edentada posterior - análise em elementos finitos" / Influence of the splinting of fixed prosthetic restorations and the number of implants on stress distribution in posterior edentulous mandible – finite element analysis

Marcelo Gomes da Silva 06 June 2005 (has links)
Em casos de edentulismo parcial, especialmente na ausência de três ou mais dentes posteriores contíguos, não há consenso sobre o número ideal de implantes a serem utilizados nem sobre a conveniência biomecânica de unir ou não as coroas protéticas. O presente estudo teve como finalidade analisar a influência da esplintagem de restaurações protéticas fixas e do número de implantes na distribuição das tensões de von Mises em modelos matemáticos bidimensionais obtidos pelo método de elementos finitos. A partir da imagem digitalizada de uma peça anatômica real, correspondente ao corte sagital da porção posterior esquerda de uma mandíbula, três modelos foram desenvolvidos com as seguintes configurações: (1) coroas protéticas isoladas sobre três implantes; (2) coroas protéticas esplintadas sobre três implantes; e (3) prótese parcial fixa sobre dois implantes, com um pôntico intermediário. Uma carga estática de 300N foi dividida, com igual magnitude, por 15 áreas de aplicação nas superfícies oclusais e angulada em 15º em relação ao longo eixo das restaurações. Os resultados mostraram que o modelo com coroas esplintadas sobre três implantes apresentou os menores valores de tensão, enquanto os maiores valores de tensão foram encontrados no modelo com coroas isoladas. O limite de proporcionalidade dos materiais e estruturas analisadas não foi alcançado nos três modelos, fato que não contra-indicou nenhuma das configurações estudadas. Entretanto, os resultados sugeriram que o planejamento do tratamento deve ser adequado a condições anatômicas, oclusais e biomecânicas específicas. / In cases of partial edentulism, specially in the absence of three or more contiguous posterior teeth, there is not a consensus about the ideal number of implants nor the biomechanical convenience of splinting or not prosthetic crowns. The aim of the present study was to analyze the influence of the splinting of fixed prosthetic restorations and the number of implants on von Mises stress distribution within mathematical two-dimensional models obtained from finite element method. From the digitalized image of a real anatomical piece, corresponding to the sagital slice of the left posterior portion of a mandible, three models were constructed in the following configurations: (1) non-splinted prosthetic crowns on three implants; (2) splinted prosthetic crowns on three implants; and (3) fixed partial denture on two implants, with an intermediate pontic. A 300N static load was divided, in equal magnitude, by 15 application areas on occlusal surfaces and angled in 15º in relation to the long axis of the restorations. The results showed that the model with splinted crowns on three implants presented the lowest stress values, whereas the highest stress values were found in the model with non-splinted crowns. The proportional limit of the analyzed materials and structures was not reached in the three models, fact that did not contraindicate any studied configuration. However, the results suggested that treatment planning may be adequate to anatomical, occlusal and biomechanical specific conditions.
17

A INFLUÊNCIA DO ALAGAMENTO APICAL NA DISTRIBUIÇÃO DE TENSÕES EM CANAIS RADICULARES CURVOS: ANÁLISE DE ELEMENTOS FINITOS / THE INFLUENCE OF APICAL ENLARGEMENT ON STRESS DISTRIBUTIONS IN CURVED ROOTS CANALS: FINITE ELEMENT ANALYSIS

Lang, Pauline Mastella 15 August 2013 (has links)
Localized irregularities in the canal walls are sities which concentrate stresses and make the stresses distribution occurs asymmetrically in the root structure during the filling phase. This asymmetric distribution of stresses may contribute to the generation of defects in the dentin, which can propagate in vertical root fracture (VRF). Thus, this study evaluated the influence of enlargement in the apical stress distribution in curved canals when a spreader digital was inserted against the canal walls using Finite Element Analysis (FEA). A basic three-dimensional geometric model of the mesiobuccal root (MV) of a Maxillary First Molar (1ºMM) with root canal curved and anatomical diameter 0.25 mm was confectioned with the program SolidWorks Simulation (Dassault Systèmes SolidWorks Corporation, France). Based on this basic model, four post-instrumentation geometric models were established to accommodate canal preparation performed with HERO 642 (Micromega, Besançon, France) instruments 30/.02 (IAF +1); 35/.02 (IAF +2); 40/.02 (IAF +3) and 45/.02 (IAF +4). In the program SolidWorks Simulation, the models were discretized in a finite number of elements united by their nodal points. To the models were attributed to mechanical properties of dentin that characterized their mechanical behavior. The models were fixed to the outer surface to limit the rotational and translational movements in all directions during the simulation. A load of 13 N was applied along the canal walls (mesial, distal, buccal and palatal) up to 3 mm of the apical foramen simulating the action of a spreader digital Nickel-Titanium (NiTi) B Dentsply Maillefer, Ballaigues, Switzerland). The results of AEF showed a better distribution of stresses as further enlargement was performed. The highest stress decreased distal and palatal walls of the canal because of the increased apical enlargement. The location of the highest value of stress changed in the buccal and palatal walls due to increased apical enlargement. Thus, it can be concluded that the enlargement apical improve the distribution of stresses in curved canals when a digital spreader is inserted against the walls of the canal. / Irregularidades presentes nas paredes do canal radicular são sítios que concentram tensões, e fazem com que a distribuição de tensão ocorra de maneira assimétrica na estrutura radicular durante a etapa obturadora. Essa distribuição assimétrica de tensões talvez contribua para a geração de defeitos na dentina radicular, os quais podem propagar-se em Fratura Vertical da Raiz (FVR). Diante disso, este estudo avaliou a influência do alargamento apical na distribuição de tensões em canais radiculares curvos quando um espaçador digital foi inserido contra as paredes do canal utilizando a Análise de Elementos Finitos (AEF). Um modelo geométrico tridimensional básico da raiz Mésio-Vestibular (MV) de um Primeiro Molar Superior (1ºMS) com canal radicular curvo e diâmetro anatômico 0,25 mm foi confeccionado com o programa SolidWorks Simulation (Dassault Systèmes SolidWorks Corporation, França). Baseado nesse modelo básico, quatro modelos geométricos pós-instrumentação foram estabelecidos para acomodar o preparo do canal realizado com instrumentos HERO 642 (Micromega, Besançon, França) 30/.02 (IAI+1); 35/.02 (IAI+2); 40/.02 (IAI+3) e 45/.02 (IAI+4). No programa SolidWorks Simulation, os modelos foram discretizados em um número finitos de elementos unidos por seus pontos nodais. Aos modelos foram atribuídas propriedades da dentina (módulo de elasticidade, coeficiente de Poisson e densidade) a fim de caracterizar o seu comportamento mecânico. Então, os modelos foram fixados na superfície externa para limitar os movimentos de rotação e translação em todas as direções durante a simulação. Uma força de 13 N foi aplicada ao longo das paredes do canal radicular (mesial, distal, vestibular e palatina) até 3 mm do forame apical simulando a ação de um espaçador digital B de Níquel-Titânio (NiTi) (Dentsply Maillefer, Ballaigues, Suíça). Os resultados da AEF mostraram que houve uma melhor distribuição de tensões à medida que um maior alargamento foi realizado. O maior valor de tensão diminuiu nas paredes distal e palatina do canal em virtude do maior alargamento apical. O local aonde a tensão foi maior, mudou nas paredes vestibular e palatina, de 6 mm para 3 mm, em decorrência do maior alargamento apical. Dessa forma, pode-se concluir que o alargamento apical melhora a distribuição de tensões em canais radiculares curvos quando um espaçador digital é inserido contra as paredes do canal.
18

Estudo biomecânico de conexões implante/pilar com parafusos convencionais e parafusos modificados tipo Cone Morse: análise tridimensional pelo método dos elementos finitos / Biomechanical study of implant/abutment connections with conventional screws and modified Morse Taper screws: three-dimensional analysis by finite element method.

Pita, Murillo Sucena 19 April 2013 (has links)
Apesar da confiabilidade e das altas taxas de sucesso relacionadas aos tratamentos com implantes, falhas das reabilitações protéticas ainda são persistentes, especialmente o afrouxamento dos parafusos de retenção dos pilares. A aplicação de um torque, que gere uma pré-carga no mesmo, tem sido o seu principal meio de prevenção, embora não tenha sido capaz de eliminá-lo completamente. A natureza do afrouxamento é complexa, e os mecanismos responsáveis pelas falhas mecânicas dos parafusos de conexão dos sistemas de implantes não estão totalmente elucidados. Modificações nos modelos das conexões protéticas e dos parafusos de retenção vêm sendo desenvolvidas com o intuito de resolver essa intercorrência. Porém, a literatura relativa à configuração ideal destas modificações biomecânicas e seus fatores determinantes envolvidos ainda é inconclusiva. Assim, o objetivo do presente do estudo foi avaliar por meio da análise tridimensional de elementos finitos, a distribuição de tensões em dois diferentes sistemas de implantes, hexágono externo (HE) e triângulo interno (TI), com parafusos de retenção de pilares planos convencionais e parafusos modificados tipo Cone Morse, estabelecendo-se qualitativamente os mapas de tensões e quantitativamente os valores de pré-carga diante do torque e de carregamentos axiais e oblíquos pré-estabelecidos. Os resultados evidenciaram que, para todos os modelos, os carregamentos externos não exerceram influência sobre os valores das tensões de von Mises e da pré-carga, e que as tensões mais elevadas concentraram-se especificamente na haste dos parafusos. A conexão TI apresentou-se biomecanicamente mais favorável do que a conexão HE, com distribuição mais homogênea de tensões ao longo do conjunto implante/pilar/parafuso. Adicionalmente, os parafusos planos convencionais apresentaram, significativamente, menores tensões e valores de pré-carga superiores aos parafusos modificados tipo Cone Morse, portanto estes últimos revelaram-se mais susceptíveis a falhas mecânicas como o afrouxamento e/ou fratura. / Despite the reliability and high success rates related to treatment with implants, prosthetic rehabilitation failures are still persistent, especially the loosening of the screws holding the abutments. Applying a torque, which generates a preload on the screw, has been its primary means of prevention, although not being able to eliminate it completely. The nature of loosening is complex, and the mechanisms responsible for mechanical failure of the screw connecting the implant systems are not fully elucidated. Changes in designs of connections and prosthetic retaining screws have been developed in order to solve this complication. However, the literature on the optimal configuration of these changes and their biomechanical factors involved is still inconclusive. The objective of this study was to evaluate through three-dimensional finite element analysis, the stress distribution in two different implant systems, external hexagon (EH) and internal triangle (IT), with conventional plan screws and modified Morse Taper screws, establishing up qualitatively the stress maps and quantitatively the values of preload in front of the torque and of pre-established axial and oblique loads. The results showed that, for all models, the external loads exerted no influence on the values of von Mises stress and preload, and that the higher stresses have focused specifically on the spindle of the screws. The IT connection appeared biomechanically more favorable than the EH, with more homogeneous distribution of stresses throughout the whole implant/abutment/screw. Additionally, conventional screws showed significantly lower stress values and higher preload than the modified Morse Taper screws, then, this latter proved to be more susceptible to mechanical failures as loosening and/or fracture.
19

Estudo biomecânico de conexões implante/pilar com parafusos convencionais e parafusos modificados tipo Cone Morse: análise tridimensional pelo método dos elementos finitos / Biomechanical study of implant/abutment connections with conventional screws and modified Morse Taper screws: three-dimensional analysis by finite element method.

Murillo Sucena Pita 19 April 2013 (has links)
Apesar da confiabilidade e das altas taxas de sucesso relacionadas aos tratamentos com implantes, falhas das reabilitações protéticas ainda são persistentes, especialmente o afrouxamento dos parafusos de retenção dos pilares. A aplicação de um torque, que gere uma pré-carga no mesmo, tem sido o seu principal meio de prevenção, embora não tenha sido capaz de eliminá-lo completamente. A natureza do afrouxamento é complexa, e os mecanismos responsáveis pelas falhas mecânicas dos parafusos de conexão dos sistemas de implantes não estão totalmente elucidados. Modificações nos modelos das conexões protéticas e dos parafusos de retenção vêm sendo desenvolvidas com o intuito de resolver essa intercorrência. Porém, a literatura relativa à configuração ideal destas modificações biomecânicas e seus fatores determinantes envolvidos ainda é inconclusiva. Assim, o objetivo do presente do estudo foi avaliar por meio da análise tridimensional de elementos finitos, a distribuição de tensões em dois diferentes sistemas de implantes, hexágono externo (HE) e triângulo interno (TI), com parafusos de retenção de pilares planos convencionais e parafusos modificados tipo Cone Morse, estabelecendo-se qualitativamente os mapas de tensões e quantitativamente os valores de pré-carga diante do torque e de carregamentos axiais e oblíquos pré-estabelecidos. Os resultados evidenciaram que, para todos os modelos, os carregamentos externos não exerceram influência sobre os valores das tensões de von Mises e da pré-carga, e que as tensões mais elevadas concentraram-se especificamente na haste dos parafusos. A conexão TI apresentou-se biomecanicamente mais favorável do que a conexão HE, com distribuição mais homogênea de tensões ao longo do conjunto implante/pilar/parafuso. Adicionalmente, os parafusos planos convencionais apresentaram, significativamente, menores tensões e valores de pré-carga superiores aos parafusos modificados tipo Cone Morse, portanto estes últimos revelaram-se mais susceptíveis a falhas mecânicas como o afrouxamento e/ou fratura. / Despite the reliability and high success rates related to treatment with implants, prosthetic rehabilitation failures are still persistent, especially the loosening of the screws holding the abutments. Applying a torque, which generates a preload on the screw, has been its primary means of prevention, although not being able to eliminate it completely. The nature of loosening is complex, and the mechanisms responsible for mechanical failure of the screw connecting the implant systems are not fully elucidated. Changes in designs of connections and prosthetic retaining screws have been developed in order to solve this complication. However, the literature on the optimal configuration of these changes and their biomechanical factors involved is still inconclusive. The objective of this study was to evaluate through three-dimensional finite element analysis, the stress distribution in two different implant systems, external hexagon (EH) and internal triangle (IT), with conventional plan screws and modified Morse Taper screws, establishing up qualitatively the stress maps and quantitatively the values of preload in front of the torque and of pre-established axial and oblique loads. The results showed that, for all models, the external loads exerted no influence on the values of von Mises stress and preload, and that the higher stresses have focused specifically on the spindle of the screws. The IT connection appeared biomechanically more favorable than the EH, with more homogeneous distribution of stresses throughout the whole implant/abutment/screw. Additionally, conventional screws showed significantly lower stress values and higher preload than the modified Morse Taper screws, then, this latter proved to be more susceptible to mechanical failures as loosening and/or fracture.
20

Análise não-linear do mecanismo de cimentação de pinos intra-radiculares utilizando o método dos elementos finitos / NO-LINEAR ANALYSIS OF CEMENTATION MECHANISM IN ROOT POSTS USING THE FINITES ELEMENTS METHOD

Franco, Ana Paula Gebert de Oliveira 26 February 2008 (has links)
Made available in DSpace on 2017-07-24T19:22:08Z (GMT). No. of bitstreams: 1 Ana Paula Gebert.pdf: 9068136 bytes, checksum: 8f06dbf649af9345afc6e09a57f71fb6 (MD5) Previous issue date: 2008-02-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim is to analyze a non-linear mechanism of the cementation of root posts considering the existence of gaps in cement-dentin and cement-post interfaces analyzing the correlation of mechanical test and computational model. Were selected 15 mandibular pre-molars, to receive root posts Exacto (Angelus®/Londrina - Brazil) fixed with chemical resin cement Cement-Post (Angelus®/Londrina - Brazil). The teeth were termocycled, radiographed and cuted themselves getting cervical, middle and apical discs of roots. These discs were treated and molded with addition of silicone and epoxy resin replics was obtained before and after the compression test (220 N-0, 2 mm / min). The replics were analyzed in MEV to observe the formation of gaps at the interfaces on the upper surfaces of the specimens, which were measured in the Image Tool program. For statistical analysis of the comparison between the mensures of gaps (μm) in the interface was used in the Wilcoxon test which showed that there were statistical differences between groups (p <0.0001). In the comparison between the mensures of gaps in the same interface of the cervical, middle and apical discs before and after the compression test, there was no statistically significant difference (p = 0.4304) and (p = 0.7766), respectively. In cement-post interface there was no gaps in most specimens. The dentin discs were photographed and their images obtained from three-dimensional models simulating the compression test using the Finite Elements Method, considering linear-elastic material with values of module of elasticity and Poisson's coefficient, and obtained in the mechanical test of the traction, compression and bending resistance in the post and/or the cement. There was the Poisson's effect and a low stress concentration in dentin-cement and cement-post interfaces promoted by the force application, geometry and materials properties. In assessing the match of the mechanical test with the computational model, met a difference because of the consideration of perfect adhesion in computational model of the cervical and middle discs, which does not occur clinically, as there was formation of gaps in some root regions of the dentin discs. The apical discs were modeled like non-linear and it was considered an area of contact between the faces. / O objetivo é analisar de forma não-linear o mecanismo de cimentação de pinos intra-radiculares considerando a existência das fendas nas interfaces dentina-cimento-pino analisando a correspondência do ensaio mecânico e modelo computacional. Foram selecionados 15 pré-molares inferiores, para receber pinos intra-radiculares Exacto (Angelus®/Londrina - Brasil) fixados com cimento resinoso autopolimerizável Cement-Post (Angelus®/Londrina - Brasil). Os dentes foram termociclados, radiografados e cortados obtendo-se discos cervicais, médios e apicais das raízes. Esses discos foram tratados e moldados com silicone de adição e obtidas réplicas de resina epoxi antes e após o ensaio de compressão (220 N-0,2 mm/min). As réplicas foram analisadas em MEV para observar a formação de fendas nas interfaces nas faces superiores dos espécimes, as quais foram medidas no programa Image Tool. Para análise estatística da comparação entre as medidas de fendas (μm) na interface foi utilizado o teste Wilcoxon que demonstrou que houve diferenças estatísticas entre os grupos (p < 0,0001). Na comparação entre as medidas de fendas da mesma interface dos discos cervical, médio e apical antes e depois do ensaio de compressão, não houve diferenças significantes estatisticamente (p = 0,4304) e (p = 0,7766), respectivamente. Na interface cimento-pino observou-se ausência de fendas na maior parte dos espécimes. Os discos de dentina foram fotografados e a partir de suas imagens obtidos modelos tri-dimensionais analisados simulando-se o ensaio de compressão por meio do Método dos Elementos Finitos, considerando material elástico-linear com valores de módulo de elasticidade e Coeficiente de Poisson e, obtidos de ensaios mecânicos de resistência à tração, compressão e flexão realizados no pino e/ou no cimento. Observou-se o efeito Poisson e que houve uma concentração leve de tensões nas interfaces dentina-cimento e cimento-pino promovidas pela forma de aplicação da força, geometria e propriedades dos materiais. Na avaliação da correspondência do ensaio mecânico com o modelo computacional, encontrou-se uma diferença devido à consideração de adesão perfeita no modelo computacional dos discos cervicais e médios, o que não ocorre clinicamente, visto que houve formação de fendas em algumas regiões radiculares dos discos de dentina. Os discos apicais foram modelados de maneira não-linear, considerando-se uma superfície de contato entre as faces.

Page generated in 0.2798 seconds