• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influência do sistema de cimentação adesiva e da fonte de luz fotoativadora na resistência à extrusão de pinos de fibra de vidro

Lima, Luiz Rafael Calixto [UNESP] 03 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-03Bitstream added on 2014-06-13T18:51:40Z : No. of bitstreams: 1 lima_lrc_me_arafo.pdf: 301269 bytes, checksum: e249a410590b65d0ca0f202c5160930d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A retenção de pinos pré-fabricados de fibra de vidro, utilizados na restauração de dentes com tratamento endodôntico, é baseada na sua união às superfícies das paredes do canal radicular, por meio dos agentes de fixação resinosos. O tipo de pino utilizado, assim como a fonte de luz fotoativadora do cimento, também pode influenciar nessa retenção, principalmente nas regiões mais críticas do canal, como o terço apical, onde há uma grande dificuldade de acesso dessa luz ativadora. Assim, o propósito deste trabalho foi avaliar comparativamente a influência de diferentes sistemas de cimentação (químico convencional; dual convencional, químico com adesivo auto-condicionante, dual com adesivo auto-condicionante e cimento dual auto-adesivo), na resistência à extrusão (push-out) de pinos de fibra de vidro, nos diferentes terços do canal (cervical, médio, aplical). Foi avaliada também a influência do tipo de fonte de luz fotoativadora do cimento: luz halógena (Optilux 501) e LED (Ultraled). O tipo de falha foi avaliado através de microscopia. Foram utilizadas 240 unidades experimentais, em forma de discos, com aproximadamente 1 mm de espessura, retirados de 80 raízes bovinas, restauradas com retentores intraradiculares. Foi utilizada uma máquina de ensaios universais, MTS 810 Material Test System, à velocidade de 0,5 mm/min-1, com célula de carga de 50 Kg, para avaliação da resistência push-out nos diferentes terços de cada corpo-de-prova. Os valores de resistência em kgf, foram convertidos para MPa e analisados por meio de Análise de Variância e teste de Tukey, com nível de significância de 5%. Os resultados mostraram baixos valores de retenção para os grupos com os cimentos autoadesivos,independente da fonte de luz utilizada. Os cimentos de condicionamento ácido total e os de adesivos auto-condicionantes parecem ser opções viáveis no processo... / The retention of prefabricated glass fiber posts, used for the restoration of endodontically-treated teeth, is based on adhesive systems and resin luting cements. The type of posts used, as well as the type of activation of the cement can also influence this retention, mainly in more critical areas of the radicular dentin, such as the apical root segments, where there is a great difficult access of the light curing units. Thus, the purpose of this study was to evaluate the influence of different resin cements (Chemical-cure total-etch; dual-cure total-etch; chemicalcure and self-etch bonding system, dual-cured and self-etch bonding system; and dual-cure self-adhesive cement) on the bond strength (push-out) of glass fiber posts on the different thirds of the root (cervical, middle and apical). The influence of the light curing unit was evaluated by halogen LCU (Optilux 501) and by LED LCU (LEC II 470) use. The failure mode was evaluated by stereoscopic microscope. Disks of the samples (n=240) were used, with approximately 1 mm of thickness of 80 bovine roots restored with glass fiber posts. A universal testing machine (MTS 810 Material Test System) was used with a 1 mm diameter steel rod at cross-head speed of 0,5 mm/min until post extrusion, with load cell of 50 kg, for evaluation of the push-out strength in different thirds of each sample. The pushout strength values in kgf were converted to MPa and analyzed through Analysis of Variance and Tukey’s test, with significant level of 5%. The results of the present study showed that the self-adhesive cements group resulted in low retention values, in every light source utilized. The total-etch cements and the self-etch bonding systems seem to be a viable alternative in the glass fiber posts cementation process, with either halogen light or LEDs.
2

Avaliação de núcleo metálico fundido, núcleo com fibra de vidro e endocrown em cerâmica: análise comparativa pelo método dos elementos finitos

Rossato, Desirée Mory [UNESP] 23 March 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-03-23Bitstream added on 2014-06-13T19:20:24Z : No. of bitstreams: 1 rossato_dm_dr_arafo.pdf: 3020954 bytes, checksum: 1a5b7cd1dca8b24d2c32a870ea1c52b3 (MD5) / Dentes tratados endodonticamente têm uma maior incidência a fraturas, tornando sua restauração um desafio para a Odontologia. Foram selecionados três incisivos centrais superiores humanos os quais foram restaurados com núcleo metálico fundido e coroa de cerâmica IPS emax®Press, núcleo de preenchimento em resina ccomposta associado ao pino de fibra de vidro e coroa de cerâmica IPS emax®Press e endocrown em cerâmica IPS emax®Press. Os dentes foram levados ao teste estático de fratura. Paralelamente foi realizado um modelo virtual de um incisivo central que apresentava características e restaurações representativas dos dentes que foram levados ao teste de fratura. A análise computacional pelo método dos elementos finitos 3D foi realizada. Os resultados obtidos nos dois tipos de análise realizada mostram que a coroa endocrown e o pino de fibra de vidro apresentaram um padrão de fratura que não afetou a estrutura radicular enquanto que o núcleo metálico fundido apresentou um padrão de fratura desfavorável envolvendo a estrutura radicular condenando o dente. Na análise dos elementos finitos obtivemos uma correta previsibilidade de onde as coroas e núcleos poderiam falhar. A análise dos elementos finitos é uma metodologia importante na análise de novas técnicas e novos materiais. / Restoration of endodontically treated teeth is a common problem in restorative dentistry, related to the fractures occurring in such teeth. Three human maxillary central incisor were selected and restaured with metal core and IPS emax®ceramic crown, glass fiber post with composite core and IPS emax®ceramic crown and IPS emax®ceramic endocrown. Static loading test were performed on each specimen until failure. Paralleled a 3D model of a maxillary central incisor is presented. The same characteristics of the real teeth used in the mechanical test were applied. A 3D finite elements analysis was made. The results of both analysis shows that endocrown and fiber post have a pattern of fracture that not involve the root while metal core presents a catastrophic pattern of fracture in the root. The FEM analysis is an important methodology in the development of new materials.
3

Avaliação de núcleo metálico fundido, núcleo com fibra de vidro e endocrown em cerâmica : análise comparativa pelo método dos elementos finitos /

Rossato, Desirée Mory. January 2010 (has links)
Orientador: José Roberto Cury Saad / Banca: Pedro Yoshito Noritomi / Banca: Luiz Alberto Plácido Penna / Banca: Edson Alves de Campos / Banca: Celso Luiz de Angelis Porto / Resumo: Dentes tratados endodonticamente têm uma maior incidência a fraturas, tornando sua restauração um desafio para a Odontologia. Foram selecionados três incisivos centrais superiores humanos os quais foram restaurados com núcleo metálico fundido e coroa de cerâmica IPS emax®Press, núcleo de preenchimento em resina ccomposta associado ao pino de fibra de vidro e coroa de cerâmica IPS emax®Press e endocrown em cerâmica IPS emax®Press. Os dentes foram levados ao teste estático de fratura. Paralelamente foi realizado um modelo virtual de um incisivo central que apresentava características e restaurações representativas dos dentes que foram levados ao teste de fratura. A análise computacional pelo método dos elementos finitos 3D foi realizada. Os resultados obtidos nos dois tipos de análise realizada mostram que a coroa endocrown e o pino de fibra de vidro apresentaram um padrão de fratura que não afetou a estrutura radicular enquanto que o núcleo metálico fundido apresentou um padrão de fratura desfavorável envolvendo a estrutura radicular condenando o dente. Na análise dos elementos finitos obtivemos uma correta previsibilidade de onde as coroas e núcleos poderiam falhar. A análise dos elementos finitos é uma metodologia importante na análise de novas técnicas e novos materiais. / Abstract: Restoration of endodontically treated teeth is a common problem in restorative dentistry, related to the fractures occurring in such teeth. Three human maxillary central incisor were selected and restaured with metal core and IPS emax®ceramic crown, glass fiber post with composite core and IPS emax®ceramic crown and IPS emax®ceramic endocrown. Static loading test were performed on each specimen until failure. Paralleled a 3D model of a maxillary central incisor is presented. The same characteristics of the real teeth used in the mechanical test were applied. A 3D finite elements analysis was made. The results of both analysis shows that endocrown and fiber post have a pattern of fracture that not involve the root while metal core presents a catastrophic pattern of fracture in the root. The FEM analysis is an important methodology in the development of new materials. / Doutor
4

Influência do modo de aplicação e viscosidade do ácido fosfórico 37% na adesão de pinos de fibra de vidro em condutos radiculares

Scholz, Maria Fernanda Costa 23 February 2018 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-07-31T17:05:16Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Maria Fernanda Costa Scholz.pdf: 1290758 bytes, checksum: ddb5c2c0ca43f593268a067c13b5296b (MD5) / Made available in DSpace on 2018-07-31T17:05:16Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Maria Fernanda Costa Scholz.pdf: 1290758 bytes, checksum: ddb5c2c0ca43f593268a067c13b5296b (MD5) Previous issue date: 2018-02-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo do presente estudo foi avaliar a influência da viscosidade do ácido fosfórico e do modo de aplicação nos valores de resistência de união de pino de fibra de vidro cimentados na dentina radicular através do teste de pushout. Raízes de 32 pré-molares foram preparadas endodonticamente e divididas em 4 grupos (n = 8) de acordo com a combinação dos seguintes fatores: viscosidade do ácido e forma de aplicação. Após aplicação do adesivo Universal no interior dos condutos, foram realizadas as cimentações dos pinos com o cimento resinoso RelyX ARC. Em seguida, as raízes foram seccionadas transversalmente em 6 fatias de aproximadamente 1 mm e o teste de push-out foi realizado a uma velocidade de 0,5 mm/min. Os resultados de resistência de união foram submetidos a uma análise de variância de três fatores de medidas repetidas e teste de Tukey (alpha = 0.05). A interação dupla modo de aplicação vs. viscosidade do ácido (p = 0,0002) e o terço radicular (p < 0,0001) foram estatisticamente significantes. O maior valor de resistência de união foi observado no grupo condicionado com ácido fosfórico líquido sob o modo de aplicação sônica (p < 0,05) sendo todos os outros grupos semelhantes entre si. Quanto ao terço radicular, observou-se maior valor de resistência de união no terço cervical, seguido do terço médio e do terço apical terço apical (p < 0,05). Pelos resultados pode-se concluir que uma melhor adesão de pinos de fibra de vidro ao conduto radicular pode ser obtida através do condicionamento com ácido fosfórico líquido com aplicação sônica. / The aim of the present study was to evaluate the influence of the etchant viscosity (liquid or gel) and the application mode (passive or sonic) on the pushout bond strength values of fiberglass post to root dentin and the conditioning pattern on the smear-layer covered root dentin before cementation. The roots of premolars were prepared endodontically and divided into 4 groups (n = 8) according to the combination of the main factors: phosphoric acid viscosity (liquid gel) and application mode (passive or sonic). After the application of the universal adhesive into the root canals, the fiberglass posts were cemented with cementation system RelyX ARC. Then, the roots were sectioned transversely 6 slices of approximately 1 mm and the push-out test performed at a speed 0.5 mm/min. The results were submitted to a repeated measures three-way ANOVA and Tukey’s test (alpha = 0.05). The cross-product interaction mode of application vs. etchant viscosity (p = 0.0002) and the main factor root third (p < 0.0001) were statistically significant. The highest bond strength value was observed when the conditioning of the root canal was performed with a liquid phosphoric acid under sonic application mode (p < 0.05), being all other groups similar one another (p < 0.05). Regarding the root third, the highest push-out bond strength value was observed in the cervical third, followed by the medium third and the apical thirds (p < 0,05). The most common fracture pattern was the mixed failure. By the partial results one may conclude that a better bonding of fiberglass posts to root canals can be achieved when the conduits are conditioned with a
5

RESISTÊNCIA À FRATURA DE DENTES COM RAÍZES FRAGILIZADAS RESTAURADOS COM DIFERENTES RETENTORES INTRARRADICULARES / FRACTURE RESISTANCE OF WEAKENED ROOTS RESTORED BY DIFFERENT POST SYSTEMS

Broch, Juliana 02 March 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Taking into account the importance of developing techniques to restore teeth with excessively flared root canals, this study aimed to evaluate the effect of mechanical cycling on the fracture resistance of teeth with weakened roots, restored with different techniques, as well as to analyze the failure modes after fracture testing. Eighty (N=80) bovine lower incisors were selected and the coronal and cervical portions were sectioned to standardize the specimens length at 15 mm. The roots were endodontically treated and prepared to 10 mm in intracanal length. The cervical portion of the root inner surface (5 mm) was enlarged (removing the intracanal dentin) using a diamond drill (KG Sorensen #4138) to produce a radicular wall with 1 mm in thickness. The specimens were embedded with acrylic resin and the periodontal ligament was simulated with a polyether material. Afterwards, the specimens were randomly allocated in 4 intracanal restoring strategies: cast post and core; double-tapered glass fiber post with cervical emerging diameter of 1.8 mm; double-tapered glass fiber post with cervical emerging diameter of 2.2 mm; anatomic posts (fiber posts relined with composite resin). Each restoring method was assessed without or with mechanical cycling, applying the protocol as followed: angle of 45º, 37ºC temperature, load of 88N, frequency of 2.2 Hz, 1.000.000 load-pulses. All of the restored teeth received metal full crown (Ni-Cr). All the specimens were submitted to fracture resistance at 45º and at a cross-head speed of 0.5 mm/min. Two-way ANOVA and Tukey showed that the root post system (p < 0.0004), the mechanical cycling (p < 0.003) and the interaction between the factors (p < 0.02) were statistically significant. The restoring methods with fiber posts did not change after mechanical cycling. Its fracture strength values were similar to that from cast post and core. The anatomic post suffered degradation with the mechanical cycling (the values reduced after aging). Concerning the mode of failure, the most failure from groups restored with cast post and core were catastrophic while the others groups showed a predominance of repairable failures. / Diante da necessidade do desenvolvimento de técnicas capazes de restaurar adequadamente raízes com condutos alargados, este trabalho visou avaliar o efeito da ciclagem mecânica sobre a resistência à fratura de dentes com raízes fragilizadas e restaurados com diferentes retentores intrarradiculares, bem como analisar o padrão de falha destes dentes quando submetidos à carga compressiva. Foram utilizados para este estudo 80 incisivos inferiores bovinos, cujas raízes foram seccionadas em 15 mm de comprimento, tratadas endodonticamente e preparadas até 10 mm de profundidade. Os 5 mm cervicais dos canais radiculares destas raízes foram fragilizados com uma ponta diamantada (4138), de modo a gerar uma espessura de parede radicular de 1 mm. As raízes foram incluídas em resina acrílica autopolimerizável e o ligamento periodontal foi simulado com material elastomérico (poliéter). Após, as raízes foram distribuídas aleatoriamente em quatro sistemas de retentores intrarradiculares: núcleo metálico fundido, pino de fibra de vidro (pinos de dupla conicidade, 1,8 mm de diâmetro cervical), pino de fibra de vidro especial (pinos de dupla conicidade, 2,2 mm de diâmetro cervical) e pino anatômico. Cada um desses sistemas de retentores foi avaliado com e sem ciclagem mecânica, sendo o protocolo de ciclagem o seguinte: angulação de 45°, temperatura de 37°C, força de 88N, freqüência de 2,2 Hz, totalizando 1 milhão de ciclos; durante a mesma os espécimes dos grupos sem ciclagem mecânica ficaram armazenados em água destilada. Em todos os grupos, foram cimentadas coroas totais metálicas de Níquel-Cromo sobre o núcleo. Os corpos de prova de todos os grupos foram submetidos ao teste de resistência à compressão em uma inclinação de 45° e à velocidade de 0,5 mm/mim até ocorrer a falha. A análise de Variância seguida de Tukey mostrou que o tipo de retentor intrarradicular (p < 0,0004), a ciclagem mecânica (p < 0,003) e a interação entre ambos (p < 0,02), foram estatisticamente significantes. Os pinos de fibra de vidro mantiveram-se estáveis após a ciclagem mecânica, com valores de resistência à fratura similares aos núcleos metálicos fundidos. Somente pinos anatômicos sofreram degradação com a ciclagem, reduzindo significativamente os valores de resistência à fratura. Em relação ao padrão de falha, foram fraturas predominantemente irreversíveis nos grupos reconstruídos com núcleo metálico fundido, e nos demais, reversíveis.

Page generated in 0.1049 seconds